A18-0070_Approved Documents_1544571089.pdf
75 South Frontage Road Fire -Construction Permit West, TOWN OF VAIL A18-0070 Vail, CO 81657 Issued: 12/11/2018 TOWN of VAILOFOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 714 LIONSHEAD PL 4F (210107205009) Unit#:4F ParcelNumber: 210107205009 L egalDescription: Subdivision: MARKLODGE Unit:4-F Contacts ContactType: Applicant Full Name: LarryWells Address: 6786 S Revere PkwySte 110 Centennial,CO 80112 Phone: 3039865900 ContactType: PropertyOwner FuIlName: FLEISCHER,WILLIAM E.&SHARON K. Address: 1645 CAMBRIDGE DR 4-F LEBANON, PA 170427500 Phone: None Contractor Contractor Type: Alarm Company: Alarmspecialists, Inc. State License#: 18-B-06506 Phone: 303-986-5900 Projectlnformation ProjectName: Vail MarriottRenovation2018 ProjectDescription: Condo 593/595 fire alarm tenantfinish. Fees Paid Account:001-0000.31111.00-Fire Alarm PermitFee Fee Amount: $377.00 Account:001-0000.31123.00 Fire Alarm ReviewFee Fee Amount: $288.00 TotalPaid: $665.00 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # A18-0070 Date Printed: 12/07/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0070 Status: Created Permit Number: Date Started: 12/07/2018 Permit Type: Fire-Construction Permit Subc ases Fire Alarm Lot Number: 4&7 Property: 714 LION SHEAD PL 4F (210107205009) Contacts Contact Type: Applicant Company Name: Alarmspecialists,Inc. Full Name: Larry Wells Address: 6786 S Revere Pkwy Ste 110 Centennial, CO 80112 Email: lwells@alarmspec.com Contact Type: Property Owner Full Name: FLEISCHER,WILLIAM E.&SHARON K. Address: 1645 CAMBRIDGE DR 4-F LEBANON,PA 170427500 Permit Fees Fee Information Account Amount Fire Alarm Permit Fee 001-0000.31111.00 $300.00 Fire Alarm Permit Fee 001-0000.31111.00 $77.00 Fire Alarm Review Fee 001-0000.31123.00 $288.00 Payment Information Date Paid Payment Type Amount Fire Alarm Permit Fee 12/07/2018 Credit Card $77.00 Paid By: -N otes:visa-larry wells Fire Alarm Review Fee 12/07/2018 Credit Card $288.00 Paid By: -N otes:visa-larry wells Fire Alarm Permit Fee 12/07/2018 Credit Card $300.00 Paid By: -N otes:visa-larry wells FEE TOTAL $665.00 AMOUNT PAID $665.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 12/07/2018 -2:08:34 PM-Generated by:cgodfrey 1/ 1 EDWARDS Catalog►Intelligent Input-Output cEoWARDS United Technologies LIFE SAFETY &. INCIDENT MANAGEMENT Riser Monitor • Modules . . MRM1, RM1 Z l s 4 '118 • • .11 ® MEA 730021057. S® Overview Standard Features SIGA-RM1 and MRM1 Riser Monitor Modules are intelligent • Adjustable time delay analog addressable devices that form part of EDWARDS's Signa- ture line of products.The actual operation of the SIGA-RM1 and • Monitors audio power or telephone risers MRM1 is determined by the"personality code"selected by the Reports a trouble condition when voltage on the riser drops installer,which is downloaded to the module from the Signature below the trouble threshold. loop controller during system configuration. • Plug in (UIO)or standard 2-gang mount Depending on their assigned personality, Riser Monitor Modules UIO versions allow quick installation where multiple modules may be used to monitor telephone risers or 70 Vac audio,25 Vac are required.The 2-gang mount version is ideal for remote audio,or 12 Vdc to 24 Vdc risers. locations that require a single module. Upon the loss of a signal,the fire alarm control panel indicates • Automatic device mapping an alert status.The Riser Monitor Module requires one module Signature modules transmit information to the loop controller address. regarding their circuit locations with respect to other Signature devices on the wire loop. • Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC,or the SIGA-PROSignature Program/Service Tool. There are no switches or dials to set. • Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties;twisted or shielded wire is not required. • Non-volatile memory Permanently stores serial number,type of device,and job number.Automatically updates historic information including hours of operation, last maintenance date,number of alarms and troubles,and time and date of last event. Page 1of4 DATA SHEE- E85001-0535 Not to be used for install,. Issue 1 Application Installation The SIGA-RM1 mounts to a standard North American two-gang The SIGA-RM1:mounts to North American 2-1/2 inch(64 mm) electrical box,making it ideal for locations where only one module deep 2-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square is required. Separate I/O and data loop connections are made to boxes with 2-gang covers and SIGA-MP mounting plates.The each module. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) wire size. The SIGA-MRM1 is part of the UIO family of plug-in Signature Series modules.It functions identically to the SIGA-RM1, but takes ;; advantage of the modular flexibility and easy installation that char- 0 0 acterize all UIO modules.Two-and six-module UlO motherboards `� 00� are available.These can accommodate individual risers for each re,,___„„„,„„ "oon-board module,or risers that are shared by any combination of its UIO modules.All wiring connections are made to terminal o' �i � - blocks on the motherboard. UIO assemblies may be mounted in o` .�tj j ,.._Q EDWARDS enclosures. jam, ®, ., - 4,,;", ,„ _A, Electronic Addressing The loop controller electronically addresses each module saving 1` valuable time during system commissioning. Setting complicated switches or dials is not required. Eachmodule has its own unique SIGA-MRM1:mount the UIOxR motherboard inside a suitable serial number stored in its"on-board memory".The loop control- EDWARDS enclosure with screws and washers provided. Plug the ler identifies each device on the loop and assigns a"soft"address module into any available position on the motherboard and secure to each serial number. If desired,the modules can be addressed the module to the motherboard with the captive screws.Wiring using the SIGA-PRO Signature Program/Service Tool. connections are made to the terminals on the motherboard(see wiring diagram).UIOxR motherboard terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Personality Codes u10 Motherboard — Signature modules require the Signature loop controller to down- 1 6-32 load the personality code that determines how it will operate. Seiews ping The Riser Monitor Module provides personality codes 23 and 24, r — =rim= which are described below. -- -11--4.0 (factory Plug-in(U10) I Mod(`�Captive PersonalityCode 23:Riser Monitordefault) . Personality code 23 configures the Riser Monitor Module to mo ni- __ _ tor 70 Vac audio,25 Vac audio,or 12 Vdc and 24 Vdc risers.A — trouble condition is reported back to the panel wherever the volt- fi =1iMEMII age on the riser drops below the trouble threshold.The hardware #6 Flat washers jumper on the Riser Monitor Module must be configured for either _ —Cabinet or electrical enclosu re 70 Vac or 25Vac/24Vdc/12Vdc. Personality Code 24:Telephone Riser Monitor Personality code 24 configures the Riser Monitor Module to Testing & Maintenance monitor telephone risers.A trouble condition is reported back to The module's automatic self-diagnosis identifies when it is defec- the panel whenever voltage on the riser drops below the trouble tive and causes a trouble message.The user-friendly maintenance threshold. program shows the current state of each module and other perti- The delay time from when the device falls below the trouble nent messages. Single modules may be turned off(de-activated) threshold to when it sends a trouble signal to the panel is user temporarily,from the control panel. definable in the appropriate data entry program.A delay of 5 to 75 Scheduled maintenance(Regular or Selected)for proper system seconds can be assigned to the device;the default delay period is operation should be planned to meet the requirements of the 15 seconds. Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Warnings & Cautions Compatibility This module will not operate without electrical power.As fires fre These modules are part of EDWARDS's Signature Series intelligent quently cause power interruption,we suggest you discuss further processing and control platform.They are compatible with EST3, safeguards with your fire protection specialist. EST3X and iO Series control panels. EDWARDS recommends that these modules be installed accord- ing to latest recognized edition of national and local fire alarm codes. Page2of4 DATA SHEET E85001-0535 Not to be used for installation purposes. Issue 1 Typical Wiring (SIGA-RM1) Typical Wiring (SIGA-MRM1) Modules will accept#18 AWG(0.75mm2), #16 (1.0mm2), #14 Modules will accept#12 AWG(2.5mm2), #18 AWG(0.75mm2), AWG(1.50mm2)and#12 AWG(2.50mm2)wire sizes. Note:Sizes #16 (1.0mm2), and#14 AWG(1.50mm2)wire sizes.Note:Sizes #16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for #16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature LoopController catalog sheet ease of installation.See Signature LoopController catalog sheet for detailed wiring requirement specifications. for detailed wiring requirement specifications. Jumper seItlogs (-r Telephone riser 1 II 0 JPt OR(do not connect b othrisers to one module) 0 0 I 've I (d�L 70 Vac or 25 Vac/24 Vdc/12 Vdc Note:Leave ihejumper out fortelephone riser operation. 