Loading...
HomeMy WebLinkAboutB18-0272_REV1 approved plans_1539298068 (2).pdfFIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 7 11 NOTE ADDED 6/14/18 7/20/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A0.00 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Cover Sheet Drawing: Cover Sheet Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 7/20/18Date printed: Sturm Residence 5044 Main Gore Drive S Vail,CO Developer: evoDOMUS LLC 3143 W 33rd Street, Cleveland, OH 44109 Contact person: Michelle Kolbe phone: 216.772.2603 email: mk@evodomus.com Owner: Leisa K Sturm Revocable Trust 4552 Meadow DriveUnit 13, Vail,CO 81657 Phone: 312.543.6095 email: lsturm@computervoice.com KEYS TO SYMBOLS WALL SECTION CUT DRAWING NUMBER EARTH/SOIL WALL SECTION WALL SECTION CUT DRAWING NUMBER SCALE: 3/4" or 1-1/2" = 1'-0" POROUS FILL CONCRETE CONCRETE BLOCK BRICK VENEER STONE VENEER DIMENSIONAL LUMBER WOOD BLOCKING PLYWOOD BATT INSULATION RIGID INSULATION GYPSUM BOARD/DRYWALL CLOSED CELL SPRAY FOAM LEVEL/ELEVATION/DATUM DETAIL CUT DRAWING NUMBER DETAIL DETAIL CUT DRAWING NUMBER SCALE: 1-1/2" or 3" = 1'-0" BUILDING SECTION CUT DRAWING NUMBER BUILDING SECTION BUILDING SECTION CUT DRAWING NUMBER SCALE: 1/4" = 1'-0" BUILDING SECTION CUT DRAWING NUMBER INTERIOR ELEVATION INTERIOR ELEVATION VIEW DRAWING NUMBER SCALE:1/2" = 1'-0" ELEV. 1 2 3 Project Description: Two-family residence in District (R). Three-story structure with attached,3-car garage and heated driveway, surface parking and sidewalk. Legal Description: Lot 2 Vail Meadows Filing No. 1 Surveyor: Archibeque Land Consulting, Ltd 115 Broadway - PO Box 3893 Eagle, CO 81631 Contact person: Ted Archibeque Phone: (970)328-6020 email: info@prolandsurvey.com Civil Engineer: Marcin Engineering 130 Ski Hill Road, Suite 235 PO Box 6008 Breckenridge, CO 80424 Contact Person: Tony Vazquez Phone: (970)771-3459 email: tony@marcinengineering.com Local Contractor: SRE Building Associates Vail, CO 81620 Contact Person: Steve Elicker Phone: 970-845-6359 email: steve@srebuilds.com Architect: Robert W. Shearer 5365 West Loveland Rd, Madison, OH, 44057 Contact person: Robert W. Shearer Phone: (216)401-3830 email: rwsheaerer@gmail.com Structural Engineering: Local scope: Isaac A. Lewin Phone: (216) 291-3131 email: iLewin@Lewinandassociates.com Superior Walls: Elijah B. Smith Phone: (919) 559-8275 Modules: David Billingsly Phone: 570-837-0577 Ext. 117 email: david@glencoinc.com Code Information Codes Referenced: 2012 IRC, 2015 IRC1 Design Loads: Wind (302.4): 115 mph Floor: 20DL+40LL Exterior Deck Floor: Snow (301.2.5): Ground: 100 psf 20DL+40LL Soil Bearing Capacity (Geotech): 3000 psf 2012, 2015 IPC 1 Min Fire Separation Distance (302.1): 5'-0" Flood Hazard Area (per FEMA map 08037CO493D): Seismic Design Category (301.2.2): B 2012, 2015 IMC1 2014 NEC, 2017 NEC2 2015 IECC 145 psf Roof: Frost Depth: 48" Energy Code Compliance Method ERI Maximum Energy Rating Index 54 Energy Rating Index as Designed 49 Required Blower door test to meet ERI 3.00 ACH (50) The HVAC System for this project is an engineered system. (Hydronic underfloor-no ductwork) Code Notes See Energy Code Inspection Checklist for items required for IECC compliance. GENERAL NOTES DOCUMENT OWNERSHIP: ALL DRAWINGS AND SPECIFICATIONS PREPARED AS PART OF THIS COMMISSION ARE THE PROPERTY OF evoDOMUS LLC AND WILL NOT BE TRANSFERRED OR USED ON ANY OTHER PROJECT WITHOUT WRITTEN AGREEMENT. GENERAL REQUIREMENTS: WORK PREPARED SHALL COMPLY WITH THE FOLLOWING: (1) PACKAGE CONTAINING BOTH SPECIFICATIONS AND DRAWINGS. (2) APPLICABLE STATE AND LOCAL BUILIDING CODES AND THE RULES AND REGULATIONS OF GOVERNMENTAL AGENCIES AND UTILITY COMPANIES HAVING JURISDICTION OVER THE WORK. INTENT OF THE CONTRACT DOCUMENTS THE INTENT OF THE CONTRACT DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION AND COMPLETION OF THE WORK DESCRIBED OR AS MAY BE AMENDED. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, AND SUPPLIES REQUIRED TO COMPLETE THE WORK ACCORDING TO PLANS, SPECIFICATIONS, AND TERMS OF THE CONTRACT DOCUMENTS. THE APPARENT SILENCE OR OMMISION OF THE CONTRACT DOCUMENTS AS TO ANY DETAIL SHALL BE REGARDED AS MEANING ONLY THE BEST GENERAL PRACTICE IS TO PREVAIL AND ONLY FIRST QUALITY MATERIALS AND WORK ARE TO BE USED. DRAWINGS AND SPECIFICATIONS ARE CONSIDERED OF EQUAL IMPORTANCE. ANY CLARIFICATION REQUIRED BETWEEN THE TWO SHOULD BE ADDRESSED VIA A REQUEST FOR INFORMATION (RFI.) WORKMANSHIP: ALL WORKMANSHIP SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, ORDINANCES, AND ACCEPTABLE BUILDING STANDARDS. THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND FEES. CONSTRUCTION DEBRIS: THE LOCAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EXCESS DIRT AND DEBRIS FROM THE EXCAVATION, DEMOLITION, AND CONSTRUCTION AS REQUIRED; INCLUDING ANY DEBRIS FROM MANUFACTURER. ON-SITE VERIFICATION: THE LOCAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PIOR TO COMMENCING THE WORK. IF A REQUIRED DIMENSION IS NOT SHOWN, CONTACT evoDOMUS FOR MORE INFORMATION. MISCELLANEOUS NOTES: THE BUILDING IS NOT STRUCTURALLY STABLE UNTIL ALL CONNECTIONS, FRAMING, SHEAR WALLS, "X" BRACING, AND EXTERIOR LOAD BEARING MASONRY WALLS ARE COMPLETE AND HAVE ACHIEVED DESIGN STRENGTH. CONTRACTOR IS SOLELY RESPONSIBLE TO MAINTAIN STRUCTURAL STABILITY DURING ERECTION AND CONSTRUCTION. TEMPORARY BRACING SYSTEMS ARE NOT TO BE REMOVED UNTIL STRUCTURAL WORK IS COMPLETE. ALL ANGLED WALLS ON THE FLOOR PLANS ARE AT 45 DEGREE ANGLE; UNLESS NOTED OTHERWISE. FINISHED SQUARE FOOTAGES ARE MEASURED TO THE OUTSIDE OF WALLS. THEY INCLUDE INTERIOR FIREPLACES AND EVERY LOCATION IN WHICH THE FLOOR JOISTS PROJECT FROM THE FOUNDATION. NOT INCLUDED IN SQUARE FOOTAGES: 2-STORY ENTRIES, GARAGES, DECKS, PATIOS, PORCHES, UNFINISHED STORAGE AREAS, BASEMENTS, OR ANY OTHER UNFINISHED AREAS. ENERGY EFFICIENCY STANDARD: THIS HOME IS DESIGNED TO MEET, AT MINIMUM, STANDARDS FOR AN ENERGY STAR HOME AS PUT FORTH BY THE US EPA. CONTRACTOR SHALL FOLLOW ALL GUIDELINES AND CHECKLISTS AS REQUIRED TO MEET THIS STANDARD. COORDINATION OF THE WORK: THE LOCAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE WORK AND THE METHODS OF CONSTRUCTION. INTERPRETATION OF CONTRACT DOCUMENTS: SHOULD DISCREPANCIES OR AMBIGUITIES IN, OR OMISSIONS FROM, THE DRAWINGS OR SPECIFICATIONS BE FOUND, OR INQUIRIES RELATIVE TO THE MEANING OR INTENT OF THE CONTRACT DOCUMENTS ARISE, THEY SHALL BE SUBMITTED TO evoDOMUS LLC AND WILL BE ANSWERED BY ADDENDA. SUCH INSTRUCTIONS AND OTHER ADDENDA ISSUED PRIOR TO THE DATE OF THE SIGNING OF THE AGREEMENT WILL BE CONSIDERED AS PART OF THE CONTRACT DOCUMENTS AND BE BINDING TO THE CONTRACTOR. MANUFACTURER'S PRODUCTS AND FABRICATIONS: ALL MANUFACTURER'S AND FABRICATOR'S PRINTED WARNINGS FOR HANDLING OF HIS PRODUCTS MUST BE STRICTLY OBSERVED. ALSO AS PER LOCAL CODES AND REQUIREMENTS. ALL PRODUCTS AND MATERIALS MUST BE PROVIDED AND INSTALLED IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER. IN THE EVENT OF CONFLICT BETWEEN THE DRAWINGS OR THE SPECIFICATIONS AND THE MANUFACTURER'S RECOMMENDATIONS, NOTIFY evoDOMUS LLC AND OBTAIN CLARIFICATION BEFORE PROCEEDING WITH THE WORK. GUARANTEE: THE LOCAL CONTRACTOR SHALL GUARANTEE THAT ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FOLLOWING COMPLETION OF ALL WORK AND THAT ALL DEFECTS ARISING WITHIN THIS PERIOD OF TIME SHALL BE CORRECTED, REPAIRED, OR REPLACED WITHIN 30 DAYS OF NOTIFICATION OF SUCH DEFECTS BY OWNER OR evoDOMUS LLC. LIABILITY INSURANCE: THE LOCAL CONTRACTOR SHALL PROCURE AND MAINTAIN, AT ITS SOLE EXPENSE, INSURANCE (NAMING evoDOMUS, evoDOMUS AFFILIATES AND, IF REQUIRED, OWNER AND OWNER'S LENDERS, AS ADDITIONAL INSURED) IN SUCH AMOUNTS AND FOR SUCH COVERAGES AS FOLLOWS: (a) COMMERCIAL GENERAL LIABILITY COVERAGE OF $2,000,000 EACH OCCURRENCE (INCLUDING PRODUCTS/COMPLETED OPERATIONS AND PERSONAL AND ADVERTISING INJURY COVERAGES IN THE FOREGOING AMOUNTS), WORKER'S COMPENSATION COVERAGE AS REQUIRED BY STATE LAW (BUT NOT LESS THAN $1,000,000), AND AUTOMOBILE/HIRED AND NON-OWNED LIABILITY WITH A $1,000,000 COMBINED SINGLE LIMIT, OR (b) AS REQUIRED BY THE CONTRACT DOCUMENTS, OR (c) AS REQUIRED BY evoDOMUS'S INSURER, WHICHEVER (a), (b), OR (c) IS HIGHER (AS TO AMOUNT) AND BROADER (AS TO COVERAGE TYPES). Required Special Inspections ITEM Periodic CONCRETE No. Continuous 1 REINFORCING STEEL PLACEMENT X X ONSITE CONCRETE TESTING X CONCRETE APPLICATION TECHNIQUES CONCRETE CURING TEMP. AND TECHNIQUES X WOOD CONSTRUCTION 2 FASTENERS AND CONNECTORS X FRAMING DETAILS X SOILS 3 SITE PREPARATION X X COMPACTED FILL MATERIALS SOIL LOAD BEARING REQUIREMENTS X ENERGY EFFICIENCY4 AIR SEALING X INSULATION INSTALLATION X BLOWER DOOR - PRELIMINARY X BLOWER DOOR - FINAL X DUCT TESTING - PRELIMINARY n/a DUCT TESTING - FINAL n/a HVAC EQUIPMENT AIR BALANCING n/a 1The State of Colorado enforces the 2012 IRC, IPC, and IMC, while the Town of Vail enforces the 2015 versions, therefore both codes apply. If conflicts occur, the more stringent regulation shall apply. 2The State of Colorado enforces the 2017 NEC, while the Town of Vail enforces the 2014 NEC, therefore both codes apply. Where conflicts occur, the more stringent regulation shall apply. Sprinklers and Monitored Fire Alarm System installed per NFPA 72 & VFES Fire alarm installation standards. Zone X Design Information: Occupancy: Use Group: Construction Type Total SF: Stories: R3 Duplex VB 4343 2 STM SHEET INDEX GENERAL Civil Landscaping Plans Architectural Plans Architectural Elevations Architectural Building Sections Wall Sections Interiors Architectural Wall Sections and Details Exterior Details Interior Details Architectural Schedules & Details Structural HVAC Plans Snow Melt System Mechanical Specifications HVAC Schedules Plumbing Plans Plumbing Schedules Electrical Plans Fire Alarm Plans Electrical Schedules Modular Company Shop Drawings ID A0.00 A0.01 A0.02 C-1 C-2 C-3 C-4 L.1 A1.01 A1.02 A1.03 A1.04 A1.15 A1.16 A1.17 A2.01 A2.02 A3.01 A3.02 A3.03 A3.04 A3.05 A3.06 A4.01 A4.02 A4.03 A4.04 A4.10 A4.11 A4.12 A4.13 A4.14 A4.15 A4.16 A4.17 A4.18 A4.19 A4.20 A4.21 A4.90 A5.01 A5.02 A5.03 A5.04 A5.05 A5.06 A5.07 A5.08 A5.09 A5.10 A5.11 A5.12 A5.50 A5.51 A5.52 A5.53 A5.54 A6.01 A6.02 A6.03 A6.04 S.01 S.02 S.03 S.04 M1.1 M1.2 M1.3 M2.0 M3.0 M6.01 P1.01 P1.02 P1.03 P1.04 P1.05 P1.06 P1.07 P1.08 P1.10 P6.01 E1.01 E1.02 E1.03 E1.04 E1.05 E1.06 E2.01 E6.01 E6.02 MC.01 MC.02 MC.03 MC.04 MC.05 MC.06 MC.07 MC.08 MC.09 MC.10 MC.11 MC.12 MC.13 MC.14 MC.15 MC.16 Name Cover Sheet Site Plan w/ Crane Logistics Site Plan Grading Plan Drainage Plan Survey-1 of 2 Survey-2 of 2 Landscape Plan BSMT/Garden Level First Floor Second Floor Roof Plan Reflected Ceiling Plan, Basement Reflected Ceiling Plan, First Floor Reflected Ceiling Plan, Second Floor Elevations East & West Elevations North & South Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Wall Section A Wall Section B Wall Section C Retaining Wall Sections 201 Entry & 204 Dining Interiors 202 Living Room Interior 203 Kitchen & 204 Pantry Interiors 208 WC & 313 Laundry 210 Master 211 Master Bath Interior 212/312/308 Closet Built-ins 306 & 309 Bathrooms 119 Media Room 107 / 112 / 114 Bathrooms APT 105 Living 117 Mudroom Fire Rated Assemblies Foundation, Structural, and Stair Details Entrance Stair Section Entrance Stair Cross Section Exterior Details Exterior Details Exterior Details Exterior Details Exterior Details Exterior Details Exterior Details Exterior Details Exterior Details Interior Details Stair Plans and Sections Enlarged Stair Details Interior Details Tile Details Window Schedule Door Schedule Appliance Schedule Finish Schedules Footing plan Retaining Wall Footing plans BSMT/Garden Level Framing First Floor Framing at Decks HVAC BSMT HVAC First Floor HVAC Second Floor Snow Melt Specifications HVAC Schedules Basement Drain/ Waste Plan First Floor Drain/Waste Plan Second Floor Drain/Waste Plan DWV Isometric Schematic Isometric Basement Plumbing Supply Plan First Level Plumbing Supply Plan Second Floor Plumbing Supply Plan Plumbing Sections Plumbing Schedule BSMT Lighting and Switching Plan BSMT Power Plan First Floor Lighting and Switching Plan First Floor Power Plan Second Floor Lighting and Switching Plan Second Floor Power Plan Fire Alarm Plans Electrical Schedule Electrical Panel Schedule & Riser Diagram Foundation Loading Plan Steel Beam Loading Plan Foundation Structural Plan Foundation Hold Downs Braced Wall Layout 1st Floor Shear Wall Connections 1st Floor Braced Wall Layout - 2nd Floor Roof Structural Plan Shear Wall Connection - 2nd Floor First Story Structural Plan Second Story Structural Plan Roof Structural Plan Section A-A With Details Flitch Beam Details Balcony Wall Connections Balcony Wall Details Issue ID 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Issued Date 6/14/18, 3:28 … - 6/14/18, 3:28 … - - - - - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - - - - - - - - - - - - - 6/14/18, 3:28 … 6/14/18, 3:28 … - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - - 6/14/18, 3:28 … 6/14/18, 3:28 … - - - - - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - - 6/14/18, 3:28 … 6/14/18, 3:28 … - - - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … - 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … 6/14/18, 3:28 … In Mod Package YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES Current SMI on DB 6/29/18 6/29/18 - - - - 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 - 7/9/18 pending 7/9/18 7/9/18 pending 7/9/18 - 7/9/18 - - - - - - 6/29/18 6/29/18 6/29/18 6/29/18 - 6/29/18 6/29/18 7/9/18 6/29/18 - pending 6/29/18 7/9/18 6/29/18 7/6/18 - - 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 - 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 - 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 6/29/18 Current SRE on DB 6/25/18 6/7/18 6/15/18 6/25/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 - 6/7/18 6/7/18 6/7/18 6/26/18 7/9/18 7/9/18 7/9/18 7/9/18 pending 7/9/18 7/9/18 7/9/18 7/9/18 7/9/18 pending 6/7/18 6/25/18 6/26/18 6/26/18 6/26/18 6/25/18 6/25/18 6/25/18 6/25/18 6/25/18 6/25/18 6/25/18 6/7/18 6/7/18 6/15/18 pending 6/7/18 6/7/18 6/7/18 7/9/18 6/26/18 6/26/18 6/26/18 6/8/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 6/7/18 7.11 Project Location 5044 Main Gore Drive S SPRINKLER NOTES: 1. DESIGN PARAMETERS ARE PER NFPA 13 D, 2013. 2. SPRINKLER HEADS ARE CALCULATED FOR A 14'X14' MAXIMUM SPACING. 3. ALL SPRINKLER PIPE IS COPPER. 4. ENTIRE SPRINKLER SYSTEM IS WATER - IT IS THE OWNER AND CONTRACTOR'S RESPONSIBILITY TO PROVIDE INSULATION AND MAINTAIN A CONDITIONED SPACE IN ANY COLD SPACES THE PIPE IS RUNNING. 5. SPRINKLER CONTRACTOR SHALL NOT BE RESPONSIBLE FOR ANY SOFFITING REQUIRED TO RUN PIPES. 6. SPRINKLER CONTRACTOR SHALL NOT BE RESPONSIBLE FOR DRILLING HOLES THROUGH STEEL BEAMS. 7. SPRINKLER CONTRACTOR SHALL NOT BE RESPONSIBLE FOR DRILLING HOLES THROUGH FINISHED CEILING BEAMS. 8. ALL CEILINGS ARE 5/8" DRYWALL - GC SHALL NOTIFY FITTER OF ANY VARIATIONS. 9. PROJECT HAS 8 MODULAR PODS AND THREE SLOPING ROOF AREAS TO BE BUIT OFF SITE. 10. GRUNAU COMPANY TO DO FACTORY INSTALLATION PER APPROVED SPRINKLER PLANS. 11. VAIL FIRE TO INSPECT FACTORY WORK UPON ARRIVAL AT JOB SITE. ANY DRYWALL COVERING PIPE OR HANGERS MAY NEED TO BE REMOVED. ANY PIPE OR HEADS NOT INSTALLED PER PLAN SHALL BE REPLACED/REPAIRED, INCLUDING PIPES NOT HOLDING PRESSURE. ALL PIPING SHALL BE OPEN FOR INSPECTION. 12. A PRESSURE GAUGE TO BE INSTALLED AT ONE HEAD LOCATION PER POD. 13. EACH POD TO BE AIR TESTED TO 100 PSI FOR 24 HOURS AT FACTORY. 14. PRESSURE IN EACH POD TO BE LEFT AT 20 PSI FOR SHIPPING TO SITE. 15. SITE WORK INCLUDES REPLACING GAUGES WITH HEADS AND HYDRO TESTING. Areas: Basement = 2,684 sf First Floor = 2,305 sf Second Floor = 2,375 Total = 7,364 sf 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A0.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Site Plan w/ Crane Logistics Drawing: Site Plan w/ Crane Logistics Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 30'23'-3/4"2 0 ' 2'- 5 1/ 4" 8590 8588 8586 8592 8594 8596 8592 8594 85918590 8588 968590 5 0 4 4 Mai n G o r e D r i v e S DOWNSPOUT8592859385948595 8596 8 5 9 2 8592Rim: 8590.9 30' 4 8 '15'4'4'8' 9'-7" (8599.58') 33'-4 3/4"" (8623.40') 29'-1 1 " (8619.92') 34'-8 3/4" (8624.73') CRANELOCATIONDUMPSTER8'x12'TRAILER STACKB O X S T A G I N G STOCKPILE1":12"1":12"1 1/2":12" 1 1/2":12"1 1/2":12"1/4":12"1/4":12" 1/4":12" 1/4":12" 1/4":12"1/4":12" 1/4":12"BASEMENT FOOTPRINT4' OVERDIG 4' OVERDIGCRANE LOGISTICS FOR DISCUSSION WITH LC, SET CREW AND FACTORY METALUP 3RGross Residential Floor Area Lot Size 22,408 sft Allowable Buildable Area 0.46 x 10,000 = 4,600.0 sf 0.38 x 5000 = 1900.0 sf 0.13 x 7408 = 963.0 sf Total buildable area 7463.0 sf Proposed Buildable Area First Floor Main 2649.5 sf Below Grade Deduction -801.0 sf deduct garage -993.9 sf 854.6 sf Second Floor Main 2,305.3 sf Third Floor Main 2,374.7 sf Total Main 5,534.6 sf Total First Floor Secondary 1,036 sf Total proposed area 6,570.6 sft 3 CAR GARAGE 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A0.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Site Plan Drawing: Site Plan Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 0 5' 10' 20' N 2 A4.04 1A4.0423'-3/4"2 0 ' 2'- 5 1/ 4"32'-8"2A4.043A4 . 