Loading...
HomeMy WebLinkAboutTest Balance Report FC123.pdfTable Of ContentsPROJECT:LOCATION:MARRIOTT - VAILVAIL, CO 2654PROJECT #: DATE:CONTACT:1/6/2019 Table Of Contents1 Fan Unit....................................................................................................................................................................1 1.1 FC-01..................................................................................................................................................................1 1.2 FC-02..................................................................................................................................................................2 1.3 FC-03..................................................................................................................................................................3 2 Hydronic Pump.........................................................................................................................................................4 3 VAIL MARRIOTT CBC RPT DRAWINGS.pdf...........................................................................................................5 Certified Balancing and Commissioning “All I have in this world is my faith and my word, I don’t break them for anyone” Fan UnitPROJECT:LOCATION:MARRIOTT - VAILVAIL, CO 2654PROJECT #: DATE:CONTACT:1/6/2019 Tested By:Greg Barnes Date:1/6/2019 SYSTEM/UNIT: FC-01 Log:FC-01 1/6/2019 Greg Barnes FAN ON HIGH SPEED, NO INDIVIDUAL DAMPERS. Unit Data Fan Manufacturer ENVIRO-TEC Fan Model Number HM Fan Serial Number 6LFM001134 Starter Data Starter Manufacturer FACTORY INSTALLED Test Data Design Airflow 2000 CFM Actual Airflow 1485 CFM Motor Data Motor HP 1/2 HP Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 7.24 Amps System/Unit Outlet Type Size LxW / D AK Factor Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Outlet-01 CD 24X24 1.00 500 280 56 280 56 Outlet-02 CD 24X24 1.00 500 400 80 400 80 Outlet-03 CD 24X24 1.00 500 405 81 405 81 Outlet-04 CD 24X24 1.00 500 400 80 400 80 Totals:---2000 1485 74 1485 74 FC-01 Supply Outlet Summary Certified Balancing and Commissioning Page 1 of 8 “All I have in this world is my faith and my word, I don’t break them for anyone” Fan UnitPROJECT:LOCATION:MARRIOTT - VAILVAIL, CO 2654PROJECT #: DATE:CONTACT:1/6/2019 Tested By:Greg Barnes Date:1/6/2019 SYSTEM/UNIT: FC-02 Unit Data Fan Manufacturer ENVIRO-TEC Fan Model Number HLF Fan Serial Number 6LFM001294 Starter Data Starter Manufacturer FACTORY INSTALLED Test Data Design Airflow 800 CFM Actual Airflow 800 CFM Motor Data Motor HP 1/6 HP Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 4.20 Amps Motor Service Factor 1.15 System/Unit Outlet Type Size LxW / D AK Factor Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Outlet-01 SLOT 48 200 210 105 210 105 Outlet-02 SLOT 48 200 180 90 180 90 Outlet-03 SLOT 48 200 205 103 205 103 Outlet-04 SLOT 48 200 205 103 205 103 Totals:---800 800 100 800 100 FC-02 Supply Outlet Summary Certified Balancing and Commissioning Page 2 of 8 “All I have in this world is my faith and my word, I don’t break them for anyone” Fan UnitPROJECT:LOCATION:MARRIOTT - VAILVAIL, CO 2654PROJECT #: DATE:CONTACT:1/6/2019 Tested By:Greg Barnes Date:1/6/2019 SYSTEM/UNIT: FC-03 Unit Data Fan Manufacturer ENVIRO-TEC Fan Model Number HLF Fan Serial Number 6LFM001293 Starter Data Starter Manufacturer FACTORY INSTALLED Test Data Design Airflow 800 CFM Actual Airflow 820 CFM Motor Data Motor HP 1/6 HP Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 4.20 Amps Motor Service Factor 1.15 System/Unit Outlet Type Size LxW / D AK Factor Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Outlet-01 SLOT 48 140 135 96 135 96 Outlet-02 SLOT 48 110 120 109 120 109 Outlet-03 SLOT 48 110 110 100 110 100 Outlet-04 SLOT 48 110 100 91 100 91 Outlet-05 SLOT 48 110 120 109 120 109 Outlet-06 SLOT 48 110 115 105 115 105 Outlet-07 SLOT 48 110 120 109 120 109 Totals:---800 820 103 820 103 FC-03 