HomeMy WebLinkAbout122018 Condo's 387389, 393395, 487489, and 593595 Pre & Final.pdf fld«eui LIFE SAFE T Y December 20, 2018 Mike Vaughan Fire Marshall —Town of Vail 2399 North Frontage Road West Vail, CO 81657 RE: Marriott—Vail, CO Fire Protection System —Owner Condo Units Mr. Vaughan: Rondinelli Life Safety was on-site on December 20, 2018, to perform pre-testing and final testing of the fire protection systems for the renovations of condo's 387/389, 393/395, 487/489, and 593/595. Testing began with Alarm Specialists at approximately 1:00pm and ended at 2:30pm. Below you will find my comments and observations from today. 1. The smoke detectors located in the living and guest rooms of the condo units were activated using aerosol smoke. All sounder bases activated successfully, and the device location was confirmed at the FACP. 2. In rooms with gas fireplaces, a combination smoke/carbon monoxide detector is provided. All carbon monoxide devices were activated using CO aerosol. All sounder bases on the devices successfully activated and the device location was confirmed at the FACP. 3. Manual pull stations located in the corridor were activated and the location of the pull station was confirmed at the FACP, as well as all horns located in the units successfully activated. Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn Q��dif2 LIFE SAFE T Y 4. Other observations found: • Fire sprinkler located in Unit 393 has been pulled away from the wall and will need to be addressed. • Original smoke detector located in Unit 487 is still located in guest room and will be removed once new crown molding piece is installed. •. Based upon Rondinelli Life Safety's testing and observations, it is our belief the fire protection system in units 387/389, 393/395, 487/489, and 593/595 are installed and properly working as designed. Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn Q��d«ell LIFE SAFE T Y If you have any questions or concerns, please feel free to contact me at 303.748.5846. Report Prepared By: Shaun Rondinelli Life Safety Specialist Rondinelli Life Safety Reviewed By: do c C Oz o„ 9Q, c, ♦TEPHEN O TON 6 * 47 ,` V cels �`��� FD R F - - r*) as yktAlhar Steve Rondinelli, AIA, Principal Rondinelli Life Safety Fire Protection Consultant C.C. Cody O'Kelly Principal OCG: Design. Construct. Manage PO Box 5686 Eagle, CO 81631 Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn