75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Fire - Construction Permit A18-0063 Issued: 01/22/2019 TOWN OF VAIL Property Information Address: 3245 KATSOS RANCH RD E (210102301041 E) ( 210102301041 ) Unit #: E Parcel Number: 210102301041 Legal Description: Subdivision: VAIL VILLAGE FILING 12 Block: 1 Lot: 8 PARCEL A BK-0245 PG-0783 WD 03-25-76 BK- 0592 PG-0770 WD 10-19-92 Contacts Contact Type: Applicant Full Name: Don Anderson Address: PO Box 3940 331 Metcalf Rd Avon, CO 81620 Phone: 9707488888 Contact Type: Property Owner Full Name: JOHNSON, TAIT GARRETT WILLIAM & SARAH POHLMANN Address: Phone: None Contractor Contractor Type: Fire Protection Company: Meridian Intermountain/Vail Electronics State License #:Phone: 970-748-8888 Project Information Project Name: Johnson Residence 2018 (3245 Katsos Ranch Rd) Project Description: Fire Alarm Install Fees Paid Account #: 001-0000.31111.00 - Fire Alarm Permit Fee Fee Amount:$75.10 Account #: 001-0000.31123.00 - Fire Alarm Review Fee Fee Amount:$432.00 Total Paid:$507.10 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. In addition, the VISTA-20P, used with an AlarmNet Internet or digital communicator can be installed in premises without TELCO lines with no sacrifice in functionality. The panels installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations. FEATURES VISTA-20P CONTROL PANEL IP alarm reporting and uploading/downloading capability for Internet and Intranet use via 7845i, 7845i-ENT, 7845GSMR or 7845i-GSM Supports four graphic touchscreen keypads Wireless keys can be programmed without using zones Eight on-board hardwired zones standard (15 when Zone Doubling feature is used) 40 hardwire expansion zones 40 wireless expansion zones Two low current on-board trigger outputs 100 Event Log viewable at system keypads with time/date stamp 48 system user codes assignable to either partition Expandable to 48 total zones when used with hardwired and/or wireless expansion modules Two independent partitions plus a common partition Global Arming from any system keypad Goto function to view or operate one partition from the other Separate partition account numbers 16 output devices Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10® devices (when used with a 4300 Transformer) Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes Supports four-wire and up to 16 two-wire smokes Works with Sentrol CleanMe maintenance signal Multiple actions on output devices depending on system state Turns lights off when system arms Turns the same light on when system disarms Flashes same lights when system is in alarm Built-in phone line cut monitor with programmable delay and annunciation options Display on system keypads Trigger local sounders Trigger system bell Security Dealer Features Automatic System Load Shed During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries. Dynamic Signaling Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio Valuable End-User Features Viewable on system keypads: Exit countdown Time and date display* Event log* Auto keypad backlighting on entry Keyswitch arming Programmable macro buttons and single-button arming Supports a variety of wireless remote controls for single-button operation User Scheduling Automatically activates X-10 and relays at programmed times Latchkey reports to pagers Auto arm/disarm User access time windows Supports up to four end-user numeric pagers VIP Module allows system control from any touchtone phone Chime by zone * Requires custom alpha keypad ORDERING VISTA-20P Control Panel VISTA-20P CONTROL PANEL Electrical Aux. power 12VDC, 600mA maximum Seven hour standby at 400mA aux. load with four amp hour battery 16.5VAC/25VA transformer Alarm output 12VDC, 2.0 amps max. - For UL installations, combined aux. and alarm output cannot exceed 700mA Output Control Supports up to four relay boards (up to 16 relays) Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices Zones Eight hardwired zones (15 with zone doubling) Selectable response 10msec, 350msec, 750msec Assignable to any partition 20 selectable zone types plus four configurable zone types Programmable swinger suppression Expansion Devices 4219 Eight hardwired zones 16mA 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA) 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA) Accessories 7845i Internet Communicator 7845i-ENT Enterprise Internet Communicator 7845GSMR Dual-Path Digital Wireless Communicator 7845i-GSM Triple-Path Digital Communicator 4286 VIP Voice Module 220mA 5881ENL RF Receiver supports up to eight zones 60mA 5881ENM supports up to 16 zones 50mA 5881ENH supports up to 48 zones 50mA 5883 Transceiver supports up to 40 zones 80mA Supports Eagle 1225 and 1221 boards Keypads 6160 Custom Alpha (required for programming) 100mA 6160V Custom Alpha Voice 100mA 6150 Fixed English LCD 85mA/40mA 6150V Fixed English Voice LCD 85mA/40mA 6150RF Fixed English RF LCD 85mA/40mA 6148 Fixed English LCD 70mA/30mA 6270 Graphic Touchscreen 6271V Graphic Touchscreen with Voice 6271C Color Graphic Touchscreen 6271CV Color Graphic Touchscreen with Voice 8132 Advanced User Interface Agency Listings UL Residential Fire, Burglary and CSFM Smoke Detectors Supports up to 16 two-wire smoke detectors Supports four-wire smoke detectors Communications 7845i Internet Communicator 7845i-ENT Enterprise Internet Communicator 7845GSMR Dual-Path Digital Wireless Communicator 7845i-GSM Triple-path Digital Communicator Touchtone or pulse Formats supported ADEMCO Contact ID ADEMCO 4 + 2 Express ADEMCO low speed Sescoa/Radionics 3 + 1, 4 + 1 and 4 + 2 reporting Reporting capabilities Split Dual Split/Dual True dial tone detection Low battery reports 11.2 11.6VDC AC loss and restoral reporting supported SPECIFICATIONS L/VISTA20P/D September 2008 © 2008 Honeywell International Inc. Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com Agency Listings Smoke Detectors with Sounder and Relay Option System Sensor i3™ sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Features • 85 dB sounder • Form C relay • Isolated thermal sensor • Plug-in design (base included) • In-line terminals • Flexible mounting options • Stop-Drop ’N Lock™ attachment to the base • Removable cover and chamber • Remote maintenance signaling • Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Dual-color LEDs Installation ease. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop ’N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready™ panel, 2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Instant inspection. i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated. 2133 372-02-E 7272-1653:164 3015195 S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0348-004 • 6/09 • #2170 Ordering Information Model Thermal Wiring Alarm Current 2WTA-B Yes 2-wire 130 mA max. limited by control panel 2WTR-B Yes 2-wire 130 mA max. limited by control panel 4WTA-B Yes 4-wire 35 mA 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA Smoke Detector Specifications Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized 2-wire: 8.5 V to 35 V 4-wire: 10 V to 35 V Maximum Ripple Voltage 30% of applied voltage (peak to peak) Standby Current 2-wire: 50 µA maximum average 4-wire: 50 µA maximum average Peak Standby Current 2-wire: 100 µA 4-wire: n/a Maximum Alarm Current 2-wire: 2WTR-B: 130 mA limited by control panel 2WTA-B: 130 mA** 4-wire: 4WTA-B, 4WTR-B: 35 mA 4WTAR-B, 4WITAR-B: 50 mA **Direct Power (Non-Reverse Polarity): 130 mA limited by panel. Reverse Polarity Power: 30 mA for the 2WTA-B in alarm; 12 mA for all other 2WTA-B units on the loop. Add 25 mA for the RRS-MOD reversing relay alarm current. Alarm Contact Ratings 2-wire: n/a 4-wire: 0.5 A @ 30 V AC/DC Form C Contact Ratings 2 A @ 30 V AC/DC Physical Specifications Operating Temperature Range 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 41°F (5°C) Sensitivity 2.5%/ft. nominal Input Terminals 14–22 AWG Dimensions (including base) 5.3 inches (134 mm) diameter, 2.0 inches (51 mm) height Approximate Weight 7.1 oz (200 g) Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B, and 4WITAR-B only) Mounting 3½-inch octagonal back box, 4-inch octagonal back box, single-gang back box, 4-inch square back box with a plaster ring, direct mount to ceiling LED Modes LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Power-Up Sequence for LED Indication Condition Duration Initial LED status indication 80 seconds Architect/Engineer Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a combination photoelectric/thermal equipped with a sounder (model 2WTA-B, 4WTA-B), a Form C relay (model 2WTR-B), a combination sounder/relay (model 4WTAR-B), or an isolated thermal/sounder/relay (model 4WITAR-B). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power-up, normal standby, out of sensitivity, alarm, and freeze trouble conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. When used in conjunction with the RRS-MOD module, all i3 sounder models on a loop shall sound when one sounder alarms, all shall be synchronized, and all sounders may be silenced from the panel. Model Description RRS-MOD Reversing relay/synchronization module 2W-MOD2 2-wire loop test/maintenance module SENS-RDR Sensitivity reader RT Removal/replacement tool A77-AB2 Retrofit adapter bracket i4 Series Combination CO/Photoelectric Smoke Detector Best-in-class carbon monoxide (CO) and smoke detection technology in a single, system-connected device. Features • Single device for CO and smoke detection that uses less wiring and fewer junction boxes • Compatible with a wide range of control panels with the use of the required i4 Interface Module. • Sends distinct smoke and CO signals to the panel • Sounds Temporal 3 for smoke and Temporal 4 for CO • Built-in 85dB sounder • LEDs display both CO and smoke status • External IR LED provides extended range sensitivity testing • Versatile mounting allows for wall or ceiling placement • Easily replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner • RealTest® enables functional test using canned CO • Drift compensation and smoothing algorithms provide false alarm immunity • Compatible with SENS-RDR sensitivity tester • Full agency compliance with UL 268 and UL 2075 Integration: The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than two separate devices. The i4 Series is compatible with i3 (2WTA-B or 4WTA-B), so an