HomeMy WebLinkAboutB18-0434_Approved Documents_1540246167.pdf 75 South Frontage Road Construction
0West, TOWN OF VAIL B18-0434
TOWN
Vail,CO 81657 Issued: 10/22/2018
TOWN Or VAIL Office:970.479.2139
Inspections:
inspections@vailgov.com
Property Information
Address: 701 W LIONSHEAD CIR(210106333005) (210106333005 )
Unit#:
Parcel Number: 210106333005
LegalDescription: DESC: COMMERCIAL UNIT Subdivision:LION(THE)Unit:C
Contacts
Contact Type:Applicant
Full Name:Warren Krok
Address: 40690 Hwy 6 D Avon,CO 81620 Phone: 9708451001
Contact Type:Property Owner
Full Name:LIONVAILLLC
Address: Phone: None
Contractor
Contractor Type:General
Company: Nedbo Constructionlnc
State License#: Phone: 970-845-1001
Projectinformation
Project Name:The Lion Venture Sports2018
Tenant finish project-New Venture Sports shop will be located i the commercial space inside the Lion.New
Project Description: workincludes constructing new partition walls with dropped ceiling and newfloor finishes.Project will also
include new mechanical and electrical along with new built in seating and ski work benches
Fees Paid
Account#:001-0000.31111.00-Building Permit Fee Fee Amount: $993.75
Account#:001-0000.31123.00 Building Plan Review Fee Fee Amount: $645.94
Account#: 110-0000.31060.00Construction Use Tax Fee Fee Amount: $1,800.00
Account#:001-0000.31111.00-MechanicalPermit Fee Fee Amount: $300.00
Account#:001-0000.31123.00 MechanicalPlan Review Fee Fee Amount: $75.00
Account#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00
Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) Fee Amount: $5.00
Total Paid: $3,824.69
Conditions
CONDITIONS UNDER WHICHPERMITS BECOME VOID:
If construction is not begun within 6 months from the date permitwas issued.
If more than 5 months elapses betweeninspections.
If incorrectinformationis given on the application at the time the permitwas issued.
Christopher Jarecki-Town of Vail Building Official
NOTICE:By issuance of this Permitthe applicant agrees to complywith all Titles of the Town of Vail Code and all applicable State and Federal
law.Failure to do so will void this Permit and the applicant shallforfeit all applicablefees.
°I1111
PERMIT FEE RECEIPT
TOWN OF VAIL Case # B18-0434
Date Printed: 10/22/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0434 Status: Approved
Permit Number: Date Started: 09/25/2018
Permit Type: Construction Subc ases Commercial
Lot Number: 1
Property: 701 W LIONSHEAD CIR(210106333005) (210106333005)
Contacts
Contact Type: Applicant
Company Name: Nedbo Construction
Full Name: Warren Krok
Address: 40690 Hwy 6 D Avon,CO 81620
Email: warren@nedbo.com
Contact Type: Property Owner
Full Name: LION VAIL LLC
Address:
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $1,293.75
Construction Tax 110-0000.31060.00 $1,800.00
Plan Review 001-0000.31123.00 $75.00
W ill Call Fee 001-0000.31128.00 $10.00
Payment Information Date Paid Payment Type Amount,
W ill Call Fee 10/22/2018 Credit Card $10.00
Paid By: -Notes:visa-roland kjesbo
Construction Tax 10/22/2018 Credit Card $1,800.00
Paid By: -Notes:visa-roland kjesbo
Permit Fee 10/22/2018 Credit Card $1,293.75
Paid By: -Notes:visa-roland kjesbo
Plan Review 10/22/2018 Credit Card $75.00
Paid By: -Notes:visa-roland kjesbo
FEE TOTAL $3,178.75
AMOUNT PAID $3,178.75
BALANCE DUE $0.00
75 South Frontage Road West,Vail,Colorado 81657 10/22/2018 -4:03:25 PM-Generated by:cgodfrey
1/1
ifift COMcheck Software Version 4.0.8.1
A4 Interior Lighting Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: Venture Sports
Project Type: Alteration
Construction Site: Owner/Agent: Designer/Contractor:
701 West Lionshead Circle Venture Sports Andrew Wilder
Vail, CO 81657 701 West Lionshead Circle Wilder Engineering LLC
Vail, CO 81657 1170 Blue Sage Drive
Steamboat Springs,CO 80487
970-819-7848
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B X C)
1-Sales Area(Retail:Sales Area) 679 1.59 1080
2-Equipment Storage(Common Space Types:Storage>=50-<=1000 sq.ft.) 220 0.63 139
Total Allowed Watts= 1218
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales Area( Retail:Sales Area 679 sq.ft.)