0 4 HEATED TERRACE PAVERS ON CONCRETE HEATED STONE STAIRS ON CONCRETE DRIVE WITHIN ROW IS NOT HEATED DRIVE WITHIN ROW IS NOT HEATED HEATED, EXPOSED AGGREGATE CONCRETE DRIVEWAY WITH 4' UNHEATED CONC. PAN AT ROAD GUEST PARKING HEATED, EXPOSED AGGREGATE CONCRETE WITH 4' UNHEATED CONC. PAN AT ROAD HEATED, EXPOSED AGGREGATE CONCRETE SIDEWALK 8590 8588 8586 8592 8594 8596 8592 8594 ROOF DECK ROOF DECK 85918590 8588 968590 5 0 4 4 Mai n G o r e D r i v e S 200 SF SNOW STORAGE 20 ' S E T B A C K LI N E 15' SETBAC K LINE15' SETB ACK LINE15' SETB A C K LI N E EXISTING STRUCTURE DOWNSPOUTSEE CIVIL PLANS FOR LIMITS OF DISTURBANCE, DRAINAGE INFORMATION, AND MORE DETAILED SITE PLAN INFORMATION. SNOW STORAGE 8592859385948595 8596 8 5 9 2 8592Rim: 8590.9 ROOF DECK 4'4'8'32'-8"30'-3/4" (8622.31) 30'-11 3/4" 32'-6 3/4"FOUNDATION LINE BELOWBUILDING LINE BELOW1":12"1":12"1 1 /2":1 2" 1 1/2":12"1 1/2":12"1/4":12"1/4":12" 1/4":12" 1/4":12" 1/4":12"1/4":12" 1 /4":1 2"METAL UP 3RGross Residential Floor Area Lot Size 22,408 sft Allowable Buildable Area 0.46 x 10,000 = 4,600.0 sf 0.38 x 5000 = 1900.0 sf 0.13 x 7408 = 963.0 sf Total buildable area 7463.0 sf Proposed Buildable Area First Floor Main 2649.5 sf Below Grade Deduction -801.0 sf deduct garage -993.9 sf 854.6 sf Second Floor Main 2,305.3 sf Third Floor Main 2,374.7 sf Total Main 5,534.6 sf Total First Floor Secondary 1,036 sf Total proposed area 6,570.6 sft 3 CAR GARAGE FOR ALL WORK IN RIGHT OF WAY: OBTAIN RECOVERABLE ROW PERMIT. CONTACT LEONARD SANDOVAL AT THE TOWN OF VAIL PUBLIC WORKS DEPARTMENT: 970-479-2198 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 05 Basement Layout Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: BSMT/Garden Level Drawing: BSMT/Garden Level Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 122.1 (DR)(t) 113.17'3'106.17'2'-8"106.2110.17' 2'-8" 111.17' 2'-8"115.16'-8" 3' 116.27' 2' 106.2 (TT/FX)(E)120.1 (TTd)120.2 (TT/FX/TT) 116.1 (FX/TT) 111.1 (FX/TT)(E) 107.26'-5" 2'-5 1/2"107.17' 2'-6" 104.1 (DR)(t) 105.1 (TT/FX)105.2 (TT/FX) 106.1 (TT)(t)122.27'-6" 9'122.3 7'-6" 9'122.4 7'-6" 9' 111.2105.17' 3'112.17' 2'-6" 114.17'3'101.1 7'2'-8"119.17' 2'-8" 117.17'2'-4"123.1 6'-8"3'120.17'2'-8"NDWF 0 2' 4' 8' 112.26'-5"2'-5 1/2"3 A5.50 83'-53/8" 43'-23/4" 40'-25/8" 83'-43/4"11'-93/8"43/4"7'-33/4"63/4"17'-113/8"1'-57/8"10'-31/2"8'-67/8" 14'-41/2" 6'-3" 7'-75/8" 18'-73/8" 4'-10" 28'-33/4"101/4" 6'-1" 63/4" 11'-6" 43/4" 12'-27/8" 7'-53/8" 4'-91/2"5'-47/8" 6'-11/8" 61/8"15'-03/4" 7'-33/4" 5'-2" 43/4" 5'-111/4" 43/4" 81/2"4'-43/8" 63/4" 5'-83/8" 1'-07/8" 2'-01/2" 11'-93/4" 16'-91/8"107/8"10'-101/2"43/4"2'-0"43/4"3'-0"43/4"2'-1"2'-21/8"1'-6" 4'-3" 1'-6" 4'-3" 1'-6" 1'-71/2" 3'-6 1/2"43/4" 8'-01/8"3'-43/4"63/4" 3'-35/8"43/4" 2'-0" 107/8" 3/4" 2'-91/2" 3'-111/2" 4'-61/4" 15'-21/8"10'-8" 63/4"15'-53/4"11/2"4'-01/2" 4'-11/2"6'-11" 3'-9"2'-105/8" 43/4" 2'-0" 7'-111/2" 63/4"2'-63/4"3'-23/8" 2'-1" 0.00'(8,592.08') -0'-4.5" (8591.71') -1'-3" (8590.83') TW: 8,594.00' TW: 8,594.00' TW: 8,592.92' TW: 8,592.92' TW: 8,592.92' 03 A3.01 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01CA4.015 A5.10 5 A5.10 C1 C1 1 2 3 4 A4.18 1 2 3 4 A4.18 6 7 8 9 A4.19 5 6 A4.20 2A4.18 POURED IN PLACE REINFORCED CONCRETE STAIR AND RETAINING WALLS WITH #5 @ 16" EW. SEE SPECIFICATIONS AND FINISH SCHEDULES. VERIFY METER CABINET & LOCATION WITH UTILITIES. SUPPLY AND INSTALL FRAMING STRAPS PER SWA BUILDER GUIDELINE BOOKLET FOR MODULAR CONSTRUCTION. SUPPLY AND INSTALL CLOSED TREAD STAIR WITH STONE CLADDING. SEE SECTIONS AND SPECIFICATIONS. FRONT WALL FRAMED BY LC SEE FRAMING PLAN INTERNAL DRAIN FROM ROOF BOILER BOILER UH 1 wall step LINE OF SEPARATION BETWEEN UNITS (1/2 HR FIRE RATED PER IRC 302.3.1) CEILING ABOVE APARTMENT IS REQUIRED TO BE 30 MIN RATED, DESIGNATED AS 1 HR RATED. SOUND INSULATION PER SPECIFICATIONS IN LOCATIONS INDICATED (2) O2 Gen STACKED O2 Gen INTERNAL DRAIN FROM ROOF STEEL LALLY COLUMNS ON CONCRETE PAD FOUNDATIONS OR FOOTERS. POURED IN PLACE REINFORCED CONCRETE RETAINING CURBS. SEE SPECIFICATIONS AND FINISH SCHEDULES. BOILER ROD & SHELFROD & SHELFBUILT-IN CABINETRYWITH DOORSBUILT-IN CABINETRYWITH BENCH & SHELVESBUILT-IN SHELVES KITCHEN LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE HEATED DRIVEWAY DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT HEATED SIDEWALK ENTRY SECONDARY UNIT ENTRY MAIN HOUSE ELEVATOR TANK & CONTROL SOFFIT SLOPE; 1/4"/FT. ROOF DRAINAGE SOFFITSOFFITPEX MANIFOLDSROUGH OPENPROPOSED METERLOCATIONSLOW CABINETRY FOR AV & STORAGEROD &SHELFIN-GROUND HOT TUB HEATED PATIO LUNOS e2 FLAT GARAGE 122 CONC-1 Install:LC A: 783 sq ft MECH RM 102 CONC-2 Install:LC A: 88 sq ft BEDROOM 2 111 CPT-1 Install:LC A: 140 sq ft FOYER 101 S-1 Install:LC A: 179 sq ft STORAGE 103 S-1 Install:LC A: 66 sq ft FOYER 104 S-1 Install:LC A: 60 sq ft HALL 108 EWP-1 Install:LC A: 59 sq ft LAUNDRY 110 S-1 Install:LC A: 10 sq ft BATH 114 S-1 Install:LC A: 55 sq ft HALL 115 S-1 Install:LC A: 62 sq ft MEDIA ROOM 119 CPT-1 Install:LC A: 234 sq ft SAUNA 121 CONC-1 Install:LC A: 42 sq ft MECH RM 113 CONC-2 Install:LC A: 32 sq ft ELEVATOR 100 S-1 Install:LC A: 17 sq ft OFFICE 116 CPT-1 Install:LC A: 150 sq ft PATIO PAVERS A: 260 sq ft BEDROOM 1 106 CPT-1 Install:LC A: 165 sq ftGYM 120 RF-1 Install:LC A: 227 sq ft LIVING 105 EWP Install:LC A: 320 sq ft MUD ROOM 117 S-1 Install:LC A: 53 sq ft STORAGE 123 CONC-1 Install:LC A: 167 sq ft 1A5.0102 A3.02 02 A3.02 05 A3.05 05 A3.05 6 A3.06 6 A3.06 INTERNAL DRAIN FROM ROOF 102.17' 3' 116.1 7'2'-8"38'-0" 6'-83/4"44'-83/4"63/4" 22'-41/2"43/4" 2'-57/8" 15'-51/2"22'-111/4" 63/4" 5'-33/8" 63/4" 13'-105/8" 9'-21/2" 43/4" 30'-73/8" 8'-31/4" 9'-3"71/2"9'-33/8" 9'-51/4" 1'-83/4" 9'-51/4" 1'-83/4" 9'-51/4" 2'-23/8"1'-01/4"44'-103/4"2'-05/8"31/2"3'-05/8"43/4"2'-1"4'-3" 43/4"6'-23/8"43/4"1'-4" 4'-61/4"101/4"10'-8" 6 3/4"15'-53/4" 63/4"4'-0" 63/4"11'-1"5'-83/8" 43/4" 3'-0"63/4"9'-11/8"43/4"4'-3"1 A4.20 SUPPLY AND INSTALL STEEL BEAMS, PER STRUCTURAL. SEE SPECIFICATIONS FOR GARAGE DOORS AND OPENERS. PROVIDE AND INSTALL BUILT IN CABINETRY, BATHROOM VANITIES, TYP FOR ALL EXCEPT KITCHEN 203, PANTRY 205 & LAUNDRY 313 LOCATE TOILET AND WALL SUCH THAT ROUGH PIPING DOES NOT CONFLICT WITH CONCRETE PAD. KEEP AS TIGHT AS POSSIBLE. DHW DHW DHW UP 16R UP 7R DN 4R UP 3R NICHE NICHE HOSE BIB HOSE BIB HOSE BIB HOSE BIB SCUPPER ABOVEUP 2RFLOOR DRAIN STAIR INFO TREADS : 11-1/4" RISERS : 7-1/4" BATH 112 S-1 Install:LC A: 54 sq ft Gross External First Floor (ZONING) A: 2,426 sq ft Gross External Secondary Unit (ZONING) A: 1,034 sq ft BATH 107 S-1 Install:LC A: 39 sq ft A A C C D D E E 6 6 1 5 3 B B 2 2 4 5.05 Mechanical Ventilation required to this room 20 Min self closing door egress egress 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 03 04 HVAC Strategy Change Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Floor Drawing: First Floor Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 203.2(TT/FX/TT) 205.1 (FX/TT) 201.1 (DR/FX)(t) 206.1 (FX) 208.1 (FX) 211.2 (TT FX)(t) 210.17' 3' 211.1 7'3'203.1 (LS)(t)211.26'-11 1/2"2'-11"211A.1 6'-5"2'-11"208.17'2'-8"207.1 7' 2'-6"207.17' 3'-4" 209.1 (TT/FX/FX)(t)203.27'-3 1/2" 6' 0 2' 4' 8'NDW DWF 209.2 (TT)(t)202.2b (FX)(t) 202.2a (TT/FX)(t)202.3a (FX)(t) 202.3b (TT/FX)(t) eD 35.09.03 (TYP) eD 20.03.01, 20.03.02 (TYP) 1 A5.50 1 A5.51 #DrgID #LayID 4 A5.05 2 A5.05 1 A5.53 4 A5.50 A4.13 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01CA4.015 A5.10 5 A5.10 C1 C1 204.1 (LS)(t) 13'-113/8" 13'-113/8" 15'-101/4" 15'-23/4"2'-8" 5'-2" 27'-67/8" 5'-31/8" 9'-23/4"40'-8"7'-10" 13'-113/8" 13'-113/8" 15'-101/4" 15'-23/4" 58'-113/4" 9'-43/4" 2'-0" 8'-101/2" 63/4" 6'-5" 6'-71/8" 63/4" 8'-07/8" 3'-81/8" 4'-43/4"4'-91/2"7'-73/8"3'-43/4" 6'-11" 7'-03/8" 63/8" 11'-113/4" 1'-53/8" 6'-25/8" 5'-91/8" 5'-61/8"43/4"6'-41/8"1'-13/4"41/8" 8'-5"63/4"8'-83/8" 8'-11/2" 1'-11/2"3'-0" 3'-0" 2'-6"48'-03/4"23'-71/8"81/2"23'-91/8"18'-71/8" 5'-0" 11'-51/2" 5'-41/4" 6'-113/8"5'-37/8" 6'-15/8"1'-11/4" 1'-43/4" 2'-21/2" 3'-43/8" 2" 2" 8'-4" 2" 12'-55/8" 61/8" 6'-45/8" 61/8"2'-111/2"43/4" 4'-11/2" 4'-3" 7'-111/8"5/8"18'-71/2" 3'-11" 4'-03/4" 6'-01/4"41/8" 1'-2" 61/8"4'-91/4" 1'-11" EQ EQ 3'-3 3/4" 10 1/4"2'-2 3/4" 3'-11/2"EQ EQ8'-33/8"3'-11/2" 3'-41/2" 4'-61/4" 1'-113/4" 5'-67/8" 7'-31/2" 2'-11/4" 10'-1" 2'-6" 12'-01/2"1'-11/4" 2'-3" 1'-01/8" 9"6'-3" 2'-0"3'-55/8" 2'-93/8"4'-61/2"81/2"2'-0" 8'-51/4"3'-91/4" 12'-21/2"1'-101/4"1'-10" 8'-5" 63/4"8'-03/8"3/4" 2'-91/2" 3'-111/2"W x 7'-5 3/4" H RO (From subfloor) 1'-53/4" 2'-13/4"7'-93/4"5'-2"8'-8" 5'-111/4" 3'-117/8" 4'-81/2" 5'-101/4" 2'-31/4"1'-4" 2'-4"4'-91/8"26'-37/8"18'-71/8" 11'-03/8" 18'-51/4"6'-101/2" 7'-71/8" 4'-01/4" 18'-41/4"2'-57/8" 10'-7" 1'-9" 10'-7" 2'-57/8" 8'-11 1/2"1A5.014 3 2 A4.12 5 6A4.12 1 2 3 4 A4.15 1 2 3 4 A4.14 7 8 9 10 A4.15 2 1 3 4 A4.10 1 2 3 4 A4.11 7 6 5 8 A4.10 4 1 2 3 A4.16 1 2 3 4 A4.14 NON-MODULE CONSTRUCTION MODULE ROOF CONSTRUCTION (FRAMING) INTERNAL DRAIN FROM ROOF PATCH DW AT ALL MATING WALLS (ENTIRE HOUSE) NO MC DW AT THIS WALL, LC PACK-OUT AND ALIGN WITH WINDOW FRAMES NON-MODULE BALCONY CONSTRUCTION NON-MODULE ROOF CONSTRUCTION SEE SECTIONS AND STRUCTURAL DRAWINGS. INTERNAL DRAIN FROM ROOF FRAME & DW SIDES & TOP DRAIN FROM ROOF CANOPY NO MC DW AT THIS WALL, LC PACK-OUT AND ENSURE PLUMB DW INSTALL. PROVIDE RIGID INSULATION WHERE POSSIBLE. SITE INSTALLED THRUST BEAM. SEE MC SHOPSPROVIDE AND INSTALL ALL FRAMING AND CLADDING FOR CHIMNEY. AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS AMERICAN HYDROTECH SYSTEM UNDER DECKING WINDOWABV.; SILLHEIGHT 5'11" BUILT-IN CABINETRYWITH DOORSWINE COOLERBUILT-IN MAKE-UPVANITYELEVATOR CAB 40"x54" CLEAR INTERIOR DRYWALL SHAFT - 3 SIDES; 3/4" PLYWOOD on RAIL SIDE 3' HIGH BUILT-INCHEST OF DRAWERSBUILT-IN CLOSET SYSTEM DN DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT CLEAR GL.MWLUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 FROSTED GL DBL STUD WALL 2x4 & 2x6 TO MARRIAGE WALL STUD HOSE BIB HOSE BIB DOWN SPOUT SCUPPER WALLOVEN COFFEE HOSEBIBLIVING ROOM 202 EWP Install:LC A: 587 sq ft FOYER 201 S-1 Install:LC A: 149 sq ftKITCHEN 203 EWP Install:LC A: 238 sq ft DINING 204 EWP Install:LC A: 225 sq ft PANTRY 205 EWP Install:LC A: 84 sq ft H: 8.42' STAIR 206 S-1 Install:LC A: 34 sq ft HALL 207 S-1 Install:LC A: 43 sq ft WC 208 S-1 Install:LC A: 36 sq ft MASTER BED 210 EWP Install:LC A: 223 sq ft DECK Dasso A: 133 sq ft DECK Dasso A: 59 sq ft Gross External Main Floor (ZONING) A: 2,305 sq ft STEAM SHW 211A T-2 Install:MC A:28 sq ft MASTER BATH 211 S-1 Install:MC A: 196 sq ft DECK Dasso A: 617 sq ft WIC 212 EWP Install:LC A: 65 sq ft 02 A3.02 05 A3.05 6 A3.06 F 202.1 (TT/FX/FX)(t)211.1 (FX)(t)209.3 (LS)(t)A C D E 6 6 1 5 3 B 2 2 4 3 A5.05 58'-113/4" 15'-65/8" 58'-113/4"9'-43/4"31'-5" 9'-3"6'-4"43/4"5'-73/4"1'-0"9'-5" 41/8"77/8"3'-11"5'-0" 43/4"5'-10" 2'-0"43/4"8'-01/4"63/4"4'-73/4"57'-03/8" 1'-113/8" 12'-21/4" 41/8" 14'-05/8" 8'-33/4" 43/4"3'-6" 2'-0"9'-103/8" 11'-71/2"8'-4"9'-103/8" 11'-71/2" 8'-4"#DrgID 5 6 #LayID FLUE TO LOCAL CODE, PER MFG RECOMMENDATIONS. BUILT IN VANITIES, DRAWERS, BATHROOM VANITIES, CABINETRY TYP FOR ALL EXCEPT KITCHEN AND LAUNDRY NON-MODULE LANDING CONSTRUCTION: SEE SECTIONS AND STRUCTURAL DRAWINGS STEPS AND RETAINING WALLS PATCH DRYWALL AT ALL MATING WALLS & CEILINGS (ENTIRE BUILDING) DIRECT VENT GAS FIREPLACE PER SPECIFICATIONS PROVIDE HEAT TAPE FOR ALL DOWNSPOUTS & DRAINS EXTERIOR GAS FIRE FEATURE PER SPECIFICATIONS ACCESS PANEL FOR HYDRONIC HEATING. SEE SPECS. ACCESS PANEL FOR HYDRONIC HEATING. SEE SPECS. UP 18R DN 7R STEAMGENERATORNICHES-01 BENCH w/ STONE SLAB TOPSITE FRAMED, EWPCLAD BENCH w/ STEP SITE FRAMED, EWP CLAD BENCH w/ STEP DN 6R DN 4R STAIR INFO: TREAD : 12" RISER : 6-7/8" UP 3R 5.04 5.04 5.03 5.03 Locking Hot Tub cover req'd 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 03 04 HVAC Strategy Change Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Second Floor Drawing: Second Floor Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 304.1 (TT/FX)(t) 303.3 (FX) 303.2 (FX/FX) 304.2 (FX/TT/FX)(E)(t) 307.1 (FX/TT/FX)(E)(t)307.2 (TT/FX)(t)301.1 (FX/FX)(t) 304.17'2'-8"307.17'2'-8"311.2 (TT FX)(t) 310.1 (TT/FX/FX)(t) 309.17'2'-8"309.26'-5"2'-5 1/2"306.1 7' 2'-8"306.2 6'-5"2'-5 1/2"311A.1 6'-5"2'-11"311.26'-11 1/2"2'-11"310.17' 3' 311.1 7'3'313.1 (FX) 314.1 (FX) 313.17'2'-8"305.17' 2'-6"308.17' 2'-6" 0 2' 4' 8'N310.2 (TTd)(E)(t)2 A5.05 Details 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01C A4.015 A5.10 5 A5.10 C1 C1 1A5.01303.1 (FX/FX)302.1 (LS)(t)13'-113/8" 13'-113/8" 15'-101/4" 15'-2 3/4"50'-83/4"2'-8" 48'-03/4"27'-103/4"15'-101/4" 15'-23/4"3'-0" 9"58'-113/4" 13'-43/8" 1'-17/8" 13'-41/2" 71/8" 8'-33/8" 63/4" 6'-5" 6'-73/4" 61/8" 8'-07/8" 6'-11" 6'-53/8" 6'-51/2" 6'-11" 2'-115/8" 3'-53/8" 3'-81/8" 4'-43/4"4'-23/8" 4'-1" 58'-113/4" 27'-103/4"15'-101/4"15'-23/4" 27'-103/4"15'-101/4"15'-23/4" 7'-93/8" 12'-4" 7'-93/8"15'-101/4"7'-93/4" 6'-71/2"14'-57/8"5'-31/8"1'-43/4"2'-0" 2'-81/4" 2'-53/4"EQ EQ12'-21/2"2'-0"EQ EQ 6'-01/4"41/8"1'-2"4'-91/4" 2'-0" 8'-51/4"3'-91/4" 4'-61/4" 2'-91/2" 3/4" 3'-111/2"W x 7'-5 3/4" H RO (From subfloor)1'-51/4"3'-6"5'-2"12'-57/8" 10'-31/2"6 3/4"4'-43/8" 18'-43/8"8'-31/2" 1'-2" 2'-4"4'-91/8" 11'-11/8" 3'-05/8" 2'-6" 11'-103/4" 4'-43/8" 2'-81/2"3'-0" 3'-2"63/4"3'-0"3'-8" 9'-23/8"1'-17/8" 9'-23/8"3'-8" 5'-111/4"17'-51/4"12'-21/2" 19.86'(8,611.95') 02 A3.02 05 A3.05 6 A3.06 7 8 9 6 A4.13 2 3 4 5 A4.17 6 7 8 9 A4.16 PATCH DRYWALL AT ALL MATING WALLS (ENTIRE BUILDING) LUNOS UNITS FRAMED AND ROUGH WIRED BY MC, INSTALLED AND FINISHED BY LC. TYP FOR ALL IN MODULES PROVIDE AND INSTALL RAILING. SEE SPECS FOR SELECTION. SEE SECTIONS AND DETAIL FOR MORE INFORMATION. PROVIDE AND INSTALL RAILING. SEE SPECS FOR SELECTION. SEE SECTIONS AND DETAIL FOR MORE INFORMATION. TYP FOR ALL BALCONIES. INTERNAL DRAIN FROM ROOF PATCH DRYWALL AT ALL MATING WALLS (ENTIRE BUILDING) PATCH DRYWALL AT ALL MATING WALLS (ENTIRE BUILDING) NO MC DW AT THIS WALL, LC PACK-OUT AND ALIGN WITH WINDOW FRAMES INTERNAL DRAIN FROM ROOF DW TO FRAME SIDES & TOP INTERNAL DRAIN WITH OVERFLOW H2-2 H2-2 CG2-1 NON-MODULE BALCONY CONSTRUCTION T-5 ROD & SHELF ROD & SHELF BUILT-IN CABINETRYWITH DOORS BUILT-IN MAKE-UPVANITYDRYWALL SHAFT - 3 SIDES; 3/4" PLYWOOD on RAIL SIDE BUILT-IN CLOSET SYSTEM BUILT-IN 3' HIGHCHEST OF DRAWERSDOWN SPOUT DOWN SPOUT BUILT-IN LINENW/DOORSWINDOW ABV.; SILL HEIGHT 5'11" LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 CLEAR GL.LUNOS e2 FROSTED GLWD DBL STUD WALL 2x4 & 2x6 BASE 3' AFF w/4' INT CLEARFOYER 301 CPT-? Install:LC A: 144 sq ft GALLERY 302 CPT-? Install:LC A: 187 sq ft BEDROOM 3 304 CPT-? Install:LC A: 201 sq ft BEDROOM 4 307 CPT-? Install:LC A: 201 sq ft MASTER BED 2 310 CPT-? Install:LC A: 223 sq ft WIC 312 CPT-? Install:LC A: 65 sq ftLAUNDRY 313 S-1 Install:MC A: 81 sq ftSTAIR 314 EWP Install:LC A: 39 sq ft Gross External Second Floor (ZONING) A: 2,375 sq ft VOID A: 409 sq ft WIC 308 CPT-? Install:LC A: 20 sq ft WIC 305 CPT-? Install:LC A: 20 sq ft MASTER BATH 311 S-1 Install:MC A: 197 sq ft STEAM SHW 311A T-2 Install:MC A:26 sq ft SHOWER 309A T-2 Install:MC A: 15 sq ft BATH 309 S-1 Install:MC A: 44 sq ft BATH 306 S-1 Install:MC A: 44 sq ft SHOWER 306A T-2 Install:MC A: 15 sq ft 311.1 (FX) 310.3 (FX/FX)(t)A C D E 6 6 1 5 3 B 2 2 4 40'-8"5'-61/8" 43/4" 3'-9" 2'-71/8"1'-13/4"41/8"8'-5"63/4"8'-57/8" 8'-43/4" 1'-03/4"3'-117/8" 4'-6" 6'-03/4" 2'-4"7'-71/4" 7'-71/2"23'-101/4"24'-21/2"11'-6" 12'-41/4"5'-91/4" 6'-23/8" 5'-41/8" 5'-5"73/4"10"11'-115/8"8'-33/4"4 3/4"3'-6" 2'-0" 2'-0"7'-93/8"5'-0" 43/4"6'-0" 1'-10" 43/4"8'-01/4"63/4"4'-73/4" 12'-91/2"3'-0" 1'-6" 3'-0" 11'-75/8" 3'-10" 2'-0" 1'-10" PROVIDE AND INSTALL BUILT IN CLOSET SYSTEM, TYP FOR ALL. NO MC DW AT THIS WALL, LC PACK-OUT AND ENSURE PLUMB DW INSTALL. PROVIDE RIGID INSULATION WHERE POSSIBLE. PROVIDE AND INSTALL DECK FRAMING. SEE FIRST FLOOR PLAN ACCESS PANEL FOR HYDRONIC HEATING. SEE SPECS. ACCESS PANEL FOR HYDRONIC HEATING. SEE SPECS. DN 18R GENERATORDOWN SPOUT LUNOS e2 NICHES-01 BENCH w/ STONE SLAB TOPSTAIR INFO: TREAD : 12" RISER : 6-7/8" DECK Dasso A: 69 sq ft DECK Dasso A: 80 sq ft 5.04 5.04 5.03 5.03 egress egress 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 Reversed Roof Pitch 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Roof Plan Drawing: Roof Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 0 2' 4' 8' 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01CA4.015 A5.10 5 A5.10 C1 C1 1A5.0102 A3.02 05 A3.05 6 A3.06 2'-9" 13'-113/8" 15'-2 3/4" INTERNAL DRAIN WITH OVERFLOW AND HEAT TAPE AMERICAN HYDROTECH FLAT ROOFING SYSTEM. UNDER WOOD DECKING. SEE SPECS FOR MORE INFORMATION. AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS FOR MORE INFORMATION. AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS FOR MORE INFORMATION. AMERICAN HYDROTECH FLAT ROOFING SYSTEM. SEE SPECS FOR MORE INFORMATION. DOWN SPOUT A C D E 6 6 1 5 3 B 2 2 4 8'-0" 4'-0" 4'-0" 8'-0"9'-7" (8599.58')33'-4 3/4"" (8623.40') 29'-11" (8619.92')34'-8 3/4" (8624.73')PROVIDE AND INSTALL EPDM FLAT ROOFING SYSTEM. SEE SPECS FOR MORE INFORMATION. METAL STANDING SEAM ROOFING. SEE EXTERIOR MATERIALS SCHEDULE FOR COLOR AND SPECIFICATION. METAL STANDING SEAM ROOFING. SEE EXTERIOR MATERIALS SCHEDULE FOR COLOR AND SPECIFICATION. METAL STANDING SEAM ROOFING. SEE EXTERIOR MATERIALS SCHEDULE FOR COLOR AND SPECIFICATION. INTERNAL DRAIN WITH OVERFLOW AND HEAT TAPE X GUARD 2.0 SNOW FENCE AS INDICATED, SEE DETAIL 1 / A5.01 PROVIDE AND INSTALL ALL FRAMING AND CLADDING FOR CHIMNEY. CONNECT FLUE PIPE AND PROVIDE AND INSTALL CAP. 1":12" 1":12" 1 1/2":12"1 1/2":12"1 1/2":12"1/4":12" 1/4":12" 1/4":12" 1/4":12" 1/4":12"1/4":12" 1/4":12"METAL UP 3R 5.01 5.01 5.01 Class A rating Req'd for all Roofing assemblies 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.15 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Reflected Ceiling Plan, Basement Drawing: Reflected Ceiling Plan, Basement Scale: 1/4" = 1'-0", 1/16" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: A1 R A1 R A1 R A1 R J1A1 R A1 R A1R G1 A1 R A1R A1R G3 G3A1R A1R A3 R J1A1R A1 R A3R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1R E1E1E1 E1 E1 E1DWF A1 R G2 J1J1A1 R A1 R A1R A1R A1R A1R G2 G2 G2 A1R A1R A1 R A1 R A1 R G3A1R A1R A1 R A1 R F4 CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD 4'-0" 2'-23/8"4'-3" 1'-4"EQ EQ4'-27/8" 2'-0" 2'-0" 6'-0"EQ 3'-0" 5'-4"8'-0" 7'-113/4" EQ EQ EQ2'-6" 2'-6" 3'-0" 6'-1"1'-4"1'-3" 1'-3"3'-6"2'-8"3'-0" 3'-0" 3'-0"3'-0"9'-0"9'-0" 11'-91/4" 11'-91/4" 7'-87/8"EQ EQBATH 114 Ceiling Ht:7.67 BATH 107 Ceiling Ht:7.67 LIVING 105 Ceiling Ht:7.67 FOYER 104 Ceiling Ht:7.67 BEDROOM 1 106 Ceiling Ht:7.67 HALL 108 Ceiling Ht:7.67 BEDROOM 2 111 Ceiling Ht:7.67 GARAGE 122 Ceiling Ht: Varies GYM 120 Ceiling Ht:7.67 BATH 112 Ceiling Ht:7.67 OFFICE 116 Ceiling Ht:8.50 SPRINKLER HEAD, TYP. SEE SPRINKLER DRAWINGS (UNDER SEPERATE COVER.) HALL 115 Ceiling Ht:7.67' MEDIA ROOM 119 Ceiling Ht:8.50 MEDIA ROOM 119 Ceiling Ht:8.92 MUD ROOM 117 Ceiling Ht:8.00 FOYER 101 Ceiling Ht:8.08 MECH RM 113 Ceiling Ht:8.63 MECH RM 102 Ceiling Ht:7.63 ROOF DRAINAGE CLDOORCLIN SAUNA PEX MANIFOLDSELEC & FA PANELS LUNOS e2 A3R G1 A1 R J1 M2 M2 M2 G1 xx xx J1 CO+SD CO+SD G6G6 G7 G7 G8G8 G6 G6G6 G6 xx xxxxxxDWF CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD SCALE: 1/4" = 1'-0" 1 BSMT/Garden Level A1.15 SCALE: 1/16" = 1'-0" 2 BSMT/Garden Level-Dropped Areas A1.15 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.16 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Reflected Ceiling Plan, First Floor Drawing: Reflected Ceiling Plan, First Floor Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: E1 E1 A1 R A1R A1 R E1 A1 R A1 R E1 E1 A1R E1A1R DW DWF A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1 R A1 R A1 R A1 R A1 RA1 R A1 R A1 R A1 R A1R A1R A1R A1 R A1R A1 R J1 J1 A1 R A1 R A1R A1R A1R A1 R A1 RA1 R A1 R A1 R A1R A1 R A1 R A1 R A1R A1R A1 R A1 R A1 R A1 R A1 R F1 F1 A1 R A1 R A1 R A1 R A1R J1J1J1A1R A1R A1R G3G3 A1 R A1 R A1 R E2 E2 E2 F3 A1 R E2 CO+SD CO+SD CO EQ EQEQ EQEQ EQ 1'-6" 1'-6" 1'-11" 1'-11" 111/2" 111/2"11" 4'-6" 1'-6"2'-11/4"3'-1" 2'-67/8" 1'-47/8"3'-51/4" 3'-51/4" 2'-0" 2'-0" 2'-0" 2'-0"2'-0" 2'-0"3'-0" 3'-0"1'-1" 2'-5" 3'-6" 3'-6" 2'-0" 3'-41/4" 3'-6" 3'-6" 6'-41/4" 4'-0" 4'-0"EQ EQ2'-11/2" 2'-11/2"1'-3" 1'-3" 2'-0" 2'-61/4"1'-6" 1'-6"EQ EQ1'-111/2"105/8"2'-3" 2'-3" 4'-31/2" 4'-0" 4'-0" EQ 4'-6"1'-6" 1'-6"10" 6" 3'-0" 1'-61/2"EQ EQEQ EQ1'-6"3'-4" 3'-65/8"2'-0" 2'-0" 2'-1" 3'-4"1'-0"3'-10" 4'-0"1'-8 1/4" 1'-81/4" MASTER BATH 211 Ceiling Ht:8.50 MASTER BED 210 Ceiling Ht:8.50 KITCHEN 203 Ceiling Ht:8.50 FOYER 201 Ceiling Ht:8.50 WC 208 Ceiling Ht:8.50 WIC 212 Ceiling Ht:8.50 DRYWALL SHAFT - 3 SIDES; 3/4" PLYWOOD on RAIL SIDE MWLUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 CL WINDOW, ISLAND, WINE COOLER CL DOOR CL OF MILLWORK CLWALL CL DOORCL OF MILLWORKCLROOMWALLOVEN COFFEE F M2 M2 M2 M2 M2 M2 M1 M1 M1 M1 M1M1M1 A3 R A1 R A1R F2 A1 R A1R A1R A1 R A1R 3'-7" 1'-3"3'-6" 3'-6" 1'-10" 2'-6" 4'-0" 4'-0" SCALE: 1/4" = 1'-0" 1 First Floor A1.16 REFLECTED CEILING NOTES: 1. ALL CEILING HEIGHTS ARE GIVEN FROM THE DESIGNATED FLOOR LEVEL. THIS MAY BE DIFFERENT THAN FINISHED OR SUB FLOOR. SEE BUILDING SECTIONS. