Loading...
HomeMy WebLinkAboutE03-0012TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E03-0012 ko 3-v6 (I Job Address: 75 S FRONTAGE RD WEST VAIL Status . ..: ISSUED Location.....: 75 S FRONTAGE ROAD Applied ..: 02/07/2003 Parcel No...: 210108236004 Issued . .: 03/24/2003 Project No -V`q-5a3 -Ool Expires . .: 09/20/2003 OWNER TOWN OF VAIL 02/07/2003 Phone: C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 License: CONTRACTOR FALCON PLUMBING & HEATING 02/07/2003 Phone: v 3187 MESA AVENUE, SUITE A GRAND JUNCTION CO 81504 License: 175-P APPLICANT FALCON PLUMBING & HEATING 02/07/2003 Phone: 970-4 34-0556 3187 MESA AVENUE, SUITE A GRAND JUNCTION CO 81504 License: Desciption: ELECTRICAL WORK FOR NEW BOILER Valuation: $4,700.00 ********************************************************************* FEE SUMMARY ********************************_..__...******* . ................... Electrical > $90.00 Total Calculated Fees--> $93.00 DRB Fee > $0.00 Additional Fees-------> ($93.00) Investigation ---- > $0.00 Total Permit Fee > $0.00 Will Call > $3.00 Paymentc > $0.00 TOTAL FEES-> $93.00 BALANCE DUE > $0.00 Approvals: Item: 06000 ELECTRICAL DEPARTMENT 02/07/2003 DF Action: AP Item: 05600 FIRE DEPARTMENT CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEI APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Project #: Building Permit #: Electrical Permit #: A 970-479-2149 (Inspections) TOWN OFYAIL O07TRAC L L TRICAL PERMI PP I ON 75 S. Frontage Rd. Vail, Colorado 81657 !r OR INFORMA Electrical Contractor: [-E-Mail Address: Contractor Signature: Town of Vail Reg. No.: / /y9-E et G0 f: VA i . NCA Contact and Phone #'s: ?Q e. R,GI?c at-? 308-9377- COMPLETE SQ. FEET FOR NEW BUILDS and VALUATIONS FOR ALL OTHERS (Labor & Materials) II AMOUNT OF SQ FT IN STRUCTURE: (7,--- c? II ELECTRICAL VALUATION: $ /-/. 700 I Contact Eagle County Assessors Office at 970-328-8640 or visit www, ea4/e-county, com for Parcel # Parcel # c ( I ?l OC?C )C'J rx h ?? -2) L.,e () () L - Job Name: /? ?' L nn II Job Address: I_WN 0't (/N?/ ip/ eoOAAku,r,i J Oe-1/GlOR Il 75 S. Froiv?RSe- /?? Legal Description II Lot: Block: (I Filing: ?I Subdivision: y??_S Z 3g Owners Name: 74?wnr n? VAi ( I Address: 7?F?on??AaQ I Phone: 9.70 Engineer: Address: ?oQ i?c; AvQ? ?I Phone: ?? _. JC0 Detailed description of work: Zo Work Class: New( Addition ( ) Remodel (I,< Repair ( ) Temp Power ( ) Other ( ) Work Type: Interior (-?_ Exterior ( ) Both ( ) II Does an EHU exist at this location: Yes( ) No (V? Type of Bldg.: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial (?1 Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: 4-:1 I No. of Accommodation Units in this building: Is this permit for a hot tub: Yes ) No (?j Does a Fire Alarm Exist: Yes No( ) ?I Does a Fire Sprinkler SXstem Exist: Yes( ) No (v? uic „II 0., 5' 2vr /1??3 ***************,?********? *FOR OFFICE USE ONLY****,??€9s x****,?*,?**** ?e Other Fees: I Date Received: '°--°?°'*•tfi_ DRB Fees: Accepted By: Planner Sign-off: \\Vail\data\cdev\FORMS\PERMITS\ELECPERM.DOC 07/26/2002 EXTERIOR 1 INTERIOR •i . HOLY CROSS TRANSFORMER PANEL NEW 125A, 20BY/12OV, 30, 4W, 30 PA L SPACE PANELBOARD WITH 100/3 MAIN CIRCUIT BREAKER. CONNECT TO SERVICE n ENTRANCE CABLE WITH 4—#1/0 AL, #6 GRD. 100/3 INSTALL AT (E) PANEL LPP LOCATION. FEEDER TO BE LESS THAN 25' PER NEC. ■i m 3200/3 WITH 2X FRN -150 AND 1X FRN -175 FUSE WIRE GUTTER CU + GRD dw MAIN LEVEL 4 -250 KCMIL AL FLAG NOTES: ELECTRICAL ONE LINE DIAGRAM