Loading...
HomeMy WebLinkAboutF18-0079_Approved Documents_1544570816.pdf 75 South Frontage Road Fire-Construction Permit West, TOWN OFVAIL F18-0079 Vail,CO 81657 Issued: 12/11/2018 TOWN of VAIL0.ZOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 355 FORESTRDA(210107113043 A)(210107113043 ) Unit#:A ParcelNumber: 210107113043 Subdivision:VAILVILLAGE FILING 3 Block:2 Lot:1 PARCEL A BK-0615 PG-0674 MAP 08-05-93BK- LegalDescription: 0615 PG-0795PWA 08-06-93BK-0615 PG-0798QCD 08-05-93BK-0629 PG-0415 QCD 12-29-93BK- 0630 PG-0806 QCD 01-25-94 R761843 QCD 07-05-01 R761845 QCD 07-10-01 R841560 QCD 07-21- 03R895164DEC 10-21-04 Contacts ContactType:Applicant Full Name:Peter Mazen Address: 274 CenterDrive Glenwood Springs,CO 81601 Phone: 3037920022 ContactType:PropertyOwner Full Name:STALLION REAL ESTATE LLC Address: Phone: None Contractor Contractor Type:Fire Protection Company: WesternStates Fire ProtectionCo. State License#: Phone: 303-549-8975 Projectlnformation ProjectName:Stallion Real Estate 2015 ProjectDescription: Retrofitofsprinklers in 355 Forest Road remodel. Fees Paid Account#:001-0000.31111.04 Fire Suppression Permit Fee Fee Amount: $990.25 Account#:001-0000.31123.00 Fire Suppression ReviewFee Fee Amount: $432.00 TotalPaid: $1,422.25 Conditions Issued By:Town of Vail Fire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicant agrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0079 Date Printed: 12/05/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0079 Status: Created Permit Number: Date Started: 12/05/2018 Permit Type: Fire-Construction Permit Subcases Fire Suppression Lot Number: 1 Property: 355 FOREST RD A(210107113043 A)(210107113043) Contacts Contact Type: Applicant Company Name: Western States Fire Protection Full Name: Peter Mazen Address: 274 Center Drive Glenwood Springs,CO 81601 Email: peter.mazen@wsfp.us Contact Type: Property Owner Full Name: STALLION REAL ESTATE LLC Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $990.25 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Review Fee 12/05/2018 Check $432.00 Paid By:Western States Fire Protection-Notes:124581-Western States Fire Protection Fire Suppression Permit Fee 12/05/2018 Check $990.25 Paid By:Western States Fire Protection-Notes:124581-Western States Fire Protection FEE TOTAL $1,422.25 AMOUNT PAID $1,422.25 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 12/05/2018-3:03:28 PM-Generated by:do ouc h 1/1 6 Western States Fire Protection Co. P 4iied awd pl.oftez y FIRE PROTECTION SYSTEM Material And Hydraulic Calculation Submittal 355 Forest Road Vail, CO 81657 Thomas M.Coakley,CET Western States Fire Protection Co. NICET Level III Registration#107852 Sprinkler System Layout Signa .- Prepared by: Peter Mazen Project Manager Western States Fire Protection Co. 274 Center Drive Glenwood Springs,CO 81601 Phone(970)-618-3294 Fax(970)945-9504 WSFP#CS3027 May 22,2018 +- Hydraulic Overview Job Number:CS3027 Resort Descri.tion:Gara.e Job Number Design Engineer CS3027 Peter Mazen Job Name: Phone FAX 355 Forest Rd Address 1 State Certification/License Number Vail,CO 81657 Address 2 AHJ Address 3 Job Site/Building System s Density Area of Application 0.100gpm/ft2 1500.00ft2(Actual 157.73ft2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 17.00 at 12.037 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 225.00ft2 4 System Pressure Demand System Flow Demand 83.748 70.44 Total Demand Pressure Result 170.44 @ 83.748 +11.041 (11.6%) Supplies =IF Check Point Gauges Node Name Flow(qpm) Hose Flow(gem) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(qpm) 1 Water Supply 762.00 100.00 100.000 16.800 CS3027-355 Forest Rd Submittal pendent 5.10.18.c Water Supply at Node 1 (762.00,0.00,100.000, 16.800) 150 135 • 120 • :EL r _ 1 105 Static Pressure 100.000 .N 90 70.44 @ 83.748 Q to 1 1 °' 75 170.44 with hose streams w 92 60 \ System demand curve fi...... ---,.-46,;:..._.....11::.17 w LT '''...t. 1 1 30 2 15 762.00 @ 16.800 0 1 minim 111111111 1111 III 1111 i t 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 000 600 750 900 1050 1200 1350 1500 Water flow,gpm L©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.61.0 5/22/2018 10:36:46AM Page 1 Hydraulic Graph Job Number:CS3027 Report Description:Garage Water Supply at Node 1 150 135 120 105 Static Pressure 100.000 90 -\\ 70.44 k 83.748 170.44 with'hose streams N I 75 N _ 60 45 -System demand curve 30 — 762.00 @ 16.800 150 — 111111111 11111 III 111111111 1 1 1 1 1 1 1 1 1 I II I I I I I I I I I I I I I I I 0150 300 450 600 750 900 1050 1200 1350 1500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 Static:Pressure 100.000 Residual Pressure 16.800 @ 762.00 Available Pressure at Time of Test 94.789 @ 170.44 synem Demaed 83.748 @ 70.44 System Demand(Including Hose Allowance at Source) 83.748 @ 170.44 ,ik,©M.E.P.CAD,Inc. M AutoSPRINK®12 v12.0.61.0 5/22/2018 10:36:49AM Page 2 Ei Summary Of Outflowing Devices Job Number:CS3027 c. • - Report Description:Garage Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Sprinkler 203 18.56 13.00 4.9 14.341 Sprinkler 209 17.70 17.00 4.9 13.056 Sprinkler 215 17.18 17.00 4.9 12.295 b Sprink ler 221 17.00 17.00 4.9 12.037 b Most Demanding Sprinkler Data LM,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.0.61.0 5/22/2018 10:36:51AM Page 3 .- iii Hydraulic Analysis Job Number:CS3027 Report Description:Garage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 BL 1.0550 17.00 6.24 150 0.062010 1'-3'% Pf 0.080 221 27'-0 17.00 4.9 12.037 Sprinkler Pe 67 27'-0 12.117 1'-3'% Pv BL 1.2910 17.00 4.17 150 0.023200 7'-8% Pf 0.179 67 27'-0 12.117 Pe 215 27'-0 12.295 7'-8% Pv BL 1.2910 34.18 8.38 150 0.084465 9'-0 Pf 0.760 215 27'-0 17.18 4.9 12.295 Sprinkler Pe 209 27'-0 13.056 9'-0 Pv BL 1.2910 51.89 12.72 150 0.182815 5'-0'% Pf 1.468 209 27'-0 17.70 4.9 13.056 Sprinkler, 3'-0 Pe 8 27'-0 14.523 T(3'-0) 8'-0% Pv BL 1.2910 70.44 17.27 150 0.321853 5'-10'% Pf 2.857 8 27'-0 18.56 14.523 Flow(q)from Route 2 3'-0 Pe 13 27'-0 17.381 T(3'-0) 8'-10'% Pv FR 1.5270 70.44 12.34 150 0.142093 48'-11'% Pf 30.366 13 27'-0 17.381 20'-6 Pe 8.815 2 6'-8 56.562 2Tr(1'-0),sCV,6E(2'-6), 69'-5%Pv BFP(-12.500),PRV(-8.000), T(3'-6) UG 1.4810 70.44 13.12 150 0.164917 180'-0 Pf 29.931 2 6'-8 56.562 1'-6 Pe -2.746 1 13'-0 83.748 EE(1'-6),S 181'-6 Pv 100.00 Hose Allowance At Source 1 170.44 - Route 2 BL 1.0550 18.56 6.81 150 0.072918 0'-6 Pf 0.182 203 27'-0 18.56 4.9 14.341 Sprinkler, 2'-0 Pe 8 27'-0 14.523 T(2'-0) 2'-6 Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) 4.11 C Value Multiplier= ( Actual Inside Diameter 4.$7 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. ,111 AutoSPRINK®12 v12.0.61.0 5/22/2018 10:36:53AM Page 4 Hydraulic Analysis Job Number:CS3027 Report Description:Garage Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend r -Fittings Legend ' AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow Eel 111/4°Elbow Ee2 22W Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.0.61.0 5/22/2018 10:36:53AM Page 5 +� Hydraulic Overview Job Number:CS3027 Ree ort Descri•tion:Great Room Job Number Design Engineer CS3027 Peter Mazen Job Name: Phone FAX 355 Forest Rd Address 1 State Certification/License Number Vail,CO 81657 Address 2 AHJ Address 3 Job Sile/Building System s Density Area of Application 0.100gpm/ft2 1500.00ft2(Actual206.32ft2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 13.00 at 7.039 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 225.00ft2 4 System Pressure Demand System Flow Demand 83.842 54.99 Total Demand Pressure Result 154.99 @ 83.842 +11.787(12.3%) Supplies =IF Check Point Gauges Node Name Flow(qpm) Hose Flow(qpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(qpm) 1 Water Supply 762.00 100.00 100.000 16.800 CS3027-355 Forest Rd Submittal pendent 5.10.18.c Water Supply at Node 1 (762.00,0.00,100.000, 16.800) 150 135 • 120 1. 1_._r–: 1 1 IA 105_Static Pressure 100.000 .N 90-54.99 @ 83.842 Q An >• I I ai 75 154.99 With hose streams 4_. wa� .., 60 I. \• = System demand curve 45 1 q - 1 - -‘:.- 30 11-: 15 \.00@16.800 04111111BULL1111111111111111 111111111 111111111 111111111 111111111 000 600 750 900 1050 1200 1350 1500 Water flow,gpm L©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:22AM Page 1 Hydraulic Graph Job Number:CS3027 - Report Description:Great Room Water Supply at Node 1 150 135 120 105 Static Pressure 100.000 90 -\\ 54.99 re re 83.842 154.99 with hose streams .N n fg 75 fn to m 60 - 45 System demand curve 30 — 762.00 @ 16.800 15 0 -11BL111111III 111111III 111111111 111 1 1 1 1 1 1 1 1 1 1 1 III 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111111 0150 300 450 600 750 900 1050 1200 1350 1500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 Static:Pressure 100.000 Residual:Pressure 16.800 @ 762.00 Available Pressure at Time of Test 95.629 @ 154.99 symam Damane 83.842 @ 54.99 System Demand(Including Hose Allowance at Source) 83.842 @ 154.99 iL� ©M.E.P.CAD,Inc. M AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:24AM Page 2 i Summary Of Outflowing Devices Job Number:CS3027 c. • - Report Description:Great Room Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Sprinkler 201 14.19 13.00 4.9 8.387 4 Sprink ler 202 13.00 13.00 4.9 7.039 Sprinkler 204 14.51 13.00 4.9 8.764 Sprinkler 205 13.29 13.00 4.9 7.360 * Most Demanding Sprinkler Data ©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:26AM Page 3 iii Hydraulic Analysis Job Number:CS3027 Report Description:Great Room Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 BL 1.05 5 0 13.00 4.77 15 0 0.037751 8'-6 Pf 0.321 202 28'-0 13.00 4.9 7.039 Sprinkler Pe 205 28'-0 7.360 8'-6 Pv BL 1.05 5 0 26.29 9.65 15 0 0.138942 5 2'-9 Pf 8.440 205 28'-0 13.29 4.9 7.360 Sprinkler, 8'-0 Pe 8.671 95 8'-0 24.470 3T(2'-0),E(2'-0) 60'-9 Pv BL 1.2910 26.29 6.44 150 0.05 1983 4'-6% Pf 0.341 95 8'-0 24.470 2'-0 Pe 90 8'-0 24.812 E(2'-0) 6-6% Pv BL 1.5 270 26.29 4.61 15 0 0.02295 0 9'-0 Pf 0.287 90 8'-0 24.812 3'-6 Pe -3.902 51 17-0 21.197 C(3'-6) 12'-6 Pv BL 1.2910 26.29 6.44 150 0.051983 2'-0 Pf 0.104 51 17-0 21.197 Pe 63 17'-0 21.301 2'-0 Pv _ BL 1.2910 54.99 13.48 150 0.203553 41'-6% Pf 10.495 63 17'-0 28.70 21.301 Flow(q)from Route 2 10'-0 Pe 1.301 206 14'-0 33.096 2T(3'-0),2E(2'-0) 51'-6%Pv BL 1.5270 54.99 9.63 150 0.089865 26'-8 Pf 4.642 206 14'-0 4.9 33.096 25'-0 Pe -5.636 13 27'-0 32.103 3E(2'-6),5T(3'-6) 51'-8 Pv FR 1.5270 54.99 9.63 150 0.089865 48'-111Y Pf 26.740 13 27'-0 32.103 20'-6 Pe 8.815 2 6-8 67.658 2Tr(1'-0),sCV,6E(2'-6), 69'-51h Pv BFP(-12.5 00),PRV(-8.000), T(3'-6) _ UG 1.4810 54.99 10.24 150 0.104300 180'-0 Pf 18.930 2 6-8 67.658 1'-6 Pe -2.746 1 13'-0 83.842 EE(1'-6),S 181'-6 Pv 100.00 Hose Allowance At Source 1 154.99 - Route 2 BL 1.05 5 0 14.19 5.21 15 0 0.044393 8'-6 Pf 0.377 201 28'-0 14.19 4.9 8.387 Sprinkler Pe 204 28'-0 8.764 8'-6 Pv BL 1.0550 28.70 10.53 150 0.163348 37'-6% Pf 7.768 204 28'-0 14.51 4.9 8.764 Sprinkler, 10'-0 Pe 4.769 63 17'-0 21.301 C(2'-0),2T(2'-0),2E(2'-0) 47'-6% Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) Ili C Value Multiplier II ( Actual Inside Diameter 4'$7 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. ,111 AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:27AM Page 4 Hydraulic Analysis Job Number:CS3027 Report Description:Great Room Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend i AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow Eel 111/4°Elbow Ee2 22W Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:27AM Page 5 +' ; Hydraulic Overview Job Number:CS3027 Resort Descri•tion:Master Bedroom Job Number Design Engineer CS3027 Peter Mazen Job Name: Phone FAX 355 Forest Rd Address 1 State Certification/License Number Vail,CO 81657 Address 2 AHJ Address 3 Job Site/Building System Density Area of Application 0.100gpm/ft2 275.48ft2(Actual 275.48ft2) Most Demanding Sprinkler Data Hose Streams 4.4 K-Factor 14.00 at 10.124 100.