3 M Green LED(Normal) 1 2 3 4 Riser Monitor Module Red LED(Active) 77 .Green LED(Normal) Q , ��� Fr' U106 or UIO6R motherboard 2 ..-- Data In+ Q RM1 �m A 4 Data 1 3 I p T614 0 0 Circuit 2 1 I 0 8 7 6 5 4 3 2 1 T67 No connections required 00100 114111)0 +_ Dela Out J `� — c`i� O]3 AAA--�� .72 Q]1 II/I ii TB15 (+) I Data out(+)) ANo connections required mm. Remove motherb oar4umpers. �I 70 Vac or 25 Vac/24 Vdc/12 Vdc )})}To Signature device / (-) Data out(+) OR(do not connect both risers to one module) Notes \ (0) Detain(-) From Signature Qj Maximum#12 AWG(2.5 mm')wire;Minimum#18 AWG(0.75 mm') y Telephone riserloop controller (-) — I Detain(+) ff or previous device Q See the loop controller installation sheet for wiring specifications. Notes IJ A Power-limited if the source is power-limited.If the source is nonpower-limited, maintain a space of 1/4 inch(6.4 mm)from power-limited wiring.Otherwise,use Qi 25 W,max per wire FPL,FPLP,FPLR,or an equivalent in accordance with the National Electric A#12 AWG(1.5 mm')max; Code. #18 AWG(0.75 mm')min Q 16 mA,max The UIO6R does not come with T614. QSee the Signature loop controller installation A The U106 does not come with TB8 through TB13. sheet for wiring specifications. 5 All wiring is supervised and power-limited. 7 All wiring is supervised. 8 Wire the Riser Monitor Module in accordance with NFPA70-1999,National Electric Code 760-54(a)(1),exception no.2 and no.3. Signature Series Overview The Signature Series intelligent analog-addressable system from E D- the SDC during system configuration and are indicated during device map- WARDS is an entire family of multi-sensor detectors and mounting bases, ping. multiple-function input and output modules,network and non-network Standalone Operation—A decentralized alarm decision by the device is control panels,and user-friendly maintenance and service tools.Analog guaranteed.Onboard intelligence permits the device to operate in stan- information from equipment connected to Signature devices is gathered dalone(degrade)mode.If Signature loop controller CPU communications and converted into digital signals.An onboard microprocessor in each fail for more than four seconds,all devices on that circuit go into stan- Signature device measures and analyzes the signal and decides whether dalone mode.The circuit acts like a conventional alarm receiving circuit. or not to input an alarm.The microprocessor in each Signature device pro- E achSignature device on the circuit continues to collect and analyze vides four additional benefits—Self-diagnostics and History Log,Automatic information from its slave devices.When connected to a panel utilizing Device Mapping,Stand-alone Operation and Fast,Stable Communication. standalone operation,modules with their"personality"set as alarm devices Self-diagnostics and History Log—E achSignature Series device con- (IDC)will alarm should their slave alarm-initiating device activate. stantly runs self-checks to provide important maintenance information.The FastStable Communication—Built-in intelligence means less info rma- results of the self-check are automatically updated and permanently stored tion needs to be sent between the device and the Signature Data Controller in its non-volatile memory.This information is accessible for review any (SDC).Other than regular supervisory polling response,Signature devices time at the control panel,PC,or using the SIGA-PRO Signature Program/ only need to communicate with the SDC when they have something new Service Tool. to report.This provides very fast control panel response and allows a lower Automatic Device Mapping—The Signature Data Controller(SDC)learns baud rate(speed)to be used for communication on the circuit.The lower where each device's serial number address is installed relative to other de- baud rate offers several advantages including: vices on the circuit.The SDC keeps a"map"of all Signature Series devices • Less sensitivity to circuit wire characteristics. connected to it.The Signature Series Data Entry Program also uses the • Less sensitivity to noise glitches on the cable. mapping feature.With interactive menus and graphic support,the wired cir- • Less emitted noise from the data wiring. cuits between each device can be examined.Layout or"as-built"drawing •Twisted or shielded wiring is not required. information showing branch wiring(T-taps),device types and their address Diagnostic LEDs—Twin LEDs on most Signature devices provide visual are stored on disk for printing hard copy.This takes the mystery out of the indication of normal and alarm-active conditions.A flashing green LE D installation.The preparation of"as-built"drawings is fast and efficient. shows normal system polling.A flashing red LED means the module is Most Signature modules use a"personality code"selected by the installer in alarm-active state.Both LEDs on steady indicates alarm-active state— to determine their actual function.Personality codes are downloaded from standalone mode. Page3of4 DATA SHEET E85001-0535 Not to be used for installation purposes. Issue 1 Specifications --t WAR DS North American 21/2 inch(64 mm)deep 2-gang box;11/2 inch(38 mm) Mounting (SIGA-RM1) deep 4 inch square box with 2-gang cover and SIGA-MP mounting plates LIFE SAFETY&INCIDENT MANAGEMENT Mounting (SIGA- MRM1) Plugs into UIO2R,UIO6R or U106 Motherboards Contact us... Current Email: edwards.fire@fs.utc.com Standby 200 pA Web: Edwards-fire.com Activated 200 pA Maximum Input EDWARDS is a UTC brand. Voltages 12 Vdc+15% 1016 Corporate Park Drive Riser monitor 24 Vdc+15% Mebane,NC 27302 25 Vac+15% 70 Vac+15% ©2016 United Technologies Corporation. 28 Vdc All rights reserved. Telephone Input Currents 12 Vdc 10 mA dc 24 Vdc 10 mA do 25 Vac 10 mA rms 70 Vac 10 mA rms Telephone 24 Vdc 20 mA dc Riser loading 70 Vac Z>11k Ohm 25 Vac Z>1k Ohm 24 Vdc R>2.4k Ohm(2 amps) 12 Vdc R>1.2k Ohm Telephone R>1.2k Ohm,Z>1.2k Ohm Trouble Threshold Approximately 25%of riser input Wiring Terminations Suitable for#12 to#18 AWG(2.5 mm2 to 0.75mm2) Personality Codes Two Selectable Codes Available Address Requirements Uses One Module Address Operating Voltage 15.2 to 19.95 Vdc Construction High Impact E ngineeringPolymer Storage and Operating Operating Temperature:32°F to 120° F(0°C to 49°C) Environment Storage Temperature: -4°F to 140° F(-20°C to 60°C) Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled; On-board Red LED-Flashes when in alarm/active Compatibility Use With:Signature LeopController Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-RM1 Riser Monitor Module(Standard Mount) -UL/ULC Listed 0.5 (0.23) SIGA Riser Monitor Module(Plug-in) -UL/ULC Listed 0.18 (0.08) MRM1 Related Equipment 27193-21 Surface Mount Box-Red,2-gang 2.0(1.2) 27193-26 Surface Mount Box-White,2-gang 2.0(1.2) SIGA- Universal Input-Output Module Board w/Riserinputs-TwoModule 0.32 (0.15) UIO2R Positions SIGA- Universal Input-Output Module Board w/Riser Inputs-Six Module 0.62 (0.28) UIO6R Positions SIGA-U106 Universal Input-Output Module Board -Six Module Positions 0.56 (0.25) MFC-A UL listed cabinet for mounting releasing modules,red with white"FIRE". 7.0 (3.1) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page4of4 DATA SHEET E85001-0535 Not to be used for installation purposes. Issue 1 EDWARDS Catalog► Intelligent Initiating bWARDB c`United Technologies LIFE SAFETY &. INCIDENT MANAGEMENT /71/MrImr /// Sounder Bases � ' � -� 41N It ), SIGA-AB4G, SIGA-AB4G-LF, "- SIGA-AB4GT, SIGA-TCDR SIGA-AB4G-LF SIGA-AB 4GT Ire � 0 I) Lc S853 SI GA-AB 4G 7300-1657:0222 7300-1657:0322 7300-1657:0308 Overview Standard Features The Signature Series AB 4Gsounder bases add audible output • Low frequency model available functions to any Signature Series detector. B asescan operateas Code-compliant 520 Hz output. independent local alarms,or as part of a zone or system alarm • Temporal or steady tone with synchronizedaudible output. Jumper selects steady or synchronizedtemporaloutput. Three models providea full range of features that meet application • High or low dB output needs and mandated code-compliant requirements: Jumper selects low or high dBAoutput. SI GA-AB 4Gbases p rovidesounder capability to Signature Series • Single or group operation single-function smoke detectors.They are not intended for use Optional polarityreversing module configures base for group with combination smoke/COdevices in Fire-plus-COmode. alarm output. SIGA-AB4GT bases providesounder capability to Signature • UL268 and UL464 listed Series single-function smoke detectors,as well as combination UL listing under smoke detectorand audible signal standards smoke/COdetectorswhen used with a SIGA-TCDR Temporal allows applicationas smoke alarm and/oraudible signal. Pattern Generator. • Attractive installation SIGA-AB4G-LF bases provide520 Hz low frequency sounder Flush mount to a wide selection of North American boxes or capability to Signature Series single-function smoke detectors,as surface mount to optional custom-matchedbox. well as combination smoke/COdetectorsin Fire-plus-COmode when used with a SIGA-TCDRTemporal Pattern Generator.The SIGA-AB4G-LF is suitable for app licationsrequiring low frequency audible tones. All bases are co mpatib lewith first and second generationSigna- ture Series intelligent detectorswhen properly configured. SIGA-AB 