HomeMy WebLinkAboutM03-0123TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT
Job Address: 75 S FRONTAGE RD WEST VAIL
Location.....: 75 S FRONTAGE RD MUNICIPAL BLDG
Parcel No...: 210108236004
Project No
OWNER TOWN OF VAIL
C/O FINANCE DEPT
75 S FRONTAGE RD
VAIL CO 81657
License:
CONTRACTOR LUNSFORD BROS. MECHANICAL
2481 COMMERCE BLVD
GRAND JUNCTION CO
81505
License: 127-M
APPLICANT LUNSFORD BROS. MECHANICAL
2481 COMMERCE BLVD
GRAND JUNCTION CO
81505
License: 127-M
07/21/2003 Phone:
Permit #: M03-0123
Status ...: ISSUED
Applied..: 07/21/2003
Issued. .: 07/22/2003
Expires . .: 01/18/2004
07/21/2003 Phone: 970-242-5790
07/21/2003 Phone: 970-242-5790
Desciption: REPLACE EXISTING BOILER WITH NEW
Valuation: $48,000.00
Fireplace Information: Restricted: Y # of Gas Appliances: 0 # of Gas Logs: 0
Wood Pellet: 0*** - - - - - - -????? FEE SUMMARY ....x ?., ..........._..?:?? ?? ? ?...??
Mechanical--> $960.00 Restuarant Plan Review--> $0.00 Total Calculated Fees ---> $1,203.00
Plan Check --- > $240.00 DRBFec > $0.00 Additional Fee:: >
$1,203.00)
Investigation-> $0.00 TOTAL FEES--------------> $1,203.00 Total Permit Fee >
$0.00
Will Call---> $3.00 Payments > $0.00
BALANCE DUE > $0.00
Item: 05100 BUILDING DEPARTMENT
07/21/2003 DF Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER SEC. 701 OF THE 1997 UMC, OR SECTION
701 OF THE 1997 IMC.
Cond: 23
(BLDG.): INSTALLATION MUST CONFORM TO MANUFACTURES INSTRUCTIONS AND TO CHAPTER
10 OF THE 1997 UMC, CHAPTER 10 OF THE 1997 IMC.
# of
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 8 AND SHALL
TERMINATE AS SPECIFIED IN SEC.806 OF THE 1997 UMC, OR CHAPTER 8 OF THE 1997 IMC.
Cond: 29
(BLDG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CHAPTER 3 AND SEC.1017 OF
THE 1997 UMC AND CHAPTER 3 OF THE 1997 IMC.
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): DRAINAGE OF MECHANICAL ROOMS CONTAINING HEATING OR HOT-WATER SUPPLY
BOILERS SHALL BE EQUIPPED WITH A FLOOR DRAIN PER SEC. 1022 OF THE 1997 UMC, OR
SECTION 1004.6 OF THE 1997 IMC.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an
accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and
plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning
and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable
thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM.
SIGNA URE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEI
07/17/2003 15:01 FAX
[a 002
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Project
Building Permit #:
Mechanical Permit #:
970-479-2149 (Inspections)
TOWN OF YAL
75 S. Frontage Rd.
Vail, Colorado 81657
TOWN OF VAIL MECHANICAL PERMIT APPLICATION
Permit will not be accepted without the following:
mensions
ean 5G1rvrqf& Layout drawn I
? Size and Lo
? and t? ? Sheets
CONTRACTOR INFORMA N
Mechanical
Lvl rc?,
E-Mail Address:
Town of V2
_
mwa onu rnone *-5; `?16
Contractor Signature:
COMPLt ii r VALLTION FOR MECHANICAL PERMIT (Labor & Materials)
MECCAL: $ r 1 T?
-'- .
c tact & Jfe CO &Assessors Office alt 970-329-8640 or visit www. eag/e county, com for Parcel #
?i?rc
ei # l 5c.`? bu ter- ?'
-
LI)b' (Job Address: f
C? •? N\on 1 c i l?4 ( 1 d?. II ?? r?0 n?i'???d
Legal Description Lot: Block: 1 Filing: Subdivision:
Owners Name: ; J v Address: ?15 ? F;fbh+, P Phone:
C('??
En ineer: Address: ?
Ir r ?? Phone: 7U ' '
g h I?ZG ?? f
.
- -
..,.,
Detailed description of woIj 1 V c? - t? v o ?n
- `
?CLrY1Cj ? ?C
.
Work Class: New () Addition ( ) Alteration M Repair Other ( )
Boiler Location: Interior h Exterior ( ) Other (?) I I Does an EHU exist at this location: Yes( ) No(
)
Type of Bldg: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial Restaurant( ) Other(
)
No. of Existing Dwelling Units in this building; _ __ •? No. of Accommodation Units in this building:
No/Type of Fireplaces Existnq: Gas Appliances ( ) Gas Logs [ ) Wood/Pellet [ ) Wood Buminq [ )
rNp[Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED)
f
Is this a conversion from a wood burning fireplace to an EPA Phase l device? Yes ( ) No
************************FOR OFFICE USE ONLY*****************************
x4 ,, Accebtdd OV.• ;,I=-'.''
1„ DRB,'FeeS e . ' I .Date, Received: , ?
\\VbiJ\dulnkdevlFORMS\PF.RMTTS\MECHPERM,DOC 07/26/2002