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A1.17 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Reflected Ceiling Plan, Second Floor Drawing: Reflected Ceiling Plan, Second Floor Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: A1 R A1R B B A1 R A1 R A1 R A1 R A1R A1R A1 R A1R A1R A1R A1 R A1 R A1R A1R F2F2 A1R A1R A1R A1R A1R A1 R J1 J1 A1 R A1 R A1R J1 J1 A1R G3G3J1J1J1F2 J1 J1 A1 R A1 R A1R A1R A1 R A1 R A1 R A1R A1R A1 R A1R CO+SD CO+SD CO+SD CO+SD CO+SD 1'-3" 111/2" 111/2"1'-5" 1'-5"8"1'-3" 1'-05/8" 1'-73/8" 2'-8" 1'-31/2"3'-0" 2'-8" 1'-8" 1'-0"6" 4'-0" 4'-0" 7"EQ 2'-0" 2'-0" EQ 4'-0" 4'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 3'-1"1'-3" 1'-3" 2'-0" 2'-61/4"1'-6" 1'-6"3'-0" 4'-93/8"1'-6" 1'-6"3'-7"1'-25/8"1'-11"EQ EQ4'-0" 4'-0"4'-0" 4'-0"EQEQ EQ 3'-37/8"2'-1" 4'-0" 2'-1" EQ EQ 4'-0" 4'-0"EQ EQ2'-41/4"EQ EQ 2'-6" 3'-8"1'-107/8"107/8" 2'-3" 2'-3" 1'-0" 3'-6" 3'-6" 2'-0"2'-13/4" 2'-13/4" 8'-13/4"8'-11"1'-0"2'-8" 2'-8" 5'-63/4"1'-4" 3'-0" 3'-0" 1'-4"4'-4" 4'-4"FOYER 301 Ceiling Ht:8.00 MASTER BED 2 310 Ceiling Ht:8.50 MASTER BATH 311 Ceiling Ht:Varies STAIR 314 Ceiling Ht:8.00 BEDROOM 4 307 Ceiling Ht:8.00 BEDROOM 3 304 Ceiling Ht:8.00 GALLERY 302 Ceiling Ht:8.00 BATH 306 Ceiling Ht:8.00 WIC 312 Ceiling Ht:8.50 LAUNDRY 313 Ceiling Ht:8.00 BATH 309 Ceiling Ht:8.00 VOID - Ceiling Ht:8.00 T-5 DRYWALL SHAFT - 3 SIDES; 3/4" PLYWOOD on RAIL SIDE LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 CL CLCL CL CL CLCL CLCLWALL CLCL CLCL OF MILLWORK CL CL WALL CL FIREPLACE CLCL DOORSPACING AS FRAMING ALLOWS PER FRAMING M2 M2 M2 B A3 R A3 R A2 R A2R A2 R A2 R A2R CO+SD E1A3 R A1R A1R A1 R A1 R A1 R A1 R A1R A1R A2 R A1 R LUNOS e2 CL OF MILLWORK SCALE: 1/4" = 1'-0" 1 Second Floor A1.17 REFLECTED CEILING NOTES: 1. ALL CEILING HEIGHTS ARE GIVEN FROM THE DESIGNATED FLOOR LEVEL. THIS MAY BE DIFFERENT THAN FINISHED OR SUB FLOOR. SEE BUILDING SECTIONS. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 04 Reversed Roof Pitch Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A2.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Elevations East & West Drawing: Elevations East & West Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 32'-73/4"32'-10"0" 13'-9"49'-51/8"8'-7"30'-5 3/4" (8622.73) 32'-67/8" (8624.82) 30'-3/4" (8622.31) 30'-113/4" (8623.23) REALSTONE CLADDING REALSTONE CLADDING METAL CLADDING METAL CLADDING WOOD T&G SIDING: THERMORY, CAMBIA OR CEDAR HORIZONTAL RAILING: CABLE, FLAT BAR OR ROD METAL FASCIA HORIZONTAL RAILING: CABLE, FLAT BAR OR ROD CANTILEVERED ROOF STRUCTURE BY MC WATERPROOFING, FINISHES, METAL FASCIA AND SOFFIT BY LC METAL FASCIA, DEPTH PENDING WOOD SOFFIT: THERMORY, CAMBIA OR CEDAR FFL 0.00 = 8591.75' BASEMENT SLAB 121 FFL +19'-9 1/4" 2nd FLOOR FFL +28'-7 3/4" ROOF SHEATHING FFL +8'-11 1/2" 1st FLOOR 40'-113/4"32'-67/8" (8624.48) 30'-113/4" 32'-10 3/4" (8626.48) 0" 13'-9" 12'-51/8" 7"32'-9"INSTALL ALL BASEMENT WINDOWS, DOORS AND SILLS DELIVERED WITH MODULES REALSTONE CLADDING INSTALL ALL WINDOW SILLS DELIVERED WITH MODULES INSTALL ALL WINDOW SILLS DELIVERED WITH MODULES BALCONY INSULATION, MEMBRANE, FASCIA AND RAILING METAL COPING INSTALL LIFT&SLIDE DOOR GLAZING (TYP 0F 4) 111.1 (FX/TT)(E)106.2 (TT/FX)(E) 120.2 (TT/FX/TT) 120.1 (TTd) METAL STANDING SEAM ROOFING METAL FASCIA, DEPTH PENDING HORIZONTAL RAILING: CABLE, FLAT BAR OR ROD METAL CLADDING WOOD SOFFIT: THERMORY, CAMBIA OR CEDAR FFL +19'-9 1/4" 2nd FLOOR FFL +28'-7 3/4" ROOF SHEATHING FFL +8'-11 1/2" 1st FLOOR FFL 0.00 = 8591.75' BASEMENT FLOOR 12 1SIM 5.01 5.01 5.04 5.04 5.04 5.04 WEST ELEVATION 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 Reversed Roof Pitch 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A2.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Elevations North & South Drawing: Elevations North & South Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 15'-3 1/2"10'-10" 32'-10 3/4" (8626.48) 13'-9" 0" 30'-11 3/4"32'-10 3/4"METAL CLADDING INSTALL ALL WINDOW SILLS DELIVERED WITH MODULES INSTALL ALL BASEMENT WINDOWS, DOORS AND SILLS DELIVERED WITH MODULES WOOD T&G SIDING: THERMORY, CAMBIA OR CEDAR CABLE RAILING REALSTONE CLADDING METAL CLADDING METAL FASCIA, DEPTH PENDING REALSTONE CLADDING WOOD SOFFIT: THERMORY, CAMBIA OR CEDAR METAL STANDING SEAM ROOFING HORIZONTAL RAILING: CABLE, FLAT BAR OR ROD REALSTONE CLADDING WOOD T&G SIDING: THERMORY, CAMBIA OR CEDAR EXISTING GRADE EXISTING GRADE 12 1.5 DISTANCE BETWEEN SLAB AND HIGHEST POINT ON ROOFFFL +19'-9 1/4" 2nd FLOOR FFL +28'-7 3/4" ROOF SHEATHING FFL +8'-11 1/2" 1st FLOOR FFL 0.00 = 8591.75' BASEMENT SLAB 69'-37/8"12'-5 1/8" 30'-43/8" EXISTING GRADE REALSTONE CLADDING METAL COPING INSTALL ALL WINDOW SILLS DELIVERED WITH MODULES FFL +19'-9 1/4" 2nd FLOOR FFL +28'-7 3/4" ROOF SHEATHING FFL +8'-11 1/2" 1st FLOOR FFL 0.00 = 8591.75' BASEMENT SLAB 121.5 12 1.5 5.01 5.01 5.01 SOUTH ELEVATION NORTH ELEVATION 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 02 Reversed Roof Pitch Flat Ceilings 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 1 Drawing: Section 1 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: A C D EB 2 A5.01 4 A5.01 4 A5.01 5 A5.04 2 A5.04 3 A5.04 #DrgID #LayID 1 A5.08 -4.71' -1 Top of Footing ±0.00' 1 BSMT/Garden +9.63' 2 First Floor +19.86' 3 Second Floor +29.22' 4 Roof 13'-113/8" 13'-113/8" 15'-101/4" 15'-23/4" 9'-71/2"(8601'-81/2") 19'-103/8"(8611'-113/8") 9'-7"(8601'-8") 0"(8592'-1")7'-8"111/2" 1'-0"8'-6"8'-11"9'-0"0"(8592'-1")8'-6"10'-97/8"30'-113/4"(8623'-3/4")8'-17/8"1'-71/4"8'-51/2"1'-91/2"7'-111/2"0"(8592'-1") 32'-67/8"(8624'-77/8") -91/2"(8591'-31/2")11/2"8'-63/8" 105/8"ROOF + FRAMING BY LC 2" SPRAY FOAM INSULATION EXTERIOR PERMITER DRAIN VENTILATED STANDING SEAM METAL ROOF OVER GRACE ULTRA SELF ADHERED UNDERLAYMENT FOR HIGH TEMPERATURE APPLICATIONS. SEE SPEC SHEET RAISED DECKING ON BUZON PEDESTALS CABLE RAILING CHIMNEY FRAMING AND STONE CLADDING BY LC METAL PARAPET COPING STANDING SEAM METAL ROOF, UNDERLYING MEMBRANE, DRAINAGE BY LC GRAVEL FILL LATERAL DRAINS RADON MITIGATION PIPING GAS FIRE FEATURE WARMBOARD® RADIANT FLOOR HEATING SYSTEM. R-19 INSULATION UNDER WARMBOARD® RADIANT FLOOR HEATING SYSTEM. LC INSTALL UNDER FIRST FLOOR ONLY 1/4" per foot slope 12 1 SIM INSULATION (R-13) OVER SUPERIOR WALLS (R-12.5) RIGID INSULATION8'-71/2" 12"8'-7"1'-77/8"8'-1"1'-31/4" 1'-8"12"8'-7"1'-77/8"8'-1"1'-31/4"-41/2"(8591'-81/2") SUPERIOR WALLS FOUNDATION SYSTEM. SEE SHOP DRAWINGS SLOPE NOT TO EXCEED 1:1 SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. 5.01 5.02 30 min shut off timer req'd at fire pit 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 02 Reversed Roof Pitch Flat Ceilings 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 2 Drawing: Section 2 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 6 5 3 1 3 A5.04 2 A5.50 1 A5.05 1 A5.06 -4.71' -1 Top of Footing (Main House) -4.71' -1 Top of Footing ±0.00' 1 BSMT/Garden Level ±0.00' 1 BSMT/Garden +9.63' 2 First Floor +9.63' 2 First Floor +19.86' 3 Second Floor +19.86' 3 Second Floor +29.22' 4 Roof +29.22' 4 Roof 9'-23/4" 5'-31/8" 27'-67/8" 5'-2" 2'-8" 9'-71/2"12"7'-8" 1'-111/2"8'-7" 1'-77/8" 8'-1"1'-31/4"19'-103/8"24'-03/4"0"1'-0"2'-41/2"30'-3/4" 32'-8" 3'-0"LOWEST POINT OF GRADE DIRECTLY BELOW CORNER OF ROOF OVERHANG (8592') WOOD SIDING SCUPPER TAPERED INSULATION, MEMBRANE AND RAISED THERMORY DECK GALLERY FACE BY LC CABLE RAILING EXTERIOR PERMITER DRAIN GRAVEL FILL POURED IN PLACE FOOTING, SEE STRUCTURAL RADON MITIGATION PIPING SLOPE NOT TO EXCEED 1:1 DINING BEDROOM 4 FOYER OFFICE GYM LIVING ROOM CB2-1 CB2-2 12 1.5 12 1.5 ELEMENTS SHOWN IN SECTION ARE SCHEMATIC ONLY. REFER TO INTERIOR ELEVATIONS AND/OR DETAILS. 2 4 LATERAL DRAINS DS DRAINS SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. 5.02 5.01 5.01 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 3 Drawing: Section 3 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 2 4 5 1 3 6 B A4.02 2 A5.07 1 A5.07 -4.71' of Footing (Main House) -4.71' -1 Top of Footing (Main House) ±0.00' 1 BSMT/Garden Level ±0.00' 1 BSMT/Garden Level +9.63' 2 First Floor +9.63' 2 First Floor +19.86' 3 Second Floor +19.86' 3 Second Floor +29.22' 4 Roof +29.22' 4 Roof 2'-8" 5'-2" 27'-67/8" 5'-31/8" 9'-23/4" 9'-71/2" 19'-103/8" 29'-11" (8619.92) 29'-11" (8619.92) 7'-8"7'-8"4"36'-105/8"RAISED STONE HEATED DRAIN 2 x 6 @ 12 OC FRAMING BY LC STAIR, WALLS RAILING BY LC, SEE SPECS TAPERED INSULATION, MEMBRANE BY LC INFO: ROOF FRAMING INTEGRAL TO MODULE CONSTRUCTION 307.2 (TT/FX)(t)303.1 (FX/FX) 202.1 (TT/FX/FX)(t) BATH WC LAUNDRY ELEVATOR PIT < 14" 12 1.5 12 1.5 ELEVATOR SHAFT SIM ELEMENTS SHOWN IN SECTION ARE SCHEMATIC ONLY. REFER TO INTERIOR ELEVATIONS AND/OR DETAILS.4'-41/2" 4"38'-25/8"EXTERIOR FOOTING DRAIN INTERIOR LATERAL DRAINS DS DRAINS SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 04 Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 4 Drawing: Section 4 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: D C AB 3 A5.06 2 A5.06 1 A5.08 2 A5.08 -4.71' (Main House) ±0.00' BSMT/Garden Level +9.63' 2 First Floor +19.86' Second Floor +29.22' 4 Roof 15'-23/4" 15'-101/4" 13'-113/8" 13'-113/8" 10'-10" (8600.83') 9'-71/2"(8601'-81/2") 19'-103/8"(8611'-113/8") 30'-113/4" 32'-67/8" 30'-53/4" 0"(8592'-1")-41/2"(8591'-81/2") WOOD DECK ON PEDESTALS OVER MEMBRANE ROOFING. SEE SCHEDULES SPECS. GARAGE FRONT WALL FRAMED BY LC BALCONY FRAMED AND FINISHED BY LC SW-3P STANDING SEAM METAL ROOF, UNDERLYING MEMBRANE BY LC BALCONY FRAMED AND FINISHED BY LC WOOD DECK ON PEDESTALS OVER MEMBRANE ROOFING. SEE SCHEDULES FOR SPECS LATERAL DRAIN SYSTEM PERIMETER FOOTING DRAIN (TO DAYLIGHT) TO STORM OUTLET TO DRY WELL RADON MITIGATION SYSTEM SANITARY LINE KITCHEN LIVING 105 MECH RM 102 STORAGE 123 ELECTRICAL PANEL (+/- 15 x 35) FIRE ALARM PANEL (24"x24") ROOFING AND FRAMING BY LC 1/4" per foot slope 121 ELEMENTS SHOWN IN SECTION ARE SCHEMATIC ONLY. REFER TO INTERIOR ELEVATIONS AND/OR DETAILS. E 9'-0" 1'-0"8'-7" 1'-77/8" 8'-1"1'-31/4"8'-01/2" 2'-11/8"8'-51/2" 1'-91/2" 7'-111/2"SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. 5.045.04 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.05 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 5 Drawing: Section 5 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 12 3 6 5 4 1 A5.07 2 A5.07 1 A5.51 2 A5.51 3 A5.51 1 A5.10 -4.71' Top of Footing (Main House) -4.71' -1 Top of Footing (Main House) ±0.00' 1 BSMT/Garden Level ±0.00' 1 BSMT/Garden Level +9.63' 2 First Floor +9.63' 2 First Floor +19.86' 3 Second Floor +19.86' 3 Second Floor +29.22' 4 Roof +29.22' 4 Roof 9'-23/4" 5'-31/8" 27'-67/8" 5'-2" 2'-8" 9'-71/2"(8601'-81/2") 19'-103/8"(8611'-113/8") 30'-53/4"(8622'-63/4") 0"(8592'-1") 32'-67/8"(8624'-77/8") STONE IN GROUT W/ SNOWMELT CONCRETE STAIR CONSTRUCTION W/ STONE STEPS & SNOWMELT CABLE RAILING CUSTOM STAIR BY LC: STRINGERS AND OPEN TREAD STEPS, SEE SPECS. CABLE RAILING TAPERED INSULATION, MEMBRANE METAL PARAPET COPING METAL PARAPET COPING FIBERGLASS BATT INSULATION (R-13) IN SUPERIOR WALL (R-12.5) CAVITIES. TOTAL R VALUE:25.5 PATCH DRYWALL AT STAIRWELL FOR VERTICAL ALIGNMENT LATERAL DRAINS EXTERIOR FOUNDATION DRAINS LIGHTWEIGHT CONCRETE BED SLOPED TO DRAIN 5/8" ZIP SHEATHING AMERICAN HYDROTECH MM6125 WITH PROTECTION LAYER AND HYDRODRAIN. PIP CONCRETE WALL WITH #4 @ 16" EW GRAVEL BACKFILL EXTERIOR FOUNDATION DRAIN RADON MITIGATION PIPING RADON MITIGATION PIPING HEATED DOWNSPOUT 2X6 JOISTS @ 12" OC. HUNG FROM MODULE STRUCTURE. JOIST SPACES FILLED WITH CLOSED CELL FOAM. SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A3.06 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Section 6 Drawing: Section 6 Scale: 1/4" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 6 5 4 3 2 1 1 A5.05 5 A5.05 -4.71' -1 Top of Footing (Main House) -4.71' -1 Top of Footing (Main House) ±0.00' 1 BSMT/Garden Level ±0.00' 1 BSMT/Garden Level +9.63' 2 First Floor +9.63' 2 First Floor +19.86' 3 Second Floor +19.86' 3 Second Floor +29.22' 4 Roof +29.22' 4 Roof DROPPED CEILING, SEE RCPLIVING MASTER BED SIM ELEMENTS SHOWN IN SECTION ARE SCHEMATIC ONLY. REFER TO INTERIOR ELEVATIONS AND/OR DETAILS. SECTION NOTES 1. SEE INTERIOR ELEVATIONS FOR CABINETRY DETAILS AND ELECTRICAL DEVICE PLACEMENT. ITEMS SHOWN IN SECTION ARE SCHEMATIC ONLY. 2. SEE WALL SECTIONS FOR CONSTRUCTION MAKEUP OF WALLS, FLOORS, AND CEILINGS. 3. SEE MC SHOP DRAWINGS FOR ALL STRUCTURAL INFORMATION. SCALE: 1/4" = 1'-0" 1 Section Looking North (incomplete) A3.06 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Wall Section A Drawing: Wall Section A Scale: 1/2" = 1'-0", 3/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. WALL FRAMING; 2x6's @ 24" O.C. WITH 5/8" ZIP SHEATHING (EXT.) AND 5/8" DRYWALL (INT.) W/ 5.5" ROXUL INSULATION (R-23) MEMBRANE ROOFING ON 5/8" ZIP SHEATHING. COVER SHEATHING SLOPED AT 1/4"/FT. FOR DRAINAGE. SEE SPECIFICATIONS FOR MEMBRANE SELECTION. 4" PERFORATED EXTERIOR FOUNDATION DRAIN WRAPPED WITH FILTER FABRIC. SEE CIVIL DRAWINGS. 24" CONCRETE FOOTING W/ (3) #5 CONTINUOUS, BOTTOM, DEPTH VARIES. MIN 48" FROM BOTTOM OF FOOTING TO FINISHED GRADE. GRAVEL BACKFILL WITH NON-WOVEN GEOTEXTILE FILTER FABRIC PER GEOTECH REPORT. UNDER SLAB LATERALS. SEE CIVIL #5 BARS @ 48" O.C. 8" WIDE P.I.P. CONCRETE STEM WALL AT GARAGE WALLS MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL;INSTALL PER MANUF. SPECIFICATIONS. +/-2" SPRAY FOAM INSULATION UNDER HEATED DRIVEWAY. HEATED DRIVE TUBING STEEL BEAM; SEE STRUCTURAL PLANS FOR SIZE (2) 2x6 PT SILL PLATES ON SILL SEALER W/ 1/2" DIA. ANCHOR BOLTS; MIN. 2 PER BD. 12" FROM BOARD END, MAX. 4'-0" O.C. GARAGE SLAB: 4" CONCRETE W 6x6 WWF ON 6 MIL VAPOR BARRIER ON 4" GRAVEL BASE. PROVIDE 1/2" EXPANSION JOINT AT SLAB EDGES, AND PROVIDE RELIEF CUTS AT 10'-0" MAX O.C.; SLOPE AS INDICATED DOUBLE 2x10 RIM JOIST 5/8" DRYWALL WITH SMOOTH FINISH (INT) SEE PLANS AND SPECS WALL FRAMING; 2x4's @ 16" O.C. BETWEEN 5/8" ZIP SHEATHING (INT.) & 5/8" ZIP SHEATHING (EXT.) ROOF FRAMING; 5/8" ZIP SHEATHING (EXT.), GLUED & NAILED, OVER 2x10's @ 12" O.C. W/ 3" CLOSED CELL SPRAY FOAM(R-19.5) AND ROXUL INSULATION(R-23) TOTAL R-VALUE (42.5) DOUBLE 2x6 TOP PLATE REALSTONE® SYSTEMS STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON GALVANIZED METAL LATH WITH MVIS SCRATCH COAT ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. 