NO SCALE PANEL E1 208 Y/ 120 VOLT 3 PHASE 4 WIRE 100 AMPERE MAIN C.B. 225 AMPERE BUS LOCATION MAIN ELECTRICAL ROOM SUB TOTALS MOUNTING SURFACE A.I.C. 10,000 of 1 O NOTES: — EXISTING PANEL TO BE DEMOLISHED NOTES: UNE TOTALS 0 LOAD 0 CIRCUIT TYPE I CIRCUIT BREAKER BUS CIRCUIT BREAKER CIRCUIT TYPE LOAD LOAD MOTOR ADDER m LINE A LINE B _ LINE C REC uzES LOAD DESCRIPTION 0 TRa� �► BC 7w POLES REC uses LOAD DESCRIPTION LINE A LINE B LINE C Q 1 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR —z LINE A LINE B LINE C REC OPEN WORK SPACE 1 20 Ili TMP 100 z LINE A LINE B MAIN C.B. C REC urES 2 3 CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE 1 A a c Tray LOBBY REC./EXT. CONFERENCE ROOM NE REC. OFFICE #2 REC, CONTINUOUS FROM OUTLET TO OUTLET AND THAT SUCH CIRCUIT OR SYSTEMS LINE A LINE B LINE C Uz 1 1 — EM LIGHTING MAKE HIS WORK MEET EXISTING CONDITIONS. 4 5 3 3 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT 11MES APPROVED BY 20 15 CONFERENCE ROOM NE REC. OFFICE #2 REC. CIRC. PUMP #1 �■ 3 17, 2 3 FRONT EXT. BRACKET LTS. NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. OFFICE #3 REC. 6 7 -.. — 4 5 PRIOR TO ROUGH —IN. OPEN WORK SPACE SE REC. OFFICE #1 REC. 19. 20 1 MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND DISHWASHER 4 FRONT RECESSED EXT. LTS. ORDINANCES, 8 9 — ACTUALLY SUPPLIED. 6 7 SMALL CONFERENCE RM. REC 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED 8. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND 3 BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF �■ 100 FIRE ALARM 21. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT EAST EXTERIOR LTS. 10 11 EF -1 (NEW) SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 9. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR 8 SPEED EXH. FAN CSO /CEO OFFICE SE REC. 3 SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL EAST LUNCH RM. PLUGS 15 1200 REQUIRED. BACK ROOM 8 9 SCHEDULE OF DIRECTORIES TO OWNER FOR APPROVAL. ROOM NAMES AND 12 13 9 SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS, 10 OFFICE #10 EAST WALL REC. — FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF WEST LUNCH RM. REC. VIBRATING EQUIPMENT SHALL BE WITH SEAL 11TE FLEX AND APPROVED SPARE FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO RECEPTION AREA DUCTWORK OR MECHANICAL EQUIPMENT. AS REQUIRED TO MAINTAIN AND /OR RESTORE CONTINUITY OF SERVICE TO 14 15 EXISTING CIRCUITS. 10 11 — WITHIN WIRE GUTTER AND PROVIDE NEW CONNECTOR(S) OFFICE #2— CONTT. INSPECTOR �� FOR PROPER CONNECTION OF ALL CONDUCTORS. — a J • ! PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. OFFICE #1 ( INSP. OFFICE WEST REC. 3 500 12 16 17 EAST LOBB 12 13 INSP. OFFICE NE REC. 14 UNIT HEATER ON DOCK 1 20 SPARE 500 20 1 18 19 SPARE LOBBY ENTR., OFFICE LTS. 14 SYNTH NORTH + SOUTH REC. REST ROOM RECEPT OFFICE #8 NORTH WALL REC. 20 _ 500 20 21 17 FRONT BOX LTS. BUILDING LOBBY AREA RECEPTION AREA E +SW REC. .� 17 _ , REAR AREA D ESK REC. OFFICE #7 EAST WALL REC. 220V OUTLET DOCK - 2 22 23 18 19 500 EAST BACK BOX LTS. OFFICE #6 EAST WALL REC. CIRC. PUMP #2 (E) 1 3 18 19 OFFICE #5 EAST WALL REC. : _.... 24 25 20 20 21 :• • . 500 OFFICE #4 EAST WALL REC. SPARE 20 OFFICE #4 WEST WALL REC, LIGHTS AT PULL BOX LTG. 26 27 COPIER 1 20 FOY I LIGHTS IIIIIII� MICROWAVE 500 _ _ 15 OFFICE #1 SOUTH WALL REC. •• 22 28 29 SPARE OFFICE #3 WALL REC. 1 20 SPEED EXH. F AN. _(E) ...._ SPARE FRON WO R K ROOM L T S. 30 31 24 OFFICE #1 WALL REC. DECK LIGH 1 rllG 26 27 500 • KITCHEN SMALL APPLIANCE 32 33 220V D(JCK OUTLET (E) CEO OFFICE EAST WALL REC. 20001 o i`�u, � I,�I R OOM ' 28 29 500 - WEATHER STATION X— FORMER — 34 35 2 — _., . , ... _ .. OFFICE #3 • . 