Loading...
HomeMy WebLinkAboutDRB18-0582_approved plans_1544724986.pdf lei OF fr. sh R . d ____, DRB APPROVED 12/13/2018 12:00:00 AM 4682 MEADOW DR . # 1 VAIL , COLORADO 81658 PROJECT DISCRIPTION : PROJECT TEAM : THIS PROJECT INVOLVES INTERIOR RENOVATION OF AN EXISTING TOWN HOME AT THE MEADOW DESIGNER: MOUNTAIN TOWNHOME COMPLEX IN THE EAST VAILNEIGHBORHOOD OF VAIL, CO. BURKW HARRINGTON CONSTRUCTION PO BOX 2953 PROJECT INCLUDES NEW FINISHES THROUGHOUT. VAIL, CO 81658 ADDITIONALLY THERE WILL BE SOME MINOR BHCCO@COMCAST.NET STRUCTURAL AND INTERIOR WALL MODIFICATIONS PHONE: 970-376-2256 AS WELL AS RELOCATION OF GAS, PLUMBING AND ELECTRICAL SERVICES WHICH WILL ALL BE CONTACT: MBURKE HARRINGTON PERMITTEDSEPERATELY BY THE RESPONSIBLE TRADESMEN. THE EXISTING WOOD BURNING STRUCTURAL ENGINEER: FIREPLACE IS TO BE REMOVED AND REPLACED KRM CONSULTANTS WITH A NEW GAS APPLIANCE. AS THERE IS A PO BOX 4572 CRAWL SPACE WITHIN THE UNIT ACCESS TO SERVICES AND THEIR RELOCATION WILL NOT VAIL, CO 81658 REQUIRE DIGGING OR EXCAVATING. ALL WORK IS PHONE: 970-949-9391 TO BE WITHIN THE RESIDENCE WITH NO EXTERIOR CONTACT: TIM HENNUM WORK REQUIRED. 9'-112" 15'-6q" -/ -/ /- CONTRACTOR: PROJECT INVOLVES CANTILEVERING THE UPPER BURKW HARRINGTON CONSTRUCTION \ 9'-0"X7-0" — \ LEVEL OFFICE AREA INTO THE DINING AREA 8'11 CEILING SPRING PT. ADDING 21 SQ-FT. OF USEABLE FLOOR SPACE TO PO BOX 2953 THE UNIT. THIS IS DONE ENTIRELY WITHIN THE VAIL, CO 81658 EXISTING BUILDING ENVELOPE WITH NO EXTERIOR BHCCO@COMCAST.NET MODIFICATIONS. SEE PAGE A103. PHONE: 970-376-2256 CONTACT: MBURKE HARRINGTON 13'-6" 11'-74"/ / DRAWING INDEX : OWNER N N 10'-8"CH @ PEAK 7'-0"CEILING SP JON AND CAROL SHANSER I I I ARCHITECTURAL I A 101 COVER PGE AND EXISTING CONDITIONS JONSHANSER@GMAIL.COM 0 7'-7" CEILING SP PHONE: 415-259-7878 ` I I A 102 DEMO PLANS PO BOX 2910 �� A 103 CONSTRUCTION PLANS A 103.5 FINISH PLANS OLYMPIC, VALLEY,CA 96146 N – 71in 8'-6" CH o BEDROOM2 A 103.75 ELEC. PLANS �° GARAGE 6 A 104 KITCHEN DETAILS =1M A 105 BATHROOM DETAILS j z 13"x6" 7'10"AFF CEILING BEAM A 106 LIVING ROOM DETAILS in MASTER BEDROOM BEDROOM 1 CEILING TYP.8' STRUCTURAL MOUNT CEILING HTS. N HEAT S I FRAMING PLANS i� W O 6" STEPX \ o 10'-4"CEILING LINE I I— 30°? o / CLOSET 0 / in CEILING TRANS LAUNDRY 6 -=, /` O t+),� _� \ 30'? r _ 8' CEILING HT AT 7' (/) H2O = \ J I CLOSET AND `, W PANEL 1 A _ BATHROOMS PANEL H 1\ 0 30'? `L =_ \\ I 03 \ z 30" MASTER SD dN CLOSET MASTER N BATH 1 —�� o ' - BATH GENERAL NOTES: GENERAL CONSTRUCTION NOTES: O N01BATH 2 © ~ CLIENT: JON AND CAROL SHANSER. • VERIFY ALL DIMENSIONS PRIOR TO 12" TALL SOFFIT HALL = �••••,at•!