5/8" DRYWALL. SEE SPECS. BACKER ROD AND SEALANT METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON BUZON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY 2" REALSTONE CAP; SEE SCHEDULE FOR SELECTION 2x NAILING PLATE; SCREWED OR BOLTED TO STEEL BEAM FLANGE KEUKA ITHACA STYLE CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK SCALE: 3/4" = 1'-0" A Garage Wall Section A4.01 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Wall Section B Drawing: Wall Section B Scale: 3/4" = 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: NOTE: FINISHEDFLOORING SCOPE MAYVARY BY MODULE. REFERTO PLANS ANDSPECIFICATIONS FORCLARIFICATION.NOTE: PATCH AND REPAIRDRYWALL AS REQUIREDAFTER MODULE SET.NOTE: FINISHEDFLOORING SCOPE MAYVARY BY MODULE. REFERTO PLANS ANDSPECIFICATIONS FORCLARIFICATION.NOTE: PATCH AND REPAIRDRYWALL AS REQUIREDAFTER MODULE SET.NOTE: CLOSE ANDSECURE ANY/ALL ACCESSOPENINGS IN WALLS/FLOORS/CEILINGS AFTERMODULE SET.NOTE: CLOSE ANDSECURE ANY/ALL ACCESSOPENINGS IN WALLS/FLOORS/CEILINGS AFTERMODULE SET.14" LVL CONTINUOUS HEADER5/8" DRYWALL ON 2x FRAMING(2) LAYERS R-19 INSULATION, UNFACED, +/- 2'WIDERIM JOIST, SEE MC SHOP DRAWINGS.2x6 BOTTOM PLATEBASE; SEE FINISH SCHEDULE AND DETAILWARMBOARD OVER 3/4" SHEATHING (GLUED &SCREWED) OVER 2x10's @ 16" O.C. SOLID 2x10BRACING AT CENTER SPANFINISHED FLOOR; SEE FINISH SCHEDULE AND FLOORPLANS FOR MATERIALS AND SCOPE CLARIFICATIONGASKET AT SEAMPAC ANCHOR-TITE COPING 4.5; INSTALL PERMANUFACTURER'S SPECIFICATIONS14" LVL RIM JOISTROOF; 5/8" ZIP SHEATHING (EXT.), GLUED & NAILED,OVER LVL STRUCTURE (SEE FRAMING DRAWINGS)90 MIL EPDM OVER 5" RIGID INSULATION (R-25 MIN);STAGGER JOINTS HORIZONTALLY & VERTICALLY; TOPLAYER INSULATION TAPERED 1/4"/FT. FOR DRAINAGE;SEE SPECIFICATIONS FOR MEMBRANE SELECTION.HOLES FOR WIRING AND PLUMBING ASSUPPLIED BY SUPERIOR WALLS2x6 PT SILL PLATES ON NEOPRENE SILLGASKET(BETWEEN ALL PLATES); ATTACH WITHBOLTS AND WASHERS AS SUPPLIED BYSUPERIOR WALLS. MIN 2 BOLTS PER BOARD,MAX 4'-0" O.C.DOUBLE 2x12 RIM JOIST2x6 SILL PLATEWOOD BASE; SEE FINISH SCHEDULE AND DETAILFINISHED FLOOR, SEE FINISH SCHEDULEWARMBOARD OVER 3/4" SHEATHING (GLUED &SCREWED) OVER 2x10's @ 16" O.C. SOLID 2x10 BRACINGAT CENTER SPANCLOSED CELL FOAM INSULATION AT RIM JOIST(R-30 MIN)5/8" DRYWALL MAY OCCUR, SEE FINISHSCHEDULEHOLD VENEER 6" MIN UP FROM GRADESTONE VENEER ON MVIS VENEER MORTAR BYLATICRETE. APPLY VENEER MORTAR DIRECTLYTO POWER WASHED SUPERIOR WALLSSURFACE. SEE ELEVATIONS AND SPECS FORSTONE SELECTION.PAC ANCHOR-TITE COPING 4.5; INSTALL PERMANUFACTURER'S SPECIFICATIONSROOF; 5/8" ZIP SHEATHING (EXT.), GLUED &NAILED, OVER 2x12's @ 12" O.C. FILLED W/ 3"CLOSED CELL SPRAY FOAM & 5.5" OF ROXULINSULATION (R-42.5)AMERICAN HYDROTECH 6125 MONOLITHICMEMBRANE ROOFING OVER 1/2" OVERBOARDOVER 2 LAYERS RIGID INSULATION; STAGGERJOINTS HORIZONTALLY & VERTICALLY; TOPLAYER INSULATION TAPERED 1/4"/FT. FORDRAINAGE; (MIN R-VALUE: 25).2x6 WALL; (R-36 MIN); 2x6's @ 16" O.C. BETWEEN 5/8"DRYWALL (INT.) & 5/8" ZIP SHEATHING (EXT.), FILLEDWITH CLOSED CELL FOAM INSULATION (R 36). ALLSHEATHING SEAMS TAPED WITH ZIP TAPE.CLADDING, SEE EXTERIOR FINISH SCHEDULES FORATTACHMENT AND FINISH. FURRING TO ALIGN WITHWALL STUDS.3" CLOSED CELL INSULATION + 5 1/2" ROXULINSULATION. (R-42.5)Xi SUPERIOR WALL FOUNDATION SYSTEM;COMPONENTS INCLUDE CONCRETE STUD,WRAPPED IN EPS INSULATION; VERTICAL #4REBAR INSIDE EACH STUD W/ GALVANIZEDSTEEL FACING. WALL R-VALUE: 12.54" PERFORATED EXTERIOR FOUNDATION DRAINWRAPPED WITH FILTER FABRIC. SEE CIVILDRAWINGS.4" CONCRETE SLAB. W/ 6X6 WWF2" CLOSED CELL SPAY FOAM INSULATION (R-13);INSTALLED IN FIELD24" CONCRETE FOOTING W/ (3) #5CONTINUOUS, BOTTOM. DEPTH VARIES.COMPACTED GRAVEL BACKFILL TO 6" BELOWFINISHED GRADE6" TOPSOIL (BY OWNER) OR OTHER FINISHEDGRADE TREATMENT PER LANDSCAPEDRAWINGSUNDER SLAB LATERALS. SEE CIVIL#5 BARS @ 48" O.C.SUPERIOR WALLS BOLTED TO FOUNDATION.SEE DETAIL.SEE ELEVATIONS ANDCLADDING DETAILS FORFOUNDATION WALLTREATMENT.2x6 WALL; (R-36 MIN); 2x6's @ 16" O.C. BETWEEN 5/8"DRYWALL (INT.) & 5/8" ZIP SHEATHING (EXT.), FILLEDWITH CLOSED CELL FOAM INSULATION (R 36). ALLSHEATHING SEAMS TAPED WITH ZIP TAPE.TOTAL ROOF R VALUE = 67.5MIRADRAIN 6000 DRAINAGE SYSTEM, OREQUAL;INSTALL PER MANUF. SPECIFICATIONS.EARTH BACKFILL PER GEOTECH REPORT.BALLAST TBD BY LCSEE BUILDING SECTIONS SEE BUILDING SECTIONS2x4 CONTINUOUS TOP PLATECEILING: 5/8" DRYWALL; SEE SPECIFICATIONS FORLEVEL OF FINISHPARAPET WALL; 2x4's @ 16" O.C. BETWEEN 5/8" ZIPSHEATHING (EACH SIDE)BASE TIE-IN PER MANUFACTURERS SPECS.2x PARAPET WALL CAP (RIPPED TO WIDTH); FIELDINSTALLED FOR COPINGWRAP MEMBRANE TO FRONT OF WALL. PROVIDE .10 x1" ALUMINUM TERM BAR BY BEST MATERIALS OREQUAL.2x PARAPET WALL CAP (RIPPED TO WIDTH);FIELD INSTALLED FOR COPINGWRAP MEMBRANE TO FRONT OF WALL.PROVIDE .10 x 1" ALUMINUM TERM BAR BYBEST MATERIALS OR EQUAL.5/8" DRYWALL MAY OCCUR; SEE BUILDINGSPECIFIC DRAWINGSWOOD BASE MAY OCCUR; SEE FINISHSCHEDULE AND DETAILSLAB CONTINUES TO INSULATION BETWEENSUPERIOR WALL STUDS.R-13 BATT INSULATIONTOTAL WALL R VALUE:25.5R-19 BATT INSULATIONBELOW WARMBOARD6/4 INTERIOR WINDOW SILL ON 2x2BLOCKING; SEE FINISH SCHEDULE FORSELECTIONDROPPED 5/8" DRYWALLCEILING; CEILINGDRYWALL TO BESUPPORTED BY USGSUSPENSION GRIDSYSTEM OR APPROVEDEQUALFIBERGLASS BATTINSULATION BELOWWARMBOARDAPPROX. FINISH GRADE WITH POSITIVE SLOPE(5%) AWAY FROM DWELLING (6" per 10' MIN.)STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. SCALE: 3/4" = 1'-0"B House Wall SectionA4.02 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 01 Reversed Roof Pitch 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Wall Section C Drawing: Wall Section C Scale: 1/2" = 1'-0", 3/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design.NOTE: FINISHEDFLOORING SCOPE MAYVARY BY MODULE. REFERTO PLANS ANDSPECIFICATIONS FORCLARIFICATION.NOTE: PATCH AND REPAIRDRYWALL AS REQUIREDAFTER MODULE SET.NOTE: FINISHEDFLOORING SCOPE MAYVARY BY MODULE. REFERTO PLANS ANDSPECIFICATIONS FORCLARIFICATION.NOTE: PATCH AND REPAIRDRYWALL AS REQUIREDAFTER MODULE SET.NOTE: CLOSE ANDSECURE ANY/ALL ACCESSOPENINGS IN WALLS/FLOORS/CEILINGS AFTERMODULE SET.NOTE: CLOSE ANDSECURE ANY/ALL ACCESSOPENINGS IN WALLS/FLOORS/CEILINGS AFTERMODULE SET.DOUBLE 2x12 RIM JOIST2x6 SILL PLATEWOOD BASE; SEE FINISH SCHEDULE ANDDETAILFINISHED FLOOR, SEE FINISH SCHEDULEWARMBOARD OVER 3/4" PLYWOOD SUBFLOORON 2x12 JOIST @ 16" O.C. W/ SOLID BRIDGINGAT CENTER OF SPAN.2x6 WALL; (R-36 MIN); 2x6's @ 24" O.C. MAXBETWEEN 5/8" DRYWALL (INT.) & 5/8" ZIPSHEATHING (EXT.), FILLED WITH CLOSED CELLFOAM INSULATION (R 36). ALL SHEATHINGSEAMS TAPED WITH ZIP TAPE.14" LVL CONTINUOUS HEADER5/8" DRYWALL ON 2x FRAMING(2) LAYERS R-19 INSULATION, UNFACED, +/- 2'WIDERIM JOIST, SEE MC SHOP DRAWINGS.2x6 BOTTOM PLATEBASE; SEE FINISH SCHEDULE AND DETAILWARMBOARD OVER 3/4" SHEATHING (GLUED &SCREWED) OVER 2x10's @ 16" O.C. SOLID 2x10BRACING AT CENTER SPANFINISHED FLOOR; SEE FINISH SCHEDULE ANDFLOOR PLANS FOR MATERIALS AND SCOPECLARIFICATIONGASKET AT SEAM5/8" ZIP SHEATHINGCLADDING, SEE EXTERIOR FINISH SCHEDULESFOR ATTACHMENT AND FINISH. FURRING TOALIGN WITH WALL STUDS.STONE VENEER ON MVIS VENEER MORTAR.APPLY VENEER MORTAR DIRECTLY TO POWERWASHED SUPERIOR WALLS SURFACE. SEEELEVATIONS AND SPECS FOR STONESELECTION.CLADDING, SEE EXTERIOR FINISH SCHEDULESFOR ATTACHMENT AND FINISH. FURRING TOALIGN WITH WALL STUDS.2x6 WALL; (R-36 MIN); 2x6's @ 24" O.C. MAXBETWEEN 5/8" DRYWALL (INT.) & 5/8" ZIPSHEATHING (EXT.), FILLED WITH CLOSED CELLFOAM INSULATION (R 36). ALL SHEATHINGSEAMS TAPED WITH ZIP TAPE.THERMORY SOFFITTOTAL ROOF R VALUE = 65.5Xi SUPERIOR WALL FOUNDATION SYSTEM;COMPONENTS INCLUDE CONCRETE STUD,WRAPPED IN EPS INSULATION; VERTICAL #4REBAR INSIDE EACH STUD W/ GALVANIZEDSTEEL FACING. WALL R-VALUE: 12.54" PERFORATED EXTERIOR FOUNDATION DRAINWRAPPED WITH FILTER FABRIC. SEE CIVILDRAWINGS.4" CONCRETE SLAB. SEE BUILDING SPECIFICDRAWINGS FOR SPECIFICATIONS.2" CLOSED CELL SPAY FOAM INSULATION(R-13); INSTALLED IN FIELD24" CONCRETE FOOTING W/ (3) #5CONTINUOUS, BOTTOM. DEPTH VARIES.COMPACTED GRAVEL BACKFILL TO 6" BELOWFINISHED GRADEEMIL PAVER ON 4" CRUSHED STONE; PATIOELEVATION 3" BELOW BOTTOM OF DOORUNDER SLAB LATERALS. SEE CIVIL12" CONCRETE BLOCK, ALL CORES GROUTEDSOLID.#5 BARS @ 48" O.C.MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL;INSTALL PER MANUF. SPECIFICATIONS.3" CLOSED CELL INSULATION (R19.5)LVL RAFTERS PER MC SHOP DRAWINGS,SHAPED AS INDICATEDCOR-A-VENT S400 STRIP VENT IN EACH BAY.1x THERMORY FASCIA TRIM2x6 FASCIA BOARDLOW SIDE EAVE DETAIL PER ROOFINGMANUFACTURER.LOW SLOPE STANDING SEAM METAL ROOFINGPER SPECIFICATIONS ON GRACE ULTRA SELFADHERED UNDERLAYMENT FOR HIGHTEMPERATURE APPLICATIONS.(2) LAYERS 5.5" ROXUL INSULATION (R-46)2x12 RIM JOIST(3) 14" LVL'sSEE BUILDING SECTIONS SEE BUILDING SECTIONS121.56A5.04 2x10 PT SILL PLATES ON NEOPRENE SILLGASKET; ATTACH WITH BOLTS AND WASHERSAS SUPPLIED BY SUPERIOR WALLS. MIN 2BOLTS PER BOARD, MAX 4'-0" O.C.CLOSED CELL FOAM INSULATION AT RIM JOIST(R-30 MIN)5/8" DRYWALL MAY OCCUR, SEE FINISHSCHEDULEWRAP ZIP TAPE TO COVER END OF SHEATHING;PROVIDE AND INSTALL 2" WIDE STRIP OF 5/8"EXTERIOR PLYWOOD TO COVER SILL PLATE.PROVIDE AND INSTALL INSECT PROTECTION ATBOTTOM OF FURRING.4" CONTINUOUS TOP PLATEHOLES FOR WIRING AND PLUMBING ASSUPPLIED BY SUPERIOR WALLS5/8" DRYWALL MAY OCCUR; SEE BUILDINGSPECIFIC DRAWINGSWOOD BASE MAY OCCUR; SEE FINISHSCHEDULE AND DETAILSLAB CONTINUES TO INSULATION BETWEENSUPERIOR WALL STUDS.SUPERIOR WALLS BOLTED TO FOUNDATIONPER SWA DETAILS.R-13 BATT INSULATION SEE ELEVATIONS AND CLADDING DETAILS FORFOUNDATION WALLTREATMENT. R-19 BATT INSULATIONBELOW WARMBOARDFIBERGLASS BATTINSULATION BELOWWARMBOARDBLOCKING AS REQ'DEMIL PAVER PATIO WITH POSITIVE SLOPE(5%) AWAY FROM DWELLING (6" per 10' MIN.); LOCATION OF STEEL BEAM AND WINDOWFROM EDGE OF SUPERIOR WALL 5.01 SCALE: 3/4" = 1'-0"C House Wall SectionA4.03 10/11/18 FIRST FLOOR MODULES A B C D E F G H SECOND FLOOR MODULES RevID ChID Change Name Date 9 10 12 27 Retaining Wall Foundation Revisions 8/22/18 9/6/18 10/2/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Retaining Wall Sections Scale: 3/4" = 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 10/2/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.4'-4" 8"5'-0" 1' to 1'-6" MAX.2'-0" 8" 8" 8" 8" 12" DRAINAGE GRAVEL FILL, WRAPPED IN MIRAFIL NON-WOVEN GEOTEXTILE FILTER FABRIC TOPSOIL UNDISTURBED EARTH CONCRETE FOOTING (2) #5 BARS; TOP AND BOTTOM 4" PVC PERFORATED DRAIN PER CIVIL DRAWINGS SEE SITE PLANS AND SPECIFICATIONS FOR SURFACE AT BOTTOM OF WALL. 1/2" x 45◦ CHAMFER, EACH SIDE #4 BARS @ 16" O.C. (3) #4 BARS; CONT. MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL; INSTALL PER MANUF. SPECIFICATIONS. CONCRETE SURFACE TO BE TEXTURED, COLOR-TINTED PER TOV DESIGN REVIEW GUIDELINES.1'-4" 4'-01/2" 3' TO 4'-0" MAX41/4"3'-01/2"1'-0" 1'-0" 3'-6"7'-6" MAX.5'-6" GRAVEL FILL TOPSOIL SOIL FILL UNDISTURBED EARTH CONCRETE FOOTING #5 x 5'-0" @ 16" O.C. #4 @ 16" OC. CONTINUOUS FOR LENGTH OF WALL 4" PVC PERFORATED DRAIN PER CIVIL DRAWINGS SEE SITE PLANS AND SPECIFICATIONS FOR SURFACE AT BOTTOM OF WALL. HANDRAIL, SEE SPECIFICATIONS. SURFACE MOUNT TO TOP OF WALL PER MANUFACTURER'S RECOMMENDATIONS. 1/2" x 45◦ CHAMFER, EACH SIDE #5 @ 16" OC. VERTICAL #4 @ 16" OC. HORIZONTAL #4 @ 16" EW (2) #4 CONTINUOUS MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL; INSTALL PER MANUF. SPECIFICATIONS. CONCRETE SURFACE TO BE TEXTURED, COLOR-TINTED PER TOV DESIGN REVIEW GUIDELINES. 12" DRAINAGE GRAVEL FILL, WRAPPED IN MIRAFIL NON-WOVEN GEOTEXTILE FILTER FABRIC 1'-4" 4'-01/2" 3' TO 4'-0" MAX41/4"3'-01/2"3'-6" MIN 2'-0"7'-6" MAX.5'-6" 2'-6"+/- GRAVEL FILL TOPSOIL SOIL FILL UNDISTURBED EARTH CONCRETE FOOTING #5 x 5'-0" @ 16" O.C. #4 @ 16" OC. CONTINUOUS FOR LENGTH OF WALL 4" PVC PERFORATED DRAIN PER CIVIL DRAWINGS SEE SITE PLANS AND SPECIFICATIONS FOR SURFACE AT BOTTOM OF WALL. HANDRAIL, SEE SPECIFICATIONS. SURFACE MOUNT TO TOP OF WALL PER MANUFACTURER'S RECOMMENDATIONS. 1/2" x 45◦ CHAMFER, EACH SIDE #5 @ 16" OC. VERTICAL #4 @ 16" OC. HORIZONTAL #4 @ 16" EW (2) #4 CONTINUOUS MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL; INSTALL PER MANUF. SPECIFICATIONS. CONCRETE SURFACE TO BE TEXTURED, COLOR-TINTED PER TOV DESIGN REVIEW GUIDELINES. 12" DRAINAGE GRAVEL FILL, WRAPPED IN MIRAFIL NON-WOVEN GEOTEXTILE FILTER FABRIC PROPERTY LINE 1'-4" 4'-01/2" 4' TO 6'-0" MAX41/4"3'-01/2"5'-0" 2'-0"10'-0" MAX.7'-0" TOPSOIL HANDRAIL, SEE SPECIFICATIONS. SURFACE MOUNT TO TOP OF WALL PER MANUFACTURER'S RECOMMENDATIONS. 1/2" x 45◦ CHAMFER, EACH SIDE 12" DRAINAGE GRAVEL FILL, WRAPPED IN MIRAFIL NON-WOVEN GEOTEXTILE FILTER FABRIC MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL; INSTALL PER MANUF. SPECIFICATIONS. CONCRETE SURFACE TO BE TEXTURED, COLOR-TINTED PER TOV DESIGN REVIEW GUIDELINES. (2) #4 CONTINUOUS SOIL FILL UNDISTURBED EARTH CONCRETE FOOTING #6 x 6'-0" @ 12" O.C. #4 @ 16" OC. CONTINUOUS FOR LENGTH OF WALL 4" PVC PERFORATED DRAIN PER CIVIL DRAWINGS SEE CIVIL PLANS AND SPECIFICATIONS FOR SURFACE AT BOTTOM OF WALL. #6 @ 12" OC. VERTICAL #4 @ 16" OC. HORIZONTAL #4 @ 16" EW 10'-11"2'-10"7'-5" 6'-11" 18'-01/4"4"2'-5" 8" 8" 9'-7" 8" 7'-91/4" 10'-51/4"8"2'-0" #4 @ 12" O.C. DOWELS EACH WALL #4 @ 12" O.C. EW #4 @ 16" OC. HORIZONTAL 6X6 W2.9XW2.9 WWF HOT TUB UNIT STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 12.27 SCALE: 3/4" = 1'-0" 1 1'-6" Max Retaining Wall A4.04 SCALE: 3/4" = 1'-0" 2 4'-0" Max Retaining Wall A4.04 SCALE: 3/4" = 1'-0" 3 4'-0" Max Retaining Wall With Reversed Footing A4.04 SCALE: 3/4" = 1'-0" 4 6'-0" Max Retaining Wall With Reversed Footing A4.04 SCALE: 1/2" = 1'-0" 5 Hot tub section detail A4.04 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.12 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: 203 Kitchen & 204 Pantry Interiors Drawing: 203 Kitchen & 204 Pantry Interiors Scale: 1/2" = 1'-0", 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 1'-13/4" 2'-0" 3'-6" 2'-0" 1'-13/4"11/4"10'-0"2'-11/2" 3'-4" 3'-6" 3'-41/2"2'-6"2" 1'-8" 1'-8" 1'-8"2"2'-6" 2'-6" 2'-6" 2" 1'-3" 2'-0" 3'-6" 2'-0" 1'-3"2" 11/4"2'-3" 1'-3" 3'-3" 27/8"2"2'-0" 2'-0"2" 2'-1" 10'-1" 2'-6" 21/2" 2'-0" 2'-0" 1'-0" 2'-0" 3'-7" 2'-0" 41/8" 4'-47/8" 113/4" 2" 2'-6" 1'-8" 2'-6" 1'-8" 2"3'-11" 2'-81/2"11/2"5'-73/4" 1'-0" 9'-5" 1'-0" 6'-4"43/4"2'-2" 2'-41/2"5'-67/8"7'-31/8" 2" 2'-21/2" 8'-8" 12'-10"5/8" 31/2" 71/4"5/8"1" 23'-0" 81/2"2'-0"3'-81/2"1'-0" 2" 2'-0" 2'-0" 2'-0" 2'-0" 11/4" 27/8"5'-0"FRONTS FLUSH W/ SIDE PANELS (TYP ALL)STUD WALL, SINGLE SIDED DWCOUNTERTOP COUNTERTOPVENTILATION GAP AT REAR OF CABINETSBOX DEPTH BOX DEPTH BOX DEPTH DRAIN PIPES & FRAMING. MUST LOCATE WINE COOLER COOLING UNIT IN BSMT OR CLOSET CABINET Pantry Broom Closet BOX DEPTH KITCHEN PANTRY BOX DEPTH2x6 EXT FRAMING2x8 EXTFRAMINGBOX DEPTH BOX DEPTHMODULEMARRIAGE LINE CL WINDOW & ISLAND DWDW WALL OVEN MICROWAVECOFFEE MACHINEFRIDGE FRIDGEINDUCT.COOKTOPWINE COOLERCLG FLUSH HOOD8"42 6 5 3 7 1'-13/4"4" 2'-11/4"51/4" 11/4"1'-51/2" 3'-3" 91/4"3'-6" (TYP)1'-73/4"1'-111/4"2'-91/2"1'-73/4"2'-113/4"2'-101/2"5'-0"2'-3" TBC7'-81/4" 91/4"1'-11/4" 1'-0"51/4"5'-0" SS TRIM Oil Pull-out Cutlery Peg board for dishes Pots and pans Pots and pansTowels and potholders Utensils Spice pull-out Pots and pans Pots and pans Trays Platters Glasses Mugs SS TRIM MINMOUNTDISTANCECONCEALED LIGHTING COFFEE VENT COFFEE VENT (MFG MINIMUM)CLEARCLEARCLEARCL OUTLET CL OVENPLUMBINGAPPLIANCE SELECTIONS WALL OVEN MICROWAVE COFFEE CLG FLUSH HOOD GAS COOKTOP INDUCT. COOKTOP Pantry Broom Closet ALIGNMENT VOID VENTILATION THROUGH BULKHEAD BOX DEPTH NO CABINET BACK TO ENABLE ACCESS TO OVEN PLUMBING CL OVEN PLUMBING8" HOOD DUCT SEE APPLIANCE SPECFRONT HIGHER THAN FRIDGEFRONT HIGHER THAN FRIDGE FRIDGE FRIDGE COFFEE 6" 6"CUSTOM GLASS WINE COOLER DOORS- FULLY GASKETED. (2) TRASH PULL-OUT PANELS TO MATCH BASE FRONTS 5 EQ SECTIONS WATERFALL ISLAND w/ MITERED EDGES DW DW (2) TRASH PULL-OUT COUNTERTOP w/ MITERED EDGE BOX DEPTH DOG FOOD PULLOUT DOG FOOD CANS CONCEALED LIGHTING 3/4" 1/4"1'-0" 1"3/4"9" RUN WIRE IN REAR CORNER OF CABINET TO TRANSFORMER LOCATED AGAINST BACK WALL OF TOPMOST SHELF HARDWARE PER SPEC 3/4" PLYWOOD, FRAMELESS CONSTRUCTION SCALE: 1/2" = 1'-0" 1 KITCHEN PLAN DETAIL A4.12 SCALE: 1/2" = 1'-0" 2 KITCHEN 203S A4.12 SCALE: 1/2" = 1'-0" 3 KITCHEN 203E A4.12 SCALE: 1/2" = 1'-0" 4 KITCHEN 203N A4.12 SCALE: 1/2" = 1'-0" 5 PANTRY205W A4.12 SCALE: 1/2" = 1'-0" 6 PANTRY205N A4.12 SCALE: 1 1/2"= 1'-0" 7 Wall cabinet UC lighting A4.12 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.13 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: 208 WC & 313 Laundry Drawing: 208 WC & 313 Laundry Scale: 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions:6/25/18Date printed: DW RETURN, NO SILL 2cm QUARTZ OVER 3/4" PLYWOOD BOX & STEEL SUPPORTS EQ EQ 1'-91/4"3/4" 1'-81/4" 3/4"1'-93/4"1'-6"5" 5'-11/4" 5" 4" 4"2'-6"FLOOR TILE ORIGIN AT DW CORNER ELECTRICALPANELTRANSITION PROFILE MIN CLEAR1 24 208 A4.XX 3 CONCEALED LIGHTINGELECTRICAL PANEL (3) RETRACT. CLOTHESLINES LUNOS eGO GAS WATER WATER DUCT GAS DRYERWASHER 4'-0" 1'-111/4" 2'-0" 1'-0"1'-8"11/4"1'-6" 1'-6" 3'-0"2"6'-31/4"2'-11/2" 3" 4" 4" 3" X 10" HVAC GRILLE IN FLOOR PER MECHANICAL DRAWINGS. FLOOR & WALL TILE ORIGIN BOX DEPTH BOX DEPTH PLUMBING WALLELECTRICALPANELGAS DRYER WASHER 7 8 6 9 SCALE: 1/2" = 1'-0" 1 WC 208W A4.13 SCALE: 1/2" = 1'-0" 2 WC 208N A4.13 SCALE: 1/2" = 1'-0" 3 WC 208E A4.13 SCALE: 1/2" = 1'-0" 4 WC 208S A4.13 SCALE: 1/2" = 1'-0" 5 WC 208 PLAN DETAIL A4.13 SCALE: 1/2" = 1'-0" 6 LAUNDRY 313S A4.13 SCALE: 1/2" = 1'-0" 7 LAUNDRY 313W A4.13 SCALE: 1/2" = 1'-0" 8 LAUNDRY 313N A4.13 SCALE: 1/2" = 1'-0" 9 LAUNDRY 313E A4.13 SCALE: 1/2" = 1'-0" 10 Laundry Plan Detail A4.13 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.15 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: 211 Master Bath Interior Drawing: 211 Master Bath Interior Scale: 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 8'-33/4" P-3 P-3 P-3 P-1 P-2 T-5 T-5 P-2 CT-1 CT-1 S-1 T-5 TOP OF WB TOP OF FF TOP OF SHEATH 1'-03/4" 1'-03/4"5"11/4"2'-51/2"P-1 P-2 CT-1 S-1 P-2 P-2 CT-1 P-2 S-1 MAKE-UP TABLE DRESSER TOP OF WB TOP OF FF TOP OF SHEATH FREE-STANDING MIRROR 1/2" 10"6'-0"S-1 P-1 P-2 CT-1 S-1 WIRE TO CT DOCKET P-2 TOP OF WB TOP OF FF TOP OF SHEATH2'-113/4"P-3 P-3 P-3 P-3 P-3 P-3 5 1/4"1'-111/4" 6"11/4"2'-113/4"EQ EQ 3'-33/8"7/8"3/4"31/2"53/4"S-1 T-1 P-1 P-2T-1 FLOOR TILE ORIGIN ROUGH OPENTOP OF WB TOP OF FF TOP OF SHEATH TOP OF DW 7/8"3/4" 1'-105/8"IN-WALL TOILET CARRIERS-1 STEAM SHOWER GENERATOR LINEN CLOSET 1'-41/8"71/2"1'-111/2" S-1 IN-WALL CARRIERS 5/8"21/4"1'-61/2" 1'-61/2" 1'-61/2"21/4" 2'-0"103/4" 3'-0" 5'-11/8"3'-0" 2'-25/8"1/4"2"3'-5"11/2" 2'-11/2" 11/2" 1/4"11/2" 1'-9" 8'-33/4"43/4"3'-6" 3/4" 1'-81/2"5'-0"43/4"6'-0"1/4"11/2"2'-81/2"2'-81/2"2'-81/2"11/2"1/4"8'-5"5'-111/2"4'-71/2"1'-11" 3'-23/8" 2'-43/4" 31/2" 4'-3" 1'-3" 31/2"63/4" 7'-63/4"5/8"5'-0"5/8" 51/2" 5/8" 5/8" 31/2" 1'-101/2"3cm STONE SLAB w/ EASED, POLISHED EDGESWINDOW SILL BELOWTRANSITION PROFILETRANSITION PROFILE NICHEFLOOR TILE ORIGIN DBL STUD WALL 2x4 & 2x6 ROUGH OPEN BOX DEPTH CT DEPTH 1'-4" 2'-4" 1'-4"1/4"11/2" 1'-3" 11/2" 5'-31/4"11/2" 1'-3" 11/2"1/4" 11/2"1'-61/4"5'-11/2" 1'-61/4" 11/2" 2 35 4 9 1012 11 6 7 5 8 STEAMSHOWERGENERATORBELOWSCALE: 1/2" = 1'-0" 1 M. BATH 211W A4.15 SCALE: 1/2" = 1'-0" 2 M. BATH 211N A4.15 SCALE: 1/2" = 1'-0" 3 M. BATH 211E A4.15 SCALE: 1/2" = 1'-0" 4 M. BATH 211S A4.15 SCALE: 1/2" = 1'-0" 5 M. BATH 211N A4.15 SCALE: 1/2" = 1'-0" 6 M. BATH 211E A4.15 SCALE: 1/2" = 1'-0" 7 MASTER BATH 211W A4.15 SCALE: 1/2" = 1'-0" 8 MASTER BATH 211N A4.15 SCALE: 1/2" = 1'-0" 9 MASTER BATH 211E A4.15 SCALE: 1/2" = 1'-0" 10 MASTER BATH 211S A4.15 SCALE: 1/2" = 1'-0" 11 M. BATH PLAN DETAIL A4.15 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.17 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: 306 & 309 Bathrooms Drawing: 306 & 309 Bathrooms Scale: 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: EQ EQ10"11/2" 1'-21/4" 3'-73/4" 1'-21/4" 11/2"FLOOR TILE ORIGIN TRANSITION PROFILE BOX DEPTH SLOPE SLOPE SLOPEROUGH OPEN11/4"1'-81/2" 2 35 306 4 7 306 6 2 35 309 SIM 4 7 309 SIM 6ROUGH OPEN306 BATH ELEVATION 2 FLOOR TILE ORIGIN FINISHED BACK/SIDE PANELS, PLATFORM & TOEKICK FLOOR TILE ORIGIN SCALE: 1/2" = 1'-0" 1 Laundry Plan Detail A4.17 SCALE: 1/2" = 1'-0" 2 SHOWER 306AW A4.17 SCALE: 1/2" = 1'-0" 3 SHOWER 306AN A4.17 SCALE: 1/2" = 1'-0" 4 BATH 306E A4.17 SCALE: 1/2" = 1'-0" 5 SHOWER 306AS A4.17 SCALE: 1/2" = 1'-0" 6 BATH 306E A4.17 SCALE: 1/2" = 1'-0" 7 SHOWER 306AW A4.17 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A4.90 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Fire Rated Assemblies Drawing: Fire Rated Assemblies Scale: 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: UL U407 or GA WP 0700 - Featured Interior Partitions -Wood Stud (Load- bearing) Fire Rating 0.5 hour System Thickness 4-3/4" Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically USG Sheetrock® Brand UltraLight Panels Firecode30® - 5/8" (UL Type FC30) Wood Studs - 2 in. x 4 in. wood studs spaced max. 16 in. OC Gypsum Board - 5/8 in. thick gypsum