30 31 SPARE 36 ..... ...... .. . . w ' r j 208 * PHASE 0 0 0 WIRE SUB TOTALS 1 0 of 1 O NOTES: — EXISTING PANEL TO BE DEMOLISHED NOTES: UNE TOTALS 0 0 0 y I LCL ADDER 0 0 0 LOAD _ {STING PANEL MOTOR ADDER ir" 0 CIRCUIT BREAKER BUS CIRCUIT BREAKER TOTAL VA /I 0 0 0 � w a' LINE AMPS 0 1 0 1 0 LOAD DESCRIPTION REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL TOTAL KVA LOAD LOAD DESCRIPTION 0 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR ..... ...... .. . . w ' r j 208 * PHASE w AM L. AMPER PHASE L OCATION HALLWAY WIRE 60 AMPERE MAIN L.O. MOUNTING 0 • III >1 ELECTRICAL ROOM 0 NOTES: — EXISTING PANEL TO BE DEMOLISHED LINE TOTALS LCL ADDER MOTOR ADDER TOTAL VA /I LINE AMPS TOTAL KVA LOAD 0 MOUNTING SURFACE A.I.C. 10, 000 1 r y I n a a . CIRCUIT BREAKER CIRCUIT TYPE a! LOAD I' • r CIRCUIT TYPE ir" 0 CIRCUIT BREAKER BUS CIRCUIT BREAKER CIRCUIT TYPE LOAD DESCRIPTION LOAD DESCRIPTION LOAD � w a' LINE AMPS --- 0 0 LOAD DESCRIPTION REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL LOAD DESCRIPTION LOAD DESCRIPTION --8 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR —z LINE A LINE B LINE C REC LOAD DESCRIPTION LOAD DESCRIPTION CONSTRUCTION, CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, Ili TMP v z LINE A LINE B LINE C REC urES LINE B LINE C # CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE 1 A a c Tray LOBBY REC./EXT. uTES OFFICE #2 REC, CONTINUOUS FROM OUTLET TO OUTLET AND THAT SUCH CIRCUIT OR SYSTEMS LINE A LINE B LINE C Uz 1 1 VAIL POLICE DEPT. OUTLET EM LIGHTING MAKE HIS WORK MEET EXISTING CONDITIONS. AHU -1 (NEW) : , -._ H +V UNIT 3 3 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT 11MES APPROVED BY 20 15 OWNER — IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OFFICE #2 REC. CIRC. PUMP #1 �■ OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 17, 2 3 FRONT EXT. BRACKET LTS. NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. OFFICE #3 REC. 3 — #10, #10 GRD -.. — 4 5 PRIOR TO ROUGH —IN. SATISFACTION OF THE OWNER. OFFICE #1 REC. 19. ■ 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND 4 FRONT RECESSED EXT. LTS. ORDINANCES, OFFICE #4 REC. PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT — ACTUALLY SUPPLIED. 6 7 30 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED 8. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND 3 BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF �■ 100 ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY 21. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT EAST EXTERIOR LTS. 7 OFFICE #4 REC. EF -1 (NEW) SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 9. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR 8 SPEED EXH. FAN CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, 3 SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL EAST LUNCH RM. PLUGS 15 1200 REQUIRED. CIRC. PUMP #2 8 9 SCHEDULE OF DIRECTORIES TO OWNER FOR APPROVAL. ROOM NAMES AND 23. 8 9 SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS, 10 11 — FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF WEST LUNCH RM. REC. VIBRATING EQUIPMENT SHALL BE WITH SEAL 11TE FLEX AND APPROVED SPARE FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS DUCTWORK OR MECHANICAL EQUIPMENT. AS REQUIRED TO MAINTAIN AND /OR RESTORE CONTINUITY OF SERVICE TO FRONT I OBBY LTS. EXISTING CIRCUITS. 