Loading...
HomeMy WebLinkAboutA18-0003_approved documents_1526675052.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Fire - Construction Permit A18-0003 Issued: 05/18/2018 TOWN OF VAIL Property Information Address: 598 VAIL VALLEY DR (210108109002) ( 210108109002 ) Unit #: Parcel Number: 210108109002 Legal Description: Subdivision: VAIL VILLAGE FILING 7 TRACT B, PART OF Contacts Contact Type: Applicant Full Name: John Brinker Address: PO Box 6205 PO Box 6205 Vail, CO 81657 Phone: 9708279120 Contact Type: Property Owner Full Name: SKI CLUB VAIL Address: Phone: None Contractor Contractor Type: Fire Protection Company: Meridian Intermountain/Vail Electronics State License #:Phone: 970-748-8888 Project Information Project Name: Ski Club Vail 2017 Project Description: Install new fire alarm system Fees Paid Account #: 001-0000.31111.00 - Fire Alarm Permit Fee Fee Amount:$547.13 Account #: 001-0000.31123.00 - Fire Alarm Review Fee Fee Amount:$288.00 Total Paid:$835.13 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet 252-Point and 504-Point Addressable Fire Alarm Control Panel Models FC922 and FC924 Answers for infrastructure CerberusTM PRO Fire Safety & Security Products Cerberus PRO Fire Safety 9815 FACP for mid-size buildings Product Overview The Cerberus PRO Fire Safety Model FC922 (252- point) and FC924 (504-point) addressable FACP is designed to meet the fire-protection needs of mid- size buildings. This advanced panel offers features typically required in mid-size buildings in a package that is easy to install and competitively priced. Additionally, Models FC922 and FC924 are networkable, allowing the systems to fulfill the growing fire-protection needs of the building. The programming software for the 252 / 504-point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM). The following Cerberus PRO system components are used in the 252-point / 504-point FACP:  Operating units Periphery boards  Power supplies System enclosures Other options are available to meet specific needs of the customer. Models FC922 and FC924 are CSFM (Listing No.: 7165-0067:0259) and FDNY (Certificate of Approval: #6104) Approved. Specifications Operating Interface Unit The Operating Interface Unit (Model FCM2018-U3 or Model FCM019-U3) functions as the operating interface and central microprocessor for Models FC922 and FC924. Either operating interface unit provides multi-use capability for each end-user to efficiently ‘Acknowledge’ events; to quickly control the NACs of the FACP, and to permit a manual reset of the respective system. Detailed information about the nature and location of the events can also be displayed, via a backlit, 2” ─x─ 4-3/4” LCD screen and the four-way navigation push button at the top of the panel. Periphery Boards The periphery boards (Models FCI2016-U1 and FCI2017-U1) serve as the main operating components for the 252 / 504-point FACP. Each module operates and monitors input-device identity; as well as controls the signaling-line circuits that communicate with smoke detectors and other field devices (i.e. − C-NET).  Addressable fire alarm control panel (FACP) intended for mid-size buildings  Comprised of the following system components:  Operating units  Periphery boards  Power supplies  System enclosures  System features:  Supports 252-to-504 addressable devices:  One (1) to four (4) ‘Class B’; one (1) to two (2) ‘Class A’ for Model FC922  One (1) to eight (8) ‘Class B’; one (1) to four (4) ‘Class A’ for Model FC924  Includes one (1) ‘Class A’ or two (2) ‘Class B’ notification appliance circuits (NACs)  Resettable and non-resettable 24VDC, [nominal] auxiliary power  Optional connectivity to a leased-line / city-tie module  Releasing module supports activation of releasing valves in pre- action / deluge systems / agent release  Off-normal warning message prior to reset  Fast and easy set-up with auto-configuration feature  Optional digital alarm communication transmitter (DACT)  UL 864 9th Edition Listed; CSFM & NYC Fire Department Approved Cerberus PRO two-height-unit enclosure with two (2) windows s Industry, Inc. Building Technologies Division CerberusTM PRO Specifications ─ (continued) Power Supplies All functions are supported by the power supplies (Model FP2011-U1 or Model FP2012-U1), which eliminate the need for external power supplies. Further, the 170-Watt power supply (Model FP2011-U1) and 300-Watt power supply (Model FP2012-U1) provide primary, 24VDC nominal power for normal operation to Models FC922 and FC924. Both power supplies are filtered and regulated. Model FP2011-U1 is rated at 6.5 Amps, and Model FP2012-U1 is 11.5A rated. The 170-Watt power supply incorporates a 4.0A, non- resettable slow-blow fuse on the primary input, and includes a built-in AC-line filter for surge and noise suppression. Model FP2011-U1 mounts in the panel’s enclosure, and there are no serviceable Cerberus PRO Fire Safety parts to be maintained. The 300-Watt power supply incorporates two (2) 6.3A replaceable, non-resettable slow-blow fuses on the primary input and includes a built-in AC line filter for surge and noise suppression. Model FP2012-U1 mounts in the panel’s enclosure, and there are no serviceable Cerberus PRO Fire Safety parts to be maintained. System Enclosures The Cerberus PRO fire-alarm enclosures and their accessories provide a complete set of hardware for mounting all Cerberus PRO main-system and remote terminal cards and modules. The hardware allows this Cerberus PRO system to be configured for a variety of applications, as well as for future system upgrades. Included in the enclosure series are back box and door sets; removable mounting plates and clear lenses, as well as blank plates for use with the enclosure doors. All enclosures come with ground straps for the inner and outer doors, shield termination lugs, grounding lugs, and tie wrap lances for securing wire. All Cerberus PRO height- unit enclosures can also mount system back-up batteries up to 33AH in capacity. Models FC922 and FC924 utilize a two-height-unit enclosure. The following components comprise a complete two-height-unit enclosure:  One (1) back box, (Model FHB2002-U1 / R1)  One (1) or two (2) inner doors, (Models FHD2004-U1 or FHD2005-U1)  One (1) outer door, (Model FHD2002-U3 / R3 or FHD2003-U3 / R3)  One (1) or two (2) clear windows, (Model FHD2006-U1) Note: One (1) window is installed for Model FHD2002-U3 / R3 outer door, and two (2) windows are required for Model FHD2003-U3 / R3. The approximate size for each two-height-unit enclosure is: 27.5" (70cm.) high; 21.5" (54.6cm.) wide, and 5.75" (14.6cm.) deep. The weight, without any attached components, is approximately 6.3 Lbs. (2858 g). Additionally, the two-height-unit enclosure supports the following optional components:  Enclosure trim kit (for flush-mounting)  Battery bracket (to comply with seismic certification)  DIN rail kit (provides connection between internal-system wiring and field wiring) Optional Accessories NAC Expansion Module The NAC expansion module (Model FCI2011-U1) provides either of the following additional NACs to the 252 / 504-point panel:  one (1) ‘Class A’, or  two (2) ‘Class B’ NACs Each NAC is rated at 3 Amps. Each NAC expansion module is monitored for open-line and short-circuit conditions. Digital Alarm Communication Transmitter (DACT) The DACT is used to provide communication between Models FC922 and FC924 and with either a central or remote monitoring station. The Model FCA2015-U1 module mounts directly on the back enclosure and connects to the periphery boards. The DACT enables remote transmission of alarms and events via a public telephone line. Releasing Module The releasing module (Model XCI2001-U1) supports activation of releasing valves in pre-action / deluge systems (including double-interlock pre-action systems, or SinorixTM engineered fire suppression systems). Activation can be event-controlled or performed by addressable manual pull stations. The releasing module is installed on the periphery board, and supports ‘Class B’ releasing circuits. When installed on Models FC922 / FC924, the releasing module contains an integral manual-disconnect switch for releasing circuits. This essential feature protects the releasing circuits from accidental discharge during maintenance. Leased-Line / City-Tie Module Model FCI2020-U1, which is installed on the periphery board of the FACP, provides a local-energy output for municipal call-box connection, and gives a reverse- polarity output for leased-line connection. When used for connection to a municipal call box, the city-tie function supports Alarm-event transmission. When used for leased-line connection, the module supports two (2) leased telephone lines for transmitting Alarm, Trouble and Supervisory events. s Industry, Inc. Building Technologies Division CerberusTM PRO Specifications ─ (continued) Network Module The C-WEB network module (Model FN2001-A1) is used to network up to 16 FACPs, or one (1) fire terminal, via the C-NET system bus. Model FN2001-A1 is plugged into the Operating Unit (Model FCM2018-U3 or Model FCM2019-U3). Model FN2001-A1, which connects to a system input / output bus, has ground-fault monitoring, as well as an integrated degrade-mode feature. Redundant networking is accomplished with one (1) network module per panel [Simple-Loop Trouble]. There is electrical isolation between the system bus and the FACP. Remote Display Terminals The Remote Display Terminals (Models FT2014-U3 / R3 and FT2015-U3 / R3) are remote annunciators that show the existing status of Models FC922 / FC924. Light-emitting diodes (LEDs) will illuminate for any given Alarm, Supervisory and Trouble Cerberus PRO-system event. A 2” ─x─ 4-3/4” LCD screen will give details of the event in alphanumeric form. The display screen can be scrolled, via the four-way navigation button, to reveal additional events. Model FT2014-U3 / R3 is a display-only remote annunciator that has one (1) button used to silence the local sounder. Model FT2015-U3 / R3 has three (3) control buttons for ‘acknowledging’ events, ‘silencing’ audible circuits and ‘resetting’ the system. Additionally, there are three (3) user-programmable buttons available. Model FT2015-U3 / R3 has an integral key switch that enables the control buttons to operate. The remote display terminals are remotely connected to Models FC922 and FC924, via the RS─485 interface. Models FC922 and FC924 require the Model FCA2016- A1 RS─485 module to provide communication to the remote display terminals. Model FCA2016-A1 supports Style 4 or Style 6 wiring. Up to eight (8) modules can be supported on a RS─485 bus. The remote display terminals require 24VDC [nominal] power, and the necessary power can be provided from this Cerberus PRO FACP or from another UL Listed, 24VDC power source. Remote Peripheral Module The Remote Peripheral Module (Model FCA2018-U1) provides a means of connecting this Cerberus PRO FACP to Model PAL-1 for creating hard copies of system- status and configuration reports. Model FCA2018-U1 is a supervised, intelligent module that has built-in transient protection and plain-decimal addressing. Model FCA2018-U1 is remotely connected to the Model FCA2016-A1 RS─485 communication bus from any Cerberus PRO Fire Safety system enclosure. Model FCA2018-U1 uses Class B (Style 4) or Class A (Style 6) wiring, and provides two (2) RS─232 serial ports and a one (1) parallel port, thus connecting to Model PAL-1. Temperature and Humidity Range Models FC922 and FC924 are UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120+/-3°F (49+/-2°C) to 32+/-3°F (0+/-2°C) and a relative humidity of 93+/-2% at a temperature of 90+/-3°F (32+/-2°C). Related Documentation Product Data Sheet Number Cerberus PRO operating units 9801 Cerberus PRO periphery boards 9802 Cerberus PRO fire terminals 9803 Cerberus PRO DACT 9804 C-WEB / C-NET Network Module 9805 Cerberus PRO power supplies 9806 Cerberus PRO enclosures 9807 NAC expansion module 9808 Cerberus PRO releasing module 9809 Leased-Line / city-tie module 9810 Remote periphery module 9811 Remote display terminals 9812 Single / multi-mode fiber modules 9814 LED / Blank option modules 9816 Details for Ordering Model Number Part Number Description FCM2018-U3 S54400-C40-A1 Cerberus PRO Operating Interface Unit FCM2019-U3 S54400-C41-A1 Cerberus PRO Operating Interface Unit FCI2016-U1 S54400-A55-A1 Cerberus PRO Periphery Board {for 252-point system} FCI2017-U1 S54400-A56-A1 Cerberus PRO Periphery Board {for 504-point system} FP2011-U1 S54400-Z59-A1 170-Watt Power Supply FP2012-U1 S54400-Z60-A1 300-Watt Power Supply FHB2001-U1 S54400-B47-A1 1HU Back Box, Black FHB2001-R1 S54400-B47-A2 1HU Back Box, Red FHD2001-U3 S54400-B45-A1 1HU Outer Door, Black FHD2001-R3 S54400-B40-A1 1HU Outer Door, Red FHB2002-U1 S54400-B48-A1 2HU Back Box, Black FHB2002-R1 S54400-B48-A2 2HU Back Box, Red FHD2002-U3 S54400-B32-A1 2HU Outer Door w/ 1 Window, Black FHD2002-R3 S54400-C53-A1 2HU Outer Door w/ 1 Window, Red FHD2003-U3 S54400-C42-A1 2HU Outer Door w/ 2 Windows, Black FHD2003-R3 S54400-B46-A1 2HU outer door w/ 2 windows, Red FHD2004-U1 S54400-B52-A1 Inner Door, Black FHD2005-U1 S54400-B53-A1 Inner Door, Solid Black FHD2006-U1 S54400-C46-A1 Clear-Lens Window Optional Accessories Model Number Part Number Description FCI2011-U1 S54400-A54-A1 NAC Expansion Module XCI2001-U1 S54400-A69-A1 Releasing Module FCI2020-U1 S54400-A57-A1 Leased-Line / City-Tie Module FCA2018-U1 S54400-A65-A1 Remote Peripheral Module FCA2016-A1 S54400-A39-A1 RS─485 Module s CerberusTM PRO Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] November 2012 ─ Supersedes sheet dated 4/2012 (Rev. 2) Details for Ordering ─ (continued) Optional Accessories ─ (cont.’d) Model Number Part Number Description FT2014-U3 S54400-B80-A1 Remote Display Terminal FT2014-R3 S54400-B73-A1 Remote Display Terminal, Red FT2015-U3 S54400-B88-A1 Remote Display Terminal FT2015-R3 S54400-B16-A1 Remote Display Terminal, Red FN2006-U1 S54400-A61-A1 Single-Mode Fiber-Optic Module FN2007-U1 S54400-A62-A1 Multi-Mode Fiber-Optic Module FCM2022-U3 S54400-C44-A2 Blank Option Module FCM2023-U3 S54400-C45-A2 LED Option Module FCA2015-U1 S54400-A63-A1 Digital Alarm Communication Transmitter (DACT) FTI2001-A1 S54400-A58-A1 Fire Terminal Board FN2001-A1 S54400-A60-A1 C-WEB / C-NET Network Module Electronics Packages Model Number Part Number Description 252-Point Fire System with 170 Watt Power Supply and standard operator interfaces FC922-US S54400-C14-A1 Includes: FP2011-U1 (1 Qty.) FCI2016-U1 (1 Qty.) FCM2018-U3 (1 Qty.) 504-Point Fire System with 170 Watt Power Supply and standard operator interfaces FC924-US S54400-C15-A1 Includes: FP2011-U1 (1 Qty.) FCI2017-U1 (1 Qty.) FCM2018-U3 (1 Qty.) 252-Point Fire System with 170 Watt Power Supply and standard operator interfaces (with 24-zone LEDs)FC922-UE S54400-C16-A1 Includes: FP2011-U1 (1 Qty.) FCI2016-U1 (1 Qty.) FCM2019-U3 (1 Qty.) 504-Point Fire System with 170 Watt Power Supply and standard operator interfaces (with 24-zone LEDs)FC924-UE S54400-C17-A1 Includes: FP2011-U1 (1 Qty.) FCI2017-U1 (1 Qty.) FCM2019-U3 (1 Qty.) Network Terminal w/ standard operator interface FT924-US S54400-C18-A1 I ncludes:FT I2001-A1 (1 Qty.) FCM2018-U3 (1 Qty.) Network Terminal w/ standard operator interface (with 24-zone LEDs)FT924-UE S54400-C19-A1 Includes:FTI2001-A1 (1 Qty.) FCM2019-U3 (1 Qty.) 252-Point Fire System with 300 Watt Power Supply and standard operator interfaces FC922-UT S54400-C20-A1 Includes:FP2012-U1 (1 Qty.) FCI2016-U1 (1 Qty.) FCM2018-U3 (1 Qty.) 504-Point Fire System with 300 Watt Power Supply and standard operator interfaces FC924-UT S54400-C21-A1 Includes:FP2012-U1 (1 Qty.) FCI2017-U1 (1 Qty.) FCM2018-U3 (1 Qty.) 252-Point Fire System with 300 Watt Power Supply and standard operator interfaces (with 24-zone LEDs)FC922-UF S54400-C22-A1 Includes:FP2012-U1 (1 Qty.) FCI2016-U1 (1 Qty.) FCM2019-U3 (1 Qty.) 504-Point Fire System with 300 Watt Power Supply and standard operator interfaces (with 24-zone LEDs)FC924-UF S54400-C23-A1 Includes:FP2012-U1 (1 Qty.) FCI2017-U1 (1 Qty.) FCM2019-U3 (1 Qty.) Distributed Power Supply  NAC Extender (Model PAD-4 series) 3363 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety & Security Products FACP Accessories PAD-4 Distributed Power Supply Unit Notification Appliance Circuit Extender Models PAD-4-ENCL, PAD-4-MB (with FP2011-U1, FP2012-U1 power supplies) Product Overview Used with Siemens  Fire Safety fire alarm control panels (FACPs), the Distributed Power Supply PAD-4 Unit is a NAC expander with a built-in, auxiliary- power output. Each PAD-4 unit distributes additional power in buildings for audible and visual indicators that conform to the Americans with Disabilities Act (ADA). PAD-4 also has the following features:  NACs  Signal-input circuits  Battery-charging circuit  Trouble relays for remote monitoring  Diagnostic light-emitting diodes (LEDs)  Alternating Current (AC) power connection The Siemens NACs, which connect with alarm signaling devices, have been designed to provide the highest level of reliability and performance. Signal coding on the circuits is accomplished through integrated circuits (rather than relays), which eliminates mechanical wear on the output circuits. The PAD-4 unit provides consistent 24VDC output voltage to each NAC − independent of voltage fluctuations on the primary or secondary power source. As a result, a larger voltage drop and a greater wire length for each NAC are supported by each PAD-4. Specifications This version of the Siemens Distributed Power Supply Unit can be configured in the following manner that makes the outputs easily programmable:  ‘STEADY’ outputs  Synchronized strobe outputs  American National Standards Institute (ANSI) Temporal 3  ANSI Temporal 4 [for carbon monoxide (CO) alarm signal] There are also two (2) inputs used to control the activation of the four (4) outputs. Programming can be set so one (1) input will silence the audible signal on Siemens Models ‘AS’-series, ‘NS’-series, or ‘ZH’- series horn and horn-strobes while the strobes remain active. ARCHITECT AND ENGINEER SPECIFICATIONS  Multi-module mounting in System 3™ enclosures  Multiple modules share battery set  ADA Compliant  UL 864 9 th Edition Listed, CSFM Approved; UL 1481 Listed (for power supplies) ‘Class A’ Adapter Card [Model PAD-4-CLSA] Main Board [Model PAD-4-MB]  Four (4) ‘Class B’, power-limited notification appliance circuits (NACs)  ‘Class A’, field-selectable wiring  Each unit can support an optional module (Model PAD-4-CLSA) that converts two (2) built-in ‘Class A’ NACs into four (4) ‘Class A’ NACs  Up to 3 Amps of auxiliary-power output  Optional built-in strobe synchronization  Supports coded audible signals, including Temporal 3, Temporal 4 patterns  Battery supervision and control  ‘Form C’ general Trouble / AC Fail monitoring contact  Power supplies support NAC power  Up to 6A used with Model FP2011-U1  Up to 9A used with Model FP2012-U1  24VDC output voltage  Ground-fault detection  Advanced microprocessor control  Uses Flash memory-based system firmware  Optional system-diagnostic and firmware-upgrade tool Unit Enclosure [Model PAD-4-ENCL] s Industry, Inc. Building Technologies Division Specifications ─ (continued) Operation of each PAD-4 unit is controlled by firmware stored in Flash memory on the main board, as well as the storage of a 10-event log, which can be viewed via Model PAD-4-FDT. In the event that an upgrade to the system firmware is required, the firmware can be transferred to the system without the replacement of firmware chips. An optional firmware-download software tool, Model PAD-4-FDT, can be used for system diagnostic testing of the following:  Primary-power voltage readouts  Current draw for power charger  Configuration switch settings  Firmware version  Battery voltage When the tool is in communication with Model PAD- 4-MB, the ‘Test Mode’ LED is illuminated. Model PAD-4-LUA is a USB serial port adapter that is required for tool-kit operation. Each NAC extender supervises a variety of functions including:  Low AC power  Battery-voltage level  Earth ground-fault conditions All power can be directed to two (2) ‘Class A’ or four (4) ‘Class B’ power-limited NACs. Each NAC supports up to 3 Amps per circuit. Either one (1) or two (2) inputs can control four (4) outputs, which are compatible with all Siemens  Fire Safety 24VDC alarm signaling devices. In cases where ‘Class A’ circuits are used, an optional Model PAD-4-CLSA module can be added, providing two (2) additional ‘Class A’ outputs to each PAD-4 unit. Each NAC extender is also capable of operating other parts of a Siemens fire alarm system, such as door holders, via 3 Amps @ 24VDC max of power-limited auxiliary output. When the output activated, the total power available cannot exceed 6 Amps when used with Models FP2011-U1 or 9 Amps when used with FP2012-U1. Trouble conditions are monitored through each unit’s two (2) inputs. In addition, one (1) ‘Form C’ Trouble contact is provided for monitoring each unit that is connected through the input of a Siemens FACP. Therefore, the user has the option of connecting a PAD-4 NAC extender unit into a NAC of a Siemens FACP, or the unit may be monitored with a Model TRI-series monitoring module on a Siemens intelligent fire system. A separate ‘Form C’ Trouble contact is used exclusively with each NAC extender to indicate AC Fail Trouble events on the NAC extender. Each unit is packaged in its own sheet-metal enclosure with sufficient space to house up to 7AH battery sets. The enclosure (Model PAD-4-ENCL) is available in red. The battery charger used in each unit can energize batteries of up to 18AH. Though, when battery sets greater than 7AH are required, the battery set must be housed in a System 3 enclosure or a separate UL Listed battery enclosure. System 3 enclosures may also be used to house multiple Model PAD-4 units in a single enclosure, via the Model S3AP Adapter Plate. Two (2) units are capable of sharing the same battery set when mounted in the same enclosure. Model S3AP can also be used to mount the PAD-4 main board and 170-Watt power supply (Model FP2011-U1) into a PAD-3 enclosure. Each Model PAD-4 unit complies with seismic certification, pursuant to the following:  ASCE Standard 7, 2005 Edition  International Building Code, 2006 Edition  California Building Code, 2007 Edition  ICC-ES AC 156, effective 2007  OSHPD preapproved, under: OSP-0057-10 − OSHPD CAN 2-1708A.5, Rev. 3 Each Model PAD-4-series unit also complies with seismic certification, pursuant to ASC / SEI 7-05, Section 13.2.2, when used with the PAD-4 battery bracket (Model PAD4-BATT-BRKT). Configuration Options Option Input[s] Output Controls Circuit Types 1 Input 1 All outputs ‘Class B’ circuits Input 1 All outputs ‘Class B’ circuits2 Input 2* Silences horns on Output 1 — Input 1 Outputs 1 and 2 ‘Class B’ circuits3Input 2 Outputs 3 and 4 ‘Class B’ circuits Input 1 Output 1 ‘Class B’ circuits4Input 2 Outputs 2, 3 and 4 ‘Class B’ circuits 5 Input 1 Outputs 1 through 4 ‘Class A’ circuit pairs Input 1 Outputs 1 through 4 ‘Class A’ circuit pairs6 Input 2* Silences horns on Output 1 — Input 1 Outputs 1 and 2 ‘Class A’ circuit pairs7 Input 2 Outputs 3 and 4 ‘Class A’ circuit pairs * denotes when used with Siemens Model ‘AS’,’ NS’ or ‘ZH’--series horn / strobe devices s Industry, Inc. Building Technologies Division Indicator Lights AC Power ON: Green AUX / PS: Yellow Ground Fault: Yellow Output 1 Trouble: Yellow Output 2 Trouble: Yellow Output 3 Trouble: Yellow Output 4 Trouble: Yellow Test Mode: Yellow Technical Data AC Fail Trouble Contact Rating: { ‘Form A’ – Normally Closed (N.C) } 2.0A @ 30VDC, max. [resistive] Basic Trouble Contact Rating: { ‘Form C’ } 2.0A @ 30VDC, max. [resistive] 3.0A per circuit, max. 6A, max. {via Model FP2011-U1}Alarm Current: { for NACs and auxiliary power }9A, max. {via Model FP2012-U1} Ambient Temperature: 32° ─ 120° F (0° ─ 49° C) Relative Humidity: Up to 93% @ 86° F (30° C); non-condensing Auxiliary Power Circuit: One (1) circuit @ 3A max. Battery Charging Capacity: 18AH Input Circuits / Configurations: Two (2) ‘Class B’ supervised or Two (2) ‘Class A’ supervised Input Current: 7.0mA, max. Input Voltage Range: 16 ─ 33VDC / VFW Installation Environment: Indoor, dry o Supervised, power-limited o 1.0mA standby current, max. o Four (4) circuitsNACs: o 2K ohms (+), 8K ohms (-) 24VDC @ 6 Amps (with Model FP2011-U1);Total Output Power: 24VDC @ 9 Amps (with Model FP2012-U1) o Two (2) ‘Class A’;  Up to four (4) ‘Class A’ (via Model PAD-4-CLSA) o Four (4) ‘Class B’; Output Circuits / Configurations: o One (1) Class A, Two (2) Class B; Single-Unit Dimensions: { W -x- H -x- D } Model PAD-4-ENCL 13.5” ― x ― 18.75” ― x ― 3.25” (34.3 cm. -x- 47.6 cm. -x- 8.3 cm.) Color: Model PAD-4-ENCL Red Temperature and Humidity Range Each PAD-4 Distributed Power Supply Unit is UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120+/-3°F (49+/-2°C) to 32+/-3°F (0+/-2°C) and a relative humidity of 93+/-2% at a temperature of 90+/-3°F (32+/-2°C). Details for Ordering Model Number Part Number Description PAD-4-ENCL 500-050081 PAD-unit enclosure PAD-4-MB 500-650217 PAD-unit main board FP2011-U1 500-450222 170-Watt power supply FP2012-U1 S54400-Z60-A1 300-Watt power supply — System Kits — Model Number Part Number Description PAD4-6A S54339-A1-A1 Complete 6A PAD-4 kit with: − One (1) Unit Enclosure, PAD-4-ENCL − One (1) Main Board, PAD-4-MB − One (1) 170W power supply, FP2011-U1 PAD4-6A-CLSA S54339-A2-A1 Complete 6A PAD-4 kit with: − One (1) Unit Enclosure, PAD-4-ENCL − One (1) Main Board, PAD-4-MB − One (1) 170W power supply, FP2011-U1 − One (1) ‘Class A’ Adapter Card, PAD-4-CLSA PAD4-9A S54339-A3-A1 Complete 9A PAD-4 kit with: − One (1) Unit Enclosure, PAD-4-ENCL − One (1) Main Board, PAD-4-MB − One (1) 300W power supply, FP2012-U1 PAD4-9A-CLSA S54339-A4-A1 Complete 9A PAD-4 kit with: − One (1) Unit Enclosure, PAD-4-ENCL − One (1) Main Board, PAD-4-MB − One (1) 300W power supply, FP2012-U1 − One (1) ‘Class A’ Adapter Card, PAD-4-CLSA — Optional Accessories — Model Number Part Number Description PAD4-BATT-BRKT S54430-B4-A1 Battery bracket for NAC expander PAD-4-LUA S54389-C1-A1 PAD-4 Laptop-Upload Adapter PAD-4-CLSA 500-850254 ‘Class A’ Adapter Card S3AP 500-650257 PAD-4 NAC expander adapter plate (for use with PAD-3 and System 3 enclosures) s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.usa.Siemens.com/Fire (SII-FS) Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 October 2013 Supersedes sheet dated 8/13 (Rev. 2) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet Cerberus® PRO Fire Safety Products Photoelectric Smoke Detector Model OP921 Answers for infrastructure Intelligent Detection Devices 9902 Photoelectric Smoke Detector Product Overview The Photoelectric Smoke Detector (Model OP921) uses state-of-the-art microcontroller circuitry and surface- mount technology for maximum reliability. Model OP921 incorporates an optical sensor using a light- scattering detection principle. The device utilizes advanced software algorithms to analyze the signals, and provides highly stable and accurate smoke detection. Further, Model OP921 uses state-of-the-art microprocessor circuitry with error check; detector self- diagnostics, and supervision programs. Field-Device Programmer / Test Unit Model OP921 is compatible with the Siemens field- device programmer / test unit (Model 8720 / DPU), which is a compact, portable, menu-driven accessory for electronically programming and testing detectors easily and reliably. Model 8720 / DPU eliminates the need for cumbersome, unreliable mechanical programming methods, such as dials or switches, and reduces installation and service costs by electronically programming and testing the detector prior to installation. For proper operation of the field-device programmer / test unit, the technician selects the accessory’s program mode, and enters the desired address. In turn, Model 8720 / DPU automatically sets and verifies the address, as well as tests the detector. When in the ‘test’ mode, Model 8720 / DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Model 8720 / DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment from practically any location. • Compatible with Siemens Model ‘H’-series devices on the same loop (with Cerberus PRO fire-alarm control panels [FACPs] or FireFinder® XLS FACPs) • Compatible with Model 8720 / DPU (device programmer / loop tester) • Utilizes advanced microprocessor-based signal processing • Extended temperature and humidity operating range • Each detector is self-testing:  Self monitored for sensitivity within UL Listed limits  Complete diagnostics performed every 10 seconds • Polarity insensitive utilizing SureWireTM technology • Compatible with Model DB-11−series mounting bases • Tri-color detector-status LED with 360° viewing • Field-selectable application sensitivity profiles • Remote sensitivity-measurement capability • Utilizes advanced signal processing • Superior EMI / RFI immunity • RoHS compliant • Automatic environment compensation • UL268A Listed [for direct air-duct use], ULC Listed; FM (#3230, 3210 ) and CSFM (#7272-0067:0258) Approved s Industry, Inc. Building Technologies Division Cerberus® PRO Product Overview ─ (continued) Model 8720 / DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment from practically any location. Model OP921 is a plug-in, two-wire and addressable photoelectric smoke detector. Model OP921 is Underwriters’ Laboratories Listed [ UL268A Listed for direct in-air duct usage]. Each detector consists of a dust-resistant photoelectric chamber and microprocessor-based electronics with a low-profile plastic housing. Every Model OP921 fire detector is shipped with a protective dust cover: 1. Dust cover 2. Smoke detector Operation Model OP921 is a wide-spectrum, photoelectric smoke detector incorporating an infrared light-emitting diode (IRLED), and infrared light-sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non-smoke, airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles, and is received by the photodiode: 1. Labyrinth 2. Optical transmitter 3. Optical receiver Sensitivity Settings Application Parameter Sets Model OP921 provides four (4) pre-programmed sensitivity parameter sets that can be selected by the FACP to match the expected application or environmental conditions: • Sensitive • Standard • Robust • Air-duct Sensitive: This application parameter set is practically suitable for areas where few misleading sources of false alarm are present, and is appropriate where priority is given to detecting open fires as soon as possible (e.g. – typically a clean application with controlled environmental conditions.) Standard: This application parameter set is practically apt for normal office, hotel-lobby-type applications, and is the default setting. Robust: This application parameter set offers improved resistance to false alarms in areas where misleading sources, such as cigarette smoke or exhaust fumes, may cause a nuisance alarm. Air-Duct: This application parameter set is used when the detector is used a UL268A (DI) compliant direct in- air duct application without a duct housing. Model OP921 does not require a field sensitivity test. Model OP921 is UL Listed as a self-testing device and complies with NFPA 72 as a self monitoring detector and control panel arrangement. This parameter set is also used when Model OP921 is used in air-duct housings (Models FDBZ492 and FDBZ492-HR). The visible LED flashes green every 10 seconds to indicate communication with the FACP, and to notify Model OP921 has passed its self-test. Should Model OP921 sense a fault or failure within its system, the LED will flash amber, and the detector will transmit the data to the FACP. A quick visual inspection is sufficient to indicate the condition of Model OP921 at any time. If more detailed information is required, a printed report can be provided from the compatible FACP, indicating the status and settings assigned to each individual detector. When Model OP921 moves to Alarm mode, the detector will flash red and continue flashing until the system is reset at the FACP. At that same time, any user-defined, system-alarm functions programmed into the system are activated. Model OP921 contains a tri-color LED indicator, capable of flashing any one (1) of three (3) distinct colors: green, yellow, or red. During each flash interval, the microprocessor-based detector monitors the following: 1 2 s Industry, Inc. Building Technologies Division Cerberus® PRO Operation ─ (continued) • Smoke sensitivity is within the range indicated on the nameplate label • Smoke in its sensing chamber • Internal sensors and electronics are functional Based on the monitoring results, the LED indicator flashes the following colors based on the following conditions: Flash Color Condition Flash Interval (in seconds) Green*: Normal supervisory operation. Smoke sensitivity is within rated limits. 