board applied horizontally or vertically USG Sheetrock® Brand UltraLight Panels Firecode30® - 5/8" (UL Type FC30) Stud size is minimum unless otherwise stated in design. For the most up-to-date information refer to the UL Fire resistance directory U407 ! · Assembly Options UL L501 Wood Dimensional Lumber Fire Rating Unrestrained‐1 hour System Thickness N/A [CK-6412-7 based on 1-1/4" nom. wood 7oor] Floor Underlayment - Min. 3/4 in. (19 mm) thick, min. compressive strength 1800 psi USG Levelrock® Brand Floor Underlayment 2500 (UL Type LRK) USG Levelrock® Brand Floor Underlayment 4500 (UL Type HSLRK) USG Levelrock® Brand Floor Underlayment 3500 (UL Type LRK) Sub7oor - 15/32 in. (12 mm) thick plywood underlayment Structural Members - Nom. 2 in. (51 mm) by 10 in. (254 mm) max. 16 in. (406 mm) OC Gypsum Board - 5/8 in. (16 mm) thick gypsum board USG Sheetrock® Brand AR Firecode® X Panels - 5/8" (16 mm) (UL Type AR) USG Sheetrock® Brand UltraLight Panels Firecode® X - 5/8" (16 mm) (UL Type ULIX) USG Sheetrock® Brand Firecode® X Panels - 5/8" (16 mm) (UL Type SCX) USG Sheetrock® Brand Foil-Backed Gypsum Panels (Regular and Firecode® X) - 1/2" or 5/8" (12 mm or 16 mm) (UL Type SCX) USG Sheetrock® Brand Glass-Mat Panels Mold Tough® AR Firecode® X - 5/8" (16 mm) (UL Type AR) USG Sheetrock® Brand Glass-Mat Panels Mold Tough® VHI Firecode® X - 5/8" (16 mm) (UL Type AR) USG Sheetrock® Brand Gypsum Base Imperial®, Firecode® X - 1/2" or 5/8" (12 mm or 16 mm) (UL Type IP-X2) USG Sheetrock® Brand Gypsum Base Imperial®, Firecode® X - 5/8" (16 mm) (UL Type IP-X1) USG Sheetrock® Brand MH Gypsum Base Board Firecode® C - 5/8" (16 mm) (UL Type C) USG Sheetrock® Brand MH Gypsum Base Board Firecode® X - 5/8" (16 mm) (UL Type SCX) USG Sheetrock® Brand Mold Tough® AR Firecode® X Panels - 5/8" (16 mm) (UL Type AR) USG Sheetrock® Brand Mold Tough® Firecode® C Panels - 1/2" or 5/8" (12 mm or 16 mm) (UL Type C) USG Sheetrock® Brand Mold Tough® Firecode® X Panels - 5/8" (16 mm) (UL Type SCX) USG Sheetrock® Brand Mold Tough® VHI Firecode® X Panels - 5/8" (16 mm) (UL Type AR) USG Sheetrock® Brand Firecode® C Panels - 1/2" or 5/8" (12 mm or 16 mm) (UL Type C) Stud size is minimum unless otherwise stated in design. For the most up-to-date information refer to the UL Fire resistance directory L501 ! · Assembly Options MIN **(SEE NOTES BELOW) ** 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Foundation, Structural, and Stair Details Scale: 3/4" = 1'-0", 1 1/2"= 1'-0", 1/2" = 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 7/20/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.1'-0" 1'-0"2'-0" MIN 2'-0" OVERLAP VARIES, SEE FOOTING PLAN(3) #5 DOWELS (3) #5 BARS, CONTINUOUS, BOTTOM 41/2"4"MIN EMBEDMIRADRAIN OR EQUAL 1/2" SIMPSON TITEN HD @ 48" OC MAX BP 1/2-3 SIMPSON BEARING PLATE SHIM UNDER STUDS WHERE REQUIRED. FILL JOINT WITH 5000 PSI NON SHRINK, NON METALLIC GROUT. STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 5/8"31/2" 63/4" 101/4" LINE OF CONCRETE WALL EDGE FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS (1/2" SHIM SPACE ALL SIDES) INSTALLATION BRACKET SUPPLIED BY WINDOW MANUFACTURER TRIPLE PANE WD/ALUM. WINDOW. SEE WINDOW SCHEDULE. TRIPLE PANE WD/ALUM WINDOWS. SEE WINDOW SCHEDULE. 1x WOOD TRIM, RIPPED AS REQUIRED. METAL FLASHING INTERIORINTERIORTYPICAL JAMB HEAD SILL EXTERIOREXTERIOR51/8" 31/8" 2" DRYWALL RETURNS TO WINDOW FRAME, TOP AND SIDES. CORNER BEAD FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS (1/2" SHIM SPACE ALL SIDES) TEAR AWAY BEAD AT FRAME DRYWALL MAY OCCUR, SEE FINISH SCHEDULE. FOUNDATION WALL MOUNTING BRACKETS SUPPLIED BY WINDOW MANUFACTURER 30mm SILL EXTENSION BY WINDOW MANUFACTURER; PART OF WINDOW CONCRETE HEADER BEAM. SEE SWA SHOP DRAWINGS. FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS. PT 2x BUCK INSTALLED AT SWA FACTORY. (ALL FOUR SIDES) 6/4 INTERIOR WINDOW SILL. SEE FINISH SCHEDULE FOR SELECTION WRAP SECOND LAYER OF BITUMINOUS TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. WRAP 6" BITUMINOUS TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. WRAP SECOND LAYER OF BITUMINOUS TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. WRAP 6" BITUMINOUS TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. 1 1/2" CONTINUOUS BLOCKING AT SILL WRAP 6" BITUMINOUS TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. WRAP SECOND LAYER OF BITUMINOUS TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. 6/4 INTERIOR WINDOW SILL. SEE FINISH SCHEDULE FOR SELECTION PT 2x BUCK INSTALLED AT SWA FACTORY. (ALL FOUR SIDES) PT 2x BUCK INSTALLED AT SWA FACTORY. (ALL FOUR SIDES) POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. INSTALL WINDOW SILL; SUPPLIED BY MANUFACTURER POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION INSTALL WINDOW SILL; SUPPLIED BY MANUFACTURER SCALE: 3/4" = 1'-0" 1 STEPPED FOOTING DETAIL A5.01 SCALE: 1 1/2"= 1'-0" 2 Superior Walls Attachment Detail A5.01 SCALE: 3" = 1'-0" 4 Window HJS A5.01 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Entrance Stair Section Drawing: Entrance Stair Section Scale: 3/4" = 1'-0", 1 1/2"= 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/26/18 Date printed: 2 A5.02 1 A5.07 #4 VERTICALS @ 48" OC SEE FOUNDATION PLANS FOR STEEL HANDRAIL PER SPECIFICATIONS, SURFACE MOUNTED TO STAIR TREAD PER MANUFACTURER RECOMMENDATIONS HEATED STAIR, SEE DETAIL HEATED WALK SIM 111/2" 11" 1/2"7"#5 BARS AT EACH RISER, TOP AND BOTTOM (3) #5 BARS CONTINUOUS 2" CLOSED CELL FOAM ICE MELT LOOP 4" GRAVEL BASE ANGULAR FILL 2" STONE TREAD STONE VENEER TO MATCH ELEVATIONS. INSTALLED PER MANUFACTURER RECOMMENDATIONS. HANDRAIL TOP MOUNTED TO STAIR TREAD PER MANUFACTURER RECOMMENDATIONS. STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. SCALE: 3/4" = 1'-0" 1 Entrance Stair Section A5.02 SCALE: 1 1/2"= 1'-0" 2 Deck Stair Tread Detail A5.02 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Entrance Stair Cross Section Drawing: Entrance Stair Cross Section Scale: 1/2" = 1'-0", 3/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/26/18 Date printed: STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. Varies2'-0"2'-0" 1'-4" 6'-21/4"8" 8" 8" RETAINING WALL, (1'-6" max- sim) SEE RETAINING WALL DETAILS 8" POURED CONCRETE WALL UNDISTURBED EARTH CONCRETE FOOTING: SEE FOOTING PLAN HANDRAIL, SEE SPECIFICATIONS. SURFACE MOUNT TO TOP OF WALL PER MANUFACTURER'S RECOMMENDATIONS. #5 @ 16" EW (3) #5 CONTINUOUS 4" PERFORATED FOOTING DRAIN, SEE CIVIL CONCRETE STAIR STRUCTURE, #5 @ 16" OC., EW. (HEATED) STONE TREAD AND RISER, SEE SPECIFICATIONS EARTH FILL PER GEOTECH REPORT 6" TOPSOIL BY OTHERS (NIC) MIRADRAIN 6000 DRAINAGE SYSTEM, OR EQUAL; INSTALL PER MANUF. SPECIFICATIONS. ANGULAR FILL GRAVEL FILL WITH NOON-WOVEN GEOTEXTILE FABRIC 2" CLOSED CELL INSULATION STONE CLADDING PER SPECIFICATIONS 4" CRUSHED STONE BASE SCALE: 3/4" = 1'-0" 2 ENTRANCE STAIR CROSS SECTION A5.03 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 02 Flat Ceilings 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1:2.39, 1" = 1'-0", 1 1/2"= 1'-0", 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. TITLE DRAWING NO. DRAWN BY XGard 2.0 NP019-A-0-A CCD DMMH 08/12/2013DATE MATERIAL: SUPPLIED HARDWARE: OTHER: 6005A T61 The Right Way! METAL ROOF INNOVATIONS, LTD. 8655 TABLE BUTTE RD COLORADO SPRINGS, CO 80908 719-495-0518 719-495-0045 (FAX) EST ASSEMBLY WEIGHT : SCALE: S-5!® PRODUCTS ARE PROTECTED BY MULTIPLE U.S. PATENTS INCLUDING 5,228,248, 5,983,588 AND6,164,033 (OTHERS ISSUED AND PENDING). EUROPEAN PATENTS ARE ALSO APPLIED FOR AND PENDINGUNDER THE PATENT COOPERATION TREATY WITH DIVISIONAL FILING RIGHTS RETAINED. METAL ROOFINNOVATIONS , LTD. (LICENSOR OF S-5!® TECHNOLOGY) AGGRESSIVELY PROSECUTES PATENT INFRINGEMENT. FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST INFORMATION AND CLAMP INSTALLATION INFORMATION PLEASE VISIT: WWW.S-5.COM 3.27" 5.28" 8.57" 1.50" 3.2" 6.4" PIPE STRAP M8 HEX FLANGE BOLT #8 TEK SCREW M8 HEX FLANGE BOLT S-5-CLAMP 2" (WALL: .075") NEX2PIPE #8 TEK SCREW S-5-CLAMP 2" (WALL: .075") NEX2 PIPE .200" 10.960" LOAD CALC FOR PIPE ONLY 3"3'-0" MAX OC. KUEKA STUDIOS, ITHICA STYLE; CABLE RAIL W/ HANDRAIL; SEE SPECIFICATIONS FOR COLOR AND HANDRAIL MATERIAL SURFACE MOUNT PER MANUFACTURER RECOMMENDATIONS 5/8" 111/4" 3"7 1/4" ROXUL INSULATION 3" CLOSED CELL INSULATION (R19.5) 16" LVL CEILING STRUCTURE PER MC SHOP DRAWINGS, SHAPED AS INDICATED COR-A-VENT S400 STRIP VENT IN EACH BAY. WRAP MEMBRANE ONTO SHEATHING, UNDER TRIM PIECE 1x WOOD TRIM BEAM, SEE MC SHOP DRAWINGS 5" MIN (R-25) RIGID INSULATION ON TOP OF SHEATHING, TAPERED PER ROOF PLAN. 1/2" PROTECTION BOARD EPDM ROOFING DOWN KNEE WALL, AND ONTO FLAT ROOF AREA. 14" LVL CEILING STRUCTURE PER MC SHOP DRAWINGS 2x6 FASCIA BOARD HIGH SIDE EAVE DETAIL PER ROOFING MANUFACTURER. LOW SLOPE STANDING SEAM METAL ROOFING PER SPECIFICATIONS ON GRACE ULTRA SELF ADHERED UNDERLAYMENT FOR HIGH TEMPERATURE APPLICATIONS. 3" CLOSED CELL INSULATION. (2) LAYERS 5.5" ROXUL INSULATION (R-46) 2X12 RIM JOIST 2X6 RIM JOIST 14" LVL RIM JOIST 5/8" GYP BD CEILING 1/2" OSB COMPRESSION STRIP 5/8" 61/8" 1/2" 33/8" 31/8" 1/4" 63/4" SEE CLADDING DETAILS33/4"1/4" 1"11/4"1/2" MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS INSTALLATION BRACKET SUPPLIED BY WINDOW MANUFACTURER: 6"-8" FROM CORNER AND 24" MAX IN FIELD. EXTERIOR CLADDING. SEE BUILDING ELEVATIONS AND CLADDING DETAILS UNILUX TURN-TILT WINDOW; INSTALLATION BY MC 25mm SILL EXTENSION SUPPLIED BY WINDOW MANUFACTURER; INSTALLED BY UNILUX EXTERIOR CLADDING. SEE ELEVATIONS, SPECIFICATIONS, AND DETAILS IN SECTION 35. FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS (1/2" SHIM SPACE ALL SIDES) 1 1/2" BLOCKING AT SILL. (LEAVE SPACES FOR CLIPS AS REQUIRED.) WD/ALUM. UNILUX UNIT; HOLD UNIT 1/4" BACK FROM SHEATHING (TYP.) MOUNTING BRACKET SUPPLIED BY UNILUX; INSTALLED BY MC RUBBER GASKET SNAP ON END CAP (2 PER WINDOW) ALUMINUM SILL (pre-cut to fit opening) 1/2" x 1 1/2" CONTINUOUS OSB BLOCKING, CENTERED ON SILL EXTENSION. WD/ALUM. UNILUX UNIT; HOLD UNIT 1/4" BACK FROM SHEATHING (TYP.)INTERIORINTERIOREXTERIORTYPICAL JAMB HEAD EXTERIOR SILL SHIP LOOSE ITEMS: 1. ALUMINUM SILL (custom lengths for each unit) w/ (2) END CAPS PER WINDOW. SEE CLADDING DETAILS FOR SILL DEPTH. 2. RUBBER GASKET FOR SILL INSTALLATION. 33/8" 31/8" 1/4" 6/4 INTERIOR WINDOW SILL ON 2x2 BLOCKING; SEE FINISH SCHEDULE FOR SELECTION EXTERIOR CLADDING BEYOND. SEE BUILDING ELEVATIONS AND CLADDING DETAILS CORNER BEAD WRAP SECOND LAYER OF ZIP TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS (1/2" SHIM SPACE ALL SIDES) TEAR AWAY BEAD AT FRAME 5/8" DRYWALL; SEE FINISH SCHEDULE FOR FINISH LEVEL WALL BY MC; SEE WALL SECTIONS MOUNTING BRACKETS SUPPLIED BY UNILUX; INSTALLED BY MC WRAP 6" ZIP TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. CUT AND FOLD OUTER LAYER OF ZIP TAPE AT BOTTOM CORNERS OF JAMB; BEYOND TRIM OFF EXCESS FOAM AT CORNERS AS REQUIRED AFTER DRYING. WRAP 6" ZIP TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. WRAP SECOND LAYER OF ZIP TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. WRAP 6" ZIP TAPE INTO R.O. PER MANUFACTURER RECOMMENDATIONS, ALL SIDES PRIOR TO INSTALLING WINDOWS. WRAP SECOND LAYER OF ZIP TAPE ONTO WINDOW FRAME +/- 1/2" PRIOR TO FOAM INSTALLATION, HEAD AND JAMBS. 63/4" 61/4"5"RIM JOIST ON 5/8" WOOD COMPRESSION STRIP EXTERIOR WALL CONSTRUCTION PER MC SHOP DRAWINGS. PAC-TITE GOLD COPING 4.5; INSTALL PER MANUFACTURER'S SPECIFICATIONS. 3" CLOSED CELL INSULATION (R-19.5) ROOF; 5/8" ZIP SHEATHING (EXT.), GLUED & NAILED, OVER 14" LVL's PER MC SHOP DRAWINGS. MEMBRANE ROOFING OVER 1/2" PROTECTION BOARD OVER 5" MINIMUM RIGID INSULATION; INSULATION TAPERED 1/4"/FT. FOR DRAINAGE. SEE SPECIFICATIONS FOR MEMBRANE SELECTION. CLADDING PER SPECIFICATIONS AND ELEVATIONS. 5-1/2", R-23 ROXUL INSULATION HELD IN PLACE WITH SIMPSON "IS" TYPE (OR EQUAL) INSULATION SUPPORTS SIZED PER JOIST SPACING PROVIDE DRYWALL FINISH LEVEL PER SPECIFICATIONS.MIN.CEILING: 5/8" DRYWALL PARAPET WALL; 2x4's @ 24" O.C. BETWEEN 5/8" ZIP SHEATHING (EACH SIDE) 2x PARAPET WALL CAP; FIELD INSTALL FOR COPING 5.02 SCALE: 1:2.39 1 Details: Snow Guard A5.04 SCALE: 1" = 1'-0" 2 Railing Detail A5.04 SCALE: 1 1/2"= 1'-0" 3 Monopitch Roof At Peak A5.04 SCALE: 3" = 1'-0" 4 Window HJS A5.04 SCALE: 1 1/2"= 1'-0" 5 Standard Parapet Wall A5.04 All roofing assemblies to meet Class A ratings 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.05 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. NOTE: FINISHED FLOORING SCOPE MAY VARY BY MODULE. REFER TO PLANS AND SPECIFICATIONS FOR CLARIFICATION. 101/4"5/8" 111/4" 3/4"1'-0"DBL. 2x10 PT SILL PLATE ON NEOPRENE SILL GASKET (BETWEEN ALL SILL PLATES); ATTACH WITH BOLTS AND WASHERS AS SUPPLIED BY SUPERIOR WALLS. MIN 2 BOLTS PER BOARD, MAX 4'-0" O.C. DOUBLE RIM JOIST PER MC SHOP DRAWINGS BASE; SEE FINISH SCHEDULE AND DETAIL FINISHED FLOOR OVER WARMBOARD, SEE FINISH SCHEDULE FLOOR STRUCTURE PER MC SHOP DRAWINGS; FILL CAVITIES WITH FIBERGLASS ACOUSTIC BATT INSULATION. VERIFY TERMITE SHIELD REQUIREMENTS W/ TABLE R301.2(6) IN THE IRC & WITH LOCAL JURISDICTION. IF REQUIRED, INSTALL CONTINUOUS METAL TERMITE SHIELD BETWEEN TWO LAYERS OF SILL SEALER. SHIELD SHALL EXTEND BEYOND INSULATION ON INTERIOR. SEE IRC SECTION R318 FOR MORE INFORMATION. 2x8 WALL PER MC SHOP DRAWINGS, FILLED WITH CLOSED CELL FOAM INSULATION (R 36). ALL SHEATHING SEAMS TAPED WITH ZIP TAPE. CLADDING, SEE SPECIFICATIONS FOR ATTACHMENT AND FINISH. FURRING TO ALIGN WITH WALL STUDS. PROVIDE INSECT PROTECTION IN SHIM SPACE AT BOTTOM AND TOP. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION 2x6 FRAMING @ 16" O.C. FILLED W/ CLOSED CELL FOAM INSULATION INSULATE JOIST SPACE WITH CLOSED CELL FOAM FROM RIM JOIST TO BLOCKING. FINISH SHEATHING AS REQUIRED, SEAL BOTTOM CORNER WITH ZIP TAPE. SIDING MATERIAL WRAPS FOR SOFFIT SWA FOUNDATION WALL; SEE SHOP DRAWINGS FOR ADDITIONAL INFORMATION. EXTERIOR CLADDING. SEE ELEVATIONS AND SPECIFICATIONS. FILL SHIM SPACE WITH MINIMAL EXPANDING FOAM RATED FOR USE AT WINDOWS (1/2" SHIM SPACE ALL SIDES) MOUNTING BRACKET SUPPLIED BY UNILUX; INSTALLED BY MC TEAR AWAY BEAD AGAINST WINDOW FRAME BASE BELOW INTERIOR EXTERIOR SHIM OUT WALL AS REQUIRED, MIN 1 1/2" 1 1/2" RIGID INSULATION 5/8" DRYWALL; FINISH PER SPECIFICATIONS STRUCTURE PER MC SHOP DRAWINGS SITE INSTALLED THRUST BEAM PER MC SHOP DRAWINGS 7/16" OSB FOR SHEAR PER MC SHOPS. INSTALLED AFTER THRUST BEAM CLEAR ANODIZED, EXTRUDED ALUMINUM (.050" NOMINAL WALL THICKNESS), CORNER MOLD W/ 3/4" FACE FLANGE WOOD SIDING. MITER CORNERS AT ALUMINUM TRIM PIECE. 1x4 PT FURRING 3/4" PT FURRING STRIP MIN 2 SUPPORTS FOR ALL BOARDS WOOD CLADDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. ZIP SHEATHING OVER MODULE FRAMING 1/2" MDF SHEATHING; PAINTED (5) WOOD VENEER PLYWOOD SHELVES (2) 2'-0" x 7'-0" SOLID WOOD DOORS; APPLY WOOD SIDING TO DOORS SO THEY APPEAR HIDDEN USE WOOD MATERIAL TO HIDE ALL EXPOSED ROUGH FRAMING MATERIAL OR I.L.O. FURRING WHEN NECESSARY 11/2" 5/8" 51/2" 5/8"81/4"67/8"67/8" 3/4"3/4"WALL; SEE MC SHOP DRAWINGS WOOD SIDING. MITER CORNERS AT ALUMINUM TRIM PIECE. CLEAR ANODIZED, EXTRUDED ALUMINUM (.050" NOMINAL WALL THICKNESS), CORNER MOLD W/ 3/4" FACE FLANGE WOOD SIDING. END MATCHED JEM™ JOINT DOES NOT NEED TO FALL ON SUPPORT; VERIFY MATERIAL AND WHERE JOINT NEEDS TO MEET MIN 2 SUPPORTS FOR ALL BOARDS WOOD SIDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. WOOD SIDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. 5/8" ZIP SHEATHING ALL SEAMS TAPED CLEAR ANODIZED, EXTRUDED ALUMINUM (.050" NOMINAL WALL THICKNESS), CORNER MOLD W/ 3/4" FACE FLANGE WOOD SIDING 1x4 PT FURRING 1x4 PT FURRING 1x4 PT FURRING 3/4" PT FURRING STRIP 5-1/2" CLOSED CELL FOAM INSULATION (R-36) 5-1/2" CLOSED CELL FOAM INSULATION (R-36) 5-1/2" CLOSED CELL FOAM INSULATION (R-36) 5-1/2" CLOSED CELL FOAM INSULATION (R-36) PT FURRING, ALIGN WITH STUDS 2x6 WALL BY MANUFACTURER 3/4" PT FURRING STRIP VERTICAL SECTION INSIDE CORNER OUTSIDE CORNER HORIZONTAL SECTION VERIFY WITH PROJECT DRAWINGS10 1/4"1'-03/4"4"STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. HOLD VENEER 4" MIN UP FROM GRADE SEE ELEVATIONS AND CLADDING DETAILS FOR CLADDING AT EXTERIOR WALLS. POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION INSECT PROTECTION AT BOTTOM OF FURRING 1/4" AIR GAP BETWEEN STONE AND SIDING BREAK METAL FLASHING, COLOR TO MATCH WINDOW SILLS PROVIDE AND INSTALL MOD STRAPS PER MC SHOP DRAWINGS. (LC PROVIDES AND ATTACHES TO SILL PLATE, SET CREW ATTACHES TO RIM JOIST) WRAP ZIP TAPE ONTO SUPERIOR WALL APPROX. FINISH GRADE WITH POSITIVE SLOPE (5%) AWAY FROM DWELLING (6" per 10' MIN.) INSECT PROTECTION AT BOTTOM OF FURRING BREAK METAL FLASHING, COLOR TO MATCH WINDOW SILLS 2x10 PT SILL PLATE ON NEOPRENE SILL GASKET; ATTACH TO STEEL AS REQ'D 5/8" DRYWALL WRAP ZIP TAPE TO COVER END OF SHEATHING; PROVIDE AND INSTALL STRIP OF 5/8" EXTERIOR PLYWOOD TO COVER SILL PLATE AND BLOCKING. BLOCKING AS REQ'D TO ATTACH PLYWOOD AND DRYWALL AT STEEL BEAM UNILUX WINDOW UNIT; SET BACK 21/8" FROM EDGE OF SUPERIOR WALL DRYWALL RETURNS TO UNILUX WINDOW; TEAR AWAY BEAD ALONG WINDOW W12x30 STEEL BEAM; SET BACK 21/8" FROM EDGE OF SUPERIOR WALL; INSULATE ON BOTH SIDES OF BEAM STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON 1/2" CEMENT BOARD ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. 