Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0069_Approved Documents_1544571386.pdf
75 South Frontage Road Fire -Construction Permit West, TOWN OF VAIL A18-0069 Vail, CO 81657 Issued: 12/11/2018 TOWN of VAILOFOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 9 VAIL RD 3A(210 10 710 60 19) Unit#:3A Parce(Number: 210107106019 LegalDescription: Subdivision: HOLIDAYHOUSE Unit:3A R736489 EAS 08-11-00R906005 EAS 02-11-05R917475QCD 05-04-05 R200609609 EAS 04-14-06 Contacts ContactType: Applicant Full Name: Clint Bartels Address: PO Box 883 303 CountyRoad 265 Rifle,CO 81650 Phone: 9706253398 ContactType: PropertyOwner Full Name: ADELA INTERNATIONAL INC VAIL REALTY Address: 302 HANSON RANCH RD 3A VAIL,CO 816573627 Phone: None Contractor Contractor Type: Alarm Company: Acme Alarm Company State License#: Phone: 970-625-3398 Projectlnformation ProjeciName: Adela International Inc 2018 ProjeciDescription: Move Smoke detector,move horn-strobe,add CO detector Fees Paid Account#:001-0000.31111.00-Fire Scope LetterFee Fee Amount: $216.00 TotalPaid: $216.00 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # A18-0069 Date Printed: 12/10/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0069 Status: Created Permit Number: Date Started: 12/06/2018 Permit Type: Fire-Construction Permit Subc ases Fire Alarm Lot Number: B Property: 9 VAIL R D 3A(210107106019) Contacts Contact Type: Applicant Company Name: Acme Alarm Company Full Name: Clint Bartels Address: PO Box 883 303 County Road 265 Rifle,CO 81650 Email: clint@acmealarm.com Contact Type: Property Owner Full Name: ADELA INTER NATIONAL INC VAIL REALTY Address: 302 HANSON RANCH R D 3A VAIL,CO 816573627 Permit Fees Fee Information Account Amount Fire Scope Letter Fee 001-0000.31111.00 $216.00 Payment Information Date Paid Payment Type Amount Fire Scope Letter Fee 12/10/2018 Credit Card $216.00 Paid By: -Notes:Visa-Clint A Bartels FEE TOTAL $216.00 AMOUNT PAID $216.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 12/10/2018-3:39:00 PM-Generated by:do ouc h 1/1 macuRco MacurcoTM Carbon Monoxide Detector GAS DETECTION cm - El ' U , „ii cu cm, SIGNALING U` For use with alarm controlpanels LISTED Carbon Monoxide Detection The CM-E1 is a low voltage detectorof Carbon Monoxide (CO).The CM—E1 is designed forconnectionto UL ListedFireAlarm/Burglary Control Panels.Alarm controlpanels that work on 12 or 24 VDC can provide battery backup to the CM-E1 detectors. This carbon monoxide detectoris designed to detect CO gas fromANY source of combustion.It is NOT designed to detect smoke,fireor any other gas. Features • Listed to UL standard 2075 for the Standard For Safetyfor Gas and VaporDetectorand Sensors • Tested to UL 2075 using UL 2034 Sensitivitylimits for carbon monoxide gas • CaliforniaState Fire Marshal Listed • Surface mounts to a wall using the supplied enclosure rear housing • Flush mounts in a 2 x 4 (1-3/4 inch deep minimum) single gang switch, or handy electricalbox • Small, low profile,attractive unit in a white plasticcase /\ E R I O N ICS • Detectoralarms at multiple levels of exposureto carbon monoxide based on time weighted averagesof the gas present • Test & Reset switch conducts internal tests and actuatesalarm relay • 10 year electrochemical sensor • N.O. or N.C. SPSTAlarm Relay and N.C. SPSTTroublerelayto connect to Alarm Control Panels • Buzzer:Produces repeating loud tone burstsduring alarm,and chirps if sensor trouble is found Manufactured byAerionics,Inc. Sioux Falls, SD—Phone: 1-877-367-7891—Email: info@aerionicsinc.com —www.macurco.com CM-E1 Specifications • Voltage:9-32VDC • Current(normal/ alarm): 15mA / 35mA@ 9-32V 1 ;, t • Size: 3-1/8X 5-1/8 X 1-3/4 inch (7.94 x 13.02 x 4.45 cm) F •Alarm Relay:SPST,100mA, 40VDC '+r „. • TroubleRelay:SPST,100mA, 40VDC F • Buzzer Rating:85 dBA at 10 Feet -- • Shipping Weight:One pound • OperatingTemp.Range: 40°F (4.4°C)to 100°F (37.8°C) •Alarm Setting: Per UL 2034 • Color:White • Designed for use with a UL Listed FireAlarm/Burglary Control Panel Installation With the CM-E1 faceplate mounted on the enclosure's rear-housingthe unit can be surface mounted on a wall. A thin mid-plate enclosure component is also supplied with the CM-E1 to mount the CM-E1 on a 2 x 4 inch (5.08cm x 10.16 cm)switch box- single-gang or"handy", provided by the installer. Location There are