►•i F. • JONSHANSER@GMAIL.COM 415-259-7878 STARTING CONSTRUCTION. Et 7C A coi) KITCHEN �•..i...•1 o ALIGNING WITH ED �� UPPER CABS. • CSHANSE@GMAIL.COM 415-259-7877 • NEW FLOORING THROUGHOUT. I- O — •'�%� \ •CU • PROJECT IS AT MEADOW MOUNTAIN • PRICE NEW WALL AND CEILING TEXTURE Lu = 0 CLOSET � TOWNHOMES IN EAST VAIL. UNIT CALLED THROUGHOUT. w OD < STAIR 0 OUT AS 4A BUT IS TECHNICALLY 1. • NEW PAINT THROUGHOUT. 0 _ % 0 z 24" / - - J • CLIENTS CURRENTLY LIVE PARTTIME • ALL NEW INTERIOR DOORS, CASING AND o i I // ////////// ///// ACROSS THE STREET IN VAIL RECQUET TRIM THROUGHOUT. CLOSET Q O U ENTRY \ / CLUB. • NEW FIRPLACE APPLIANCE, HEARTH AND 0 J i i • BUILDER: BURKE HARRINGTON CONST. SURROUND. ,� �� / � � � y� \ P.O. BOX 2943 • DEMO EXISTING STAIR WALL TO SLIGHTLY C VAIL, CO 81658 ABOVE TREADS AND ADD 1, 3'-10" jr 7'- " 970-376-2256 HANDRAIL/GUARDRAIL AT STAIR WALLS, 10'-4" 3'-10" 7'_44" / BHCCO@COMCAST.NET SEE DETAIL. M • ENGINEER - KRM CONSULTANTS • PROVIDE FOR NEW POST AT CORNER OF PROJECT : - ). /\ A= 0 0 970-949-9391. STAIR IN LIEU OF WALL TO BE REMOVED. DRAWN B Y : - ' • PROVIDE FOR NEW KITCHEN AND DATE LIVING DINING - _ APPLIANCES. • REFINISHING OF 3 BATHROOMS. REVISIONS _ _ • RE-CONFIGURE MASTER CLOSET. M o • RELOCATE WATER HEATER TO GARAGE CLOSET. M O O 7c2,, 0 0 O ti� Ty EST. 12' CH SP THIS WALL IJ • I I 1EXISTING FP 3'-6"X 32"WOOD EST. 12' CH SP THIS WALL CONDITIONS BURNING UNIT W/ WOOD SURROUND FLOOR TO CEILING. EXISTINGCONDITIONSUPPERLEVEL A101(1 )EXI3TINGC0NDITI0NSL0WERLEVEL 1/4"= 1'-0" 2 1/4"= 1'-0" �„ GENERAL CONSTRUCTION NOTES: KEY NOTES: ` S C 9' 11Z 15'-641" VERIFYALL DIMENSIONS PRIOR TO 1. NEW RECESSED PANTRY SHELVES. IfSTARTING CONSTRUCTION. NEW LIGHT IN PANTRY ON JAMB • NEW FLOORING,TEXTURE AND PAINT SWITCH. STAIN SHELVES TO MATCH 93 8'11 CEILING THROUGHOUT. KITCHEN CABINETS. "170) lir SPRING PT. • ALL NEW INTERIOR DOORS,CASING 2. PROVIDE NEW GAS SUPPLY FOR NEW DRB AND TRIM THROUGHOUT. STOVE. APPROVED 12/13/2018 • NEW FIRPLACEAPPLIANCE,HEARTH 3. NEW CLOSET DOORS. NEW LIGHT ON 12:00:00 AM AND