2x FRAMING FOR WINDOW, DRYWALL, AND EXTERIOR TRIM ATTACHMENT; ATTACH TO STEEL AS REQ'D TOP OF SUPERIOR WALL BEYOND; STEEL BEAM TO BEAR ON SUPERIOR WALL SELF ADHESIVE EPDM FLASHING OVER METAL FLASHING; ALLOW AIR SPACE FOR DRAINAGE FROM PT FURRING TO WINDOW TRIM WALL; SEE BUILDING SECTIONS OR WALL SECTIONS FOR INFORMATION WOOD SIDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. WALL; SEE BUILDING SECTIONS OR WALL SECTIONS FOR INFORMATION WOOD SIDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) METAL FLASHING METAL FLASHING WOOD SIDING, FASTENED WITH SHIGA STAINLESS STEEL SCREWS INTO CORNER OF TONGUE ON 45° ANGLE TO PT FURRING. FURRING TO ALIGN WITH WALL STUDS. WALL; SEE BUILDING SECTIONS OR WALL SECTIONS FOR INFORMATION BACKER ROD AND SEALANT METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) VERTICAL - METAL/WOOD SECTION - TOP VERTICAL - METAL/WOOD SECTION - BOTTOM HORIZONTAL - METAL/WOOD SECTION STRUCTURAL NOTES:1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements anddetails of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. SCALE: 1 1/2"= 1'-0" 1 Floor Overhang A5.05 SCALE: 1 1/2"= 1'-0" 2 Living Room Post Detail A5.05 SCALE: 1 1/2"= 1'-0" 3 Balcony Storage Doors A5.05 SCALE: 1 1/2"= 1'-0" 4 Cladding Details - Wood A5.05 SCALE: 1 1/2"= 1'-0" 5 Cladding Transition: Wood to Stone A5.05 SCALE: 1 1/2"= 1'-0" 6 Steel beam over window in SWA A5.05 SCALE: 1 1/2"= 1'-0" 7 Cladding Details - Metal A5.05 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 03 04 HVAC Strategy Change Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.06 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.5"1'-3"101/2" 101/2" 1'-9"75/8" 75/8"1'-31/4"2" ±STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION UNILUX LIFT AND SLIDE DOOR SILL GRACE VAPROSHIELD FLASHING OR EQUAL CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK2x6 PT RIM JOIST FOR DECK FRAMING 2x6 PT DECK FRAMING @ 16" O.C. ON PEDESTALS (2) 2x6 PT RIM JOIST FOR RAILING SUPPORT 2x4 PT BLOCKING FOR ADDITIONAL RAILING SUPPORT; INSTALL IF NEEDED DECKING; SEE SCHEDULES FOR MATERIAL AND SIZE BACKER ROD AND SEALANT EWP FINISHED FLOORING ON WARMBOARD SHEATHING; SEE FINISH SCHEDULE FLOOR STRUCTURE; 3/4" PLYWOOD SUBFLOOR ON 2x12 JOIST @ 16" O.C. W/ SOLID BRIDGING AT CENTER OF SPAN. SITE BUILT, BENCH WITH STEPS; 2x4 FRAMING WRAPED IN 3/4"PLYWOOD; BENCH TO BE CLAD IN EWP FLOORING MATERIAL; RABBIT TREAD AND RISER, AND ROUND OVER THE EWP FLOORING EDGE 1/8" DURA SCUPPER DRAIN (CANTED) #SCP44C BY MARATHON ROOFING PRODUCTS INSTALLED WITH ROOFING. CUT DURA SCUPPER DRAIN BACK AFTER FINISH CLADDING APPLIED; ENOUGH FOR WATER TO RUN OUT SCUPPER, BUT NOT TO RUN ONTO WALL. AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING SYSTEM OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 51/2" 33/4" 91/4" 15/8"BOTTOM OF METAL TO ALIGN WITH BOTTOM OF METAL @ FRONT ENTRY WRAP WOOD SIDING AROUND INTERIOR PERIMETER OF BALCONY TO UNDERSIDE OF DECK JOISTS 2x10 PT DECK JOISTS @ 16" O.C.; CANTILEVERED INTO MODULE; SEE FRAMING PLANS BACKER ROD AND SEALANT DECKING; SEE SCHEDULES 2x4 PT FRAMING Simpson Strong-Tie® HU210, INVERTED; TYP. OF CANT. BALCONY DECK JOISTS (2) 2x10's AT DECK PERIMETER METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) WOOD BLOCKING FOR RAILING MOUNTING; COORDINATE INSTALL WITH METAL CLADDING INSTALLERS; SOLID WOOD BLOCKING FROM INSIDE OF METAL CLADDING TO DECK FRAMING CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK; SIDE MOUNTED POST ON BALCONY .040 ALUMINUM, CUSTOM MADE FLASHING OVER FRAMING AND METAL CLADDING BLOCKING BETWEEN DECK JOISTS FLASHING AS REQ'D CONTINUE INSULATION UNDER WARMBOARD 11/4" 3" 6" 6" DECKING; SEE SCHEDULES 3-3/4" SDS SCREWS; ATTACH AS DIMENSIONED (TYP. OF 4) 5-3/4" SDS SCREWS THRU SHEATHING TO WALL; ATTACH AS DIMENSIONED (TYP. OF 4)11/2" 61/4" 11/2"BOTTOM OF METAL TO ALIGN WITH BOTTOM OF METAL @ FRONT ENTRY WRAP WOOD SIDING AROUND INTERIOR PERIMETER OF BALCONY TO UNDERSIDE OF DECK JOISTS (2) 2x10's AT DECK PERIMETER METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) WOOD BLOCKING FOR RAILING MOUNTING; COORDINATE INSTALL WITH METAL CLADDING INSTALLERS; SOLID WOOD BLOCKING FROM INSIDE OF METAL CLADDING TO DECK FRAMING CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK; SIDE MOUNTED POST ON BALCONY .040 ALUMINUM, CUSTOM MADE FLASHING OVER FRAMING AND METAL CLADDING (2) 2x10 PT FRAMING ATTACHED TO HOUSE WITH SDS SCREWS AS INDICATED; TYP. OF 2 LOCATIONS; SEE FRAMING PLANS BACKER ROD AND SEALANT 2x10 RIM JOIST OF MODULE 2x4 PT FRAMING FLASHING AS REQ'D Simpson Strong-Tie® HUC210 STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 5.03 5.03 5.03 5.04 5.04 SCALE: 1 1/2"= 1'-0" 1 Deck at Dining Room A5.06 SCALE: 1 1/2"= 1'-0" 2 Balcony Detail A5.06 SCALE: 1 1/2"= 1'-0" 3 Balcony Detail A5.06 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.07 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.103/8"2x4 PT SILL PLATES ON NEOPRENE SILL GASKET; ATTACH WITH BOLTS AND WASHERS AS SUPPLIED BY SUPERIOR WALLS. MIN 2 BOLTS PER BOARD, MAX 4'-0" O.C. DOUBLE 2x12 RIM JOIST CLOSED CELL FOAM INSULATION AT RIM JOIST (R-30 MIN) 5/8" DRYWALL MAY OCCUR, SEE FINISH SCHEDULE STONE VENEER ON MVIS VENEER MORTAR BY LATICRETE. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. 2x6 JOISTS @ 12" O.C.; HUNG FROM MODULE STRUCTURE; JOIST SPACES FILLED W/ CLOSED CELL FOAM (2) 2x4 BLOCKING FOR FRAMING SUPPORT; GLUE AND NAIL TO FRAMING HEATED DOWNSPOUT FOR DRAINAGE OF TERRACE FLOOR; SEE FLOOR PLANS FOR DOWNSPOUT LOCATION (2) 2x4's AND ADDT'L BLOCKING; SUPPORT FOR ROOF FRAMING METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) JOIST HANGER 2-1/4" SDS SCREWS @ 16" O.C. 342 RECTANGULAR PLASTICE WEEP HOLE BY HOHMANN & BARNARD OR EQUAL @ 24" O.C.5" 2"AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING SYSTEM OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS LIGHTWEIGHT CONCRETE W/ 6x6 W2.9 x 2.9 W.W.F. REINFORCING, SLOPED TO DRAIN; TAPERED 1/4"/FT.5/8" ZIP SHEATHING; GLUED AND NAILED TO FRAMING WRAP ROOF MEMBRANE OVER SUPERIOR WALL MORTAR BED; VERIFY DEPTH OF BED FOR STONE THICKNESS 2" THICK STONE PAVERS W/ NON-SLIP SURFACE AND SNOWMELT SYSTEM; COLOR TO BE DETERMINED BACKER ROD AND SEALANT METAL FLASHING W/ DRIP EDGE; ATTACH TO VENEER AS REQ'D STEEL CABLE RAILING PER SPECIFICATIONS. TOP MOUNTED PER MANUFACTURER SPECIFICATIONS.3/4"91/4"5/8"63/8"5/8"5'-31/8" 1" 1"1"BOTTOM OF METAL CLADDING TO ALIGN WITH BOTTOM OF ALPOLIC METAL @ BALCONIES WOOD CLADDING; SEE SCHEDULES FOR MATERIAL AND SIZE METAL CLADDING W/ INTEGRAL COPING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) (2) 11/2"x 91/4" LVL's @ 8" O.C.; SEE FACTORY FRAMING PLANS 3/4" STRAPPING ATTACHED TO LVL'S FOR FINISH SOFFIT MATERIAL ATTACHMENT 5/8" ZIP SHEATHING; GLUED AND NAILED TO FRAMING 2x10 NAILER FOR SHEATHING AND STRAPPING 3/4" RIP OF PLYWOOD TO RUN CONTINUOUS ALONG LVL WRAP ROOF MEMBRANE OVER PARAPET 5/8" ZIP SHEATHING AROUND PARAPET AND FACE OF ENTRY ROOF; USE ZIP TAPE AT ALL JOINTS PER MANUFACTURER'S RECOMMENDATIONS COR-A-VENT™ PS-400 STRIP VENT; INSTALL STRIP VENT AT FRONT AND BACK OF ROOF STRUCTURE PER MANUFACTURERS RECOMMENDATIONS SITE BUILT PARAPET; 2x4's @ 24" O.C.105/8" 7"AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS SCALE: 1 1/2"= 1'-0" 1 Entry Terrace A5.07 SCALE: 1 1/2"= 1'-0" 2 Entry Roof A5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.08 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.2"±PEDESTALS; PEDESTAL NEEDS TO BE TALL ENOUGH TO ALLOW WATER TO FLOW UNDERNEATH DECK STRUCTURE; DIFF. TYPES MAY BE REQUIRED TO ACCOMMODATE ROOF PITCH STEEL BEAM; SEE STRUCTURAL PLANS FOR SIZE 2x NAILING PLATE; SCREWED OR BOLTED TO STEEL BEAM FLANGE 2x10's @ 12" O.C. JOIST CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION TAPERED INSULATION; PART OF MEMBRANE ROOF SYSTEM (3) 2x10's; BLOCKING FOR MODULE BEARING 2x4 NAILER FOR DRYWALL MODULE SECTION BEING SET ON GARAGE ROOF FRAMING AND STEEL BEAM WOOD SIDING, SEE EXTERIOR FINISH SCHEDULES FOR ATTACHMENT AND FINISH. FURRING TO ALIGN WITH WALL STUDS. PAIR OF L 3-1/2"x3-1/2"x1/4 W/ 2 ROWS OF 3/4" A325N BOLTS DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS MODULE MAY REQUIRE SHIMMING; VERIFY AFTER GARAGE ROOF FRAMING COMPLETE 1'-11/8"2" PAC-TITE GOLD COPING SYSTEM BY PAC- CLAD 2x PARAPET CAP NAILER; RIP TO SIZE CONDUCTOR HEAD AND DOWNSPOUT; SEE SCHEDULES FOR COLOR AND SIZE PART OFWALLFRAMINGPART OFTERRACEWALLFRAMINGLINE OF ROOF SLOPE PEAK IN OTHER DIRECTION BACKER ROD AND SEALANT LINE OF 2x4 FRAMED WALL BEYOND ALUMINUM DRIP CAP, BENT ON SITE; TAPE OVER EDGE AND INSTALL PRIOR TO FURRING STRIPS 73/4" VIF METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING SYSTEM OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" THICK STONE CAP, 12" WIDE; SEE SCHEDULE FOR SELECTION; SLOPE AS REQ'D PARAPET WALL: 2x4@ 24" O.C. BETWEEN 5/8 ZIP SHEATHING, ALL SEAMS TAPED. WRAP MEMBRANE TO FRONT OF WALL. PROVIDE .10 X 1" ALUMINUM TERM BAR BY BEST MATERIALS OR EQUAL. STEEL BEAM; SEE STRUCTURAL PLANS FOR SIZE STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON GALVANIZED METAL LATH WITH MVIS SCRATCH COAT ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. 1x WOOD TRIM TO MATCH SIDING; EDGE OF TRIM TO EXTEND 1/4" BEYOND STONE VENEER FURTHEST PROJECTION GARAGE DOOR WEATHER STRIP; PACK OUT ON SIDES AS REQ'D FOR STONE VENEER BUILD UP STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON GALVANIZED METAL LATH WITH MVIS SCRATCH COAT ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. TO ALIGN CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK 36" HIGH RAILING 97/8" 3'-101/2" 2" LINE OF ROOF SLOPE PEAK IN OTHER DIRECTION BACKER ROD AND SEALANT METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE STEEL BEAM; SEE STRUCTURAL PLANS FOR SIZE CONDUCTOR HEAD AND DOWNSPOUT; SEE SCHEDULES FOR COLOR AND SIZE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING SYSTEM OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" STONE CAP, 12" WIDE; SEE SCHEDULE FOR SELECTION; SLOPE AS REQ'D. WATER RESISTANT BARRIER - 2 LAYERS STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON GALVANIZED METAL LATH WITH MVIS SCRATCH COAT ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR (BY LATICRETE) ON GALVANIZED METAL LATH WITH MVIS SCRATCH COAT ON 1x PT FURRING. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. PEDESTALS NEEDS TO BE TALL ENOUGH TO ALLOW WATER TO FLOW UNDERNEATH DECK STRUCTURE GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION 2x NAILING PLATE; SCREWED OR BOLTED TO STEEL BEAM FLANGE CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK 36" HIGH RAILING 101/4" 71/4" 51/2" 2" STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. PAC-TITE GOLD COPING SYSTEM BY PAC- CLAD 2x PARAPET CAP NAILER; RIP TO SIZE STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. VIF BACKER ROD AND SEALANT POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" STONE CAP; SEE SCHEDULE FOR SELECTION CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK WRAP MEMBRANE TO FRONT OF WALL. PROVIDE .10 X 1" ALUMINUM TERM BAR BY BEST MATERIALS OR EQUAL. GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION TO ALIGN 36" HIGH RAILING 101/4"2'-2" 2'-93/8"2" 51/2" STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. BACKER ROD AND SEALANT POWER WASH SUPERIOR WALL PRIOR TO STONE APPLICATION METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING SYSTEM OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" THICK STONE CAP, 12" WIDE; SEE SCHEDULE FOR SELECTION; SLOPE AS REQ'D CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION CONNECTION ON SITE BY SUPERIOR WALLS 36" HIGH RAILING SCALE: 1 1/2"= 1'-0" 1 Terrace Detail A5.08 SCALE: 1 1/2"= 1'-0" 2 Terrace End Detail A5.08 SCALE: 1 1/2"= 1'-0" 3 Terrace End Detail A5.08 SCALE: 1 1/2"= 1'-0" 4 Terrace End Detail A5.08 SCALE: 1 1/2"= 1'-0" 5 Terrace End Detail A5.08 @ Garage thru Module and Garage Roof @ Garage thru Wood Framed Parapet @ Garage thru Wood Stone Clad Wall @ Garage thru SWA Parapet @ Garage thru SWA Stone Clad Wall 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.09 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. 101/4"75/8" 75/8"101/2" 10 1/2"1'-31/4"1'-9" 51/2"5" 2" ±3'-1" ± EWP FINISHED FLOORING ON WARMBOARD SHEATHING; SEE FINISH SCHEDULE FLOOR STRUCTURE; 3/4" PLYWOOD SUBFLOOR ON 2x12 JOIST @ 16" O.C. W/ SOLID BRIDGING AT CENTER OF SPAN. 5/8" DRYWALL APPLIED TO WALLS AND CEILING; CEILING DRYWALL TO BE SUPPORTED BY USG SUSPENSION GRID SYSTEM OR APPROVED EQUAL STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. PAC-TITE GOLD COPING SYSTEM BY PAC- CLAD 2x10 PARAPET CAP NAILER; RIP TO SIZE SITE BUILT, BENCH WITH STEPS; 2x4 FRAMING WRAPED IN 3/4"PLYWOOD; BENCH TO BE CLAD IN EWP FLOORING MATERIAL; RABBIT TREAD AND RISER, AND ROUND OVER THE EWP FLOORING EDGE 1/8" LIFT/SLIDE UNIT STEEL BEAM; SEE STRUCTURAL PLANS FOR SIZE JOIST CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION 5/8" DRYWALL APPLIED TO WALLS AND CEILING; CEILING DRYWALL TO BE SUPPORTED BY USG SUSPENSION GRID SYSTEM OR APPROVED EQUAL 2x12 RIM JOIST; PART OF MODULE 2X8 BLOCKING, EVERY OTHER JOIST SPACE. THROUGH BOLT TO BEAM AND NAIL TO RIM AND FLOOR JOISTS. SEE MC SHOPS FOR JOIST LAYOUT. POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION BACKER ROD AND SEALANT METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 PT DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" REALSTONE CAP; SEE SCHEDULE FOR SELECTION GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ 3" CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION; SUPPORT ROXUL W/ INSULATION SUPPORTS WRAP MEMBRANE TO FRONT OF WALL. PROVIDE .10 X 1" ALUMINUM TERM BAR BY BEST MATERIALS OR EQUAL. CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK EDGE OF RAILING AND EDGE OF STONE CAP TO ALIGN 10 1/4"2'-6" 2'-111/2"51/2"5"STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. POWER WASH SUPERIOR WALL PRIOR TO STONE APPLICATION BACKER ROD AND SEALANT METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE TO ROOFING MEMBRANE DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" STONE CAP; SEE SCHEDULE FOR SELECTION GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION CONNECTION ON SITE BY SUPERIOR WALLS SCALE: 1 1/2"= 1'-0" 1 Terrace End Detail A5.09 SCALE: 1 1/2"= 1'-0" 2 Terrace End Detail A5.09 @ Apartment thru SWA Parapet, Deck, and Site Built Bench w/ Steps @ Apartment thru SWA Stone Clad Wall 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 04 Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.10 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1" = 1'-0", 1 1/2"= 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.5" 4" 67/8"VARIESSEE BLDG. SECT.VARIES W/ EXT. FINISH 2" MEMBRANE AND PATCHES EXTEND OVER FLANGE CUSTOM RECTANGULAR CONDUCTOR HEAD WITH OPEN TOP. ALLOW MIN 2" CLEARANCE TO END OF SCUPPER. PROVIDE U SHAPED FACE AT CLADDING TO FIT UNDER SCUPPER. CUSTOM DOWNSPOUT. SEE BUILDING ELEVATIONS ANCHOR STRAPS TO MATCH DOWNSPOUT CLADDING TIGHT (+/-1/4" MAX GAP) TO SCUPPER ON ALL FOUR SIDES. ZIP TAPE ALL SIDES AT SHEATHING. DURA SCUPPER DRAIN (CANTED) #SCP44C BY MARATHON ROOFING PRODUCTS INSTALLED WITH ROOFING.6" 63/4" VARIESVARIESSEE BLDG. SECT.VARIESW/ EXT.FINISH COVER EDGE OF CANT WITH ROOF MEMBRANE PIECES. ADHERE PER MANUFACURER'S RECOMMENDATIONS PROVIDE RIGID INSULATION SUCH THAT BOTTOM OF OVERFLOW DRAIN IS 1" MIN ABOVE BOTTOM OF DRAIN TO CONDUCTOR HEAD DURA SCUPPER DRAIN (CANTED) #SCP44C BY MARATHON ROOFING PRODUCTS INSTALLED WITH ROOFING. CUT OFF END FLUSH WITH CLADDING AND PROVIDE TRIM TO MATCH CONDUCTOR HEAD ONCE CLADDING IS INSTALLED. PROVIDE ZIP TAPE ON ALL FOUR SIDES OF SCUPPER TUBE. INSTALL BLOCKING AT TOP AND BOTTOM OF SCUPPER TUBE ONCE TAPERED INSULATION IS IN PLACE. 10" VARIES; SEE PLANS/ELEV.1'-0"1"1" METAL TRIM TO MATCH CONDUCTOR HEADS. ATTACH WITH FLANGES AND SCREWS INSIDE SCUPPER TUBE ON TOP AND SIDES. TOP OF MEMBRANE CUSTOM CONDUCTOR HEAD AND DOWNSPOUT. CLADDING, SEE ELEVATIONS COPING, SEE SECTION 10 AND SPECIFICATIONS. REAR FACE OF CONDUCTOR HEAD IS U SHAPED TO FIT AROUND SCUPPER TUBE. TOP OF CONDUCTOR HEAD AND TOP OF OVERFLOW TRIM TO ALIGN.51/2" 33/4" 91/4" 15/8" 53/8"C 6x8.2 (GALVANIZED) C CHANNEL, SEE FRAMING PLAN 2x4 PT FRAMING; THICKNESS OF FRAMING TBD WHERE CLADDING TERMINATES STEEL TUBE POST, SEE FRAMING PLAN (2) 2x12's AT DECK PERIMETER; PRESSURE TREATED METAL CLADDING; INSTALL PER MANUFACTURERS SPECS.; CUSTOM COLOR: RAL8022 (TO MATCH EXTERIOR WINDOW FRAMES) ATTACH (2) 2x8's TO STEEL WITH SIMPSON HGA 10 STAINLESS STEEL ANGLES, WITH (4) 1/4" SS SCREWS INTO WOOD AND (4) 1/4" TEK SS SCREWS INTO C CHANNEL. USE Sikaflex CONSTRUCTION SEALANT FOR TEK SS SCREWS INTO C CHANNEL. PT WOOD BLOCKING FOR RAILING MOUNTING; COORDINATE INSTALL WITH METAL CLADDING INSTALLERS; SOLID WOOD BLOCKING FROM INSIDE OF METAL CLADDING TO DECK FRAMING CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK; SIDE MOUNTED POST ON BALCONY .040 ALUMINUM, CUSTOM MADE FLASHING OVER FRAMING AND METAL CLADDING 2x6 PT DECK JOISTS @ 16" O.C. WOOD SIDING, SEE EXTERIOR FINISH SCHEDULES FOR ATTACHMENT AND FINISH. FURRING TO ALIGN WITH WALL STUDS. WRAP WOOD SIDING AROUND INTERIOR PERIMETER OF BALCONY; LC TO DETERMINE WHERE CLADDING TERMINATES BACKER ROD AND SEALANT DECKING; SEE SCHEDULES FINISHED FLOOR; SEE SCHEDULES 1/2" THRU BOLT Simpson Strong-Tie® HUC28-2 HANGER; EACH SIDE STEEL POST STACKING LINE L 3x3x5/16; EACH SIDE; SHOP WELDED TO STEEL TUBE POST AND 1/2" THRU BOLTED TO WALL PLATE AND BLOCKING BELOW STEEL TUBE POST, SEE FRAMING PLAN 1/2" THRU BOLT Simpson Strong-Tie® HUC28-2 HANGER; EACH SIDE FLASHING AS REQ'D 1/2" x 4" x 1'-6" GALV. METAL PLATE; WELDED TO C CHANNEL; BOLT TO STEEL POST W/ 3/4" A325 BOLTS 2x6 PT LEDGER BOARD; ATTACH W/ 2-1/4" SDS SCREWS @ EA. WALL STUD CUT RIM JOIST AND SHEATHING TO ALLOW METAL PLATE CONNECTION TO STEEL POST INSTALL ZIP SHEATHING AND TAPE AFTER METAL PLATE GETS BOLTED; INSULATE IF POSSIBLE (2) 2x8's; BLOCKING MODULE WALL & FLR. FRAMING; SPACING FROM METAL POST MAY VARY; INSTALL BLOCKING AS REQ'D TO SECURE METAL POST TO FRAMING (2) 2x8's; BLOCKING ARMATHERM FRR THERMAL BREAK PLATE BETWEEN PLATE AND POST L 3x3x1/4; EACH SIDE; SHOP WELDED TO STEEL TUBE POST AND 1/2" THRU BOLTED TO WALL PLATE AND BLOCKING BELOW STEEL TUBE POST, SEE FRAMING PLAN WOOD CLADDING, SEE EXTERIOR FINISH SCHEDULES FOR ATTACHMENT AND FINISH. FURRING TO ALIGN WITH WALL STUDS. L 3x3x5/16; EACH SIDE; SHOP WELDED TO STEEL TUBE POST AND 1/2" THRU BOLTED TO THRU SHEATHING AND BLOCKING BELOW STEEL TUBE POST, SEE FRAMING PLAN 1/2" THRU BOLT ELEVATION OF STEEL POST BASE - BOTTOM 1/2" THRU BOLT Simpson Strong-Tie® HUC28-2 HANGER; EACH SIDE Simpson Strong-Tie® HUC28-2 HANGER; EACH SIDE 16d NAILS MODULE WALL & FLR. FRAMING; SPACING FROM METAL POST MAY VARY; INSTALL BLOCKING AS REQ'D TO SECURE METAL POST TO FRAMING BOTTOM WALL PLATE (2) 2x8's BLOCKING SILL PLATES POST; CONNECT FRAMING DIRECTLY TO STEEL POST WITH TEK SS SCREWS BOTTOM WALL PLATE; CLIP PLATE FOR POST AND ANGLE ATTACHMENT (2) 2x8 BLOCKING (2) 2x10's; FITTED UNDER POST LOAD (2) 2x10's; FITTED UNDER POST LOAD 4"1'-6"11/2"3"11/2"6"11/2"3"11/2"31/2"PLAN @ TOP OF POST CL L 3x3x5/16; EACH SIDE; SHOP WELDED TO STEEL TUBE POST AND 1/2" THRU BOLTED TO THRU SHEATHING AND BLOCKING BELOW Simpson Strong-Tie® HUC28-2 HANGER; EACH SIDE HSS STEEL TUBE; SEE FRAMING PLAN FOR SIZE BAR 4x3/4x20 EACH SIDE W/ 6 - 3/4" A325 BOLTS 1/2" x 4" x 1'-6" GALV. METAL PLATE; WELDED TO C CHANNEL; BOLT TO STEEL POST W/ 3/4" A325 BOLTS W/ SPACING INDICATED; ARMATHERM FRR THERMAL BREAK PLATE BETWEEN PLATE AND POST RIM JOIST CUT RIM JOIST AND SHEATHING TO ALLOW METAL PLATE CONNECTION TO STEEL POST FLOOR JOIST (2) 2x8's; BLOCKING 1/2" x 4" x 1'-6" GALV. METAL PLATE; WELDED TO C CHANNEL; BOLT TO STEEL POST W/ 3/4" A325 BOLTS W/ SPACING INDICATED; ARMATHERM FRR THERMAL BREAK PLATE BETWEEN PLATE AND POST 11/2"3" 3" 3" 2" 3" 3"11/2"1'-8"4"11/2" 3" 9" 3"11/2"1'-6"STEEL POST STACKING LINE CL HSS STEEL TUBE; SEE FRAMING PLAN FOR SIZE BAR 4x3/4x20 EACH SIDE W/ 6 - 3/4" A325 BOLTS ELEVATION OF METAL BAR @ POST STACKING 1/2" x 4" x 1'-6" GALV. METAL PLATE; WELDED TO C CHANNEL; BOLT TO STEEL POST W/ 3/4" A325 BOLTS W/ SPACING INDICATED; ARMATHERM FRR THERMAL BREAK PLATE BETWEEN PLATE AND POST STRUCTURAL NOTES:1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements anddetails of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design.5.04 SCALE: 1" = 1'-0" 1 Scupper at Downspouts A5.10 SCALE: 1" = 1'-0" 2 Scupper at Overflow A5.10 SCALE: 1" = 1'-0" 3 Scupper and Overflow Elevation A5.10 SCALE: 1 1/2"= 1'-0" 4 Balcony Detail @ Gallery thru Steel Post - Top A5.10 SCALE: 1 1/2"= 1'-0" 5 Steel Post Base Detail for Gallery Balcony - Bottom A5.10 SCALE: 1 1/2"= 1'-0" 6 Plan and Elevation C Channel and Metal Plate Connection A5.10 SCALE: 1 1/2"= 1'-0" 7 Elevation of Metal Connections for Gallery Balcony A5.10 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.11 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Exterior Details Scale: 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. 