two usual sources of CO - defective heat sources(furnaces or wood burning stoves)and automobiles running in adjoining garages.The CM-El can detect CO fromthese sources,as well as any other sources of CO. For bestoperation,mount a CM-E1 in the hallway near each bedroom or office area.In addition, anotherCM-E1 may be mounted just inside the door fromthe adjoining garage.Consider placing anotherdetectorin a bedroom or office that is adjacent to a furnace room.The detectormay be installed on either a ceiling ora wall. If installed on a peaked,gabled, or sloped ceiling, it should be located about 3 feet(1 meter)fromthe highest point.The unit can be placed vertically or horizontallyon a wall, so the information on the frontof the CM-E1 can be read in a normal manner(not upside down). Do NOT mount the CM-E1 in a corner. Use the same spacing as for smoke detectors - 30 foot(9 meters)centers,900 sq. feet(84 sq. meters)per detector. TYPICALCONNECTION OF TWO CM-E1 TOAN ALARMCONTROLPANEL TYPICALCOVERAGE900 SQUARE FEET UL Listed Alarm Control Panel CM-El I CM-El N.O. initiating ALARM Blue ALARM Blue Circuit Yellow — Yellow ALARM ALARM rn T0 Battery-backed 12 or 24Gray Gray VDC Power Supply.Fuse ® COMMON COMMON or current limit at 0.2 A for TROUBLE Green TROUBLE Green each CM E1 0 ._ Black(-) ♦ Black(-) GND GND • Red(+) GND � Red(+) PWRPWR I Made in the U.S.A.with US and imported materials GAS DETECTION ©Aerionics2015.All rights reserved. I ` 1- Macurcois a trademark ofAerionics,lnc. Made in the USA SYSTEM �$ SENSOR `5` +41 Selectable-Output x1.4 Horns,Strobes,and Horn Strobes f F SpectrAlert®Advanceselectable-outputhorns,strobes, and horn strobesarerichwith features guaranteedto cut installation timesand maximizeprofits. SPECTP A pert 4141,4, A N Features The SpectrAlertAdvanceseriesoffersthe most v ersatileand •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobesin the industry. With white and red plastic housings,wall and ceiling mounting •Tamper-resistant construction options,and plain and FIRE-printed dev ices,SpectrAlert Advancecan •Automatic selection of 12-or 24-v oltoperation at 15 and 15/75 meet v irtuallyany application requirement. candela •Field-selectablecandela settings on wall and ceiling units:15, 15/75, Likethe entireSpectrAlert Advanceproduct line,horns,strobes, 30,75,95, 110, 115, 135, 150, 177,and 185 and horn strobesinclude a varietyoffeaturesthat increasetheir •Horn rated at 88+dBA at 16 volts application versatilitywhile simplifyinginstallation.All devices featureplug-in designs with minimal intrusion into the back •Rotaryswitch for horn tone and threev olumeselections box,which make installations fast and foolproofwhile virtually •Univ ersalmounting plate forwall and ceiling units eliminating costlyand time-consuming ground faults.Furthermore, •Mounting plate shorting spring checkswiring continuity before a univ ersalmounting plate with an onboard shorting spring tests dev iceinstallation wiring continuity before the dev iceis installed,protectingdev ices •Electricallycompatiblewith existing SpectrAlert products fromdamage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12- or 24-v oltoperation,and a rotaryswitch for horn tones with threev olumeselections enables installersto easily adapt dev icesto suit a wide range of application requirements. Agency Listings SIGNALING 0 ® MEA approved : ( ) LISTED APPROVED 7125-1653:1887125-1653186(hornstrobes,indoorstrobes S4011(chimes,hornstrobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlertAdvanceSpecifications Architect/Engineer Specifications General SpectrAlert Adv ancehorns,strobes,and horn strobes shall mounttoa standard4 x 4 x 11-inch back box,4-inch octagon back box,ordouble-gang back box.Two-wire productsshall also mountto a single-gang 2 x 4 x 17/8-inch back box.A univ ersalmounting plateshall be used formountingceilingand wall products.The notificationappliancecircuitwiringshall terminateat the universalmounting plate.Also,SpectrAlert Adv anceproducts,when used with the Sync•Circuit'"Module accessory,shall be poweredfrom a non-coded notificationappliancecircuitoutputand shall operateon a nominal 12 or 24 volts. When used with theSync•CircuitModule,12-volt-ratechotificationappliancecircuitoutputsshall operatebetween9and 17.5 volts;24-volt-rated notification appliancecircuitoutputsshall