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 225.00ft2 4 System Pressure Demand System Flow Demand 83.691 57.83 Total Demand Pressure Result 157.83 @ 83.691 +11.788(12.3%) Supplies Mr Check Point Gauges Node Name Flow(qpm) Hose Flow(qpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(ppm) 1 Water Supply 762.00 100.00 100.000 16.800 CS3027-355 Forest Rd Submittal pendent 5.10.18.c Water Supply at Node 1 (762.00,0.00,100.000, 16.800) 150 135 120 • -1—" --r— r k --------- 105 Static Pressure 100.000 .7) 90 .7.83 @ 83.691 1? * I I °' 75 157.83 with hose streams T2 1n o_ \ = 45 System demand curve 1 ar 30 2 - \.00@16.800 15 0 MITIIIII11111111III 111111111 111111111 111111111 111111111 ,M00450 600 750 900 1050 1200 1350 1500 Water flow,gpm L©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:45AM Page 1 Hydraulic Graph Job Number:CS3027 - Report Description:Master Bedroom Water Supply at Node 1 150 135 120 105 Static Pressure 100.000 90 -\\ 57.83 re re 83.691 IHP .N 157.83 with hose streams J75 60 - 45 -System demand curve 30 — 762.00 @ 16.800 15 0 1 1 1 1 1 III 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111111 0150 300 450 600 750 900 1050 1200 1350 1500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 Static:Pressure 100.000 Residual:Pressure 16.800 @ 762.00 Available Pressure at Time of Test 95.480 @ 157.83 syatam Demand 83.691@ 57.83 System Demand(Including Hose Allowance at source) 83.691 @ 157.83 �4 ©M.E.P.CAD,Inc. M AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:46AM Page 2 i Summary Of Outflowing Devices Job Number:CS3027 .t +• - Report Description:Master Bedroom Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Ets Sprinkler 207 14.00 14.00 4.4 10.124 Sprinkler 208 14.14 14.00 4.4 10.322 Sprinkler 213 14.36 14.20 4.4 10.656 Sprinkler 220 15.33 14.20 4.4 12.147 * Most Demanding Sprinkler Data LM,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:48AM Page 3 b�ii Hydraulic Analysis Job Number:CS3027 Report Description:Master Bedroom Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 BL 1.0550 14.00 5.14 150 0.043298 26'-7A Pf 1.498 207 28'-0 14.00 4.4 10.124 Sprinkler, 8'-0 Pe 4.769 58 17-0 16.391 C(2'-0),T(2'-0),2E(2'-0) 34'-7% Pv BL 1.0550 28.36 10.41 150 0.159857 6'-11'% Pf 1.434 58 17-0 14.36 16.391 Flow(q)from Route 3 2'-0 Pe 63 17'-0 17.825 T(2'-0) 8'-11% Pv BL 1.2910 42.50 10.42 150 0.126376 3'-4'% Pf 0.803 63 17'-0 14.14 17.825 Flow(q)from Route 2 3'-0 Pe 60 17-0 18.628 T(3'-0) 6'-4'% Pv BL 1.2910 57.83 14.17 150 0.223460 38'-2%z Pf 10.102 60 17'-0 15.33 18.628 Flow(q)from Route 4 7'-0 Pe 1.301 206 14'-0 30.030 2E(2'-0),T(3'-0) 45'-2'%Pv BL 1.5270 57.83 10.13 150 0.098654 26'-8 Pf 5.096 206 14'-0 4.9 30.030 25'-0 Pe -5.636 13 27'-0 29.491 3E(2'-6),5T(3'-6) 51'-8 Pv FR 1.5270 57.83 10.13 150 0.098654 48'-11'% Pf 27.350 13 27'-0 29.491 20'-6 Pe 8.815 2 6'-8 65.656 2Tr(1'-0),sCV,6E(2'-6), 69'-5%Pv BFP(-12.500),PRV(-8.000), T(3'-6) UG 1.4810 57.83 10.77 150 0.114500 180'-0 Pf 20.781 2 6'-8 65.656 1'-6 Pe -2.746 1 13'-0 83.691 EE(1'-6),S 181'-6 Pv 100.00 Hose AllowanceAt Source 1 157.83 - Route 2 BL 1.0550 14.14 5.19 150 0.044079 48'-9'% Pf 2.502 208 28'-0 14.14 4.4 10.322 Sprinkler, 8'-0 Pe 8.671 95 8'-0 21.494 3T(2'-0),E(2'-0) 56'-9%Pv BL 1.2910 14.14 3.46 150 0.016491 4'-6% Pf 0.108 95 8'-0 21.494 2'-0 Pe 90 8'-0 21.603 E(2'-0) 6'-6% Pv BL 1.5270 14.14 2.48 150 0.007281 9'-0 Pf 0.091 90 8'-0 21.603 3'-6 Pe -3.902 51 17'-0 17.792 C(3'-6) 12'-6 Pv BL 1.2910 14.14 3.46 150 0.016491 2'-0 Pf 0.033 51 17'-0 17.792 Pe 63 17-0 17.825 2'-0 Pv - Route 3 BL 1.0550 14.36 5.27 150 0.045400 13'-3'% Pf 0.966 213 28'-0 14.36 4.4 10.656 Sprinkler, 8'-0 Pe 4.769 58 17'-0 16.391 C(2'-0),2T(2'-0),E(2'-0) 21'-3'% Pv Route 4 BL 1.0550 15.33 5.63 150 0.051243 25'-5 Pf 1.712 220 28'-0 15.33 4.4 12.147 Sprinkler, 8'-0 Pe 4.769 60 17'-0 18.628 C(2'-0),T(2'-0),2E(2'-0) 33'-5 Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) a C Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. ilii AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:50AM Page 4 Hydraulic Analysis Job Number:CS3027 Report Description:Master Bedroom Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend ' AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow Eel 111/4°Elbow Ee2 221/4°Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. ,111 AutoSPRINK®12 v12.0.61.0 5/22/2018 10:37:50AM Page 5 Specially FLEXI-FIN® SYSTEM TIA Products Specification Sheet 0 PART NO. DESCRIPTION MSTR CTN QTY/LBS �� PIPE CLAMP P-2031 FF PC 1/2" 1000/13 o. `�. P-2032 FF PC 3/4" 1000/14 P-2033 _FF PC 1" 250/08 P-2025 FF PC 1-1/4" 800/29 P-2027 FF PC 1-1/2" 600/26 P 2029 FF PC 2" 300/21 4%. , INSULATING SUSPENSION _ P-2062 FF ICS 1/2" 1000/17 P-2063 FF ICS 3/4" 1000/15 P-2064 FF ICS 1" 250/08 P-2056 FF ICS 1-1/4" 800/27 P-2058 FF ICS 1-1/2" 600/25 SPECIFICATION P-2060 FF ICS 2" 300/16 Furnish and install Flexi-Fin® Pipe Clamp, PIPE INSULATOR FOR WOOD AND METAL STUDS Insulating Suspension and Pipe Insulator P-2086 FF PI 1/2" 1000/17 for Wood and Metal Studs as manufactured P-2087 _FF PI 3/4" 1000/16 by LSP Products Group/Specialty Products. P-2089 _FF PI 1" 300/06 DESIGN FEATURES ❑ Secures copper,CPVC and PEX piping to both wood and metal framework. ❑ Use in both residential and commercial construction. ❑ Beige in color. ❑ Insulating Suspension high-ear design allows installation in hard-to-reach areas. ❑ Pipe Insulator for Wood and Metal Studs exteriorfins securely fasten insulator to both wood and metal studs. Ideal for potable and hydronic water systems. COMPLIANCES/LISTINGS IAPMO File#2139 Produ ctSu bmittal Job Name Date Part Number Quantity PR0DUCTi3 Fa LI 2727 Chemsearch Blvd.,Irving,TX 76051 Phone(800)854-3215 Fax(800)243-1777 E-mail:sales@Ispproducts.com Website:www.lspproducts.com Architect Content matteris subject to change at any time.It is the user's responsibility to ensure the most updated revisions are obtained. Contractor SP/S-2027 (03-02)Rev 1 0) 1.0LCO, ,nr,n„n,.tolco.com a brand of NIBCO" Revision 12/18/2008 Fig. 200 - "Trimline"Adjustable Band Hanger C0 LIS LISTED Fig. 200R (Import)- "Trimline" Adjustable Band Hanger 4> w/Retainer Ring Size Range — 1/2" thru 8" pipe Material — CarbonSteel, Mil. Galvanized to G90 >• specifications �� �� `� Function— For fire sprinkler and other general piping ``�`" 4/ purposes. Knurled swivel nut design permits hanger � 3 " -\„ adjustment after installation. , (a/ ,, ,, Features— _ • (1/2" thru 2") Flared edges ease installation for B 1 B all pipetypesand protect CPVC plastic pipe „, r„ ,-, „ from abrasion. Captured design keeps adjusting A , nut from separating with hanger. Hanger is eas- ily installed around pipe. A • i _--- 2/2 thru 8 S ring tension on nut holds it � ___ ( ) P g securely in hanger before installation. Adjusting nut is easily removed. Fig.200 1" -2" Fig.200 21/2-8" Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA(UL)and Canada(cUL) 411!!e . for steel and CPVC plastic pipeand Factory Mutual 'V u\ Engineering Approved (3/4"thru 8"). Conformsto «;;::.::. . FederalSpecifications WW-H-171E, Type 10 and ® `� Manufacturers Standardization Society SP-69, Type 7-, 10. B Maximum Temperature — 650°F I B Finish — Mil. Galvanized.Stainless Steel materials will ��,�I be supplied with (2) hex nuts in place of a knurl nub. Pp II, Order By — Figure number and pipesize Note— Figure 200R (import) with retainer ring and A A non-captured knurl nut. Fig.200R 21/2"-8" Fig.200R 1/2"-2" Dimensions'Weights Pipe Rod Size Max.Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/s 21/2 400 11 1 3/8 8mm or 10mm 33/s 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/s 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/2 600 27 3 3/8 10mm 57/s 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/2 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX:951.737.0330 CUSTOMER SERVICE•800.786.5266 91 www.toico.com FDLCO® www.tolco.com a brand of NIBCO' Revision 12/15/2008 Fig. 98 - Rod Stiffener liorniaOS PDof teof CaliforniaOSHPDApproved Seismic Restraints System p Fig. 98B - Rod Stiffener w/Break-off Bolt Head :'J, C-: Size Range — Secures 3/8" thru 7/8" hanger rod --' Material — CarbonSteel =i Function — Secures channel to hanger rodforvertical seismic bracing. (p. s-Approvals — Included in our Seismic Restraints Catalog approvedby the State of California Office of Statewide Health Planning and I ' Development (OSHPD). For additional load, spacing and placement information relating to OSHPD p rojects,p lease ref erto the TO LCO Seismic Restraint Systems Guidelines FIG. 98 ' Finish — Electro Galvanized Note — Available in HDG f inish or Stainless Steel materials. Order By — Figure number 4*,I ,I ,R.:"--- r viii. \ 0 I i -, 1-11...Q FIG.98B '`=i- ' Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in ��� Dimensions 1" increments �� Rod Max. Rec.Load Lbs. Material — CarbonSteel ``l(( ��� Size For Service Temp Maximum Temperature — 750°F � 650°F Finish — Plain `l( � 3/8 730 1/2 Note — Available in Electro-Galvanized and l( (ill/�� 5/88 211 2160 HDG f inish or Stainless Steel materials. /� 3/4 3230 Order By — Figure number, rod diameter, rod t( 7/8 4480 length and f inish Fig. 100 - All Thread Rod Full Length Size Range — Secures 3/8" thru 11/2 rod in � 1������ S 10' lnghs � )) ) Material CarbonSteel Maximum Temperature — 750°F � V � � Finish — Plain Note — Available in Electro-Galvanized and Dimensions •Weights HDG f inish or Stainless Steel materials. Max Rec.Load Lbs. Order By — Figure number, rod diameter Rod For Service Temps Approx. and f inish Size 650°F Wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 ® OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX:951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com VERTICALMOUNT SAMMYS® SAMMYS° f orWood Installs VERTICALLY into the bottom of woodstructures easilyand quickly! 1 alli. alli. AM Not less than Wood Flooring .. 2"nominal width Product Features (1-1/2")► •No pre-drilling required. • Not less than •Quick to install using the Sammy 13"nominal Nut Driver with an 18V cordless thickness(2-1/2°) (depth or side Wood Joist drill/driver. of vertical member) • _ = y' tiry 'rye , GMEEF �L' •Saves time from traditional Double Sheetrock methods. For vertical use- Ceiling install in center of lower face. •Reduces installation cost. Minimum 2"embedment into base material for NFPA13 compliance. Composite/Truss •Made in the U.S.A. Consult truss manufacturerfor recommended installation point. "Pre-drilling maybe required forGST V 25-380.Tool available on page 10. Ill Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(lbs L oad(Ibs) L oad(Ibs) Qty Qty 1/4" 8002957 GST 100 1/4 x 1" 210 (7116"OSB) 25 125 670 (3/4"Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 ` " 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16"OSB) 300 25 125 670 (3/4"Ply) — ®•0 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 V` 3/8" 8068925 GST 20-SS 1/4 x 2" 1760 (Fir) 850 25 125 °`• 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 4-0 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 part#8113910 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 _ 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275(Fir) 25 125 — 1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 #14 SW Red — Nut Driver Part#8114910 SAMMY Swivel Head° f orWood Installs VERTICALLY and swivels up to 17° in woodstructur Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/:"x 12 pitch roof. •Reduces installation cost.11111 — •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout(lbs) Load(Ibs) Load(Ibs) Thickness Qty Qty (14<> 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25125 125 :.,(')..<> 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-offfeaturewhich providesa fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. y lb, the most up to date information,visit www.sammysuperscrew.com 4 L ; SAMMYS® HORIZONTALMOUNT SIDEWINDERS° f orW oodnstalls HORIZONTALLY into the side of woodstructures easilyand quickly! • Not less than 2"nominal width Product Features O (1-1/2")up to 3-1/2"pipe;not less than •No pre-drilling required. 