HomeMy WebLinkAboutB18-0425_approved plans.pdf5t> God~~ rz_ h .e-e V'"'-}
w~ c--\.e~~-
1>· (~O h2)
Sketch by Apex IVD
Co ...: M
24.0'
BAS
906.0
24.0'
Co ...: M
! I I I -I I. 0 1 •o <DI woo I.;
i 144.0 ! I I L-·-·---·-----·-----·-----------1
24.0'
24.0'
LFT
304.0
150· ~I ,____ _ ___.
8.0'
own of Vail
Page 1 of 1
REVIEWED FOR CODE
COMPLIANCE
Date: -~ f -If_:__
By: C//(__ -
Code _/s
&l~r 04\-'l.';
http://property.eaglecounty.us/assessor/taxweb/sketchPicture.jsp?accountid=RO 13607.14... 09/21 /2018
PERFORMANCE™
··~ee~
The new degree of comfort'."
PERFORMANC E™ electric water heaters
feature dual copper heating elements
and a six-year warranty
Efficiency
• .92 -.93 UEF
• Isolated tank design reduces
conductive heat loss
• Dual 3800W or 4500W copper
heating elements depending on unit
Performance
• FHR: 33 -62 gallons, based on
gallon capacity
•Recovery: Up to 21 GPH at a
90° F rise, depending on model**
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over-tem perature protector cuts
off power in excess temperature
situations
Plus ...
•Temperature and pressure relief valve
included
• Low lead compliant
Warranty
• 6-Year limited warranty for tank
and parts, 1-year full in-home labor
warranty*
'See written warranty for complete details
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
PERFORMANCE
20 to 50-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
@ wnMH
See specifications chart on back.
04/17 FORM NO. THO·PE06 N Rev. 3
PERFORMANCE'" Electric Specifications
·-Nominal Rated Recovery Forst Hour Tank Height to
Gallon Gallon Model inG.P.H. Rating Height Water Conn.
Fuel Typa Description capacity Capacity Number 90• F Rise G.P.H. A B
Tall 50 45 XE50T06ST45U1 21 52 58·7/8 61·5/8
~ Medium 50 45 XE50M06ST 45U 1 21 62 48 50-1/2
;] Short 47 43 XE47SB06ST45UO' 2t 54 32 34
~ Tall 40 36 XE40T06ST45U1 2t 52 60·314 63·518
J!.: Medium 40 36 XE40M06ST 45U1 21 51 48·1/4 50·1/2
:::: Medium 40 36 XE40M06ST38U1 17 42 48·1/4 50·1/2
!.::: Short 38 35 XE38S06ST 45U 1 • 21 54 31-1/2 32-518
l:rG!i!: Short 38 35 XE38S06ST38U1 • 17 34 31-1/2 32-518
@T!..'i Short 36 33 XE36S06ST 45UO 21 46 31-1/2 33
~~ Short 36 33 XE36S06ST38UO 17 34 31·1/2 33
Elil.!ll Tall 30 27 XE30T06ST45U1 21 48 47·1/2 50·318
h Tall 30 27 XE30T06ST38U1 17 36 47·1/2 50·318
ll'~ Medium 30 27 XE30M06ST45U1 21 45 37·1/2 40·1/2
~ Short 30 27 XE30S06ST45U1 • 21 43 30 32
~ Short 30 27 XE30S06ST38U1 • 17 33 30 32
&4;: Short 28 25 XE28S06ST45UO 21 43 30 31-1/8
~ Short 28 25 XE28S06ST38UO 17 33 30 31-1/8
Short 20 NIA XE20S06ST38UO 17 NIA 31-1/2 31-1/2
• Water heater dimensions prior to installing insulation blanket that is included with water theater. The blanket adds 1-1 /2 inches to tank height
and 2 inches to tank diameter. except on model XE4 7S06T 45UO the blanket adds 5 inches to tank diameter.
Uniform Energy Factor and Energy Factor based on Department of Energy (D.0.E.) requirements.
• Heaters furnished ~th standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.
• All models equipped with heat traps.
"Recovery = wattage/2.42 x temp. rise °F. "Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH Example: 3800W = 17 GPH
2.42 x go• 2.42 x go•
''Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation.
Ship
Diameter Weight c (LBS.)
20·1/4 121
23 132
26-1/4 169
19·1/4 109
20-114 106
20·1/4 106
23 108
23 108
24-1/4 118
24-1/4 118
19·1/4 92
19·1/4 92
20·1/4 92
19·314 95
t9·314 95
23 95
23 95
17 62
HOT
WATER
CONNECTION
RELIEF VALVE
CONNECTION
The new degree of comfort:"'
--
Energy
Facto<
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
NIA
8"
-Uniform
Energy Facto<
(UEF)
0.93
0.93
0.93
0.93
0.93
0.92
0.93
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
NIA
COLD
WATER
CONNECTION
rw;M~~
l 0
B
1~
WATER CONNECTIONS ALL 314" N.P.T.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 101 Bell Road
Montgomery, Alabama 36117-4305 • www.rheem.com
04/1 7 FOAM NO. THD·PE06 N Rev. 3