operatebetween 17 and 33 v oltsindoor SpectrAlertAdv anceproductsshall operatebetween32 and 120 degrees Fahrenheit from a regulated DCor full-wave rectifiedunfilteredpowersupply.Strobes and horn strobes shall hav efield-selectablecandela settings including 15, 15/75,30, 75,95,110, 115, 135, 150,177,and 185. Strobe The strobeshall be a SystemSensorSpectrAlertAdv anceModel listed to UL 1971 and shall be approved forfire protective sery iceThestrobeshall be wiredas a primary-signaling notificationapplianceand complywith the Americanswith Disabilities Act requirements fory isiblesignaling appliances,flashing at 1 Hzoverthestrobe'sentireoperatingvoltagerange.Thestrobelightshall consistofaxenonflash tube and associatedlens/reflectorsystem. Horn StrobeCombination The hornstrobeshall bea SystemSensorSpectrAlert AdvanceModel listed to UL 1971 and UL464and shall be approved forfire protective sery iceThe hornstrobeshall be wiredas a primary-signaling notificationapplianceand complywiththeAmericanswith Disabilities Act requirements fory isiblesignaling appliances,flashing at 1 Hzoverthestrobe'sentireoperatingvoltagerange.Thestrobelightshallconsistofaxenonflashtubeandassociatedlens/reflector system.The horn shall hav ethreeaudibilityoptionsand an optionto switch betweena temporalthree-pattern and a non-temporal(continuous)pattern.These optionsareset bya multiplepositionswitch.Onfour-wire products,the strobeshall be powered independentlyofthe sounder.Thehorn on horn strobemodels shall operateon a coded or non-coded powersupply. Synchronization Module The module shall be a System SensorSync•Circuitmodel MDLlistedto UL464and shall be approved forfire protective sery iceThe module shall synchronize SpectrAlert strobes at 1 Hz and hornsat temporalthree.Also,whileoperatingthe strobes,the module shall silencethe hornson horn strobemodels ov era single pair of wires.The module shall mountto a 411/16 x 411/16 x 21/8-inch back box.The module shall also controltwoStyleY(classB)circuits or one StyleZ (classA)circuit.The module shall synchronize multiplezones.Daisychainingtwoor moresynchronization modules togetherwill synchronize all thezonesthey control.Themodule shall not operateon a coded powersupply. Physical/Electrical Specifications StandardOperatingTemperature 32°F to 120°F(0°Cto 49°C) Humidity Range 10 to 93%non-condensing StrobeFlash Rate 1 flash per second NominalV oltage Regulated 12 DC/FWRor regulated24 DC/FWR1 OperatingV oltageRange& 8 to 17.5 V(12 V nominal)or 16 to 33 V(24V nominal) InputTerminalWireGauge 12 to 18 AWG Ceiling-MountDimensions(includinglens) 6.8"diameterx 2.5"high(173 mm diameterx 64 mm high) Wall-MountDimensions(includinglens) 5.6"L x 4.7"W x 2.5"D(142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6"Lx4.7"W x 1.3"D(142 mm Lx 119 mm W x 33 mm D) Wall-MountBackBoxSkirtDimensions(BBS-2,BBSW-2) 5.9"L x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Ceiling-MountBackBoxSkirtDimensions(BBSC-2,BBSCW-2) 7.1"diameterx 2.2"high(180 mm diameterx 57 mm high) Wall-MountTrimRingDimensions(soldas a 5 pack)(TR-HS,TRW-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Ceiling-MountTrimRingDimensions(soldas a 5 pack)(TRC-HS,TRCW-HS) 6.9"diameterx 0.35"high(175 mm diameterx 9 mm high) Notes: 1.FullWav eRectified(FWR)v oltageis a non-regulated,time-v aryingpowersourcethat is used on some powersupplyand panel outputs. 2.P,S,PC,and SC productswilloperateat 12 V nominalonlyforl5 and 15/75 cd. A05-0395-007 UL C urrentDraw Data UL Max.StrobeCurrent Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5Volts 16-33Volts 8-17.5Volts 16-33Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-WireHorn Strobe,StandardCandelaRange(15-115 cd) 8-17.5 V olts 16-33Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-WireHornStrobe,High Candela Range(135-185 cd) 16-33Volts 16-33Volts DClnput 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tonesand Sound Output Data Horn and Horn StrobeOutput(dBA) 8-17.5 16-33 24-V oltNominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not availableon 2-wire horn strobe. A05-0395-007 SpectrAlertAdvance Dimensions 1.-4.7" 2.5=0 I6.8'a.FIL Di - Fft if.. --,-,k i! 561) m� 1� �. - Wall-mounthorn strobes Ceiling-mounthornstrobes 7.1" 2.25+1 5.05 �-2.23�I \ Dia. 14-2.251 0 I i I I 7 O o0 r 90oaa , r(- 5.98' 0 0 l O 00 110 ¢ r \\O id� Q O �O Q C .