3"(2-1/2")nominal width 4"&5"pipep 9 Floor Joist •Quick to install using the Sammy } Minimum 2-1/2"from bottom for # branch lines.Minimum 3°from Nut Driver with an 18V cordless bottomformain lines.Exception:This drill/driver. requirement shall not apply to 2"or thicker nailing strips resting on top of steel beams. •Saves time from traditional methods. • •Reduces installation cost. CI •Made in the U.S.A. 0 ----414111_11--;:f, 0 : -------- —!'i Composite/Truss21111 C onsulttruss manufacturerfor recommended installation point. "Pre-drilling may be required for Model • SWG 25-380(tools available on pg 10) Approvals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Pullout(lbs) Load(Ibs) Qty Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 _i 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 125 I CL 125 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 ®, 3/8" 8021957 SWG 20 114 x 2" 1725 (Fir) 1050 25 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 #14 SW Red ®• 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver I 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Part#8114910— VERTICAL HORIZONTAL 1.Insertthe appropriate nut driver into a 3/8'or 1/2"portable drill. 1.Insertthe appropriate nut driver into a 3/8'br 1/2"portable drill. 2.Insertthe SAMMY Snto the#14(black)nut driver(p/n 8113910).Drill 2.Insertthe SAMMY Snto the#14SW(red)nut driver(p/n 8114910).With drill shouldbe in a vertical position. unitin a horizontal position and at a rightangle to the structural member, begin installation. 3.Push the face of the nut driver tightto the member.When the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMY Ss now readyto receive 1/4",3/8", 1/2"or metric all threadrod,bolt stock(The 1/2"requires the#14SWred nut driver) 4.The unitis now readyto receive 1/4",3/8 ormetrical/threadrodor boltstock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 footlbs.formaximum Note:When installing SWDR,follow the above instructions,then add retainer nut pulloutin puffin steel. and torque to 20 footlbs.formaximum pulloutinpurlin steel. iEl e ril':V) er MEM MEP. __ ,1 ., _ iti . eort., . ......,. i., i Kpii. , 1"..... 7..,.._ ....„..,..x.x I.. Au SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-offfeaturewhich provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 5 Tofi nd a distributornear you,call 800-BUILDEX SAMMYS® DESCRIPTION/SUGGESTED SPECIFICATIONS Selfdrilling &sel ftapping into steelup to Anchors 1/2"thick— The Steel Sammy is made using Teks®self-drilling fasteners,perfectforHanging Sprinklers,Pipes,Electrical forSteel Fixtureor HVAC Equipment to steel purlin,structuralbeams,and open web joist. The Steel Sammy is available in verticalmount,horizontal mount, and Swivel mount to accommodate all fastening situations. Installs into steel ADVANTAGES structures easily MadewithTeks®self-drillingfasteners— Reduces installation cost. no pre drilling required. Quick to install using the Sammy Nut Driver and quickly! Install into steel range from 22 gauge— with a no load speed 2000-2500rpm, 1/2"thickness minimum 6 amps drill/driver. Available _ Saves timefromtraditionalmethods. in Vertical, Sammy's Vertical MountProduct Features Horizontal and Swivel Head aiwA N® RI``ING BI-REQIIIRE® � VERTICALMOUNT • MADE MR Sammy's Sidewinder® Product N® ILLING Features ARE-®�QUIRE® MADE WITH SIDEWINDERS® FOR STEEL HORIZONTAL MOUNT ITH7 S® Construction Products SAMMY Call our or visitwww.itwconstruRion.ca forgeneralinformation. Visit ITW B uildex'sSAMMVSweb site www.sammysuperscrew.com forthe most currentproductand technical information. SAMMYS f orSteel APPLICATIONS APPROVALS 9 SprinklerSystems See Selection Chartfor items with approvals. '�' - Pipes/Plumbing y_ ElectricalLighting and Fixtures t` _ HVAC Equipment and Fixutres INSTALLATION INSTRUCTIONS VERTICAL MOUNT \ M-c. . Wil el:r '-' vci I _ :'' : , Fig.1 Fit 2. Fig. - Fit.4 ` 1. Insert theappropriatenutdriverintoa 3/8"or1/2"portabledrill. pm2. Insert the SAM MYSntothe#14(black)nut driver(p/n8113910). Drill should be in a verticalposition. Push the faceofthe nut drivertighttothe member.When the nut 1 \ driver spins freelyon the SAM M YSstop drill and remove. „` The SAM M YSs now ready to receive1/4",3/8",1/2"or metricall a " thread rod,bolt stock.(The 1/2'requiresthe#14SW red nut driver) xA _ _ Important Vertical lnstallationNotes 1 Warrantyrequiresthe use of appropriatenut driversf or installation. Model#14 Nut Driver Item No:100 Color:Black y: ,ti 1 I I '� , I Use With Sammysfor1/4"and 3/8"Rod PN 81139 10 �'' tEye protectionshould be wornat all times when installing this product. t ft I INSTALLATION INSTRUCTIONS HORIZONTAL MOUNT i glar OM )111f; i - ilf f N Fig.1 Fig 2. Fig.3 ig.4 Samm ySwivel Head 1. Insertthe appropriatenut driver into a 3/8"or 1/2"portable drill. Product Features 2. Insert the SAMMYS into the#14W(red)nut driver(p/n 8114910). With drill unit in a horizontal position and at a right angle to the Eliminates distortion of threaded rod in structuralmember,begin installation. sloped roof applications. 3. When the nut driverspinsfreeon the SAM MYS$topdrill and remove. Accommodates up to 3 1/2"x 12 pitch. 4.The unit is now readyto receive 1/4",3/8",or metricall thread rod, Installs into angled Z-Purlin;Allows bolt stock. threaded rod to hang plumb. 1 Important Hori zontallnstallation Notes Allows 17°deflectionfrom vertical. Warr antyrequiresthe use of appropriatenut driversforinstallation.Sidewinders must be t, installed using Model#14SW(Red)nut driveronly.Item No:101 PN:8114910 Eye protectionshould be wornat all times when installing this product. IT[/ Construction Products I Call our tollfreenumber 800-387-9692 or visitwww.itwconstruction.ca forgeneral information. ������• C Visit ITW B uildex'sSAMM VSweb sitewwwsammysuperscrew.com forthe most currentproductand technicalinformation. �7 SAMMYS f orSteel SELECTION CHART ■ i i i SAMMYS Vertical Mount • Part#8113910 ■Part#8114910 • Part#8273910 ROD PART ULTIMATETEST TEST MIN MAX BOX CASE NUT SIZE NUMBER MODEL DESCRIPTION PULLOUT �us LOAD ® LOAD THICKNESS THICKNESS QTY QTY DRIVER j (LBS) LISTED (LBS) APPROVED (LBS) 1/4" 8024957 DST R100* 1/4-20x1" 1510 (20ga.) .036"-20ga 3/16" 25 125 TEKS3 1/4" 8025957 DST 100 1/4-14x1" 446(20ga.) .036"-20ga 3/16" 25 125 TEKS3 12-24 x 1-1/2" 1/4" 8030957 TEK500 TEKS5 3125 (3/16") .187"-3/16" 1/2" 25 125 Q`4Y 1/4-20x 1" 3/8" 8038957 DSTR1* TEKS3 1510 (20ga.) 1500 1475 .036"-20ga 3/16" 25 125 3/8" 8039957 DST R516* 5/16-18x1-1/4" 2200(20ga.) 1500 1475 .036"-20ga 1/8" 25 125 TEKS3 1/4-14x1" 446(20ga.) A. 3/8" 8040957 DST10 .036"-20 ga 3/16" 25 125 TEKS3 970(16 ga.) Part# 3/8" 8077925 DST10-SS 1/4-14x1" 446(20ga.) .036"-20ga 3/16" 25 125 8113910 TEKS3 970(16ga.) 1/4-14x1-1/2" 446(20ga.) 3/8" 8041957 DST15 TEKS3 970(16ga.) .036"-20 ga 3/16" 25 125 1/4-14x2 446(20ga.) 3/8" 8042957 DST20 TEKS"3 970(16 ga.) .036"-20 ga 3/16" 25 125 1/4-14x3" 446(20ga.) 3/8" 8044957 DST30 TEKS3 970(16 ga.) .036"-20ga 3/16" 25 125 Mi'I- 3/8" 8045957 DST516 5/16-18x1-1/4" 1500(3/16") 1500 1475 .125"-1/8" 1/8" 25 125 I II TEKS3 3/8" 8046957 TEK50 12-24x1-1/2" 3125 (3/16") 1500 1475 TEKS5-18 x 187"3/16" 1/2" 25 125 1/2" 8034925 DSTR5.16* 5/161/4 TEKS3 2220(20ga.) .036"-20ga 1/8" 25 125 Part# 1/2" 8036925 TEK5.0 12-24x1-1/2" 3125 (3/16") .187"-3/16" 1/2" 25 125 8114910 TEKS5 *Includes retaining out SAMMYS Swivel Head° ROD PART ULTIMATE TEST ® TEST MIN MAX BOX CASE NUT SIZE NUMBER MODEL DESCRIPTION PULLOUT s LOAD LOAD THICKNESS THICKNESS QTY QTY DRIVER LISTED u , (LBS) (LBS) "PR°°E° (LBS) 3/8" 8137957 SH-DSTR1* 1/4-20 x 1" 3220(3/16") 1500 1475 0.35" 3/16" 25 125 Part# TEKS3 8113910 2368(1/2"steelVertical) 1500(Vertical) _/ ) 3/8" 8268957 SH-TEK50 1224x13/4" 1306(45°off Vertical) 850(45°off 4„ 3/16” 1/2" 25 125 TEKS5 2281(3/16"HSS) Vertical) 2-1/2" 1585(3/16"HSS 45°offVertical) Part# 2368(1/2"steelVertical) 8273910 1/2" 8270957 SH-TEK5.0 12-24x1-3/4" 1306(45°offVertical) 3/16" 1/2" 25 125 TEKS5 2281(3/16" 1585(3/16"HSS 45°offVertical) *Includes retaining nut TW Construction Products 5 8 SA MM YS Call ourtollfreenumber800-387-9692 or visitwww.itwconstructian.ca f orgeneral information. Visit ITW Buildex'sSAMMYSwebsitewww.sammysupersaew.com forthe most currentproductand technical information. SAMMYS f orSteel ii i SELECTION CHART SAMMYSHorizontal Mount • Part#8113910 •Part#8114910 ■ Part#8273910 ROD PART ULTIMATE ® TEST Fnno TEST MIN MAX BOX CASE NUT MODEL DESCRIPTION PULLOUT $ LOAD LOAD SIZE NUMBER THICKNESS THICKNESS QTY QTY DRIVER STED (LBS) (LBS) (LBS) 3/8" 8050957 SWD10 1/4-14 x 1" TEKS3 1477(16 ga.) .060"-16 ga 3/16" 25 125 3/8" 8080925 SWD10-SS 1/4-14x1" 1477(16ga.) .060"-16ga 3/16" 25 125 TEKS3 S 3/8" 8051957 SWD15 1/4-14 x 1 1/2" 1477(16ga.) .060"-16ga 3/16" 25 125 I TEKS3 3/8" 8055957 SWDR1* 1/4-20x1" 1900(20ga.) 1500 1475 .036"-20ga 3/16" 25 125 Part# TEKS3 8114910 3/8" 8054957 SWDR1-1/2* 12-24x1-1/2" 2375(3/16") 1500 1475 .188"-3/16" 1/2" 25 125 TEKSS 3/8" 8056957 SWDR516* 5/16-18 x 1-1/4" 2480(20ga.) 1500 1475 .036"-20ga 1/8" 25 125 TEKS3 3/8" 8057957 SWT 15 12-24 x 1-1/2" 2375(3/16") .187"-3/16" 1/2" 25 125 TEKSS SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. PERFORMANCE TABLES SheetSteelGauges GAUGE NO. 26 24 22 20 18 16 14 12 3/16" 1/4" Nominal Decimal Equivalent .018 .024 .030 .036 .048 .060 .075 .105 .188 .250 Ultimate P ull outl/alues (avg.l bs.ultimate)-SAMMYS FASTENER STEELGAUGE(Ibs.) MODEL DIA. PT 20 18 16 14 12 3/16 1/4 DST 1/4 #3 446 613 970 1145 1544 3190 DST516 5/16 #3 457 568 1209 1712 2422 TEK50 #12 #5 487 699 913 1527 3270 3593 DSTR1-1/2" #12 #5 3270 3593 DSTR1" 1/4 #3 1510 DSTR516 5/16 #3 2200 Al uminumCurtainil/al Extrusion Ultimate P ull oubalues (AVERAGELBS.ULTIMATE) FASTENER THICKNESS MODEL DIA. PT. .114 .092 .365 .132 DST10 1/4 #3 1265 2750 SWD 10 1/4 #3 1120 1420 Ultimate Pullout Values (avg.I bs.ultimate)-SIDEWINDERS FASTENER STEELGAUGE(Ibs.) MODEL DIA. PT 20 18 16 14 12 3/16 1/4 SWD 1/4 #3 1477 SWDR1-1/2" #12 #5 2375 SWDR1" 1/4 #3 1900 1900 T��/S7WDR516 5/16 #3 2480 2480 I/ VV Construction Products Call our tollfreenumber 800-387-9692 orvisitwww.itwconstruction.ca forgeneralinformation. SAMMYS.. C n Visit lTWBuildexisAMMYswebsitewww.sammysuperscrew.comforthemost currentproductandtechnicalinformation. .7 7 Swivel HeadT ekdor Seismic Restraint DESCRIPTION �mpropeFEATURES BENEFITS installatI': Structuralattachmentand ■ Reduced installation cost. restraintcomponentcombined; ■ Reduced materialcoordination. it readyforselectedrod. ■ Lesson site material(GO GREEN). ■ No pre-drilling.4 �' ■ Accesstothebackoffastener ■ Aestheticallypleasing. ■ ■ not required. TES TEDStructural Steel � 1Hollow Structural Steel �p ■ Does not requireuse of a _ �1®�� TO •� retaining nut. �E� R(E�f OAR 4 EMENTs OI OI Quick and easy installation. 