Loading...
HomeMy WebLinkAboutB18-0434_Approved Documents_1540246167.pdf 75 South Frontage Road Construction 0West, TOWN OF VAIL B18-0434 TOWN Vail,CO 81657 Issued: 10/22/2018 TOWN Or VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 701 W LIONSHEAD CIR(210106333005) (210106333005 ) Unit#: Parcel Number: 210106333005 LegalDescription: DESC: COMMERCIAL UNIT Subdivision:LION(THE)Unit:C Contacts Contact Type:Applicant Full Name:Warren Krok Address: 40690 Hwy 6 D Avon,CO 81620 Phone: 9708451001 Contact Type:Property Owner Full Name:LIONVAILLLC Address: Phone: None Contractor Contractor Type:General Company: Nedbo Constructionlnc State License#: Phone: 970-845-1001 Projectinformation Project Name:The Lion Venture Sports2018 Tenant finish project-New Venture Sports shop will be located i the commercial space inside the Lion.New Project Description: workincludes constructing new partition walls with dropped ceiling and newfloor finishes.Project will also include new mechanical and electrical along with new built in seating and ski work benches Fees Paid Account#:001-0000.31111.00-Building Permit Fee Fee Amount: $993.75 Account#:001-0000.31123.00 Building Plan Review Fee Fee Amount: $645.94 Account#: 110-0000.31060.00Construction Use Tax Fee Fee Amount: $1,800.00 Account#:001-0000.31111.00-MechanicalPermit Fee Fee Amount: $300.00 Account#:001-0000.31123.00 MechanicalPlan Review Fee Fee Amount: $75.00 Account#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00 Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) Fee Amount: $5.00 Total Paid: $3,824.69 Conditions CONDITIONS UNDER WHICHPERMITS BECOME VOID: If construction is not begun within 6 months from the date permitwas issued. If more than 5 months elapses betweeninspections. If incorrectinformationis given on the application at the time the permitwas issued. Christopher Jarecki-Town of Vail Building Official NOTICE:By issuance of this Permitthe applicant agrees to complywith all Titles of the Town of Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shallforfeit all applicablefees. °I1111 PERMIT FEE RECEIPT TOWN OF VAIL Case # B18-0434 Date Printed: 10/22/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0434 Status: Approved Permit Number: Date Started: 09/25/2018 Permit Type: Construction Subc ases Commercial Lot Number: 1 Property: 701 W LIONSHEAD CIR(210106333005) (210106333005) Contacts Contact Type: Applicant Company Name: Nedbo Construction Full Name: Warren Krok Address: 40690 Hwy 6 D Avon,CO 81620 Email: warren@nedbo.com Contact Type: Property Owner Full Name: LION VAIL LLC Address: Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $1,293.75 Construction Tax 110-0000.31060.00 $1,800.00 Plan Review 001-0000.31123.00 $75.00 W ill Call Fee 001-0000.31128.00 $10.00 Payment Information Date Paid Payment Type Amount, W ill Call Fee 10/22/2018 Credit Card $10.00 Paid By: -Notes:visa-roland kjesbo Construction Tax 10/22/2018 Credit Card $1,800.00 Paid By: -Notes:visa-roland kjesbo Permit Fee 10/22/2018 Credit Card $1,293.75 Paid By: -Notes:visa-roland kjesbo Plan Review 10/22/2018 Credit Card $75.00 Paid By: -Notes:visa-roland kjesbo FEE TOTAL $3,178.75 AMOUNT PAID $3,178.75 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 10/22/2018 -4:03:25 PM-Generated by:cgodfrey 1/1 ifift COMcheck Software Version 4.0.8.1 A4 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Venture Sports Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 701 West Lionshead Circle Venture Sports Andrew Wilder Vail, CO 81657 701 West Lionshead Circle Wilder Engineering LLC Vail, CO 81657 1170 Blue Sage Drive Steamboat Springs,CO 80487 970-819-7848 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Sales Area(Retail:Sales Area) 679 1.59 1080 2-Equipment Storage(Common Space Types:Storage>=50-<=1000 sq.ft.) 220 0.63 139 Total Allowed Watts= 1218 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales Area( Retail:Sales Area 679 sq.ft.) LED 2: FB:Downlight:LED Other Fixture Unit 36W: 1 10 34 340 LED 3: FC:Wallwash: LED Other Fixture Unit 36W: 1 6 30 180 Equipment Storage(Common Space Types:Storag e>=50-<=1000 sq.ft.220 sq.ft.) LED 1: FA:Recessed LED:LED Linear 22W: 1 4 21 84 Total Proposed Watts= 604 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IE CC requiremen .in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection C -cklist. Andrew Wilder- PE 9-18-18 Name -Title Signatur- Date Project Title: Venture Sports Report date: 09/17/18 Data filename: C:\_Wilder Engineering\_Projects\Rader Engineering\2018058-Venture Page 1 of 5 Sports\Calculations\Comcheck.cck COMcheck Software Version 4.0.8.1 IP11.6 Inspection Checklist Energy Code: 2015 I E CC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions"column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications,and/or EComplies [PR4]1 calculations provide all information Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Venture Sports Report date: 09/17/18 Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 2 of 5 Sports\Calculations\Comcheck.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 1 C405.2.1 Lighting controls installed to uniformly ❑Complies [E L15p reduce the lighting load by at least ❑Does Not 50%. [Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies [E L1811 required spaces. ❑Does Not ['Not Observable ❑Not Applicable C405.2.1, 'Independent lighting controls installed ❑Complies C405. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and [E L23 visible to occupants. ['Not Observable ❑Not Applicable C405.2.2. ,Automatic controls to shut off all '❑Complies 1 :building lighting installed in all ❑Does Not [E L22F ;buildings. ❑Not Observable ❑Not Applicable 3 'Daylight zones provided with ❑Complies [E individual controls that control the ❑Does Not lights independent of general area lighting. ENot Observable ❑Not Applicable C405.2.3, Primarysidelighted areas are ❑Complies C405.2.3. equipped with required lighting ❑Does Not 1, controls. C405.2.3. ❑Not Observable 2 ❑Not Applicable [E L20p C405.2.3, I Enclosed spaces with daylight area ;❑Complies C405.2.3. :under skylights and rooftop monitors ❑Does Not 1, :are equipped with required lighting C405.2.3. ;controls. ['Not Observable 3 j ❑Not Applicable [EL21)1 I C405.2.4 Separate lighting control devices for ❑Complies [E L411 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ❑Complies [E L8]1 allowed for special functions per the ❑Does Not ;approved lighting plans and is :automatically controlled and ['Not Observable separated from general lighting. ❑Not Applicable C405.3 ;Exit signs do not exceed 5 watts per ❑Complies [EL6p :face. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Venture Sports Report date: 09/17/18 Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 3 of 5 Sports\Calculations\Comcheck.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID 1 C303.3, ,Furnished O&M instructions for ❑Complies C408.2.5. :systems and equipment to the ❑Does Not 2 building owner or designated [F117]3 representative. [Not Observable j ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 i lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts [Not Observable are less than or equal to allowed Observable,__, Applicable watts. C408.2.5. :Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ❑Does Not [F116]3 of system acceptance. [Not Observable ❑Not Applicable C408.3 ;Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration,adjustment, ❑Does Not :programming,and operation. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Venture Sports Report date: 09/17/18 Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 4 of 5 Sports\Calculations\Comcheck.cck Project Title: Venture Sports Report date: 09/17/18 Data filename: C:\_Wilder Engineering\_Projects\Rader Engineering\2018058-Venture Page 5 of 5 Sports\Calculations\Comcheck.cck