4Gsounder bases match the finish of Signature Series devices,and the sound output slots complement the air entry openings of the detector.The result is a compact unit with an at- tractive appearance. Page 1 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 Application SIGA-TCDRTemporal Pattern Generator Signature Series AB 4Gsounder bases are for use with Signature The SIGA-TCDRTemporal Pattern Generato ris an address- Series detectorsin ap p licationswhere localized or group alarm able device that generatesCO and fire signal sound patternsfor signaling is required.They are listed by Underwriters Laboratories AB 4GTand AB4G-LF sounder bases.The control panel sends under the UL268 and UL464 standards,allowing their application synchronization and channel commands to the SIGA-TCDR;the where both life safety alarmsand/ornotification appliancesare channel selection determines the pattern.In the U.S. Channel 1 required. is TC3 and Channel 2 is TC4.In Europe,Channel 1 is TC4 and Channel 2 is TC3(in case both channels are activated Channel 1 Programming and Field Configuration has priority).Other markets depend on local requirements. Each AB4Gbase uses the same address and programminglabel Temporal patterns as the detector it supports. Name Code L Used for AB 4Gsounderbasescan be set to simplyoperate according to the TC4 NFPA 720 CO state of its detector,or configuredthroughsystemprogramming to TC3 NFPA 72 Fire operate in conjunctionwith all so underbaseson the same circuit. The SIGA-TCDR module uses two addresseson the signaling line They can also be controlled by program rules.Available operating circuit(SLC).Address 1 is tied to Channel 1; Address2 is tied to modes are determined by the systemthat supports the Signature Channel 2. data loop. AUX RISER IN+ AUX RISER OUT+ B asesmay be configured in the field foreither high or low dB out Aux RISER IN— Aux RISER OUT- put.When used forfire alarm-onlyapplications(i.e.: not with CO — — — — detecto rs),AB 4G bases may be configured fo rsteady or temporal 0 Q output.The default setting is high dB with temporaloutput. 0 [.7.7.7.7 8 7 6 5 Group Activation and Sychronization TCDR AB 4Gsounder bases on the same circuit may be activated as a O group or zone with the use of a SIGA-CRR polarityreversal mod- ule, and the group or zone may be synchronizedaudible output 0 with the use of a G1M-RM signal master. 4 3 2 1 D ♦ ♦ o © Combination Smoke/CO Applications From previousdevice ' To next device SIGA-AB4GT and SIGA-AB4G-LF audible bases may be used SLC_IN+ sLc ouT+ with combination smoke/COdetectorswhen a SIGA-TCDRis installed on the same Signature data loop. SLC_IN— SLC_OUT- The output of these bases is field-configurable for FireAlarm 1. Use a power-limited and regulated 24 VDC primary or auxiliary powersupply that mode,or FireAlarmplus CO Alarm mode.The SIGA-AB4G-LF is UUULC listed for fire protective signaling systems. has two o peratingmodes:fire output only,wherethe unit pro 2. Powerout to AB 4GTsounder base or listed EOLrelayand supervisingmodule duces a T3 tone;and,a Fire-plus-COmode.In the Fire-plus-CO mode,the NAC circuit requiresa SIGA-TCDR module to generate Depending on the type of alarm,the panel can select the cor- and synchronize the TC3 and TC4 tones.These two distinctive responding patternand send the activationcommand to the tones are necessary to differentiate fire alarm signals fromCO SIGA-TCDR. alarm signals. To control all sounder bases in the loop, use a SIGA-CRR module. Depending on the system supporting the Signature loop,the base The panel sends a signal to the SIGA-CRR causing it to reverse can follow the state of the device it supports,or be co ntro Iledby polarity.With the polarityon the riser reversed, all the sounder p rogramrules. bases on this loop activate.The SIGA-TCDR maintains synchroni- zation by processingthe SYNC commands fro mthe loop control- Low Frequency Applications ler. The low frequency model(SIGA-AB4G-LF),features a distinctive 520 Hz signal and is ideal for hotels,do rmito ries,and other co m- EDWARDS-ecommendsthatfirealarmsystemsandtheirdevices mercialsleeping occupancies.This base can be set forlow dB alwaysbe installed in accordance with the latestrecognizededi- output with a jumper cut that reduces audible output by about 4 tion of national and local fire alarm codes. dB.Forcommericalsleeping rooms,most codes and standards require75 dBA-fast at the pillow. Page 2 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 Installationand Mounting Configuration and Wiring Flush Mounting I The sounderbaseflush mounts into 2-1/8 inch(54 mm)deep SIGA-AB4GT, o p SIGH-AB4G-LF: SI GA-AB4G, ®J ® Output Modeumper cuts standard NorthAmerican 4 inch squareelectric box,NorthAmeri- SIGA-AB4G-LF: Default=Fire can 4 x 4 inch octagonal concrete ring(mud box),and standard VolumeSetting Cut/remove jumper for Default=High Fire plus CO European 100 mm squareelectric boxes.The terminal blockmakes Cut/remove field wire connections fast and efficient.After wiring,a simple push jumper for SI GA-AB 4G: low dB ® ® ToneSetting and twist motion locksthe Signature detector into the base. Default=Temporal DATA-DATA-DATA+ Cc+Ce- OUT Ila Iwa,T Cut/remove jumper for SIGA-AB4GT(-LF) SIGA-AB4G II II II II II Steady /—\ 1 �j j'j I 1 o SIGA-AB4GT: O 1411,01610101 Not Used 24 Vdc in 111111 - 24Vdcout \� - From powersupply •al BO or previous base + E-E' + Tonext base or EOL relay -Data in _ Data out lila _ to next Signature device -. FromSignatureController 1(elAI ' or previous device + + ��iII11111111111 �r ..;,:i. .____1..„.1_,. 1 1 fiN � Base Plate I Base Plate Typical Wiring, Fire-plus-COmode —'� AB4GT, AB4G-LF sounder bases I!` Trim Ring ��I✓ Fire-plus-COmode TrimRing wiring for detector 'Nil • operationof bases ®. : ill Ilii, 11111 III SIGH-RM1 AUX_RISER+ �' RisMMuetior ORAUX_RISER- Module 24 VDC 1 xr P,,Nr Porn listed a TCDR Data Power .� 1_, © n out 0 P2 ,----, O O Data SLC+ Surf ace Mounting In SLC - AB4G-SB:When using the Fire-plus-COmode wiring (. ,, AB4G-SBsurface mount box, for detector and system 'NM0 Imo' L L.L install a reinforcing plate at every operationof bases �. • knockout.(Reinforcing plates are 3, included with the box.)Remove the knockoutfirst,and then slide on rip �' .�. '� the reinforcing plate into the plas- II'�;IIIJ AB4G-SB tic housing.After the plate is in ii 111 i l isersiGMo M1 nux_RIs:,1 RiserMonitior place,install a conduit connector A° R15ER o 0 o O Module Optional Surface Box X24voC � and nut(not supplied). from listed (6.8"diameterx 1.8" deep) powersupply ® co Data P,9 a u,4 out o o o J 1 zl CO- Page Data In sic- Page 3 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 Typical Wiring, Fire mode AB4G,AB4G-LF sounder bases First device Last device Detector operates the base /® ° ° ®\ /® 0 0 ®\ The base follows the state of the detector, going into and out of ° o o alarm with the detector.The Signature CR module is optional,and Fac - � is used to silence the bases on the line. - ° III I_(hl�_ a III 1_0_1_ o 24 Vdc Y■•'——- rte■ Listed EOL From listed + / rsey and power supply 'I"•" 1/ supervising /7 module 0 0 O CR 0 0 Data in + ® i From Signature controller System turns on all bases First device Last device /® 0 0 ®\ /® 0 0 ®\ All bases on the line can be activated by system programmingthat triggers the Signature CR R to reverse the supplied polarity.The oo Signature CR module is optional,and is used to silence the bases ° ° on the line. ° il I III III a IIS iLill el>lTlst ls7>>jP soleDIMIst>jsi> 24 Vdc YIYY Iilimi1 From listed + — — • / Listed EOL power supply relay and IMI I poem // supervising O 0 0 0 0 0 7/ module CR CRR O o O O Ipum 'i ICi emolI Data in + From - Signature controller System turns on bases with synchronization First device Last device All bases on the line are activated by system programmingthat triggers the Signature CR R module.The tempo raloutput is syn- 0 5 0 chronizedby the G1M-RM. If the Signature CRR module is not 6 a .e a m activated,each detectorcan still operateits base,but the bases " " CO o will not be synchronized.The Signature CR module is optional, __JI—I I� II_III o III�III_III_I� [ 0140ls�+l -1-> 01014-1)141:10tand is used to silence the bases on the line. `-- ilk ■ Listed EOL relay and / supervising ¶—I 1/ module I I IU III U II aa, Ilo ml O 0 0 O 0 O 0 0 0 G1M-RM CR CRR O 0 0 0 0 0 Ui� 1S1 a!l imi1 ,I@romn71 24 Vdc From listed + power supply Data in + From - Signature controller Page 4 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 Sound LevelOutput, AB4G-LF Sound LevelOutput, AB4G Signal Low dBA High dBA1 Signal Voltage Low dBA High dBA Nominal Sound Level2 Reverberant room per UL 464* Steady/T3/T4 83 87 16 Vdc 71.5 78.1 Temporal 24 Vdc 75.5 80.7 33 Vdc 78.5 83.1 Per UL 268,UL 521, UL 2075(reverberant)3 16 Vdc 75.5 81.7 TC3(fire pattern) 76.3 80.8 Steady 24 Vdc 79.5 84.5 TC4(CO pattern) 73.0 77.4 33 Vdc 81.8 86.5 Steady 80.9 85.3 Reverberant room per UL 268 111.