91► ) :� FOR 3/8"AND 1/2" RODS SPECIFICATIONS scn\- ``'tESTEn to sags DESs% \crmsoR1Es SH-TEK50 FOR3/8"ROD FOR 3/8"RODAND 1/2"ROD C.O.E. & E Structuralattachmentforinstallation of branch/end of line restraintusing 3/8"all Restrained Pi peSize: Up to Schedule 40 pipe 2"or less thread(.299"0D)or end thread rod(.374"OD). Max Length of Designed for use in bar joist,I-beam,rectangular,square,and circularhollow RestraintMaterial: See Maximum Horizontal Load Tables below. structuralsteel ranging from 1/8"to1/2"in low slope or pitched roof designs MaximumAngle: 45°from horizontal (12/12). It maybe used to attachshort length of rod to eliminate lateralsway bracing per NEPA 13,9.3.5.3.8,(2007). Material: Carbon Steel Providesupperstructuralattachmentin a wide range ofsteelthicknesses,from ScrewDescription: 12-24 x 1-3/8"Teks®5 milled point 1/8"through 1/2".This fastening system providesa secureand economical Finish: Electro-zinc(cap),Climaseal®(fastener) attachmentto the structure. Testing: Tested to GR-63-C0REStandardfor performancein SH-TEK 5.0 FOR 1/2"ROD structuralsteel in seismic restraintapplicationsas outlined foruse in NFPA 13 (2007), Structuralattachmentforinstallation of branch/end of line restraintusing 1/2"all 9.3 at an independent test lab.The calculated forceused forthe testing was equal to thread(.405"OD)or end thread rod(.500"OD). thatfound in a Zone 4 and an 8.4 Richterscale seismic event. Designed for use in bar joist,I-beam,rectangular,square,and circularhollow Li sti ngfor3/8"Rod: UL 203 listed as pipe hanger File EX 5098 structuralsteel ranging from 1/8"to 1/2"in low slope or pitched roof designs -Perpendicularto structuralmember—4"Schedule 40 pipe eus (12/12).It may be used to attachshort length of rod to eliminate lateralsway -45°offvertical—2-1/2"Schedule 40 pipe s'E bracing per NFPA 13,9.3.5.3.8,(2007). UL 203A File EX 15565 uL us Providesupperstructuralattachment in a wide range of steelthicknesses,from Listingforl/2"Rod: UL 203A File EX 15565 Gus 1/8"through 1/2".This fastening system providesa secureand economical LISTED attachmentto the structure SELECTION CHART SAMMYS Swivel HeadTeks" -Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8268957 SH-TEK 50 1/8" 1/2" Structural Steel* 25 125 M ustbe installed with#14 SH Nut 1/2" 8270957 SH-TEK 5.0 1/8" 1/2" Structural Steel* 25 125 Driver(ORANGE)(Part No.8273910) *I-Beam, Bar Joist,Hollow Structural Steel PERFORMANCE TABLES Maximum RodLengthforl/r=100,200,300,and400 Least Radi us of Maxi mum Rod Length for I/r(ft) Restraint Shape and Size Nomi nal Diameter Area(i n.2) Gyrati an,r(i n.) I/r=100 I/r=200 I/r=300 I/r=400* Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 Rods(threaded at ends only) 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:NFPA 13, (2007) *Reference:NFPA 13, (2010) TH7 Construction Products S 10 SAMMYS® Call our tollfreenumber 800-387-9692 or visitwww.itwconstrution.ca forgeneral information. Visit ITW B uildex'sSAMMVSweb site www.sammysuperscrew.com f orthe most currentproductand technical information. SAMMYS f orSteel-Seismic Restraint DESCRIPTION(SIDEWINDER) rEsTEDTo; SWDR1-1/2 AND SWDR516 FOR 3/8ROD HTEq i Structuralattachmentfor installation of branch/end of line restraintusing REIRE)y TS 3/8"threaded rod.Used primarily in purlin,bar joist,or other steel structural :� �: 491k members.Thesefasteningsystemsprovideasecureandeconomicalattachment SCiN“TE81<ED '[0 to the structure. WSW DESIES gptESORIE8 C.D.E. 6 f The SWDR1-1/2 model providesupperstructuralattachmentin a range of steel thicknesses,from3/16"through 1/2".A retainingnut is included with eachfastener. The SWDR516 model providesupperstructuralattachmentin a range of steel thicknesses,from20 ga.throughl/8".A retainingnut is includedwitheachfastener. 14 SPECIFICATIONS 4 Restrained Pi peSize: Up to Schedule 40 pipe 2"or less ���, Max Length of RestraintMaterial: See Maximum Horizontal Load Tables below. � /, Maximum Angle: 45°fromhorizontal ,,i. Material: CarbonSteelOVA, ScrewDescription: (SWDR 1-1/2):12-24 X 1-1/2"Teks®5 45o�i — r��,, (SWDR 516):5/16"-18 X 1-1/4"Teks°3 `" L� proper Fi ni sh(both): Electro-Zinc(cap)Silver Climaseal®(screw) installation! k Testing: BX Report#R-1362 • Listing: UL 203 as a pipe hanger c®us UL 203A pending LISTED SELECTION CHART SAMMYS Sidewinders f orSteel-Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8054957 SWDR1-1/2 16 ga. 1/2" Steel PurlinorBarJoist 25 125 The SWDRI 1/2 and SWDR516 must be installed with#14 SW Red Nut Driver(PartNo.8114910). 3/8" 8056957 SWDR516 16 ga. 1/8" Steel PurlinorBarJoist 25 125 No pre-drilling required. PERFORMANCE TABLES Maximum Horizontal Loadsfor Restraint witli/r=100, 200, 300,and400 Least Radius of Maximum Rod Length for Ur(ft) Restraint Shape and Size Nomi nal Diameter Area(in.') Gyrati on,r(i n.) I/r=100 I/r=200 I/r=300 Ur=400* Rods (all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 Rods (threaded at ends only) 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 1/2 in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:NFPA 13, (2007) *Reference:NFPA 13, (2010) IT Construction Products Call our tollfreenumber 800-387-9692 or visitwww.itwconstruction.ca forgeneral information. SAMMYS' s ii Visit ITW B uildex'sSAMM VSweb sitewwwsammysuperscrew.com forthe most currentproductand technicalinformation. NIBCO` www.nibco.com AHEAD OF THE F L O W- Revision 5/1 4/02 Copper Water Tube continued DIMENSIONAL DATA-COPPER WATER TUBE-TYPE"M" TYPE"M" Hard Drawn Only:20-ft.(6.1m)Straight Lengths Usage:For general purpose plumbing,heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting I Safe Working Nominal Diameter Thickness Per Foot Pressure" Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 11/2 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note:Information and data contained in these charts,as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints. "Based on actual laboratory test data provided by Copper Development Association,Inc. e Based upon 150°F(65.6°C)with an allowable stress of 9500 psi(668 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. ® NIBCO INC.WORLDHEADQUARTERS•1516 MIDDLEBURYST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECHSERVICES PH:1.888.446.4226- FAX:1.800.234.0557•INTERNATIONALSERVICE PH:+1.574.295.3221•FAX:+1.574.295.3455 www.nibco.com Bulletin 006 Rev.K February 2017 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate,Concealed Pendent Sprinkler cULus Listed Product Features • cULus Listed as Residential Sprinklers .`— • Push-On cover plate installation _ • Low water flow requirements Product Description Model RFC30 Model RFC43 Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- - � -t• cordance with UL 1626. _ _ = .' Model RFC30 RFC43,and RFC49 sprinklers have a 165°F p (74°C) temperature rated fusible-link operating element. Model RFC49 Model RFC58 Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C)temperature rating are ordinary temperature classification and should be used with a 135°F (57°C)temperature rated cover plate. Sprinklers with a 212°F (100°C)temperature rating are inter /11111.11 - mediate temperature classification and should be used with a 165°F (74°C)temperature rated cover plate. } Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30,RFC43,and RFC49 sprinklersallow 1/2" (13 mm)of cover plate adjustment. Model RFC58 sprinklers allow 3/4"(19 mm)of cover plate adjustment. Model RFC cover plates are available in a variety of finishes Solid Perforated as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or Model RFC Cover Plate perforated cover plates. Table A Nominal K-Factor Max.Coverage Area Sprinkler Sprinkler Model gpm/psii2(I/min/bat-1'2) ft x ft(m x m) Identification Number(SIN) RFC30 3.0(43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20(6.1 x 6.1) RA0612 RFC49 4.9(70.6) 20 x 20(6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20(6.1 x 6.1) RA0613 www.reliablesprinkler.com Model RFC30 Residential Sprinkler SIN RA0611 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPTor ISO 7-1 R1/2 Nominal K-Factor:3.0(43.2 metric) Sensitivity , _ Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165°F (74°C)sprinkler ' �J Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assem bly:Nickel Alloy with PTFE 7'` - Load Screw:Bronze Alloy Sprinkler Wrench - Towers:Copper Alloy Model FC Pins:Stainless Steel `s Deflector:Bronze Alloy Listings and Approvals a r ;" ;. Cup:Steel cULus Listed Bottom View 1 Model RFC30SprinklerComponentsand Dimensions Figure 1 2-5/16"(58 mm) Threads Dia. Body Cup __ _ f _ �_ Tower ~'� H- 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link ... Nominal face of fitting to ceiling °� •�• �` ��a,' '..a..' Deflector(retracted) i'v-r v—v 3/16" 5 mm ) Pin(extended) - Deflector(extended) II1 Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC30 Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Um in) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 2 of 7 February 2017 www.reliablesprinkler.com Model RFC43 Residential Sprinkler SIN RA0612 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) , '111111k Threads:1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:4.3(62 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) "' -1 " f Temperature Rating Material Specifications 165°F (74°C)sprinkler Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assem bly:Nickel Alloy with PTFE r Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC _ Pins:Stainless Steel ��• vsi-- . Deflector:Bronze Alloy Listings and Approvals Bottom View • F-'bt i5 ' Cup:Steel cULus Listed Model RFC43 Sprinkler Com ponents and Dim ensions Figure 2 2-5/16"(58 mm) Threads Dia. Body Cup — = S t .W_4.1 Tower 1-3/4"(44 mm)+1-1/4"(6 mm) � Fusible Link Nominal face of fitting to ceiling �� ��� Deflector(retracted) `ate' '`ate' 3/16"(5 mm) ----- 77/77/, Pin(extended) I I I I Ji Deflector(extended) ; .rtr„-, Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Um in) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 3 of 7 February 2017 www.reliablesprinkler.com Model RFC49 Residential Sprinkler SIN RA0616 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) — Threads:1/2"NPT or ISO 7-1 R1/2 — Nom inal K-Factor:4.9(70.6 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) .;._L <'T Temperature Rating Material Specifications 165°F (74°C)sprinkler — .s Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate r. Sealing Assem bly:Nickel Alloy with PTFE _ Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel -,c . Deflector:Bronze Alloy Listings and Approvals Bottom View ! a Cup:Steel cULus Listed Model RFC49 Sprinkler Corn ponentsand Dim ensions Figure 3 -2-5/16"(58mm) y Threads Dia. Body Cup �' � = f � _ _11 Tower r 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link 1 11.1 Nominal face of fitting to ceilingmill �� l�� ,� 111�� ,� Deflector(retracted) r r=�+ - \\\\\\\ el": 1/////// r 3/16"(5 mm) Pin(extended) MI ► Deflector(extended) _ Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC49 Sprinkler Hydraulic Design Criteria Table D Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Um in) (bar) 16 x 16 13 7.0 (4.9 x 4.9) (49.0) (0.48) 18 x 18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20 x 20 20 16.7 (6.1 x 6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table D above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 4 of 7 February 2017 www.reliablesprinkler.com Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Threads:1/2"NPT or ISO 7-1 R1/2 :" Nominal K-Factor:5.8(84 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) Ordinary: -*- Min. Min.Spacing:8 ft.(2.4 m) 165°F (74°C)sprinkler , '',l'o it 135°F (57°C)cover plate Material Specifications Intermediate: i I, a i/� Therm alSensor:Nickel Alloy Solder Link 212°F (100°C)sprinkler Sprinkler Body:Brass Alloy 165°F (74°C)cover plate • L Levers:Bronze Alloy ., Yoke:Brass Alloy Cover Plate `r: Sealing Assem bly:Nickel Alloy with PTFE Model RFC Cover P late Load Screw:Bronze Alloy -- Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC Deflector:Chrome Plated Bronze Alloy / �'� Cup:Steel Listings and Approvals Bottom View; . ,e cULus Listed , r Cover Plate Finishes (See Table H) Model RFC58 Sprinkler Corn ponentsand Dim ensions Figure 4 2-5/16"(58 mm) Dia. Threads Body Cup s =W s Tower �— i , Fusible Link 1-7/8"(48 mm)+1-3/8"(9 mm) ,f Nominal face of fitting to ceiling IIiI1 11 Deflector(retracted) 1114114-7 , —r 0.141. _ \\\\\\\ I _ _ 1 iiiiiii x 3/16"(5 mm) Pin(extended) - Il i �1 Deflector(extended) � 'i' Fi Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Max.Coverage Areat21 Flow Pressure ft.x ft. gpm psi (m x m) (Um in) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 5 of 7 February 2017 www.reliablesprinkler.com Cover Plate Finishesi'> Table H Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Custom Color Clad(3) Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss,unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates are not listed or approved as corrosion resistant.Stainless steel clad cover plates are not available perforated. Installation Dimensions TableJ Recommended Min.to Min.to Max. Cover Plate Cover Plate Max.Face Dropped Deflector Cover Hole Diameter Cover Plate Sprinkler Diameter Adjustment of Fitting to Distance below Model Plate inch in Ceiling inch Ceiling(1) Ceiling Temperature Model inch Rating (mm) (mm) (mm) inch inch (mm) (mm) RFC30 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC43 RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC49 135°F2 RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2" brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. 2. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F(66°C). Inst.Ilat of n Model RFC series sprinklers are intended to be installed in ac- Donot exceed the maximum recommended torque.Exceeding cordance with NFPA 13, NFPA 13R, or NFPA 13D,as well as the the maximum recommended torque may cause leakage or im- requirements of applicable authorities having jurisdiction. Mod- pairment of the sprinkler. Use care when inserting or removing el RFC series sprinklers must not be installed in ceilings with the wrench from the sprinkler to avoid damage to the sprinkler. positive pressure in the space above.Ensure that the 4 slots in the cup are open and unobstructed following installation.Model Install the cover plate by hand by pushing the cover plate into RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it should remain on the sprinkler until installed.The protective cap is tight against the ceiling. should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Ap I ication Model RFC series sprinklers are installed with the Model FC Model RFC series sprinklers are intended for installation where wrench.The use of any other wrench to installed Model RFC se- residential sprinklers are permitted or required by NFPA 13, ries sprinklers is not permitted and may damage the sprinkler. NFPA 13R, and NFPA 13D.The sprinklers are concealed pen- Temporarily remove the protective cap during installation of the dent residential sprinklers. sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body.D o not wrench any other part of the Model RFC 30, RFC43,and RFC49 sprinklers are available in sprinkler/cup assembly.The Model FC wrench is designed to ordinary temperature classification for installation where the be turned with a standard 1/2" square drive.Tighten the sprin- Maximum Ceiling Temperature does not exceed 100°F (38°C). kler into the fitting after applying a PTFE based thread sealant Model RFC58 sprinklers are available in either ordinary or in- to the sprinkler's threads.Recommended installation torque is 8 termediate temperature classification for installation where the to 18 ft/lb(11 to 24 N/m). Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Bulletin 006 Rev.K Page 6 of 7 February 2017 www.reliablesprinkler.com Wrench ` Model FC Maintenance Guarantee Model RFC series sprinklers should be inspected and the For the Reliable Automatic SprinklerCo., Inc. guarantee,terms, sprinkler system maintained in accordance with NFPA 25. Do and conditions,visit www.reliablesprinkler.com. not clean sprinklerswith soap and water,ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace Patents any sprinkler cover plate assembly which has been painted (other than factory applied)or damaged in any way.A stock of Model RFC30,RFC43,RFC49,and RFC58 sprinklers are spare sprinklers should be maintained to allow quick replace- covered by U.S. Patent No. 9,248,327 and U.S. Patent No. ment of damaged or operated sprinklers. Prior to installation, 7,275,603. sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to Model RFC30 and RFC43 sprinklers are additionally covered sprinklers that would cause improper operation or non-oper- by U.S. Patent No. 8,776,903. ation. Ordering Information Listings and Approvals Specify the following when ordering. Listed by Underwriters Laboratories, Inc. and UL Certified for Sprinkler Canada(cULus) • Model (RFC30,RFC43,RFC49,RFC58) UL • Temperature Rating Listing Category Cover Plate • ModelRFC • Temperature Automatic Sprinkler Rating UL Guide Number • Finish(See Table H) Sprinkler Wrench • Model FC VKKW CO z Co Co CO N Bulletin 006 Rev.K �e1i��1e Page 7 of 7 February 2017 www.reliablesprinkler.com Bulletin 176 Rev.C co ® Model F1 Reliable Residential Sprinklers for Design Densityof .10 gpm/ft2 Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: . .. r\RI yip` T. F1 Pendent t � 2. F1 Res 30 Recessed/F2 3. F1 Res 30 Recessed/FP - . 4. F1 Res 30 CCP Pendent Fl Res30, 49, 58 & 76 Fl Res30, 49, 58 & 76 5. F1 Res 49 Pendent Recessed Pendent/F1 Recessed Pendent/FP 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP 8. F1 Res 49 CCP Pendent • 9. F1 Res58 Pendent Aa : 10. F1 Res 58 Recessed Pendent/F1 11.F1 Res 58 Recessed Pendent/FP 12. F1 Res 58 CCP Pendent 13. F1 Res 44 & 58 HSW Fl Res 30, 49, 58 & 76 F1 Res58 HSWX 14. F1 Res 44 & 58 HSW Recessed HSW/F2 CCP Pendent 15. F1 Res 58 HSWX 16. KRes58HSWX 17.F1 Res 44 SWC t 18. F1 Res 76 Pendent 19. F1 Res 76 Recessed Pendent/F1 \ '� �I 20.F1 Res 76 Recessed Pendent/FP 21. F1 Res 76 CCP Pendent F1 Res 44 & 58 F1 Res 44 SWC Listings & Approvals Recessed HSW/F2 1. Listed by Underwriters Laboratories Inc. and The 3mm glass-bulb pendent sprinklers permit the ef- UL Certified for Canada (cULus) ficient use of residential water supplies for sprinkler cover- 2. NYC MEA 258-93-F age in residential fire protection design. UL Listing Category Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the water- Residential Automatic Sprinkler way for water flow onto the deflector, evenly distributing UL Guide Number the discharged water to control a fire. VKKW Technical Data: Patents • Thermal Sensor: Nominal 3mm glass-bulb US Patent No. 6,516,893 applies to the Model Fl Res 49 • Sprinkler Frame: Brass Casting & 58 Pendent Sprinklers • Sprinklers'Pressure Rating: 175 psi US Patent No. 7,353,882 applies to Model Fl Res 44 & Factory Hydrostatically Tested to 500 psi 58 HSW Sprinklers • Thread Size: 1/2" NPT(R'/2) US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinkler • K-Factor: 3.0(Actual)-Fl Res30 Pendent Sprinkler Patent Pending - Model Fl Res 76 Pendent Sprinkler 4.9(Actual)-F1 Res 49 Pendent Sprinkler 5.8(Actual) - F 1 Res 58 Pendent&HSW/HSWX Product Description Sprinkler Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) 7.6(Actual)-F1 Res76PendentSprinkler combine excellent durability, high sensitivity glass-bulb 4.4(Actual)-F1Res 44HSW Sprinkler and low profile decorative design. • Density: Minimum 0.10 gpm/ft2 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- K=7.6)thatwill provide lower pressure demands for tectionaccording to UL 1626 Standard. Be surethatorifice 0.1 gpm/ft2 densities in NFPA 13 residential applica- size, temperature rating,deflector style and sprinkler type tions. are in accordance with the latest published standards of Example No. 1 The National Fire Protection Association or the approving Room Size= 12 ft x 20 ft(3.6 m x 6.1 m) authority having jurisdiction. Coverage Area= 12 x 20 = 240 ft2(22.3 m2) When using F1 Residential Sprinklers for systems designed Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm to NFPA 13D or NFPA 13R,use listed areaof coverage and Using an F1 Res 49 Pendent Sprinkler, K=4.9 minimum flow and pressure requirements shown in Bulletin Pressure=(24/4.9)2 = 24 psi (1.65 bar) 135. The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover- For systems designed to NFPA 13, use information in this age area using the baseline density of 0.05 gpm/ft2 will bulletin.The number of design sprinklers shall be the most be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- hydraulically demanding sprinklers as required by NFPA fore,the minimum flow required is 24 gpm @ 24 psi(90.8 13. Flows and pressures can not be below the baseline L/min @ 1.65 bar). flows and pressures. NFPA 13 Example No. 2 For residential sprinkler systems designed to NFPA 13, a Room Size= 8 ft x 20 ft(2.4 m x 6.1 m) minimum density of 0.1 gpm/ft2 must be provided over the Coverage Area=8 x 20 = 160 ft (14.9 m2) "design area"that includes the four(4) hydraulically most Flow @ 0.10 gpm/ft density= 160 x 0.10 = 16 gpm demandingg sprinklers for the actual coverage areas bein Using an F1 Res 49 Pendent Sprinkler, K=4.9 protected by the 4 sprinklers. The minimum required dinPressure=(16/4.9)2 = 10.7 psi (0.74 bar) charge from each of the four most hydraulically demanding The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover- sprinklers shall be the greater of the following: age area using the baseline density of 0.05 gpm/ft2 will 1. The flow rates given in the Reliable Residential be 20 gpm @ 16.7 psi(75.7 L/min @ 1.14 bar). Therefore, Sprinkler Technical Bulletins referenced in Table A the minimum flow required is 20 gpm @ 16.7 psi (75.7 for NFPA 13D and 13R as a function of temperature L/min @ 1.14 bar). rating and maximum allowable coverage area(for Example No. 3 actual coverage areas less than or between those R oom Size= 10 ft x 16 ft(3.0 m x 4.91 m) indicated in the respective technical bulletin,it is re- Coverage Area= 10 x 16 = 160 ft2(14.9 m2) quired to use the minimum required flow for the next Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm largest coverage area); or Using an F1 Res 76 Pendent Sprinkler, K=7.6 2. A minimum discharge density of 0.1 gpm/ft2 applied The baseline flow for a 16 ft x 16 ft coverage area is 21 over the"design area"consistingof the four most by gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore,the draulically demanding sprinklers for the actual cov- minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 erage areas being protected by the four sprinklers. L/min @ 0.52 bar). The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage Example No. 4 area indicated in the technical bulletins referenced Room Size= 14 ft x 18 ft(4.3 m x 5.5 m) in Table A. Coverage Area= 14 x 18 = 252 ft2(23.6 m2) Design Note: Using the As = S x L method to de- Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm termine the sprinkler protection area of coverage in (94.6 L/min) accordance with NFPA 13,applythe 0.1 gpm/ft2den Using an F1 Res 76 Pendent Sprinkler, K=7.6 sity to this area to determine the minimum required Pressure=(252/7.6y = 11 psi (0.76 bar) flow. Compare this flow to the minimum 0.05 gpm/ft2 The baseline flow and pressure of an 18 ft x 18 ft cover- cULus Listed flow for the appropriate coverage area age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). in the technical bulletin for the specific residential Therefore,the minimum flow and pressure is 25.2 gpm @ sprinkler. If the flow stated in the technical bulletin 11si (94.6 L/min @ 0.76 bar is less than the calculated 0.1 gpm/ft2 density flow p )' required,the.1 density flow must then be used in the In general residential sprinklers require flows and equation Q=K\F",solving for P,to establish the mini pressures as listed for 0.05 densities to achieve the mum required pressure using the sprinkler K-factor. proper spray pattern so the flows and pressures at Note: In manycasesthelistedflowofindividualresi- 0.05 density are the baseline flows and pressures. dential sprinklers may exceed the required minimum Flows and pressures below the listed 0.05 density 0.05 gpm/ft2 density. Reliable has available resi- shall not be used. dential sprinklers with larger K-factors (K=5.8 and 2. Installation Models F1 Res sprinklers are to be installed as shown. Use of wrenches other than those specified may darn- Model F1, F2 and FP Escutcheons, illustrated herewith, age these sprinklers. are the only recessed escutcheons to be used with Mod- Note: A 'leak tight" sprinkler joint can be obtained with el F1 Res sprinklers. Use of any other recessed escutch- the following torque: eon will void all approvals and warranties. For installing • 3/4" NPT(R3/4)— 14-20 ft-lbs(19 -27.1 N-m) Model F1 Res Pendent sprinklers use only the Model D • 1/2" NPT(R1/2)-8-18 ft-lbs(10.8 —24.4 N-m) sprinkler Wrench;for installing Models F1 Res Recessed Do not tighten sprinklers over maximum recom- Pendent, CCP sprinklers use only the Model GFR2 sprin- mended torque. It may cause leakage or impairment kler wrench; for installing Model F1 Res recessed HSW of the sprinklers. sprinklers use only the Model GFR2 Sprinkler wrench. • Model Fl Res 30, 49, 58 & • Model Fl Res 30, 49, 58 & 76 76 Pendent Recessed Pendent/ Fl/F2 ;. - / , . - i -t .;, 1, I:. r, F1 escutcheon, 3/4" (19mm) adjustment Note: See escutcheon table for dimensions. Y LF 2 i(6J.2 OLE DIA. .