10 11 — WITHIN WIRE GUTTER AND PROVIDE NEW CONNECTOR(S) 12 �� FOR PROPER CONNECTION OF ALL CONDUCTORS. — a J • ! PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. OFFICE #1 ( AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). 3 500 12 — 500 EAST LOBB 12 13 3 14 UNIT HEATER ON DOCK 1 20 500 20 1 14 15 SPARE LOBBY ENTR., OFFICE LTS. 14 15 REST ROOM RECEPT 1 20 _ 500 16 17 FRONT BOX LTS. BUILDING LOBBY AREA — .� 17 _ , REAR AREA D ESK REC. 220V OUTLET DOCK - 2 18 19 500 EAST BACK BOX LTS. OFFICE #1 CIRC. PUMP #2 (E) 1 3 18 19 C OUNTER OUTLETS : _.... — 20 20 21 :• • . 500 SPARE 20 21 LIGHTS AT PULL BOX LTG. COPIER 1 20 FOY I LIGHTS IIIIIII� 500 _ _ 15 •• 22 23 SPARE R ESERVATI 1 20 SPEED EXH. F AN. _(E) ...._ 3 FRON WO R K ROOM L T S. _ 24 DECK LIGH 1 rllG 26 27 500 • F RONT WORKROOM 220V D(JCK OUTLET (E) 20001 o i`�u, � I,�I R OOM ' 28 29 500 - — 15 TELEPH 2 — _., . , ... _ .. ., • . 30 31 - ! WORK 32 33 ROOM C• 34 35 BR EAKER 36 37 3$ • • ♦ s s 4 -4/0 AL + GRD Q CONTRACTOR SHALL REPLACE ALL FUSES WITH THREE FRN -175 FUSES. LOAD SUMMARY; IN ACCORDANCE WITH NEC 220 -35 FOR EXISTING INSTALLATIONS, THE MAXIMUM DEMAND OBTAINED FOR THE BUILDING WAS 60 AMPS. TAKING THE EXISTING LOAD AT 125% AND ADDING THE NEW LOAD, THE CALCULATED LOAD EQUATES TO 120 AMPS WHICH IS BELOW THE 200 AMP SERVICE SIZE. PANEL LPP 208 Y/ 120 VOLT 3 PHASE 4 WIRE 60 AMPERE MAIN L.O. 125 AMPERE BUS LOCATION MAIN ELECTRICAL ROOM 0 NOTES: — EXISTING PANEL TO BE DEMOLISHED LINE TOTALS LCL ADDER MOTOR ADDER TOTAL VA /I LINE AMPS TOTAL KVA LOAD 0 MOUNTING SURFACE A.I.C. 10, 000 0 0 0 0 CIRCUIT BREAKER CIRCUIT TYPE a! LOAD LOAD CIRCUIT TYPE 0 0 CIRCUIT BREAKER BUS CIRCUIT BREAKER CIRCUIT TYPE LOAD DESCRIPTION 0 LOAD � w a' LINE AMPS --- 0 0 LOAD DESCRIPTION REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL LOAD DESCRIPTION LOAD DESCRIPTION --8 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR —z LINE A LINE B LINE C REC LOAD DESCRIPTION LOAD DESCRIPTION CONSTRUCTION, CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, Ili TMP v z LINE A LINE B LINE C REC urES LINE B LINE C # CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE 1 A a c Tray REC uTES OFFICE #2 REC, CONTINUOUS FROM OUTLET TO OUTLET AND THAT SUCH CIRCUIT OR SYSTEMS LINE A LINE B LINE C Uz 1 1 INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO EM LIGHTING MAKE HIS WORK MEET EXISTING CONDITIONS. AHU -1 (NEW) : , -._ H +V UNIT 3 3 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT 11MES APPROVED BY 20 15 OWNER — IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OFFICE #2 REC. CIRC. PUMP #1 11.76 OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 17, 2 3 2100 NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. OFFICE #3 REC. 3 — #10, #10 GRD -.. — 4 5 PRIOR TO ROUGH —IN. SATISFACTION OF THE OWNER. OFFICE #1 REC. 19. — 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND 4 r 5 ORDINANCES, OFFICE #4 REC. PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT — ACTUALLY SUPPLIED. 6 7 30 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED 8. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND 3 BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF — 100 ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY 21. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT 6 7 OFFICE #4 REC. EF -1 (NEW) SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 9. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR 8 SPEED EXH. FAN CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, 3 SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL ETC. SHALL BE CONNECTED AND OPERABLE. 15 1200 REQUIRED. CIRC. PUMP #2 8 9 SCHEDULE OF DIRECTORIES TO OWNER FOR APPROVAL. ROOM NAMES AND 23. 8 9 SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS, 10 11 — FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF 115---o VIBRATING EQUIPMENT SHALL BE WITH SEAL 11TE FLEX AND APPROVED SPARE FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS DUCTWORK OR MECHANICAL EQUIPMENT. AS REQUIRED TO MAINTAIN AND /OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS. 10 11 — WITHIN WIRE GUTTER AND PROVIDE NEW CONNECTOR(S) 12 13 FOR PROPER CONNECTION OF ALL CONDUCTORS. — PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. OFFICE #1 ( AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). 3 500 12 — 500 12 13 3 14 UNIT HEATER ON DOCK 1 20 500 20 1 14 15 SPARE 500 14 15 EF -1, 2, 3, 5 1 20 _ 500 16 17 BUILDING LOBBY AREA — 16 17 _ 220V OUTLET DOCK - 2 18 19 500 OFFICE #1 CIRC. PUMP #2 (E) 3 18 19 : _.... — 20 20 21 500 SPARE 20 21 COPIER 1 20 23 500 _ _ 15 22 23 SPARE 24 1 20 SPEED EXH. F AN. _(E) ...._ 3 _ 24 PANEL E2 208 Y/ 120 VOLT 3 0 1 0 1 0 1 1 SUB TOTALS SUB TOTALS 0 1 0 0 0 NOTES: — EXISTING PANEL TO BE DEMOLISHED LINE TOTALS LCL ADDER MOTOR ADDER TOTAL VA /I LINE AMPS TOTAL KVA LOAD 0 0 0 0 0 0 0 CIRCUIT BREAKER CIRCUIT TYPE 0 14. LOAD 0 0 0 ADDENDUM SHALL BE BINDING, NO BIDDER SHALL RELY UPON 0 0 0 LOAD DESCRIPTION 0 PANEL E2 208 Y/ 120 VOLT 3 PHASE 4 WIRE 60 AMPERE MAIN C.B. 125 AMPERE SUS LOCATION HALLWAY SUB TOTALS MOUNTING FLUSH A.I.C. 10, 000 0 0 NOTES: — NEW PANEL — CONTRACTOR TO RECONNECT EXISTING LOADS TO NEW PANEL — ALL DISCONNECTS FOR NEW EQUIPMENT BY DIVSION 16. NOTES: m LOAD CIRCUIT TYPE 0 0 CIRCUIT BREAKER BUS CIRCUIT BREAKER CIRCUIT TYPE 0 14. LOAD 9876 EXISTING BUILDINGS ARE TO BE NOTED "FOR GUIDANCE ONLY ". THE ADDENDUM SHALL BE BINDING, NO BIDDER SHALL RELY UPON 71.4 ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS TOTAL VA /I LOAD DESCRIPTION 0 0 REMOVAL AND /OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, LINE AMPS 0 0 0 LOAD DESCRIPTION REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL TOTAL KVA LOAD LOAD DESCRIPTION --8 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR —z LINE A LINE B LINE C REC cr>ES LOAD DESCRIPTION CONSTRUCTION, CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, Ili TMP A a C TMP ►Est REC LIES LINE C TO OWNER APPROVAL. LINE A LINE B LINE C # CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE 1 WHERE THE REUSE OF EXISTING CONDUITS, WIRES, DEVICES, ETC. CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE FULL INTENT AND IS PERMISSIBLE, MAKE CERTAIN THAT THE WIRING FOR SAME IS SCOPE OF THE WORKING DRAWINGS AND SPECIFICATIONS. OFFICE #2 REC, CONTINUOUS FROM OUTLET TO OUTLET AND THAT SUCH CIRCUIT OR SYSTEMS 1 20 SHALL PASS THROUGH NO OUTLET OR JUNCTION BOXES WHICH MAY BE 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS 20 1 INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO EM LIGHTING MAKE HIS WORK MEET EXISTING CONDITIONS. AHU -1 (NEW) : , -._ INDICATED FOR REUSE SHALL BECOME THE PROPERTY OF THIS CONTRACTOR 2 3 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT 11MES APPROVED BY 20 BREAKERS, FIRE ALARM EQUIPMENT, WIRE, ETC. SHALL BECOME THE OWNER — IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OFFICE #2 REC. OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE 11.76 OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 17, PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND 2100 NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. OFFICE #3 REC. 3 — #10, #10 GRD -.. 