10 Yellow:Detector is in trouble and needs replacement.4 Red: Alarm condition. 1 No Flash: Detector is not powered. ─ ─ * LED can be turned OFF. Please follow the corresponding description of the panel used. A quick, visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the respective Cerberus PRO FACP that indicates the status and settings assigned to each individual detector. Installation All Model OP921 detectors use a surface-mounting base, Model DB-11 or Model DB-11E, which mounts on a 4-inch octagonal, square or single-gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. The Model DB-11 base can be used with the optional Model LK-11 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has decorative plugs to cover the outer- mounting screw holes. Model OP921may be installed on the same initiating circuit with the Siemens Model ‘H’-series detectors [when used with the Cerberus PRO FACPs] ─ • Model HFP-11 • Model ‘HMS’-series manual stations • Model ‘HTRI’-series interfaces • Model HCP output-control devices • Model ‘HZM’-series of addressable, conventional zone modules Application Data Installation of Model OP921detectors requires a two-wire circuit. In many retrofit cases, existing wiring may be used. ’T-tapping’ is permitted only for Style 4 (Class B) wiring. Model OP921 is polarity insensitive, which can greatly reduce installation and debugging time. Model OP921 can be applied within the maximum 30- feet center spacing (900 sq. ft. areas), as referenced in NFPA 72. This application guideline is based on ideal conditions ─ specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air-conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens ─ Fire Safety distributor or sales office whenever you need assistance applying Model OP921 in unusual applications. Be sure to follow NFPA guidelines and UL Listed / ULC Listed installation instructions ─ included with every Siemens − Fire Safety detector ─ and local codes as for all fire- protection equipment. Technical Data Operating Temperature +32°F (0°C) to 120°F (49°C) Range: Relative Humidity: 0 ─ 95%; non-condensing Air Pressure: No effect Air Velocity: 0 ─ 4,000 ft. / min (0-20m / sec) Input Voltage Range: 16VDC − 30VDC Alarm Current (max.): 280μA Standby Current (max.): 280μA, max. (average) Maximum Spacing: 30-foot centers (900 sq. ft.), per NFPA 72 Detector Weight: 0.317 lbs. (0.144 kg.) Mechanical Protection Guard: UL Listed / ULC Listed [with STI Guard Model STI-9604] s Cerberus® PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] March 2015 ─ Supersedes sheet dated 11/2013 (Rev. 5) Mounting Diagram Dimensions Detector Compatibility Table Model Data Sheet Number Description — 6300 FireFinder® XLS (system overview) FC901 9813 50-point panel FC922 9815 252-point system (networkable) FC924 9815 504-point system (networkable) FV922 9821 252-point intelligent voice communication system FV922 9821 504-point intelligent voice communication system Details for Ordering Model Part Number Description OP921 S54320-F4-A2 Photoelectric Smoke Detector DB-11 500-094151 Detector Mounting Base DB-11E 500-094151E Detector Base {small} DB2-HR S54320-F12-A1 Relay Base RL-HC 500-033230 Remote Alarm Indicator: 4” octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: single-gang box mount, red FDBZ492 S54319-B22-A1 Addressable Air-Duct Housing FDBZ492-HR S54319-B23-A1 Addressable Air-Duct Detector with Relay LK-11 500-695350 Base Locking Kit STI-9604 ─ ─ STI Mechanical Protection Guard See: www.STI-USA.com for further details on ordering Model STI-9604. In Canada, order: Model Part Number Description DB-11C 500-095687 Detector Mounting Base for ULC (Listed) ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet Cerberus® PRO Fire Safety Products Thermal (Heat) Detector Model HI921 Answers for infrastructure Intelligent Detection Devices 9901 Thermal (Heat) Detector Product Overview The Intelligent Thermal (Heat) Detector (Model HI921) provides an advanced method of detection, address programming and supervision ─ combined with sophisticated FACP communication. Model HI921 uses a state-of-the-art thermistor, microprocessor and advanced signal analysis, providing high reliability and accuracy. Further, Model HI921 is a cost-effective, two-wire / addressable thermal detector that provides a distinctive, advanced feature: field-selectable temperature settings specially tailored for application-specific detection needs. Model HI921 provides seven (7) field-selectable temperature-range settings: 135°F (57°C) ─ 174°F (79°C) with fixed and rate-of-rise programmability. This variance provides the customer with maximum flexibility to program the temperature settings to suit multiple application needs and changing environmental conditions. Additionally, Model HI921 can be configured to provide a low-temperature warning signal at 40°F (4.4°C). This feature − along with a compatible FACP (FireFinder® XLS, or with either Model FC922 or Model FC924) − serves as prevention of water freezing in pipes for sprinkler systems, meeting NFPA 72. Model DPU Model HI921 is compatible with the Siemens field-device programmer / test unit (Model DPU), which is a compact, portable, menu-driven accessory for electronically programming and testing detectors easily and reliably. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods, such as dials or switches, and reduces installation and service costs by electronically programming and testing the detector prior to installation. Each detector consists of a solid state, non-mechanical thermal sensor, and microprocessor-based electronics with a low-profile plastic housing. Model HI921 is Underwriters’ Laboratories ( UL521) Listed as a thermal (heat) detector. • Provides seven (7) field-selectable settings in the 135° − 174°F (57.2° − 78.9°F) temperature range • Tri-color detector-status light-emitting diode (LED) with 360° viewing • Compatible with Model DPU (device programmer / loop tester) • Utilizes advanced microprocessor-based signal processing • Provides a low-temperature warning at 40°F (4.4°C) • Each detector is self-testing:  complete diagnostics performed every 10 seconds • Polarity insensitive utilizing SureWireTM technology • Compatible with Model DB-11−series mounting bases • Field programmable as rate-of-rise or fixed temperature • Compatible with Siemens Model ‘H’-series devices on the same loop (with Model FC9−series fire-alarm control panels) • Superior EMI / RFI immunity • RoHS compliant • UL521 Listed and ULC Listed; FM (#3230, #3210 ), CSFM (#72720067:0258) Approved s Industry, Inc. Building Technologies Division Cerberus® PRO Product Overview ─ (continued) Each Model HI921 detector base also contains a provision for an optional, concealed locking mechanism to prevent unauthorized removal of the detector head (Model LK-11). For proper operation of Model DPU, the technician selects the accessory’s program mode, and enters the desired address. In turn, Model DPU automatically sets and verifies the address, as well as tests the detector. When in the ‘test’ mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Model DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programming and testing equipment from practically any location. Operation Model HI921 also utilizes a modern, accurate and shock-resistant thermistor to sense temperature changes: Each Model HI921 detector provides seven (7) pre-programmed parameter sets that can be selected by the FACP. Detector Supervision and Testing Model HI921, which is listed as a self-testing device, contains a tri- color light emitting diode (LED) indicator, capable of flashing any one (1) of three (3) distinct colors: Green, Yellow, or Red. During each flash interval, the microprocessor-based detector monitors the following: • Temperatures reaching programmed thresholds • Internal sensors and electronics are functional Based on the monitoring results, the LED indicator flashes the following colors based on the following conditions: Flash Color Condition Flash Interval (in seconds) Green*: Normal supervisory operation. Temperature has not reached programmed alarm thresholds or set points. 10 Yellow:Detector is in trouble and needs replacement.4 Red: Alarm condition. 1 No Flash: Detector is not powered. ─ ─ * LED can be turned OFF. Please follow the corresponding description of the panel used. A quick, visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the Model FC9- series FACPs indicating the status and settings assigned to each individual detector. Installation All Model HI921 detectors use a surface-mounting base, Model DB-11 or Model DB-11E, which mounts on a 4-inch octagonal, square or single-gang electrical box. The base utilizes screw- clamp contacts for electrical connections and self-wiping contacts for increased reliability. The Model DB-11 base can be used with the optional Model LK- 11 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has decorative plugs to cover the outer mounting screw holes. Model HI921 may be installed on the same initiating circuit with the Siemens Model ‘H’-series detectors [when used with the Model FC9-series of FACPs] ─ • Model HFP-11 • Model ‘HMS’-series manual stations • Model ‘HTRI’-series interfaces • Model HCP output-control devices • Model ‘HZM’-series of addressable, conventional zone modules Application Data Installation of Model HI921 detectors requires a two-wire circuit. In many retrofit cases, existing wiring may be used. ’T-tapping’ is permitted only for Style 4 (Class B) wiring. Model HI921 is polarity insensitive, which can greatly reduce installation and debugging time. Model HI921 can be applied within the maximum 50-feet center spacing (2,500 sq. ft. areas), per UL. This application guideline is based on ideal conditions, specifically, smooth ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens ─ Fire Safety distributor or sales office whenever you need assistance applying Model HI921 in unusual applications. Be sure to follow NFPA guidelines and UL Listed / ULC Listed installation instructions ─ included with every Siemens − Fire Safety detector ─ and local codes as for all fire-protection equipment. s Industry, Inc. Building Technologies Division Cerberus® PRO Specifications Model HI921 is a plug-in, (2) two-wire thermal (heat) detector, compatible with FireFinder XLS and Model FC9-series FACPs. Each Model HI921 detector has microcomputer-chip technology and highly stable, solid-state electronic circuitry. The Model HI921 detector utilizes a modern, accurate and shock- resistant thermistor to sense temperature changes. This electronic-sensing method virtually eliminates thermal lag associated with mechanical temperature-sensing devices, and provides almost instantaneous temperature status to the FACP. Model HI921 provides seven (7) field-selectable, pre-programmed temperature settings: • Fixed 135°F (57°C) • Fixed 145°F (63°C) • Fixed 155°F (68°C) • Fixed 165°F (74°C) • Fixed 174°F (79°C) • Rate-of-Rise: 15°F / min. (8.3°C) at fixed 135°F (57°C) • Rate-of-Rise: 15°F / min. (8.3°C) at fixed 174°F (79°C) Additionally, the Model HI921 detector has the following optional feature: • Model HI921 provides indication of potential water freezing for sprinkler systems, via configuration for reporting a low-temperature warning of 40°F (4.4°C). This feature is compatible with FireFinder XLS panels, as well as with Models FC922 and FC924. Technical Data Operating Temperature +32°F (0°C) to 100°F (38°C) Range: [with 135°F (57°C) alarm- threshold setting] Relative Humidity: 0-95%; non-condensing Air Pressure: No effect Input Voltage Range: 16VDC − 30VDC Alarm Current (max.): 410μA Standby Current (max.): 250μA, max. (average) Maximum Spacing: 50-foot centers (2,500 sq. ft.), per NFPA 72 and ULC-S524 Thermal Rating: Model HI921 provides up to seven (7) field-selectable, pre- programmed temperature settings:  Fixed 135°F (57°C)  Fixed 145°F (63°C)  Fixed 155°F (68°C)  Fixed 165°F (74°C)  Fixed 174°F (79°C)  Rate-of-Rise: 15°F / min. (8.3°C / min) at fixed 135°F (57°C)  Rate-of-Rise: 15°F / min. (8.3°C / min) at fixed 174°F (79°C) Detector Weight: 0.317 lbs. (0.144 kg.) s Cerberus® PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] April 2014 ─ Supersedes sheet dated 6/2013 (Rev. 3) Mounting Diagram Dimensions Compatibility Chart Model Number Data Sheet Number Description — 6300 FireFinder® XLS (system overview) FC901 9813 50-point panel FC922 9815 252-point system (networkable) FC924 9815 504-point system (networkable) Details for Ordering Model Part Number Description HI921 S54320-F5-A2 Thermal (Heat) Detector DB-11 500-094151 Detector Mounting Base DB-11E 500-094151E Detector Base {small} RL-HC 500-033230 Remote Alarm Indicator: 4” octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: single-gang box mount, red LK-11 500-695350 Base Locking Kit STI-9604 ─ ─ STI Mechanical Protection Guard See: www.STI-USA.com for further details on ordering Model STI-9604. In Canada, order: Model Part Number Description DB-11C 500-095687 Detector Mounting Base ( ULC Listed) ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet Cerberus® PRO Fire Safety Products Multi-Criteria Fire / CO Detector [with ASAtechnologyTM] Model OOHC941 Answers for infrastructure Intelligent Detection Devices 9903 Multi-Criteria Fire / CO Detector [with ASAtechnologyTM] Product Overview Model OOHC941 is an advanced, multi-criteria fire / CO detector that incorporates a redundant, optical / thermal sensor with a carbon monoxide (CO) sensor. Model OOHC941 uses a unique forward / backward light-scattering technology providing state-of-the-art, unparalleled fire detection to the widest range of fire types. Model OOHC941 is programmable as a high- sensitivity detector, and meets the requirements of NFPA 76 Standard (for the Fire Protection of Telecommunications Facilities) as a Very Early Warning Fire Detector (VEWFD). The Model OOHC941 detector is a flexible, multi-purpose detector, providing a complete solution to meet fire and CO life-safety gas-detection needs. The Multi-Criteria Fire / CO Detector can be field programmed for simultaneous and / or independent functionality, depending on the exact customer and application requirements. For instance, the detector can utilize the optical, heat and CO sensors together for enhanced fire detection (multi- criteria), as well as simultaneously provide independent outputs for CO gas life-safety and heat detection. Any combination of the sensors is possible. The detector is extremely versatile and meets the following standards: • UL