-I_ - 1 15/16"DIA. J _ 49.2mm] ± -1 - - t - 1.X 1/2'REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. I- -1 .— FACE OF FITTING TO CEILING DIMENSION: W� � 3/16-15/16(E1 ESCUTCHEON) i ��i ' _� 3/16-11/16(F2 ESCUTCHEON) �_ ADJUSTMENTIIII ®ei'3YO III ////////� IIIIIIII gn �e ql I l-- -��III� } li I I O1JJJ I41 11� � 135FGO2P-4110 2 2]/32"Du. M ....�.� �.�.... (]2.2mm] 135FG03 Fig. 1 Fig. 2 3. Technical Data:F1Res 30 Pendent and Recessed Pendent(SIN R3511) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch(mm) Pressure Temp.Rating Ambient Temp. K Length psi(bar) °F °C °F °C Factor Inch(mm) 1/2"NPT21/64"(8.2) 175(12) 155 68 100 38 3.0 2.25(57) (R1/2) 175 79 **Baseline flows and pressures for 0.05 density Max. Ordinary Temp.Rating Intermediate Temp.Rating Top of Deflector Minimum Max.Coverage area Spacing (155°F/68°C) (175°F/79°C) to Ceiling Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressure Inch(mm) Ft(m) GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); 1/2 recessed using 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11 (0,76) 10(37,8) 11 (0,76) F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows& pressures Technical Data:F1 Res 49 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Escutcheon*,Fl or F2, Data: Actual Thread Orrice Temp. Pressure Ambient K Length Face of fitting to Size Inch Ratingpsi Temp. Inch Adjustment "A" Factor Type Inch(mm) Inch(mm) ceiling (mm) °F °C (bar) °F °C (mm) Inch(mm) 1/2"NPT ,/1e„ 11 155 68 175 12 100 38 4.9 2.25 57 s Min.=3/4(19.1) 3/16-15/16 (R1/2) ( ) 175 79 ( ) 150 66 ( ) F1 /a'"(19.0) Max.=11/2(38.1) (4.7-24.0) **Baseline flows and pressures for 0.05 density F2 1/2'(12.7) Min.=15/16(23.8) 3/16 11/16 Max.=11/2(38.1) (4.7-17.4) *Note:Escutcheons F1 or F2 may be used with Deflector-to- ceiling Model F1 Res 49&58 Recessed Pendent Sprinkler Maximum 1" (25mm)to 4" (100mm) *Deflector-to- ceiling Max.Sprinkler Flow Pressure Sprinkler Maximum 4" (100mm) to 8" (203mm) Spacing Identification Max.Sprinkler Sprinkler ft (m) gpm(Lpm) psi(bar) Number(SIN) Spacing Flow Pressure Identification - 12 x 12(3.6x3.6) 13(49) 7.0(0.48) ft (m) gpm(Lpm) psi(bar) Number(SIN) 14 x 14(4.3x4.3) 13(49) 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4(0.65) 16 x 16(4.9x4.9) 13(49) 7.0(0.48) R3516 14 x 14(4.3x4.3) 16(60.5) 10.6(0.73) 18 x 18(5.5x5.5) 17(64.3) 12.0(0.83) 16 x 16(4.9x4.9) 17(64.3) 12.0(0.83) R3516 20x 20(6.1x6.1) 20(75.7) 16.7(1.14) 18 x 18(5.5x5.5) 19(72) 15.0(1.0) 20x 20(6.1x6.1) 22(83.2) 20.2(1.4) *Note:The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth=7"(178mm) 2.Beam spacing at or greater than 7.5 ft.(2.3m)on center. Technical Data:F1 Res 58 Pendent and Recessed Pendent Sprinkler Temp. Max. Thread Size Nominal Orifice Rating Max. Pressure Ambient Temp. K Sprinkler Length Inch (mm) °F °C psi(bar) °F °C Factor Inch (mm) 155 8 10 38 1"NPT(R1/2) 1/2 (13) 175 7g 175(12) 1b0 66 5.8 2.25(57) **Baseline flows and pressures for 0.05 density I Max.Sprinkler Spacing Flow Pressure Ceiling -to-D d ector Sprinkler Identification ft(m) gpm(Lpm) psi(bar) Inch (mm) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) 7.6(0.53) - 1-4 16 x 16(4.9x4.9) 16(61) 7.6(0.53) (25-100) R3513 18 x 18(5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1x6.1) 22(83.3) 14.4(1.0) **Calculate for a .10 density but in no case go below the baseline flows& pressures 4. Technical Data:F1 Res 76 Pendent and Recessed Pendent Sprinkler Max. Escutcheon*,Fl or F2, Data: Nominal Max. Sprinkler Thread Temp. Ambient K Face of fitting Oriice Pressure Length Adjustment "A" Size Inch(mm) Rating psi(bar) Temp. Factor Inch(mm) Type Inch(mm) Inch(mm) to ceiling °F °C °F °C Inch(mm) 3/4"NPT 17/32(13.5) 155 68 175(12) 100 38 7.6 2.25(57) F1 3/4(19.0) Min.=3/4(19.1) 3/16-s/l6(4.7-24.0) (R3/4) 175 79 150 66 Max.=11/2(38.1) F2 1/2(12.7) Min.=16/16(23.8) 3/16-11/16(4.7-17.4) *Baseline flows and pressures for 0.05 densityMax.=11/2(38.1) Max.Sprinkler Sprinkler Spacing Flow Pressure Identification *Calculate for a .10 density but in no case go ft(m) gpm(Lpm) psi(bar) Number(SIN) below the baseline flows& pressures 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 18 x 18(5.5x5.5) 21 7.6(0.53) 20 x 20(6.1x6.1) 23 9.2(0.63) • Model Fl Res 30, 49, 58 & • Model Fl Res 30, 49, 58 & 76 CCP Pendent* 76 Recessed Pendent/ FP ' F ,, ;' � yi *Not listed for corrosion resistance. FP push-on/thread-off escutcheon 2 5/5"DIA.[66.7mm] 2 5/8 [66.7mm] DIA. HOLE IN CEILING 2 5/16"D/A. HOLE IN CEILING 2 5/le DIA. C 58.7mm] [55.7mm] CUP r_.- i _-1 CUP rc 1 1'x1/2'REDUCER L -- -I I I"X 1/2"REDUCER CUP 1 i li Ill � \ I CEILING = -' / 11� 1 1/4"[31.5mm] \ / „A , IIIPiull A MAX. FACE OF FITTING TO FACE OF CEILING L J Ili, il� �. DIMENSION ,11� � CEILING _, J : `4p��a_��`'zt I 1 i/7[3 MAX _ OW , FACE OF FITTING 'A„ iiWii COI/ER ADJUSTMENT B r0 FACE OF ceuNc HEIGHTDIMENSION I kV 3 5/16"DIA. 1/z [13mm]MAX. ;� �' A" 135FG04D [84.1 mm] FP ADJUSTMENT `, ,; Fl RES 30, 49, 58 & 76 CCP PEND. 13SFGOIA Fig. 3 Fig. 4 NOTE: The Fl Res 76 will use a 1" x 3/4" reducer. 5. Technical Data:FlRes 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) CCP Assembly Max. Thread Nominal Orifice Max. Pressure K Sprinkler Length Temp.Rating Ambient Temp. Size Inch(mm) psi(bar) °F °C °F °C Factor Inch(mm) 1/"NPT(R1/2) 21/64"(8.2) 175(12) 135 57 100 38 3.0 2.25(57) *Baseline flows and pressures for 0.05 density Ordinary Temp.Rating Max.Coverage area Max.Spacing (155°F/68°C) Top of Deflector Minimum Ft x Ft(m x m) Ft(m) Flow Pressure to Ceiling Spacing Inch (mm) Ft(m) GPM(L/min) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); 1/2(13mm) recessed 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 11 (37,8) 13.4(0,92) using FP escutcheon For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows& pressures Technical Data:F1 Res 49 CCP Pendent and Recessed Pendent/FP CCP Options Data: Nominal Sprinkler CCP Max. Max. Sprinkler "A" „B„ Thread Orifice Assembly Ambient K Length Cover Size Inch Temp.Rating Temp.Rating Pressure Temp. Factor Inch Adjustment CCP Height (mm) °F °C °F °C psi(bar) °F °C (mm) Inch(mm) Inch(mm) /z(RN�T 7/16"(11) 155 68 135 57 175(12) 100 38 4.9 2.25(57) 1/2(12.7) 15/16(24) 3/16(4.7) 3/4 (19) *Baseline flows and pressures for 0.05 density FP D ata"A": Max.Sprinkler Sprinkler "A" Flow Pressure FP Position Spacing Identification Inch(mm) ft(m) gpm(Lpm) psi(bar) Number(SIN) Max.Recessed 7/16(11) 12 x 12(3.6x3.6) 13(49) 7.0(0.48) Min. Recessed 15/16(24) 14 x 14(4.3x4.3) 13(49) 7.0(0.48) 16 x 16 (4.9x4.9) 14(53) 8.2(0.56) R3516 Note:Sprinklers shown in Fig.3 and Fig. 4 are not suitable for in- 18 x 18 (5.5x5.5) 18(68.1) 13.5(0.93) stallation in ceilings which 20 x 20(6.1x6.1) 20(75.7) 16.7(1.14) have positive pressure in the space above. Technical Data:Fl Res 58 CCP Pendent and Recessed Pendent/FP Nominal Orifice Sprinkler CCP Assembly Max. Pressure Max.Ambient K Sprinkler Thread Size Temp.Rating Temp.Rating Temp. Length Inch Inch(mm) °F °C °F °C psi(bar) Factor °F °C (mm) 1/2" NPT(R1/) 1/(13) 155 68 135 57 175(12) 100 38 5.8 2.25(57) *Baseline flows and pressures for 0.05 density Max.Sprinkler Spacing Flow Pressure Sprinkler Identification ft(m) gpm(Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) 7.6(0.53) 16 x 16 (4.9x4.9) 16(61) 7.6(0.53) R3513 18 x 18 (5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1x6.1) 22(83.3) 14.4(1.0) *Calculate for a .10 density but in no case go below the baseline flows& pressures 6. Technical Data:Fl Res 76 CCP Pendent and Recessed Pendent/FP Sprinkler Temp. CCP Assembly 1 Max.Ambient Sprinkler Thread Size Nominal Orifice Rating Temp.Rating Max. Pressure Temp. K Length Inch(mm) psi(bar) Factor °F °C °F °C °F °C Inch(mm) 3/4" NPT(R3/4) 17/32"(13.5) 155 68 135 57 175(12) 100 38 7.6 2.25(57) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max.Sprinkler Spacing Flow Pressure Sprinkler Identification ft(m) gpm (Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) *Calculate for a .10 density but in 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 no case go below the baseline flows 18 x 18(5.5x5.5) 22 8.4(0.58) & pressures 20 x 20(6.1x6.1) 25 10.8(0.74) • Model Fl Res 44 & 58 HSW • Model Fl Res 44 & 58 Recessed HSW/F2 '. 4 lig 7114119C1.11: lb ' R 7= q�ti ' t 41 x \ \ gif ' 1 4Jr r i F1 Res44&58 Recessed HSW/F2 Technical Data:Fl Res 44 HSW & HSW/F2 Escutcheon,F2, Data: Sprinkler Max. Face of Fitting to Nominal Max. Sprinkler Adjustment Thread Orifice Temp. Pressure Ambient K Length Type Inch(mm) wall Size Inch(mm) Inch(mm) Rating psi(bar) oTemp. Factor Inch (mm) °F C F °C F2 1/2(13) 3/16-11/16(4.7-17.4) Yz"NPT 3/a(10) 155 68 175(12) 100 38 4.4 2.45(62) (R1/2) 175 79 150 66 *Baseline flows and pressures for 0.05 density "A" Max.Sprinkler Sprinkler Sprinkler Ceiling-to- Flow Pressure Spacing Temp.Rating Identification ft(m) Deflector °F(°C) gpm (Lpm) psi(bar) Number(SIN) Inch(mm) 12 x 12(3.6x3.6) 155(68) 175(79) 12(45.4) 7.5(0.52) 14 x 14(4.3x4.3) 155(68) 175(79) 14 (53.0) 10.2(0.71) 16 x 16(4.9x4.9) 4-6 155(68) 175(7 9) 16(60.6) 13.3(0.92) 16 x 18(4.9x5.5) (101-152) 155(68) 175(79) 18(68.1) 16.8(1.16) 18 x 18(5.5x5.5) 155(68) 175(79) 19(72.0) 18.7(1.29) 16 x 20(4.9x6.1) 155(68) 175(7 9) 23(87.1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 155(68) 175(79) 14(53.0) 10.2(0.71) 14 x 14(4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 16(4.9x4.9) 6 12 155(68) 175(79) 17 (64.4) 15.0(1.04) 16 x 18(4.9x5.5) (152-305) 155(68) 175(79) 20(75.7) 20.7(1.43) 16 x 20(4.9x6.1) 155(68) 175(7 9) 23(87.1) 27.4(1.89) *Calculate for a .10 density but in no case go below the baseline flows& pressures 7. • Model Fl Res 44 SWC* f 4"to 12„ [707.60mm To 1 1/4"[31.75mm]Maximum 304.80mm] Face Of Fitting PUSH ON COVER, THEN `._ To Well Dimension w i. TURN TO ADJUST UNTIL t' - 'i p TIGHT AGAINST WALL. �1 may'„' - 1"X 1/2"Reducer Aill '"" i Recommended ,'\ouiii �, Well Hole 2 5/16"" ; r'••-,, 2 5/8,, /8' [58. . i -F--- i�Z-ial zc=;' 3 5/16» [66.68mm] Die. ill , � [84.74mm] i p1)All _r_- - J �l Dia. �� TURN COLLAR UNTIL ; 1 TIGHT AGAINST SPRINKLER 1 27/32» WRENCH BOSS. [42.07mm] 135F007 7/2""[72.7Omm] Not listed for corrosion resistance. Adjustment Fl RES 44 SWC Fig. 5 Technical Data:F1 Res 44 SWC Sprinkler Cover Max. Thread Nominal Temp. Temp. Max. Ambient K Sprinkler Size Orifice Rating Rating Pressure Temp. Factor Length Inch(mm) °F °C °F °C psi(bar) °F °C Inch (mm) 1/2"NPT 3/8(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62) (Rl/2) *Baseline flows and pressures for 0.05 density Max. "A"Ceiling-to- Flow Pressure Sprinkler Sprinkler Spacing Deflector Identification ft(m) Inch(mm) gpm(Lpm) psi(bar) Number(SIN) 12 x 12(3.6x3.6) 13(49.2) 8.7(0.60) 14 x 14(4.3x4.3) 14(53.0) 10.2(0.71) 16 x 16(4.9x4.9) (101-152) 17(64.3) 15.0(1.1) 16 x 18(4.9x5.5) 19(71.8) 18.7 (1.13) 16 x 20(4.9x6.1) 23(87.1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 14(52.9) 10.2(0.71) 14 x 14(4.3x4.3) 6-12 15(56.7) 11.7 (0.81) 16 x 16(4.9x4.9) (152-305) 18(68.1) 16.8 (1.16) 16 x 18(4.9x5.5) 20(75.6) 20.7(1.43) *Calculate for a .10 density but in no case go below the baseline flows& pressures 8. Technical Data:F1 Res 58 HSW & HSW/F2 Sprinkler Max. Escutcheon,F2, Data: Thread Nominal Temp. Max. Ambient K Sprinkler Face of Fitting to Size Orifice Rating Pressure Temp. Factor Length Adjustment wall Inch(mm) °F oC - psi(bar) - °F °C Inch(mm) Type Inch (mm) Inch(mm) 1/2"NPT /2(13) 155 68 175(12) 100 38 5.8 2.45(62) F2 1/2(13) 3/16-11/16(4.7-17.4) (R1/2) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max. Ceiling'-to- Sprinkler Flow Pressure Sprinkler Sprinkler Spacing Deflector Temp.Rating gpm(Lpm) psi(bar) Identification ft(m) Inch(mm) °F(°C) Number(SIN) 12 x 12(3.6x3.6) 155(68) 17 5(7 9) 16(60.6) 7.6(0.53) 14 x 14(4.3x4.3) 155(68) 175(79) 18(68.2) 9.7(0.67) 16 x 16(4.9x4.9) (101-152) _155(68) 175(79) 21 (79.5) 13.2(0.91) 16 x 18(4.9x5.5) 155(68) 175(79) 25(94.7) 18.6(1.28) 16 x 20(4.9x6.1) 155(68) 175(7 9) 29(109.8) 25(1.73) R3533 12 x 12(3.6x3.6) 155(68) 175(7 9) 22(83.3) 14.4(1.0) 14 x 14(4.3x4.3) 6-12 155(68) 175(7 9) 22(83.3) 14.4(1.0) 16 x 16(4.9x4.9) (152-305) 155(68) 175(7 9) 26(98.4) 20.1 (1.39) 16 x 18(4.9x5.5) 155(68) 175(79) 31 (117.4) 28.6(1.97) *Calculate for a .10 density but in no case go below the baseline flows& pressure 9. Technical Data:FlRes 58 HSWX(SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Thread Orifice Pressure Temp.Rating Ambient K Length Identification Size Inch(mm) psi(bar) °F °C ,FempC Factor (mm) Number(SIN) Bulb 1/z"NPT 1/2"(13) 175(12) 155 68 100 38 5.8 2.45(62) RA3533 (R1/) 175 79 150 66 *Baseline flows and pressures for 0.05 density Ordinary Temp.Rating Intermediate Temp. Max. Rating Top of Deflector Minimum Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) to Ceiling Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressure Inch (mm) Ft(m) GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) 18 x 20(5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) 33(125) 32.4(2,23) 1/2(13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 6 to 12(152 to 305); Y (13)recessed 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model Fl Res 58 HSWX(Bulb) 4 FACE OF FITTING TO _:': ` WALL DIMENSION 1 11/16"MIN. � -• [31.8mm] .1.0.: 2 1/4" HOLE DIA. 