Loading...
HomeMy WebLinkAbout122018 Colorado Ballroom Pre-test.pdf fld«eui LIFE SAFE T Y December 20, 2018 Mike Vaughan Fire Marshall —Town of Vail 2399 North Frontage Road West Vail, CO 81657 RE: Marriott—Vail, CO Fire Protection System —Colorado Ballroom/Pre-function/Conference Rooms Mr. Vaughn: Rondinelli Life Safety was on-site on December 20, 2018, to perform pre-testing of the fire protection systems in the renovation of the Colorado Ballroom/Pre-function/Conference Rooms. Testing began with Alarm Specialists at approximately 1:00pm and ended at 2:30pm. Below you find my comments and observations from today. 1. All smoke detectors located in the ballrooms, conference, pre-function, and corridor were activated using aerosol smoke. Each device successfully reported an alarm condition at the FACP as well as verified that the device address and location matched the location in the FACP. 2. Manual pull station located in the main corridor were activated and the location of the pull station was confirmed at the FACP. All horns and strobes successfully activated, and all strobes were in sync with each other. Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn le2 k PId«ell LIFE SAFE T Y 3. Other observations noted during pre-testing: • The electrical breaker panel doors located in the Mountain View Conference Room were removed: 1` li is II1 • Some of the magnetic hold open devices still need to be installed on doors. IP V i` 1 \ Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn Q��d«ell LIFE SAFE T Y Based upon Rondinelli Life Safety's testing and observations, it is our belief the fire protection system is installed and properly working as designed and that final testing of the 5th floor can proceed as scheduled. If you have any questions or concerns, please feel free to contact me at 303.748.5846. Report Prepared By: Shaun Rondinelli Life Safety Specialist Rondinelli Life Safety Reviewed By: c;i C040, co 4,TEPHEN 0 -.wet TON 4 rte► A 47 r ACV p r4 a MA Pier Stephen Rondinelli, AIA Rondinelli Life Safety C.C. Cody O'Kelly Principal OCG: design. Construct. Manage PO Box 5686 Eagle, CO 81631 Fire Protection and Code Consulting 15272 West Warren Drive-Lakewood, Colorado, 80228 Phone: 303.807.3321 Steve@RondinelliLifeSafety.corn RondinelliLifeSafety.corn