Listed, ULC-S529 Listed (for smoke detection) / ULC-S530 Listed (for heat detection); FM (#3230, 3210) Approved, and CSFM (#7272-0067:0258) Approved • Advanced multi-criteria fire detector that has optical, thermal and CO sensors • Differentiates between deceptive phenomena and an actual fire (nuisance-alarm avoidance) • Provides enhanced detection via forward-and-backward light-scattering technology • Supervisory feature for temperature and CO-concentration-threshold monitoring • UL Listed and FM Approved as a multi-criteria and ‘VEWFD’ fire detector • Complies with NFPA 76 (Telco standard) as ‘VEWFD’ high-sensitivity detector • Compatible with Siemens Model ‘H’-series devices on the same loop • Low-temperature warning for sprinkler systems, per NFPA 25 • UL 268A Listed for direct air-duct (4,000 FPM) use • Remote sensitivity-measurement capability • Tri-color detector status LED with 360° viewing • Environmental alternative to ionization detectors • Polarity insensitive utilizing SureWireTM technology • Responds to both flaming and smoldering-fire signatures • Compatible with legacy Model DB-11─series mounting bases • Compatible with Model 8720 / DPU (device programmer / loop tester) • Meets UL, NFPA 72 sensitivity self-monitoring requirements • Automatic environment compensation •Up to 26 application profiles • UL 2075 and NFPA 720 CO life-safety compliant • UL 268 / RoHS compliant s Industry, Inc. Building Technologies Division Cerberus® PRO Product Overview ─ (continued) • Multi-criteria fire detector ( UL 268) • Carbon Monoxide (CO) Gas detector ( UL 2075) • Heat detector ( UL 521) with five (5) possible field-selectable temperatures; combined with four (4) rate-of-rise options • Direct in-duct (plenum) detector ( UL 268A) • Supervisory monitoring for CO levels and temperature ranges • NFPA 76 (Telco Standard) as VEWFD • Low-temperature warning signal at 40°F (4.4°C) ─ for sprinkler systems, per NFPA 25 / NFPA 72 Model OOHC941 ─ which provides extremely accurate and reliable fire detection with built-in redundancy ─ utilizes advanced, multi-criteria detection technology known as ASA (Advanced Signal Analysis) that allows the detector to distinguish non-threatening deceptive phenomena. For instance, the signals from the detector’s sensors are monitored and processed via the ASA-patented algorithm technology, which combines the signals into a neural network to create an intelligent, multi-criteria detector. The encompassing result is a detector that provides enhanced detection to a wide range of products of combustion ─ while offering unsurpassed rejection to nuisance-alarm sources, such as: dust, steam, aerosols and other deceptive phenomena that could cause false alarms. Since the multi-criteria, CO detector is a (2) two-wire, addressable device, it is then able to function as a multi- purpose detector ─ satisfying fire, heat and carbon monoxide (CO) gas detection in a singular, aesthetically pleasing package. Further, Model OOHC941 serves as an extremely cost-effective, viable solution that saves product, installation and maintenance costs (compared to other multiple-detector alternatives). Each detector fits into one (1) wall-or-ceiling footprint, and only occupies one (1) address on the signal-line circuit (SLC). A patented forward-and-backward, light-scattering technology ─ which is able to distinguish both small and large products of combustion ─ operates at the core of each Model OOHC941 detector. Additionally, each Model OOHC941 provides an environmental-friendly solution to ionization detectors, eliminating the need for a radioactive source and eventual disposal requirements. Thus, each detector is capable of detecting both smoldering and flaming fire ─ all in ecologically efficient manner ─ and is a valid, RoHS- compliant (Restriction of Hazardous Substances) detection alternative to ionization detectors. Two (2) thermal sensors and an electromechanical CO sensor are also included, making each Model OOHC941 detector a robust, reliable device suitable for the most challenging applications. Model OOHC941 also works as a carbon monoxide (CO) life-safety gas detector, compliant with NFPA 720 and UL 2075. Operation Forward-and-Backward Light-Scattering Technology (with CO sensor) 1. Heat sensors 4. Forward scatterer 2. Receiver 5. Labyrinth 3. Backward scatterer 6. CO sensor The high-quality, optical-electronic measuring chamber for each Model OOHC941 houses the following components:  Two (2) optical transmitters  One (1) optical receiver  Two (2) thermal sensors  One (1) CO sensor The transmitters illuminate the smoke particles from different angles: one sensor acts as forward scatterer, the other sensor as a backward scatterer. The scattered light then hits the receiver (photodiode) and generates a measurable electric signal. The combination of a forward-and-backward scatterer facilitates optimum detection, as well as differentiates between light-and-dark particles / particle size. This type of detection creates standardized, responsive behavior and optimizes the differentiation between wanted signals and deceptive phenomena. In addition, the heat sensors make it possible to detect fires without smoke generation. The CO sensor enables faster detection of fires with incomplete combustion, as well as fires with the development of high levels of CO. The combination of optical, thermal and CO sensor signals optimizes detection reliability. s Industry, Inc. Building Technologies Division Cerberus® PRO Operation ─ (continued) This scenario generates the following advantages:  Early detection of all fire types of fire ─ whether they generate light-or-dark smoke, or no smoke  The fire detector can be operated at a lower sensitivity level, thus achieving a higher immunity against false alarms that may otherwise be caused by cold aerosols (e.g. ─ by smoking, electrical welding, etc.). In the case of an open fire, the smoke sensitivity is heightened by a temperature increase ─ which means that a detection-reliability level that is comparable to a wide-spectrum smoke detector ─ can be achieved and maintained. Field-Device Programmer / Test Unit Model OOHC941 is compatible with the Device Program / Test Unit accessory, which is used to program and verify the address of the detector. The technician selects the accessory’s program mode, and enters the desired address. Model 8720 / DPU automatically sets and verifies the address and tests the detector. Model 8720 / DPU eliminates the need for cumbersome, unreliable mechanical programming methods ─ such as dials or switches ─ and reduces installation and service costs by electronically programming and testing the detector prior to installation. Model 8720 / DPU operates on AC power or rechargeable batteries, providing flexibility and convenience in programmer and testing equipment from practically any location. When in ‘test’ mode, Model 8720 / DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Field-selectable application profiles Model OOHC941 provides 26 user-friendly, field-selectable application profiles, indentified with universally known names (e.g. ─ Hotel, Telco, Office, Parking Garage, Dormitory, and Data Center etc.) Refer to installation manual: P/N ─ A6V10324657 for a complete list and description of application profiles. Due to generic-name classification, no cross-reference tables are required as the application name resides in the panel’s configuration tool. This user-friendly feature ─ along with the algorithms provided by ASAtechnology ─ provides a reliable, field-configurable detector suitable for an array of applications. Field-selectable temperature settings Model OOHC941 provides five (5) field-selectable temperature thresholds, ranging from 135°F to 175°F (57°C to 79°C), with fixed and rate-of-rise options. These ranges provide maximum flexibility to program and easily adjust the temperature settings that suit multiple application needs within a building or changing environmental conditions. Additionally, Model OOHC941 can be configured to provide a low-temperature warning signal at 40°F (4.4°C). Model OOHC941 occupies only one (1) address on the SLC and provides a CO cell end-of-life warning and fault condition meeting NFPA 720 and UL 2075 requirements. Model OOHC941 ─ in combination with FireFinder® XLS, as well as the Models FC922 and FC924 fire-safety systems from Siemens ─ provide an ideal NFPA 720-compliant system with separate-and-distant signaling for the carbon monoxide (CO) life-safety and fire signals. This configuration (along with connection to a compatible fire alarm control panel {FACP}) meets NFPA 72 requirements for sprinkler-temperature monitoring, and serves as prevention of water freezing in pipes for water-based suppression systems. Ambient supervisory feature for temperature and for Carbon Monoxide (CO) Another highlight for Model OOHC941 is supervision of ambient temperatures, allowing the end user to set an unique, specified warning point at a customized temperature threshold ranging from -4°F to 120°F (-20°C to 49 °C). This feature is practical for monitoring of machinery; special processes, or for environments where maintaining a temperature is critical as an early-warning supervisory signal. Optionally, Model OOHC941 also provides supervision of the carbon-monoxide (CO) level selected by the customer. The CO supervision is provided in addition to the normal UL 2075 and NFPA 720 alarm levels, and is customizable by the user for special applications. Configurable range is 30 ─ 600 PPM with a compatible FACP. CO Detection In addition to the multi-criteria functionality, the Model OOHC941 detector provides an independent carbon monoxide (CO) life-safety signal that meets the requirements of NFPA 720 and UL 2075, and meets CO sensitivity limits of UL 2034 standard. The detector operates from a reliable electrochemical CO cell, transmitting CO concentration on an independent signal separate from the fire-detection signals to the FACP. This method is especially useful for any building that uses fossil-burning fuel sources, due to the potential of increased CO intoxication risk. Some application examples include: hotel; heating rooms; car parks; combustion power plants; automotive workshops; chemical labs, or production sites. s Industry, Inc. Building Technologies Division Cerberus® PRO Operation ─ (continued) Self-monitoring for smoke-sensor sensitivity Model OOHC941 provides an automatic self-monitoring sensitivity check that complies with the NFPA 72 sensitivity requirements. When connected with a compatible FACP, it provides automatic and dynamic sensitivity verification within the agency-listed-and-approved limits. Besides checking for sensor integrity and automatic environmental compensation, Model OOHC941 provides a display and report of sensitivity in percent-per-foot (or percent-per-meter) at the FACP. Profile Overview The Multi-Criteria / CO detector contains a tri-color LED indicator, capable of flashing any one (1) of three (3) distinct colors: green, yellow, or red. During each flash interval, the microprocessor-based detector monitors the following: • Smoke in its sensing chamber • Smoke sensitivity is within the range indicated on the nameplate label • Internal sensors and electronics Based on the results of the monitoring, the LED indicator flashes the following: Flash Color Condition Flash Interval (in seconds) Green*: Normal supervisory operation. Smoke sensitivity is within rated limits. 10 Yellow:Detector is in trouble and needs replacement.4 Red: Alarm condition. 1 No Flash: Detector is not powered. ─ ─ * LED can be turned OFF. Please follow the corresponding description of the panel used. A quick, visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the Model FC9-series FACPs, indicating the status and settings assigned to each individual detector. Installation All Model OOHC941 detectors use a surface-mounting base (Model DB-11 or Model DB-11E), which mounts on a 4-inch octagonal, square or single-gang electrical box. The base utilizes screw-clamp contacts for electrical connections and self-wiping contacts for increased reliability. The Model DB-11 base can be used with the optional Model LK-11 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has decorative plugs to cover the outer mounting screw holes. Model OOHC941 may be installed on the same initiating circuit with the Siemens Model ‘H’-series detectors [when used with the Model FC9-series of FACPs] ─ • Models HFP-11, HFPT-11 • Model ‘HMS’-series manual stations • Model ‘HTRI’-series interfaces • Model HCP output-control devices • Model ‘HZM’-series of addressable, conventional zone modules Each detector consists of the following:  Dust-resistant photoelectric chamber  Solid state, non-mechanical thermal sensor  CO sensor  Microprocessor-based electronics with a low-profile plastic housing Each Model OOHC941 fire detector is shipped with a protective dust cover: All Model OOHC941 detectors are approved for operation within the UL-specified temperature range of 32° to 120°F (0° to 49°C) ─ depending on heat-detector configuration (see to installation manual: P/N A6V10324657) for details. Application Data Installation of Model OOHC941 detectors requires a two- wire circuit. In many retrofit cases, existing wiring may be used. ’T-tapping’ is permitted only for Style 4 (Class B) wiring. Model OOHC941 is polarity insensitive, which can greatly reduce installation and debugging time. Model OOHC941 fire detectors can be applied within the maximum 30-feet center spacing (900 sq. ft. areas,) as referenced in NFPA 72. This application guideline is based on ideal conditions ─ specifically, smooth ceiling surfaces; minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to ventilation or heating and air conditioning outlets. Exposed joints or beamed ceilings may also affect safe spacing limitations for detectors. s Industry, Inc. Building Technologies Division Cerberus® PRO Operation ─ (continued) Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens Industry ─ Fire Safety distributor or sales office whenever you need assistance applying Model OOHC941 in unusual applications. Be sure to follow NFPA guidelines and UL Listed / ULC Listed installation instructions ─ included with every Siemens − Fire Safety detector ─ and local codes as for all fire protection equipment. Technical Data Operating Temperatures: +32°F (0°C) to 120°F (49°C) depending upon heat-detector configurations (see to installation manual: P/N A6V10324657) for details Heat-Detector Range: +135°F (57°C) to 175°F (79°C) Thermal Rating: Model OOHC941’s Field-Selectable Temperature Profiles Fixed Temperature, 135°F Fixed Temperature, 145°F Fixed Temperature, 155°F Fixed Temperature, 165°F Fixed Temperature, 175°F Fixed Temperature, 135°F + Rate-of-Rise (R-o-R) 15°F Fixed Temperature, 175°F + Rate-of-Rise (R-o-R) 15°F Fixed Temperature, 135°F + Rate-of-Rise (R-o-R) 20°F Fixed Temperature, 175°F + Rate-of-Rise (R-o-R) 20°F Field-Selectable, Alarm-Threshold Setting Profiles 2.5 % / ft. threshold 3.0 % / ft. threshold 2.5 % / ft. threshold (verified) 3.0 % / ft. threshold (verified) Detector Sensitivity Range: UL: 0.77% to 3.82% / ft. NFPA 76 (Telco) VEWFD: 0.2% / ft. Pre-alarm, 1.0% / ft. Alarm Application Profiles: 26 (field configurable) Technical Data ─ (continued) Programmable Supervisory Temperature Warning available with compatible FACPs: -4°F (-20°C) to 120°F (49°C) Programmable Supervisory CO-gas Warning available with compatible FACPs: 30 − 600ppm CO Concentration Response Times: 70 ±5 PPM in 60 − 240 minutes 150 ±5 PPM in 10 − 50 minutes 400 ±10 PPM in 4 − 15 minutes Note: Meets UL 2075 Standard and has been tested to the sensitivity limits defined in UL 2034 Standard. Additionally complies with NFPA 720 code. Relative Humidity: 0-95%; non-condensing Air Velocity ─ (Open