Supply Outlet Summary Certified Balancing and Commissioning Page 3 of 8 “All I have in this world is my faith and my word, I don’t break them for anyone” Hydronic PumpPROJECT:LOCATION:MARRIOTT - VAILVAIL, CO 2654PROJECT #: DATE:CONTACT:1/6/2019 System/Unit Manufacturer Model Number Valve Size d.GPM a.GPM Design D.P.Final D.P.Valve Position FC-01 GRISWOLD 4.2CV 1”8.1 2.9 100 FC-02 GRISWOLD 4.2CV 1”8.3 1.5 100 FC-03 GRISWOLD 4.2CV 1”8.3 1.5 100 Totals:---24.7 5.9 --- (E) CWP Balance Valve Summary System/Unit Manufacturer Model Number Valve Size d.GPM a.GPM Design D.P.Final D.P.Valve Position FC-01 GRISWOLD 4.2CV 1”8.1 3.8 100 FC-02 GRISWOLD 4.2CV 1”3.4 3.4 70 FC-03 GRISWOLD 4.2CV 1”3.4 3.5 70 Totals:---14.9 10.7 --- (E) HWP Balance Valve Summary Certified Balancing and Commissioning Page 4 of 8 “All I have in this world is my faith and my word, I don’t break them for anyone” PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 5/15/20181:10:17PMVAILMARRIOTT715WLionsheadCir.Vail,CO8165716-106-00 arv arv 09/14/18 COLORADO BALLROOM MODIFICATIONS arv 11/19/2018 8 11/19/18 CONF RM 234 As indicated GENERAL NOTES, LEGEND M1.0.0 Outside Air Schedule Mech Unit Zone Occupant Load Outdoor Air Zone Outdoor Air Flow Floor Area Zone Area Distribution Calc Zone Outdoor Design Zone Total Air Occupancy (People/1000sf) Flow Rate/person Population Rate Req'd/Area Effectiveness Air Flow Outdoor Air Flow Provided (Rp)(Pz)(Ra)(Az)(Ez)(CFM)(CFM)(CFM) F CU Colo Ballroom - West 50 5 115 0.06 2305 0.8 893 880 4000 880 4000 FCU Colo Ballroom - East 50 5 106 0.06 2110 0.8 818 840 4000 840 4000 FCU Board Rm 50 5 26 0.06 516 0.8 200 200 800 200 800 FCU Lobby 30 7.5 1 0.06 21 0.8 7 184 800 184 800 FCU Conf Rm 50 5 49 0.06 985 0.8 382 384 1600 384 1600 ***Lobby: OA reduced due to operable openings (6'-8"x6' Door) providing 40 sf of opening . The 40 sf of opening provides natural ventilation for 1000 sf. The space is 1021 sf . The outside air quantity is based on IMC, Section 403 Table 403.3. Natural Ventilation is based on IMC, Chapter 402. The Minimum openable area to the outdoors shall be 4% of the floor area being ventilated. PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 5/15/20181:10:17PMVAILMARRIOTT715WLionsheadCir.Vail,CO8165716-106-00 arv arv 09/14/18 COLORADO BALLROOM MODIFICATIONS arv 11/19/2018 8 11/19/18 CONF RM 234 As indicated EQUIPMENT SCHEDULES M1.0.1 DN DN MOUNTAIN VIEW 225 CO BALLROOM PRE-FUNCTION 221 KITCHEN 227 CHEF 228 ROOM SERVICE 229 BALLROOM STORAGE 02 217 COLORADO BALLROOM 215 B.O.H. CORRIDOR 207 B.O.H. CORRIDOR 207 BALLROOM STORAGE 01 214 CO BALLROOM CORRIDOR 216 .9 .3 0 TYP. TYP. TYP. MENS RR 220 WOMENS RR 219 BALLROOM STORAGE 03 218 BOARD ROOM 233 CONFERENCE 234 CORRIDOR 232 EAGLE BAHN 231 RESTAURANT 235 EXIT EXIT EXIT EXIT EXIT ? ? 136.0 SF STAIR 2 EAST 232B DN UP PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 5/15/20181:10:17PMVAILMARRIOTT715WLionsheadCir.Vail,CO8165716-106-00 arv arv 09/14/18 COLORADO BALLROOM MODIFICATIONS arv 11/19/2018 8 11/19/18 CONF RM 234 1/8" = 1'-0" LEVEL 2 FLOOR PLAN - EAST M2.2.1 1/8" = 1'-0"1 LEVEL 2 FLOOR PLAN - EAST 0'2'8'16'32'4'KEY PLAN - LEVEL 2 EAST FC-1 1234 FC-2 FC-3 1 2 3 4 1 2 3 4 567 DN DN C D E F MOUNTAIN VIEW 225 CO BALLROOM PRE-FUNCTION 221 KITCHEN 227 CHEF 228 ROOM SERVICE 229 BALLROOM STORAGE 02 217 COLORADO BALLROOM 215 B.O.H. CORRIDOR 207 B.O.H. CORRIDOR 207 BALLROOM STORAGE 01 214 CO BALLROOM CORRIDOR 216 .9 .3 C.3 D.6 E.4 E.ZE.7C.6 0 C.7 TYP. TYP. TYP. MENS RR 220 WOMENS RR 219 BALLROOM STORAGE 03 218 BOARD ROOM 233 CONFERENCE 234 CORRIDOR 232 EAGLE BAHN 231 RESTAURANT 235 D.5 EXIT EXIT EXIT EXIT EXIT ? ? 136.0 SF STAIR 2 EAST 232B DN UP PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 5/15/20181:10:17PMVAILMARRIOTT715WLionsheadCir.Vail,CO8165716-106-00 arv arv 09/14/18 COLORADO BALLROOM MODIFICATIONS arv 11/19/2018 8 11/19/18 CONF RM 234 1/8" = 1'-0" LEVEL 2 FLOOR PLAN - EAST M3.2.1 1/8" = 1'-0"1 LEVEL 2 FLOOR PLAN - EAST 0'2'8'16'32'4' KEY PLAN - LEVEL 2 EAST