HomeMy WebLinkAboutB16-0490_A402_1501275578.pdf1 - CREEK LEVEL 8,168' - 6 5/8" 2 - STREET LEVEL 8,178' - 2 3/8" 3 - LEVEL 2 8,188' - 3 5/8" 4 - LEVEL 3 8,197' - 9 5/8" 5 - ROOF 8,208' - 6 5/8" 2 2 A301 A500 7 Project number Date Drawn by 1/7/2017 12:30:47 PM A402 WALL SECTIONS 000000 VAIL ROWHOUSES, VAIL COLORADO ROW HOUSE 12 1/4/2017 Author No. Description Date 1 PERMIT SUBMITTAL 12 DEC 16 IECC NOTES FOR WALLS, ROOF, SLAB, FLOORS, & WINDOWS: WALLS (ABOVE GRADE): · R-23 CAVITY FOR EXTERIOR 2X6 WALLS - 2" CLOSED CELL (R-13.4) + 3 1/2" BIBS (R-15) TOTAL = R-28.4 WALLS (BELOW GRADE): · R-10 CONTINUOUS + R-13 CAVITY (R-23 NOM) **INSULATION/DRAINAGE BOARD (R-10)+1.5" CLOSED CELL (R-10.05) AT INT FURRED. TOTAL = R-20.05 WALLS (BETWEEN ROOMS & CRAWLSPACE): · R-19 CAVITY. CRAWL CEILING - BIBS (R-45). 2X4 INT WALLS - BATT (R-11). 2X6 INT WALL - BATT (R-19). ROOF: · R-36 CAVITY + R-20 CONTINUOUS (R-55 NOM)**2" CLOSED CELL (R-13.4) + 10" BIBS (R-38). TOTAL = R-51.4 SLAB (HEATED): · R-15 CONTINUOUS. 2" RIGID UNDER SLAB INSULATION = R-10 FLOORS: · R-30 CAVITY MID FLOOR = R-19 BATT. WINDOWS: · U-0.30, SHGC = 0.3 SKYLIGHTS: U-0.4**, SHGC = 0.3 07/28/17