HomeMy WebLinkAboutA18-0076_Approved Plans_1546274533.pdf RE( ir7 -j-kin Ibir Vail Fire&Emergenc, Services 12/31/18 Approved for install Property:4298 Nugget IFC2015 Occupancy Class - Residential multi- yo BATTERY CALCULATIONS sYs IEM OUTPUTS family 907.2.11 .2 Group R-3. Single or Lane CONTROL PANEL LOCATION:Mechanical Room ANNUNCIATION multiple station smoke alarms shall be PANEL: GEConcord 4 HOURS OF SUPERVISION: 24 HOURS o installed regardless of occupant load at I4IINUTESOFALARM: 15 MINUTES e Ii g all of the following locations: Address: Device Device Total 2, . I QTY PARTNUMBER Standby Alarm Standry To current H y y 1 . On ceiling or wall outside each separate 4298 Nugget Lane DESCRIPTION OF DEVICES Current Current Current G -:1 8 . 7 .F 5 sleeping area. Vail,Colorado 81657 1 GE Concord FACP 0.0000 0.0000 0.0000 0.0000 g 1) i -o " e g 8 .F m 1 ATP loon Annunciator 0.0120 0.1100 0.0120 0.1100 72 1 H v F , .2 2. In each room used for sleeping 1 SYS COSMOD2W Lower Level(1 smoke,2 smoke/CO draws included) 0.0460 0.1910 0.0460 0.1910 0 6 o Q H t 3. In each story within dwelling unit Owner 1 SYSCOSMOD2W Main Level(2 smoke, 3 smoke/CO draws included) 0.0460 02230 0.0460 0.2230 i I 6 a v *2 i i 1 o = 4298 Nugget Lane, LLC 1 SYS COSMOD2W Upper Level(2 smoke,1 smoke/CO draws included) 0.0450 0.1830 0.0450 0.1830 E ¢ ¢ a a A 4 C ¢ ° v gg 2 SYS 5603 System Sensor 135 Deg.Fixed Heat 0.0000 0.0000 0.0000 0.0000 o o ¢ ¢ A x 6 4 ? I NFPA 72 2016 29.5.1 .1 Smoke alarms shall be installed: PO Box 772 Avon, CO 81620 1 ESL 260 CO ESL Carbon Monoxide 0.0200 0.0400 0.0200 0.0400 •a c a. a. o o o .n y v 0. ` c. 1 . In all sleeping rooms and guest rooms 1 60-758 4 output snapcard relay board 0.0060 0.0400 0.0060 0.0400 6 c ,, t~ H e 4 E U 3 - i F o V 2. Outside of each sleeping area within 21 ft of door Generalcontractor: 1 SYS-MHW Interior Siren 0.0000 0.0750 0.0000 0.0750 ; ; ; ; ; w STANDBY TOTAL: 0.175 0.862 Q a a ¢ Q ¢ -s ¢ Q ¢ l~ H l~ l~ z 3. On every level, including basements. Coleman Custom Homes Smoke or Heat Detector X X X X X X X carbo Mo oxideDete or X X X X X X X Alex Coleman SUS TOTAL: 0.18 AMP 24 HOURS OF STANDBY: 24.00 HOURS SprinklerFlow X X XXXX X tel:9703764900 4. In living areas o f guest suite Sprinkler Tamper X X X X X SUB-TOTAL: 4.20 AMP HOURS G oundFault X X X X ALARM: OpenCircuit X X X X X NFPA 720 SUB-TOTAL: 0.86 AMP Low Battery x x x X X 8.4.1 .1 Carbon monoxide detectors shall be installed: 15 MINUTES OF ALARM: 0.25 HOURS AC PowerFaiture X X X X X SUB-TOTAL: 0.22 AMP HOURS Telephone LineFault-dally timertest X X X X 1 . Outside each sleeping area in immediate vicinity. CodeComplience: level 2015 International Fire Code 2. On TOTALS: Panel SilenceFeat re X X every 2016 NFPA-72 Nat.Fire Alarm Code TOTAL SUPERVISORY: requiredby 0.22 AMP HOURS ISORY: 4.20 AMP HOURS ALARM: TOTAL 3. Other location where law, code or standard. 