attractive CO monitoring solution can easily be retrofitted into existing i3 installations. The i4 Series CO cell can be easily replaced at end-of-life, resulting in a much lower life cost than having to replace the entire detector. Installation ease: The i4 Series Combination CO/Smoke detector requires less wiring than two separate CO and smoke devices. Installers can pre-wire its plug-in base, while its large wire-entry port and in-line terminals provide ample room for neatly routing wiring. The base accommodates several back box options and also direct mounts using drywall anchors. The i4 head plugs into the base with a simple Stop-Drop `N Lock™ action. When the detector’s CO cell reaches end- of-life, it can be easily replaced in the field without a tool. Intelligence: With the help of the module, the i4 Series transmits distinct CO and smoke signals, allowing appropriate response from the central monitoring station. Intelligent features, such as drift compensation and smoothing algorithms, reduce nuisance alarms. Instant inspection: The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition, alarm condition, maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device. CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720: 2009 requirements using the detector’s RealTest functionality. 4 Agency Listings S268 1653:0227 Physical Specifications Dimension: Diameter: 5.5˝; Depth: 2.5˝ (includes base) Weight: 9.2 oz. (261 g) Operating Temperature Range: 0 – 50° C (32 – 122° F) Operating Humidity Range: 20-95% RH Storage Temperature Range: -10 – 70° C (14 – 158° F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes: 3.5˝ and 4˝ Octagonal; Single-gang; 4˝ Square; 2 x 4˝, 3.5˝ and 4˝ round ceiling. Direct mount to wall or ceiling. Electrical Specifications Operating Voltage (VDC): Nominal: 12/24; Minimum: 8.5; Maximum: 35 Maximum Standby Current: 50 µA Maximum Alarm Current: 2-Wire 50mA; 4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 µF Operation Modes / LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke & CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest® Mode (CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide (CO)/Smoke detector shall be a System Sensor model number COSMO-2W (2-Wire) / COSMO-4W (4-Wire) listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection. The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals. The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface mount) to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide LED indication that blinks to indicate normal standby, smoke alarm, smoke maintenance, CO alarm, CO trouble/end-of-life. When the detector is in CO trouble condition, it shall send a trouble signal to the panel. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. The detector shall have a replaceable CO cell that can be replaced at end of cell life. Features • Easily integrates up to 12 compatible detectors to a wide range of control panels • 2-wire module is compatible with COSMO-2W combination detectors and 2WTA-B smoke detectors. • 4-wire module is compatible with COSMO-4W combination detectors and 4WTA-B smoke detectors. • Sends distinct smoke and CO signals from i4 detectors to the panel • LED indication shows when a detector on the loop requires cleaning or maintenance (2-wire detectors only) • Initiates the EZ Walk loop test (2-wire detectors only) • Module interconnects the sounders of all devices connected to it. No RSS-MOD is required. Optional trigger inputs are provided to sound multiple modules. i4 Series Interface and Reversing Relay Module The i4 Interface Module connects up to 12 detectors to a wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Integration: The i4 module allows up to 12 i4 Series or compatible i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones: a smoke zone, a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp 4 for CO events. The i4 module can be used to alarm all sounders in compatible detectors for smoke and CO events. When one detector detects smoke or CO and goes into alarm, all connected detectors alarm, offering the highest level of warning to the homeowner. Installation ease: The i4 Series Interface Module mounts to a 411/16-inch square back box for quick and easy installation. Terminal blocks with durable SEMS screws ensure a reliable connection. It also has pre-drilled holes for easy mounting inside a metal enclosure Intelligence: The i4 Interface Module allows i4 and compatible i3 smoke detector models (2WTA-B and 4WTA-B) to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection: The i4 Interface Module provides LED status indication for the loop, displaying normal operation, loop wiring fault, smoke events, smoke maintenance (2-wire only), CO events, and CO maintenance/end-of-life. Agency Listings S911 1653:0228 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. CODS30302 • 11/13 Ordering Information Part No. Description COSMO-2W 12/24 volt, 2-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt, 4-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module (required to use with COSMO-2W models) COSMOD4W 4-wire interface module (required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay (required with 4-wire systems) Module Power-Up Sequence / LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Operation Modes / LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke & CO: Blink 1 sec. Off On On No power / No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode (2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance (2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble (i3 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Electrical Specifications Module Operating Voltage (VDC): Nom.: 12/24; Min.: 8.5 (2-wire), 10 (4-wire, power limited); Max.: 35 VDC (power limited) Standby Current: 2-Wire: 61mA (max.), 45mA (12V In), 26mA (24V In); 4-Wire: 52mA1 (max.), 37mA1 (12V In), 22mA1 (24V In) Alarm Current2: 2-Wire: 181mA (max.), 121mA (12V In), 64mA (24V In); 4-Wire: 78mA1 (max.), 57mA1 (12V In), 34mA1 (24V In) Maximum Ripple Voltage: 30% of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA @ 36 Volts DC, resistive, 25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms; 4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V; Max.: Vin 1 Does not include current draw from attached detectors or EOL relay. 2 Does not include reverse polarity current draw from attached detectors. i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W (2-wire) or COSMOD4W (4-wire) listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws. The module shall provide 4 LED indicators that blink or illuminate to indicate communication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode (2-wire module only). The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864- and UL 985-listed fire alarm control panel capable of utilizing this module. The 2-wire module shall offer provisions for Style D / Class A wiring on IDC loops and shall provide a loop testing capability (EZ Walk) to verify the initiating loop wiring. Physical Specifications Module Dimension: Height: 6.04˝; Width: 6.04˝; Depth: 1.00˝ Weight: 9.6 oz. 272 (g) Operating Temperature Range: 0 – 50° C (32 – 122° F) Operating Humidity Range: 5 - 95% RH Storage Temperature Range: -20 – 70° C (-4 – 158° F) Input Terminals: 14 to 22 AWG Mounting: 411/16˝ square back box or inside a metal enclosure i4 Series Combination CO/Photoelectric Smoke Detector Best-in-class carbon monoxide (CO) and smoke detection technology in a single, system-connected device. Features • Single device for CO and smoke detection that uses less wiring and fewer junction boxes • Compatible with a wide range of control panels with the use of the required i4 Interface Module. • Sends distinct smoke and CO signals to the panel • Sounds Temporal 3 for smoke and Temporal 4 for CO • Built-in 85dB sounder • LEDs display both CO and smoke status • External IR LED provides extended range sensitivity testing • Versatile mounting allows for wall or ceiling placement • Easily replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner • RealTest® enables functional test using canned CO • Drift compensation and smoothing algorithms provide false alarm immunity • Compatible with SENS-RDR sensitivity tester • Full agency compliance with UL 268 and UL 2075 Integration: The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than two separate devices. The i4 Series is compatible with i3 (2WTA-B or 4WTA-B), so an attractive CO monitoring solution can easily be retrofitted into existing i3 installations. The i4 Series CO cell can be easily replaced at end-of-life, resulting in a much lower life cost than having to replace the entire detector. Installation ease: The i4 Series Combination CO/Smoke detector requires less wiring than two separate CO and smoke devices. Installers can pre-wire its plug-in base, while its large wire-entry port and in-line terminals provide ample room for neatly routing wiring. The base accommodates several back box options and also direct mounts using drywall anchors. The i4 head plugs into the base with a simple Stop-Drop `N Lock™ action. When the detector’s CO cell reaches end- of-life, it can be easily replaced in the field without a tool. Intelligence: With the help of the module, the i4 Series transmits distinct CO and smoke signals, allowing appropriate response from the central monitoring station. Intelligent features, such as drift compensation and smoothing algorithms, reduce nuisance alarms. Instant inspection: The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition, alarm condition, maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device. CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720: 2009 requirements using the detector’s RealTest functionality. 