Loading...
HomeMy WebLinkAboutB06-0119 TOWN OF VAIL DEPARTMENT OF COMMUNITY Dt��ELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Permit #: B06-0119 Project#: PRJ06-0007 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL �, lied . . : OS/10/2006 Location.....: 4367 STREAMSIDE CR, Units 5&6 Ip ued . . . •8��e�=�� � '6�,�- Parcel No...: 210112305012 Expires.....: 12/12/2006 OWNER STREAMS IDE C IRCLE PARTNERSHI 0 5/10/2 0 0 6 1��� � 3033 E 1ST AVE STE 815 �r` � '�-�,� �� DENVER � ��`�"`�W` CO 80206 APPLICANT R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DRAWER 5400 AVON Colorado 81620 License: 170-A CONTR.ACTOR R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DRAWER 5400 AVON Colorado 81620 License: 170-A Desciption: NEW CONSTRUCTION OF A DUPLEX AND SITE IMPROVEMENTS TRILOGY UNITS 5 AND 6 Factor Sq Feet Valuation Occupancy T�e 9, 363 $1, 275, 611. 00* Totals. . . Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,275,611.00 Revision Valuation: $0•4� ******�*�**********************�********************�************ FEE SUMMARY*****�:****�*****�:*:�***�************************************ 0.00 Total Calculated Fees-----> $12,599.10 Building------> $6,616.15 Restuarant Plan Review--> $ $0.00 4,300.50 RecreationFee------------> $1,404.45 AdditionalFees------------> Plan Check---> S > $i2,599.io Investigation-> $0.oo TOTAL FEES-------------> $12,599.10 Total Permit Fee-----------> $12,599.10 Payments------------------- $o.0 0 Will Call-----> $3.00 BALANCE DUE---------> ****************�****�:**********�******************�******************�*********�************************:�*********************************�*�*** Approvals: Item: 05100 BUILDING DEPARTMENT Action: COND SEE COND 06/05/2006 cgunion roved revised drawings 02/08/2007 jplano Action: AP APP lans when 02/15/2007 jplano Action: CR Will need to re-review the p resubmitted for planning roved 03/01/2007 jplano Action: AP Revised drawings app Item: 05400 PLANNING DEPARTMENT Action: AP 06/14/2006 ee 02/14/2007 bgibson Action: AP 02/13/07 dimising wall revision roval 02/15/2007 bgibson Action: DN revision do not comply with DRB app 03/O1/2007 bgibson Action: PA revisions Item: 05600 FIRE DEPARTMENT 06/07/2006 JJR Action: COND See conditi�ns. Item: 05500 PUBLIC WORKS 06/09/2006 gc Action: AP 02/09/2007 gc Action: DN Same as B06-0119 03/O1/2007 CSalli Action: AP Irrigation mains shall not be located within ROW Item: 05550 ENGINEERING CIVILS *********************************************************************************�**�************************************************************ See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and Res dent al Code and other�ordinances of the Town ppl cable the eto.des, design review approved, International Buildmg and REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SI / OWNER O Ai-'F OR FOR HIIVISELF AND OWNEF ���*������������***�����*��*�*����*�*�*��*�����*�*����*�*�*����*��*�*�*���*�*�*��***�*�*��*�*����*�����* CONDITIONS OF APPROVAL Permit#: B06-0119 as of 03-01-2007 Status: ISSUED �:�x�*�*��*�:�**��x*��x*�*�*:��x�*��*�*�:*�*�:*��x***����*��:*�:*����x�*����*��**�:***�x�����*�*����*��:*�:****�*�*�*�x�x�* DUP) PERMIT Applied: OS/10/2006 Permit Type: NEW (SFR,P/S, Issued: 06/15/2006 , Applicant: R.A. NELSON & ASSOCIATES, INC Job Address: 4367 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR, Units 5&6 Parcel No: 210112305012 **����x�*�*�x���*��x���x�*�*�x����x��x*�:�x=x�x�����x*�*�x�x�x�:*�:�x��x��*�x*�*�:*�*����x�x��x�*��x�:��*���:�x��x���:�*���*�������x��* CONDITIONS �x�**�����*�x��:*��x*��*�*����:*���:���*��:���x����*��x��*�:���x*�*�*�:��*=��*=����x��:x���x��x��x���x�x��*�*����x��x*�:��*�x*���x Cond: 33 (PLAN) THIS PROJECT WILL VED PRIOR TO REQUEST�FOR A FRAME I SPECT ON RVEY SHAL BE SUBMITTED AND APPRO Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 39 (BLDG): EMERGENCY ESCA N OS OF THE 2003 IBCNGS ARE REQUIRED TO MEET SECTION R31 OF THE 2003 IRC OR SECTIO Cond: CON0008113 CONDITIONS OF APPROVAL: 1) GUARDS REQUIRED AT ALL WINDOW WELLS ADJACENT TO WALKING SURFACES AND PATIOS PER IRC R312 2) EGRESS WINDOW REQUTAILll 0 A9.03SIS NOT�A�PPROVEDYCOMPLOETE FIREPLACEIRC R310 3) MASONRY FIREBOX DE SUBMITTAL REQUIRED WITH MECHANICAL PERMIT. 4) VERIFY ALL BASEMENT EGRESS WINDOWS PER IRC R310 BASEMENT LEVEL WINDOWS NOT SHOWN ON ELEVATIONS. Cond: CON0008126 Fire sprinkler system required and shall comply with NFPA 13R and VFES standards. Cond: CON0008127 Monitored fire alarm system required and�shall comply with NFPA 72(2002) and VFES standards. Cond: CON0008168 Prior to TCO, the applicant shall record with Eagle County and the Town of Vail language for a permanent easement to the Town for that portion of Lot 6 which is lcoated within the Town's right-of-way along Streamside Circle. Cond: CON0008169 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall comply with all restrictions specified by the Town of Vail Fire Department. Cond: CON0008170 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall record with Eagle Counry and the Town of Vail new plats for each of the lots which designate easements for both parking and cross access B06-0119: Entries for Item:90 - BLDG-Final 14:52 05/31/2013 Action Comments By Date Unique_ Ke AP SHAHN 11/21/2007 A000108 433 Total Rows: 1 Page 1 and an easement for the proposed drainage between Lots 7 and 8. *��****�*****�**�***********��****�***�*********************�*******�***********�***�******� Statement TOWN OF VAIL, COLORADO *********�x**********�:�**�:*�****�:�*�*********�*��x**�*:�*+*�*******�x**************:�******�***** Statement Number: R070000220 Amount: $275.00 03/O1/200703 :02 PM Payment Method: Check Init: DDG Notation: RA Nelson 17144 ----------- Permit No: B06-0119 TYP e: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-123-0501-2 Site Address: 4367 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR, Units 5&6 Total Fees: $12,599.10 This Payment: $275.00 Total ALL Pmts: $12,599.10 Balance: $0.00 **�**�x************�****************�***:�********************�x�**�:****************:x�********* ACCOLTNT ITEM LIST: Current Pmts Account Code Description ------------------------------ ----- 275.00 PF 00100003112300 PLAN CHECK FEES ------------------------------------- u AP CATION WILL NOT BE ACC PT IF INCOMPLETE OR UNSIGNED Building Permit#:_� D�" ��� � 970-�t79-2149{lnspections) v�i�S g� « � � . � � '�?�����i�z� REVISION TO TOWN OF VAIL BUILDING P E R M I T Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 ***All Revision submittals must include the Field Set of approved plans.�No fur#h�r.inspections will be preformed until the revisions are approved. � _ CONTRACTOR INFORMAT90N � ' General Contractor: Town of Vail Reg. No.: Contact and Phone#'�: � � �. � �Z Z-- ATTENTION: JQE,JR,CHARLIE,GREG,CHRIS Contractor Signature: � c�— COMPLETE RE ISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANtCAL: $ REVISED TOTAL: $ For Parcel# Contact Ea le Coun Assessors t�ffice at 970-328-8640 or visit www.ea le-count .com ParGe(# Job Name: Job Address: (^ L�� Legal Description Lot: Block: Filing: Subdivision: Phon�: Ow f Name: e Address:. p . � hJ� o !b � �- Phoneo.� � � ArchitecUDesigner� Address: -- L� .Fv n� o.� Enginee� � t� �ess� �� � � Phone�o L,� REASON FOR REVISIONS: ��� Work Class: Nevv Addition ( ) Remodet ( ) Repair( ) Demo( ) Other( ) Work Type: Interior( ) Exterior( ) Both Does an EHU exist at this tocation: Yes ( ) No � ) Ftestaurarit Other Type of Bldg.: Single-family( ) Two-family Multi-family( ) Commercial( ) � ) � No. of Existing Dwelling Units in this building: `� No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances � Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet S S em F B t ninYe OT)ALLN WED Does a Fire Alarm Exist: Yes ( No( ) Does a Fire Sprinkler y ***k********FOR OFFICE USE ONLY Occu anc Gro�____� Acce 'ted B :' Other Fees: ' --p--�--p� Type of Constcuction: Date Received: Pa e 1 of 2 12/8/2005 F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc 9 TOWN OF VAIL DEPARTMENT OF COMMUNITY DhVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Perrriit #: B06-0119 Project#: PRJ06-0007 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL �, lied . . : OS/10/2006 Location..:..: 4367 STREAMSIDE CR, Units 5&6 Is ued . . . 06/15/2006 Parcel No...: 210112305012 Expires.....: 12�12�2006 OWNER STREAMSIDE CIRCLE PARTNERSHI05/10/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DRAWER 5400 AVON Colorado 81620 License: 170-A CONTRACTOR R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DR.AWER 5400 AVON Colorado 81620 License: 170-A Desciption: NEW CONSTRUCTION OF A DUPLEX AND SITE IMPROVEMENTS TRILOGY UNITS 5 AND 6 Factor Sq Feet valuation Occupancy T�e 9, 363 $1,275, 611.00* Totals. . . Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,275,611.00 Revision Valuation: $0.00 FEE SUMMARY*�:*�***************************************************�*** 12,599.10 **********�:****�*�****�:*********************************�**�***** $0.00 Total Calculated Fees-----> $ $0.00 Building------> $6,616.15 RestuarantPlanReview--j $1,404.45 AdditionalFees------------> 4,3 0 0.5 0 Recreation Fee------------ • � $12,5 9 9.10 Plan Check---> $ � $12,5 9 9.10 Total Pernut Fee-----------> $12,5 9 9.10 Investigation-> $o.0 o TOTAL FEES------------ payments------------------- $s.00 $o.00 Wili Call-----> BALANCE DUE--------> **�****�**************�**�:*�*****************�***��***�*�***************�**************�*********�***********�**�***�**********�*****�****�:****�* Approvals: Item: 05100 BUILDING DEPARTMENT Action: COND SEE COND 06/05/2006 cgunion Action: AP Approved revised drawings 02/08/2007 jplano lans when resu: 02/15/2007 jplano Action: CR Will need to re-review the p for planning roved 03/01/2007 jplano Action: AP Revised drawings app Item: 05400 PLANNING DEPARTMENT Action: AP 06/14/2006 ee Action: AP 02/13/07 dimising wall revision 02/14/2007 bgibson roval 02/15/2007 bgibson Action: DN revision do not comply with DRB app 03/O1/2007 bgibson Action: PA revisions Item: 05600 FIRE DEPARTMENT 06/07/2006 JJR Action: COND See conditions. Item: 05500 PUBLIC WORKS 06/09/2006 gc Action: AP 02/09/2007 gc Action: DN Same as B06-0119 03/01/2007 CSalli Action: AP Irrigation mains shall not be located with 03/19/2007 gc Action: DN See comments from Building permit #B06-011 Item: 05550 ENGINEERING CIVILS ********�**�******�*��*******************�******�*�**����*�*��**�****�*************************�*�*�**********�*********************�**��***�*** See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this stae and othe rordinances of he Town pplicable the eto des, design review approved, International Building and Residenrial Co REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF *��*�������*��������**�*���*�*�*�*����*��*�**����*�����*�*�*�***��*�*����������*�*�������*����*�*�*��*�* CONDITIONS OF APPROVAL Permit#: B06-0119 as of 04-20-2007 Status: ISSUED �x*�**�x*���*����x����x���:�=x:�*�x����x��x*�:��:���x�**�**�x*:x�:*����*���*����*�**�*=���=���*������**�:��*�x*�:*�:�x*�:*�*�*�x* Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: OS/10/2006 Applicant: R.A. NELSON & ASSOCIATES, INC Issued: 06/15/2006 Job Address: 4367 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR, Units 5&6 Parcel No: 210112305012 ��x�*�x*=�*�*�*���:���:���*:x*��:*���*��x*:�**�:*�x*�*��x*�x*�x�*:���x����*�*�*��*���x�*=x�x�x�*:����*:�*��x��*�:*�:��:���x�x�x�����x� CONDITIONS �*�*�*�x�x�x*�x*��x*�:*����x�*�:�x��x��:*�x�x��x*�:*��x��x��*��:*�x�����x��x��*�*�x�x:x�x��x����x��x*�x*�x*��x*�:���:��x*�*�x����*��*���x��:=� Cond: 33 (PLAN) THIS PROJECT PPROVED PRIOR TO REQUES OFOR A FRAME IN5P CT ON RVEY SHALL BE SUBMITTED AND A Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 39 (BLDG): EMERGENCY EST ON 0 SDOFETHE 2003IBCNGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SEC Cond: CON0008113 CONDITIONS OF APPROVAL: 1) GUARDS REQUIRED AT ALL WINDOW WELLS ADJACENT TO WALKING SURFACES AND PATIOS PER IRC R312 2) EGRESS WINDOW REDETAILn 0 A9.03SIS NOROO PR VED COMPLOETE FIREPLACEIRC R310 3) MASONRY FIREBOX SUBMITTAL REQUIRED WITH MECHANICAL PERMIT. 4) VERIFY ALL BASEMENT EGRESS WINDOWS PER IRC R310 BASEMENT LEVEL WINDOWS NOT SHOWN ON ELEVATIONS. Cond: CON0008126 Fire sprinkler system required and shall comply with NFPA 13R and VFES standards. Cond: CON0008127 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0008168 Prior to TCO, the applicant shall record with Eagle County and the Town of Vail language for a permanent easement to the Town for that portion of Lot 6 which is lcoated within the Town's right-of-way along Streamside Circle. Cond: CON0008169 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall comply with all restrictions specified by the Town of Vail Fire Department. Cond: CON0008170 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall record with Eagle County and the Town of Vail new plats for each of the lots which designate easements for both parking and cross access and an easement for the proposed dramage between Lots 7 and 8. TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Permit #: B06-0119 Project#: PRJ06-0007 Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL Applied . . : OS/10/2006 Location.....: 4367 STREAMSIDE CR Issued . . . 06/15/2006 Parcel No...: 210112213004 Expires.....: 12/12/2006 OWNER STREAMSIDE CIRCLE PARTNERSHI05/10/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DRAWER 5400 AVON Colorado 81620 License: 170-A CONTR.ACTOR R.A. NELSON & ASSOCIATES, IN05/10/2006 Phone: 970-949-5152 PO DRAWER 5400 AVON Colorado 81620 License: 170-A Desciption: NEW CONSTRUCTION OF A DUPLEX AND SITE IMPROVEMENTS TRILOGY UNITS 5 AND 6 Factor Sq Feet Valuation Occupancy T�e 9, 363 $1, 275, 611.00* Totals. . . Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,275,611.00 Revision Valuation: $0.00 **************************************�****************************** FEE SUMMARY***********************************+************�*********� $0.00 Total Calculated Fees-----> $12,324.10 Building------> $6,616.15 Restuarant Plan Review--> > $o.00 a,3 0 0.5 0 Recreation Fee------------> $1,4 04.4 5 Additional Fees------------> $12,3 2 4.10 Plan Check---> $ ) $12,324.10 Total Permit Fee-----------, $12,324.10 Investigation-> $o.0 o TOTAL FEES------------ payments------------------- Will Call-----> $3.00 BALANCE DUE---------> $o.o0 **********************************************************�************�*****************************�*********�***�*********�******��****�****** Approvals: Item: 05100 BUILDING DEPARTMENT Action: COND SEE COND 06/05/2006 cgunion Item: 05400 PLANNING DEPARTMENT Action: AP 06/14/2006 ee Item: 05600 FIRE DEPARTMENT 06/07/2006 JJR Action: COND See conditions. Item: 05500 PUBLIC WORKS Action: AP 06/09/2006 gc Item: 05550 ENGINEERING CIVILS *******************************************************************************�****�***y*�pp*y**************�*�*��*�******************�**** See the Conditions section of this Document for any conditions that ma a 1 to this permit. " DECLARATIONS I hereby acknowledge that I have read this application, filled ee to coml 1 ewi h the info mat n and p ot plan,�to complypwoth all and state that all the mformation as required is correct. I ag P Y Town ordinances and state laws, and to build this structur a othe rordinances of the Town ppl cable the et�es, design review approved, International Building and Residential Codes an REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4PM. SIGNA U OF O NER OR CONTRACTOR FOR HIMSELF AND OWNEF �*�*����*�**�������*��***�*�*�*������*�*��*����*���*��*���****�������*���������**�*����*��*�**���**����* CONDITIONS OF APPROVAL Status: ISSUED Permit#: B06-0119 as of 06-15-2006 *�x*�x�***�x*�x�**�x�*���x*�x*�x*�x****�:�x�*�*�*�x**�x�:x�x*���x*�*�x*���x*��x*�*�*:x�x�x��x*��x��x�*��x�*�*��x�x��x*��x��x*��x*�:�x��x*�� P/S,DUP) PERMIT Applied: OS/10/2006 Permit Type: NEW (SFR, Issued: 06/15/2006 Applicant: R.A. NELSON & ASSOCIATES, INC Job Address: 4337 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR Parcel No: 210112213004 *�����x�*�*�*�*�x��x��x�x***�:�x�***�:*���*�x*�x�*�x**�x�*��x�*����x�x**�x��*��***�*��x�x*�x�:�x���x����x�*���x*�x��x��x�:�x�:*���*�x� CONDITIONS �x��*�*��***�***�x�*�*�*�*�*�*�:x�*�x***�*��x*�x����x*�***�**�*�*�**���x��:�x�*�x*�x��x�*�x�*�x�x�:�x��x�*��:�*�*�x�x��x��x*�x*��x Cond: 33 (PLAN) THIS PROJECT WILL REQUIRER TO REQUEST�OR A FRAME INSPECT ON.RVEY SHAL BE SUBMITTED AND APPROVED PRIO Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANC . Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IR . Cond: 18 (BLDG.): STAIRWAYS ARE RBQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC O SECTION 1009 OF THE 2003 Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTIO 1012 OF THE 2003 IBC. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESHE��P IBC.GS ARE REQUIRED TO MEET SECTION R31 OF THE 2003 IRC OR SECTION 1025 OF T Cond: CON0008113 CONDITIONS OF APPROVAL: 1) GUARDS REQUIRED AT ALL WINDOW WELLS ADJACENT TO WALKING SURFACES AND PATI PER IRC R312 2) EGRESS WINDOW REQUIRED AT KIDSIBE oROOP R�VEDYCOMPLOETE FIREPLACEIRC R310 3) MASONRY FIREBOX DETAIL 10/A9.0 SUBMITTAL REQUIRED WITH MECHANICAL PERMIT. 4) VERIFY ALL BASEMENT EGRESS WINDOWS PER IRC R310 BASEMENT LEVEL WINDOWS NOT SHOWN ON ELEVATIONS. Cond: CON0008126 Fire sprinkler system required and shall comply with NFPA 13R and VFES standards. Cond: CON0008127 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0008168 Prior to TCO, the applicant shall record with Eagle County and the Town of Vail language for a permanent easement to the Town for that portion of Lot 6 which is lcoated within the Town's right-of-way along Streamside Circle. Cond: CON0008169 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall comply with all restrictions specified by the Town of Vail Fire Department. Cond: CON0008170 Prior to issuance of a Temporary Certificate of Occupancy by the Town of Vail, the applicant shall record with Eagle County and the Town of Vail new plats for each of the lots which designate easements for both parking and cross access and an easement for the proposed drainage between Lots 7 and 8. *******************************+*************************�***************************+****** TOWN OF VAIL, COLORADO Statement *******************************************************************:x*�******************+*** Statement Number: R060000809 Amount: $8,320.60 06/15/200601:37 PM Payment Method: Check Init: DDG Notation: check 1060 ----------------------------------------------------------------------------- Permit No: B06-0119 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR Total Fees: $12,324.10 This Payment: $8,320.60 Total ALL Pmts: $12,324.10 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 6,616.15 PF 00100003112300 PLAN CHECK FEES 297.00 RF 11100003112700 RECREATION FEES 1,404.45 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 ----------------------------------------------------------------------------- . . ,. _ � � -� APPLICATION WILL NOT BE ACCEPI"ED IF INCOMPL Projec #'SIG(�.(4(0. �y dd' ~) ��-���. Building Permit# � *: ,� ,. � � 970�79 2��9�,�lnspec#�c�t�s) � � � ��'���� � OWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact Person and Phone#'s: 47� -3 Z3l �,.�,0 _A �Z.V�-r5�-�-I NF�St-F� j�A NF�-�v� � Email address: �`(t�,TL��t� �' �'"��'� G� Fax#: g7p- ��-g - 4 3 7 Contractor Signatur : COMPLETE VALUATIONS FOR BUILDING PERMIT Labor 8� Materials BUILDING: $ �� ��7 9�� ELECTRICAL: $ �4� 5 �3 OTHER: $ 3�l 3(�O -5�'�w K-�-6Z PLUMBING: $ (oS'SCS MECHANICAL: $ 47� z-h 3 TOTAL: $ l Z 7S �� I For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea fe-count .com �ar�el`# Z/�/� Z��'Sa/2— Job Address: ���7 �-����G� c� Job Name: -r�f L.,�?�`{ '"U►.tC'�S ��p �/-.��L C� v Legal Description Lot: g Block: Filing: Subdivision: ,�31�r`�F �� d 3 �«s v� iS Phone: _ 47l-2`)t 9 Owners Nam : 5'C'��.� s�pE� Address: ��3��� � �� o av- �� i-+--�--� �..svr� 5-- Phone: Architect/Designer: Address: ��z.� � / �4�3 -�g� � ��� � c� So3oz �� - Engineer: ���jdU Address: /!zi �3 ��Y ��/ Ph n�e' _ � -��- nnL ot" �xrs'��i �� '1-�-�� C�'z`5%1z cz�'c� D�-_ Detailed description of work: p��-zo�-l� d. I�E�.�7 `rD�l-u. EE-Fic'G�_ Remodel Re air Demo( ) Other( ) Work Class: New� Addition ( ) � ) P � � Work Type: Interior( ) Exterior( ) Both (�Q Does an EHU exist at this location: Yes( ) No�C) Type of Bldg.: Single-family( ) Two-family(� Multi-family( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this buitding: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas LoDoes a F eoSpr nikler Sys em EBstnin Ye OTj LLN WEj Does a Fire Alarm Exist: Yes ( ) No( ) FOR OFFICE USE ONLY D T e of Cons�n��� Date Received: Occupancy;,Group ,..�._. . , ,��_ Accepted�By:� �AY 'J Z��6 � C�j i�' �u�� T17WN OF VAIL �� F:\cdev\FORMS\Permits\Building\buildi ng�ermit.DOC Page 1 of 16 02/09/2005 ******************************************************************************************** TOWN OF VAIL, COLORADO Statement *******************************************************�*****:x****************************** Statement Number: R060000552 Amount: $4, 003.50 05/10/200610:54 AM Payment Method: Check Init: JS Notation: 16920/R.A. NELSON ------------------------- Permit No: B06-0119 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR Total Fees: $10,919.65 This Payment: $4,003.50 Total ABalance: $6,916.15 ********************�**********************+*****�****************************************** ACCOUNT ITEM LIST: Account Code Description Current_Pmts --------------------------- PF 00100003112300 PLAN CHECK FEES 4,003.50 --------------------------------------------- ' << � Questions? Call the Building Team at 479-2325 � . ��?����,�, ' Buildin4 Permit Submittal Checklist Department of Community Development Project Name: ����� � V�� �� � Project Address• 43(�� ���"���� G� v'��— CO ✓ This Checklist must be comnleted before a Buildin4 Permit avolication is acceeted. � All pages of appiication is complete � Has DRB approval obtained (if required) Provide a copy of approval form � Plan Check Fee required at submitta)for projects valued over $100,000.00 (see attached fee schedule) � Complete site plan submitted � Public Way Permit application included if applicable (refer to Public Works checklist) �(, Staging plan included (refer to Public Works checklist) No dumpster,parkin4 or material storaQe allowed on roadwavs and shoulders without written aaaroval � Asbestos test and results submitted if demolition is occurring Architect stamp and signature (All Commercial and Multi family) � Full floor plans including building sections and elevations(3 sets for remodels, 4 sets of plans for SFR and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings) `� Window and door schedule � Full structural plans, including design criteria (i.e.loads) �( Structural Engineer stamp and signature on structura� plans (All Commercial and Multi Family) �, Soils Report must be submitted prior to footing inspection � tucLVVEfl '� Fire resistive assemblies specified and penetrations indicated ❑ Smoke detectors shown on plans - �o ' ��Qe�`'t P��c�7 1� B� ��8�`�� �, Types and quantity of fireplaces shown Applicant's Signature: Date of submittal: � Received By: F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 2 of 16 02/09/2005 ' ` � . i TnWN OF YAb ` ASBESTOS TESTING REQUIREMENTS TNE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITfED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITlON OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFfER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE DCEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION . I have included the asbestos test and report with my building permit application , app� nt sign tur date OR • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature date OR • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 4 of 16 02/09/2005 , � � � WHEN A"PUBLIC WAY PERMIT"IS REQUIRED �. ����� 1 PLEASE READ AND CHECK OFF EACH OF THE FOLLOWING QUESTIONS REGARDING THE NEED FOR A ��PUBLIC WAY PERMIT": o Is this a new residence? YES � NO o Does demolition work being performed require the use of the Right-of-Way, easements or public property? YES NO K o Is any utility work needed? YES�_NO o Are there any improvements being done to the driveway? YES '� NO o Is a different access needed to the site other than the existing driveway. ES 0 o Is any drainage work being done that affects the Right-of-Way, easements, or public property? YES � NO o Is a"Revocable Right-of-Way Permit"required? YES � ' NO_,� o Is the Right-of-Way, easements or public property to be used for staging, parking or fencing? YES NO X If answer it NO, is a parking, staging or fencing plan required by Public Works? YES_�_ NO If you have answered YES to any of these questions, a"Public Way Permit"must be obtained. "Public Way Permit"applications may be obtained at the Public Works office or at Community Development(a sample is attached). If you have any questions please call Leonard Sandoval in Public Works at 970-479-2198. I HAVE READ AND A SWERED ALL THE ABOVE QUESTIONS. � Contr or Signature Company Name Job or Project Name: � ``�`L�C� Date Signed: S�"'�o PRT#: - F:\cdev\FORMS\Permits\Building\building permit.DOC Page 7 of 16 , 1 . � DRAINAGE AND CULVERT INSPECTIONS ARE REQUIRED BY PUBLIC WORKS! Please read and check off each of the items below: • The Town of Vail Building Department has developed the following procedures to ensure that new construction sites have adequately established proper drainage from building sites along and adjacent to Town of Vail roads or streets. • The Town of Vail Public Works Department will be required to inspect and approve drainage adjacent to Town of Vail roads or streets and the installation of temporary or permanent culverts at access points from the road or street onto the construction site. Such approval must be obtained prior to any requests for inspection by the Town of Vail Building Department for footings, temporary electrical or any other inspection. Please call Leonard Sandoval at 970-479-2198 to request an inspection from the Public Works Department. Allow minimum of 24 hour notice. • Also, the Town of Vail Public Works Department will be approving all final drainage and culvert installation with resulting road patching as necessary. Such approval must be obtained prior to any Final Certificate of Occupancy issuance. Agreed to by: '�`'`���� C'�-'�/�`�z Print Name Signature Project Name: %_�`�=�'C'�/ Date Signed: ���� F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 10 of 16 02/09/2005 . �es�gn R+ev��w' Boa�d � AC'���?N FORt+� � Departre�ent af Cc�mmunitY i'�velo;prtoe�t ����� � 7�S�avk�Fro�ta9e�toad. VaiE, Calarado Si�� t8l; 97D.479.2139 fax: 970.�79.245Z r,r�,r,+����� v�e�:www.waifgovxar�e Project Narne: STREAMSIDE 4337 DRB Numl�: DRB060003 prp�t D�Stripti0�= � Construction of a new duplex; all specifications on file with 4327 Streamside Grcle,approved with 7 wnditlons Participants: OWIVER STRFAMSIDE C�RCLE PARTNERSHIpl/09/2006 3033 E i5T AVE STE 815 DENVER CO 80206 pppLYCqNT 57RFr4MSIDE CIRCLE PARTNERSHI01/09/Z006 3033 E 1ST AVE STE 815 DENVER CO 8Q20b Project Address: 4337 STREAMSIDE CR VAIL Locatior�: 4337 STREAMSIDE CR Lega� pesaiption: Lot: 7 9iock: Subdivision: BIGHORN 4TN ADDITION Parcel Number: 2101-122-1300-4 Comments: See 7 conditions of approval 8t3ARDJSTAFF ACTION Motion By; Dorward Action: APPROVED Second By. Hanton Vote: 5-0-� Date of,Approval� 03/25/2005 Conditions: Cond:8 (plAN): No Chdtlge5�o ttlese pl�ns mdy be m2de without the written conserct of Tovm of Vail staff and/or the appropriate review commitfiee(s). Cond: 0 (PIAN): DRB appraval does not mns�tuLe a permit for buitdtng. Ptease consuft with Town af Vail Building personnel prior to cans�cCion ac�ivities. Cond: Z01 DRB approvai sha[I not become valid Por 20 days followir�g the dabe af approval, Cond: 202 Approvat of this pro3ect shall lapse and becamE void on�(i)year tullowfng the date of flnal approval, unless a building permit is issued ar�d construction is commenced and is diligently pursued toward campletion. Cond: CON000789Z At the time of building permit submittal,the applicant sha(I provide an engineered mai-��-�v �i•�iam ri�m ivnn vi rniY VVIIpIVl�lii vrrrrv��r�.ni �����•..