- JIM 16 Vdc 77.5 84.1 Per UL 464(reverberant)3 Temporal 24 Vdc 81.5 86.7 TC3(fire pattern) 70.3 74.8 33 Vdc 84.5 89.1 TC4(CO pattern) 67.0 71.4 16 Vdc 81.5 87.7 Steady 74.9 79.3 Steady 24 Vdc 85.5 90.5 1 For NFPA 72 and NFPA 720 applications,the high dBAsettings can be used for 33 Vdc 87.8 92.5 public mode evacuation. dB A=Decibels,A-weighted 2 Anechoic chamber@ 10ft "ForUL 464 applications low dBAsettings arefor privatemode only. 3 As measured in a UL reverberant room at 10 ft OperatingCurrent(RMS), AB4G OperatingCurrent,AB4G-LF Voltage Low dBA High dBA Notes mA RMS UL/ULCratings 16 VDC 17 28 VDC=Volts direct 24 VDC 24 41 current,regulatedand Low dBA High dBA 33 VDC 31 52 filtered Signal 16 V DC 24 V DC 33 V DC 16 V DC 24 V DC 33 V DC 16 VFWR 41 48 TC3 76.0 76.4 85.6 92.0 76.0 93.6 24 VFWR 51 60 VFWR=Volts full wave TC4 112.8 148.0 125.6 107.2 150.0 150.8 33 VFWR 60 66 rectified Steady 75.2 76.0 92.4 143.0 92.0 97.0 Sound Level Output, AB4GT Operatingcurrent(RMS), AB4GT Signal Voltage Low dBA High dBA Low dBA High dBA 31 mA 52 mA Reverberant room per UL 4641 TC3(fire pattern) 16 VDC 80.5 85.2 TC4(CO pattern) 16 VDC 73.9 77.5 Reverberant room per UL 268 and FM 2 TC3(fire pattern) 16 VDC 86.5 90.8 TC4(CO pattern) 16 VDC 77.5 84.1 Sound pressure level per CAN/ULC-S525 3 Temporal 24 VDC 95 91 Steady 24 VDC 93 89 1 For UL 464 applications,low dB Asettings are for privatemode only. 2 For UL 268 applications,the high setting must be used forevacuation. 3 Voltageis regulatedand filtered. Page 5 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 Specifications \CbWARDS SIGA-AB4G I SIGA-AB4GT I SIGA-AB4G-LF �• °^"°"'°°"^°' °^ Riseroperatingvoltage 16 to 33 VDC OperatingCurrent See tables on previouspage LIFE SAFETY&INCIDENT MANAGEMENT Supervisory Current DC=1.46 mA, FWR=2.15 mA DC=1.46 mA DC=6.0 mA Contact us... DefaultOutput Volume High dB Email: edwards.fire@fs.utc.com DefaultTone Temporal Fire:Steady or TC3; Web: Edwards-fire.com Fire-plus-CO:TC3or TC4 Resonant frequency 3.2 kHz 520 Hz+/-10% EDWARDS is a UTC brand. Temporal pattern 0.5 son,0.5 s off, As determined by the SIGA-TCDR... 1016 Corporate Park Drive Mebane,NC 27302 0.5 son,0.5 S off, Fire:Steady or TC3; 0.5 son,1.5 s off, Fire-plus-CO:TC3 or TC4 ©2016 United Technologies Corporation. repeatcycle All rights reserved. Compatible detectors All Signature Series detectors Compatible electrical boxes AB 4G-SBsurface box foraudible base;4 in.square by 2-1/8 in.(54 mm)deep box;3-1/2 in.octagonal by 2-1/8 in.(54 mm) deep box;Standard Euro pean100 mm2 box Wire size 12 to 18 AWG(0.75 to 2.50 mm2) B asediameter _ 6.8 in.(173 mm) B aseheight fro mbox 0.8 in.(21 mm) 1.4 in. (35 mm) Maximum distance fromceiling Wall mount- 12 in.(305 mm) Environmenttype Indoor only 0 peratingenviro nment Temperature 32 to 120°F (0 to 49°C) Relativehumidity 0 to 93%noncondensing Storage temperature -4 to 140°F(-20 to 60°C) Listings UL,ULC,CSFM UL,CSFM Orderinglnformation Catalog Description ShipWt.,lb.(kg) Number SIGA-AB4G-LF Low Frequency Sounder BaseforCO and Fire Detectors 0.3(0.15) SIGA-AB 4GT Sounder Basefor CO and Fire Detectors 0.3(0.15) SIGA-AB4G Sounder Basefor Fire Detectors 0.3(0.15) Related Equipment SIGA-TCDR Temporal Pattern Generator 0.2 (0.1) SIGA-MCRR Polarity Reversal Relay (Plug-in UIO module) 0.18 (0.08) SIGA-CRR Polarity Reversal Relay (Standard mount module) 0.2 (0.1) SIGA-MCR Control Relay Module (Plug-in UIO module) 0.18 (0.08) SIGA-CR Control Relay Module (Standard mount module) 0.2 (0.1) SIGA-RM1 Riser Monitor Module 0.2 (0.1) G1M-RM Signal Master (1-gang remote mount) 0.2 (0.1) AB 4G-SB Surface Boxfor Audible Base 1.0 (0.45) Page 6 of 6 DATA SHEET E85001-0640 Not to be used for installation purposes. Issue 1 EDWARDS°Catalog Intelligent Initiating Devices ¶ bWARDS c`United Technologies LIFE SAFETY 15. INCIDENT MANAGEMENT Intelligent Smoke Detector "7 Olt OWEN SIGH-PD �wA�os S853 FM Overview Standard Features The Signature Series SIGA-PD optical smoke detector brings Note:Some features described here may not be supported by advanced sensing tech nologyto a practical design that increases all control systems.Check your control panel's Installation and efficiency, saves installation time,cuts costs,and extends Operation Guide for details. life safety and property protection capabilities. Continuous • Next Generation Optical Smoke Sensing Technology self-diagnostics ensure reliability over the long-haul,while environmental compensation helpsreduce maintenance costs. • Wide 0.53 to 3.94%/ft. (1.7 to 12.35 %/m)smoke obscuration Like all Signature Series detectors,the SIGA-PD is an intelligent • Uses Existing Wiring device that gathers analog information from its optical sensor, • Automatic Device Mapping converting this data into digital signals.To make an alarm decision, pp g the detector's on-board microprocessor measures and analyzes • Up To 250 Total Signature Addresses Per Loop sensor readings and compares this information to historical data. • Two Levels of Environmental Compensation Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. • Two Levels of Dirty Detector Warning • Twenty Pre-Alarm Settings • Five Sensitivity Settings • Non-Volatile Memory • Electronic Addressing • Identification of Dirty or Defective Detectors • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status Led • Standard, Relay, Fault Isolator, and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Page 1 of 4 DATA SHEET E85001-0646 Not to be used for installation purposes. Issue 1.2 Application Testing & Maintenance TheSIGA-PD detects extremely small particles of combustion Each detector automatically identifies when it is dirty or defective and triggers an alarm at the first sign of smoke.Thanks to its and causes a"dirty detector"message.The detector's sensitivity high-performance forward-scattering reflective response measurement can also be transmitted to the loop controller. technology,the photoelectric smoke sensor responds quickly A sensitivity report may be printed to satisfy NFPA sensitivity and reliably to a wide range of fire types,especially slow measurements,which must be conducted at the end of the first burning fires fuelled by combustibles typically found in modern year and every two years thereafter. multi-use buildings. The user-friendly maintenance program sh owsthe current state of each detector and otherpertinent messages. Single detectors Compatibility may be turned off temporarily from the control panel.Availability of maintenance features is dependent on the fire alarm system used. TheSIGA-PD detector is compatible only with the Signature LoopController. Accessories Installation Detector mounting bases havewiring terminals that are accessible from the"room-side"after mounting the base to the Signature Series detectors mount t, _ electrical box.The bases mount to North American 1-gang boxes t tr � to North American 1-gang boxes, -�� �.r' ) and to 31/2 inch or 4 inch octagon boxes,11/2 inches(38 mm) 3-1/2 inch or 4 inch octagon "' deep.They also mount to European BESA and 1-gang boxes with boxes,and to 4 inch square Self-locking tab 60.3 mm fixing centers.TheSIGA-SB4,SIGA-RB4, and SIGA-IB4 electrical boxes 1-1/2 inches mount to North American 4 inch sq. electrical boxes in addition to (38 mm)deep.They mount to the above boxes.They include the SIGA-TS4 Trim Skirt,which is European BESA and 1-gangused to cover the"mounting ears"on the base.TheSIGA-AB4G boxes with 60.3 mm fixing v„•”-_yam,.,, LED Indicator mounts to a 4 inch square box only. centers. See mounting base << �� installation and wiring for31101. , � ti I more information. (/ lk� Sensing and reporting technology SIGA-AB4G/T/LF SIGA-SB SIGH-IB SIGH-RB SIGH-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Themicroprocessor in each detector provides additional benefits—Self-diagnostics and History Log,Automatic Device Remote LED SIGA-LED-The remote LED connects to the Mapping,and Fast,Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North Self-diagnostics and History Log Each Signature Series American size 1-gang plastic faceplate with a wh itefinish and detector constantly runs self-checks to provide important red alarm LED. maintenance information.The results of the self-check are SIGA-TS4 Trim Skirt-Supplied with 4 inch bases,it can also automatically updated and permanently stored in the detector's be ordered separately to use with the oth erbases to h elph ide non-volatile memory surface imperfections not covered by the smaller bases. Automatic Device Mapping-The loop controller learns where Sounder Bases-Signature Series sounder bases are designed each device's serial number address is installed relative to other for use where localized or group alarm signaling is required. devices on the circuit.Themapping feature provides supervision of each device's installed location to prevent a detector from being • SIGA-AB4G bases provide sounder capability to Signature reinstalled(after cleaning etc.)in a different location from where it Series to heat and smoke detectors.They are not intended was originally. for use with combination carbon monoxide detectors in Fire-plus-COmode. Fast Stable Communication On board intelligence means • SIGA-AB4GT bases provide sounder capability to Signature less information needs to be sent between the detector and the Series smoke and heat detectors, as well as carbon loop controller. Otherthan regular supervisory polling response, monoxide detectors when used with a SIGA-TCDR Temporal the detector only needs to communicate with the loopcontroller Pattern Generator. when it has so meth ingnew to report. • SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and h eat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator.Th e SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page2of4 DATA SHEET E85001-0646 Not to be used for installation purposes. Issue 1.2 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2), #16 Audible Sounder Bases,Fire Mode (1.0mm2), #14 AWG(1.5mm2), and#12 AWG(2.5mm2)wire sizes. AB4GT,AB4G,AB4G-LF sounder bases Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. Standard Detector Base,SIGA-SB,SIGA-SB4 SIGA-AB4GT, 00 SIGALF: SIGA-AB 4G, ®jumper cuts® Outputut Mode This is the basic mounting SIGA-AB4G-LF: Default=Fire base for EDWARDS Signature Remote LED Volume Setting forCuFir plusove jumper g Default=High for Fire plus CO Series detectors.The SIGA- 1 Max resistance Cut/remove LED Remote LED is supported 40' per wire jumper for SIGA-AB4G: + must not exceed low dB ® ® Tone Setting 10 Ohms Default=Temporal by th IS Base. DATA-DATA-DATA+ 6 SIG+ SIG- OUT IN IWOUT Cut/remove jumper Term Description �� - \ I I I I I I I1I I1I o for Steady 1 Not Used /l ,..