Area): 0 − 4,000 feet-per-minute (fpm) Direct-in-Duct: 0 − 4,000 (fpm) Air Pressure: No effect Maximum Spacing : 30-foot centers (900 sq. ft.), per NFPA 72 and ULC-S524 Listed Input Voltage Range: 13VDC − 32VDC Alarm Current: 650μA, max. Quiescent (Standby) Current: 320μA − 400μA Detector Weight: 0.281 lbs. (0.128 kg.) Approvals / Standards: FM 3210, 3220 CSFM 7272-0067:0260 UL 268 NFPA 25 UL 268A NFPA 72 UL 521 NFPA 76 UL 2075 NFPA 720 ─ meets CO sensitivity limits of UL 2034 standard ULC-S524 Listed Mechanical Protection Guard: UL Listed / ULC Listed with STI Guard Model STI-9604 s Cerberus® PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] March 2014 ─ Supersedes sheet dated 5/2013 (Rev. 3) Mounting Diagrams Dimensions Model OOHC941 Model OOHC941 with Model DB-11 base Model OOHC941 with Model DB-11E base FACP Compatibility Table Model Data Sheet Number Description ― 6300 FireFinder XLS (System Overview) FC901 9813 50-point addressable panel FC922 9815 252-point system (networkable) FC924 9815 504-point system (networkable) Details for Ordering Model Number Part Number Description OOHC941 S54320-F8-A2 Multi-Criteria Fire / CO Detector with ASAtechnology DB-11 500-094151 Detector Mounting Base DB-11E 500-094151E Detector Base {small} DB2-HR S54320-F12-A1 Relay Base RL-HC 500-033230 Remote Alarm Indicator: 4” octagon-box mount, red RL-HW 500-033310 Remote Alarm Indicator: single-gang box mount, red FDBZ492 S54319-B22-A1 Addressable Air-Duct Housing FDBZ492-HR S54319-B23-A1 Addressable Air-Duct Detector with Relay LK-11 500-695350 Base Locking Kit STI-9604 — STI Mechanical Protection Guard See: www.STI-USA.com for ordering Model STI-9604 System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit mod- els are offered, each available for low- and high-temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activa- tion. The ROR element of the fixed/ROR models is restorable, to accommodate field-testing the unit. Installation flexibility. To satisfy a variety of installations, the 5600 series easily mounts to single-gang and octagonal back boxes. These models also accommodate four-square back boxes, when used with a square to round plaster ring. The mounting bracket is reversible to allow for flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in degrees Fahrenheit and Celsius. Fixed temperature models are identified “FX”, while combination fixed/rate-of-rise units are marked “FX/ROR”. The 5600 series also provides a post-activation indicator in the form of a collector. Once the detector has been activated, the collector drops from the unit, to easily identify the specific unit in alarm. Models Available Single-circuit Models 5601 135°F Fixed Temperature / Rate-of-Rise 5602 194°F Fixed Temperature / Rate-of-Rise 5603 135°F Fixed Temperature 5604 194°F Fixed Temperature Dual-circuit Models 5621 135°F Fixed Temperature / Rate-of-Rise 5622 194°F Fixed Temperature / Rate-of-Rise 5623 135°F Fixed Temperature 5624 194°F Fixed Temperature Product Overview Multiple configurations available to satisfy a broad range of installations: • Single- and dual-circuit models • Fixed temp and combination fixed- temp/rate-of-rise • 135ºF or 194ºF ratings. Simple to read alphanumeric text on the exterior of the detector indicates activation method and temperture rating Easy to use terminal screws that provide a more positive wiring connection A broader range of back box mounting options: • Single gang • 3.5″ and 4″ Octagonal • 4″ square with square to round plaster ring Reversible mounting bracket for flush and surface mount installations 5601 S2101 5600 Series Mechanical Heat Detectors C O N V E N T I O N A L D E T E C T I O N APPROVED 3016008 199-03-E 7270-1209:227 Engineering Specification Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed tem- perature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mount- ing bracket for mounting to 31⁄2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise ele- ment of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Model Circuit Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601 Single 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. Ordering Information Physical Specifications Maximum Installation Temperature 5601, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Input Terminals 14–22 AWG Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601, 5602, 5621, and 5622 only) Mounting 31⁄2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6 – 125 VAC / 3A 6 – 28 VDC / 1A 125 VDC / 0.3A 250 VDC / 0.1A © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0351-000•2/04•#994 System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx: 44.1403.891921 System Sensor in China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor – India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor – Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 HMS Series Intelligent Initiating Devices 6306 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety & Security Products HMS-Series Intelligent Initiating Devices Models HMS-D, HMS-S Product Overview Models HMS-S and HMS-D intelligent manual fire- alarm boxes provide the most advanced method of address programming and supervision. Each Model HMS-series manual fire-alarm box achieves the state of an ‘intelligent-initiating device’ by incorporating custom microcomputer-chip technology with sophisticated, bi-directional communication capabilities with the FACP. Specifications Models HMS-S and HMS-D are constructed of durable, molded polycarbonate material that is matte finished in red with raised white lettering. The housing accommodates a ‘pull-down’ lever, which ─ when operated ─ locks into position; indicating the manual fire-alarm box has been activated. The pull down lever remains down / in the ‘locked’ position, until the fire-alarm box is manually reset. The manual fire alarm box can only be reset by opening the hinged housing cover with an Allen key; followed by closing and locking the cover. Models HMS-S and HMS-D operate with Siemens ─ Fire Safety FACPs. The microcomputer chip to the manual fire-alarm box has the capacity of storing ─ in memory ─ identification information as well as important operating-status data. Innovative technology from Siemens ─ Fire Safety also allows all Model HMS-series intelligent manual fire-alarm boxes to be programmed via the Device Programmer / Test Unit (Model DPU). Model DPU is a compact, portable and menu-driven accessory that makes programming and testing of a manual fire- alarm box device faster, easier and more dependable than previous methods. The programmer / tester eliminates the need for mechanical-addressing mechanisms of a device because Model DPU electronically sets the address of the manual fire-alarm box into its microcomputer chip, non-volatile memory. Hence, vibration, corrosion and other conditions that can compromise or even deteriorate mechanical-addressing mechanisms are no longer a cause for concern. • Durable design • Shock-and-vibration resistant • Pull-down lever is down, until manually reset ƒ Reset with Allen Key ƒ No break rods necessary • Custom microcomputer-chip technology • Dynamic supervision to the fire-alarm control panel (FACP) • Polarity insensitive via SureWireTM technology • Two-wire operation • Surface or semi-flush installation • Model DPU programs and verifies address and tests functionality of each device ƒ Electronic-address programming is easier, more efficient and more dependable • Comes in single-action (Model HMS-S) and double-action (Model HMS-D) stations • UL Listed and ULC Listed; FM, CSFM & NYC Fire Dept. Approved Model HMS-D Dual-Action Station Model HMS-S Single-Action Station ARCHITECT AND ENGINEER SPECIFICATIONS s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS (SII) Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 December 2011 Supersedes sheet dated 6/10 (Rev.2) Specifications ─ (continued) Models HMS-S and HMS-D are fitted with screw terminals for connection to an addressable circuit, and can be either surface or semi-flush mounted. The Model HMS-series manual fire-alarm boxes derive their power, communicate information and receive commands over a single pair of wires. The Model HMS-series is compatible on the same circuit with all ‘H’-series detectors, interfaces or addressable, conventional zone modules. Details for Ordering Electrical Ratings Current Draw (Active or Standby) ─ 1.5mA Mounting Diagram Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. Answers for infrastructure ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet Models FDBZ492, FDBZ492-HR, FDBZ492-R and FDBZ492-PR {with FDBZ-WT and FDBZ-RTL} Specialized Devices Air-Duct Housings (FDBZ Series) Product Overview The Siemens ─ Fire Safety Model ‘FDBZ’-series of air- duct-detector housings are designed for use with the Siemens Model ‘H’-series; as well as with Models OOH941, OOHC941, OP121; OP921; 8710; 8713, and PE-11 detectors. Designed for installation directly to heating, ventilating and air-conditioning (HVAC) duct systems, the Model ‘FDBZ’-series of duct housings complies with National Fire Protection Association Standard (NFPA) No.’s 72 and 90A, and is Underwriters’ Laboratories Listed. When equipped, the air-duct detector housing will signal the presence of smoke being carried through the duct system. Air-duct detectors are not intended to be substituted for open-area detection. Notes: Most conventional time-control equipment guarantee only one (1) detector per zone when the detector’s operated relay function is critical. The connection of a remote lamp and a remote relay −per detector − is allowed. Refer to the installation manual for the respective conventional fire system. Notes - (cont.’d): With either the Cerberus™ PRO series or FireFinder™ XLS series of FACPs, up to 252-addressable detectors with relays per circuit may be used. The connection of an intelligent remote lamp (ILED) and a remote relay is allowed for each detector simultaneously. Specifications The Model ‘FDBZ’-series of air-duct housings are uniquely designed to use with the photoelectric detector. Sensitivity of Models PE-11 and OP121 detectors can be verified for calibration via LED visual status or a Model RSAW-11, Model RSAC-11 or FDBZ-RTL multi-color remote lamp. A green flash indicates the detector has passed its self test. Amber indicates a Trouble condition, and red indicates an Alarm event. Sensitivity for Models HFP-11, FP-11, HFPO-11, OP921, OOH941 and OOHC941can be verified from the multi- color LED of the respective detector, or its sensitivity reading may be printed by command from the corresponding FACP to an optional printer. 9906 Model ‘FDBZ’ Series of Air-Duct Housings and Detectors CerberusTM PRO Fire Safety & Security Products • Four (4) models available ƒ Addressable and conventional with and without relays • Compatible with various Siemens ─ Fire Safety fire-alarm control panels (FACPs) • Magnet test feature with the Model OP121 conventional detector • Design for air-velocity range of 100 to 4,000 feet-per-minute (fpm) • Robust, compatible conventional remote indicator test switch that incorporates tri-color light-emitting diode (LED) • Clear housing cover with smoke test port on cover for quick identification of detector type ƒ Removable with only four (4) captive-thumb screws (no tools required) ƒ Includes a smoke / aerosol detector test port • Optional NEMA 4X-reinforced, stainless-steel and watertight enclosure available, Model FDBZ-WT • No tools required for cover removal, sampling and exhaust-tube installations • Trouble-event activation upon front-cover removal • Alarm LED visible from front Remote alarm indicator [FDBZ-RTL] FDBZ-series of air-duct housings [FDBZ492, FDBZ492-HR, FDBZ492-R and FDBZ492-PR] Watertight housing [FDBZ-WT] • Self-contained model available with ‘on-board’ power supply for conventional detectors • Expanded temperature range • Relay models available • UL268A Listed, ULC-S529 Listed s Industry, Inc. Building Technologies Division CerberusTM PRO Specifications ─ (continued) The remote alarm indicator (Model FDBZ-RTL) allows for manual testing via a key-switch for the conventional detector as well as the conventional air-duct housing with relay. Model FDBZ-RTL, which mounts remotely from the conventional air-duct housing, allows for manual relay- output control. The duct-detector remote indicator key- switch also indicates the current state of the detector. The watertight housing (Model FDBZ-WT), which allows the air-duct detector housing to be installed inside the separate NEMA 4X enclosure, is for installations for either an outdoor area or in environments where excessive moisture is prevalent. Each detector unit employs a cross-sectional sampling principle of operation. Inlet sampling tubes are available in four (4) lengths (see: Sampling Tube Selection Table). Outlet sampling tubes are one (1) common length and draw. A continuous, cross-sectional sample of air moves through the duct. Stratification or skin affect phenomenon that occurs in the duct can prevent smoke (especially in large ducts) from reaching a spot-type detector. In addition, the unique design of the sampling chamber insures uniform sensitivity in air velocities, ranging from a low of 100 fpm to as high as 4,000 fpm. Each air-duct housing comes with three (3) wiring entry ports: ƒ Two (2) 3/4” conduit knockouts ƒ One (1) 1/2” conduit opening The inlet sampling tube length is determined by the width of the air duct being protected. The inlet tube ─ greater than and nearest to the duct width ─ should be used (see: Sampling Tube Selection Table). The inlet tube can then be trimmed at the job site to the exact width of the duct. The outlet sampling tube for all ducts ─ irrespective of width ─ has a fixed length of approximately 5.5 inches (14cm.), and is supplied with the air-duct housing. Note: When the use of a remote relay is required, order Model FDBZ492-R for conventional systems; Model FDBZ492-HR for addressable systems. When required, a separate watertight enclosure (Model FDBZ-WT), which is designed to contain the air-duct housings is available. (For full details, refer to installation instructions for the respective air-duct housing.) Note: When a self-contained duct detector with power supply is required, order Model FDBZ492-PR. (For full details, refer to installation instructions part number A6V10330327.) Sampling Tube Selection Table Duct Width Sampling Tube (Model No.) For duct widths 6” to 1’ ST-10 For duct widths 1’ to 3’ ST-25 For duct widths 3’ to 5’ (requires support)ST-50 For duct widths 5’ to 10’ (requires support)ST-100 Maintenance of the detector is easily accomplished via the removal of the duct-housing sampling chamber cover. The detector, which plugs into the housing, is easily removed for cleaning or replacing by a trained technician. All that is necessary for installation of the air-duct detector is the cutting of three (3) small holes for the Sampling Tube installation (template included), and the drilling of two (2) holes for mounting the air-duct housing. The unit is then easily mounted in place, and connection made to the existing wires or terminals ─ if optional accessories are utilized. No mechanical tools are required for removing the cover or connecting the sampling and exhaust tubes to an air-duct housing. Models ST-50 and ST-100 require support. However, Model ST-100 is shipped in two (2) 5-ft. (152 cm.) pieces with a coupling for field assembly. Technical Data Operating Temperature +32°F (0°C) to 120°F (49°C) Ranges: Sampling Tube Pressure > 0.01 inches; Range of Differences: < 1.2 inches of water column Relative Humidity: 0 ─ 95%; non-condensing Air Pressure / No effect / Altitude Range: No limitations Air-Duct Velocity: 100 ─ 4,000 ft. / min (0.51─ 20m / sec) Dimensions: {H -x- W -x- D} ƒ Rectangular: 14.38” -x- 5” -x- 2.5” (37 cm. -x- 12.7 cm. -x- 6.36 cm.) ƒ Square: 7.75” -x- 9” -x- 2.5” (19.7 cm. -x- 22.9 cm. -x- 6.36 cm.) Detector Weight: 1.8 Lbs. (0.82 Kg.) s Industry, Inc. Building Technologies Division CerberusTM PRO Operation Based on the monitoring results, the LED indicator flashes the following colors based on the following conditions: Flash Color Condition Flash Interval (in seconds) Green*: Normal supervisory operation. Smoke sensitivity is within rated limits. 