-.�r � ••� � ••�••�� � "' analysis based on AASHTO for sight stopping distances per t�e Town Code sight distance r+equirement of 250 feet. Gond: CON0007893 At the time of building permit subrnf�tal,the applicant shafl provide a site plan which Indicates a parking tum-around at the eastem edge of Lot 8 which complies with the twel�e f4et(iz`)width �equirement specified in Title 14: Development St�ntlards Handbook. Cond:CONQ007894 At the time of building permit submfttal,the applipnt shail provide a landscape p�h whiCh designates that afl existing or proposed landsc,aping�lon9 the Streamside Grcle right-of-way will be trimmed up ta seven feet(7')-in height and all existing or proposed fandscaping w'sth l9mbs overhanging the S7eamside Grcle right-of-way sha[I be trimmed up to eleven fe�t(li') in heigh� Cond:CON0007895 Prior to rei�se of the building permit by the Town of Vail,the appiicdnt shait submtt a revocabl�right-�f-way permit for each IoC for approvat by the Town to allow for the praposed landscaping to be i�ted a(ong the northem edge(Bighom Road right-af-way)of the development site, Cond: CON0007896 Pnor to refease of the building permit by the Town of Vail,the appiicant shall record with Eagle County and the Tovm of Vall language for a permanerit easemerrt to the Town for that portion of Lot 6 which is focated within the Town's ri�ht-of-way along Streamside Grcie. Cond: CON0007897 Prior to issuance of a Temporary Certifcate of Occupancy by the Town of Vail,the applicarit shall record w�th Eagle CouMy and the Tc�wn of Vail new pl�ts fc�r each of the lots which designate easement5 for both parki�g and cross ao�ss and an easement for the proposed drainage between bts 7 and 8. Cond; CON0007898 Prior to issuance of a Temporary Certificate of Ckarpancy by the Town of Vail,the applic�arrt shal!comply with all restrictions specified by the Town af vail Fire pepartment. Planner: Elisabeth Ecke1 DRB Fee Paid: $650.00 1 '� . 1 ` . 1 1 . � / / � -- 1 -�- . 1 1 1 . 1 � 1 1 1 1 � ASBESTOS ASSESSMENT SURVEY 1 EAST VAIL VAIL, CO ► HOUSE ONE, TWO, AND THREE 1 Presented to �� Jeff Peterson ► 1 March 11, 2006 1 1 1 I 1 1 I I 1 \� PREFACE � Commoniy used Asbestos Related Acronyms ACBM Asbestos-Containing Building Materials ACM Asbestos-Containing Materials AHERA Asbestos Hazard Emergency Response Act HA Homogeneous Area HEPA High Efficiency Particulate Air LEA Local Education Agency NESHAP National Emission Standards for Hazardous Air Pollutants � O&M Operations & Maintenance PCM Phase Contrast Microscopy PLM Polarized Light Microscopy TEM Transmission Electron Microscopy TSI Thermal System Insulation ,�� ► � I, introduction � � An asbestos assessment survey was conducted by James E. Stout for Jeff Peterson. Mr. Stout is the Field Representative, EPA accreditation # 4757. The purpose of the survey was to locate, sample, and assess suspect asbestos containing materials (ACM). II. Structural Design "� The facilities are two three-story houses, wood and sheet rock construction. 111. Sampling and Analytical Procedures Random bulk samples, representative of the suspect asbestos-containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is base on the following criteria: I. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. `�; 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if: 1. They exhibit similar physical characteristics. 2. The application of the sampled material can be correlated to the application of unsampled material. Bulk samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July,1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Bulk samples we�e collected on March 2, 2006. Analysis of the bulk samples was performed on the "date reported", as listed in the bulk sample analysis report. Condition assessments were performed by the accredited inspector at the time of inspection. Samples were analyzed by Reservoirs Environmental Services, Inc. (Reservoirs). Reservoirs is accredi#ed by the NVIAP (Lap Code 1896) and participates in the NVLAP � and AIHA Bulk Asbestos Sample Quality Assurance Programs. � IV. Notes on Report Format ' Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: I. Surfacing material: sprayed or troweled onto structural building member. - � 2. Thermal systems insulation: any type of pipe, boiler, tank, or insula#ion. 3. Miscellaneous: other suspect materials, including flooring, ceiling tiles, insulation, and finishing materials. HAs found to contain asbestos are described in the following section. Diagrammatic floor plans showing approximate sample locations of these areas were not available. Condition assessments and response action recommendations for asbestos containing HAs are also in the following section. Recommendations may be for more than one HA, if materials are alike. • Recommendations are either "general" or "immediate". Immediate recommendations indicate imminent hazard and should be addressed as soon as possible. ''�,, V. Inspector Comments The following is a summary of the types of asbestos-containing materials found at houses #1, #2, and #3: House #1 and #2 has sprayed plaster siding. INSPECTOR COMMENTS: Houses #1, #2, and #3 are scheduled to be demolished. All friable materials (surfacing) MUST be removed prior to demolition following Federal and State Regulation (Reg 8). House #3, no asbestos detected. VI. Asbestos-Containing Homogeneous Area Descriptions and Sample ' Locations The following pages contain asbestos containing HA descriptions and sample location. Percent asbestos content for each sample indicated can vary depending upon sample locations, homogeneity of the materials, and type of application. � Homogeneous Area 01 outside plaster . Material Description: plaster � nnatPrial l,ocation Material Condition __ outside house#1 and #2 poor _ Sam�le# L i n ��r �osition B101-03 outside plaster 4% Ch .rysotile Immediate Recommendation: The surfacing material is in good condition with potential for damage. Implement perventative measures to lessen the possiblity of fiber release due to building occupant maintenance activity. Examples are to avoid touching or striking surfaces. �If the material is to be disturbed, ensure that only personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA-filtered vacuuming, wet cleaning methods, respiratory protective clothing, personnel decomtamination, mini-enclosures). General Recommendations� ''' �, Maintain material in an undamaged condition. Properly maintained asbesto-containing surfacing material poses minima! risk of fiber release. Visual inspections of the material should be conducted biannually by employees trained in asbestos control. This will enable the building owner to continually monitor and assess the condition of ACM and assign proper response actions when necessary. � ' � , . � ( Homogeneous Area 01 spray -on ceiling in House #1 �� ► Material Description: white surfacing material I � Material Location Material Condition _ above closet in living room good, potential for damage _ ' above closet in south bedroom � � � Sam I�e # Lo i n Composition B101-01, B101-02, and House #1 4% Ch .rysotile ' B101-03 � Immediate Recommendation: ' The surfacing material is in good condition with potential for damage. Implement perventative measures to lessen the possiblity of fiber release due to building occupant maintenance activity. Examples are to avoid touching or striking surfaces. If the material is to be disturbed, ensure that only personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA-filtered vacuuming, wet cleaning methods, respiratory protective clothing, personnel decomtamination, mini-enclosures). General Recommendations: � Maintain material in an undamaged condition. P�operly maintained asbesto-containing surfacing material poses minimal risk of fiber release. Visual inspections of the material should be conducted biannually by employees trained in asbestos control. This will enable the building owner to continually monitor and assess the condition of ACM and assign proper response actions when necessary. �� I � I I � Homogeneous Area 01 spray -on ceiling in House#2 � � Material Description: white surfacing material � � Material Location Material Condition _ � above front door good, potential for damage � hallway " Sample# Location Composition 6201-01, B201-02 House #2 4% Ch .rysotile Immediate Recommendation: The surfacing material is in good condition with potential for damage. Implement perventative measures to lessen the possiblity of fiber release due to building occupant maintenance activity. Examples are to avoid touching or striking surfaces. If the material is to be disturbed, ensure that only personnel trained in the handling of ACM be allowed to conduct such activities using appropriate methods (HEPA-filtered vacuuming, wet cleaning methods, respiratory protective clothing, personnel decomtamination, mini-enclosures). General Recommendations� GMaintain material in an undamaged condition. Properly maintained asbesto-containing surfacing material poses minimal risk of fiber release. Visual inspections of the material should be conducted biannually by employees trained in asbestos control. This will enable the building owner to continually monitor and assess the condition of ACM and assign proper response actions when necessary. �f I � � { • . �! � ( � - ' . � 1 1 ! .APPENDIX CERTIFICATES ~� � } t r1 "� i �` 1 .� � ,1 '' = � � -i1 -'� �f � I � r '� � � + ..t � � ' ' �t I� �-� � ',` ' 1 i ��Iy ` 1 •1�\� l/ �' . \ '..��.� .l 1���� ' , , �� ' �, r'` ,. .i - � :..:i ��.�... ��1,� , , .� i. . �� .� . i �li�I \ �:r:�� 5 E R V I � E ,S I N G 14367 Lakeview Lane, Broomfleld,Colorado 80020 Tel: 303.424.4647 Fax: 303.432.8669 CERTIFIES THAT JIIV! ST�l1T Has successfuily cornpieted The EPA-Approved AHERA Annual Refresher Course for INSPECTOR/MANAGEMENT PLANNER . This course is EPA-approved under Sec#ion 206 of the Toxic Substances Controi Act (TSCA) and meets fhe requirements of Colorado Regulation No. 8. Course Date: 1i19l06 � �v Exam Date: N/A r%' ° Ce�tificate No.: AE06-002-BI/MP-R-06 r�,��/��.��,'�,)��.. .�—� Expiration Date: 1h9107 � K. Jay Gale, Pr¢sident J �,: M�,y � C;�: 06 OS: 40p DS Consulting, Inc. � Clnmatched Credentials.Superior Results: May 8, 2006 East Vail House #1 —Lot 6 Inside spray-or► cei�ing 1�floor 1,097 ft.z 2�fl�r 500 ft.2 Basement 144 ft•2 putside plaster 1,890 ft.2 House #2—Lot 7 A�ter further testing, no ACM is present N���� �3 — Lot 8 No ACM is present. Sincerely, I�, ._..�:'��--- .�.^/;%. � v ]II'Yl StOIJt project Manager DS Consuiting, Inc. 303-882-5271 ce11 303-279-6942 home .._ .�t... . .-. ..�..� .-.t ,. �� .:. . .. . .;.:���, ^... ,..�...-.,_ �. . ...,..i.r'�-• -_ _... .. _. .. _ .._r''^... . . DS Consulting, Inc. � DAI LY AIR SAMPLING utunatck,ed creaeneals.svperio�ttesults. Pro'ect Contaat: Jeff Kni ht Caliected by: Jim Stout Date: 4/26/2006 Client:H&A pCM Mal sl: Jim S1out LocaGon:House#1 in Vail 7EM Fiiter. .fob#:0009 pCM Filter: Microscope fie{�area: M�g,_<0.45um 25mm Mft_,. 0 00785mm' X,_.0.8um 25mm Mft PC_<0.45um 37mm Lot# Means of pump ca�ibraGon: Filier ECA: p.sum 37mm Lot# Gilien Gilibralor#�— X 385mms X— � mm= Calibrated Rotometer# X_ mm' Air Volume F6rs. 5ample Liters Fids. LOQ Fbet�s/cc D��p�N Sto : Avera e Sample# �a���_ ��� ; �rt: Slo Total Minutes: Start: - _ Pum � T B� _ . - ' Average: _ - - 0l100 Fletd Blank - _ - H&A 01 _ _ _ . Fieid Biank ' HgA 02 1100 3/100 0.004 <LOQ upper levef SE ��p 10 i0 10 gpp 950 H&A 03 IWA bedroom door �� <�,OQ upper level at �0 10 10 '1100 ZI1U0 O.OU4 800 950 110 ��q door to deck �� <LOQ Hg,q pq �� �pgp 4I100 0.004 towerlevel 953 108 �� �� WC livin CL 805 HB�A 05 �WA <LOQ front halt 9.8 9.8 9.8 1100 3/100 0.004 CL 805 955 110 H� �s �Wp bedraom ��pq N at boriom ,,,,� oaF 110 9.8 9.8 g.g 1100 21100 4.004 Pfease use reverse side ot farm for sampling location map. Please fil out a CHAiN OF CUSTODY if sending samp�es to the Iaboratory. SAMPLETYPE: P=Personai IWA=inside wo�C area OSWA=outside worlc area Kev to ahbreviallons: HEX=HEPA exhauat g=background a,c-nvirr: REM=removal CU=ciean up GB=91ove bag B!O=bag out PREP=work site prepat�stion - 3 b� C� � � 0 m 0 m k 0 -a DAILY A!R SAMPLING � hluds eth and Assocaites Inc. DS Consulting, Inc. � Unmatched CredenHals.Superiar Results. Pro' ct Contac�: Jetf Kni ht Cp�{�ted by: Jim Sfout Date: 5/4I2006 ,Ifent pCM Ma t: Jim Siou! Location: House#1 in Va+l TEM Fllter: !ob#: 0009 PCM Filter; M��_�p.q�um 25n,m Mft Microscope field area: 0.8um 25mm Mit <p.45um 37mm Lo� .�,,,..�.,�numn cellbiafio�: Fitler ECA: _ x 0.00785mm' x"�'n a��m 37mm LOl# PC lease use reve�se side of fortn for sampling localion map. lease fill out a CHAtN OF CUSTODY sendi�g samp�es to the laburatory. SAMPLE TYPE: P=PB�Onai IWA=inside woric area OSWA=outside worlc area HEX=HEPA exhaust B=badcground ACTIVITY: REM=temavel CU=dean up GB=91ove ba9 B/O=bag out PREP=wrork sile preparelion 3 °L CS. u C0 0 fn 0 m -P O � r�ut �4 _�/2006 07:10 3037915780 HUU�PETH Colorado Department ofi Public Wealfih �and �►?ndoo Am unt Air Pollution Control Divis�on —Stationary Sources Pr g 4300 Cherry Creek Drive South, APCp-SS-B1 Denwer, Coloradv 80246-1 b30 Phone: 303-692-3100— Fax: 303-782-0278 E-maii: asbestosQstate.co.us TIO� APPRO�,A►L NU'�ICE DEII�OLI uali Control Commissxon T1iis approval notice Xs g�ranted subjECt to Co�orado A�ir Q t5' �005 ��� Regulation No. 8, Paxt B, adopted Decei�b�x 16, 2003, ax�d �f.f.ective March 2, � ir Po�lutionPrevent�oza�and.Contro].