4 Agency Listings S268 1653:0227 Physical Specifications Dimension: Diameter: 5.5˝; Depth: 2.5˝ (includes base) Weight: 9.2 oz. (261 g) Operating Temperature Range: 0 – 50° C (32 – 122° F) Operating Humidity Range: 20-95% RH Storage Temperature Range: -10 – 70° C (14 – 158° F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes: 3.5˝ and 4˝ Octagonal; Single-gang; 4˝ Square; 2 x 4˝, 3.5˝ and 4˝ round ceiling. Direct mount to wall or ceiling. Electrical Specifications Operating Voltage (VDC): Nominal: 12/24; Minimum: 8.5; Maximum: 35 Maximum Standby Current: 50 µA Maximum Alarm Current: 2-Wire 50mA; 4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 µF Operation Modes / LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke & CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest® Mode (CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide (CO)/Smoke detector shall be a System Sensor model number COSMO-2W (2-Wire) / COSMO-4W (4-Wire) listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection. The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals. The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface mount) to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide LED indication that blinks to indicate normal standby, smoke alarm, smoke maintenance, CO alarm, CO trouble/end-of-life. When the detector is in CO trouble condition, it shall send a trouble signal to the panel. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. The detector shall have a replaceable CO cell that can be replaced at end of cell life. Features • Easily integrates up to 12 compatible detectors to a wide range of control panels • 2-wire module is compatible with COSMO-2W combination detectors and 2WTA-B smoke detectors. • 4-wire module is compatible with COSMO-4W combination detectors and 4WTA-B smoke detectors. • Sends distinct smoke and CO signals from i4 detectors to the panel • LED indication shows when a detector on the loop requires cleaning or maintenance (2-wire detectors only) • Initiates the EZ Walk loop test (2-wire detectors only) • Module interconnects the sounders of all devices connected to it. No RSS-MOD is required. Optional trigger inputs are provided to sound multiple modules. i4 Series Interface and Reversing Relay Module The i4 Interface Module connects up to 12 detectors to a wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Integration: The i4 module allows up to 12 i4 Series or compatible i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones: a smoke zone, a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp 4 for CO events. The i4 module can be used to alarm all sounders in compatible detectors for smoke and CO events. When one detector detects smoke or CO and goes into alarm, all connected detectors alarm, offering the highest level of warning to the homeowner. Installation ease: The i4 Series Interface Module mounts to a 411/16-inch square back box for quick and easy installation. Terminal blocks with durable SEMS screws ensure a reliable connection. It also has pre-drilled holes for easy mounting inside a metal enclosure Intelligence: The i4 Interface Module allows i4 and compatible i3 smoke detector models (2WTA-B and 4WTA-B) to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection: The i4 Interface Module provides LED status indication for the loop, displaying normal operation, loop wiring fault, smoke events, smoke maintenance (2-wire only), CO events, and CO maintenance/end-of-life. Agency Listings S911 1653:0228 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. CODS30302 • 11/13 Ordering Information Part No. Description COSMO-2W 12/24 volt, 2-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt, 4-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module (required to use with COSMO-2W models) COSMOD4W 4-wire interface module (required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay (required with 4-wire systems) Module Power-Up Sequence / LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Operation Modes / LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke & CO: Blink 1 sec. Off On On No power / No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode (2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance (2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble (i3 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Electrical Specifications Module Operating Voltage (VDC): Nom.: 12/24; Min.: 8.5 (2-wire), 10 (4-wire, power limited); Max.: 35 VDC (power limited) Standby Current: 2-Wire: 61mA (max.), 45mA (12V In), 26mA (24V In); 4-Wire: 52mA1 (max.), 37mA1 (12V In), 22mA1 (24V In) Alarm Current2: 2-Wire: 181mA (max.), 121mA (12V In), 64mA (24V In); 4-Wire: 78mA1 (max.), 57mA1 (12V In), 34mA1 (24V In) Maximum Ripple Voltage: 30% of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA @ 36 Volts DC, resistive, 25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms; 4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V; Max.: Vin 1 Does not include current draw from attached detectors or EOL relay. 