-11- L-.i.-.i.-.i.-.i 2 DATA IN/OUT(+) 1••• •••,t••• •••1•••1 SIGA-AB4GT: O 3 Not Used e r-7'` Ig+1Ig+I�+�I4+1Ig+kI Not Used 4 DATA IN(-) DATA IN(-) a DATA OUT 1-) ,m,m"n" lI'-`1 4 Remote LED(-) I 111111 5 Remote LED(+) 6 Not Used DATA OUT(+I 24 Vdc in DATA IN(+) ■MM - To Vdc out 7 DATA OUT(-) From Signature Controller To Next Device From power supply g or previous base + M. + To next base or EOL relay or Previous Device - Data in _ Data out Isolator Detector Base,SIGA-IB,SIGA-1B4 From Signature Controller + + to next Signature device or previous device This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: • Th isdetector does not operate with o utelectrical power. - a short on the line causes all - As fires frequently cause power interruption, discuss 6, isolators to open with in23 msec o -y% 0 further safeguards with the local fire protection specialist. -at 10 msec intervals,beginning / aa, • Th isdetector does not sense fires in areas where smoke o n one side of the Class A cannot reach the detector. Smoke from fires in walls, circuit nearest the loop DATA IN(-) \ �r z ' roofs, or on the opposite side of closed doors maynot controller,the isolators DATA OUT(-) pp close to provide the reach the detector. next isolator down DATA IN(+) DATA OUT(+) • Photoelectric detectors h avea wide range of fire-sensing From Signature Controller To Next Device the line with power or Previous Device capabilities and ares best suited for detecting slow, -when theisolatornext Term Description smoldering fires. 1 Not Used to the short closes,it 2 DATA IN/OUT(+) • In Canada,install accordingto CAN/ULC-S524 Standard for reopens within 10 msec. 3 Not Used) the Installation of Fire Alarm Systems, CSA C22.1 Canadian DATA IN Theprocess repeats beginning on 5 Not Used p g g 6 DATA OUT(-) Electrical Code,and the local authority havingjurisdiction. the otherside of the loop controller. 7 Not Used Relay Detector Base,SIGA-RB,SIGA-R B4 This base includes a relay. Normally-Normally- Common Closed Open Normally Open or Normally Closed operation is selected during installation.The dry contact is rated forl amp 0t.6 ,r .,A (pilot duty)@ 30 Vdc.The a-% ir relay's position is supervised -9` Il to avoid accidentally jarring it DATA IN(-) ( =L I � DATA OUT(-) out of position.The SIGA-RB can be operated as a control DATA IN(+) DATA OUT(+) From Signature Controller To Next Device relay if programmed to do so or Previous Device Term Description at the control panel.The relay 1 Normally Open base does not support the CONTACT RATING 2 DATA IN/OUT(+) SIGA-LED Remote LED. 1.0 (Pilot u 3 DAMN( oQDutyy)) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT(-) Page 3 of 4 DATA SHEET E85001-0646 Not to be used for installation purposes. Issue 1.2 c Dimensions `D`A, Y YAR DS _ 04299 wn.anmeio9ies /l LIFE SAFETY&INCIDENT MANAGEMENT �� ,``` CD Contact us... 1995 0_11 2316 fri�III� O Email: edwards.fire®fs.ufc.com �rca�woa Web: edwards-fire.com 411 ELMII';I % / 1016 Corporate Park Drive 4.,9s Mebane,NC 27302 EDWARDS is a registered mark in the United States and oth ercountries. 23954 ©2018 United Technologies Corporation. All rightsreserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 51 pA Alarm current 68 pA Smoke Sensitivity Range UL/ULC:0.53 to 3.94%/ft.(1.7 to 12.35 %/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 120°F (0 to 49°C),0 to 93%RH,noncondensing Construction _ High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529,UL 268,268A,CSFM,FM approved Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-PD Intelligent Optical Smoke Detector 0.4(0.16) Accessories 11110 SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-R B4 4-inch Detector Mounting Base w/Relay,c/w Trim Skirt 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) SIGA-AB4G Audible(Sounder)Base for Fire Detectors 0.3(0.15) SIGA-AB4G-LF Low Frequency Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-AB4GT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page 4 of 4 DATA SHEET E85001-0646 Not to be used for installation purposes. Issue 1.2 EDWARDS°Catalog ► Intelligent Initiating Devices E wA R s ' 0 United Technologies LIFE SAFETY 15. INCIDENT MANAGEMENT 4°111.111111111.11711"1116--- _7%4%4\ Intelligent Multisensor Smokelet Timm Nokia!, 81114.4 and CO Detector �, SIGA-PCDI�n S853 FM Overview Standard Features The Signature Series SIGA-PCD detector b ringsadvanced Note:Some features described here may not be supported by multisensor technology to a practical design that increases all control systems.Check your control panel's Installation and efficiency, saves installation time,cuts costs,and extends Operation Guide for details. life safety and property protection capabilities. Continuous • Next Generation Detection Technology self-diagnostics ensures reliability over the long-haul,while environmental compensation helps reduce maintenance costs. • Integrates optical smoke with carbon monoxide detection The SIGA-PCD provides a comb inatiorbf optical detection for • Wide 0.53 to 3.94%/ft. (1.7 to 12.35 %/m)smoke obscuration the early detection of smoke,with the added element of carb on • Sensor Markings Provide Easy Testing Identification monoxide sensing.The result is a detector that pulls doub leduty: continually monitoring the environment for signs of fire— as well • Uses existing wiring as its invisib leyet deadly companion:carbon monoxide. • Automatic device mapping Like all Signature Series detectors,the SIGA-PCD gathers analog • Ground fault detection b ymodule information from its sensing elements and converts this data into digital signals.To make an alarm decision,the detector's on-b oard • Up To 250 Total Signature Addresses Per Loop microprocessor measures and analyzes smoke sensor readings • Two levels of environmental compensation and compares this information to historical data.Digital filters remove signal patterns that are not typical of fires,thus virtually • Two levels of dirty detector warning eliminating unwanted alarms.The detector also analyzes the • Twenty pre-alarm settings smoke sensor independently from the CO sensor to determine • Five sensitivity settings whether to initiate a fire alarm, a life safety CO alarm, or b oth. • Non-volatile memory • Electronic addressing • Environmental compensation • Automatic day/night sensitivity adjustment • Bicolor(green/red)status LED • Standard, relay,fault isolator, and audib lemounting bases Page 1 of 4 DATA SHEET E85001-0651 Not to be used for installation purposes. Issue 1.2 Application Sensing and reporting technology Smoke detection The microprocessor in each detector provides additional The SIGA-PCD detects extremely small particles of comb ustion benefits—Self-diagnostics and History Log,Automatic and triggers an alarm at the first sign of smoke.Thanks to Device Mapping,and Fast, Stab leCommunication. its high-performance forward-scattering reflective response Self-diagnostics and History Log-Each Signature Series technology,the photoelectric smoke sensor responds quickly detector constantly runs self-checks to provide important and reliably to a wide range of fire types,especially slow maintenance information.The results of the self-check are b urningfires fuelled b ycomb ustib leAypically found in modern automatically updated and permanently stored in the detector's multi-use b uildings. non-volatile memory. CO Detection Automatic Device Mapping-The loopcontroller learns where Monitored CO detection,such as that provided by the SIGA-PCD, each device's serial numb eraddress is installed relative to other is becoming mandated with increasing frequency in all types of devices on the circuit.The mapping feature provides supervision commercial applications, b utparticularly in occupancies such as of each device's installed location to prevent a detectorfrom b eing hotels,rooming houses,dormitories,day care facilities,schools, reinstalled(aftercleaning etc.)in a different location from where hospitals,assisted living facilities,and nursing homes.Known as the it was originally. "Silent Killer,"CO is odorless,tasteless,and colorless. It claims nearly 500 lives,and results in more than 15,000 hospital visits annually. Fast Stable Communication-On-board intelligence means less information needs to b esent between