�:��C.�.S. (25-7-a.0� aa�.d 25-?���Et seq). Colorado A `l,'l,�i.s notice sign�f.tes tb.at the strr�c�ture was inspected�ox asbe a��an� o£�ubl c Health and demolition contx'actor has pxop�rlY r�otifaed tk�e Co�orado Dep Enviranr,�.�nt pursuant to �egulation No. 8, �'axt B• depending on As a con�'actor, �ou may be subject to o�Chex de�olition licens�o�s���g Perforrned: The the requ�r�z�nents of the couxity and municipa���o�����lr pollu�iox�Cont�'ol Division, Colorado Department of Publxc H�alt11 and E ��Qtt a su gests that yau check with county and rnunici�al authoust be in.e aer to g � � erimitting requ�xem.ez�ts that m d�termine ar�y oth�x' loca1 buildingl� . OgIGINAL PE��� NIUST SE P�S'��� ON SITE AT A�I-L '�`I�"►ZES. ��� . ax nu�nber above) or�-►nail(addwess above) ur�d Immediately �xot�;�'j�the Unit of project modiftcc�Eions bY.f ( the ap,prvp riate reur�ty he+alt� depa�tine�xt 6y,f'ax. ProJect modifcations includ�charages in fhe scope of work or!he schedulcd work dates, etr. �1;59�'M�m 5/10/2006. This demalition not�ce is�1'i�,d l�e�a�S������512�006 through 5l�,UI2006. The actua� s�k�edul AmouxttPaid: �$S.QQ Appraval.xssued on: 4/20/200G Check number: 08�25 Record number: �1128 Aabestos Building Inspectox: 1�1oti�ce Number: 06�.A.2281D Tames�.Stout �or the loca�ion speczfted below: C�ifcation No-: 4757 Single k'str�aly Home � . Ins�ec�ion Date: 04/18/2006 4367 Streamside Cir V'aii Eaglc County This noticc has been issued to: Issued by: Hudspeth & Assoc�ates,Ync. `� 14 Inr�erncss A�•, c. Ste.F-124 _ _-- Englew��d,CO 801.12 EA Inc. B Consulting Structural Engineers March 2, 2007 Job#05431 , � . � . A .:. / ..~1 Will Hentschel � :�'a Oz Architecture � 1820 Folsom St �� Boulder, CO 80302 Re: Lot 8 Stream Side Vail—Units#5 &6 Framing Observation Dear Will, Based upon initial and follow up observations of the wood framing elements of the subject duplex structure conducted by a representative of our office, and exceptions and comments made to the field superintendent,it is our opinion these elements were installed in general conformance with construction documents prepared by our office. We include specific response to items referenced by the City of Vail Building Inspection Report dated January 3, 2007 as follows (numeration per report): 1) Of the three glu lams installed inverted, only one requires augmentation in accordance with the detail provided. 2) Roof framing revisions in the master bath were reviewed as installed and found to be in general conformance to revised framing configurations provided. 3) We understand full bearing in hangers referenced was accomplished by the contractor. 4) We reviewed 5'/2"LVL lookout framing at master closet area of Unit 6 as well as other areas revised from the submitted permit documents and found them to be in general conformance with revised configurations provided by our office. 5) Holes drilled in microlams at various locations in both units appeared to be in accordance with recommendations provided by our office. 6) Revised framing of stud/header groups at the tall window walls adjoining the great rooms of both units appeared in general conformance with adjustments approved by our office during the course of construction, ar otherwise assessed as structurally adequate. Please call if you have any questions regarding this information. Sincerely, - GEBAU, INC. �' - , ��°��� ; : � . � _ ,� . John Arndt,P.E. ��� . � `= `� JA/rd Cc: Eric Norton, R.A.Nelson � 1 1 Z 1 Broadway, Suite#Z01 ■ Boulder, Colorado 8030Z ■ (303) 444-8545 • Fax (303� 444-3140 Mar 05 2007 4: 40PM Gebau, Inc. 303-444-314� p' 1 . 6A � tnt. G E ` � Consulang.Structural Eng�neers Client � ��• � '� Job #� � � Date ' � � + �, Design by.���ht.�of � Project 'a,�r'ra�''d�''�`�'i'r� �` . . " � ��rt; .�.�!���X/•2 C,tt�G'�'N!. '` l�ll�l'4-��1.�i���'+�`�' . ..._. . �. _ .. . � . . � . , . ; . . . . . � . , . ; . , . : , . . ., , . . � . _ . _. . _, . . . .. , .. . � . � � ...:�..: ... .. .. . � : � , ,.: . . . . . , . _ . . . i .�: . ... . .... . . , . ... . . - , . r, . ,. . . 'f". ��",� �' p �..� .. .. : ._.. �.,. ... .. e1 , � . , � : . . � �, �r+ ' . . . � � � �� � � ��� � . � . .. __ _.__.__ _.���� . �� � _ . � . . . , . �. . :; .,, . � . . : * ���-,,�.� �, ,qp�.. �.:..� ��.��X�� �.co.�I'T. d��, .. . . . . . � : . . .. �:�' ��'"��11L .�iC� . . , , . . . . . ,:; � . 2-1�� i✓.�� . . o���r � .,� . . , .. �� ���.r� �� , . . . m�� ����r,�: � . � . . . . . .� � . .�' �;�,�� ,� � . � � , � . . . �. . . : , . . . . . . �� �- � � . , . . _. . . . . . . ... . . . . . . . . .: . .. , ., _. .. . . . . . , . _ ._ . , . , . . . . . . . , .� . _ , ��, - - . � . ... .. : ��� , :. . ._ _:��t�-r �' ���� . . _ .. __ . __ ___ _ __ . _ . . . . . _ ���- . . , . �. . . : . . . , . . , . ..._. ....___ . . . _ _ _ .... .:_, . _...._�. .. . . . . , ... . . . . . .. ,. : : : : . : .: � _ : . _. .- , . � ., . . , . � . . .. . _ . _ :� . _. . . . ... ... ., . .,... ...._. ._ r..,� . . . . . . __ ,..... . ;. .:. . . _. _ _ , . . ._.. . : .. . . _ . . .. . . . . .,. :..: . . . , . . . .. . . . . . . . . . . � , . . . . . : . � .. . _. _ _ . . . . ; . . _ _ __ _ , . . _ . . . . . . . : _ . . , . . . _ _ �,. . „ � . . . . _..t__...�.�_..�_.� . . . . :......r.,._. .��. . . . . Y.. , .. , . . ... i..c,' . , �� . ;... • ' , , . ,r_. , . . .� r : �.�:.. . . . •' . . . . . . . .�.:; . � . . •. . . �, .. � . . . .. . . ..... . :.. . .. � . . . .;;:. -.� ..��� It�°�'"`� �.::...:.T. :.,� . .. ...: :. , ., . _ . . .. .. .._.:.:�..,._,_..._.:.,�.:_.:�.-:..,,....:..: . . . . . ..... ... _. .. � . .. � , . .. , . :: - : �. ;.. ...�., :.�: , . , ..w�`,:" ...,� . , . ' �.. .,,. . , . �.� . . . . , . ..:... ; v Q� � •► ,p�r� ., „ . .. , . . : .. . �� � ,;, � ... .-... . . :. �. . ._, ,...,:. . • L"Q."� �',��� ' : ;...:.. :. . .....,•,.... ... -.:,.• . . , R ; v� � !� . :,...,., . � � . . ' � ' ' �. . ;. � :. �' . .. *; '. �w*; ..,, . � .. .. . . . . . . • .. - - . , . : , „ . . , . . ... . � ., ,.:._ .:.. •.';..,._ .. �'�►�.i . .; . ... _ ..:.: . ...�..'.• r ' • •.. ' . . . . . . _ .. t , � . l�j>, ,IA�� � � 7 �:��-! __. ..__.._._. . ._.. • ��fV.r �l�i��"' �+��w��x"�°' . .r � � . �• . ,�i�'��600����°°�'���. .. ... . . • •. . �.'r�CJ1rPl4 ��a��'� • . . . �.�a�� 303 444-8545 Fax(303)4449140 1 12I Bro�dvvay,Suite 201 Boulder, Eolorado 80302 l 1 Mar 09 z007 8: 14RM Gebau, Inc. 303-444-314Q p' 1 � , InC. . . � Consu�ting Structurat �nglneers � ' Job#45431 � ?vtareh 2;2007 Wil�Hentscbol . , . � � Oz Architccture , � , 182Q Falsarn St . • . , Boulder,C4 80302 � , . � . R�: Lot 8 Stream Side V9►�i—Units#S p ment'��amin�Review ' Framtng Observ�adon&Strnctural Respaaee to Hmildin8 eps� �,:,, Deax Will. Based upon irritial at�d follorov up obs�'v�tioa�e officc sud�a`AUd c�arnmYent� umade to the�ield struct�ae eonductod bY a rcpresentatave of rnir o , �P auperintcndent,it is our opinian the�e el�mtnts wcrC installed in general eonformance with canstruetian� artd b aur office. We inelude�peci.fic response ta iterns refercnad 6y the Ci4y of Vail dacurncnts.preP Y Building Inspection Report dated March S,2fl�7 a�fvllows.(nuinoratian per reporz)' . � lj The Narthwest wa�1 of the gteat room adja�tnt the regr entry wa$desi�Cw of c constnrction docurn�nts as a 2ac 16 wa11 and in�talled ae�15� conditiona indicatzs only 2��6 was required swch that the w�11 ahould be siructurallY adequate a�inste►lled, over tha master bath alang Grid • Z� p 51/s"�12 GLU lam beam was specified in the mof framing A.4. '�aee 7y." Lvr�s were ac�y�� ��aw of the�nstalled member:►na�cst�s ate ta s�fel deaiga snow loads such that no Further they should be etruci�ally adequ Y�FI�� remediation wi11 be required. roof aver the ldtchea wes 3) The designated 8x8 column at the Northeast co�na vf the high gx�e ade uatel installed as 6-ZxB. This�lwuld be struciurally accaP►t�ble pra�rided they , q Y S�S. nailcd ar bolted. 4) A tYuec 2x10 flush besrn projecting lmdezVL�wt'tht�tx G�US 2COnnr.Ction.�T o LS9 clips apecified to be flush framcd to e 2 11/s L may b�substttuted far this member with full ldn naiiing,an�each side of the 3-2x1 Q. Please call if you hava any 9uesti°��6��ng���0��on, . Sincerely. • ���`��'.� � GE�AU,Il�tC. �� � .. •-., ,�'`�`c� ' • .�'. � i*! , 1$� �*K � v # °a� 4 or a xo�m Azadk P.E. *;�'� •„ �;�+,�A'� . SA/rd ������•....••'���t° . •w����l�,'� � � Cc: Eric N�a�toa,1�..A.Nelson . 303f 444-8545� • Fax (3Q3J 444-3140 � �z�, s�� Suioe#�O1 • Boulder, Cd4rado 8030� ' � . � Torzetto aka Trilogy aka Streamside Circle Partnership Lots 6, 7, 8, Bi9horn Sub, 4th Addition Lot 6, 4327 Streamside Cir West, Parcel 2101 122 13 003, Units 1 & 2 PRJ06-0008 B06-0117 A07-0009, UNIT 1 A07-0010, U N IT 2 E06-0129 M06-0156, radiant heat P06-0084 Lot 7, 4337 Streamside Cir West, Parcel 2101 122 13 004, Units 3 & 4 PRJ05-0557 B06-0118 A07-0007, UNIT 3 A07-0008, U N IT 4 E06-0131 M06-0155, radiant heat P06-00082 Lot 8, 4367 Streamside Cir West, Parcel 2101 123 05 012, Units 5 & 6 PRJ06-0007 B06-0119 A06-0106, UNIT 5 A06-0107, UNIT 6 E06-0130 M06-0154, radiant heat M07-0013, fireplaces P06-0083 , ,� � ���� ��� � ��� � � �� . �.�.��.���.�.-.�...�: `� � a+�t�t�d#�D��ev��tikt�m�m �. � � �P[��elakionships Ox�er#�s���i��� j � �— ; s ACTIVE D��: 05l1Ul�UOfi � � ��m���DEV�fi-ODU� St�tus. �� ,�'DE11t16-�Q� ; �l��e: DEV � �ub Typ�: j o ' RRJa6-���07 �: , . � � Ti�le: TRILOGY : = A��-01�� ' , } d '�ele�t � La�ak�n: 43�7.433��43fi�STREAM5IDE CR ' g � A�-�1�? ' �act�ity ; ��._ � d �Ofi•�11� �ele�kA11 Relat�d ta P"toie�t ` D DU�►T�001 � Q DRB���(I�� , ����� ��� P�u��PRJO6-OOUB����:ACTIVE ��at� 011091�OOfi : � URB�15� ������� ���'�� � � ��� C9�a�BD7�4���� Typ��PROJ ,Su��� _ � �� � d E�16-011� � �'r�:t��s title: STREAMSIDE CIR BLDGS 1�2 ,_� � � Ep�_p1�D �� ���`�`'T,;'; ' Loc�ion: 43�7 STREAMSIDE CR � D MQG_�15� , ? � �� ,�� ; R�mau��ramPraj � � �0��01 ' �,.>}°,�.�c ` �el��t tde�Pt4j ; � � �'�-�$� � ; � � � �� ��� � � �� �R3as-aoa� ���-���� ; �o�,�������������Tn����� ��� � � �� � x �-~'$k�;�.,°�-�.� �1 � � �s�'t ��� ' , ;� ��t 1�1 �i�le ; , AC11'�E �� � �:�t�=,� P f�.� ���� .�.�..�_ ������ §,�T e:�~~-.� � �Sub T �:~� � !` PFi�� �� � ' ���� � � � �i _...�� ��,�'�,�t�fr� f { w� � ��. � ..:.��s ; ��Titi�,-�-�..� �� .�.�_� �_ �� � � �= STREA�151�E CR P�TNE�5H1P� ,--P�itnarU�lame �F '�� �. _"� T�ee�lect _.; ¢��TRE�M�I�E�1��1.E PA�Th�E�NIP� E � 4� .......,..� � �' �� � �' � � �� ��'�o�.De�� 'or� ��� � ., NQwSet F,��rc�a��€��E �t �� � 8ack E�ik ' �i CONCEPTUAL REUIEW F�R A �� NEWDUPLEXAND5ITE � + � -�.,�.�.-.�°-.�`.-�'=...�`�"`"1 �IMPRaUEMENTS � ' BaGk�tQp � � �A T�al�ar�r�der , � �; i � , ; i �� i) � I � 43 �.1 1 i �� � , , :. � �,..,..�..,. w....,..�„�«,..��,._�:..�,,,.«a. TOWN OF VAIL FIRE DEPARTM��iT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL;CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIME ALARM PERMIT Permit #: A06-0106 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL �,pplied . . : 11/17/2006 Location.....: 4367 STREAMSIDE CR, Unit 5 Issued . . . O1/08/2007 Parcel No...: 210112305012 Expires . .: 07/07/2007 Project No : OWNER STREAMSIDE CIRCLE PARTNERSHIII/17/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT SUPERIOR ALAKM AND ELECTRONIII/17/2006 Phone: 970-926-8'188 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 CONTR.ACTOR SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-8�88 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 Desciption: INSTALLATION OF A NEW MONITORED FIRE ALARM SYSTEM Valuation: $3,700.00 *******************************************�****�****************�** FEE SUMMARY ******�***x:******************************************�***:�** Total Calculated Fees--> $3 7 0.7 5 Elecaical---------> $o.0 0 $0.0 0 $0.0 0 Additional Fees----------> $3�0.7 5 DRB Fee---------> $p,oo Total Permit Fee--------> Investigation----> $3 7 0.7 5 $0.0 o Payments------------------> $p.0 0 Will Call---------> BALANCE DUE--------> TOTAL FEES--> $370.75 ********�***�**���*�**�**�:************��***************************�:*�:*��****�*:�**�********�:*�:*�***��****�*�:***:�***�**************************** Approvals: Item: 05600 FIRE DEPARTMENT 11/17/2006 McGee Action: DN Insufficient coverage. Does not meet minimum VFESActionarAP field changes as required for outside 01/05/2007 mvaughan bedroom coverage ***�****�************************�**�*�******************�****�*�***NS OF APPROVAL******�**********�******�******************�****** CONDITIO *�***�*�************************�***************�*�********************�**ATIONS*********�**�:*******�********************�*******�***�****** DECLAR knowled e that I have read this application, filled out in full the informatioheenformarion and plot planutotcomply I hereby ac S plan, and state that all the information as required is correct. I agree to comply wi with all Town ordinances and state laws, and to build this structure accord'i dinan es of the Town a pli ab elVthe�e oodes, design review approved, International Building and Residential Codes and other o REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL FIRE DEPARTM�NT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIME ALARM PERMIT Permit #: A06-0106 '�(p— O«`t Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL �, lied . . : 11/17/2006 Location.....: 4337 STREAMSIDE CR-TRILOGY #5 Ip ued . . . O1/08/2007 Parcel No...: 210112213004 Expires . .: 07/07/2007 Project No : —�,�-�(�CQ �C��� � OWNER STREAMSIDE CIRCLE PARTNERSHIII/17/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-878 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 CONTR.ACTOR SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-8788 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 Desciption: INSTALLATION OF A NEW MONITORED FIRE ALARM SYSTEM Valuation: $3,700.00 ********************�******�****�**�*******************�********�:*** FEE SUMMARY **********�******�***********�***�*********�***�************ Total Calculated Fees--> $3�o.7 5 Electrical---------> $o.0 0 $0.o 0 $0.0 0 Additional Fees--------> 3 7 0.7 5 DRB Fee--------> Total Percnit Fee--------> $ Investigation----> $0.00 � $370.75 $0.0 0 Payments------------------ $0.0 0 Will Call--------> BALANCE DUE-------> TOTAL FEES--> $370.75 *****�****�************�****��*******�*�******�******�******�******�**�:*�**�**��**********�**�****�:*************�***�***�****�***�*******�***:x� Approvals: Item: 05600 FIRE DEPARTMENT 11/17/2006 McGee Action: DN Insufficient coverage. Does not meet minimum VFES standards. O1/05/2007 mvaughan Action• AP field changes as required for outside bedroom coverage *****�***�**��**********�:****�**�*�********�*******�**�:�****�**�****NS OF APPROVAL�*��********�**************�*********�******��***** CONDITIO �*�***�*�**�***�**�*******��**��*******************�*�**************LARATIONS***�*************�*�**********************�*********�******* DEC I hereby acknowledge that I have read this application, filled out in �totcom lorma���enformation and plot planutotcomply plan, and state that all the information as required is correct. I agre P Y with all Town ordinances and state laws, and to build this structure a�her o dinances of the Town ppli ab el the etoodes, design review approved, International Building and Residential Codes and o REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS I VANCE BY � P ONE AT 9- 1 F OM 8:00 AM-5 PM. SIGNATURE OF OWNER OR CONTRACTO FOR HIMSELF AND OWNEF ***************************���************�*********************�**********�**�********Statement � TOWN OF VAIL, COLORADO �x:x�*�x�x�x*******�*:x�x***�***�********�******�********�:******�***�x******�x*�x�**�x�x��x*********�x��x�x* Statement Number: R070000019 Amount: $370.75 Ol/08/InOt08DDG � Payment Method: Check Notation: Superior Alarm 3854 - Permit No: A06-0106 TYPe: ALARM PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4337 STREAMSIDE CR-TRILOGY #5 Total Fees: $370.75 This Payment: $370.75 Total ALL Pmts: $370.75 Balance: $0.00 ******�x**�******�***�x*************�*�***�x**********�*********�x**�**�***********************� ACCOIJNT ITEM LIST: Current Pmts Account Code Description ____________ ------------ -------------------- ------ 138.75 BP 00100003111100 FIRE ALARM PERMIT FEES 232,00 PF 00100003112300 PLAN CHECK FEES ------------------------- � t {._E� -1�� i i'j , ° / D � - ��;� .., ppP CA7ION WILI N07 BE A�CE�T U��YN�OMPL�E�T�O��N �w � i �: ] —`-�--�------�;ti-';�,`,�j� � � Buiidi�r� Permit#: � ` , Alarm F�ermit #: � � f`� � - ��'�, � �-�� ` ;, fO�WN OF VAIL FIRE p►L-p►RM PERMIT AF�PLICATION 't�?INN OF VAIL ' Commercial &Residential Fire Alarm shoR drawings are required at time af 75 5. Frontage Rd. ap�lication s�al�mittal and must incl�de infarmat�on IiSte�i on the Vail, Colorado i31657 2" page of this form. ApPf�catian will not be acceptecl rwithout this information. COPiTRACTOIZ INFOt�.�lATI�N Fire AI3rm Contractor: Tc�wn of Vail Reg. No.: Contact Person and Phone #'s: � �� � , � �L G c' (__(� I;t i �,,'C C�L-C.0 �� r � �' j 5�,��'-'-��'"j� f�'���t���}'l ` ��-��:� -i 3" ( - � � � �U ��l. '�2 i.'`�' Gd-.�L�.f'i-7��`� •��`NY�.Fax#• � �@ � 7��� �! E-Mail Address: ( (,�,�(,� Contractor Signature: � �� � p����.,�r�� �?� � �r� s `��`_f� � COMPLETE VALUATION5 FOi�ALA�RM f�ERMIT (Labor & Materials) Fire Alarm: $ �TZ� � �� ,;� . =_�� � _.,>for Parce!# Contact Eag/e County Assessors O�ce at 9TlJ-328�8S�O OP Y/S0�' r _- . _ _ LPa�cel # :;: I �! � I �,� ,___�._.- -- ` �"� <�'� G � �. "�` �{ ') � ]cb Addre�s: � � J� ,�j C�' �;'7 � ,+��t� � �- Jo� NamF�: .__� � - - � ��-.r ;�`�e't��C- l�..r''�.�;�`� x � ,. .,, � ,� ;,'r;ti�i� g: � � ���,;� � Subdivis or: � L�gal �esa'iptien Lot: � Block: F��+'� � t �J� L_ _____ --� —! � �� r � r '`r � � � � ,F�one: �I vne�,,Nrt't�rYl S r C� Add es � ,� i�- ��" f � �t��� _ r � l �' (� I��fai�i' �. �: � pi�e �Engi�eer ��- << � � �� Address �:C� ( ���f�-�'u�C���' ��.��G 1( 'r��' � _ _ � -- ���Lt�'EYt , t jr1 �v r.� �_��— �?�` � ��-�` C�'��.�' � E;f�tailed !.acc:i�n of work: (i.e., flcor, urnt #, bldg. #) �� f _�— � nc ai��:� de�riptior� cf tvork� m �� � , ��c}� � �-�� ;��.t �Z 1'r'� ��i`' �c_,!�� r'�'� ���� �_ l �i�t`7T�"'�,1�� �-t � _�..__._.�_ � i n� . , ' �_— -- TOWN OF VAIL FIRE DEPARTM���(T VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIME ALARM PERMIT Permit #: A06-0107 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL �,pplied . . : 11/17/2006 Location.....: 4367 STREAMSIDE CR, Unit#6 Issued . . . O1/08/2007 Parcel No...: 210112305012 Expires . .: 07/07/2007 Project No : OWNER STREAMSIDE CIRCLE PARTNERSHIII/17/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-878 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 CONTR.ACTOR SUPERIOR ALAR.M AND ELECTRONIII/17/2006 Phone: 970-926-8�88 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 Desciption: INSTALLATION OF A NEW MONITORED FIRE ALARM SYSTEM Valuation: $3,661.00 **�*********�*******************�**********�**�*******��********�:*** FEE SUMMARY �*********************�**�:********************************** Total Calculated Fees--> $369.29 Electrical---------> $0.0 0 � $0.0 0 $0.o o Additional Fees---------- $3 6 9.2 9 DRB Fee---------> $p,00 Total Permit Fee--------> Investigation----> ) $369.29 $o.0 0 Payments------------------ $0.0 0 Will Call---------> BALANCE DUE--------> TOTAL FEES--> $369.29 ****************�*��*�********�******************************:�*******************�***�:*���*****�****�:****************�*******�****�**�*�:**�**�:** Approvals: Item: 05600 FIRE DEPARTMENT 11/17/2006 McGee Action: DN Insufficient coverage. Does not meet minimum VFESACtionarAP field adjustment of outside bedroom device O1/05/2007 mvaughan stairway locations. approved with corrections. *�*****************************�*********�***�:*�*�****�*****************OF APPROVAL*�************�*�***********************�*�****�*�* CONDITIONS ***************�*�***********************�********�:***��**************************�***�*******�*�***�**�***�****�*****�************************�* DECLARATIONS reb acknowledge that I have read this application, filled out in fizll the inlorma�theinformat on and plot planut tcomply I he y plan, and state that all the information as required is correct. I agree to comp y w ith all Town ordinances and state laws, and to build this structure accord'i dina ces of he Town a pli ab elVthe�e o odes, design review approved, International Buildmg and Residential Codes and ot er o REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL FIRE DEPARTMb��T VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIME ALARM PERMIT Permit #: A06-0107 �U� J�� \� Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL A lied . . : 11/17/2006 Location.....: 4337 STREAMSIDE CR-TRILOGY #6 Ipp ed . . . O1/08/2007 Parcel No...: 210112213004 Expires . .: 07/07/2007 Project No : -��� •6C�1� OWNER STREAMSIDE CIRCLE PARTNERSHIll/17/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-878 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 CONTRACTOR SUPERIOR ALARM AND ELECTRONIII/17/2006 Phone: 970-926-8788 P.O. BOX 4910 EDWARDS CO 81632-4910 License: 429-5 Desciption: INSTALLATION OF A NEW MONITORED FIRE ALARM SYSTEM Valuation: $3,661.00 ******************************************************************** FEE SUMMARY ***********************************************************� Total Calculated Fees--> $369.29 Electrical---------> $0.0 0 $0.0 0 $0.00 Additional Fees----------> 369.29 DRB Fee---------> $0.00 Total Permit Fee--------> $ Investigation----> > $369.29 $0.0 o Payments------------------ $p.0 0 Will Call--------> BALANCE DUE--------> TOTAL FEES--> $369.29 ******�**�*****�*�*****�*******************************�************�****�**********�************�***************************�******�***�****��� Approvals: Item: 05600 FIRE DEPARTMENT 11/17/2006 McGee Action: DN Insufficient coverage. Does not meet minimum VFES standards. O1/05/2007 mvaughan Action: AP field adjustment of outside bedroom devices, and stairway locations. approved with corrections. *******��****�*****�**********�*�**********�*�**********************NS OF APPROVAL**�**�**�***�**��******�**�*****�*******��****�*��* CONDITIO ****�*****��***�*******�*******�*****�*�******************************ARATIONS***�***��*******��:****�*******�*�******�****�*��*�*�*****�*� DECL I hereby acknowledge that I have read this application, filled out i�ee totcom ly w th the informat on and plo planutotcomply plan, and state that all the mformation as required is correct. I ag P with all Town ordinances and state laws, and to build this structure accer o dinan es of the T wn appli ab el ther�etoodes, design review approved, International Building and Residential Codes and oth REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS 1 �VANCE BY TE NE AT 47 -2135 FR M 8:00 AM-5 PM. ,. �_ SIGNATURE OF N C N FOR HIMSELF AND OWNEF **�****�*************�***********�****************�***�*****�**�**�*�****�****�**�**�**Statement TOWN OF VAIL, COLORADO **�x��x�x******�x�x�**�x****:�*****:x****�:************�x*****�**��x**�x*****�*****�*�x�x*:x��x:��x*********** Statement Number: R070000020 Amount: $369.29 01/08/In��08DDG � Payment Method: Check Notation: Superior Alarm 3854 ----------- -------------- ----- Permit No: A06-0107 YP T e: ALARM PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4337 STREAMSIDE CR-TRILOGY #6 Total Fees: $369.29 Total ALL Pmts: $369.29 This Payment: $369.29 0.00 Balance: $ *�***********�******�****�**�x**�******************�******�***�:*********�x**�x�x***********�x**�x�x ACCOUNT ITEM LIST: Current Pmts Account Code Description ____________ ------------------ ------- ------------- ---- 137.29 BP 00100003111100 FIRE ALARM PERMIT FEES 232,00 PF 00100003112300 PLAN CHECK FEE5 ------------------------ � +-i � -(� w APPLICATION WILL NOT BE ACC D IF INCOMPLETE OR UN I r���-�`�� Project#: . � Building Permit#: �'" � Alarm Permit#: , � ; �. WN OF VAIL FIRE ALARM-PERMIT APPLICATION TOWN OF VAIL ` T Commercial &Residential F���an�d must�nciude nforma o listed on�he�f 75 S. Frontage Rd. ap lication subm�tta 7"`�page of this form. Application will not be accepted w�thout t �s Vail, Colorado 81657 �nformation. CONTRACTOR INFORMATION Town of Vail Reg. No.: Contact Person and P����� Fire Alarm Contractor: ��C� G� �'tA�-�,I/���' ��� `�" � 5 � ax#: 2.l.Q � � E-Mail Address: (�(,(,�52 (�-' � Y��'�`'� �L��� Contractor Signature: � � COMPLETE VALUATIONS FOR ALARM PERMIT (Labor &Materials) .% �ij� Fire Alarm: $ ���0 , � ' �� Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit f��r��'k�`��'� ����?�j'� ��1�for Parce/# Parcel # :;� I 7� ( I aa ► 3 d� Job Address: f� 3 �� �%��j y�5(�(i C r . Job Name: T�'��� u��(,fi� Filin �J� �4�� Subdivision: �(� Legal Description Lot: `� Block: 9� / � � �. �_� � Phone: Owners Name:S',��Sid,a C�iLQ�R'rI� Address: �9�3� , 5 r� ��j I�,yI,U P,hone: �f�� I`�L-D`C���� Engineer: ���n (�S�, ��1 A d d r ess: g 3 q � ���f��_��,(� � Detailed Location of work: (i.e.,floor, unit #, bldg. #) Detailed description of work: ��u��,� � � , ,�(�.�� C�`�tis 1���t,tC�1 z - �,c�P I�.X - Work Class: Ne ) Addition ( ) Remodel ( ) Repair( ) Retro-fit ( ) Other( ) � Type of Bldg.: Single-family ( ) Two-family Multi-family( ) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation units in this building: Z_ Does a Fire Alarm Exist: Yes( ) No Does a Fire Sprinkler System Exist: Yes( ) N � *,�**�*****,��*�**�****��X*�x�**x**�*****FOR OFFICE USE ONLY***:�******�**�**�*�*******:�**x******x `� Other Fees: �ate Receiued: �� Acce ted B . ��� Pubtic Wa Rermit Fee: `�� Occupancy Group: Page 1 of 4 12/05/2005 F:\cdev\FORMS\PERMITS\Fi re\alarm_perm_12-05-05.doc TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE PO5TED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E06-0130 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL A lied . . : �g��2�2006 Location.....: 4367 STREAMSIDE CR, Units 5&6 Is ued . . . 08/07/2006 Parcel No...: 210112305012 Expires . .: 02/03/2007 Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI08/02/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT PATTERSON ELECTRIC CO 08/02/2006 Phone: 970-468-616 P O BOX 483 DILLON CO 80435 License: 208-E CONTRACTOR PATTERSON ELECTRIC CO 08/02/2006 Phone: 970-468-6166 P O BOX 483 DILLON CO 80435 License: 208-E Desciption: ELECTRICAL FOR DUPLEXSquare feet: 9000 Valuation: ��•� *****************:�****�*********************�***�:***********�****** FEE SUMMARY ******�*******�****�:*****************�********�*�*********** Total Calculated Fees--> $411.25 ElectTical---------> $4 0 S.2 5 $0.0 0 $0.00 Additional Fees----------> $411.25 DRB Fee---------> $o Qo Total Permit Fee--------> Investigation----> $411.2 5 $3.o o Payments------------------> $0.0 0 Will Call---------> BALANCE DUE--------> TOTAL FEES--> $411.25 ****************�***�****************�:�***�**�:****�*************�*************:�******�*:�*********�*****�***�:****�**********�*****�*****�******:x* Approvals: Item: 06000 ELECTRICAL DEPARTMENAction: AP 08/07/2006 shahn Item: 05600 FIRE DEPARTMENT *******�*�*************************************�*************�:******NS OF APPROVAL*�****�****�******�*********�***********�**�*****�: CONDITIO Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAN - ���:*�**�***��*********************�:************�******�****�***�***�**ARATIONS**�***�*�*�********************�**�*�**********��***��*�**** DEC I hereby acknowledge that I have read this application, filled out in e�otcom l�rw'th theinformation and plot planutotcomply plan, and state that all the information as required is correct. 