� Wallbackboxskirt Ceilingbackboxskirt SpectrAlertAdvanceOrdering Information Model Description Model Description WallHornStrobes CeilingStrobes P2R*r 2-Wire Horn Strobe,Standardcd*,Red SCR Strobe,Standardcd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2W* 2-Wire Horn Strobe,Standardcd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standardcd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4-Wire Horn Strobe,Standardcd,White HW Horn,White Wall Strobes Accessories SR** Strobe,Standardcd,Red BBS-2 Back BoxSkirt,Wall,Red SRH*t Strobe,High cd,Red BBSW-2 BackBoxSkirt,Wall,White SW* Strobe,Standardcd,White BBSC-2 Back BoxSkirt,Ceiling,Red SWH* Strobe,High cd,White BBSCW-2 Back BoxSkirt,Ceiling,White CeilingHornStrobes TR-HS TrimRing,Wall,Red PC2R* 2-Wire Horn Strobe,Standardcd,Red TRW-HS TrimRing,WallWhite PC2RH 2-Wire Horn Strobe,High cd,Red TRC-HS TrimRing,Ceiling,Red PC2W*t 2-Wire Horn Strobe,Standardcd,White TRCW-HS TrimRing,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standardcd,Red PC4RH 4-Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standardcd,White Notes: *Add"-P"to model numberforplain housing(no"FIRE"markingon cover),e.g.,P2R-P. t Add"-SP"to model numberfor"FUEGO"markingon cover,e.g.,P2R-SP. t"Standardcd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings"H igh cd"refers to strobes that include 135,150,177,and 185 candela settings. *--Th_ SYSTEM ®2009 System Sensor. 38250hioAvenue•St.Charles,IL60174 ProductspecificationssubjecttochangewithoutnoticeVisitsystemsensoccomfor V SENSOR Phone:800-SENSOR2•Fax:630-377-6495 currents roductinformation,includingthelatestv ersiorofthisdata sheet. A05-0395-007.4/09•#2132 �Gamewell Series 95 Bases Fe' FIRE TRUMENTS CONTROL INS by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base,the XP95 *y family has a base to meet building aesthetics,constraints, 11‘ retrofit limitations or functional needs. The device address L • is held in the base, ensuring that the device address will ° f not be changed no matter how often a detector is replaced, •_ and verifying a consistent match between device type and 4L4 device address. Each XP95 analog addressable head is compatible with a wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only"fit. Relay and sounder bases can be addressed and • Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. • Base options include: — 4.0"(10.16 cm)or 6.0" (15.24 cm)ultra-low-profile Programming bases feature"one-way"fit with low insertion force — 6.0"(15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group • The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base • head is inserted into the base,the address is automatically Address is set by patented XPertaddressing card • relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors.The bases SIGNALING have a wide interior diameter for ease of access to wires 0 and terminals.The design of the base is such that the LISTED S1195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are f or informationonly,are not intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed byGamewell-FCI fortheir use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.a 1 page 1 of 2 Installation(Continued) Specifications (Continued) sensor will fit in only one way, and a simple clockwise motion (without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Model:XP95-B6R4 XPert addressing card as a means for programming and Alarm Current: 0.0036A maintaining the sensor's address. StandbyCurrent: 2 pA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-B4 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Capt iveTerminals: Yes cover/plaster ring(Raco 727 or equal). The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5"(8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model:XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030A square backbox(Raco 190 or equal). StandbyCurrent: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048m) Capt iveTerminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-I) or photoelectric (Gamewell-FCI model XP95-P)smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-B4 4.0" (10.16 cm)mounting base with model XP95-T)with one of the several addressable mount XPert addressing card (four- ingbase available options. The combination sensor head XP95-B6R4 6.0" (15.24 cm)relay