'A» x [57.2mm] X328 mm] CEILING TO � ~Olk DEFLECTOR 1011#1"X 1/2"REDUCER \ DIMENSION / -rihl ''I al -'— -7---, 1. 1 .., -0 . 1 15/16" DIA.I I I i _ •... ' .-v I [49.2mm] 1111:Wn ��'- a 2 27/32" DIA. 8 r �� } ,y,,, �J [72.2mm] • Model KRes58 HSWX(Link) L-- ANNI I TURN COLLAR UNTIL " TIGHT AGAINST SPRINKLER ` / WRENCH BOSS. Li / 135FG08 f1/2"[13mm] ADJUSTMENT Fl RES 58 HSWX , • FIg. 6 i r � 10. Technical Data:KRes58 HSWX(RA3593) Nominal Max. Max. Sprinkler Sprinkler Thread Orifice Pressure Ambient K Length Identification Size Inch(mm) psi(bar) oTemp. Factor Inch Number(SIN) F °C (mm) Link /2 NPT" 1/2"(13) 175(12) 100 38 5.8 2.45(62) RA3593 (R1/2) *Baseline flows and pressures for 0.05 density Ordinary Temp.Rating I Max.Coverage area Max.Spacing (165°F/74°C) Top of Deflector Minimum Ft x Ft(m x m) Ft(m) Flow Pressure to Ceiling Spacing GPM(L/min) PSI(bar) Inch (mm) Ft(m) 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 20 x 20(6,1x 6,1) 20(6,1) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) Y (13) recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 6 to 12(152 to 305); ' (13)Recessed 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. Maintenance Model F1 Res30, 49, Fl Res58 & F1 Res76Sprin- manufacturer's installation guidelines and the appli- klers should be inspected and the sprinkler system cable installation standard. Where pendent residential maintained in accordance with NFPA 25, 13, 13D, and sprinklers are installed under sloped ceilings having 13R. Do not clean sprinkler with soap and water, Am- a pitch from [4/12] to [8/12], the sprinklers shall be monia or any other cleaning fluids. Remove dust by listed for such use. Deflector-to-ceiling distance list- using a soft brush or gentle vacuuming. Remove any ing shall be 1" to 8" maximum.Sprinkler frame and de- sprinkler which has been painted (other than factory flector shall be of bronze frame construction having a applied)or damaged in any way.A stock of sparesprin- 1" NPT thread. Water seal assembly shall consist of a klers should be maintained to allow quick replacement Teflon* coated Belleville spring washer with top-loaded I of damaged or operated sprinklers. Prior to installation, extruded or cold head cup with 3 mm glass bulb con- sprinklers should remain in the original cartons and taining no plastic parts, and having a temperature rat- packaging until used. This will minimize the potential ing of [155°F (68°C)] [175°F(79°C)]. Sprinklers shall for damage to sprinklers that could cause improper op- have a nominal K-factor of 4.9 & 5.8. Standard finish: erationor non-operation. [Bronze] [Chrome-plated] [White Polyester] [Special Model F1Res 30, 49 & 58 Pendent Sprinkler finish-specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 Specifications (Bulletin 135). Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the I *DuPont R egistered Trademark 11. Model Fl Res 30,49&58 Recessed Pendent/F1, Model Fl Res 30,49&58 Recessed Pendent/F2, plate adjustment. Cover plate temperature rating shall be Model Fl Res 30,49&58 Recessed Pendent/FP 135°F(57°C). A plastic protective cap shall be provided Sprinklers shall be[cULus Listed] [New York City MEA and factory installed inside the sprinkler cup to protect Approved (258-93-E)] low flow residential recessed pen- the sprinkler from damage, which could occur during dent sprinklers engineered to provide a minimum design construction before the cover plate is installed. Standard density of 0.10 gpm/ft2 over the listed coverage area. cover plate finish: [White] [Custom Color-specify]. ]. Con- Listed flows as specified by the manufacturer's technical cealed pendent sprinklers shall be Reliable Model F 1 Res data sheets are to be used. Residential sprinklers shall 49&58 CCP, SIN R3516&R3513(Bulletin 135). be installed in conformance with the manufacturer's instal- Model Fl Res 44, Fl Res 58 Horizontal lation guidelines and the applicable installation standard. Sidewall, Fl Res 58 HSWX & KRes58 HSWX Where pendent residential sprinklers are installed under Residential Sprinkler Specifications sloped ceilings having a pitch from [4/12]to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling Sprinklers shall be [cULus Listed] low flow residen- distance listing shall be 1"to 8"maximum.Sprinkler frame tial horizontal sidewall sprinklers engineered to pro and deflector shall be of bronze frame construction hav vide a minimum design density of 0.10 gpm/ft2 over ing a'/2"NPTthread. Water seal assembly shall consist of the listed coverage area. Listed flows as specified a Teflon* coated Belleville spring washer with top loaded by the manufacturer's technical data sheets are to be I extruded or cold head cup with 3 mm glass bulb contain- used. Residential sprinklers shall be installed in con- ing no plastic parts, and having a temperature rating of formance with the manufacturer's installation guide- [155°F (68°C)] [175°F(79°C)]. Sprinklers shall have a lines and the applicable installation standard. Where nominal K-factor of 4.9 (70). Standard finish: [Bronze] horizontal sidewall residential sprinklers are installed [Chrome-plated] [White Polyester] [Special finish- spec- under sloped ceilings having a pitch from [4/12] to ify]. Recessed escutcheon assembly shall be a steel, [8/12], the sprinklers shall be listed for such use. Sprin- two-piece escutcheon [with 1/2" adjustment (Model F2)] kler frame and deflector shall be of bronze frame con [with 3/4" adjustment (Model F1)] [of push-on and thread struction having a '/2" NPT thread. Water seal assem- offdesignwith'/2"adjustment(Model FP)].Standard finish bly shall consist of a Teflon coated Belleville spring shall be[brass][bright chrome] [white painted]. Residen washer with top-loaded extruded or cold head cup tial recessed pendent sprinklers shall be Reliable [Model with 3 mm glass bulb containing no plastic parts, and F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res having a temperature rating of [155°F (68°C)] [175°F 49 & 58 Recessed Pendent/F2] [Model Fl Res 49 & 58 (79°C)]. The solder element (Link)version, the water Recessed Pendent/FP]SIN R3516&R3513(Bulletin 135). seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed Model Fl Res 30, 49 & 58 CCP Pendent assembly forthe HSWX(Bulb& Link)should be a steel (Concealed) two pieces escutcheon with 1/2" adjustment (Model Sprinklers shall be[cULus Listed] [New York City MEA F2)standard finish should be Bright Chrome and white Approved (258-93-E)] low flow residential concealed painted. The F1 Res 58 HSW is also available with low sprinklers engineered to provide a minimum design den- lead frame.Fl Res58 HSW and HSWX sprinklers shall sity of 0.10 gpm/ft2 over the listed coverage area. Listed have a nominal K Factor of 5.8 and F1 Res 44 a nomi- flows as specified by the manufacturer's technical data nal K factor of 4.4. Standard finish: [Bronze][Chrome- sheets are to be used. Residential sprinklers shall be in- plated] [White Polyester] [Special finish- specify]. stalled in conformance with the manufacturer's installa- Residential horizontal sidewall sprinklers shall be Reli- tion guidelines and the applicable installation standard. able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX& Where pendent residential sprinklers are installed under Model KRes58HSWX, SIN R3531, RA3533& RA3593 sloped ceilings having a pitch from [4/12]to [8/12], the (Bulletin 135). sprinklers shall be listed for such use.Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a I Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a '/2" cover I "DuPont Registered Trademark 12. Model Fl Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Residential recessed pendent sprinklers shall be Reliable Use description for the Model F1 Res 58 horizontal [Model Fl R es 76 Recessed Pendent/F1] [Model Fl Res sidewall sprinkler with the following modifications: Re- 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed place"horizontal sidewall sprinkler" with "recessed hori- Pendent/FP] SIN R7618(Bulletin 135). zontal sprinkler." Add: Recessed escutcheon assembly Model Fl Res 76 CCP Pendent(Concealed) shall be a steel, two-piece escutcheon with 1/2" adjust Sprinklers shall be [cULus Listed] low flow residential ment (Model F2). Standard finish shall be [brass][bright concealed sprinklers engineered to provide a minimum chrome] [white painted] [Special finish— specify]. Resi design density of 0.10 gpm/ft2 over the listed coverage dentia) recessed horizontal sidewall sprinklers shall be area. Listed flows as specified by the manufacturer's Reliable Model F1 Res58/F2, SIN R3513(Bulletin 135). technical data sheets are to be used. Residential sprin- Model Fl Res 76 Pendent klers shall be installed in conformance with the manufac- Sprinklers shall be [cULus Listed] low flow resi- turer's installation guidelines and the applicable installa- dential pendent sprinklers engineered to provide a tion standard. Sprinkler frame and deflector shall be of minimum design density of 0.10 gpm/ft2 over the list- bronze frame construction havinga 3/4"NPTthread. Water ed coverage area. Listed flows as specified by the seal assembly shall consist of a Teflon-coated Belleville manufacturer's technical data sheets are to be used. spring washer with machined or cold head cup with 3 Residential sprinklers shall be installed in conformance mm glass bulb containing no plastic parts, and having a with the manufacturer's installation guidelines and the temperature rating of 155°F(68°C). Cover plate assem- applicable installation standard. Sprinkler frame and bly shall consist of a brass cover plate and copper alloy deflector shall be of bronze frame construction having retainerflange. Method of attaching the cover plate to the a 3A" NPT thread. Water seal assembly shall consist of sprinkler cup shall be a push-on and thread-off design aTeflon-coated Bellevillespringwasherwith machined allowing a '/2" cover plate adjustment. Cover plate tem- or cold head cup with 3 mm glass bulb containing no perature rating shall be 135°F (57°C). A plastic protec- plastic parts,and having temperature rating of[155°F tive cap shall be provided and factory installed inside the (68°C)] [175°F(79°C)]. Sprinklers shall have a nominal sprinkler cup to protect the sprinkler from damage,which K-factor of 7.6. Standard finish: [Bronze][Chrome-plat- could occur during construction before the cover plate ed] [White Polyester][Specialfinish—specify].Residen- is installed. Standard cover plate finish: [White] [Custom tial pendent sprinklers shall be Reliable Model F1 Res Color—specify]. ]. Concealed pendent sprinklers shall be 76,SIN R7618(Bulletin 135). Reliable Model F1 Res76CCP, SIN R7618(Bulletin 135). Model Fl Res 76 Recessed Pendent/F1, Finishesf'> Model Fl Res 76 Recessed Pendent/F2, Standard Finishes Model Fl Res 76 Recessed Pendent/FP Sprinkler Fl, F2,FP Escutcheons Sprinklers shall be [cULus Listed] low flow residen- Bronze Brass tial recessed pendent sprinklers engineered to provide Chrome Plated Bright Chrome Plated a minimum design density of 0.10 gpm/ft2 over the listed White Polyester Coated(2) White Painted coverage area. Listed flows as specified by the manu- Special Application Finishes facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the _ Sprinkler Fl,F2,FP Escutcheons manufacturer's installation guidelines and the applicable Electroless Nickel Electroless Nickel installation standard. Sprinkler frame and deflector shall PTFE(Teflon®)"2 PTFE(Teflon®)" Bright Brass Bright Brass be of bronze frame construction having a 3/4" NPT thread. Black Plated Black Plated Water seal assembly shall consist of a Teflon-coated Bel- Black Paint Black Paint leville spring washer with machined or cold head cup with Off White Off White 3 mm glass bulb containing no plastic parts, and having Chrome Dull Chrome Dull a temperature rating of [155°F (68°C)] [175°F(79°C)]. Other finishes and colors are available on special order. Sprinklers shall have a nominal K-factor of 7.6. Standard 2 Consult factory for details. p cULus listed Corrosion Resistant. finish:[Bronze][Chrome-plated][WhitePolyester][Special finish—specify]. Recessed escutcheon assembly shall be Ordering Information a steel,two-piece escutcheon [with 1/2" adjustment(Mod- Specify: el F2)] [with 3/4" adjustment (Model F1)] [of push-on and 1. Sprinkler Model thread off design with'/2" adjustment (Model FP)]. Stan- 2. Sprinkler Type dardfinishshall be[brass][bright chrome] [white painted]. 