the detector and the loop controller. Other than regular supervisory polling response, Compatibility the detector only needs to communicate with the loop controller The SIGA-PCD detector is compatible only with the Signature when it has something new to report. LoopController. Accessories Installation Detector mounting bases have wiring terminals that are Signature Series detectors mount accessible from the"room-side"after mounting the b aseto the electto North American 1-gang b oxes, and to 31/2b inch oe4 inch octagon b o�es rthAmenchesl(38 ngmj oxes 3-1/2 inch or 4 inch octagon deep.Theyalso mount to European BESA and 1-gang b oxeswith b oxes,and to 4 inch square Self-lockingtab p g 9 electrical b oxesl 1/2 inches 60.3 mm fixing centers.The SIGA-SB4,SIGA-RB4, and SIGA-IB4 mount to North American 4 inch sq. electrical b oxesin addition to (38 mm)deep.They mount to the above b oxesThey include the SIGA-TS4 Trim Skirt,which is European BESA and 1-gang used to cover the"mounting ears"on the b ase.Sounder b ases bth 60.3 mm fixing LED Indicator mount to a 4 inch square b oxesonly. centers. See mounting b ase installation and wiring for more / , =+ information. a y // C �'' ) AI 6. • Testing & Maintenance SIGA-AB4G/T/LF SIGH-SB SIGH-IB SIGH-RB SIGH-L ED Scheduled maintenance(regular or selected)for proper detector Audible Base Standard Base Isolator Base Relay Base Remote LED operation should b eplanned to meet the requirements of the Authority Having Jurisdiction(AHJ). Refer to current NFPA 72, Remote L EDSIGA-LED-The remote LED connects to the NFPA 720, and ULC CAN/ULC 536 standards. SIGA-SB or SIGA-SB4 Standard Base only. It features a North Smoke Sensor Sensitivity American size 1-gang plastic faceplate with a white finish and The SIGA-PCD determines when its optical sensor is dirty or red alarm LED. defective and can transmit sensitivity data to the loop controller. SIGA-TS4 Trim Skirt-Supplied with 4 inch b ases,it can also A sensitivity report can also b eprinted to satisfy NFPA sensitivity b eordered separately to use with the other bases to help hide measurements which must b econducted at the end of the first surface imperfections not covered b ythe smaller b ases. year and every two years thereafter.The availability of maintenance features depends on the fire alarm system used. Sounder Bases-Signature Series sounder b asesare designed for use where localized or group alarm signaling is required. CO Sensor Life The CO sensor has a 10-year life from the date of manufacture or • SIGA-AB4GT b asesprovide sounder capability to the when the control panel indicates a sensor end-of-life condition, SIGA-PCD when used with a SIGA-TCDR Temporal Pattern whichever comes first.When the sensor reaches its end of life,the Generator to separate CO(TC4)and Fire(TC3)tone patterns. detector signals a"COMMON TRBL ACT"condition on the control • SIGA-AB4G-LF bases provide 520 Hz low frequency panel. Pressing the Details b uttonon the control panel displays sounder capability to the SIGA-PCD when used with a SIGA- "END OF LIFE ACT" providing verification that it is an end-of-life TCDR Temporal Pattern Generator to separate CO(TC4)and trouble of the CO sensor.This trouble remains active until the Fire(TC3)tone patterns.The SIGA-AB4G-LF is suitab lefor detector is replaced, even if the panel is reset. applications requiring low frequency audib letones. Page 2 of 4 DATA SHEET E85001-0651 Not to be used for installation purposes. Issue 1.2 Typical Wiring Audible Sounder Bases,Fire Mode The detector mounting bases accept#18 AWG(0.75mm2), #16 AB4GT,AB4G,AB4G-LF sounder bases (1.0mm2), #14 AWG(1.5mm2), and#12 AWG(2.5mm2)wire sizes. Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred Thl for ease of installation. SIGA-AB4GT, SIGA-AB4G-LF: SIGA-AB4G, ®Jumo p per cuts® Output Mode p SIGA-AB4G-LF: Default=Fire Standard Detector Base,SIGA-SB,SIGA-SB4 Volume Setting Cut/remove jumper Default=High for Fire plus CO This is the b asicmounting Remote LED Cut/remove jumper for SIGA-AB4G: b asefor EDWARDS Signature ' Max resistance low dB ® ® Tone Setting Series detectors.The SIGA LED .1.11, per wire Default=Temporal must not exceed DATA-DATA-DATA+ + SIG+ SIG- OUT IN IN/OUT Cut/remove jumper Remote LED is supported by 10 Ohms for steady this Base. / ��T �j���j�-.�1�_.�I�-.@ o Term Description 4 r \ I% I I,%SI I'// I SIGA-AB4GT: 1 Not Used pJ I'll" rrIli+�lyl+�lr+�l�+�l Not Used 2 DATA IN/OUT(+) '• I 1111 1FI 4 DAt UsedTAIN( � I-9�� Mi� 4 DATA IN(-) 4 Remote LED(-) DATA IN(-I O z I O DATA OUT(-I 24 Vdc in - 5 Remote LED(+) From power supply ■-■1 - 24 Vdc out 6 Not Used or previous base + .,I + To next base or EOL relay 7 DATA OUT(-) DATA IN 1+1 DATA OUT(+1 From Signature Controller To Next Device or Previous Device Data out Data in _ From Signature Controller + + to next Signature device or previous device Isolator Detector Base,SIGA-IB,SIGA-1B4 This b aseincludes a b uilt-in line fault isolator for use on Class A Audible Sounder Bases,Fire-plus-CO Mode circuits.A detector must b einstalled for it to operate.The isolator b asedoes not support the SIGA-LED Remote LED. AB4GT and AB4G-LF sounder bases only. The isolator operates as follows: These configurations require a SIGA-TCDR Temporal Pattern -a short on the line causes allGenerator to separate CO(TC4)and Fire(TC3)tone patterns. isolators to open within 23 msec 1,00...% ,y� -at 10 msec intervals,b eginning co Fire-plus-CO mode g g `;a wiring for detector °= ° on one side of the Class A �` operation of bases circuit nearest the loop /n�r— controller,the isolators DATA IN(-) \ `- z� DATA OUT(-) close to provide the next isolator down DATA IN(+) DATA OUT(+) �1���II 11����I the line with power From Signature Controller To Next Device ��I 111 ■ or Previous Device iiii iII� sIGA-RM1 -when the isolatornext AUX_RISER+ �' Riser Monitior to the short closes,it Term Description AUX_RISER- Module 1 Not Used O (f O reopens within 10 msec. 2 DATA IN/OUT(+) 24VDC e r s 5 3 DATA IN(-) from listed TCDR Data The process repeats b eginningon 4 Not Used power supply © Out 5 Not Used the other side of the loop controller. 6 DATA OUT(-) 4°2 P 7 Not Used c,` 0, Data sic+ I In sic- Relay Detector Base,SIGA-RB,SIGA-R B4 This b aseincludes a relay. Normally-Normally- Common Closed Open Fire-plus-CO mode wiring Normally Open or Normally for detector and system 'Nide Il Closed operation is selected operation of bases during installation.The dry g_ g_ contact is rated fort amp s�„i \ 'sa a'a (pilot duty)@ 30 Vdc.The � 1111111 1111111 relay's position is supervised J "--1i1 lii�i to avoid accidentally jarring it DATA IN(-) \ �k-z / DATA OUT(-) seGA-RM1 Aux_RissR• IIIIIikiirm Riser Monitior out of position.The SIGA-RB Dx R�GeR- i g Module can b eoperated as a control DATA IN(+) DATAOUT(+) A 24VDC O�III3 O O�ITl9 O eoperated Next Device From Signature Controller from listed TCDR CRR relay if programmed to do so or Previous Device power supply © Oo Data Term Description Out at the control panel.The relay 1 Normally Open 4 R9 9,9 b asedoes not support the CONTACT RATING 2 DATA IN/OUT(+) O O 1.0 Amp @ 30 VDC 3 Common Data suc+ 11 1 SIGA-LED Remote LED. (Pilot Duty) 4 DATA IN(-) In s«- 15 Not Used 6 Normally-Closed 7 DATA OUT(-) Page 3 of 4 DATA SHEET E85001-0651 Not to be used for installation purposes. Issue 1.2 � `A, c Dimensions �YYAR DS 04299 LIFE SAFETY&INCIDENT MANAGEMENT 7. �� `,` 996 ._..7\ Ill Contact us... :C7— I L 2316 itt O Email: edwards.fire@fs.utc.comg) Jrca�woa Web: edwards-fire.com e . �IMr Ihl 7--1016 Corporate Park Drive _ 4.,99 Meb ane,NC 27302 EDWARDS is a registered mark in the United States and other countries. 03954 ©2018 United Technologies Corporation. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 51 pA Alarm current 68 pA Smoke Sensitivity Range UL/ULC:0.53 to 3.94%/ft.(1.7 to 12.35 %/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Wall mounting 12 in.(305 mm)max.from ceiling Compatib Id7 ases See Ordering Information Compatib ledetector testers Testifire 1000,Testifire 2000 Operating environment 32 to 120°F (0 to 49°C),0 to 90%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic UL CO alarm level 70 ppm 60 to 240 minutes per UL 2034,CAN/CSA 6.19 150 ppm 10 to 50 minutes; 400 ppm 4 to 15 minutes UL CO false alarm level 30 ppm 30 days per UL 2034,CAN/CSA 6.19 70 ppm 60 minutes Agency Listings, UL 268, UL 2075. SIGA-PCD Evaluated to the CO alarm sensitivity limits of UL 2034. Agency Listings, ULC Listed to CAN/ULC-S529 and CAN/CSA 6.19. SIGA-PCD-CA CSFM,FM approved. Warnings & Cautions • This detector does not sense Ordering Information fires in areas where smoke Catalog Description Ship Wt. cannot reach the detector. Number lbs(kg) Smoke from fires in walls, SIGA-PCD Multisensor Smoke and CO Detector 0.4(0.16) roofs, or on the opposite side SIGA-PCD-CA Multisensor Smoke and CO Detector,Canadian Market 0.4(0.16) of closed doors may not reach the detector. Compatible Bases • Photoelectric detectors have SIGA-SB Detector Mounting Base-Standard a wide range of sensing SIGA-SB4 4-inch Detector Mounting Base c/wTrim Skirt Capabilities, and are b est SIGA-RB Detector Mounting Base w/Relay suited for detecting slow, SIGA-RB4 4-inch Detector Mounting Base w/Relay,c/w Trim Skirt 0.2(.09) smoldering fires. SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt • Install per NFPA 72 National SIGA-LED Remote Alarm LED(not for EN54 applications) Fire Alarm and Signaling Code, SIGA-AB4G-LF Low Frequency Audib le(Sounder)Base for CO and Fire Detectors 0.3(0.15) NFPA 720 Standard for the SIGA-AB4GT Audib le(Sounder)Base for CO and Fire Detectors 0.3(0.15) Installation of Carbon Monoxide SIGA-TCDR Tone Generator for Detector Sounder Bases with CO mode 0.2(0.1) (CO)Detection and Warning SIGA-TS4 Trim Skirt(supplied with 4-inch b ases) 0.1 (.04) Equipment, and UL 2075 SIGA-RTA Detector Removal Tool Standard for Gas and Vapor SIGA-VA Detector Cleaning Tool Detectors and Sensors. 