101/4" 2" 51/2" 2" 2"1'-1" 2"1'-3"1'-0" 3'-03/4" 1'-0"1'-1" 2"1'-3"STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. STONE VENEER ON MVIS VENEER MORTAR. APPLY VENEER MORTAR DIRECTLY TO POWER WASHED SUPERIOR WALLS SURFACE. SEE ELEVATIONS AND SPECS FOR STONE SELECTION. BACKER ROD AND SEALANT 1'-0" 91/8" 63/4" POWER WASH SUPERIOR WALL PRIOR TO REALSTONE APPLICATION METAL FLASHING W/ DRIP EDGE; SEAL/ ADHERE/ATTACH AS REQ'D DECKING ON 2x6 DECK JOISTS @ 16" O.C. ON PEDESTALS; SEE SCHEDULES FOR SELECTION; TAPER WHEN NECESSARY AMERICAN HYDROTECH 6125 MONOLITHIC MEMBRANE ROOFING OVER 5/8" ZIP SHEATHING; INSTALL PER MANUFACTURER'S RECOMMENDATIONS 2" STONE CAP; SEE SCHEDULE FOR SELECTION CABLE RAILING WITH POWDER COATED ALUMINUM POSTS AND ALUMINUM TOP RAIL, COLOR - RAVEN BLACK GARAGE ROOF FRAMING, 5/8" ZIP SHEATHING ON 2x10 RAFTERS @ 12" O.C.; CAVITY FILLED W/ CLOSED CELL SPRAY FOAM AND 2x6 ROXUL INSULATION CONNECTION ON SITE BY SUPERIOR WALLS PT BLOCKING BETWEEN DECK FRAMING FOR FIREPLACE FRAMING SUPPORT 2" STONE CAP; ADHERE TO METAL FRAMING AS REQ'D; SEE SCHEDULE FOR SELECTION METAL STUD FRAMING FOR FIREPLACE AND STONE SUPPORT REGENCY PLATEAU PTO30 OUTDOOR DECORATIVE GAS APPLIANCE; INSTALL PER OWNERS AND INSTALLATION MANUAL NOTES: THE PTO30 STATES THAT (2) VENTILATION GRILLS ARE REQUIRED FOR ALL ENCLOSURES TO ALLEVIATE MOISTURE AND ALLOW FOR AIR TO CIRCULATE. THE MIN. VENT SIZE RECOMMENDED IS 20" SQ EACH. HOWEVER, LEAVING THE BOTTOM OPEN TO THE RAISED DECK FRAMING AND PEDESTALS; THIS MAY VENTILATE ADEQUATELY ENOUGH; VERIFY W/ MANUFACTURER. OPTIONAL HARD WIRE KIT IS AVAILABLE; VERIFY W/ OWNER PRIOR TO INSTALLATION GAS LINE WILL BE RUN TO UNIT FOR FUEL SUPPLY STONE VENEER ON MVIS VENEER MORTAR ON CEMENT BOARD SECURED TO METAL FRAMING FLASHING AS REQ'D 36" HIGH RAILING 36" HIGH RAILING VERIFY UNIT OPENING W/ INSTALLATION MANUAL VERIFY UNIT OPENING W/ INSTALLATION MANUAL SCALE: 1 1/2"= 1'-0" 1 Terrace End Detail A5.11 @ Garage thru Outdoor Decorative Gas Appliance 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.50 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Interior Details Scale: 3/4" = 1'-0", 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.1'-33/4"2'-10"1'-33/4"CONCEALED TOILET CARRIER AND TANK. SEE SPECIFICATIONS. VERIFY DIMENSIONS PRIOR TO FRAMING. LEAVE SPACE OR CUT OUT SILL PLATE FOR WASTE PIPE. ACTIVATOR PLATE. SEE SPECIFICATIONS FOR SELECTION. SEE INTERIOR DRAWINGS FOR PLACEMENT OF ACCESSORIES. 2x6 MIN WALL AT WALL HUNG CARRIER. 1x6 FINISH GRADE WOOD EDGE. WOOD EDGE TO BE FLUSH W/ REVEAL EDGE; STAIN TO MATCH FLOOR FINISHED FLOORING OVER WARMBOARD, SEE FINISH SCHEDULE 5/8" DRYWALL 3/4" PLYWOOD SUBFLOOR WOOD BEAM MAY OCCUR; VERIFY WITH MC SHOP DRAWINGS DOUBLE 2x12 RIM JOIST CEILING STRUCTURE, SEE MC SHOP DRAWINGS. FLOOR STRUCTURE, SEE MC SHOP DRAWINGS 5/8" DRYWALL CEILING LC SCOPEMC SCOPE FRY REGLET "F" REVEAL; PART NUMBER DRMF-625-50 RAILING SYSTEM; SEE SCHEDULES; ATTACH TO STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS; SEE FLOOR PLAN FOR LAYOUT CAP, SEE SPECS FOR SELECTION. CEILING OF FIRST FLOOR BOX AND FLOOR OF SECOND FLOOR BOX MAY BE MISALIGNED; SHIM AS REQ'D TO ENSURE DRYWALL IS INSTALLED PLUMB SEE MC SHOP DRAWINGS FOR CONNECTION OF MODULES TO STEEL BEAM MODULES LALLY COLUMN. SEE BUILDING PLANS FOR SIZE AND SPACING 1/2" ISOLATION JOINT AT ALL COLUMNS. RADIANT FLOORING IN BASEMENT SLAB PER MECHANICAL PLANS. FINISHED FLOORING, SEE SPECIFICATIONS AND FLOOR PLANS. STEEL BEAM. SEE BUILDING PLANS FOR SIZE. PROVIDE BOLTED OR WELDED CONNECTION TO BEAM. UNDER SLAB INSULATION; SEE SPECIFICATIONS POURED IN PLACE CONCRETE PADS; SEE SHT. S.01 FOOTING PLAN FOR PAD DIMENSIONS, DEPTH, AND STEEL REINFORCING 2'-21/4" 113/4" 5/8"71/4"EQ(OTHER ENDOF COOLER)101/2"71/4" SINGLE GLAZED WALL SYSTEM: SOLARE BY AVANTI OR EQUAL SELF CLOSING HINGE BY GLASS WALL SYSTEM MANUFACTURER BOTTOM RAIL SURFACE MOUNTED TO FINISHED FLOOR SEE MC SHOP DRAWINGS FOR STRUCTURE AND MEP SYSTEMS IN WALL. WINE RACK SYSTEM: TWO SIDE THREE BOTTLE DEEP FTC FRAME KIT BY WINE RACKS AMERICA OR EQUAL. SCALE: 3/4" = 1'-0" 1 Wall Hung Toilet in 2x6 Wall A5.50 SCALE: 3/4" = 1'-0" 2 GALLERY RAILING A5.50 SCALE: 3/4" = 1'-0" 3 Lally Column Detail A5.50 SCALE: 1 1/2"= 1'-0" 4 WINE COOLER A5.50 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.51 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Stair Plans and Sections Scale: 1/2" = 1'-0", 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES.8'-33/8"5'-21/4"8'-47/8"4'-11/2" 1'-21/8"2'-10"2'-10"2'-10"2'-10"3/4" 1/2" 91/4" 31/8"31/4"21/2"3'-61/4"31/4"2"31/4"3'-61/4"21/2"10'-27/8"8'-2"PACK OUT WALL AS REQ'D AND ALIGN WITH WALL ABOVESUBFLOOR TO SUBFLOORROUGH OPENING FLOOR PLAN - OPEN TREAD STAIR (VIEWED FROM SECOND FLOOR) FRAMING TO FRAMING DRYWALL TO STUD; LC TO ALIGNMODULE WALL , PACK OUT AS REQ'D,THEN DRYWALL1 A5.52 2 A5.52 11'-21/2" STAIR TREAD - 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION; WRAPPED IN EWP STAIR STRINGER - 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE PERIMETER OF LANDING TO BE SAME THICKNESS AND MATERIAL AS STRINGER; PAINTED WHITE SITE BUILT LANDING; SEE ENLARGED DETAIL FOR ADDITIONAL INFO. RECESSED FIXTURE; SEE ELECTRICAL PLANS AND SCHEDULES FOR ADDITIONAL INFO STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO. TILE ON DITRA XL OVER WARMBOARD ON MODULE SUBFLOOR AND FRAMING STAIR TREAD - 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION; WRAPPED IN EWP STAIR STRINGER - 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO.; TYP. OF 6 ENGINEERED WOOD FLOORING ON WARMBOARD ON MODULE SUBFLOOR STAIR TREAD - 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION; WRAPPED IN EWP STAIR STRINGER - 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE PERIMETER OF LANDING TO BE SAME THICKNESS AND MATERIAL AS STRINGER; PAINTED WHITE SITE BUILT LANDING; SEE ENLARGED DETAIL FOR ADDITIONAL INFO. RECESSED FIXTURE; SEE ELECTRICAL PLANS AND SCHEDULES FOR ADDITIONAL INFO STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO. CABLE RAILING; SEE SCHEDULES FOR SELECTION WRAP RAILING AND CONNECT TO CABLE RAILING FOR OPEN TREAD STAIRS DN 9RDN 9RSTAIR INFO: TREAD : 12" RISER : 6-7/8" CABLE RAILING; SEE SCHEDULES FOR SELECTION TILE ON DITRA XL; BUILD UP FLOOR AS REQ'D TO FLUSH 3/8" TILE WITH 1-1/2" TILE TREAD 9'-71/2"7'-31/8" 3'-103/4"2'-9"3/4" 3'-11"3/4" 4'-03/4"3/4"1/2"4'-01/2"4'-11/2"PACK OUT WALL AS REQ'D AND ALIGN WITH WALL ABOVESUBFLOOR TO SUBFLOORSUBFLOOR TO SUBFLOORFLOOR PLAN - CLOSED TREAD STAIR (VIEWED FROM FIRST FLOOR) 3 A5.52 4 A5.524'-9"STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO.; TYP. OF 6 TILE ON WARMBOARD ON MODULE SUBFLOOR AND FRAMING STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 2x NAILED OVER DRYWALL TO STUDS PERIMETER OF LANDING TO BE SAME THICKNESS AND MATERIAL AS FINISH STRINGER; PAINTED WHITE SITE BUILT LANDING; SEE ENLARGED DETAIL FOR ADDITIONAL INFO. STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO. STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 2x NAILED OVER DRYWALL TO STUDS STAIR TREAD -STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 1x FINISH STRINGER; PAINTED WHITE STAIR RISER - 3/8" THICK STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER TILE ON DITRA XL; BUILD UP FLOOR AS REQ'D TO FLUSH 3/8" TILE WITH 1-1/2" TILE TREAD DRYWALL FINISH AT STAIR RISER AND TREAD; USE TEAR AWAY BEAD OR SIMILAR TO ACHIEVE PROPER FINISH WRAP RAILING AND CONNECT TO CABLE RAILING FOR OPEN TREAD STAIRS WRAP RAILING AND CONNECT TO CABLE RAILING FOR OPEN TREAD STAIRS DN 8RSTAIR INFO TREADS : 11-1/4" RISERS : 7-1/4"DN 8ROPEN TREAD STAIR RISERGOING UP; NOT SHOWNWALL MOUNTED HANDRAIL W/ BRACKETS; SEE SCHEDULE FOR SELECTIONS CABLE RAILING; SEE SCHEDULES FOR SELECTION 4'-01/2" 4'-11/2" 1/2" 4'-03/4" 3/4" 21/2" 3'-61/4" 31/4" 2" 31/4" 3'-61/4" 21/2" 8'-33/8" NO MC DW AT THIS WALL; LC PACKOUT AND ALIGN WITH MODULE BELOW FOR PLUMB DRYWALL INSTALLATION ALIGN BASEMENT WALL WITH MODULE WALLS ABOVE FOR PLUMB DRYWALL INSTALLATION DRYWALL TO STUD; LC TO ALIGN MODULE WALL , PACK OUT AS REQ'D, THEN DRYWALL ENGINEERED WOOD FLOORING ON WARMBOARD ON MODULE SUBFLOOR STAIR TREAD - 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION; WRAPPED IN EWP STAIR STRINGER - 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE CABLE RAILING; SEE SCHEDULES FOR SELECTION MIMIC STAIR STRINGER W/ 1x POPLAR (RABBITED); PAINTED WHITE FRY REGLET OR APPROVED EQUAL BETWEEN WOOD AND DRYWALL DRYWALL UP TO FRY REGLET PERIMETER OF LANDING TO BE SAME THICKNESS AND MATERIAL AS STRINGER; PAINTED WHITE SITE BUILT LANDING; SEE ENLARGED DETAIL FOR ADDITIONAL INFO. RECESSED FIXTURE; SEE ELECTRICAL PLANS AND SCHEDULES FOR ADDITIONAL INFO TILE ON WARMBOARD ON MODULE SUBFLOOR AND FRAMING STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 2x NAILED OVER DRYWALL TO STUDS TILE ON DITRA XL; BUILD UP FLOOR AS REQ'D TO FLUSH 3/8" TILE WITH 1-1/2" TILE TREAD STAIR TREAD AND RISER TILE TO OVERHANG DRYWALL 1/2" BASE TRIM AROUND LANDING TO MATCH FINISH STRINGER ALONG STAIR; PAINTED WHITE STAIR STRINGER - 1x FINISH STRINGER; PAINTED WHITE SCALE: 1/2" = 1'-0" 1 Open Tread Stair - First Floor A5.51 SCALE: 1/2" = 1'-0" 2 Closed Tread Stair - Lower Level A5.51 SCALE: 1/2" = 1'-0" 3 Transverse Stair Section A5.51 max 4" openings at open risers 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.52 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Enlarged Stair Details Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. 4'-11/2"1/2"91/4" 31/8"5/8" 3/4" 1" 117/8"3/4"1'-3"5/8" 4'-01/4" 5/8"23/8"STAIR TREAD - 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION; WRAPPED IN EWP STAIR STRINGER - 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE PERIMETER OF LANDING TO BE SAME THICKNESS AND MATERIAL AS STRINGER; PAINTED WHITE CABLE RAILING; SEE SCHEDULES FOR SELECTION ENGINEERED WOOD FLOORING ON 3/4" PLYWOOD ON 2x10's @ 16" O.C. FRY REGLET OR APPROVED EQUAL BETWEEN WOOD AND DRYWALL HOLD MICROLAM UP AS INDICATED AND WRAP WITH ENGINEERED WOOD FLOORING TOP AND BOTTOM EDGES OF STRINGER UP TO LANDING AND UP TO SECOND FLOOR MUST ALIGN 1/2" PLYWOOD STRIP ATTACHED TO BOTTOM OF 2x10 FRAMING 1x STRAPPING ATTACHED TO FURRING; RUNNING IN THE OPPOSITE DIRECTION 5/8" DRYWALL; FLUSH W/ BOTTOM OF WOOD 25/8± 41/4"1'-0"3/4" 23/4" 3/4"3/4" 101/2" 3/4"11/ 2 "13 /8"1' -0 3 /4 " 21/2"3'-61/4" 31/4" 4'-0"67/8" ±1" TRANSVERSE STAIR SECTION LONGITUDINAL STAIR SECTION ENGINEERED WOOD FLOORING; WRAP AROUND PARALLAM; RABBIT JOINT ON ALL CORNERS 2.0E PARALLAM PSL 211/16x111/4; RIP AS REQUIRED TO ACHIEVE FINISHED TREAD DIMENSION ROUND OVER STAIR EDGE 1/8" FROM STRINGER TO STRINGER 1-3/4" x 11-1/4" ML, WRAPPED IN 1x POPLAR (RABBITED); PAINTED WHITE CUSTOM U-CHANNEL SCREWED TO STRINGER; U-CHANNEL MORTISED INTO PARALLAM AND SECURED; HOLD U- CHANNEL BACK FROM EDGE TO ALLOW FINISH MATERIAL TO BE NAILED ENGINEERED WOOD FLOORING; WRAP AROUND PARALLAM; RABBITED OPTION 3'-103/4"53/4" 11/2"111/4"71/4"11"71/4"1/4" STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER PERIMETER OF TRIM AT LANDING TO BE SAME THICKNESS AND MATERIAL AS FINISH STRINGER; PAINTED WHITE 2x10 JOISTS @ 16" O.C. W/ 3/4" SUBFLOOR; ADDITIONAL THICKNESS NEEDED AT 3/8" FLOOR TILE; BUILD UP AS REQ'D FOR FLOOR TILE TO BE FLUSH WITH STAIR TREAD TILE STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 2x NAILED TO SPACER; SPACER NAILED TO STUDS STAIR RISER - 3/8" THICK STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER TILE ON DITRA XL; BUILD UP FLOOR AS REQ'D; 3/8" TILE TO BE FLUSH WITH 1-1/2" TILE TREAD DRYWALL FINISH AT STAIR RISER AND TREAD; USE TEAR AWAY BEAD OR SIMILAR TO ACHIEVE PROPER FINISH STAIR LIGHT - LEDme STEP LIGHT; SEE SCHEDULES FOR MODEL NO. STAIR STRINGER - 1x FINISH STRINGER; PAINTED WHITE CABLE RAILING; SEE SCHEDULES FOR SELECTION FRY REGLET OR APPROVED EQUAL BETWEEN TILE AND DRYWALL TILE ON WARMBOARD ON MODULE SUBFLOOR AND FRAMING STAIR STRINGER - 1x FINISH STRINGER; PAINTED WHITE FINISH STRINGER TO CONTINUE UNTIL IT REACHES BASEBOARD HEIGHT (TYP. @ STAIR) 1" 3'-101/2"1" 4'-01/2" 1/2" 3'-11" ALIGN BASEMENT WALL WITH MODULE WALLS ABOVE FOR PLUMB DRYWALL INSTALLATION WALL MOUNTED HANDRAIL W/ BRACKETS; SEE SCHEDULE FOR SELECTIONS STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER DRYWALL FINISH AT STAIR RISER AND TREAD; USE TEAR AWAY BEAD OR SIMILAR TO ACHIEVE PROPER FINISH STAIR RISER - 3/8" THICK STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER STAIR STRINGER - 2x NAILED TO SPACER; SPACER NAILED TO STUDS STAIR TILE TO OVERHANG DRYWALL 1/2" STAIR STRINGER - 1x FINISH STRINGER; PAINTED WHITE CABLE RAILING; SEE SCHEDULES FOR SELECTION STAIR TREAD - 1-1/2" EASED EDGE STONE TILE ON MORTAR BED OVER METAL LATH ON CLEAVAGE MEMBRANE ON 3/4" PLYWOOD GLUED AND NAILED TO 2x STRINGER SCALE: 1 1/2"= 1'-0" 1 Open Tread Stair at Landing A5.52 SCALE: 1 1/2"= 1'-0" 2 Open Tread Stair thru Stringer A5.52 SCALE: 1 1/2"= 1'-0" 3 Closed Tread Stair at Landing A5.52 SCALE: 1 1/2"= 1'-0" 4 Closed Tread Stair at Landing A5.52 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A5.53 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Drawing: Interior Details Scale: 1 1/2"= 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: LC NOTES APPEAR IN GRAY BOXES, FACTORY NOTES ARE WITHOUT BOXES. BASE CABINET, SEE INTERIOR ELEVATION DRAWINGS AND SPECIFICATIONS. COUNTERTOP, SEE INTERIOR ELEVATION DRAWINGS AND SPECIFICATIONS. ATTACH WITH EPOXY ADHESIVE PER MANUFACTURER RECOMMENDATIONS. ALWAYS IN LC SCOPE BASE CABINETRY, SEE INTERIOR ELEVATION DRAWINGS AND SPECIFICATIONS. END PANEL or WATERFALL BEYOND SUBFLOORING FINISHED FLOORING CONTINUES UNDER CABINETS OR SAME HEIGHT PLYWOOD. SEE SPECIFICATIONS END PANEL TO MATCH CABINETRY. END PANEL TO MATCH CABINETRY. 2X4 @16" O.C. RIPPED 1X6 TOE KICK. SEE SCHEDULES FOR FINISH. BASE CABINETRY, SEE INTERIOR DRAWINGS, SPECIFICATIONS, AND SCHEDULES. COUNTERTOP WITH EASED EDGES AND MITERED CORMERS, SEE INTERIOR ELEVATION DRAWINGS AND SPECIFICATIONS. ATTACH WITH EPOXY ADHESIVE PER MANUFACTURER RECOMMENDATIONS. ALWAYS IN LC SCOPE 1x6 HARDWOOD TOE KICK RIPPED TO 4" HIGH. SEE SCHEDULES FOR INFORMATION ON FINISH. CABINETRY PANELS. SEE INTERIOR DRAWINGS, SPECIFICATIONS, AND SCHEDULES FOR MORE INFORMATION ON DIMENSIONS AND FINISH. FINISHED FLOORING. SEE INTERIOR DRAWINGS, SPECIFICATIONS, AND SCHEDULES. WARM BOARD® S WITH HYDRONIC PIPING A A PLAN DETAIL SECTION A-A NOTE: OUTLET BOX LOCATION TYPICAL DETAIL IS IN SIDE OF WATERFALL AT STUS WALL. SEE ELECTRICAL PLANS AND KITCHEN ELEVATIONS. FRONT (CABINET DOOR SIDE) BACK NOTE: SEE INTERIOR ELEVATION PLANS & SPECS FOR SCOPE CLARIFICATION NOTE: SEE INTERIOR DRAWINGS, SPECS, AND SCHEDULES FOR SCOPE CLARIFICATION BOX DEPTH TYP SCALE: 1 1/2"= 1'-0" 1 Waterfall Countertop A5.53 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A6.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Window Schedule Drawing: Window Schedule Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: Home Story BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level BSMT/Garden Level First Floor First Floor First Floor ID 104.1 (DR)(t) 105.1 (TT/FX) 105.2 (TT/FX) 106.1 (TT)(t) 106.2 (TT/FX)(E) 111.1 (FX/TT)(E) 116.1 (FX/TT) 120.1 (TTd) 120.2 (TT/FX/TT) 122.1 (DR)(t) 201.1 (DR/FX)(t) 202.1 (TT/FX/FX)(t) 202.2a (TT/FX)(t) View from Inside (t)3'-63/4"2'-5" (E) 3'-65/8"2'-51/8" (E) (t) (t)(t) (t) (t) (t) W/D Nominal Sill Height 0' 3'-6" 3'-6" 3'-6" 3'-2" 3'-2" 3'-6" 0'-7 1/2" 3'-7 1/2" -0'-4 1/2" 0'-1" 0' 0'-1" W/D Opening Surface Area 23.89 34.83 18.33 11.00 28.00 28.00 38.50 22.22 44.00 23.33 64.63 74.42 24.81 W/D Nominal Head Height 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-2" 7'-3 1/2" 7'-3 1/2" 6'-7 1/2" 7'-11" 7'-10" 7'-11" U-value .