2014 NFPA-70 Nat.Electrical Code TOTAL: 4.42 AMP HOURS OF 0.88 AMP HOURS MINIMUM gFamily HB1091 Single Homes: Carbon monoxide detectors shall BATTERY SIZE REQUIRED 5.30 AMP HOURS Levels: BAIILRIESSUPPLIED(1) 7amp hour 7.00 AMP HOURS be installed within 15 feet of bedroom door. 3Levels BA FIERY CALCULATIONS: MAIN ALARM CONTROL PANELBldg Height: VAIL FIRE INSTALLATION STANDARDS (Rev 4/16): 24'± Roof Height Occupancy Loads: / System Code Reference / Occupancy Rating: Residential- R-3 Structure: Type VB Upper Level Sq. Footage: © 0 0. ' 1 EOL RE SqFt± 5,029 Communication Type: Cellular Pr imar yPower Location: © D 00 © D 2 2 EOL RE Main Level Main Elec Panel- Breaker# Submittal Prepared By: i 0 - .4 SAE AREA: GE WEST LOWER: 1580 WEST MAIN: 2525 o Concord 4 Lower Level <' WEST UPPER: 971 FACPSuperior WEST LIVING: 5029 , PANEL © © ©� EOL RISER DIAGRAM 210Edwards Alarm #A108 Electronics Cs o ° RE PH 970-926-8788 WEST GARAGE: 833 Cellular 120 VAC FX 970-926-8790 12VDC Batt Backup br ad@super ior alarmco.COM SYMBOL DESCRIPTION FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE MONITORING DESCRIPTION CLASS STYLE TYPE SMOKE DETECTOR (PHOTOELECTRIC) 1111 HORN/SOUNDER ,35• API - DENVER COLORADO NOTIFICATION APPLIANCE CIRCUIT B Y 4 #18 AWG FPLP HEAT DETECTOR FIXED/ROR (TEMP LISTED) IRM HORN WITH STROBE I�6I'115 (NUMBER INDICATES CANDELA) REMOTE STATION New construction of a single family residence is taking place in Vail. AC POWER B Y 4 #18 AWG FPLP ANN ANNUNCIATOR15 STROBE (NUMBER SYS# 6101-1759 The residence is sprinklered. We will install smoke and carbon monoxide INITIATING DEVICE CIRCUITS B Y 4 #1s AWG FPLP WATER FLOW SWITCH t�� INDICATES CANDELA) SBUS B Y 4 #18 AWG FPLP NATIONAL INSTITUTE FOR CERTIFICATION combination devices in applicable locations and system will be zonedEOL RE END OF LINE RESISTOR IN ENGINEERING TECHNOLOGIES VALVE WITH TAMPER SWITCH Fire Protection Engineering Technology by floor. Our installation will meet Town of Vail Standards and applicable USE PLENUM RATED WIRE IN ALL PLENUM SPACES OAIM ADDRESSABLE INPUT MODULE k FIRE DEPARTMENT "KNOX" BOX Fire Alarm Systems codes. The fire sprinkler system will be monitored by the alarm system. O WIRE CHART 0 MONITORED CARBON MONOXIDE DETECTOR n_0 SMOKE/CARBON MONOXIDE COMBO DETECTOR / Scope of Work / LEGEND 0 Matt Madden NICET #134111 Level III Valid Thru 05/01/21 ORIG.12.24.18 SCALE: 1/8"=1'0" REV. DATE NOTES: A /22\ /3\ FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan, Fire Marshall Permit #: Index : PAGE NAME: Title/Bldg/Calcs/Map AHJ : artment - Flre Marshal Mike Vaughan 970 -479-2252 • • FA-0 Cover Page A 0 SHEET OF 4 1 ISIg° °F I/4 et 930 rP, Ltk j-kroD IP- Vail Fire&Emergenc, Services 12/31/18 Property:4298 Nugget Lane Address: 4298 Nugget Lane I , Vail,Colorado 81657 I III H u — EC MH. Owner Nugget Lane, LLC �A C 8' x 10.5 PO Box 772 Avon, CO 81620 C) I� �b ,� j N m Gener al Contr actor: U1 C) XV Coleman Custom Homes el ,\ Alex Coleman `� o m te1:9703764900 rXD > f- -0--Z -ff- Ut Gm _ 1 C. / \ 1 * r m I Code Complience: 2015 International Fire Code C 0 2016 NFPA-72 Nat.Fire Alarm Code 2014 NFPA-70 Nat.Electrical Code 0 L n /' / \ o o X c> ,�, Levels: \ > - - ao N 3 Levels CT I � D . � O + X z m : 4,ia ti OF go et CV fP, 4111b 1 5,I4 Vail Fire&Emergenc Services 12/31/18 Property:4298 Nugget Lane ,_ C-1.