base p wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0" (15.24 cm)ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED(24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: XP95-B4 Alarm Current: N/A StandbyCurrent: N/A Relay Rating: N/A Sounder Level: N/A Capt iveTerminals: Yes 6" Base Model: XP95-B6EZ Alarm Current: N/A StandbyCurrent: N/A Relay Rating: N/A Sounder Level: N/A Capt iveTerminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2048 Rev.a1 page 2 of 2 www.gamewell-fci.com Gamewell XP95-P Fe' FIRE TCORUMENTSLNTRO INS by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- tric sensor operates with the Gamewell-FCI analog addres- sable Fire Alarm Control Panels (FACPs). The photoelectric sensor digitally transmits its address and the • chamber's analog values to the FACP for analysis. The ;`• . photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled • and turns on continuously when the device is in alarm. _'— I J� Operat ion Ow- • The XP95-P photoelectric sensor constantly monitors its _ sensing chamber and its internal electronics. The results are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber.When • Fits 4.0"(10.16 cm)or 6.0" (15.24 cm)ultra-low-profile smoke enters the chamber,it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- • Audible alarm sounder base acteristics and density.As the smoke content in the cham- • Four-wire relay base ber increases, the signal from the photo diode receptor • Address is stored in the sensor base increases. This information is processed and conditioned • Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally • Two-color status LED transmitted to the FACP. • Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are • Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. ® MEA LISTED Approved S1195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are f or informationonly,are not intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed byGamewell-FCI fortheir use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2054 Rev.a1 page 1 of 2 Operation(Continued) Ordering Information The XP95-P photoelectric device is connected to a two- Model Description wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor,analog voltage, and is insensitive to loop connection polarity. A addressable(55000-650) remote LED indicator may be connected. The device is XP95-B4 4.0" (10.16 cm)mounting base with compatible with point-or group-addressable relay and XPertaddressing card(45681-2101) sounder bases. XP95-B6R4 6.0" (15.24 cm)relay base (four-wire)with XPertaddressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install, where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available.The 30203 Remote LED(24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications St andbyCurrent: 340 pA Alarm LED Current: 0.00434 A RemoteAlarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F (0° C to 60° C) RelativeHumidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft.(9.1 m)spacing guidelines in NFPA72 Chapter 2. However, this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.a1 page 2 of 2 www.gamewell-fci.com Gamewell PID-95P,PID-95 Fc' FIRE TRUMENTS CONTROL INS by Honeywell Description Point Identification Device The Gamewell-FCI PID-95P addressable point identifica- tion device is the interface between the non-powered, nor- mally open, dry-contact devices and Gamewell-FCI's 600 Series and IL195-E3 Series° of analog addressable Fire „Gamewell-FCI Alarm Control Panels (FACPs). Point identification devices PID95P LI monitor a single Style B circuit,and are designed for con- •,OL 1 cealed mounting in an electricalbackbox.The PID-95P can PD-15P 57 be surface or flush mounted and has a visible LED for o I I $' alarm/annunciation. Operation l , PID-95P PID-95 The point identification device connects to the Signaling Line Circuit (SLC) via two wires. The PID-95 will monitor, via a two-wire supervised SLC circuit,contact-type devices Features such as a waterflow switch or a manual station. Upon acti- vation of the monitored device, the PID-95 will report its address to the 600 Series and IL195-E3 Series FACP via • Compatible with the Gamewell-FCI, 600 Series and the analog SLC. The control panel will then activate into all IL195-E3 Series Systems alarm programmed outputs related to the PID-95. • Monitors dry-contact devices Programming • LED for alarm annunciation • Field programmable The PID-95 is programmed by setting a single DIP switch, • Priority interrupt easily accessible on the device's printed circuit board. The • Plate-mounted version available for surface or flush DIP switch sets the address of the device and the priority mounting in a 4"x 4.688" (10.16 cm x 11.908 cm)double interrupt (DIP SW #8). All other programming is accom- plished at the FACP through a laptop computer or the con gang backboxor 4"x(10.16 cm)square backbox trol panel operator's display.