10 Yellow: Detector is in Trouble condition, and needs either repair or replacement. 4 Red: Alarm condition. 1 No Flash: Detector is not powered. ─ ─ * LED can be turned OFF. Please follow the corresponding description of the panel used. Compatible FACPs Model Number Data Sheet Number Description FC901 9813 50-point panel FC922 9815 252-point addressable system FC924 9815 504-point addressable system Products included with the air-duct housing: - (1) short-return (outlet) tube - (1) stopper - (2) #12 + 3/4” sheet-metal screws - (1) mounting template Note: Detector and sampling tube to be purchased separately. Minimum hardware required is: one (1) air-duct housing assembly; one (1) sampling tube and one (1) detector. Details for Ordering Model Number Part Number Description A two-wire addressable or conventional duct detector (without relays) designed for direct use on heating, ventilating and air- conditioning (HVAC) air-duct systems. When equipped, the air-duct detector housing will signal the presence of smoke being carried through the duct system. For use with the following Models: FDBZ492 S54319-B22-A1 − 8710 − 8713 − 8854 − HFPO-11 − FP-11 − HFP-11 − OOH941 − OP121 − OOHC941 − PE-11 A two-wire addressable duct detector (with relays) designed for direct use to HVAC air- duct systems and works with the Remote Test Switch (FDBZ-RTL). This part has a programmable relay base, and when equipped, the addressable air-duct detector housing will signal the presence of smoke being carried through the duct system. For use with the following Models: FDBZ492-HR S54319-B23-A1 − 8710 − 8713 − OOH941 − OOHC941 − FP-11 − HFP-11 − HFPO-11 − OP921 FDBZ492-R S54319-B24-A1 A two-wire conventional duct detector with relays designed for direct use on HVAC air- duct systems. This detector has a relay base, and when equipped with conventional air-duct housing, will signal the presence of smoke being carried through the duct system. For use with the following Models: − PE-11 − OP121 − 8854 FDBZ492-PR S54319-B25-A1 A four-wire conventional duct detector with relays and a built-in power supply. Housing is designed for direct use to HVAC air-duct systems. It has a relay base with a built-in power source. When equipped with conventional air-duct housing, this duct detector will signal the presence of smoke being carried through the duct system. For use with the following Models: − PE-11 − FDBZ492-R − FDBZ492-HR FDBZ-RTL S54319-S27-A1 Device is used for manual testing via a key- switch for duct-housing Models FDBZ492-R, FDBZ492-PR and FDBZ492-HR. Device mounts remotely from the conventional air- duct housing, allowing for manual relay- output control. The duct-detector remote key-switch also indicates the current state of the detector. For use with the following Models: − FDBZ492-HR − FDBZ492-R − FDBZ492-PR An optional, separate watertight NEMA 4X enclosure (Model FDBZ-WT) that provides added watertight protection for any of the Model FDBZ492-series duct housings. The duct housing fits into the separate 4X enclosure. This part allows the air-duct detector housing to be installed in the separate enclosure, and can be used in either an outdoor area or in environments where excessive moisture is prevalent. For use with the following Models: FDBZ-WT S54319-B26-A1 − FDBZ492 − FDBZ492-HR − FDBZ492-R − FDBZ492-PR ST-10 500-649710 Sampling tube for Ducts 6” to 1’ ST-25 500-649711 Sampling tube for Ducts over 1’ to 3’ ST-50 500-649712 Sampling tube for Ducts 3” to 5’ ST-100 500-649713 Sampling tube for Ducts 5’ to 10’ s CerberusTM PRO Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Information contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] August 2012 ─ Supersedes sheet dated 3/2012 (Rev. 1) Intelligent Device Interface Module 6308 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety &Security Products Intelligent Initiating Devices Intelligent Device Interface Module Model HTRI-M {HTRI-MC for Canada} ARCHITECT AND ENGINEER SPECIFICATIONS • Interfaces and supervises normally open (N.O.) contacts: [i.e. − fire detection] or normally closed (N.C.) contacts: [i.e. − security detection] • Compact size allows mounting in single-gang box behind equipment • Polarity insensitive with SureWire™ technology ƒ Innovative technology supports comprehensive system and interface communication • Dynamic Supervision • (2) Two-wire operation • Device Programmer / Test Unit programs and verifies address and test functionality • UL Listed, ULC Listed; FM, CSFM and NYC Fire Department Approved Product Overview The Intelligent Interface module (Model HTRI-M) is designed to provide the means of interfacing direct shorting devices to the Device Program / Test Unit (Model DPU) for various Siemens ─ Fire Safety fire-alarm control panels (FACPs). Model HTRI-M provides the most advanced method of address programming and supervision ─ including sophisticated FACP-communication ─ in the fire and life safety market. Each Model HTRI-M interface module incorporates microcomputer-chip technology, and advanced bi-directional communication capabilities with the respective FACP. Model HTRI-M is designed to monitor a N.O. or N.C. dry contact, and reports the contact status to the FACP. The microcomputer chip for Model HTRI-M has the capacity of storing ─ in memory ─ identification information, as well as integral operating-status data. Specifications Each Model HTRI-M interface module is programmed, via Model DPU, which is a compact, portable and menu-driven accessory that makes programming and testing a given interface more accurately and efficiently than ever before. Model DPU eliminates the need for mechanical- addressing mechanisms ─ such as program jumpers, DIP switches or rotary dials ─ since Model DPU sets the interface address of Model HTRI-M into its microcomputer-chip, non-volatile memory electronically. Vibration, corrosion and other conditions that deteriorate mechanical-addressing mechanisms are no longer a cause for concern. Model HTRI-M is connected to Model DPU with the programming cable provided with the tester. This programming cable (P/N 110-694927) utilizes two (2) alligator clip connectors, to attach to the HTRI-M. s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS SII‐FS Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 December 2011 Supersedes sheet dated 8/10 (Rev.2) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. Specifications ─ (continued) Model HTRI-M has five (5) leads [one (1) of the five (5) leads is for grounding], which are wired to the system with user-supplied wire nuts. Model HTRI-M is fully compatible on the same Model DLC circuit with all intelligent Siemens model ‘H’-series detectors; ‘HMS’-series addressable, manual stations; or any other ‘H’- series addressable intelligent modules (i.e. ─ Model HZM or Model HCP). Electrical Rating Current Draw (Active or Standby):1.5mA Details for Ordering Model Number Part Number Description HTRI-M 500-034000 Single-input Intelligent Interface Module HTRI-MC 500-034000C Single-input Intelligent Interface Module, [exclusively for Canada] Note: Each HTRI-series model is 3.5 ounces (0.1 kilograms) for Shipping Weight. HTRI Series Interface Modules 6304 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety & Security Products HTRI-Series Interface Modules Models HTRI-D, HTRI-R and HTRI-S Product Overview The Siemens ─ Fire Safety HTRI-series Intelligent interface modules are designed to provide the means of interfacing direct shorting devices to the fire-alarm control panel (FACP) loop circuit. The HTRI-series modules provide the most advanced method of address programming and supervision on the market ─ combined with sophisticated control panel communication. Each HTRI-series interface module incorporates a microcomputer chip, and each interface module achieves the state of an ‘intelligent device’ through its microcomputer chip technology, combined with its sophisticated, bi-directional communication capabilities with the FACP. Specifications The HTRI-series intelligent interface modules are available in three (3) models. Models HTRI-S and HTRI-R are designed to monitor a (N.O) or (N.C) dry contact. The interface module reports the status of the (N.O) or (N.C) contact to the control panel. Model HTRI-S can only monitor and report the status of the contact, while Model HTRI-R incorporates an addressable ‘Form C’ relay. The Model HTRI-R relay and contact device input are controlled at the same address. For the FACP, the relay and input contact can be controlled as a separate function. The relay is typically used where control or shunting of external equipment is required. The Model HTRI-D is a dual-input module that is designed to supervise and monitor two (2) sets of dry contacts. Model HTRI-D only requires one (1) address, but responds independently to each input. Model HTRI-D is ideal for monitoring a water-flow switch and its respective valve tamper switch. Model HTRI has a multi-color LED that flashes green when operating in Normal; ‘amber’ if unit is in Trouble condition, and ‘red’ to indicate a change of state. • Interfacing and supervising normally open (N.O) or normally closed (N.C) contacts • Integral single-pole, double-throw (SPDT) relay on Model HTRI-R (up to 4 amps) • Dual input on Model HTRI-D, using a single address • Polarity insensitive with SureWireTM technology • Multi-color light-emitting diode (LED) indicates system status: ƒ green / amber / red • Easy front access to programming port and wiring terminals • Mounts in a 4-inch square, 2-¼”-deep box (or double-gang box) • Dynamic supervision • Comes with 5-x-5” faceplate • Two-wire operation • Device Programmer / Tester programs and verifies address of the device and tests for proper functionality • Electronic address programming is easy and dependable • UL Listed & ULC Listed; FM, CSFM and NYC Fire Department Approved ARCHITECT AND ENGINEER SPECIFICATIONS s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS (SII) Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 December 2011 Supersedes sheet dated 6/10 (Rev. 2) Specifications (continued) Model HTRI-D flashes twice ─ once for each address, and Model HTRI-R LED indicates a change of state in the relay. The device’s microcomputer chip has the capacity of storing, in memory, identification information; as well as important operating-status information. Siemens ─ Fire Safety innovative technology allows all HTRI-series intelligent interface modules to be programmed via the Device Programming / Test Unit: a compact, portable and menu-driven accessory that makes programming and testing an interface device faster, easier and more dependable than previous methods. The programmer / tester eliminates the need for mechanical addressing mechanisms, such as: program jumpers, DIP switches or rotary dials, since Model DPU electronically sets the HTRI- series interface address into the non-volatile memory of the interface microcomputer-chip. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. The HTRI-series is fitted with screw terminals for connection to an addressable circuit, and is fully compatible on the same Siemens FACPs with all intelligent ‘H’-series detectors, ‘HMS’-series addressable manual stations, or any other addressable intelligent modules, such as Model HZM or Model HCP. All HTRI-series intelligent interface modules are UL Listed. Environmental operating conditions for all HTRI-series modules are 32ºF (ºC) to 120ºF (49ºC) with a relative humidity of no greater than 93%, non-condensing. Electrical Ratings Current Draw (Active or Standby) 1mA Model HTRI-R Relay Ratings Resistive: 4 Amps, 125 VAC 4 Amps, 30 VDC Inductive: 3.5A, 120 VAC (0.6P.F.) 3.0A, 30 VDC (0.6P.F.) 2.0A, 120 VAC (0.4P.F.) 2.0A, 120 VAC (0.35P.F.) 2.0A, 30 VDC (0.35P.F.) Mounting Diagram Models HTRI-S, HTRI-D and HTRI-R mount directly into a 4-inch square, 2 ¼-deep box or to a user-supplied double-gang box. A 5-inch square, off-white faceplate is included with each HTRI-series module. Details for Ordering Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. Agency Listings CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest™ Technology The System Sensor CO1224T and CO1224TR (round) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • RealTest™ enables a functional test using canned CO • Full compliance with UL 2075 • A code-required trouble relay • Wiring supervision with SEMS terminals • A six-year end-of-life timer • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T With RealTest™ technology, the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009. Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) When dangerous amounts of CO are detected, the CO1224T and CO1224TR detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224T and CO1224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code-required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2011 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0437-001 • 4/11 • #2444 Ordering Information Part No. Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224TR 12/24 volt, 4-wire system-monitored round carbon monoxide detector with RealTest™ Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary CO1224T and CO1224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T or CO1224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size: CO1224T Length: 5.1 in, Width: 3.3 in, Height: 1.3 in CO1224TR Diameter: 6 in, Height: 1.3 in Approximate Weight CO1224T: 7 oz ; CO1224TR: 11 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about six years. The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. 1. 2. 