1 agre P Y with all Town ordinances and state laws, and to build this structure accoro dinances of the Town a pli ab el the�etoodes, design review approved, International Building and Residential Codes and other REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E06-0130 '�C; - C�l l�( Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL ppplied . . : 08/02/2006 Location.....: 4337 STREAMSIDE CR Issued . . . 08/07/2006 Parcel No...: 210112213004 Expires . .: 02/03/2007 Project No : ���;�� --L�'�'� OWNER STREAMSIDE CIRCLE PARTNERSHI08/02/2006 3033 E 15T AVE STE 815 DENVER CO 80206 APPLICANT PATTERSON ELECTRIC CO 08/02/2006 Phone: 970-468-616 P O BOX 483 DILLON CO 80435 License: 208-E CONTRACTOR PATTERSON ELECTRIC CO 08/02/2006 Phone: 970-468-6166 P O BOX 483 DILLON CO 80435 License: 208-E Desciption: ELECTRICAL FOR DUPLEXSquare feet: 9000 Valuation: ��•� FEE SUMMARY **********�**********************************�:*****�******** ***************************�***********�**************************:k $411.25 $4os.25 Total Calculated Fees--> $p,o0 Electrical---------> $p.0 0 Additional Fees----------> DRB Fee---------> $411.25 Total Permit Fee--------> Investigation----> $0.00 � $411.25 $3.o o Payments----------------- $o.o 0 Will Call---------> $411.25 BALANCE DUE--------> TOTAL FEES--> **********************************�**********************************************************�*�:***********:�************************************ Approvals: Item: 06000 ELECTRICAL DEPARTME Action: AP 08/07/2006 shahn Item: 05600 FIRE DEPARTMENT ************�*********�*************************************�**�******S OF APPROVAL****************�*�******�*********************�** CONDITION Cond: 12 (BLDG.) : FIELD INSPECTIONS AR.E REQUIRED TO CHECK FOR CODE COMPLIANC • ****�*************************�*********************************************TIONS****************�************�**********�**�**************** DECLARA I hereb acknowledge that I have read this application, filled out in full tcom l�rw th theinformarion and plo planutotcomply Y plan, and state that all the information as required is correct. I agree to p y with all Town ordinances and state laws, and to build this structure accoro dinan es of the Town appli ab elVthe�to�es, design review approved, International Building and Residential Codes and other REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEP E AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE O OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF ***�****�***�*****************�************************�******��***********�***********Statement TOWN OF VAIL, COLORADD *****�*�**�**************�***�x*****��*********�x�x*************�***********�x***��*****�:�*�:*** Statement Number: R060001171 Amount: $411.25 08/07/In0�01LT5 PM payment Method: Check Notation: Patterson / 5179 ----------------------------- --- ---------------- -------- Permit No: E06-0130 YP T e: ELECTRICAL PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4337 STREAMSIDE CR Total Fees: $411.25 Total ALL Pmts: $411.25 This Payment: $411.25 $0.00 Balance: *******�*******�:***************************��:*******:x**************************�:******�:***** ACCOUNT ITEM LIST: Current Pmts Account Code Description ____________ ------------------------------ 408.25 EP 00100003111100 ELECTRICAL PERMIT FEES 3 .00 WC 00100003112800 WILL CALL INSPECTION FEE ---------------------- pppLICATION WILL NOT BE ACCEPTED IF INCOMPLET e��NSIGNED���d� �6�}C�� Pro� � Building Permit#: ��-- v 1 � 9 � � Electrical Permit#: � 3� � �:� �� � 970-479-2149 (Inspections) ������ � 75 S.Frantage Rd. Vail,Colorado 81657 TOWN OF VAIL ELECTRICAL PERMIT APPLICATIO CONTRACTOR INFORMATION Town of Vail Reg No.: Cont Pe n and Phone #��'��I� Electrical Contractor: �. �. `� �f � �a-� � '�- ° _ � FaX#: q�, . ��' �� E-Mail Address: � `" 'f� �' Contractor Signature: E S . FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials) COMPLET Q AMOUNT OF SQ Ff IN STRUCTURE: � ELECTRICAL VALUATION: $ c-F """ Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www.ea le-coun ,com for Parce/# Parcel # ]ob Address: ��3 '7 � ' -�� Job Name:�2��•�v �--�— Subdivision:S �-s�� Legal Description Lot: Block: F���ng' phone: Owners Name: Address: Address: Phone: Engineer: Detailed description o�work: � �� �� �/ ���� r Remodel ( ) Repair ( ) Temp Power( ) Other ( ) Work Class: New (� Addition ( ) No � � Exterior( ) Both Does an EHU exist at this location: Yes( ) Work Type: Interior( ) � Type of Bldg.: Single-family( ) Duplex Multi-family( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No No Does a Fire Alarm Exist: Yes ( ) No (' ) Does a Fire Sprinkler System Exist: Yes ( ) ���Z *��r*****�*�*�*���*****�����*���****** *���*��*�*����*�*�.�*,���,������**********FOR OFFICE USE ONLY �pther�'Fees: ' ' Date Received. rv:DRB Eees. ' _Acce ted B . Pfanner Si n-off: � li/23/2005 F:\cdev\FORMS\PERMITS\Buildi ng\electical�ermit_l 1-23-2005.DOC Page 1 of 2 TOWN OF VAIL DEPARTMENT OF COMMUNITY D�VELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M07-0013 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL p lied . . : O1/30/2007 Location.....: 4367 STREAMSIDE CR UNITS 5 AND 6 Ip ued . . . 02/O1/2007 Parcel No...: 210112305012 Expires . .: 07/31/2007 Legal Description: Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI01/30/2007 3033 E 1ST AVE STE 815 DENVER . CO 80206 APPLICANT FIRE WORKS HEARTH & PATIO, I01/30/2007 Phone: 970-928-875$ P.O. BOX 2133 GLENWOOD SPRINGS CO 81601 License: 243-M CONTR.ACTOR FIRE WORKS HEARTH & PATIO, I01/30/2007 Phone: 970-928-8758 P.O. BOX 2133 GLENWOOD SPRINGS CO 81601 License: 243-M Desciption: INSTALL 2 FIREPLACES IN EACH UNIT Valuation: $12,000.00 #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0 Fireplace Information: Restricted: FEE SUMMARY *******************�**************************************** *******************�*****�**********�******�***�******************:�* Total CalCUlated Fees---> $303.00 Mechanical---> $24 0.oo Restuarant Plan Review--> $0.00 $p,00 � $303.0o AddirionalFees-----------> P1anCheck---> $60.00 TOTALFEES-------------- To�per[nitFee----------> $303.00 0.00 � $303.00 Investigation-> $ Payments-----------------'- Will Call-----> $3.0 0 BALANCE DUE---------> $o.0 0 ********�*�****:�***************************************************�***�***********************************�******�*�************************** Item: 05100 BUILDING DEPARTMENT Action: AP Ol/30/2007 cgunion Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAN • Cond: 22 (BLDG. ) : COMBUSTION AIR IS REQEDRBD TO�CO PVAIL? OF THE 2003 IMC AND SECTI 304 OF THE 2003 IFGC AS MODIFI Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS CHApTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL IQGCPMENT MUST COMPLY WITH CHAPTER 3 OF THE 200 IMC AND CHAPTER 3 OF THE 2003 Cond: 31 (BLDG. ) : BOILERS SHALL BE BU�IBDEOFLOORONG,OF NONCOMBUSTIBLE CONST. UNLES LISTED FOR MOUNTING ON COM Cond: 32 (BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIO TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVE MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. �***************�*�******************�***************�***********CLARATIONS******�*�************�****�*�*�*�****************�********�* DE I hereby acknowledge that I have read this application, filled ouai�ee totcom ly w th theinformat on and plo planut tcomply plan, and state that all the information as required is correct. I g P with all Town ordinances and state laws, and to build this structure other o dinances of he Town appli ab el the�etoodes, design review approved, International Building and Residential Codes and REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M07-0013 `�� � C;, l`� Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL p lied . . : O1/30/2007 Location.....: 4337 STREAMSIDE CR UNITS 5 AND 6 Ip ued . . . 02/O1/2007 Parcel No...: 210112213004 Expires . .: 07/31/2007 Legal Description: �CZ SZj� — �j�b � Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI01/30/2007 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT FIRE WORKS HEARTH & PATIO, I01/30/2007 Phone: 970-928-8758 P.O. BOX 2133 GLENWOOD SPRINGS CO 81601 License: 243-M CONTRACTOR FIRE WORKS HEARTH & PATIO, I01/30/2007 Phone: 970-928-8758 P.O. BOX 2133 GLENWOOD SPRINGS . CO 81601 License: 243-M Desciption: INSTALL 2 FIREPLACES IN EACH UNIT Valuation: $12,000.00 #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0 Fireplace Information: Restricted: FEE SUMMARY ********************�***********�**************�***********� ***�**�******�******************�:***��*****�************************ Total Calc�lated Fees---> $303.00 $0.00 0.00 Mechanical---> $240.0o RestuarantPlanReview--> 303.00 AdditionalFees---------> $ Plan Check---> $60.00 TOTAL FEES-------------� $ Total Permit Fee---------> $303.00 0.00 > $303.00 Investigation-> $ Payments---------------- Will Call-----> $3.0 0 BALANCE DUE---------> $o.0 0 *****�******�**�**�******�:****�****��**�***��****�*�*�*�************�:*��******�*�******�**************�**�****�*****�******�****�*******��*�**** Item: 05100 BUILDING DEPARTMENT Action: AP Ol/30/2007 cgunion Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANC . Cond: 22 (BLDG. ) : COMBUSTION AIR IS IF�IEDRBY TOWNCOFpVAIL? �F THE 2003 IMC AND SECTIO 304 OF THE 2003 IFGC AS MOD Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER' S INSTRUCTIONS CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFG . Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL IQGCpMENT MUST COMPLY WITH CHAPTER 3 OF THE 200 IMC AND CHAPTER 3 OF THE 2003 Cond: 31 (BLDG. ) : BOILERS SHALL BOMBUSTIBDEOFLOORING,OF NONCOMBUSTIBLE CONST. UNLES LISTED FOR MOUNTING ON C Cond: 32 (BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRI TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVE MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 .6 . **�***�*�******��********�*�*********��****�***�******�*�*�**�**ECL*ARATIONS*�**�*�**�*��***�***��***�******�*�*****�**��***�*�:*�****�:** D I hereb acknowledge that I ha�e read this application, filled out in full the informatioheinformarion and plo planutotcomply Y plan, and state that all the information as required is correct. I agree to comply wit t with all Town ordinances and state laws, and to build this stres and other o dinances of he Town ppli abll the�etoodes, design review approved, International Building and Residenrial Cod REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIG RE OF OWN ONTRACTOR FOR HIMSELF AND OWNEF ��****�***��**��**�***�*************�*�**��***************�**��*�***�*���**��*�********Statement TOWN OF VAIL, COLORADO **********�*�*�x�**�x�:*�*�x*****�x��x��x�x�**�***�x*�x*:�*�x��x�x�x*�x:��:**��x*��x*��x********�x�x*�*:x********��* Statement Number: R070000116 Amount: $303 .00 02/01/In0�03LT4 PM Payment Method: Check Notation: Fireworks/ ck 10246 --------- ----------------------------------- Permit No: M07-0013 Type: MECHANICAL PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: 4337 STREAMSIDE CR UNITS 5 �D Total Fees: $303 .00 This Payment: $303 .00 Total ALL Pmts: $303.00 Balance: $0.00 �x*�*******�:***********�*�************�*********�*********�*�x*�**�*�*****�x****�**�********�x*�x ACCOUNT ITEM LIST: Current Pmts Account Code Description ------------------ ------- ------------------ 240.00 MP 00100003111100 MECHANICAL PERMIT FEES 60.00 PF 00100003112300 PLAN CHECK FEES 3 .00 WC 00100003112800 WILL CALL INSPECTION FEE --------------------------- , APPLICAT�JN WILL NOT SE ACC�PTED IF INCOMPP O] ��NSIGQ�1� `���,�� �� �� Building Permit #: -o !!9 l � r Mechanical Permit #: - `� �� � Q � F 970-479-2149 (Inspections) �1 TOWNOFYAIL TOWN OF VAIL N1ECFiANICAL PERMIT APPLICATi�iV 75 5. Frontage Rd. Permit will not be accepted without the following: Vail, Colorado 81657 " Provide Mechanical Room Layout drawn to scal��tp�incfude: �; Mechanical Room Dimensions Combustion Air Duct Size and Location � �� Flue,Vent and Gas Line Size and Location �AN 2 6 200� �, Heat Loss Calcs. Equipment Cut/Spec Sheets � ��.;.���-�-'- _ _�.._. Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www.eaale coun .com for Parc°/# � Parcel # (Reyuired if no bldg. permit # is provided above) �' Job Address: vK` t � �'� Job Name:� �r� __—__—, �� ��9 / /�.J I j Subdivision: '� � Legal Description Lot: � Block: Filing: ; Address: Phone: ' �Owners Name: — �, � Address: Phone: I j Engineer: -- '� ', Detailed description of work: Cr �K�,�'�' ll� ;�,, �( � ���• �-� _,� , � Addition Alteration ( ) Repair ) Other ( ) '� �, Work Class: New (k) � ) Location: Interior O Exterior O Other O Does an EHU exist at this location: Yes O No O �'� I Boiler ��, Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) � i Type of Bldg: Single-family O �° � ' No. of Accommodation Units in this building: i j, No. of Existing Dwelling Units in this building: �. ; ��. No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin ( � YP p g pP �I li No/Type of Fireplaces Proposed: Gas Appliances (� Gas Logs (� Wood/Pellet O Wood Burning (NOT ALLOWEG) i � Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes O �o � i COMPLETE VALUATION FOR MECHANICAL PERMIT (Labor & Materials) v� �� ; MECHANICAL: $ � CONTRACTOFt INFORMATION � Mechanical Contractor: Town of ail . No� Contact and Phone #'s: � 'i � 70- f- II� � � � � � i �,�E �cJ � � Contractor Signature: ' *************�**********FOR OFFICE USE ONLY********************�******** i Planner Si n-off: '� Acce ted B : ' Other Fees. � DRB Fees: __ I Date Received: � ----- F:/everyone/forms/mechperm �o 3 � TOWN OF VAIL DEPARTMENT OF COMMUNITY D�,VELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M06-0154 Job Address: 4367 STREAMSIDE CR VAIL Status . . . : ISSUED Location.....: 4367 STREAMSIDE CR, Units 5&6 Applied . . : OS/26/2006 Parcel No...: 210112305012 Issued . . . 