SURROUND. JAMB SWITCH. • NEW GUARD AND HANDRAILS AS 4. NEW 24" POCKET DOOR. 13'-6" 11'-74" NOTED. STYLE TB D 5. LINE OF NEW FLOOR ABOVE. /- • NEW STRUCTURAL FRAMING PER 6. LOCATION OF NEW B ENCH WITH STRUCTURAL PLANS. HOOKS AB OVETB D. • PROVIDE FOR NEW KITCHEN AND 7. RELOCATE HOT WATER HEATER TO N 7'-0"CEILING SP APPLIANCES. GARAGE CLOSET. PROVIDE NEW ry 10'-8" CH @ PEAK I L� • I • REFINISHING OF LOWER LEVEL GAS LINE. — BATHROOM. 8. DRAWER SYSTEM FOR BOOT/SHOE 7-7"CEILING SP • RECONFIGURATION OF UPPER OR OTHER STORAGE. BATHROOMS. 9. NEW TECH LIGHTING LOW VOLTAGE O •• RE-CONFIGURE MASTER CLOSET. SYSTEM HUNG FROM CEILING. 7 RELOCATION OF WATER HEATER TO 10. RELOCATE SINK DRAIN AND SUPPLY (N) GARAGE CLOSET,AND CONVERT TO LINES. INCLUDE NEW ELECTRICAL H2O in — BEDROOM2 GAS. FOR DW,AND INSTANT HOT WATER — 718' 6" CH o • EXTEND LL CLOSET WALLS TO SYSTEM. 6 CEILING. 11. PROVIDE NEW TOILET,TUB TILE GARAGE uO - 0J N • RAISE CEILING HT LL BATH SURROUND,SHOWER VALVE,VANITY, __- 0 M 0 • ELEC. OUTLETS AT ALL TOILET LIGHTS AND FINISHES. ,I 13"x6" 7'10" AFF LOCATIONS. 12. EXTEND CLOSET WALLS TO CEILING. _ -IN CEILING BEAM • PROVIDE NEW 220V LINE AT GARAGE 13. NEW OFFICE AREA WITH PARTIAL HT. N TO PREPARE FOR FUTURE ELEC. WALLS,NEW CEILING STRUCTURE CEILING VEHICLE. PER STRUCT.AND INT. ELEVATIONS. OUNT HE'T • PROVIDE FOR HOT H2O DISPENSER IN NEW 22" DEEP DESK AT 30"AFF. NEW (E) MASTER B EDROOM KITCHEN. PARTIAL HT WALL @38". --- W • PROVIDE FOR CEILING FANS IN 4'-64" LIVING ROOM, MASTER AND GUEST t / 10'-4" CEILING LINE BEDROOM1 BEDROOMS. • zzr --_ 6" STEP © X •y 1 I • • NEW THERMOSTATS THROUGHOUT, I • Jr 3'-9a" 3'-6" 3'- HEATERS AS RECOMMENDED. •— 30"? No I (CEILIGTRANS M� ALL NEW SWITCHES, OUTLETS AND y =,q Mia PLATES THROUGHOUT, IVORY FINISH. W "' °� 30°? 00 • PROVIDE GAS SUPPLY TO WATER z LAUNDRY ,a CLOSET 8' CEILING HT AT 0 r N N r HEATER,FP AND STOVE LOCATIONS. -- ,� \ w LI] CLOSET AND • PROVIDE NEW HOT WATER m=1 H O BATHROOMS RECIRCULATING SYSTEM. PANEL I aN o w U BATH2 • • TILE BASE AT BATHROOM 1 1 \ `�' © z z ___ LOCATIONS. ® 30"7 a�. I 24 14 \ - CO a S D Q z al M 30" TYP.8' • MASTER MASTER U BATH 1 e t CEILING HTS. CLOSET BATH ` "0 CABS. --- SHOWER --- N 11 12" TALL SOFFIT o o - En ALIGNING WITH UPPER 0 ,-- ,__ Ao v 77 I — (lial KITCHEN .. .. / 3'-4 / 'z va10 / m 0 SHOWER olio0 77 PANTRY 2 .. `" — STAIR • --- DEMO WALL / F . .1„ , - + 2a TLOANDP OF — 21 SQ-FT. USEABLEAREA ADDED TO o �a — M / ® 0 J I RESIDENCE VIA CANTILEVER.NO zl- o EXTERIOR MODIFICATIONS READ. —ENTRY // / 3'-10" / 7'-W" / 13 ' \ L\ \, \\\7\:\\\\ \ , \\\ \\ it' 0 \o�o0000000000000 `00000000•��O\����\' \:�O�pOo••\\\�\���''‘\\\"p\�\\' ,— 5 0 10 q - ��. r �� co 36" PT. HT. Co 12 `� / WALL TYP. A N • IIII 10'-4" 3'-10 OADBEARING _ \ POST 0EW POST STRUCTURAL.PER PER STRUCT. NEW GUARDRAIL MIN. 36"AFF NOT TO ALLOW 30° PASSAGE OF A 4" c SPHERE m DINING m Mla N LIVING x>c76),, ��; - - 0 C� 'A�, m z y9pA'�'j T 9�0 i� ci) c.� '90 �� ��,� I 1 0 I i 15 EST. 12' CH SP THIS WALL z I- 0 A CONSTRUCTION PLAN LOWER LEVEL •CONSTRUCTIONPLANUPPERLEVEL w z o 1/4"=1'-0" 1/4"= 1'-0" O ZC < O O PROJECT : - DRAWN BY : - DATE : - REVISIONS : 1 ONSTRUCTIO PLANS +OOFfr N-../ TIg 13 #kip 7/ PANEL DRB F141�0 APPRO ED 12/13/20 8 12:00:00 AM 30"? _ - - - I II II � = o POTS iii 0 30" N I II O TYP. 8' s _ - - - - � „iII z 0 CEILING r gum- Fi ^ I) m 0 M I I I I L OPEN 3'-12�� 22'-7'� .,-- ---) -,r � /- 12" 1 ALIO LEDGE /-0-\\•'.00• - DESK NEW EXTENSION OF �/1► /►� N CAB CLOSET ALLS I 14 NI KITCHEN i:!P• ! 24" D 1--1 * m FLOOR SYSTEM m SOFFIT SOFFIT SOFFIT 5'_°Li 0 0 C T MICRO. ■ - - - - - - LOC. I III IIIW I I III 111= 111 C 01 DW III IIIm pToRApE - FRIDGE C - _ 111 0 IIIm 0 1 I III I I I-1 111 I1 LOC. M JJ , LLL( LLL 11 C" ) C _ C - ] DW C C POTS SINK BOX LOC. DRAWERS 30" SINK C r r M C C • I ALT. DW LOCATION EAST KIT. ELEV. WEST KIT. ELEV. 1 2 1/4"= 1'-0" 1/4"= 1'-0" 3 1/4"=1'-0" Cw 0 // 2z / O I- z Q BEDROOM2 BATH - OFFICE LIJ z a I zoo Qoo = Q -1-- (f) L .1 < PROJECT : - SOFFIT DRAWN BY : - DATE : - HOOD SYSTEM REVISIONS : LIVING/DINING KITCHEN BAR GARAGE LAUNDRY 1 I iI I MAGIC CORNER RANGE DW WARMING BUFFET LOCATION DRAWER DESK KITCHEN DETAILS 4 SOUTH KIT. ELEV. A104 1/4"= 1'-0" of lF z'4, I i 1n 4 -64 X03 CPT \ 1120D P , , Li I TILE ` DRB APPRO ED 12/13/20 8 12:00:00 AM = W 1 - y CEILING TRANS ANS o - �1 3o"? , Co c2,..--kr _� CLOSET - 8' CI `� N y W 0 * _ J w CLC DRESSER y 3.. 1.. BAT SS 30"? 