0 N Page 4 of 4 DATA SHEET E85001-0651 Not to be used for installation purposes. Issue 1.2 EDWARDS®Catalog►EST3 Life Safety Platform bWARDB 0.United Technologies LIFE SAFETY &. INCIDENT MANAGEMENT I .. Signature Driver • = �. � � ? : . � Controller Modules n .!! 3-SSDC1, 3-SDDC1, 3-SDC1 , '' :.. . , _ :`. :i who ® 7165-1657: 0186/0306 1.415 CE 53000 ® FDNY APPROVED EN 54-2:1997+Al:2006 EN 54-4:1997+Al:2002+A2:2006 EN 54-16:2008 Overview Standard Features The 3-SSDC1 and 3-SDDC1 Signature Driver Controller modules • One or two circuit versions providean intelligent interface betweenthe 3-CPU 3 module and • Dedicated microprocessor control Signature Series devices.Each module contains its own micro- processor used to coordinate,processand interpret information • Full digital communication received fromand sent to Signature devices.Powerand commu- • Specializedcommunication protocol nications is received directlyfromthe controlpanel rail assembly. -Less sensitiveto cable characteristics The 3-SSDC1 Single Signature Driver Controller module supports -Utilize existing wiring in most applications one Signature Data circuit,while the 3-SDDC1 Signature Dual Driver Controller module sup portstwo Signature circuits.Both • Loopalarm in under 750 milliseconds modules occupy one rail space in the fire alarm controlcab met • Device location supervision and provideremovable field wiring terminalsto aid installation. -Unexpectedadditional device addresses Innovativedesign gives the 3-SSDC1/3-SDDC1 and Signature -Missing device addresses devices truly"distributed intelligence".Signaturedetectorsand -Switched device locations modules have their own on-board microprocessor communicating -Programmeddevice parameters with the loopcontroller in a fully digital communication format.This • Automaticnonvolatileas-built mapping increases the accuracy of the information coming to and fro mthe -Stores"actual"and"expected"device data loopcontroller by reducingthe effects of capacitance and noise. -Storesphysicalconnection sequence including `T"taps With decentralized intelligence much ofthe decision making moves • Automaticday/night sensitivity fromthe loopcontroller to the devices.Advanced fire detection • algorithms processed withinthe Signature devices effectively end Supportsup to 250 intelligent Signaturedetectors unwanted alarms. Environmental compensation and multiple sens and 250 Intelligent Signature Modules ing element decision making operations are resident in the devices. • Up to five 3-SDDC1s per node Intelligent devices allow the Signature Controllers to execute commu- -Total of 10 Signature circuits nication and system functions with greatersp eedand low baudrates, ▪ Removablefield wiring terminal blocks increasing the accuracy of information transmitted between the loop controller and devices. • Multiple survival modes — stand alone • Fully backward compatible with 3-SSDC and 3-SDDC • Supportsthe full line of Signature II devices,including carbon monixide detection Page 1 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 Application U pto 125 detectors and 125 modules are supported overa single During installationa common problemwith analog/addressable pairof wires by the 3-SDC1 Signature Cardsthat plug into the systems is locating ground faults.The 3-SSDC1 and 3-SDDC1 Signature controller modules.Loopdistances over11,000 feet controllers have the ability to locate ground faults by specific mod- (3300m)are possible.Class B wiring,ClassA and ClassX wiring ule, speeding up the troubleshooting processAnothersignificant are supported. advantage of the 3-SSDC1/3-SDDC1 controllers during com- The 3-SSDC1 and 3-SDDC1 use advanced communication missioning is electronic addressing and mapping.This eliminates formatsthat provideexceptional response.Using a"BROADCAST duplicate addresses,which are also very difficult formost systems PO LL"the loopcontroller checks the entire device circuitforany to locate. changes of state.Should one or more devices reporta change the During maintenance,should groups of detectorheads be removed 3-SSDC1/3-SDDC1 uses"DIRECTADDRESS SEARCH"to find forserviceand returned into the wrongsmoke detectorbase reportingdevice(s).Devicesthat have entered the alarm state or (location),the 3-SSDC1/3-SDDC1 will automatically detect the become active are located nearly instantaneously. problem.If the attributes of the switched devices are the same, The unique use of"BROADCAST PO LLING"combined with"DI- the system will automatically download the correct soft addresses RECTADDRESS SEARCH"ensuresthat only new informations and algorithms to the devices(maintaining location supervision). transmittedallowing a reduced baud rate with fast respo nsetime. If the attributes are not the same the 3-SSDC1/3-SDDC1 will send The low baud rate is ideal for retrofit applications since in most a map fault indication to the 3-CPU 3 and post a trouble indicating applications existing wiring can be used. the specific devices in fault. To enhance survivability of the system the 3-SSDC1/3-SDDC1 The 3-SSDC1/3-SDDC1 also monitors the Signature Series sup portsa standalonemode for Signature devices.Two cata- devices for maintenance and trouble conditions.Each smoke de- stro p hicfailure modes are sup p o rted.lf the 3-CPU(1/3)fails, tectorcontains intelligence to adjust with environmental changes. the loopcontroller will continue to poll its devices.If an alarm This expandsthe amount of time requiredbetweencleaning while is detected it will be sent on the local rail communication bus maintaining a constantalarmthreshold.As the detectorbegins to and received by other local rail modules.A common alarm exhaust the environmental compensation,and reachesthe 80% condition throughout the panel will result.If the local rail mod- level,the 3-SSDC1/3-SDDC1 will indicate a maintenance alert ule(3-SSDC1/3-SDDC1)fails,and a device(smokeor module) or dirty condition to the 3-CPU and indicate the specific device detects an alarm,specializedcircuitry will make the node aware of requiring cleaning.If cleaning is not performed the detecto rwill the alarm condition.The 3-CPU(1/3)will communicate the alarm continue to operateuntil all of its environmental compensations condition to the rest of the network. Having multiple redundant utilized.At this point the 3-SSDC1/3-SDDC1 sends a dirty trouble modes is paramountin a life safety system. indication to the 3-CPU and posts a trouble condition. If mainte- Every time the 3-SSDC1/3-SDDC1 communicates with a detector Hance is still not performed the Signature detecto rwill auto mati fro a green LED on the detectorflashes.Normal green LED activity is cally removeitsen breaserviceonce the programmedthreshold not disturbing to building occupants,but can be quickly spotted window has been reached(preventing a false alarm). by a maintenancetechnician.A red LED on the detectorturns on When a detectorincludes carbonmonoxide(CO)detection,the only in the alarmcondition. detectormonitors its CO life remainingforthe CO sensorelement The 3 SSDC1/3 SDDC1 also supervises the device wiring,physi and providesthis informationautomatically to the panel.Formain- cal location of each device and the programmeddevice charas tenance of the system the CO life remaining is also available by teristics.This EDWARDS/Signature Series unique characteristic is simply running a maintenance rep o rtat the panel or through the accomplished by"MAPPING"the Signaturecircuitand committing Fireworks lly generated calinterfa thee. p unique CO maintenancesignaleis8see is the map to memory.Upon powerup the loopcontroller will scan automatically generated by panel when there is 8/o(several device serial numbers and map their physical location sequence months)of CO element life remaining.Should the CO senso rete on the loop, including"T"taps.After mapping is complete the ment not be replaced after the maintenancesignal is reported, an controller automatically addresses each detectorand module "End of Life"trouble automatically posts on the panel when the through downloading overthe loop.There are no switches or dials CO sensor detection capability is exhausted. to set. Each device is assigned a unique soft address generated Remote test capability permits devices to be put in alarm,pre- by the site specific program. alarm,supervisory, monitor,or security alarm,or trouble fro mthe The 3-SSDC1/3-SDDC1 then comparesthe"Actual"physical panel menu or controls.This facilitates testing of smoke and heat device data to the"Expected"site specific programdata.If any detectorsas well as monitor and securitydevices.Fast test is also correlations are different,the loopcontroller issues a trouble to the pro.videdforCO detectorsallowing these devices to be tested CPU identifying the devices which do not match and posting a quickly in the field. map fault.Through the 3-CPU 3'sRS-232 port a graphicalmap of The 3-SSDC1 and 3-SDDC1 local rail modules modules arefully the loopcan be uploaded depicting each device's location on the backwards compatible with the 3-SSDCand 3-SDDC localrail loop,including branches(T-Taps)and all of the physicalattributes modules.3-SSDC1 and 3-SDDC1 modules provide additional associatedwith the device.This diagnostic informationis unparal- onboard memoryto facilitate future Synergy functions.Toupgradea leled in the fire detection industry and vital for keep ingaccurate 3-SSDC/3-SDDC to a 3-SSDC1/3-SDDC1 respectively, replace the records on how the system was installed. 