3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. CO-PLATE Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Answers for infrastructure ARCHITECT AND ENGINEER SPECIFICATIONS Data Sheet Model ABHW-4S Detection Bases Intelligent Audible (Sounder) Base [designed for sleeping areas] 9910 Intelligent Audible Base (for Sleeping Areas) Cerberus® PRO Fire Safety Products Product Overview The Model ABHW-4S Audible Base from Siemens Industry Inc. is an intelligent, supervised detector base designed for use in sleeping areas of a building. Each Model ABHW-4S base generates a 520 Hz square-wave audio signal, complying with NFPA 72 Standard, as well as UL / ULC Listed applications. Model ABHW-4S provides six (6) field-configurable tone patterns: two (2) volume levels are used with compatible Siemens detectors and FACPs. Steady; Temporal 3 pattern; Temporal 4 pattern; Temporal 4 with low-power; March Time 120, and Canadian March Time 30 are supported by each intelligent audible base for sleeping areas. Model ABHW-4S is fully compatible with all Siemens addressable detectors listed in the detector tables included in this document. (Refer to the Details for Ordering section on Page 2). When used in conjunction with other listed, compatible Siemens fire-safety components, Model ABHW-4S may be used in lieu of single / multiple station smoke alarms to achieve enhanced, system-level functionality. Model ABHW-4S meets the requirements specified in UL268, ULC-S525, ULC-S529 and also UL464, UL2075 including 520Hz, low-frequency requirements for ‘Sleeping Area’. Specifications Model ABHW-4S consists of a standard Siemens — Fire Safety Series ‘11’ detector-base layout — combined with supportive circuitry for Cerberus PRO FACPs and Model ‘HFP’ / ‘SFP’-series detectors. Additionally, each Model ABHW-4S base houses a pre-wired, audible sounder device, capable of generating a 520 Hz square-wave tone that produces a signal up to 85dBA at 10 ft. (3.1m) for localized annunciation. Several power options are available for the Model ABHW-4S audible base, and can therefore be powered in an ordinary four-wire configuration, via use of any one (1) of the following: notification-appliance circuit (NAC); a Siemens PAD-series NAC extender; Model ZIC-4A, or any UL Listed, 24VDC regulated power supply. Note: See the Model ABHW-4S Installation and Operation Manual (IOM: A6V10405588) for further information. All Model ABHW-4S bases are capable of sounding simultaneously, individually or in any combination ─ depending on the detector type, and when it is used and configured with a compatible Siemens FACP. Note: When Model ABHW-4S bases are used with Model ‘H’ / ‘S’-series devices, functionality is limited, and is similar to the Model ADBH-11 audible base. Model ABHW-4S (Front View) Model ABHW-4S (Back View) • Bases for sleeping areas compatible with:  Cerberus PRO fire alarm control panels (FACPs)  FireFinder  XLS FACPs  Siemens PAD-series NAC Extenders • UL268, UL464 & UL2075 Listed; ULC-S525, ULC-S529 Listed; FM ( # 3150, # 3230 & #3010) and CSFM ( #7300-0067:0271) Approved • Meets NFPA 72 code requirements for ‘low-frequency, 520 Hz square-wave tones in sleeping areas’ • Meets NFPA 720 carbon-monoxide (CO) requirement for ‘Temporal 4 tone with 520 Hz in sleeping areas’ • Minimizes footprint on the wall or ceiling  One (1) box solution • Provides highly flexible programming and configuration options with independently controlled outputs by device • Supports six (6) field-configurable audible -tone patterns:  Steady  American National Standards Institute (ANSI) Temporal 3  ANSI Temporal 4 Carbon Monoxide [CO])  Temporal 4 Low Power  March time 120 (and Canadian March time 30) − can also follow the Siemens fire alarm control panel (FACP) notification appliance circuit (NAC) output • Compatible with Cerberus PRO intelligent detectors and Siemens ‘H’ / ‘S’-series devices s Cerberus® PRO NOTICE ─ The information contained in this data-sheet document is intended only as a summary, and is subject to change without notice. The devices described here have specific instruction sheets that cover various technical, limitation and liability information. Copies of these instruction sheets and the General Product Warning and Limitations document, which also contains important information, are provided with the product and, are available from the Manufacturer. Data contained in these documents should be consulted before specifying or using the product. For further information or assistance concerning particular problems contact the Manufacturer. Siemens Industry, Inc. ─ Building Technologies Div. 8 Fernwood Road • Florham Park, NJ 07932 Tel: (973) 593-2600 • Fax: (908) 547-6877 Web: www.USA.Siemens.com/Cerberus-PRO Building Technologies Division SII ─ Fire Safety [Printed in U.S.A ] March 2016 ─ Supersedes sheet dated 3/2015 (Rev. 4) Specifications  (continued) Model ABHW-4S is a UL / ULC Listed supplementary smoke- detection device that meets or exceeds the 85dB at 10 ft. (3.1m) audibility requirement specified in UL268, ULC-S525, ULC- S529 — as well as UL464 / UL2075, including low-frequency requirement of 520Hz for ‘Sleeping Areas’. Compatibility with s FACPs Model ABHW-4S functions with the following: FACP System Type FireFinder ® XLS Person Machine Interface (PMI) v10.02 (or later) Zeus Custom-Configuration Software v10.02 (or later) Device Loop Card (Model DLC) v6.01 (or later) Model FC901 Cerberus PRO 50-point addressable FACP v01.04.20 (24), Software-tool v01.02.16 (53) Models FC922 / FC924 Software-tool v6.0.0R1 (or later) Application Data The smoke detectors used with Model ABHW-4S are subject to the maximum 30 ft. center spacing (900 sq. ft.) as referred to in the National Fire Protection Association Standard 72. This spacing, however, is based on ideal conditions ─ namely: smooth ceiling; no air movement, and no physical obstructions between the fire source and the detector. The aforementioned center-spacing format should be referred to as a guide for detector-installation layout. Do not mount detectors in areas close to ventilating or air-conditioning outlets. Exposed joists or beamed ceilings may also effect safe spacing limitations for detectors. It is mandatory for NFPA 72 guidelines and good engineering judgment be applied to device placements, spacing. Technical Data Connections Admissible Cross- Section Cable: 12 ─ 18 AWG (American Wire Gauge) Design:Two (2) back-end blocks of up to four (4) screw terminals on each side Physical Properties Operating Temperature: 32 ─ 120°F (0° ─ 49°C) Operating Humidity: 10 ─ 95%, non-condensing Sound Output:High: ≥ 85 dB Low: ≥ 75 dB Tones: Steady; Temporal 3; Temporal 4; Temporal 4 low power; March time 120; Canadian March time 30 Mounting Box: 4-inch (10.2 cm.) square gang box Note: A 4” (10.2 cm.) octagon box is not compatible with Model ABHW-4S. Technical Data  (continued) Electrical Ratings Operating Voltage:Loop power: 16 ─ 33 VDC External power: 16 ─ 33 VDC Supervisory Current (max) From SLC loop: 250 µA From external source: 1.0 mA Alarm Current (max) External Power: High dBA: 65 mA @ 33VDC High dBA: 90 mA @ 24VDC High dBA: 165 mA @ 16VDC High dBA: 0.85 mA (from loop) Low dBA: 28 mA @ 33VDC Low dBA: 33 mA @ 24VDC Low dBA: 45 mA @ 16VDC Low dBA: 1.6 mA (from loop) Details for Ordering Model Part Number Description ABHW-4S S54320-F14-A1 Audible (Sounder) Base [designed for sleeping areas] ABHW-4SZ S54320-F14-A2 Sleeping-Room Version (520 Hz) Audible Base, COO – USA Compatible Intelligent Detectors Model Part Number Description OP921 S54320-F4-A2 Optical Detector HI921 S54320-F5-A2 Heat Detector OH921 S54320-F6-A2 Optical / Heat Detector OOH941 S54320-F7-A2 Dual-Optical Heat Detector OOHC941 S54320-F8-A2 Dual-Optical Heat (w/ CO) Detector Compatible Remote Lamps Model Part Number Description RL-HW 500-033310 Remote Alarm Lamp, Wall RL-HC 500-033230 Remote Alarm Lamp, Ceiling Compatible Model ‘H’/ ‘S’ Series Detectors Model Part Number Description HFP-11 500-033290 ‘H’-Series Optical / Heat Detector HFPO-11 500-034800 ‘H’-Series Optical Detector HFPT-11 500-033800 ‘H’-Series Heat Detector SFP-11 500-033290C ‘S’-Series Optical / Heat Detector SFPO-11 500-034800C ‘S’-Series Optical Detector SFPT-11 500-033380C ‘S’-Series Heat Detector Notes: Models SFP-11, SFPO-11 and SFPT-11 detectors are approved exclusively in Canadian installations. Model ‘H’/ ‘S’-series bases are limited in audible-base functionality. Contact Siemens Tech Support at 1-800 248-7976 for more details. ‘Z’ Series Notification Appliances 2584 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety Products Notification Appliances ZH & ZR – Strobes, Horns, & Horn / Strobes Application: Indoor Product Overview – Strobes can be synchronized using the Siemens DSC sync modules, the Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACPs), as well as with:  FireFinder® XLS and MXL® FACPs  PAD-3 or PAD-4™ NAC Extenders with built-in sync protocol – Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (Series ‘ZH’) – Ceiling-mount models feature field-selectable Candela settings of 15/30/75/95cd and 115/177cd – Wall-mount models feature field-selectable Candela settings of 15/30/75/110 cd and 135/185cd – Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted – Strobes produce one (1) flash per second – ``Special Applications” listed with Siemens panels – EZ Mount Universal Mounting Plate (Model ZB Series)  uses single plate for ceiling and wall mount installations – EZ Mount design  with separate base plate  provides ability to pre-wire the base and test the circuit wiring before the walls are covered – UL Listed & ULC Listed, FM (#3028994) Approved; CSFM Approved (Series ‘ZH’: #7125-0067:0248 –> Fire Alarm Devices For The Hearing Impaired) CSFM Approved (Series ‘ZR’: #7125-0067:0252 –> Fire Alarm Devices For The Hearing Impaired) – ADA / NFPA compliant Specifications • General – Audible/Visual notification appliances are listed for indoor use only – Appliances are listed under UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and UL Standard 464 (Fire Protective Signaling) – Appliances use a universal back plate, which allows mounting to a single-gang, double-gang, 4-inch-square (10.2 cm.), 4”-octal (10.2 cm.), or a 3-1/2” (8.9 cm.) octal backbox – Two-wire configurations allows capability for directly connecting appliances to the mounting back plate – Continuity check will occur for entire NAC circuit prior to attaching any audible / visual-notification appliances – A cover fits over the mounting plate for protection to dust and other outside elements  Cover is easily removed when the appliance is installed over the back plate – Removal of an appliance will result in a Trouble condition by the Siemens Fire Alarm Control Panel (FACP) ZR Series ZR & ZH (for mounting) ZH Series s Industry, Inc. Building Technologies Division Specifications – (continued) • Strobes and Audible Strobe Combinations – Strobe appliances produce a minimum flash rate of 60 flashes per minute (one [1] flash per second) over the Regulated Input Voltage Range, and incorporate a Xenon flashtube enclosed in a rugged Lexan® lens – Strobes are available with two (2) or four (4) field-selectable settings in one (1) unit, and are rated – per UL 1971 – for up to: • 15/30/75/110cd for wall mounted • 135/185cd for wall mounted • 15/30/75/95cd for ceiling mounted • 115/177cd for ceiling mounted – Strobes operate over an extended temperature range of 32°F to 120°F (0°C to 49°C), and be listed for maximum humidity of 95% RH – Strobe inputs are polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Siemens FACP • Audible and Audible / Strobe Combinations – Horns and horn / strobes are listed for Indoor use under UL Standard 464 – Horns are able to produce continuous synchronized output or a Temporal Code-3 synchronized output – Horns have at least two (2) sound-level settings of 90 and 95 dBA • Synchronization Modules – The strobe portion, when synchronization is required, is compatible with the Siemens DSC sync modules; the Siemens 50-point, 252-point and 504-point addressable FACPs, as well as with:  FireFinder® XLS and MXL® FACPs  PAD-3 or PAD-4™ NAC Extenders with built-in sync protocol – The strobes will not drift out of synchronization at any time during operation – Audibles and strobes are able to synchronize on a two-wire circuit with the capability to silence the audible, if required – Strobes revert to a non-synchronized flash-rate, if the sync module or power supply should fail to operate (i.e. – contacts remain closed) – All notification appliances are listed for Special Applications:  Strobes are designed to flash at 1-flash-per-second minimum over their ``Regulated Input Voltage Range”  Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second  All candela ratings represent minimum-effective Strobe intensity, based on UL Standard 1971  Series ZH Strobe products are listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%)  Series ZH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only) Mounting Diagram (Shown In Inches) s Industry, Inc. Building Technologies Division Mounting Diagram Technical Data ZH Horn: Wall and Ceiling Mount Operating Voltage (Special Application) Per UL 464 Input Voltage Low* High* DC 16.0 – 33.0VDC 0.018 0.044 FWR 16.0 – 33.0VRMS 0.045 0.075 * Current draw is the same for the Continuous Horn, Code 3 Horn, and March Time settings ZH Horn / Strobe Series: Wall Mount Current Ratings (AMPs) MAXIMUM RMS Current – with High dBA Setting Input Voltage 15cd 30cd 75cd 110cd 135cd 185cd DC 16.0 – 33.0VDC 0.078 0.113 0.195 0.259 0.371 0.506 FWR 16.0 – 33.0VRMS 0.141 0.200 0.302 0.406 0.521 0.722 Current Ratings (AMPs) MAXIMUM RMS Current – with Low dBA Setting Input Voltage 15cd 30cd 75cd 95cd 135cd 185cd DC 16.0 – 33.0VDC 0.070 0.107 0.188 0.246 0.324 0.455 FWR 16.0 – 33.0VRMS 0.123 0.179 0.290 0.391 0.497 0.699 ZR Strobe Series: Wall Mount Current Ratings (AMPs) Strobe Setting – (cd) Input Voltage 15cd 30cd 75cd 110cd 135cd 185cd DC 16.0 – 33.0VDC 0.064 0.098 0.175 0.233 0.318 0.445 FWR 16.0 – 33.0VRMS 0.108 0.164 0.268 0.368 0.482 0.684 ZR Strobe Series: Ceiling Mount Current Ratings (AMPs) Strobe Setting – (cd) Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0 – 33.0VDC 0.069 0.111 0.200 0.264 0.318 0.445 FWR 16.0 – 33.0VRMS 0.117 0.180 0.297 0.398 0.482 0.684 ULC Directional Characteristics -3 dBA 35 degrees left; 40 degrees right -6 dBA 55 degrees left; 65 degrees right ZH Horn / Strobe Series: Ceiling Mount Current Ratings (AMPs) MAXIMUM RMS Current – with High dBA Setting Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0 – 33.0VDC 0.087 0.131 0.222 0.292 0.371 0.506 FWR 16.0 – 33.0VRMS 0.149 0.216 0.331 0.436 0.521 0.722 Current Ratings (AMPs) MAXIMUM RMS Current – with Low dBA Setting Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0 – 33.0VDC 0.075 0.121 0.213 0.277 0.324 0.455 FWR 16.0 – 33.0VRMS 0.131 0.195 0.319 0.421 0.497 0.699 ZH and ZH-MC Series: Wall and Ceiling Mount dBA Sound Output Description Volume Reverberant Per UL 464 16.0 VDC 24.0 VDC 33.0 VDC Continuous Horn Low 77 81 83 High 83 87 90 Code 3 Horn (or March Time)** Low 72 76 79 High 79 82 86 dBA Sound Output Description Volume Reverberant Per ULC-S525-99 20.0 VDC 24.0 VDC 31.0 VDC Continuous Horn Low 88 90 91 High 93 95 96 Code 3 Horn (or March Time)** Low 88 90 91 High 93 95 96 ** Available only in sync mode. s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.usa.Siemens.com/Fire (SII) Printed in U.S.A. Fire Safety 1577 North Service Road East Oakville, Ontario L6H 0H6 / Canada Tel: [905] 465-8000 URL: www.Siemens.CA August 2016 Supersedes sheet dated 6/2015 (Rev. 5) Technical Data – (continued) Notes: 1. Strobes will produce 1 flash per second over the Input Voltage range. 