07/21/2006 Legal Description: Expires . .: O1/17/2007 Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI05/26/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT R & H MECHANICAL LLC , 05/26/2006 Phone: (970) 328-2699 PO BOX 810 EAGLE CO 81631 License: 184-M CONTRACTOR R & H MECHANICAL LLC 05/26/2006 Phone: (970) 328-2699 PO BOX 810 ' EAGLE CO 81631 License: 184-M Desciption: BASE BOARD RADIANT HEAT Valuation: $77,000.00 Fireplace Information: Restricted: Y #of Gas Appliances: 0 �i of Gas Logs: 0 {f of Wood Pellet: 0 *******�*****:�****************************************************** FEE SUMMARY ***�:*�**�:***************��********�*�***********�*********** Mechanical---> $1,54 0.0 o Restuarant Plan Review--> $o.o o Total Calculated Fees---> $1�92 0.0 0 Plan Check---> $3 8 5.o o TOTAL FEES--------------> $1,92 8.0 0 Additional Fees-----------> $ Investigation-> $0.0o Total Permit Fee----------> $1,928.00 Will Call-----> $3-00 Payments-----------------> $1,928.00 BALANCE DUE---------> $0.0 0 *�*�***�******�**�******�*************�******************�******************�*�*�**********�*****�*****�**************************�****�*�******* Item: 05100 BUILDING DEPARTMENT 06/19/2006 cgunion Action: AP Item: 05600 FIRE DEPARTMENT - CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG. ) : COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. . Cond: 31 (BLDG. ) : BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 .6 . *****�*************************�************�***********************�*�*�*******�*�**�************************�************�*****�****�********** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M06-0154 Job Address: 4327 STREAMSIDE CR VAIL Status . . . : ISSUED Location.....: 4367 STREAMSIDE CR Applied . . : OS/26/2006 Parcel No...: 210112213003 Issued . . . 07/21/2006 Legal Description: . , Expires . .: O1/17/2007 Project No : � ��� ��� OWNER STREAMSIDE CIRCLE PARTNERSHI05/26/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT R & H MECHANICAL LLC 05/26/2006 Phone: (970) 328-2699 PO BOX 810 EAGLE CO 81631 License: 184-M CONTRACTOR R & H MECHANICAL LLC 05/26/2006 Phone: (970) 328-2699 PO BOX 810 EAGLE CO 81631 License: 184-M Desciption: BASE BOARD RADIANT HEAT Valuation: $77,000.00 Fireplace Information: Restricted: Y N of Gas Appliances: 0 #of Gas Logs: 0 N of Wood Pellet: 0 ******************************************************************�* FEE SUMMARY *************************************�********************** Mechanical---> $1,540.0o Restuarant Plan Review--> $0.00 Total Calculated Fees---> $1�920.00 Plan Check---> $3s5.00 TOTAL FEES--------------> $1,928.00 Additional Fees-----------> $ Total Permit Fee----------> $1,9 2 8.o 0 Investigation-> $o.oo > $1,928.o0 Will Call-----> $3.0o Payments------------------- BALANCE DUE--------> $0.00 ****************�****�**************************************************************�******************************************************�***** Item: 05100 BUILDING DEPARTMENT 06/19/2006 cgunion Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG. ) : COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANLTFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. . Cond: 31 (BLDG. ) : BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIO TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DR.AIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 .6 . ****************�*******************�************************�************************�******************************�*************************�* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV NCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. � SIGNA URE OF WNER OR CON RA O FOR HIMSELF AND OWNEF ********�***********+******�********************��*****************�*******************Statement TOWN OF VAIL, COLORADO **�:****************�x*************************�:****�************�:********�x******************* Statement Number: R060001043 Amount: $1,928.00 07�initOODDG 42 AM Payment Method: Check Notation: R & H Mechanical 17968 ---------------- -------- Permit No: M06-0154 YP T e: MECHANICAL PERMIT Parcel No: 2101-122-1300-3 Site Address: 4327 STREAMSIDE CR VAIL Location: 4367 STREAMSIDE CR Total Fees: $1,928.00 This Payment: $1,928.00 Total ALL Pmts: $1,928.00 Balance: $0.00 *�:**********�x*****:x****************�************�**************************�**************** ACCOUNT ITEM LIST: Current Pmts Account Code Description ----------------------- ------------------ ----- 1�540.00 MP 00100003111100 , MECHANICAL PERMIT FEES 385.00 PF 00100003112300 PLAN CHECK FEES 3 .00 WC 00100003112800 WILL CALL INSPECTION FEE ----------------------------- � May. 25. 2006 2:41PM R°H MECHANICAL . No. 5571 P, 2 t APPLICATION WrLL NOT BE ACCEPT�D ZF INCOMPLET�OR UNSI � Project#: � �� • b� � Building Permit#: a -U ll • 1 MechanicalPermit#: �,a(,• !S� � . 970-479-214�,(Inspections) � �1(1�'NOFYAIL TOVUN OF VAxL MECHANICAL PERMI'� APPLIC ON 75 s, Frontage Rd. Permit will not be accepted without the following: � Vail, Colarado 81657 � � . � Provide Mechanical Roorn Layout drawn to scate�o,include: � o Mechanical Rvom Dimensians � • • o Combusticn Air Duct Size and Location � � � o Flue,Vent and Gas Lin�Size aod I,ocation � � �. o Heat Loss Calcs. � o Equipment CutJSpec Sheets � CON�'RACTOR INFORMA�'ION � � � � Mechanical Contractor: Town of Vail Reg. No.: Cont�ct and Phone#'s: . _ 32��z�9�P E-Mail Address: . � � ' , Contractor Signature: . ° ' . COMPLETE YAI.UATION FOR NiECHANICAL PEitMIT Labor& Materials � MECHANICAL: $ �]`J DO ""-` Contact Ea le Coun Assessors O�ce af 97Q 3�'8-8640 or visit www.ea le-coun �.com fo�Pa,rc�e/# Parcel # �p Z . Job Name; -�� � /J � 7ob�Address: � 6.7 $�'��� ��-� 1GG('D L!/j�v���, �� � � �.ega� Description t,o : � Block: Filing: , �. � ' Subdivision: g � �/�- Owners Name:�fi�eann S� Cc�c Address:3oa8 E. �st� g i Ph : � � �, co v o- .��- �-9% Engineer: �-' Addre :I!2 13�.a � o ai ph ��yy y— S yr Detailed description of wark: ' � � � � • � �Ja.�(3oa�v� �a,°Qca'r�- �e��' . • Work Class: New Addition ( ) Afteration ( ) Repaic(• ) Other( ) ' Boiler Location: Interior( ) Exterior( ) Dther( ) Does an �HU exist at this locatian: ' Yes( ) .No Type of Bldg; Single-famil Duplex( ) Multi-family( ) Commercial( ) R�staurant( ) Other( ) �lo. of F�cisting Dwelling Units in this building: No. of Accommodation Units in this building: , ,. ., No/T e of Fire laces E�cistin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/'I'ype of Fireplaces Proposed; Gas Appiiances( ) Gas l.ogs( ) Wood/Pellet( ) Wood Buming (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No( ) - . � � . �` , �x�* �******�***�*�x**�*FOR OFFrCE USE ONL�(*****�*********************** . �,� '�'Ottier�Fee's�•��ir,`A�'R,Y'�i��.l��Y�:T��:��r�:.Planeer'.SI n�off., � :k>;�.�;;;.-:�;,AcY� ted;`� :a p,.:y.4�?-�-':� � , � � �� DRB�•Feesi: =:.;�;:,:.•���,;;,•.�,:. .Uate Recelved:.::,�;:;;:=;;a::.- �.:::.��..,- --��.��,;:";::�r�i,.. � . . , , .� ;.i:�.�i- May. 25, 2006 2;41 PM Rp�H MECHANICAL N0' ���� P� 3 � Hca��alc�o,�Jts��ee� r, . R11=.09 R19=.052 � R3p=.033 R2.8�.357 � AREA SQUARE R VALUE U UA DT� BTU's REG OUTPU7 � I ��' � � I �0 3�(�0 `�a� ��(�� � � . ��ooRS � �� �3, . � �v� �v ��33 ���� � �� ��� � � � � s�� � CEILING , '1 �� J�^"�f � ��r (� � � l �j � �0 a� ��OS , . WALLS � • / . ��� � � ,�,5� �?� � �� � 31 ��3 . � �.. .. . W(NDOWS • � I - . .o ��'S S��`� 36�`� � . 33�,3.�. -. =� .�. ��CS � . �� i . . , . ,. INFILTRATION ' 1000 x.7� 0.1� � " �_/�.N��S� � � �% � � CONTI�ICTQR: �I B�'lJ's Ot1TPUT; � I• T � . . ADDR�SS: ' �- l�0'-.A'Gc�I�L- Sl�OO EFFICIENCY: • (�' ,� '7 ( � .` ' � � ..' , ADDRESS: �� G� ���'•�-� ALTITUDE: �6�) �����f • . �. ; . _ -----t •. PHONE: � l�' -f `( � " J� �� 70TAL BTUs INPU7�lEEDED,������ :�• .. � JOB NAME: � ��"� � � � GARAGE: �-C�J : � . ADDRESS: �3�a� 1 S1 I��- ��e�NOW MEI.T: �� � ��� , : PERMIT#: TOTAL BTUs: ��� S�I •. . ' Equipm�nt Spec. I�S �Ll (�c � ' /�l�U�t.�- �� — � �f? � . . � ..�___., . � ST������ss -�T�l�-t- , �'0��,�0����r� � G�:S �3�r ��.s�. . . °(�J�v�� l.Sc� �T� ����1— �:�-e.� � � . . ' � � . . F (�"l f� � �� � ��� �� ��3�� i C�t7�vf'i�.8���/�Z � (1� �9�c,(-�- V 1� 1 fi'" '., . , �. May. 25, 2006 2.41PM p°H MECHANICAL No. 5577 P, 4 . r��� Z 1 �` . i� � � � �\ , '� � � 3 fr�vr, ✓��,,,T-�- „ C.l�--�f�o���t /Lcn� �`�,,�....,. . . ����. � ���s�` �� I L���� .V� �1�� o�M �����i�I G�� '� : 1' „^�� ���� � May. 25. 2006 2:42PM R��N MECHANICAL No. 5577 P, 5 J�r�� � � � << 3`� P Jc� ��`� � �° � c,�- � ° � __^_.�..-__ � ��. . , �S / �� �L,o�y �N � � 6 ��.-c��y� c�L �o�i y�d,� < <�,,, May. 25. 2006 2;42PM p°H MECHRNICAL ���.,� No. 5511 P. 6 TOP TEN LI��T' GENE�►L 59'ECIFICAT109V5 The ,A,dvantages o f the �,�5o T'Z°° ' rq00 14"x 155"x zz" 17"x 15.5"x�.Z" 72"x 30"x 46" ,.� • 801bs. I I O ibs. Z301bs, (� 30 PSI 30 PSI 30 PSI � Natural,Propane Natural.Propane Nacural,Propape 105'equivalenc 105'equivalent 80'r}",100'-6" ' IlZ"NPT Il2"NPT �"NPT I. Available in both Natural Gas and , zoo=F 2oo°F zoa°F , 30°F 30°F 30°F Propane ve►sions with�a modulation . � . R6Q��rea R¢quired Re uired . system �hat eliminates additionaf models. 2 State=of-the-art sealed modulation � csA.AGA,CSAus cs�►.AC,n,csnus, CS�►,AG�A�CSA�s, ASME com6u:tion system wi�h fiot surface . � igni�ion., . � •, ' � �. � 3. Patented 316L.stain(ess,io�densing heat;�, yEATING SPECIFICATIONS . � � . exchanger�provides ultimate efficiendes. T��o T;zoo raoo � q��..NI tonnections� are conveniendy loiated . 34. i5o zs-zoo 15-399 foi ease of installation, .. � ' . . •� 3 i.z• i 3e �za- iai Z2.7-363 5. Wall mount configuration saves valoable�''.,:.�'' 9s� 9r� 96x • � ��' 929G 91% 9196 � itoar.space:�. . . .. . �� � � • i z��s i 3�@ i o i a�(�zo � 6� .Vents easily.with'conventionaf ABS, PV�,. ,� ;"� 314°N�r �°«�H,3/�"on C , i"NPT*°" � � or.CPVC plastic piping. � . .. . � �� � Moa�B � 7. TheTRINITY�tias mdustry-leading .:,... ��. . ��. ;. '�. a.4:i a:i ie:i � ��,modulation rates,which significantfy . � increasei comfbrt,while redueing ryd�ng . o r�o�ai o Ua�ai Insralled , . �� and fuel consumption;..., :: ��:.:� �. . � � 8� .The distinctivve casing design redu�es` �..,:,��� �; , � �. cosdy�,standby loues,while virtually �::`':..'�`; DOMESTIC F#OT WATER eliminating, rnm6ustion noises. ,, (CombiVarsion) 'rj�p Ti200 • • � 9. High-capacit� plate heat.exchanger�on �a°Nar o���i�"�^�eC � combmation models provides ample� ' ; � "�' .• . 15� e �8' 10 dofiesti�,bot V+ater. � ' '` '• •. Eleccronic Modulacion IQ The jRIN11Y is certi�ied,.designed�and;';�.`��;:.'.���°�, 4,0 �i o°F 5.s i i o°F rated�to st�ict �SA,AGA,ASME and 3.s izo°F a.s izu°�' �US COdCS:. . ' ; � . . 3.1 130°F 4.5� 130°F .. , ',,,. , . � . ,. �:. � � � ** Note: Ti400 comes standard with built-in primary laop• � Connettion indicated is for secondary loop connettion. '." ."As.we conttnue co improve ou�produc�s,we reacrve the righs co�hange specificadons wrchouc nocice. . , , . . . � . , pD�BM . , .. • ���' ' � e�.+ NY THEAMAL INC. � Us �O � � � ..� , . NYTHERMAI.INC. DISTRIBUTED BY: � 31 Industrial Drive Sussex,New Brunswick � E4E 2R7 Ganada � � Te1:506•432-1130 , ' Fax:506-432-1 I 35 �� www.n�thermal.com � no No, 5577 P. 1 May. 25. 2006 2:41PM �I MECHANICAL R & N MECNAN1CAl, L�� PO Box 810 �EAGLE,CO 81631 PHOntE 970328-2699�FaX 970-328-0234 To: Joe k`rom: Naxicy Com a�. : Town o�Vail Date: 5/25/06 Phoz�e: 479-2�39 Fa es: 6 � ��• 479 2452 Re: Perm�it application Joe, ,A,ttached�s ouz permit applicat�on for T�ilogy Units S &6located at 4367 Stxeamsade Ci�cXe. z�you have any question,s please�eel free to caJ.l me at the offace. Thatilc you, TOWN OF VAIL DEPARTMENT OF COMMUNITY D�VELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Permit #: P06-0083 Status . . . : ISSUED Job Address: 4367 STREAMSIDE CR VAIL Applied . . : 08/04/2006 Location.....: 4367 Streamside Cr, Units 5&6 Issued . . . 08/07/2006 Parcel No...: 210112305012 Expires . .: 02/03/2007 Legal Description: Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI08/04/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT AVON PLUMBING & HEATING 08/04/2006 Phone: 970-748-094 PO BOX 8701 AVON CO 81520 License: 314-P CONTRACTOR AVON PLUMBING & HEATING 08/04/2006 Phone: 970-748-0944 PO BOX 8701 AVON CO 81520 License: 314-P, Desciption: TORZETTO BLDG 5 & 6-COMPLETE PLUMBING Valuation: $100,000.00 �� 1i of Gas Appliances: ?? It of Gas Logs: ?? #of Wood Pallet: 7? Fireplace Information: Restricted: FEE SUMMARY ***********�***�******+***************************************:�**:�*** 1,g78.00 *****************�:*************�:****�:*********************** $0.00 Tot31 Calculated Fees---> $ $0.00 Plumbing---> $1,5 0 0.0 o Restuarant Plan Review--> 3�5.0 0 TOTAL FEES--------------� $1,8�8.0 0 Addirional Fees-----------> 1 g 7 g.o 0 Plan Check---> � Total Permit Fee----------> $ $o.00 � $i,s�a.00 Investigarion-> Payments------------------ $o.0 0 Will Call----> $3.00 BALANCE DUE---------> ****:�******�*************************************�*************************************************�*****x:******�************�*******�*�********* Item: 05100 BUILDING DEPARTMENT Action: AP 08/04/2006 JS CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *****�**�*********�*�***************�*********�*****�*********�:***********************�*****�*�:****�***�***************�*�***********��********** DECLARATIONS I hereb acknowledge that I have read this application, filled out in full the�n lorma��e informat on and plo planutotcomply Y plan, and state that all the information as required is correct. I agree to co p y with all Town ordinances and state laws, and to build this structure acco�o dinan es of he T wn appli ab el ther�etoodes, design review approved, International Building and Residential Codes and othe REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THI5 PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Permit #: P06-0083 '�;� -C? �t�( Status . . . : ISSUED Job Address: 4337 STREAMSIDE CR VAIL ppplied . . : 08/04/2006 Location.....: TORZETTO BLDG 5 &6 Issued . . . �g����2006 Parcel No...: 210112213004 Expires . .: 02/03/2007 Legal Description: ��-�-���,C�� «�� �� � Project No : OWNER STREAMSIDE CIRCLE PARTNERSHI08/04/2006 3033 E 1ST AVE STE 815 DENVER CO 80206 APPLICANT AVON PLUMBING & HEATING 08/04/2006 Phone: 970-748-094 PO BOX 8701 AVON CO 81520 License: 314-P CONTRACTOR AVON PLUMBING & HEATING 08/04/2006 Phone: 970-748-0944 PO BOX 8701 AVON CO 81520 License: 314-P Desciption: TORZETTO BLDG 5 & 6-COMPLETE PLUMBING Valuation: $100,000.00 �� N of Gas Logs: �� i{of Wood Pallet: ?? Restricted: ?? #of Gas Appliances: Fireplace Information: FEE SUMMARY ********************************************************************* 1�g78.00 **********************************************************�* $0.00 Tota1C31CUlatedFees---> $ $0.00 Plumbing---> $1,500.00 Restuarant Plan Review--> 3�5.0 o TOTAL FEES--------------' $1�8 7$•o o Addidonal Fees-----------> 1 g�g,o 0 Plan Check---> $ Total Permit Fee----------j $1,s�8.o 0 Investigation-> $o.0 o Payments------------------ Will Call-----> $3.00 BALANCE DUE---------> $0.00 *************************************************************M***********************�***:�*****�****�******�*********�****�*********:�*********** Item: 05100 BUILDING DEPARTMENT Action: AP 08/04/2006 JS CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ******************************************************************************************************************************************�***�** DECLARATIONS I hereb acknowledge that I have read this application, filled out in full�thom lorma��eenformat on and plo planutotcomply Y plan, and state that all the information as required is correct. I agree t p Y with all Town ordinances and state laws, and to build this structure accor o dinan es of the Town applicab elVthe�e oodes, design review approved, International Building and Residential Codes and other � � STS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY;TELEPHONE AT 479-2149 O OUR OFFICE FROM :00 AM-4 REQUE �,�' r PM. , � ;.