3-SSDC/3-SDDC Local Rail Module with a 3-SDDC1-MB LocalRail Module and reusethe 3-SDC Signature Device Cards and filters. Page 2 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 Typical Wiring 3-SSDC1,3-DSDC1,and 3-SDDC1 Class B wiring EE EE • c?"11:11 2 pi \ sly HE � :El`� � `�► ods L C_D • C_D SSSSSSSSSS ullu u u u u u u uuu TB1 BLJB SA Ag, B B A + - H + - KR + - LOOP1 LOOP1 1 LOOP1 3-SSDC1,3-DSDC1,and 3-SDDC1 Class A and Class X wiring r t I I I 1 osommilk __ Im 4E6,4 I C=D- 1. Fo r Class A wiring,isolatormodules and isolatordetectorbases are requiredto prevent wire- ' to-wireshorts on the signaling line circuit wiring fromadversely affecting other segments of the SSSSSSSSSS loop.Do not install more than 50 addressable devices between isolato rs,per NFPA 72. u u u u u u u2.For wiring B�u u uB S A A SP B e u TB1 g,isoatormodues and isolatordetectorbases are requiredto prevent wire- + - H + - KR + - m to-wireshorts on the signaling line circuit wiring fromadversely affecting any devices of the loop. LOOP1 LOOP1 1 LOOP1 3.Fo rClass X wiring,un-isolated devices must be mounted in a cabinet with isolators on the incoming and outgoing wiring. Engineering Specification The communication formatbetweenthe controlpanel and analog X with non-shielded,non-twisted wire.It must be possible to wire devices shall be 100% digital. branches(T-taps)with Class B wiring. Loopalarmrecognitionmust be within 750 milliseconds of a The driver controller must be manufactured in accordance with device going into the alarm state,with system responsetime no ISO 9001 standards. greater than 3 seconds.All devices shall sup portremotetesting. The system must have tolerance to multiple failures.There must It must be possible to wire the circuit as Class B,Class A or Class be a standalonemode of operationthat will ensure the system is aware of alarms even if the local rail or main CPU fails. Page 3 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 Sp ecificatio ns(Signature Circuits) Charts assume wire and devices are evenly distrib utedover length of circuit N on-twisted,non shielded wire Device type #of Detectors #of Module #14 AWG(20pf/foot) #16 AWG(20pf/foot) #18 AWG(20pf/foot) Addresses (2.53 Ohm/1000ft) (4.02 Ohm/1000ft) (6.38 Ohm/1000ft) Detectors only 125 0 14,752 feet 9,275 feet 5,839 feet (4,497 meters) (2,827 meters) (1,780 meters) Modules only 0 125 12,599 feet(3,840 7,921 feet(2,414 4,986 feet meters) meters) (1,520 meters) Detectors and Modules 125 125 5,738 feet 3,608 feet 2,271 feet (1,749 meters) (1,100 meters) (692 meters) Detectors and Modules 63 55+9 SIGA-UM 7,623 feet 4,793 feet 3,017 feet with 2-wire smokes (2,324 meters) (1,461 meters) (920 meters) Modules 0 107 +9 SIGA-UM 3,798 feet 2,388 feet 1,503 feet with 2-wire smokes (1,158 meters) (728 meters) (458 meters) Twisted pair non shielded wire #14 AWG 1.5mm2 #16 AWG 1.0mm2 #18 AWG Device Type #of Detectors #of Module (38pf/foot) (36pf/foot) (36pf/foot) (25pf/foot) (25pf/foot) Addresses (2.53 (3.75 (4.02 (5.51 (6.38 Ohm/1000ft) Ohm/1000ft) Ohm/1000ft) Ohm/1000ft) Ohm/1000ft) Detectors only 125 0 13,157 feet 9,933 feet 9,275 feet 6,760 feet 5,839 feet (4,010 m) (3,028 m) (2,827 m) (2,061 m) (1,780 m) Modules Only 0 125 12,599 feet 8,483 feet 7,921 feet 5,774 feet 4,986 feet (3,840 m) (2,586 m) (2,414 m) (1,760 m) (1,520 m) Detectors 5,738 feet 3,864 feet 3,608 feet 2,630 feet 2,271 feet &Modules 125 125 (1,749 m) (1,178 m) (1,100 m) (802 m) (692 m) Detectors and 7,623 feet 5,133 feet 4,793 feet 3,494 feet 3,017 feet modules with 63 55+9 SIGA-UM (2,324 m) (1,565 m) (1,461 m) (1,065 m) (920 m) 2-wire smokes Modules with 107 +9 SIGA- 3,798 feet 2,558 feet 2,388 feet 1,741 feet 1,503 feet 2-wire smokes 0 U M (1,158 m) (780 m) (728 m) (531 m) (458 m) Twisted pair shielded wire Device Type #of Detectors #of Module #14 AWG(84pf/foot) #16 AWG(82pf/foot) #18 AWG(58pf/foot) Addresses (2.53 Ohm/1,000ft) (4.02Ohm/1,000ft) (6.38 Ohm/1,000ft) Detectors only 125 0 5,952 feet 6,098 feet 5,839 feet (1,814 meters) (1,859 meters) (1,780 meters) Modules Only 0 125 5,952 feet 6,098 feet 4,986 feet (1,814 meters) (1,859 meters) (1,520 meters) Detectors&Modules 125 125 5,738 feet 3,608 feet 2,271 feet (1,749 meters) (1,100 meters) (692 meters) Detectors and modules 63 55+9 SIGA-UM 5,952 feet 4,793 feet 3,017 feet with 2-wire smokes (1,814 meters) (1,461 meters) (920 meters) Modules with 2-wire 0 107 +9 SIGA-UM 2,558 feet 2,388 feet 1,503 feet smokes (780 meters) (728 meters) (458 meters) Page 4 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 Sp ecificatio ns(controllers) Catalog N umber 3-SSDC1 3-SDDC1 Installation 1 LRM Space 1 LRM Space Module Configuration 1 Addressable circuit(3-SDC1 Card)expandable 2 Addressable circuits to 2 circuits. (3-SDC1 Cards) OperatingCurrent[Note 2] Standby 144 mA Alarm 204 mA Standby264 mA Alarm 336 mA OperatingVoltage 24 Vdc,Nominal Address Requirements Automatic Detectors Supported 125 per 3-SDC1 Card Modules Supported 125 Module Addresses per 3-SDC1 Card 2-Wire Smoke PowerOutput 100 mA per3-SDC1 Card(not included in Operating Current above Conventionaldetectorssupported 150 of 100 pA type per circuit. SignatureCircuit Voltage 20 VDC+/-5% Maximum SignatureCircuit Resistance 100 Ohms Maximum SignatureCircuit Capacitance 0.33 pF Communications Format 100% Digital Circuit Wiring Styles _ Class B,Class A or Class X Termination Removab lep lug-in terminalstrip(s)on module Permissable Wire Size 18 to 12 AWG(0.75to 2.5 mm2) Agency Listings UL,U LC(see Note 1); CE,LPCB,EN54(see Note 3). OperatingEnvironment 32°F(0°C)to 120 °F(49°C)93%RH,non-condensing Note 1: Other EST3 components are modularly listed under the following standards: U L864 catego ries:U OJZ,UOXX,UUKL and SYZV,U L294 category ALVY,U L609 category AOTX,U L636 category ANET,U L 1076 category APOU,U L365 category APAW,U L 1610 category AMCX,U L 1635 category AMCX U LC-S527,U LC-S301,U LC-S302,U LC-S303,ULC-S306,ULC/ORD-C1076,ULC/ORD-C693 Please refer to EST3 Installatio nand Service Manual for complete system requirements. Note 2:Currentshown Includes full loopof devices. Note 3:*ForEN 54-2:1997+Al:2006,EN 54-4:1997+Al:2002+A2:2006,and EN 54-16:2008 compliantproduct add suffix-E to model eg.3-SSDC1-E(verify deviceand loopcontroller compatibility). Ordering Information Catalog Description Shipping Wt. N umber lb(kg) 3 SSDC1 Single Signature Driver Controller.Comes with one 3-SDC1 Device Card.Mounts to LocalRail.Add suffix"-E"for 0.5(0.23) EN54 compliant versions. 3-SDDC1 Dual Signature Driver Controller.Comes with two 3-SDC1s. 0.5(0.23) Mounts to Lo cal R ail.Add suffix"-E"for EN54 compliant versions. 3 SDC1 Signature Device Card-upgrades a 3-SSDC1 to a 3-SDDC1. 0.25(0.11) Add suffix"-E"for EN54 compliant versions. 3-FP Filler Plate,orderseparately when no LED or LED/Switch module installed. 0.1 (0.05) Page 5 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 --t)WARDS LIFE SAFETY&INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: edwards-fire.com 1016 Corporate Park Drive Mebane,NC 27302 EDWARDS is a registered mark in the United States and other countries. ©2018 U nitedTechnologies Corporation. All rights reserved. Page 6 of 6 DATA SHEET E85010-0129 Not to be used for installation purposes. Issue 1.1 QM/2 ctcf Qlc LIFE SAFETY December 7, 2018 Mike Vaughan Fire Marshall —Town of Vail 2399 North Frontage Road West Vail, CO 81657 RE: Marriott—Vail, CO Fire Protection System —Owner Units/3rd, 4th, & 5th Floors Mr.Vaughan: Rondinelli Life Safety has reviewed the Fire Alarm drawings for owner's units #387/389, #393/395,#487/489, and #593/595. Our review has found that all coverage requirements are met and appear to comply with NFPA 72. Based on our review, Rondinelli Life Safety requests that the fire alarm subcontractor, AlarmSpecialists, be permitted to proceed with the installation "at risk" while TOFV reviews the submittal and issues a permit. If you have any questions or concerns, please feel free to contact me at 303.748.5846. Prepared By: Shaun Rondinelli Life Safety Specialist Rondinelli Life Safety Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn Rondinell iLifeSafety.corn QM/2di/Qlc LIFE SAFETY Reviewed By: 4�pF C0Z09 94 c� TEP HEN 0 1.4 I TON 4 * �► 47 � V FD R Grah wrihar Stephen Rondinelli, AIA Rondinelli Life Safety C.C. Cody O'Kelly Principal OCG: Design. Construct. Manage PO Box 5686 Eagle, CO 81631 Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn Rondinell iLifeSafety.corn