> Address: II II r 7 4298 Nugget Lane II III I II A_ Vail Colorado 81657= \ ..,..u.Daim mdri..in• ' PliW. x 11 ° U� - 4298 Nugget Lane, LLC - gg z m > I l 1 1 PO Box 772 Avon, CO 81620 Cp —1 -1 (II z Gener al Contr actor Coleman Custom Homes IIX no _ _ _f r o x Coleman t leg 03764900 I_ _I X00 m1 CO A ' P- = gb _ . T zcn p D o l; CO _ Code Complience: X „ — 2015 International Fire Code NMI N D ( cu 2016 NFPA-72 Nat.Fire Alarm Code IP m ° 2014 NFPA-70 Nat.Electrical Code 0 CJ 0�7 X �7 0 Jr — rin oK Levels: _ _ _ II I 3 Levels 1 — �� \ -0 Bld Hei ht: * / r_ g g > L _ 24'± Roof Height 0 11 M L — — — _ Occupancy Loads:g% 0 )3 0 L i7 \- Occupancy Rating: E0CC i7"11 \ Residential R-3 i — J 0 'r Structure: \ Type VB (--7, _ < x z N Sq. Footage: 1 ( . — SqFt±5,029 o Communication Type: 1 �- m x T i $_ / -F1 1 Cellular Tr m m PrimaryPower Location: kk: �`. �� �:���`. 6 . ill- a 61 of o Main Elec Panel-Breaker# ` 1 1 ---- — \\ j ( 1� 11--III—III—II Submittal PreparedBy: SAE ..,, _ Superior Alarm& Electronics c 33 o 210 Edwards Vill.Blvd.#A108 m PH 970-926-8788 —1 FX 970-926-8790 = o brad@superioralarmco.com J co m 1- 0 e MONITORING V API - DENVER COLORADO REMOTE STATION SYS# 6101-1759 IL NATNUTE IN ENGINEERING TECHNOLOGIESFOR Fire IOProtectionALINSTITEngineering Technology CERTIFICATION Fire Alarm Systems Matt Madden NICET #134111 Level III Valid Thru 05/01/21 ORIG.12.24.18 SCALE: 1/8"=1'0" REV. DATE NOTES: /2\ FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan, Fire Marshall Permit #: IiiIeixi . . PAGE NAME: Title/Bldg/Calcs/Map 2 AAHJ : Vaill - Flre Marshal Mlke 970 -479-2252 FA-2 Main Level � SHEET 3 OF 4 J ° °F I/4 et 930 rP, Ltk j-kroD IP- Vail Fire&Emergent, Services 12/31/18 Property:4298 Nugget Lane I; l 1 II II Address: 0 4298 Nugget Lane L E Vail,Colorado 81657 \ T. ,---. 4298 Nugget Lane, LLC , PO Box 772 Avon, CO 81620 m x o LAil Gener al Contr actor: cl, Coleman Custom Homes Alex Coleman te1:9703764900 a r / o cA Code Complience: 2015 International Fire Code ❑ 2016 NFPA-72 Nat.Fire Alarm Code 2014 NFPA-70 Nat.Electrical Code / cn0 N Levels: 3 Levels I I I — Bldg Height: I 24'± Roof Height I IO o _ = Occupancy Loads: _ 1N / l, 1 Occupancy Rating: + ' Residential- R-3 x o N, — Structure: id, _ Type VB C Sq. Footage: � , c A SqFt± 5,029 °J Communication Type: m $� ; rime > a I Cellular A> g N g Pr imar yPower Location: IMain Elec Panel- Breaker# front ' .g., i Submittal Pr epar ed By: FA ' s __ SAE 0 z SuperiorAlarm& Electronics 1 210 Edwards Vill.Blvd.#A108 PH 970-926-8788 FX 970-926-8790 — = brad@superioralarmco.com MONITORING API - DENVER COLORADO REMOTE STATION SYS# 6101-1759 NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES Fire Protection Engineering Technology Fire Alarm Systems Matt Madden NICET #134111 Level III Valid Thru 05/01/21 ORIG.12.24.18 SCALE: 1/8"=1'0" REV. DATE NOTES: A /2\ A FINAL INSP. AS BUILTS: AHJ: Vail Fire Department Mike Vaughan, Fire Marshall Permit #: Index : PAGE NAME: Title/Bldg/Calcs/Map AAHJ : Vail Fire - Fire Marshal Mike 970 -479-2252 FA-3 Upper Level SHEET 4 OF 4 .1