2. These horn/strobe models are UL Listed to operate over a Voltage Range Limit from 16.0VDC to 33.0VDC for 24VDC applications using filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage. 3. All models are UL Listed for indoor ceiling use with a temperature range of +0oC to +49oC (+32oF to +120oF) and maximum humidity of 93% +/- 2% RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance when stored in original cartons, and is not subjected to either misuse or improper handling of shipment. Details for Ordering ─ (Including Mounting Options & Agency Approvals) Model Part Number Description Mounting Options*UL ULC FM CSFM ZH-R 500-636159 Z Horn: Red B,D,E,F,X     ZH-W 500-636160 Z Horn: White B,D,E,F,X     ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F,X     ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F,X     ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F,X     ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela (Wall), White B,D,E,F,X     ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F,X     ZH-MC-CW 500-636166 Z Horn: Multi Candela (Ceiling), White B,D,E,F,X     ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F,X     ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F,X     ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F,X     ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall), White B,D,E,F,X     ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B,D,E,F,X     ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B,D,E,F,X     ZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E,F,X     ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F,X     ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red B,D,E,F,X     ZR-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White B,D,E,F,X     ZB-R 500-636193 Accessory ─ (Includes base, dust cover, mounting screws and installation sheet)    ZB-W 500-636194 Accessory ─ (Includes base, dust cover, mounting screws and installation sheet)      = Listed / Approved * = Refer to data sheet #: 2585 for detailed mounting options Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. Agency Approvals ‘08 Series Notification Appliances 2578 s Industry, Inc. Building Technologies Division s Data Sheet Fire Safety & Security Products ‘08 Series Notification Appliances AS / AH & AS – Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor Product Overview – Fast installation with In / Out screw terminals using #12 to #18 AWG wires – Synchronization can be accomplished using the Siemens DSC sync modules, FS-250 panel, XLS panel, MXL panel, or PAD-3 power supply with built-in sync protocol –3 Selectable dBA settings of 90/95/99 dBA Anechoic in both tones –Selectable Continuous Horn or Temporal (Code 3) –Wall mounts are available with field-selectable Candela settings: 15/30/75/110cd or 135/185cd –Ceiling-mount models are available with field-selectable Candela settings: 15/30/75/95cd or 115/177cd (multi-Candela ceiling models) – Weatherproof models are available for outdoor use – UL Listed & ULC Listed; FM, CSFM & NYMEA Approved – ADA / NFPA / UFC / ANSI compliant Specifications – Notification appliances shall be Siemens Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals – Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired for Indoor Fire Protection Service) – Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling) – All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP) – The audible portion of the appliance shall have a minimum of three (3) field-selectable settings for dBA Anechoic levels, and shall have a choice of continuous or temporal (Code 3) audible outputs – Strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens AS-MC-CW AS-MC-R AH-W AH-R s Industry, Inc. Building Technologies Division Specifications – (continued) – Series AS shall be of low-current design – Strobe intensity, where Multi-Candela appliances are specified, shall have field-selectable settings, and shall be rated per UL Standard 1971 for: ƒ 15/30/75/110cd ƒ 135/185cd – The appliance, when synchronization is required, shall be compatible with Siemens’ DSC Sync Modules or Siemens PAD-3 Power Supplies with built-in Siemens Proprietary Sync Protocol – The strobes shall not drift out of synchronization at any time during operation – The strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. – contacts remain closed) – The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Siemens synchronization – The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBBS Surface Backbox – All notification appliances shall listed for Special Applications: ƒ Strobes are designed to flash at 1-flash-per-second minimum over their “Regulated Input Voltage Range” ¾ Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second ƒ All Candela ratings represent minimum-effective Strobe intensity, based on UL Standard 1971 Mounting Diagram Mounting Options (Shown In Inches) (Shown In Inches) s Industry, Inc. Building Technologies Division Technical Data Notes: 1. Strobe will produce 1 flash per second over the Input Voltage range. 2. This strobe/horn model meets the required light distribution patterns defined in UL 1971 3. This model is UL Listed for indoor use with a temperature range of +32ºF to +120ºF (0ºC to +49ºC) and maximum humidity of 93% + 2% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and not subjected to misuse or abuse. Note: All models are UL / ULC Listed for indoor use with a temperature range of +0°C to +49°C (+32°F to +120°F) and maximum humidity of 93%. s Industry, Inc. Building Technologies Division Technical Data – (continued) Note: These notification appliances are UL Listed as “Special Application”. They are intended to be used only with Siemens notification appliance circuits. Notes: 1. Strobe will produce 1 flash per second over the Input Voltage range. 2. This strobe/horn model meets the required light distribution patterns defined in UL 1971 3. This model is UL Listed for indoor use with a temperature range of +32ºF to +120ºF (0ºC to +49ºC) and maximum humidity of 93% + 2% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and not subjected to misuse or abuse. s Industry, Inc. Building Technologies Division Technical Data – (continued) Details for Ordering ─ (Including Mounting Options & Agency Approvals) Agency Approvals Model Number Part Number Wall Mount Ceiling Mount Description Mounting Options*UL ULC FM CSFM AS-MC-R 500-636010 X ─ AS Horn: Multi-Candela, Red A,B,D,E,F,G,J,N,R,X X X X X AS-MC-W 500-636011 X ─ AS Horn: Multi-Candela, White A,B,D,E,F,G,J,N,R,X X X X X AS-HMC-R 500-636012 X ─ AS Horn: Hi Multi-Candela, Red A,B,D,E,F,G,J,N,R,X X X X X AS-HMC-W 500-636013 X ─ AS Horn: Hi Multi-Candela, White A,B,D,E,F,G,J,N,R,X X X X X AS-MC-CR 500-636006 ─ X AS Horn: Multi-Candela Ceiling, Red A,B,D,E,F,G,J,N,R,X X X X X AS-MC-CW 500-636007 ─ X AS Horn: Multi-Candela Ceiling, White A,B,D,E,F,G,J,N,R,X X X X X AS-HMC-CR 500-636008 ─ X AS Horn: Hi Multi-Candela Ceiling, Red A,B,D,E,F,G,J,N,R,X X X X X AS-HMC-CW 500-636009 ─ X AS Horn: Hi Multi-Candela Ceiling, White A,B,D,E,F,G,J,N,R,X X X X X AS-HMC-CR-WP 500-636181 ─ X AS Horn: Hi Multi-Candela Ceiling Weatherproof, Red I X X X X AS-HMC-CW-WP 500-636182 ─ X AS Horn: Hi Multi-Candela Ceiling Weatherproof, White I X X X X AS-HMC-R-WP 500-636183 X ─ AS Horn: Hi Multi-Candela Wall Weatherproof, Red I X X X X AS-HMC-W-WP 500-636184 X ─ AS Horn: Hi Multi-Candela Wall Weatherproof, White I X X X X AS-75-R-WP 500-636016 X ─ AS Horn: 75CD Weatherproof, Red I X X X X AS-75-CR-WP 500-636015 ─ X AS Horn: 75CD Ceiling Weatherproof, Red I X X X X AH-R 500-636003 X X AH Horn, Red A,B,D,E,F,G,J,N,R,X X X X X AH-W 500-636004 X X AH Horn, White A,B,D,E,F,G,J,N,R,X X X X X AH-R-WP 500-636005 X X AH Horn: Weatherproof, Red K X X X X X = listed / approved *= Refer to data sheet #: 2585 for detailed mounting options s Industry, Inc. Building Technologies Division Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS (SII) Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858 March 2010 Supersedes sheet dated 12/09 (Rev. 2) Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions. MH20845 ® Sealed Rechargeable MODEL PS-1270 F1 12 Volt 7.0 Amp. Hr. Battery www.power-sonic.com Pb L HT H W 6.35 4.75 3.2 F1 F2 0.8 7.95 6.35 3.4 0.8 Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Physical Dimensions: in (mm) Features Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed U.L. recognized under fi le number MH 20845 • • • • • • Performance Specifi cations Nominal Voltage ........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) ........................................................ 7.00 AH 10-hr. (650mA to 10.50 volts) ....................................................... 6.50 AH 5-hr. (1.2A to 10.20 volts) ............................................................ 6.00 AH 1-hr. (4.5A to 9.00 volts) .............................................................. 4.50 AH 15-min. (14A to 9.00 volts) ................................................................. 3.50 AH Approximate Weight ........................................................... 4.80 lbs. (2.18 kg) Energy Density (20-hr. rate) ................................ 1.49 W-h/in3 (90.95 W-h/l) Specifi c Energy (20-hr. rate) .............................. 17.50 W-h/lb (38.58 W-h/kg) Internal Resistance (approx.) ...................................................... 23 milliohms Max Discharge Current (7 Min.) ............................................... 21.0 amperes Max Short-Duration Discharge Current (10 Sec.) .................. 70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ...................................................................................................... 97% 3 Months ..................................................................................................... 91% 6 Months .................................................................................................... 83% Operating Temperature Range Charge .. ........................................................... -4°F (-20°C) to 122°F (50°C) Discharge .......................................................-40°F (-40°C) to 140°F (60°C) Case ......................................................................................................ABS Plastic Power-Sonic Chargers ................................................PSC-12800A, 12800A-C PS-1270 www.power-sonic.comTo ensure safe and effi cient operation always refer to the latest edition of our Technical Manual, as published on our website. All data subject to change without notice. Terminals (mm) 12 Volt 7.0 AH L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) F1 - Quick disconnect tabs, 0.187” x 0.032”- Mate with AMP. INC. FASTON “187” series F2 - Quick disconnect tabs, 0.250” x 0.032” - Mate with AMP. INC FASTON “250” series • • OR CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 Charging Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 70mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage. “Float” or “Stand-By” Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for “C-Series Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our Technical department for advice if you have difficulty in locating suitable models.Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF) 20oC (68oF) 5 oC (41 oF) Chargingisnot necessary unless 100% of capacity is required. Chargingbeforeuse is necessaryto help recoverfull capacity. Chargemayfail to restore full capacity. Do not let batteries reach this state. 100 80 60 40 20 0 0 1 2 3 4 AmbientTemperature 20˚C (68˚F) Float ChargingVoltage 2.25 - 2.30 V/Cell Retention Capacity (%)Years 120 100 80 60 40 20 0 0 200 400 600 800 1000 1200 Number of Cycles 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20oC to 25oC (68oF to 77oF)Retention Capacity (%) Discharge Depth 30% Discharge Depth 100% Discharge Depth 50% Discharge Characteristics Discharge Time vs. Discharge Current Shelf Life & Storage Life Characteristics in Stand-By Use Life Characteristics in Cyclic Use PS-1270 12 Volt 7.0 AH CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 customer-service@power-sonic.com INTERNATIONAL SALES Tel: +1-650-364-5001 Fax: +1-650-366-3662 battery@power-sonic.com DOMESTIC SALES Tel: +1-619-661-2020 Fax: +1-619-661-3650 national-sales@power-sonic.com TECHNICAL SUPPORT Tel: +1-619-661-2020 Fax: +1-619-661-3648 support@power-sonic.com Contact Information www.power-sonic.com Further Information Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. 0308 1M 13.0 12.0 11.0 10.0 9.0 8.0 14.0 Terminal Voltage (V)Ambient Temperature 20oC (68oF) 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time Final Voltage min h 0.350.701.4 3.5 7.0 14 0.35 0.70 1.4 3.5 7.0 14 Discharge Current (A) 20 15 10 5 2 1 30 10 5Discharge Time40oC (104oF) 20oC (68oF) 0oC (32oF)min h10.2V 9.6V 9.0V 8.1V Final Voltage 10.5V Sealed Rechargeable MODEL PS-12120L 12 Volt 12.0 Amp. Hr. Battery www.power-sonic.com PbMH20845 ® L HT H W 6.35 4.75 3.2 F1 F2 0.8 7.95 6.35 3.4 0.8 Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Physical Dimensions: in (mm) Features Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed U.L. recognized under fi le number MH 20845 • • • • • • Performance Specifi cations Nominal Voltage ........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (600mA to 10.50 volts) ....................................................... 12.0 AH 10-hr. (1.19A to 10.50 volts) .......................................................... 11.9 AH 5-hr. (2.21A to 10.20 volts) ........................................................... 11.1 AH 1-hr. (8A to 9.00 volts) .................................................................. 8.00 AH 15-min. (25.5A to 9.00 volts) .............................................................. 6.38 AH Approximate Weight ........................................................... 8.80 lbs. (3.99 kg) Energy Density (20-hr. rate) ................................. 1.08 W-h/in3 (65.77 W-h/l) Specifi c Energy (20-hr. rate) ............................. 16.36 W-h/lb (36.08 W-h/kg) Internal Resistance (approx.) ...................................................... 25 milliohms Max Discharge Current (7 Min.) ............................................... 36.0 amperes Max Short-Duration Discharge Current (10 Sec.) .................. 50.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ...................................................................................................... 97% 3 Months ..................................................................................................... 91% 6 Months .................................................................................................... 83% Operating Temperature Range Charge .. ........................................................... -4°F (-20°C) to 122°F (50°C) Discharge .......................................................-40°F (-40°C) to 140°F (60°C) Case ......................................................................................................ABS Plastic Power-Sonic Chargers ........................................... PSC-122000A, 122000A-C PS-12120L www.power-sonic.comTo ensure safe and effi cient operation always refer to the latest edition of our Technical Manual, as published on our website. All data subject to change without notice. Terminals (mm) FP: Positive: 0.250” x 0.032”, Negative: 0.187” x 0.032”. Mate with AMP. INC FASTON “250/187” series • 12 Volt 12.0 AH L: 8.45 (215) W: 2.75 (70) H: 5.75 (146) HT: 5.75 (146) CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 Charging Cycle Applications: Limit initial current to 3.6A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 120mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage. “Float” or “Stand-By” Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for “C-Series Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our Technical department for advice if you have difficulty in locating suitable models.Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF) 20oC (68oF) 5 oC (41 oF) Chargingisnot necessary unless 100% of capacity is required. Chargingbeforeuse is necessaryto help recoverfull capacity. Chargemayfail to restore full capacity. Do not let batteries reach this state. 100 80 60 40 20 0 0 1 2 3 4 AmbientTemperature 20˚C (68˚F) Float ChargingVoltage 2.25 - 2.30 V/Cell Retention Capacity (%)Years 120 100 80 60 40 20 0 0 200 400 600 800 1000 1200 Number of Cycles 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20oC to 25oC (68oF to 77oF)Retention Capacity (%) Discharge Depth 30% Discharge Depth 100% Discharge Depth 50% Discharge Characteristics Discharge Time vs. Discharge Current Shelf Life & Storage Life Characteristics in Stand-By Use Life Characteristics in Cyclic Use PS-12120L 12 Volt 12.0 AH CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 customer-service@power-sonic.com INTERNATIONAL SALES Tel: +1-650-364-5001 Fax: +1-650-366-3662 battery@power-sonic.com DOMESTIC SALES Tel: +1-619-661-2020 Fax: +1-619-661-3650 national-sales@power-sonic.com TECHNICAL SUPPORT Tel: +1-619-661-2020 Fax: +1-619-661-3648 support@power-sonic.com ® Contact Information www.power-sonic.com Further Information Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. 0309 1M 13.0 12.0 11.0 10.0 9.0 8.0 14.0 Terminal Voltage (V)Ambient Temperature 20oC (68oF) 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time Final Voltage min h 0.601.22.4 6.0 12 24 0.60 1.2 2.4 6.0 12 24 Discharge Current (A) 20 15 10 5 2 1 30 10 5Discharge Time40oC (104oF) 20oC (68oF) 0oC (32oF)min h10.2V 9.6V 9.0V 8.1V Final Voltage 10.5V