LED 2: FB:Downlight:LED Other Fixture Unit 36W: 1 10 34 340
LED 3: FC:Wallwash: LED Other Fixture Unit 36W: 1 6 30 180
Equipment Storage(Common Space Types:Storag e>=50-<=1000 sq.ft.220 sq.ft.)
LED 1: FA:Recessed LED:LED Linear 22W: 1 4 21 84
Total Proposed Watts= 604
Interior Lighting PASSES
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting
systems have been designed to meet the 2015 IE CC requiremen .in COMcheck Version 4.0.8.1 and to comply with any
applicable mandatory requirements listed in the Inspection C -cklist.
Andrew Wilder- PE 9-18-18
Name -Title Signatur- Date
Project Title: Venture Sports Report date: 09/17/18
Data filename: C:\_Wilder Engineering\_Projects\Rader Engineering\2018058-Venture Page 1 of 5
Sports\Calculations\Comcheck.cck
COMcheck Software Version 4.0.8.1
IP11.6 Inspection Checklist
Energy Code: 2015 I E CC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions"column is provided by the user in the COMcheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
C103.2 Plans, specifications,and/or EComplies
[PR4]1 calculations provide all information Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Venture Sports Report date: 09/17/18
Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 2 of 5
Sports\Calculations\Comcheck.cck
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID 1
C405.2.1 Lighting controls installed to uniformly ❑Complies
[E L15p reduce the lighting load by at least ❑Does Not
50%.
[Not Observable
❑Not Applicable
C405.2.1 Occupancy sensors installed in ❑Complies
[E L1811 required spaces. ❑Does Not
['Not Observable
❑Not Applicable
C405.2.1, 'Independent lighting controls installed ❑Complies
C405. per approved lighting plans and all ❑Does Not
3 manual controls readily accessible and
[E L23 visible to occupants. ['Not Observable
❑Not Applicable
C405.2.2. ,Automatic controls to shut off all '❑Complies
1 :building lighting installed in all ❑Does Not
[E L22F ;buildings. ❑Not Observable
❑Not Applicable
3 'Daylight zones provided with ❑Complies
[E individual controls that control the ❑Does Not
lights independent of general area
lighting. ENot Observable
❑Not Applicable
C405.2.3, Primarysidelighted areas are ❑Complies
C405.2.3. equipped with required lighting ❑Does Not
1, controls.
C405.2.3. ❑Not Observable
2 ❑Not Applicable
[E L20p
C405.2.3, I Enclosed spaces with daylight area ;❑Complies
C405.2.3. :under skylights and rooftop monitors ❑Does Not
1, :are equipped with required lighting
C405.2.3. ;controls. ['Not Observable
3 j ❑Not Applicable
[EL21)1 I
C405.2.4 Separate lighting control devices for ❑Complies
[E L411 specific uses installed per approved ❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
C405.2.4 Additional interior lighting power ❑Complies
[E L8]1 allowed for special functions per the ❑Does Not
;approved lighting plans and is
:automatically controlled and ['Not Observable
separated from general lighting. ❑Not Applicable
C405.3 ;Exit signs do not exceed 5 watts per ❑Complies
[EL6p :face. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Venture Sports Report date: 09/17/18
Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 3 of 5
Sports\Calculations\Comcheck.cck
Section
# Final Inspection Complies? Comments/Assumptions
& Req.ID 1
C303.3, ,Furnished O&M instructions for ❑Complies
C408.2.5. :systems and equipment to the ❑Does Not
2 building owner or designated
[F117]3 representative. [Not Observable
j ❑Not Applicable
C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[F118]1 i lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts [Not Observable
are less than or equal to allowed Observable,__,
Applicable
watts.
C408.2.5. :Furnished as-built drawings for ❑Complies
1 electric power systems within 90 days ❑Does Not
[F116]3 of system acceptance.
[Not Observable
❑Not Applicable
C408.3 ;Lighting systems have been tested to ❑Complies
[F133]1 ensure proper calibration,adjustment, ❑Does Not
:programming,and operation.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Venture Sports Report date: 09/17/18
Data filename: C:\_Wilder Engineering\_Projects\Rader E ngineering\2018058-Venture Page 4 of 5
Sports\Calculations\Comcheck.cck
Project Title: Venture Sports Report date: 09/17/18
Data filename: C:\_Wilder Engineering\_Projects\Rader Engineering\2018058-Venture Page 5 of 5
Sports\Calculations\Comcheck.cck