18. 4 5 PRIOR TO ROUGH —IN. SATISFACTION OF THE OWNER. OFFICE #1 REC. 19. _ 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ORDINANCES, OFFICE #4 REC. PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT — ACTUALLY SUPPLIED. 6 7 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED 8. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND OFFICE #1 REC. BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF 100 ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY 21. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT REMEDIED WITHOUT COST TO THE OWNER. OFFICE #4 REC. EF -1 (NEW) SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 9. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR 8 9 CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, 22. SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL ETC. SHALL BE CONNECTED AND OPERABLE. OFFICE #3 REC. 1200 REQUIRED. 10. PANEL DIRECTORIES SHALL BE REMOVABLE. SUBMIT PROPOSED 8 9 SCHEDULE OF DIRECTORIES TO OWNER FOR APPROVAL. ROOM NAMES AND 23. NON — METALLIC AND FLEXIBLE METAL CONDUITS SHALL HAVE A CODE — LIGHTING SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS, 10 11 24. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF VIBRATING EQUIPMENT SHALL BE WITH SEAL 11TE FLEX AND APPROVED SPARE FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS DUCTWORK OR MECHANICAL EQUIPMENT. AS REQUIRED TO MAINTAIN AND /OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS. HEATING TRANSFORMER ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXISTING SPLICE — WITHIN WIRE GUTTER AND PROVIDE NEW CONNECTOR(S) 12 13 FOR PROPER CONNECTION OF ALL CONDUCTORS. REMAINING TO BE RECONNECTED TO NEW OR EXISTING SWITCHBOARDS/ PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. OFFICE #1 ( AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). 500 12 13 500 SPARE CIRC. PUMP #1 (E) 3 14 !• ! M y toy, A I t off , 1. EXAMINATION OF BIDDING DOCUMENTS. 0 0 0 4 SUB TOTALS 1 0 1 0 0 NOTES: — NEW PANEL — CONTRACTOR TO RECONNECT EXISTING LOADS TO NEW PANEL — ALL DISCONNECTS FOR NEW EQUIPMENT BY DIVSION 16. NOTES: LINE TOTALS 0 0 0 0 PROVIDED, LCL ADDER 0 0 0 14. — EXISTING PANEL MOTOR ADDER 9876 EXISTING BUILDINGS ARE TO BE NOTED "FOR GUIDANCE ONLY ". THE ADDENDUM SHALL BE BINDING, NO BIDDER SHALL RELY UPON 71.4 ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS TOTAL VA /I 0 0 0 REMOVAL AND /OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, LINE AMPS 0 0 0 REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL TOTAL KVA LOAD LOAD DESCRIPTION 0 OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR !• ! M y toy, A I t off , 1. EXAMINATION OF BIDDING DOCUMENTS. 13. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED PHASE 4 CONDUIT, WIRE, CABLE, J— BOXES, RECEPTACLES, SWITCHES, LIGHTS, A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY, LOCATION MAIN ELECTRICAL ROOM _.. FIRE ALARM DEVICES, ETC, COMPLETE WITH ASSOCIATED CIRCUITING TO AND NOT LATER THAN SEVEN DAYS PRIOR TO THE DATE OF RECEIPT OF NOTES: — NEW PANEL — CONTRACTOR TO RECONNECT EXISTING LOADS TO NEW PANEL — ALL DISCONNECTS FOR NEW EQUIPMENT BY DIVSION 16. SOURCE, WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET BIDS, SHALL MAKE WRITTEN REQUEST TO THE ENGINEER FOR 9 876 SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES INTERPRETATION OR CORRECTION OF ANY DISCREPANCIES, AMBIGUITIES, 0 PROVIDED, INCONSISTENCIES, OR ERRORS THEREIN WHICH HE MAY DISCOVER. THE ENGINEER WILL BE ISSUE ANY INTERPRETATION OR CORRECTION AS AN 14. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR ADDENDUM. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY 9876 EXISTING BUILDINGS ARE TO BE NOTED "FOR GUIDANCE ONLY ". THE ADDENDUM SHALL BE BINDING, NO BIDDER SHALL RELY UPON 71.4 ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS INTERPRETATIONS OR CORRECTIONS GIVEN BY ANY OTHER METHOD. IF CIRCUIT BREAKER PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE FOR DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS ARE NOT REMOVAL AND /OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, CONTRACTOR SHALL FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS INCLUDE IN HIS BID, LABOR MATERIALS AND METHODS OF CONSTRUCTION REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE LOAD DESCRIPTION SYSTEM TO ALL OTHER WORK AS REQUIRED. OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR � DUE TO HIS FAILURE TO MAKE THE WRITTEN REQUESTS AS DESCRIBED 15. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING ABOVE, LOAD DESCRIPTION CONSTRUCTION, CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, Ili CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF B. FAILURE TO REQUEST CLARIFICATION DURING THE BID PERIOD OF —Z SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE LINE C TO OWNER APPROVAL. CONTRACTOR OF THEIR RESPONSIBILITIES. THE SIGNING OF THE CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE 16. WHERE THE REUSE OF EXISTING CONDUITS, WIRES, DEVICES, ETC. CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE FULL INTENT AND IS PERMISSIBLE, MAKE CERTAIN THAT THE WIRING FOR SAME IS SCOPE OF THE WORKING DRAWINGS AND SPECIFICATIONS. . CONTINUOUS FROM OUTLET TO OUTLET AND THAT SUCH CIRCUIT OR SYSTEMS LINE A LINE B SHALL PASS THROUGH NO OUTLET OR JUNCTION BOXES WHICH MAY BE 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS 1 RENDERED INACCESSIBLE BY THE STRUCTURAL CHANGES TO BE MADE TO THE INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO BUILDING. EXISTING CONDUITS, WIRE, DEVICES, ETC, WHICH ARE NOT MAKE HIS WORK MEET EXISTING CONDITIONS. AHU -1 (NEW) : , -._ INDICATED FOR REUSE SHALL BECOME THE PROPERTY OF THIS CONTRACTOR HOWEVER LIGHTING FIXTURES, PANEL FUSED SWITCHES, CIRCUIT 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT 11MES APPROVED BY 20 BREAKERS, FIRE ALARM EQUIPMENT, WIRE, ETC. SHALL BECOME THE OWNER — IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL PROPERTY OF THE OWNER. OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE 11.76 OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 17, PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND 2100 NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. 4. REVIEW MECHANICAL DRAWINGS PRIOR TO BID. 3 — #10, #10 GRD -.. 18. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS 5, WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE PRIOR TO ROUGH —IN. SATISFACTION OF THE OWNER. P -2 (N 19. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ORDINANCES, PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT — ACTUALLY SUPPLIED. 7. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 20. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED 8. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND , CUH -1 (NEW) BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF 100 ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY 21. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT REMEDIED WITHOUT COST TO THE OWNER. BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS EF -1 (NEW) SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 9. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, 22. SEE DIVISION 15 DRAWINGS FOR LOCATION OF MECHANICAL ETC. SHALL BE CONNECTED AND OPERABLE. EQUIPMENT. PROVIDE SERVICE TO, AND CONNECT EQUIPMENT AS 1200 REQUIRED. 10. PANEL DIRECTORIES SHALL BE REMOVABLE. SUBMIT PROPOSED 8 9 SCHEDULE OF DIRECTORIES TO OWNER FOR APPROVAL. ROOM NAMES AND 23. NON — METALLIC AND FLEXIBLE METAL CONDUITS SHALL HAVE A CODE — NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS, REQUIRED. 11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO 24. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF VIBRATING EQUIPMENT SHALL BE WITH SEAL 11TE FLEX AND APPROVED DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS DUCTWORK OR MECHANICAL EQUIPMENT. AS REQUIRED TO MAINTAIN AND /OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS. 25, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXISTING SPLICE — WITHIN WIRE GUTTER AND PROVIDE NEW CONNECTOR(S) 12. FIELD VERIFY EXISTING EQUIPMENT OR CIRCUITS THAT ARE FOR PROPER CONNECTION OF ALL CONDUCTORS. REMAINING TO BE RECONNECTED TO NEW OR EXISTING SWITCHBOARDS/ PANELBOARDS. PROVIDE SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. OFFICE #1 ( AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). 500 PANEL LPP ~ 208 Y/ 120 VOLT "S PHASE 4 WIRE 100 AMPERE MAIN C.B. 125 AMPERE BUS LOCATION MAIN ELECTRICAL ROOM _.. 1 260 iz NOTES: — NEW PANEL — CONTRACTOR TO RECONNECT EXISTING LOADS TO NEW PANEL — ALL DISCONNECTS FOR NEW EQUIPMENT BY DIVSION 16. MOUNTING SURFACE A.I.C. 10,000 9 876 8300 0 0 0 w LOAD 9876 CIRCUIT TYPE 71.4 CIRCUIT BREAKER BUS CIRCUIT BREAKER CIRCUIT TYPE LOAD LOAD DESCRIPTION � r 0Z - 6i LOAD DESCRIPTION Ili _ G —Z LINE A A LINE B LINE C REC True a c TPoa REC uTES . LINE A LINE B LINE Uz 1 2100 AHU -1 (NEW) : , -._ .. ...._3. 20 1 P -1 (NE 11.76 2 3 2100 3 — #10, #10 GRD -.. P -2 (N .1176 4 5 _ 2100 — 35 , CUH -1 (NEW) 100 6 7 2100 EF -1 (NEW) 3� COPIER (E) 1200 8 9 2100_ #10 GRD - BUILDING LOBBY (E) 500 10 11 2100 — 35 OFFICE #1 ( 500 12 13 500 CIRC. PUMP #1 (E) 3 EF- 1,2, (E) 500 14 15 500 — _ .. .. DOCK ,UNIT„ HEATER (E), _ _ _ 500 16 17 500 — 15 _ SPARE - 18 19 500 CIRC. PUMP #2 (E) 3 : _.... 20 21 500 22 23 500 _ _ 15 _ 24 25 500 SPEED EXH. F AN. _(E) ...._ 3 _ 26 27 500 220V D(JCK OUTLET (E) 20001 28 29 500 - — 15 2 — _., . , ... _ .. ., 2000 30 31 - 32 33 34 35 36 37 3$ 1 i `Patdck A. Bums LIB. 370 �i� U qy r'd !'t "I ml 1 � ml 11 5700 5700 5700 SUB TOTALS 1 _ 1 2876 1 4176 1 260 iz NOTES: — NEW PANEL — CONTRACTOR TO RECONNECT EXISTING LOADS TO NEW PANEL — ALL DISCONNECTS FOR NEW EQUIPMENT BY DIVSION 16. LINE TOTALS LCL ADDER MOTOR ADDER TOTAL VA /I LINE AMPS TOTAL KVA LOAD 8576 9 876 8300 0 0 0 8576 9876 8300 71.4 82.3 69.1 26.7 1 i `Patdck A. Bums LIB. 370 �i� U qy r'd !'t "I ml 1 � ml 11 11-1 iz Ljj iz Ljj ►• •r � • sf � r 0Z - 6i Ili M � E E03 -0012: Entries for Item: 190 - ELEC -Final 09:22 02/19/2013 Action Comments By Date Unique_ Key APPR eg 08/07/2003 A000065 307 Total Rows: 1 Page 1