3. Temperature Rating 4. Sprinkler Finish I "DuPont Registered Trademark 5. Escutcheon Finish 13. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletinis to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Recycled Reliabl ® (800)431-1588 Sales Offices(800)884289-62004521 Sales Fax v� Paper (914) Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.03/14 P/N 9999970322 Z!!RN® Model 975XL WILKINS Reduced Pressure PrincipleAssembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply.Assembly shall provide protection where a potential health hazard exists. , e'_ Standards Compliance ;a • ASSEO Listed 1013 • IAP MO®Listed d • UL®Classified(less shut-off valves or with OS&Y valves • C-UL®Classified Options • CSA®Certified B64.4 (Suffixes can be combined) • AWWAcompliant C511 ❑ - with full port QT ball valves(standard) • Approved by the F oundationfor Cross Connection ❑ L - less ball valves,male pipe thread Control and Hydraulic Research at the University of ❑ U - with union ball valves Southern California ❑ MS - with integral relief valve monitor switch • NYC MEA 425-89-M VOL 3 ❑ S - with bronze"Y"type strainer ❑ BMS - with battery operated monitor switch Materials ❑ FDC - with fire hydrant connection;2" only Main valve body Cast Bronze ASTM B 584 ❑ FT - with integral male 45°flare SAE test fitting Access covers Cast Bronze ASTM B 584 ❑ TCU - with test cocks up Fasteners Stainless Steel,300 Series ❑ V - with union swivel elbows(3/4"&1") Elastomers Silicone(F DAApproved) ❑ SE - with street elbows(3/4"&1") Buna Nitrile(F DAApproved) Polymers NorylTM,NSF Listed Accessories Springs Stainless Steel,300 series ❑ Air gap(Model AG) 111Repair kits Features Sizes: 3/4", 1", 1-1/4", 1-1/2", 2" 111 Thermal expansion tank(MdI.XT) Maximum working water pressure 175 PSI 111Soft seated check valve(Model 40XL) 111 Shock arrester(Model 1250XL) Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI 111 QT-SET Quick Test F ittingSet End connections Threaded ANSI B1.20.1 ❑ Ball valve handle locks i o`iurQl W00:.11M Relief Valve discharge port: C �b/3/4"- 1" - 0.63 sq. in. 0 O � I 1 1/4" -2" - 1.19 sq. in. O O D - ► C B A G Dimensions&Weights(do not include p kg.) DIMENSIONS(approximate) MODEL 975XL B WITH BALL SIZE A C D E F O VALVES in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg 3/4 20 12 305 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 16 1/8 410 12 5.5 1 25 13 330 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 17 3/8 441 14 6.4 1 1/4 32 17 432 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 22 9/16 573 28 12.7 1 1/2 40 17 3/8 441 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 24 1/16 611 28 12.7 2 50 18 1/2 470 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 26 1/2 673 34 15.4 Zurn Industries,LLC I Wilkins Rev.C 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,F ax805-238-5766 Date:6/14 In Canada I Zurn Industries Limited Document No.BF-975XL 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,F ax905-405-1292 Product No.Model 975XL www.zurn.com Page 1 of 2 Flow Characteristics O Rated Flow(established by approval agencies) MODEL975XL 3/4",1", 1 1/4", 1 1/2" &2" (STANDARD&METRIC) FLOW RVTES(Vs) 6 1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 a 0. 1 v2° 137 N 20 3/4"(20mm) 1"(25mm) 20 1 1/4"(32mm) (40m U) 0 15 15 2"(somm) 103 9 J • w • w y10 10 69 ((n w w w w cc 5 5 35 E_ 0 20 40 60 80 0 50 100 150 200 250 FLOW RATES(GPM) Typical Installation Capacity thru Schedule 40 Pipe Local codes shall govern installation requirements.To be installed in accordance with the manufacturers'instructions Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec and the latest edition of the Uniform Plumbing Code. Unless 1/8" 1 1 2 3 otherwise specified,the assembly shall be mounted at a mini- 1/4" 2 2 3 5 mum of 12" (305mm) and a maximum of 30" (762mm)above adequate drains with sufficient side clearance for testing and 3/8" 3 4 6 9 maintenance.The installation shall be made so that no part of 1/2" 5 7 9 14 the unit can be submerged. ' 3/4 8 12 17 25 1" 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 . STLRM TL-__1 I:vY;LEMIITIIAPROTECTIVE- :Illi lli--� ENCLOSUREloo oo•IjL: : IMINmili B TTERY � _ 4k M�NICH I ••• I til ..' SWITCH' I f, ` 12"MIN. I 30"MIX. M 12"MIN l l 30"MVX H OPTION L IR G P J ITTI(VG Mill W TER DIETER V V H iiiiimsomm. - DRVIN - / U FLOOR) ,' •" �0 I it DIRECTION OF FLOW E iff tit,. i FLOORDRvIN-/ DIRECTION OF FLOW INLET SHUT-OFF INDOOR INSTALLATION OUTDOOR INSTALLATION (Shown w/optional BMS) Specifications The Reduced Pressure Principle Backflow Preventershall be shall be ASSE®Listed 1013, rated to 180°F,and supplied with full port ball valves.The main body and access covers shall be bronze(ASTM B 584),the seat ring and all internal polymers shall be NSF®Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors,the installation shall be supplied with an air gap adapter and integral monitor switch.The Reduced Pressure Principle Back- flow Preventershall be a ZURN WILKINS Model 975XL. Zurn Industries,LLC I Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax905-405-1292 www.zurn.com Page 2 of 2 WILKINS Model 500 WaterPressure Reducing Valve a ZURN,.company with Inte.ralB -.assCheck Valve SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure.The high flow capacity makes this device most suitable for industrial wa- :1° 1,,: ,t,, -/N74 terlines and commercial irrigationsystems.The direct act- ,,, ing integral by-pass design prevents buildup of excessive . system pressure caused by thermal expansion. The bal- FEATURES anced piston design enables the regulator to react in a Sizes: ❑ 1/2" ❑ 3/4" ❑ 1" ❑ 1 1/4" smooth and responsive manner to changes in system flow ❑ 1 1/2" ❑ 2" ❑ 2 1/2" ❑ 3" demand, while at the same time, providing protection from Maximum work ingwater pressure 300 psi inlet pressurechanges. Maximum workingwatertemperature 180° F STANDARDS COMPLIANCE Reduced pressure range 25 psi to 75 psi • Factory preset(fieldset 2 1/2" &3") 50 psi ASSE®Listed 1003 (1/2" thru 2 1/2" ) Threaded connections(FNPT) ANSI B1.20.1 • IAP MO®Listed(1/2" thru 3" ) Copperconnections(FC) ANSI B 16.22 • City of Los AngelesApproved(1/2" thru 3" ) CPVCtailpiece:Max.hotwatertemp. 180°F @ 100 psi CSA®Certified(1/2" thru2") Cold waterrated temp. 73.4°F @ 400 psi MATERIALS OPTIONS(Suffixescan be combined) Main valve body Cast bronze ASTM B 584 ❑ - standardwith single union FNPT inletx FNPT Access covers Cast bronze ASTM B 584 outlet(1/2"thru 2")and less union(21/2" &3") Brass ASTM B 16 ❑ C - copper sweat connection(1/2" thru 2") Fasteners Stainless steel, 300 series ❑ HR - 75 psi to 125 psi spring range, factory set Stem&plunger Cast bronze ASTM B 584 at 85 psi (fieldset 2 1/2" &3") Brass ASTM B 16 ❑ HLR - 10 psi to 125 psi spring range, factory set Elastomers Buna Nitrile(FDA approved) at 50 psi EPDM(FDAapproved) ❑ HT - 210°F maximum temp Cap gaskets Natural vulcanized fibre ❑ L - less integral by-passcheck valve(3/4"-2") Acetal(DelrinTM 500), NSF Listed ❑ LPV - 210°F maximum temp with 10 psi to 35 psi Springs Oil temperedwire,ASTMA 229 spring range, factory set at 20 psi Seat Stainless steel, 300 series ❑ LPC - 180°F maximum temp with 10 psi to 35 psi spring range, factory set at 20 psi - o ❑ SC - sealed cage bell housing and stainless steel , adjustment screw a. ❑ SW - made for salt water service ❑ YSBR - with bronze"Y"strainer on inlet ❑ 510 - 400 psi inlet rating and 75 psi to 125 psi I spring range, factory set at 85 psi B = (fieldset 2 1/2" &3") ❑ P - tappedand plugged forgaugei r , ❑ CP VC - CPVC tailpiececonnection(3/4"-1") D WILKINS ACCESSORIES X500- ❑ Repair kit(rubberonly) c DIMENSIONS &WEIGHTS(do not include pkg.) DIMENSIONS(approximate) SIZE WEIGHT CONNECTIONS A B C D in. mm in. mm in. mm in. mm in. mm lbs. kg. 1/2 15 SINGLE UNION 4 1/2 108 6 152 1 5/8 41 2 3/4 70 3 1.5 3/4 20 SINGLE UNION 4 5/8 118 6 152 _ 1 1/8 _ 29 2 3/4 70 4 2.0 1 25 SINGLE UNION 5 1/8 130 6 7/8 175 1 5/8 41 3 5/16 84 6 3.0 1 1/4 32 SINGLE UNION 6 5/16 160 7 1/4 184 _ 1 3/4 45 4 102 7 3.0 1 1/2 40 SINGLE UNION 8 5/16 211 10 254 1 7/8 48 5 127 14 6.5 I _ 2 50 SINGLE UNION 9 1/2 241 10 3/4 273 2 1/8 54 6 1/2 165 20 9.0 2 1/2 65 LESS UNION 10 254 14 1/2 368 3 76 8 203 28 12.5 3 80 LESS UNION 11 1/8 283 16 406 _ 3 1/2 89 8 - 203 _ 44 20.0 DOCUMENT#: REVISION: REG-500 6/06 Page 1 of 2 FLOW CHARACTERISTICS MODEL 500 1/2" THRU 3" (STANDARD& METRIC) FLOW RATES(Us) 3.2 6.3 9.5 12.6 15.8 18.9 20 ...2::„).... -138 1/2" = 3/4" 1 1/2" - 2" 2 1/2" (n 15 (15mm (20mm AilVer 40mm / 50mm) (65mm 104 d .---...- ...ice LL 10 69 Lt5 �� Ilii 35 u_ 0 0 50 100 150 200 250 300 6.5 PSI LOSE @ 60 GPM FLOW RATES(GPM) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500 may be installed in any position. If installed in a pit or vault, specify the "SC" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). CAUTION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing. i ,11. 01:to •IIEMJI_II� E - MODEL 975XL o • IL_T_, RPZ BACKFLOW PREVENTER OPTIONAL PRESSURE , I GAUGETI • O .1 51,1 ' PROTECTIVE I ; ENCLOSURE E.. S ■om�!� � �D , MODEL SHUT-OFF VALVE ■oIl 1 OPTIONAL PRESSURE 7 ✓ ma GAUGE MiEl ° :'M o.iiIII MODEL DU DIELECTRIC UNION R�� 12"MIN. 30"MAX. 111 i olr ll VERTICAL INSTALLATION —=III-1I rMEL laII-1 I I-III-I I 1 -1 I IJ I I= 111E11 1- I I III IIIIII- -1111=111 III 111=1 111=III=' MODEL 500 TO HANDLE LOW -III= IIL- -III, =III-'' --iil ITI DEMANDS(SET @ 65 PSI) DIRECTION OF FLOW aliminiontsinglik TYPICAL INSTALLATION 1 1 A • 1110 is ail ii s ■.■ MODEL 500FC TO HANDLE DIRECTION OF FLOW HIG H DEMANDS(SET @ 55 PSI) SPECIFICATIONS BATTERY INSTALLATION The Pressure Reducing Valve shall consist of a bronze body and bell housing, a separate access cover for the plunger and a bolt to adjust the downstream pressure.The bronze bell housing and access cap shall be threaded to the body and shall not require the use of ferrous screws.The assembly shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions. The assembly shall be accessible for maintenance without having to remove the body from the line. The Pressure Reducing Valve shall be a WILKINS Model 500. Page 2 of 2 WILKINS a Zurn company,1747 Commerce Way,Paso Robles,CA 93446 Phone:805/238-7100Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga,Ontario L4V 1L2 Phone:905/405-8272Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) - Website: http://www.zurn.com