(600 Series only). StandardApplication The PID-95 is the interface between the dry-contact type devices and the SLC of the control panel. The PID-95 is a means of connecting and identifying monitor points without the use of conventional input modules at the main control panel.The use of PID-95s can dramatically reduce the field wiring required on many projects. An ISO 9000-2000 Company SIGNALING E3 Series®is a registered trademark of Honeywell Internationallnc. 0 fOo Microsoft®Windows®is a registered trademark of Microsoft®Corporation. LISTED® MEA $521 APPROVED Approved 7300-1703:135 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are f or informationonly,are not intended forinstallation purposes,and are subject to change without notice.No responsibilityis assumed by Gamewell-FCI fortheir use. ©2008 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2044 Rev.B page 1 of 2 Engineer's Specifications Ordering Information Addressable interface devices shall be provided for the monitoring and supervision of contact type devices con- Part NumberDescription nected to the Fire Alarm Control Panel. The devices shall PID-95 Addressable point identif ication device monitor a normally open dry contact. The addressable for monitoring contact devices interface devices shall communicate to the main control PID-95P Addressable input interface device panel via the analog addressable circuit. The interface mounted on 4.688" (11.908 cm)plastic plate device shall be Gamewell-FCI PID-95Por PID-95. 70839 Trim ring for flush-mounting on the PID 95P Specifications PID-95P Standby Current: 0.0005A, 0.0008A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93%,non-condensing Dimensions: 4"x 4.688" (10.16 cm x 11.908 cm), double gang backbox PID-95 Standby Current: 0.0005A, 0.0008 A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93%,non-condensing Dimensions: 4"(10.16 cm)square backboxwith blank cover plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2044 Rev.B page 2 of 2 www.gamewell-fci.com Fire and Emergency Services 2399 N. Frontage Road W. Vail, Colorado 81657 TOWN OF UA I It A Tel: 970-479-2252 www.vailgov.com Fire& Emergency Services Fire Marshal FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: Office Use: t/�;\ R40a S.> (Number) (Street) (Suite#) Project#: rV� C9 , / ` 1 Building Permit#: Building/Complex Name: j11 0. Alarm Permit#: Contractornformation: Lot#: Block# Subdivision: e Company: -V`r1 Q ' 1 lit Y`Cl C.INA\ Ckdll\ Company Address: Q 0 b63,gS Detailed Scope and Location of Work: ;^ incl . RCity: i4t(1 P State: CO Zip: UOsv Sr,t •..e f114.--ke_C-/- nrAof (-ior✓t Contact Name,[Qne.st,��U5Oh � L doe__o� n -,3,-..," la c.-ioi#, Contact Phone: Ck��-`9 dS"' 3 �1� Adel I ((1 r I i .1 . '-)fir' �' ,-t. t (use additional sheet if necessaty) E-Mail grpvCZ ekcytAkq,\c J w► .COv \ Does a Monitored Fire Alarm Exist? Yes(() No(n) I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate fire alarm sys- Does a Sprinkler System Exist? Yes NI No(n) tern drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system Work Class: drawings,to comply with all Town ordinances and state laws,and to - build this structure according to the towns zoning and subdivision New( ) Addition ( ) Remodel X) Repair ) codes, design review approval, National Fire Code, International Retro-Fit(—) Other(I—) Building and Residential Codes and other ordinances of the Town applicablPubreto. Type of Building: X 5- ..., _ Single-Family 4') Duplex r) Multi-Family(s- ) Commercial(Ni Restaurant(F) Other(F) Contractor Si! ature(required) Property Information Complete Valuation for Fire Alarm Permit: Parcel#: Fire Alarm$: Z, c c (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: Date Received: Owner Name: 2014-0916