Loading...
HomeMy WebLinkAboutA18-0074_Approved Plans_1544484982.pdf 44 kl "I/4 4 iii; iiiii ,111 11. 7. 4 z X07 ler Vail Fire&Emergency Services 12/10/18 General Notes 1 Remove 4 existing smoke detectors and replace with two. 2 Remove four speaker strobes and replace with two. Office/Storage 3 Remove one pull station and relocate one pull station. ` >i(c 4 Keep early warning smoke detection due to sleeping � p� g ri Addressable Circuit-Typical quarters directlyabove retailEquipment List- FireAlarm Systemo )11.1.1.1.1.11WIMIMIMMIJ Quant. Symbol Device Manufacturer Part# space. 2 SmokeDetector Gamewell XP95-P 0 XX Ol R, HeatDetectorROR Gamewell XP95 T 4 Tap speakers at 4 watt. 1 Pull Station Gamewell MS95 g.;Ih1h11C; C; Ae �;> it Keep two speakers for voice lo ` mi 1 X Strobe System Sensor SCW _SLCAI IN r_SLC OU 1 SLC PROG intelligibility. XX SpkrMulti db System Sensor SPCWV g Y' Changing I n 2 SpeakerStrobe System Sensor SPSCWV _ XX V Flow Switch Gamewell PID-95 XX TamperSwitch Gamewell PID-95 XX ©- DuctDetector Gamewell XP95-PD Heat or Smoke XX - smoke+sounder base Gamewell B6SNDR Detector Base _a_ S P XX ®P smoke+heat combo Gamewell XP95-M 7II 3 3 XX low air Gamewell PID 95 0. ® ,■ XX PWR Aux.PowerSupply Gamewell GFPS-9 ®0 0 0 XX w Ansul Switch Gamewell PID 95 \IIIIIIftwoll XX SCE Signal Control Elem. Gamewell SCE-95 Heat or Smoke • Detector Base Sonnenalp Acme Alarm Company l i Circuit Specifications OP NAC 1- 14awg 2cond FPLR shielded fire wire class B style Y. ):(<(-.; NAC 2- 14awg 2cond FPLR fire wire class B style Y. SLC CKT-16 awg 4 cond FPLR fire wire class A style 6. 1 I:o� a— No. Revision/Issue Date ,, Prepared by: B a p — , IL, . Wiring for Speaker— Strobes V` Retail 14 awg 2cond shielded FPLR / NIcET\o R k44 r++ `� */ Level IV )1=4) .0 Y c OP v 4 _ o cam# �pD� C r+ - u/, + Clint Bartels,SET oc A — o System Designer n _coU NICET#104519= 14 awg 2cond FPLR + Fire Alarm Systems,Level IV Reliable. Innovative. - + (I) Solutions Oriented. — D + Y 111111AAcme Q o Fire Alarm —u) 0 COMPANY 970.625.5535 W. Clint@acmealarm.com "Providing Life Safety Solutions" www.acmealarm.com WIRING + cn Speaker-Strobe Wiring Typical + a) o M03 DRAWN B Y. CAB CHECKED B Y: SCALE: u — O C Project Name and Address �1 — 0 APPROVED B Y. DISK: DATE:5-11-07 mut lJ Acme Alarm Company Manrico Retail Sonnenalp 30 Meadow Drive #A Vail, CO 81657 3 Project Sheet Manrico Retail Fire Date 12/10/18 FA1 NORTH Scale 1' 970.62 :. ak\i, 800.55 .T PO Box . 0 � thli - Acme Rifle, CO Fire Alarm acmealMetimrgency Services COMPANY "Providing Life Safety Solutions' Approved for install/changes. Field Scope of Work: inspection for hornstrobe locates required. Sonnenalp Manrico USA INC. 30 Meadow Drive#A Vail,CO 81657 Scope: 1. Rough in wire to existing device location due to changes in the elevation, pathways and wall layout. 2. Remove 2 out of 4 smoke detectors and layout to corridor spacing. 3. Create splice box in accessible areas. 4. Remove 1 of 2 pull stations leaving main entry only. 5. Remove 2 out of 4 speaker/ strobes and relocate for complete coverage. 6. Remove unused wire and wire manage all existing. 7. Set boxes into new ceiling grid. 8. Wire through existing locations to remain until sheet 9. Trim 2 smoke detectors after drywall and paint. 10. Trim and adjust 2 Speaker Strobes for correct coverage. 11. Pull Sensitivity and test of all devices. Operations: 1. The smoke detectors and pull stations shall be general alarm sounding voice evac and visual notification. Notes: 1. The above componentsshall be tied into an existingPanel and Circuits. 2. All speakersshall be mounted on ceiling 3. Wiringf orSpeakerstrobecircuitsshall be run in 14/2 awgshieldedandl4/2awgnon-shieldedFPLRf irewire. 4. Wiringf orAddressable SLC circuitsshall be run in 16/4awgFPLRf irewire 5. Allwiringwillbe runa min.of 6 inches romAC powerand cross AC power at rightangles. 6. Smoke Detectors shall be locateda min.of 3'f romany air supply or return. 7. Finish trim of smoke detectors to be completedat the end of the f inalcleanupphase of construction just prior to occupancy. 8. All rough-inwiring shall be labeled at each device and junction. 9. All rough-inwiring shall be mountedto structural framing. 10. Any wiringbelow finished ceilinglevelshall be housed in rigid or f lexEMT conduitwhererequiredby code. Device Box Schedule 1. All devicesshall be mountedto back boxes. 2. Back boxes f oreach mini soundershall be single gang deep. 3. Back boxes f oreach smoke detector and heat detectorshall be plastic 4 inch round,4-inch metal octagonal,or f our inch squarewitha p ring. Baron FerNguuson 01 Reliable. Innorall re. Salute.Oriented. Anne Fire Alarm COMPANY 970.625.5535 ^Providing Life Safety Solutions^ baron@a<mealarm.cum NICET# 124001 Fire Alarm Systems Level III