2 Does not include reverse polarity current draw from attached detectors. i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W (2-wire) or COSMOD4W (4-wire) listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws. The module shall provide 4 LED indicators that blink or illuminate to indicate communication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode (2-wire module only). The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864- and UL 985-listed fire alarm control panel capable of utilizing this module. The 2-wire module shall offer provisions for Style D / Class A wiring on IDC loops and shall provide a loop testing capability (EZ Walk) to verify the initiating loop wiring. Physical Specifications Module Dimension: Height: 6.04˝; Width: 6.04˝; Depth: 1.00˝ Weight: 9.6 oz. 272 (g) Operating Temperature Range: 0 – 50° C (32 – 122° F) Operating Humidity Range: 5 - 95% RH Storage Temperature Range: -20 – 70° C (-4 – 158° F) Input Terminals: 14 to 22 AWG Mounting: 411/16˝ square back box or inside a metal enclosure MH20845 ® Sealed Rechargeable MODEL PS-1270 F1 12 Volt 7.0 Amp. Hr. Battery www.power-sonic.com Pb L HT H W 6.35 4.75 3.2 F1 F2 0.8 7.95 6.35 3.4 0.8 Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Physical Dimensions: in (mm) Features Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed U.L. recognized under fi le number MH 20845 • • • • • • Performance Specifi cations Nominal Voltage ........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) ........................................................ 7.00 AH 10-hr. (650mA to 10.50 volts) ....................................................... 6.50 AH 5-hr. (1.2A to 10.20 volts) ............................................................ 6.00 AH 1-hr. (4.5A to 9.00 volts) .............................................................. 4.50 AH 15-min. (14A to 9.00 volts) ................................................................. 3.50 AH Approximate Weight ........................................................... 4.80 lbs. (2.18 kg) Energy Density (20-hr. rate) ................................ 1.49 W-h/in3 (90.95 W-h/l) Specifi c Energy (20-hr. rate) .............................. 17.50 W-h/lb (38.58 W-h/kg) Internal Resistance (approx.) ...................................................... 23 milliohms Max Discharge Current (7 Min.) ............................................... 21.0 amperes Max Short-Duration Discharge Current (10 Sec.) .................. 70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ...................................................................................................... 97% 3 Months ..................................................................................................... 91% 6 Months .................................................................................................... 83% Operating Temperature Range Charge .. ........................................................... -4°F (-20°C) to 122°F (50°C) Discharge .......................................................-40°F (-40°C) to 140°F (60°C) Case ......................................................................................................ABS Plastic Power-Sonic Chargers ................................................PSC-12800A, 12800A-C PS-1270 www.power-sonic.comTo ensure safe and effi cient operation always refer to the latest edition of our Technical Manual, as published on our website. All data subject to change without notice. Terminals (mm) 12 Volt 7.0 AH L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) F1 - Quick disconnect tabs, 0.187” x 0.032”- Mate with AMP. INC. FASTON “187” series F2 - Quick disconnect tabs, 0.250” x 0.032” - Mate with AMP. INC FASTON “250” series • • OR CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 Charging Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 70mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to “float” voltage. “Float” or “Stand-By” Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for “C-Series Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our Technical department for advice if you have difficulty in locating suitable models.Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF) 20oC (68oF) 5 oC (41 oF) Chargingisnot necessary unless 100% of capacity is required. Chargingbeforeuse is necessaryto help recoverfull capacity. Chargemayfail to restore full capacity. Do not let batteries reach this state. 100 80 60 40 20 0 0 1 2 3 4 AmbientTemperature 20˚C (68˚F) Float ChargingVoltage 2.25 - 2.30 V/Cell Retention Capacity (%)Years 120 100 80 60 40 20 0 0 200 400 600 800 1000 1200 Number of Cycles 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20oC to 25oC (68oF to 77oF)Retention Capacity (%) Discharge Depth 30% Discharge Depth 100% Discharge Depth 50% Discharge Characteristics Discharge Time vs. Discharge Current Shelf Life & Storage Life Characteristics in Stand-By Use Life Characteristics in Cyclic Use PS-1270 12 Volt 7.0 AH CUSTOMER SERVICE Tel: +1-619-661-2030 Fax: +1-619-661-3648 customer-service@power-sonic.com INTERNATIONAL SALES Tel: +1-650-364-5001 Fax: +1-650-366-3662 battery@power-sonic.com DOMESTIC SALES Tel: +1-619-661-2020 Fax: +1-619-661-3650 national-sales@power-sonic.com TECHNICAL SUPPORT Tel: +1-619-661-2020 Fax: +1-619-661-3648 support@power-sonic.com Contact Information www.power-sonic.com Further Information Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. 0308 1M 13.0 12.0 11.0 10.0 9.0 8.0 14.0 Terminal Voltage (V)Ambient Temperature 20oC (68oF) 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time Final Voltage min h 0.350.701.4 3.5 7.0 14 0.35 0.70 1.4 3.5 7.0 14 Discharge Current (A) 20 15 10 5 2 1 30 10 5Discharge Time40oC (104oF) 20oC (68oF) 0oC (32oF)min h10.2V 9.6V 9.0V 8.1V Final Voltage 10.5V