���e-��� �G�� - ���' C� � ,, �. ********�*********�************�*****�*******************�********************��*******Statement TOWN OF VAIL, COLORADO ********�****�x*****:x*********�x*�:************************��x*****�**************���*********� Statement Number: R060001167 Amount: $1,878.00 08/07/200612:57 PM Check Init: LC Payment Method: Notation: #3223 Avon Plumbing Inc. --------- ---------------- Permit No: P06-0083 YP T e: PLUMBING PERMIT Parcel No: 2101-122-1300-4 Site Address: 4337 STREAMSIDE CR VAIL Location: TORZETTO BLDG 5 & 6 Total Fees: $1,878.00 This Payment: $1,878.00 Total ALL Pmts: $1'870.00 Balance: $ *********************�*************�********�x***�***********�**********�******************** ACCOUNT ITEM LIST: Current Pmts Account Code Description ____________ --------- ------------ ----------------- 375.00 PF 00100003112300 PLAN CHECK FEES 1,500.00 PP 00100003111100 PLUMBING PERMIT FEES 3 .00 WC 00100003112800 WILL CALL INSPECTION FEE ------------------------ APPLZCATION WILL NOT BE ACCEPTED iF iNCOMPLPEr�eCt#N��'�-g�� - a�? 3 Building Permit #: � - �r�c� � Plumbing Permit #: ' �i � Q � 970-479-2149 (Inspect ns) ��� E � ����� 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL PLUMBING PERMIT APPLICATION CON�RACTOR INFORMATION Town of Vail Reg. No.: Contact Person and Phone #'s: Piumbing Contractor: �14_ � ������ c�VC.r-��-�� 7U a�C�i�l h,vo►v �I��M�+tiG , ��• Fax#: 7�����15 E-Mail Address: Contractor Signature: `�``G�.� ��G� COMPLETE VALUATION FOR PLUMBING PERMIT (Labor &Materials) -. ,� �o PLUMBING: $ �'�U-�� ntact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www,ea le-coun ,com for Parce/# Co Parcel # ]ob Address: ��C�� ]ob Name: '�O���.-�1� �Ll� `�-C� 4�7 ��te�M�l D� C Legal Description Lot: Block: Filing: Subdivision: ddr s�;, Phone: -3p�-��� - �316 � Owners Name: -�,��?-rNE�;t ��..>�t. ����� t�v�.,"�.r�v�2 �2� �;-�e�n�i°si °f C'���.- Phone: Engineer: Address: Detailed description of work: ��������' 1.�E� CCt.�C��2i�C'_�'(I C� - �L'c�l"((��c T� Work Class: New ( v� Addition ( ) Alteration ( ) Repair( ) Other( ) Type of Bldg.: Single-family( ) Duplex ) Multi-family( ) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: ********************�*****��***********FOR OFFICE USE ONLY*�**�**�************�*******�*�**�*** Other Fees: Date Received: " Acce ted B :; � I �� V � F:\cdev\FORMS\PERMITS\Building\plumbing_permit_l 1-23-2005.doc Page 1 of 1 11/23/2005 __ _ ._ . +�, .. 08-20-2008 Inspection Request Re orting Page 43 4:53 m Requested Inspect Date: Thursday,August 21, 2008 Inspection Area: CG Site Address: 4367 STREAMSIDE CR,Un�ts 5&6 A/PID Information Sub Type: NDUP Status: ISSUED Activity: 606-0119 Type: 6-B�� Use: V-B Insp Area: CG Const Type: 103 OccupancY. Phone: 303-327-8161 Owner: STREAMSIDE CIRCLE PARTNERSHIP LLLP Phone: 970-949-5152 Contractor: R.A. NELSON &ASSOCIATES, INC Description: NEW CONSTRUCTION OF A DUPLEX AND SITE IMPROVEMENTS TRILOGY UNITS 5 AND 6 Requested Inspection(s) Requested Time: 02:00 PM Item: 540 BLDG-Final CIO Phone: 970-949-5152 Requestor: R.A. NELSON &ASSOCIATES, INC Comments: Will call John 471-6048 Entered By: DGOLDEN K Assigned To: JMONDRAGON Time Exp p IN FILE Action: INSPECTION RECEIOE'6XN Comment: � j ; �,.-'''� , ��� 1� ��-� f p J ���,, �'� � f- ;j ' �� r t f +f;" l ; ��-�- ,r�� 1 �,_� ; ..� r �� - �f`� '�-%' � - j ,% � � �$ �; n.,� P''�` , ��`� �� � ` , Inspection Historv �. �/ ,�� ' Item: 502 PW-Rough grade ' Item: 503 PW-FinaT drivewa�grad�oved"` Action: AP APPROVED � Item: 10 BLDG-FOOTING �App 08/03/06 Inspector: JEC ' Comment: Apv'd footings&pads Action: AP APPROVED 09/12/06 Inspector: JEC Comment: APPROVED RE P�CEMENT GS. LETTER ATTACHED FROM R NSPECTIONR WALL REMOVAL& RE Action. NR NOT READY FO 12/22/06 Inspector. GCD Comment: Action: AP APPROVED 12/26/06 Inspector: GCD Comment: 2 FADS AND 2 PIERS Item: 20 BLDG-Foundation/Steel Action: PI PARTIAL INSPECTION 08/21/06 Inspector: shahn ara e. Comment: foundation walls per�revirovedetail on file; excluding g 9 Item: 21 PLAN-ILC Foundation Plan PP Action� rova APPROVED 01/25/07 Inspector: b ibson ' Comment: inadequate in�ormation for framing ILC app ' Item: 30 BLDG-Framing Action: DN DENIED ' 01/26/07 Insp ector. GCD ' Comment: ILC REQD TO BE SUBMITTED TO ActionNl CR CORRECTIONAREQUIRED 01/31/07 Inspector. GCD Comment: UN1T 6 2.PROVIDE ASABUSLT FOR ROOF FRAMI�NGNN MAST�ER BATHEVIEW AND FIX. 3.PROVIDE FULL BEARING AT MANGERS MASTER CLOSET. 4.PROVIDE CLARIFICATION OF 5.5 LVL IN MASTER CLOSET. � 5.HAVE ENG REVIEW BORED HOLES IN LVL BEAMS. 6.HAVE ENG REVIEW MISSING LVL STUDS AT CORMER OF GREAT ROOM WINDOW. 7.FIREPLACES REQ INSPECTION. 8.SUBMIT REVISED STRUCTURAL PLANS TO TOV FOR REVIEW. NO INSULATION UNITL REVISIONACA�PPRPI PARTIAL INSPECTION 03/05/07 Inspector. GCD ' Comment: UN1T 6, ETILL REQSRNSPECTION PRIOR TO GYPS �'2'4'5,6, ITEM ITEM 3 IS APPROVED. ITEM 7 S Run Id: 8383 REPT131 , ----__--- ----- - _ ____ 11-15-2007 inspection Request Re orting Page 84 4:16 m Requested Inspect Date: Friday,November 16,2007 Inspection Area: SH Site Address: 4367 STREAMSIDE CR,Un�ts 58�6 AIPID Information Sub Type: NDUP Status: ISSUED Activity: E06-0130 Type: B-ELEC Use: Insp Area: SH Const Type: Occu ancy: Owner: STREAMSIDE CIRCLE PA�TNERSHIP LLLP phone: 970-468-6166 Contractor: PATTERSON ELECTRIC CO Description: ELECTRICAL FOR DUPLEX Re4uested Inspection s Requested Time: 08:00 AM Item: 190 ELEC-Final Phone: 3310 68-6166 -or- 418- Requestor: PATTERSON ELECTRIC CO Comments: Bldg 3 #5 &6 Entered By: DGOLDEN K Assigned To: SHAHN Time Exp: _— Action: . � ��� CJf � , �- Insaection Historv Item: 110 ELEC-Service '"Approved*" Action: AP APPROVED 07/18/07 Inspector: shahn Comment: **qPproved*' Item: 120 ELEC-RouAh Action: AP APPROVED 11/09/06 Inspector: shahn Comment: done by emst.5/6 wiring in roof as Ac ion� PI PARTIAL INSPECTION 01/25/07 Inspecfor: shahn Comment: unit 6 ROUGH ok.EC TO CONNECAction RAP APPROVED 02/22/07 Inspector: JEC Comment: #5 rou h apv d. UFER ground apv'dAction: AP APPROVED 05/24/07 Inspec�or: shahn Comment: MASTER CNOSET TO BE ARE�FAULTSPECT LOWER BATH AND UPPER MASTER. BSEMENT AND BATH OK **A roved""' Action: DN DENIED Item: 130 ELEC-Conduit PP 02/14/07 Inspector: JEC sical damage.Schedu e Comment: &352 a2���eSC�hedule 40SShnotuULBlsted o�r�use where sub1 ect to phyf house.NEC 352.10(F 80 is UL listed for use where subject to ph sical damage.Marlcing on nser had been removed� giving what schedule conduit was.NA�tion�AP A�PPROVED 02/22/07 rnspector: JEC Comment: Schedule 40 PVC changed to Schedule 80 Item: 190 ELEC-Final Rua Id: 7241 REPT131 � 11-20-2007 Inspection Request Re orting Page 61 4:23 m Requested Inspect Date: Wednesday, November 21,2007 Inspection Area: CG Site Address: 4367 STREAM3IDE CR UNITS 5 AND 6 AIP/D Information Sub T e NDUP Status: ISSUED Activiry: M07-0013 Type: B-MECH yp � Insp Area: CG Const Type: Occupanc . Use: Owner: STREAMSIDE CIRCLE PARTN RSHIP LLLP Phone: 970-928-8758 Contractor: FIRE WORKS HEARTH&PATIO, INC Description: INSTALL 2 FIREPLACES IN EACH UNIT Re4uested Insaection(sl Requested Time: 02:00 PM Item: 390 MECH-Final Phone: 970-471-4822,SPENCER Comments: UNIT#5R W�TH RA NELSON Entered By: LCAMPBELL K Assigned To: GDENCKLA Time Exp: __ Acfion: � (e ,'� �.."��L�f / 1 �• 4 �, {, Insaection Historv Item: 200 MECH-Rough "Approved""` Action: CR CORRECTION REQUIRED 03/20/0T Inspector: GCD Comment: p STANCE MAIN�P REPAIR FLEX CONNECTOR GE 19 TO HORIZONTAL TO VERTICL UNIT 5 MAIN FP OUTSIDE AIR NOT INSTALLED. DEN FP APPR Action: COND APPROVED/CONDITIONS 03/21/07 Ins pector: GCD Comment: REPAIRED E�ER FROM HEAT&GLO REGARDING VENTING OF SL550. FLEX DUC UNIT 5 AIR KIT INSTALLED. Item: 310 MECH-Heating. Item: 315 PLMB-Gas Pipin�g Item: 320 MECH-Exha�sANoods Item: 330 MECH-Supp y Item: 390 MECH-F nal Run Id: 7248 RTPT131 �_ � � 08-20-2008 Inspection Request Re orting Page 70 4:53 m Requested Inspect Date: Thursday,August 21,2008 Inspection Area: CG Site Address: 4367 STREAMSIDE CR, Unl ts 5&6 AIPID Information Sub Type: NDUP Status: ISSUED Activity: M06-0154 Type: B-MECH �Se: Insp Area: CG Const Type: Occupanc . Owner: STREAMSIDE CIRCLE PARTN RSHIP LLLP Phone: (970)328-2699 Contractor: R&H MECHANICAL LLC Description: BASE BOARD RADIANT HEAT Reauested Insaection(sl Requested Time: 03:00 PM Item: 390 MECH-Final Phone: (970)328-2699 Requestor: R&H MECHANICAL LLC Entered By: DGOLDEN K Assigned To: JM�IONDRAGON 1-6048 Action: Time Exp: `— a, Comment: �� � ,r`,---�� ��,'" � r`!�.%�� �t�� .� �-t_�"'�' e y � � ,, ,�'� ,, ' ,��� �} � ; r � i ✓�,/', i � � J 1, ��� ,� f ,f�; \'j f/� V Inspection Historv Item: 200 MECH-Rough **Approved"" Action: DN DENIED 06/26/06- Inspector: JRM ' Comment: FEES STIL DUE Action: CR CORRECTION REQUIRED 12/29/06 Inspector: SHAHN Comment: EAST SIDE(UNIT 6) PROVIDE SECONDARY LINT TRAP FOR DRYER BOOSTER AS REQUIRED BE KITCHENCHOQD NOT INSTALLED AT ROUGHTCAN L�FOR REINSPECTIONCTION. , INSPECTED 2 BOILBEEN INSTACLDED ON TYP�B VEN�BOILERS INSTALLED. NOTE TAH 3 90 ELBOWS HAVE INSPECTED 7 BATH FANS. PIPE INSULATION REQUIRED PEAction CR CORRECTION REQUIRED 01/08/07 Inspe� ctor: SHAHN ' Comment: #5 NEEDS REINSPECT GUEST BEDROOM MISSING BATH FAN HYDRONICS 100#AIR OK RADIANT 100#AIR OK SNOWMELT 100#AIR OK 01/08/07 Inspector. SHAHN Action: PI PARTIAL INSPECTION ' Comment: #6 CORRECTIONS OK Action: AP APPROVED 01/10/07 Inspector: SHAHN C05/09/0 �n�peRtoCTlO Cp OM 01-08-07 APARIOnE NR NOT READY FOR NSPECTION Comment:. Item: 310 MECH-Heating Action: NR NOT READY FOR INSPECTION 05/09/07 fnspector. GCD Comment: ' Item: 315 PLMB-Gas Piping Item: 320 MECH-Exha�sAHoods Item: 330 MECM-Supp y Item: 390 MECH-Final *`A proved"" Action: PA PARTIAL APPROVAL Com�me�t OK FORrTCOC� _ �� — ---Run Id: 8383 REPT131 11-20-2007 Inspection Request Reporting Page 73 4'23 pm Vailr CO - Citv Of Requested Inspect Date: Wednesday, November 21,2007 Inspection Area: CG Site Address: 4367 STREAMSIDE CR VAIL 4367 Streamside Cr,Units 5&6 A/P/D Information Activiry: P06-0083 Type: B-PLMB Sub Type: NDUP Status: ISSUED Const Type: Occupancy: Use: Insp Area: CG Owner: STREAMSIDE CIRCLE PARTNERSHIP LLLP Contractor: AVON PLUMBING&HEATING Phone: 970-748-0944 Description: TORZETfO BLDG 5 8�6-COMPLETE PLUMBING Reauested Insaection(s) Item: 290 PLMB-Final Requested Time: 11:30 AM Requestor: AVON PLUMBING&HEATING Phone: 904-0091 Comments: bldg.5 Assigned To: GDENCKLA Entered By: DGOLDEN K Action: Time Exp: Comment: . TOR REQD TO OPEKATE-f1�AUT0 MODE. 2.MASTER SHOWER NO HOT WATER ���}{�"�7�� ) f d lJ � ! i,3 r'� Inspection Historv Item: 210 PLMB-Underg round *'Approved'"` 09/01/06 lnspector: shahn Action: AP APPROVED Comment: Underg round approved for bld�5&6. Item: 220 PLMB-Rough/D.W.V. "'Approved 12/29/06 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: EAST SIDE(UNIT 6)DWV 5#AIR TEST. NOTE THA7 SEWAGE LIFT NOT INSTALLED A THIS TIME. 01/05/07 Inspector: shahn Action: APCR APPROVED/CORRECTION REQD Comment: WEST: DWV TEST WAS 7#AIR-OK. EAST AND WEST:CORRECTION:AFTER 2 SITE VISITS IT WAS DETERMINED THAT THE SEWAGE EJECTOR CONNECTION TO BUILDING SEWER DOES NOT COMPLY WITH IPC 712.3.5.(MINIMUM 10FT FROM THE BASE OF ANY SOIL STACK,WASTE STACK, OR FIXTURE DRAIN). EJECTOR DISCHARGE PIPING NOT INSTALLED AT INSPECTION. 01/15/07 Inspector: SHAHN Action: AP APPROVED Comment: ROUGH FOR SEWAGE EJECTORS APPROVED BOTH UNITS 5&6. Item: 230 PLMB-Rough/Water "'Approved'* 12/29/06 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: EAST SIDE(UNIT 6)DOM WATER 100#AIR TEST FOR COPPER. 01/05/07 Inspector: shahn Action: AP APPROVED Comment: EAST SIDE BLDG 6: DOM WATER 100PS1. Item: 240 PLMB-Gas Piping ''"Approved*'" 01/12/07 lnspector: shahn Action: AP APPROVED Comment: BUILDING#5 AND#6 GAS PIPING OK. 16#AIR IN BOTH UITS.BLACK PIPE USED THROUGHOUT. Item: 250 PLMB-Pool/Hot Tub Item: 260 PLMB-Misc. Item: 290 PLMB-Final 11/19/07 Inspector: GCD Action: CR CORRECTION REQUIRED REPT131 Rua Id: 7248