1 -114 =112 3'-6" 3'- 9:: V) OJ BATH 2 • // 4 24" - W C.) \\ / --- M �/ z z 30" 3'-4f 3'-42" O m W BATH 1 —i * / / S SD ` U J M G ZY) I= O - m MASTER 111 CLOSET SHOWER ti 0 C-6-- o • \/ r PANTRY - I I STAIR c 0 -\ \/ 2'-104„ 4'-1 POWDER ROOM PLAN •MASTERBATH —/ /—/1/2"=1'-0" 1/2"= 1'-0" 0 BATH #2 1/2"=1'-0" 1 I 8 TO MASTER MASTER TO OWNER 4) BATH CLOSET CLOSET SYSTEM W 0 2 Z O I- Q 2 MASTER BATH ELEVATIONS w Z 0 Z ° O Q 0 U Z Q J n '- ' •g PROJECT : - ° DRAWN BY : - 8 DATE : - o o REVISIONS : cf 0 0 BATHROOM DETAILS 2 POWDER BATH ELEVATIONS A105 1/2"= 1'-0" of F c ° " APPROVED 12/13/2018 12:00:00 AM _ N C rn N Io O) O -0 TI- ( .4; D .. �O C O N a NO) a7 H Z < •• Q Lai L J N N D C (n Z c iiiffi ii _- m'si lim O N Ln STL. BM. PER PLAN 2 � Nm - ao (2)—Y2"0x6" LAGSo 0 m BUILT—UP STUD COL. PER PLAN --.__ _ /i .47,%<?? SCALE: 3/4" = 1'-0" <, ¢o .Silia taz=.! ID ., is®Arra, ® og N 10/26/2018 s I7II ® I� Y2�� F I Dc I / J L_4x4xY4x0'-5Y2" co co 1 1 v.2 ��1� 11 3 13%x9) �� W8x15 r -[I _ -L (E) BM I I ( )— LVL �— (DROPPED) N sec,' (E) If PER ARCH 1 Eli (N) 2x10's © 16" O.C. �� i_I i ,a I I SIMPSON I ii 4 1--4 II LB210, TYP. II I I O1 III I (E) BM LL , i L T eikke,07) I I I 4 ' rte' I CONTACT ENGR. TO rTI ► REVIEW CRAWLSPACE & FOUNDATION H DURING CONSTRUCTION H I I I Z I I I figliH LL � � J NORTH I t I z t I t J 1 Cr3 .T4 UPPER FLOOR LOW ROOF FRAMING PLAN SCALE: 1 /4" = 1 '-0" „oiepipion NORTHI ,mil ROOF FRAMING PLAN SCALE: 1 /4” = 1 —0 vols' blio PLAN NOTES FOR NEW FRAMING: — PLAN NOTES FOR NEW FRAMING: 1. NEW POSTS BELOW (ORIGINATING FROM THIS LEVEL OR ABOVE) ARE INDICATED: ❑ NON—CONTINUOUS POSTS FROM ABOVE ARE INDICATED:® 1. NEW POSTS BELOW (ORIGINATING FROM THIS LEVEL OR ABOVE) ARE INDICATED: ❑ NON—CONTINUOUS POSTS FROM ABOVE ARE INDICATED: 2. ALL POSTS ARE LABELED AT THE TOP. 2. ALL POSTS ARE LABELED AT THE TOP. 3. NEW FLOOR SHEATHING IS 3/4" TONGUE AND GROOVE APA STURDIFLOOR, EXP.1, SPAN RATING 24 O.C. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR ORDERING STRUCTURAL ELEMENTS (INCLUDING LEAD TIME) TO ADHERE WITH THE designed by TDH 4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ORDERING STRUCTURAL ELEMENTS (INCLUDING LEAD TIME) TO ADHERE WITH THE SCHEDULE OF PROJECT. STW SCHEDULE OF PROJECT. drawn by 5. EXISTING CONSTRUCTION (E) IS INDICATED THUS ( ), NEW CONSTRUCTION (N) IS INDICATED THUS ( ) 4. EXISTING CONSTRUCTION (E) IS INDICATED THUS ( ), NEW CONSTRUCTION (N) IS INDICATED THUS ( ). MTN checked by 5. ROOF DESIGN LIVE LOAD=100 PSF issued 6. FLOOR DESIGN LIVE LOAD=40 PSF DEAD LOAD=15 PSF DEAD LOAD=15 PSF PERMIT 10/26/18 sheet \l JOB #1809- 18