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 .17 Unit Dimensions 3'-4"×7'-2" 9'-6"×3'-8" 5'×3'-8" 3'×3'-8" 7'×4' 7'×4' 10'-6"×3'-8" 3'-4"×6'-8" 12'×3'-8" 3'-4"×7' 8'-3"×7'-10" 9'-6"×7'-10" 3'-2"×7'-10" Wallhole Dimensions 3'-5"×7'-3" 9'-7"×3'-9" 5'-1"×3'-9" 3'-1"×3'-9" 7'-1"×4'-1" 7'-1"×4'-1" 10'-7"×3'-9" 3'-5"×6'-9" 12'-1"×3'-9" 3'-5"×7'-1" 8'-4"×7'-11" 9'-7"×7'-11" 3'-2 1/2"×7'-11" WINDOW SCHEDULE Home Story First Floor First Floor First Floor First Floor First Floor First Floor First Floor First Floor First Floor First Floor First Floor First Floor ID 202.2b (FX)(t) 202.3a (FX)(t) 202.3b (TT/FX)(t) 203.1 (LS)(t) 203.2(TT/FX/TT) 204.1 (LS)(t) 205.1 (FX/TT) 206.1 (FX) 208.1 (FX) 209.1 (TT/FX/FX)(t) 209.2 (TT)(t) 209.3 (LS)(t) View from Inside (t) (t) (t) VIEW FROM OUTSIDE (t) (t) VIEW FROM OUTSIDE (t) (t) (t)(t) (t) (t)(t) W/D Nominal Sill Height 0'-1" 0' 0' 0'-1/4" 4'-6" 1'-3" 3'-11" 1'-10" 6'-5" 0'-1" 1'-3" 1'-3" W/D Opening Surface Area 57.44 58.06 25.07 84.22 28.47 73.33 33.33 49.81 8.94 74.42 20.00 53.33 W/D Nominal Head Height 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" 7'-11" U-value .16 .16 .17 .17 .17 .17 .17 .16 .16 .17 .17 .17 Unit Dimensions 7'-4"×7'-10" 7'-4"×7'-11" 3'-2"×7'-11" 10'-8"×7'-10 3/4" 8'-4"×3'-5" 11'×6'-8" 8'-4"×4' 8'-2 1/4"×6'-1" 5'-11 1/2"×1'-6" 9'-6"×7'-10" 3'×6'-8" 8'×6'-8" Wallhole Dimensions 7'-4 1/2"×7'-11" 7'-4 1/2"×8' 3'-2 1/2"×8' 10'-9"×7'-11 3/4" 8'-5"×3'-6" 11'-1"×6'-9" 8'-5"×4'-1" 8'-3 1/4"×6'-2" 6'-1/2"×1'-7" 9'-7"×7'-11" 3'-1"×6'-9" 8'-1"×6'-9" WINDOW SCHEDULE Home Story First Floor First Floor Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor ID 211.1 (FX)(t) 211.2 (TT FX)(t) 301.1 (FX/FX)(t) 302.1 (LS)(t) 303.1 (FX/FX) 303.2 (FX/FX) 303.3 (FX) 304.1 (TT/FX)(t) 304.2 (FX/TT/FX)(E)(t) 307.1 (FX/TT/FX)(E)(t) 307.2 (TT/FX)(t) 310.1 (TT/FX/FX)(t) View from Inside (t) (t) (t) (t) (t) (t)(t) (t) MULLED (t) (t) MULLED (t) (t) (t) 4'-15/8"2'-9" (t) (t) (E) 4'-15/8"2'-9" (t) (t) (E) (t) (t)(t) W/D Nominal Sill Height 1'-2" 0'-1" 0'-1" 0'-1" 0'-1" 0' 0'-1" 0'-1" 0'-1" 0'-1" 0'-1" 0'-1" W/D Opening Surface Area 40.14 23.50 61.88 80.67 71.25 78.75 78.75 22.50 62.50 62.50 22.50 71.25 W/D Nominal Head Height 7'-10" 7'-11" 7'-7" 7'-7 3/4" 7'-7" 7'-6" 7'-7" 7'-7" 7'-7" 7'-7" 7'-7" 7'-7" U-value .16 .17 .17 .17 .16 .16 .16 .17 .17 .17 .17 .17 Unit Dimensions 6'-1/4"×6'-8" 3'×7'-10" 8'-3"×7'-6" 10'-8"×7'-6 3/4" 9'-6"×7'-6" 10'-6"×7'-6" 10'-6"×7'-6" 3'×7'-6" 8'-4"×7'-6" 8'-4"×7'-6" 3'×7'-6" 9'-6"×7'-6" Wallhole Dimensions 6'-1 1/4"×6'-9" 3'-1"×7'-11" 8'-4"×7'-7" 10'-9"×7'-7 3/4" 9'-7"×7'-7" 10'-7"×7'-7" 10'-7"×7'-7" 3'-1"×7'-7" 8'-5"×7'-7" 8'-5"×7'-7" 3'-1"×7'-7" 9'-7"×7'-7" WINDOW SCHEDULE Home Story Second Floor Second Floor Second Floor Second Floor Second Floor Second Floor ID 310.2 (TTd)(E)(t) 310.3 (FX/FX)(t) 311.1 (FX) 311.2 (TT FX)(t) 313.1 (FX) 314.1 (FX) View from Inside 7'-11/4"2'-73/4" (t) (E) (t) (t) W/D Nominal Sill Height 0'-1" 2'-6" 2'-6" 0'-1" 6'-1" 0'-1" W/D Opening Surface Area 22.50 40.67 30.61 22.50 8.94 61.41 1,865.20 sq ft W/D Nominal Head Height 7'-7" 7'-7" 7'-7" 7'-7" 7'-7" 7'-7" U-value .17 .16 .16 .17 .16 .16 Unit Dimensions 3'×7'-6" 8'×5'-1" 6'-1/4"×5'-1" 3'×7'-6" 5'-11 1/2"×1'-6" 8'-2 1/4"×7'-6" Wallhole Dimensions 3'-1"×7'-7" 8'-1"×5'-2" 6'-1 1/4"×5'-2" 3'-1"×7'-7" 6'-1/2"×1'-7" 8'-3 1/4"×7'-7" WINDOW SCHEDULE Notes: Unilux Aluminium Clad Wood: Exterior Color: RAL 8022 Interior Color: Pine, Antique White Exterior Handle #7030 (1000 cm straight bar - Brushed Stainless Steel) Interior Handle #2007 Brushed Stainless steel All glass is clear unless otherwise noted. All window sills are 3.5" (90mm) deep, except where noted in the Window schedule above. All window units include 1.25" sill extenders. The sill extenders are included in the unit dimension. All windows are to include aluminum window sills, color to match exterior frame. Loose-ship for LC install. All doors are to include required thresholds. All operable windows include insect screens where available by Unilux. Required door thresholds are delivered with door and are included in the unit dimension. Refer also to eD Standard window and door details. HINGE SIDE (German representation) LOCK SIDE (German representation) WINDOW DESIGNATIONS (t) DESIGNATES SAFETY GLASS og DESIGNATES OBSCURED GLAZING (E) DESIGNATES EGRESS UNIT FX DESIGNATES FIXED UNIT TT DESIGNATES TILT/TURN UNIT TD DESIGNATES FULL GLASS DOOR LS DESIGNATES LIFT/SLIDE UNIT T DESIGNATES TILT UNIT 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A6.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Door Schedule Drawing: Door Schedule Scale: 3" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DOOR SCHEDULE ID 101.1 102.1 105.1 106.1 106.2 107.1 107.2 110.1 111.1 111.2 112.1 112.2 113.1 114.1 115.1 116.1 116.2 117.1 119.1 120.1 122.2 122.3 122.4 123.1 203.2 207.1 207.1 208.1 210.1 211.1 211.2 211A.1 304.1 305.1 306.1 306.2 307.1 308.1 309.1 309.2 310.1 311.1 311.2 311A.1 TYPE A A A A D B F A A D B F A A A A B B A A E E E A G A C A A B F F A B A F A B A F A B F F W 2'-8" 3'-0" 3'-0" 2'-8" 5'-0" 2'-6" 2'-51/2" 2'-8" 2'-8" 5'-0" 2'-6" 2'-51/2" 3'-0" 3'-0" 3'-0" 2'-8" 2'-0" 2'-4" 2'-8" 2'-8" 9'-0" 9'-0" 9'-0" 3'-0" 6'-0" 2'-6" 3'-4" 2'-8" 3'-0" 3'-0" 2'-11" 2'-11" 2'-8" 2'-6" 2'-8" 2'-51/2" 2'-8" 2'-6" 2'-8" 2'-51/2" 3'-0" 3'-0" 2'-11" 2'-11" HT 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 6'-5" 7'-0" 7'-0" 7'-0" 7'-0" 6'-5" 7'-0" 7'-0" 6'-8" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-6" 7'-6" 7'-6" 6'-8" 7'-31/2" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 6'-111/2" 6'-5" 7'-0" 7'-0" 7'-0" 6'-5" 7'-0" 7'-0" 7'-0" 6'-5" 7'-0" 7'-0" 6'-111/2" 6'-5" THK 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-01/2" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-01/2" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/8" 0'-13/8" 0'-13/8" 0'-13/4" 0'-01/2" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-13/4" 0'-01/2" 0'-01/2" 0'-13/4" 0'-13/4" 0'-13/4" 0'-01/2" 0'-13/4" 0'-13/4" 0'-13/4" 0'-01/2" 0'-13/4" 0'-13/4" 0'-01/2" 0'-01/2" MAT WD WD WD WD WD WD G WD WD WD WD G WD WD STEEL WD WD WD WD WD STEEL STEEL STEEL WD G WD WD WD WD WD G- Frost G WD WD WD G WD WD WD G WD WD G- Frost G FINISH P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 P-03 PC BLACK PC BLACK PC BLACK P-03 P-03 P-03 P-03 - - P-03 P-03 P-03 - P-03 P-03 P-03 - P-03 P-03 - - CORE SC SC SC SC SC SC SC SC SC SC SC SC INSUL SC SC SC SC SC INSUL INSUL INSUL SC SC SC SC - - SC SC SC - SC SC SC - SC SC - - GLZ - - - - - - FULL - - - - FULL - - - - - - - - SECT 3 GL- GL-GL-GL SEE SPEC SEE SPEC - FULL - - - - - FULL FULL - - - FULL - - - FULL - - FULL FULL VENT GRILL - - - VG1 - - VG2 VG1 - - VG2 - - VG1 VG1 - - - - - - - - - VG1 - - - VG1 - - - - - - - HAND L R R R - - L R R - - R R L L R - - L L - - - L R L L L L - R R L - L L L - L R R R R R FRAME W 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-0" 0'-0" 0'-0" 0'-03/4" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/4" 0'-03/4" 0'-03/8" 0'-03/8" THK 0'-43/4" 0'-43/4" 0'-63/4" 0'-63/4" 0'-43/4" 0'-63/4" 0'-0" 0'-43/4" 0'-63/4" 0'-43/4" 0'-63/4" 0'-0" 0'-63/4" 0'-43/4" 0'-43/4" 0'-43/4" 0'-63/4" 0'-63/4" 0'-43/4" 0'-43/4" 0'-0" 0'-0" 0'-0" 0'-43/4" 0'-0" 0'-43/4" 0'-43/4" 0'-43/4" 0'-43/4" 0'-63/4" 0'-0" 0'-0" 0'-43/4" 0'-63/4" 0'-43/4" 0'-0" 0'-43/4" 0'-63/4" 0'-43/4" 0'-0" 0'-43/4" 0'-63/4" 0'-0" 0'-0" DETAILS HEAD A A A A C B A A C B A A A A B B A A A A C A A A A A A A A A A A JAMB A A A A C B A A C B A A A A B B A A A A C A A A A A A A A A A A SILL A A A A C B A A C B A A A A B B A A A A C A A A A A A A A A A A RATING - 20 MIN 20 MIN - - - - - - - - - - - 20 MIN - - - - - - - - 20 MIN - - - - - - - - - - - - - - - - - - - - HW SET 1 1 TBD if 1 1 2 3 4 1 1 2 3 4 1 1 1 1 3 3 1 1 - - - 1 5 1 2 1 1 3 4 4 1 3 1 4 1 3 1 4 1 3 4 4 LOCK FUNCT PGE PGE PCY with DB PCY DMY PCY - PGE PCY DMY PCY - PCY PCY PCY with DB PCY PCY PCY PGE PGE PCY with DB - PCY DMY PCY PCY PCY - - PCY PGE PCY - PCY PGE PCY - PCY PGE - - STOP W H H W - - H H - - W W W W - - - H H W - F - W - H - W - H - W - F - NOTES UNDERCUT DOOR 1" KEYED SEPERATE, PROVIDE HINGE CLOSERS AND DEADBOLTS ON EACH SIDE INSTALL 2 LOUVERS EACH 3" FROM TOP & BOTTOM OF DOOR. 60 SQ IN MIN LOUVER OPENING THERMA-TRU A100, PROVIDE WEATHER STRIP, HINGE CLOSERS CLOPLAY MODERN STEEL #9131 w/ LIFTMASTER 8500 SIDE-MOUNT INCL BATTERY BACK-UP SEE ABOVE SEE ABOVE THERMA-TRU A100, PROVIDE WEATHER STRIP, HINGE CLOSERS CUSTOM GLASS WINE COOLER DOOR WITH GASKETS VIEW Group Type A A B C D E F F F G Material STEEL WD WD WD WD STEEL G G- Frost G G DOOR TYPES 1/4" 21/2"13/4"1/4" 21/2" 5/16"13/4" 5/16" 1/4" 21/2" R.O. WIDTH: 2x DOOR WIDTH + 1"3/4"63/4" 3/4" 5/8" 51/2" 5/8"5/8" 51/2" 5/8"63/4"63/4"1/4" 21/2"PRE-HUNG DOOR UNIT AND HARDWARE (DOOR UNIT INCLUDES DOOR, FRAME, AND HINGES) SUPPLIED AND INSTALLED BY MC. SEE DOOR SCHEDULE. INSTALL 1x3 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. INSTALL BASE TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION, AND BASE DETAILS IN SECTION 60. 1x3 PAINTED WOOD TRIM. SEE FINISH SCHEDULE FOR SELECTION. PRE-HUNG DOOR UNIT AND HARDWARE (DOOR UNIT INCLUDES DOOR, FRAME, AND HINGES) SUPPLIED AND INSTALLED BY MC. SEE DOOR SCHEDULE. INSTALL 1x3 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. PRE-HUNG DOOR UNIT AND HARDWARE (DOOR UNIT INCLUDES DOOR, FRAME, AND HINGES) SUPPLIED AND INSTALLED BY MC. SEE DOOR SCHEDULE. INSTALL 1x3 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. INSTALL BASE TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION, AND BASE DETAILS IN SECTION 60. JOHNSON 200SD SERIES BYPASS SLIDING DOOR HARDWARE (SIZED PER DOOR, 400# DOOR MAX CAPACITY) BYPASS SLIDING DOORS. SEE DOOR SCHEDULE. INSTALL 1x3 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. JOHNSON 2135 SERIES BYPASS FLOOR GUIDE FINISHED FLOORING INSTALL 1x3 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. NON-LOAD BEARING HEADER; IF LOAD BEARING WALL, SEE STRUCTURAL SHEETS FOR HEADER SIZE JOHNSON 2000 SERIES POCKET DOOR HARDWARE (SIZED PER DOOR, 400# DOOR MAX CAPACITY) INSTALL RIPPED 1X6 PAINTED WOOD TRIM AS SUPPLIED BY MC. SEE FINISH SCHEDULE FOR SELECTION. JAMB B @ END DRYWALL FINISH; SEE FINISH SCHEDULE FOR SELECTION INTERIOR DOOR; SEE DOOR SCHEDULE FOR SELECTION, FINISH, & HARDWARE 5/8" DRYWALL; INSTALLED IN FIELD JAMB B @ POCKET DRYWALL FINISH; SEE FINISH SCHEDULE FOR SELECTION INTERIOR DOOR; SEE DOOR SCHEDULE FOR SELECTION, FINISH, & HARDWARE 5/8" DRYWALL; INSTALLED IN FIELD 2x4 POCKET DOOR SPLIT STUDS R.O. WIDTH: 2x DOOR WIDTH + 1" 1x POPLAR WOOD JAMB (PAINTED) 1x3 POPLAR WOOD TRIM PIECE (PAINTED) 1x3 POPLAR WOOD TRIM PIECE (PAINTED) FINISHED SPLIT HEADER (PAINTED) INTERIOR DOOR; SEE DOOR SCHEDULE FOR SELECTION, FINISH, & HARDWARE JAMB A INTERIOR PARTITION WALL SOUND INSULATION MAY OCCUR; SEE FLOOR PLANS FOR INFORMATION NON-LOAD BEARING HEADER; IF LOAD BEARING WALL, SEE STRUCTURAL SHEETS FOR HEADER SIZE 5/8" DRYWALL; SEE SPECS FOR FINISH LEVEL HEAD A JAMB C 2x4 INTERIOR PARTITION WALL NON-LOAD BEARING HEADER; IF LOAD BEARING WALL, SEE STRUCTURAL SHEETS FOR HEADER SIZE 5/8" DRYWALL; SEE SPECS FOR FINISH LEVEL SILL C HEAD C CLOSET SIDE. ROOM SIDE. 2x4 INTERIOR PARTITION WALL 5/8" DRYWALL; SEE SPECS FOR FINISH LEVEL JACK AND KING STUD FRAMING IN MODULE WALL. INTERIOR PARTITION WALL. SEE PLANS AND FINISH SCHEDULE. JACK AND KING STUD FRAMING IN MODULE WALL. INTERIOR PARTITION WALL. SEE WALL TYPES AND FINISH SCHEDULE. SCALE: 3" = 1'-0" DOOR SCHEDULE KEY: MATERIAL: W - WOOD G - GLASS FINISH: WV- FSC WOOD VENEER, LACQUER P-XX PAINTED, SEE FINISH SCHEDULE FOR COLOR DESIGNATION. CORE: SC - SOLID CORE WOOD MDF - ACS CERITIFIED MDF MC - NON-COMBUSTIBLE MINERAL CORE INSUL - INSULATED TRIM: STD - STANDARD 1X3 POPLAR, SQUARE. SUPPLY BY MC, INSTALL BY LC. LOCK FUNCTION: PGE - PASSAGE LOCK PCY - PRIVACY LOCK DMY - DUMMY TRIM DB - DEAD BOLT HARDWARE SETS GROUP 1: VALLI VALLI: H416 GARNET SERIES, 32D SATIN STAINLESS STEEL DEADBOLT (IF NOTED): 101 RPS PLAIN STAINLESS STEEL DEADBOLT DOUBLE CYLINDER GROUP 2: DELTANA FLUSH PULL: FP7178U26D, (1) PER DOOR, IN BRUSHED CHROME GROUP 3: EMTEK POCKET DOOR MORTISE- MODERN RECTANGULAR IN SATIN NICKEL. PASSAGE 2114, PRIVACY 2115 GROUP 4: CRL: GENS6CH POLISHED CHROME GENEVA SHOWER KNOB AND HINGE SET. CRL: MT24X24CH, MT SERIES BACK-TO_BACK TOWEL BAR, POLISHED CHROME GROUP 5: CRL: SRCAR01, SENIOR CARDIFF TOP & BOTTOM MOUNT PIVOT HINGES, POLISHED CHROME. CRL: OR18CH SINGLE SIDED TOWEL BAR-MOUNT VERTICALLY AS PULL STANDARD HINGES FOR SWING DOORS: 1 1/2 PR PER DOOR PANEL, SCHLAGE SC3P1020F619E IN BRUSHED NICKEL STANDARD HARDWARE FOR POCKET DOORS: JOHNSON 2000 SERIES HEAVY DUTY POCKET DOOR FRAME (400# CAPACITY) SIZED PER WALL AND DOOR AT EACH LOCATION. BYPASS SLIDING DOORS TO HAVE STANDARD **** HARDWARE, WITH EXCEPTION OF DOOR PULLS, SEE ABOVE. STOPS: W- WALL STOP, DELTANA BDS450U26D IN BRUSHED CHROME F - FLOOR STOP, DELTANA UFB5000U26D IN BRUSHED CHROME H - HINGE STOP, DELTANA HP70U26D IN BRUSHED CHROME ** BYPASS SLIDING DOORS IN MODULES WILL HAVE FRAME INSTALLED BY MC, DOOR PANELS WILL BE SHIPPED LOOSE TO BE HUNG BY LC. VENTILATION GRILLS: VG1: RENSON INVISIDO 469 WHITE, WIDTH OF DOOR LEAF VG2: ANEMOSTAT AFDL STEEL LOUVER, GREY PRIMER FOR LC PAINTING FREE AIR FLOW IS 50% OF DOOR CUT OUT 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A6.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Finish Schedule Drawing: Finish Schedule Scale: 1:1.11 CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: INTERIOR FINISH SCHEDULE Floor BSMT/Garden Level First Floor Second Floor Room Number 100 101 102 103 104 105 106 107 108 110 111 112 113 114 115 116 117 119 120 121 122 123 201 202 203 204 205 206 207 208 210 211 211A 212 - 301 302 304 305 306 306A 307 308 309 309A 310 311 311A 312 313 314 Room Name PATIO ELEVATOR FOYER MECH RM STORAGE FOYER LIVING BEDROOM 1 BATH HALL LAUNDRY BEDROOM 2 BATH MECH RM BATH HALL OFFICE MUD ROOM MEDIA ROOM GYM SAUNA GARAGE STORAGE DECK FOYER LIVING ROOM KITCHEN DINING PANTRY STAIR HALL WC MASTER BED MASTER BATH STEAM SHW WIC DECK VOID FOYER GALLERY BEDROOM 3 WIC BATH SHOWER BEDROOM 4 WIC BATH SHOWER MASTER BED 2 MASTER BATH STEAM SHW WIC LAUNDRY STAIR Flooring PAVERS S-1 S-1 CONC-2 S-1 S-1 EWP CPT-1 S-1 EWP-1 S-1 CPT-1 S-1 CONC-2 S-1 S-1 CPT-1 S-1 CPT-1 RF-1 CONC-1 CONC-1 CONC-1 Dasso S-1 EWP EWP EWP EWP S-1 S-1 S-1 EWP S-1 T-2 EWP Dasso CPT-? CPT-? CPT-? CPT-? S-1 T-2 CPT-? CPT-? S-1 T-2 CPT-? S-1 T-2 CPT-? S-1 EWP Base Trim WD/P-3 WD/P-3 - WD/P-3 WD/P-3 WD/P-3 WD/P-3 S-1 WD/P-3 WD/P-3 WD/P-3 S-1 - S-1 WD/P-3 WD/P-3 WD/P-3 WD/P-3 WD/P-3 - - - WD/P-3 WD/P-3 WD/P-3 WD/P-3 WD/P-3 WD/P-3 WD/P-3 S-1 WD/P-3 WD/P-3 T-2 WD/P-3 WD/P-3 WD/P-3 WDWD/ P-3 WD/P-3 S-1 T-2 WD/P-3 WD/P-3 S-1 T-2 WD/P-3 S-1 T-2 WD/P-3 WD/P-3 WD/P-3 Window Sills & Door Trim WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 - WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 - WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 WSP/P-3 - WSP/P-3 WSP/P-3 WSP/P-3 - WSP/P-3 WSP/P-3 - WSP/P-3 WSP/P-3 - Predominate Wall Finish N S E W Ceiling P-1 P-1 - P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 - P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 T-2 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 T-2 P-1 P-1 P-1 Height 0.00' 9.00' 7.67' 8.46' 0.00' 8.08' 7.67' 7.67' 7.67' 7.67' 7.67' 7.67' 7.67' 7.67' 7.67' 8.08' 8.63' 8.08' 8.50' 7.67' 8.63' 8.50' 8.50' 0.00' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 8.42' 0.00' 0.00' 8.08' 8.08' 8.08' 8.08' 8.08' 8.08' 8.08' 8.08' 8.08' 8.08' 8.48' 8.48' 8.48' 8.48' 8.08' 8.08' Cabinetry - - - - Counter- top - - - - CT-? CT-? CT-? - - CT-? - CT-? - - - CT-? - - - - - - CT-? CT-? CT-? - - CT-? - CT-? CT-? - - - - - - - CT-? - - - CT-? - - CT-? - - CT-? - Notes See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations See interior elevations 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: A6.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Appliance Schedule Drawing: Appliance Schedule Scale: 1:1.11 CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: Equipment: Appliances Location BSMT/Garden Level, LAUNDRY, 110 BSMT/Garden Level, LIVING, 105 BSMT/Garden Level, SAUNA, 121 First Floor, KITCHEN, 203 First Floor, MASTER BATH, 211 Second Floor, LAUNDRY, 313 Second Floor, MASTER BATH, 311 Full Element ID Clothes Dryer Clothes Washer 15" Electric Cooktop 18" Dishwasher 24" Microwave 24" Refrigerator 24" Single Oven Vent Hood Sauna 15" Single Induction Cooktop 24" Dishwasher, integrated 24" Dishwasher, integrated 30" Built in Coffee System 30" Combi-Steam Wall Oven 30" Microwave Oven 30" Refrigerator, integrated 30" Warming drawer Range hood Steam Shower Control & Steamhead Steam Shower Generator Clothes Dryer Clothes Washer Steam Shower Control & Steamhead Steam Shower Generator QTY 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1 1 MFG Electrolux Electrolux KitchenAid Bosch, 800 Series Panasonic Bosch Whirlpool Zephyr Golden Design Inc. Bosch Bosch Bosch Bosch Bosch Bosch Sub Zero Bosch Zephyr Mr. Steam Mr. Steam Electrolux Electrolux Mr. Steam Mr. Steam Item Number EFMG517S TT EFLS517S TT KECC056RBL ProLine SPV68U53UC NNSN773SS B10CB80NVW WOS11EM4EB AK8400AS GDI-7689-01 NIT8666UC SHV88PW53N SHVM98W73N BCM8450UC HBLP451LUC HMC80152UC IT-30CI-LH & IT-30CI-RH HWD5051UC ALU-E43ASX MSBUTLER 1RD-PC MS400EC1X with iTempoPlus Control EFMG517S TT EFLS517S TT MSBUTLER 1RD-PC MS400EC1X with iTempoPlus Control Color/Finish Black Panel ready Stainless Steel Black Stainless Steel Red Cedar Panel Ready Panel Ready Stainless Steel Stainless Steel Stainless Steel Panel Ready Stainless Steel Brushed Stainless Steel Polished Chrome Polished Chrome Size WxDxH 27"x31.5"x38 " 27"X32" X38" 16.25"x21.25 "x2.875" 17.75"x22.5" x32.125" 22"x21.5"x 69.75" 24" 20.5"x 11"x9.5" 79"x72"x83" 23"x22.5"x33 .375" 23"x22.5"x33 .375" 30" 30"x80"x24" 30" 43.375"x27.5 "x ±14" 27"x31.5"x38 " 27"X32" X38" Supplied By: LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC Installed By: LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC Notes Gas, Vented Built-in Install LC provided panels Counter Depth 180-290 CFM. 6" duct Touch screen control panel requires 110V/15AMP receptacle. 7.5KW stove works on 240V/ 30AMP Install MC provided panels and handles Install MC provided panels and handles MC cabinetry to allow ventilation per manufacturer **?** MC to provide plumbing per manufacturer **?** Install MC provided panels and handles Provide CB 1290A; 290 CFM Blower with 6" round duct to exterior Includes: iTempoPlus Control, iTempo Aromasteam Steamhead, Steamlinx Module & Mobile App, Autoflush, Condensation pan MC to install required wiring and plumbing to steam shower. 9KW, 240V, 1PH, Steam bath generator with express steam Gas, Vented Includes: iTempoPlus Control, iTempo Aromasteam Steamhead, Steamlinx Module & Mobile App, Autoflush, Condensation pan MC to install required wiring and plumbing to steam shower. 9KW, 240V, 1PH, Steam bath generator with express steam 10/11/18 10/11/18 10/11/18 Lot 2 COMMON PARCEL 0.458 acres 5044 Lot 1 Lot 3 Lot 5 Lot 6 Lot 4 MAIN GORE DRI V E SOU T H 5 0 ' P u b l i c Ri g h t-o f-Wa y 8586 8588 859 0 8592 8 5 9 4 8596 8598 8584 S MARCIN ENGINEERING LLCGRAPHIC SCALE (IN FEET) 1 inch = 10 ft. NOTE: RETAINING WALL DETAIL SHOWN FOR DRAINAGE ILLUSTRATION ONLY. RE: STRUCTURAL ENGINEER FOR MORE RETAINING WALL DETAILS. 10/11/18 Survey-1 of 2 10/11/18 Survey-2 of 2 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES W ork in P rogressRevID ChID Change Name Date 01 - WIP 08 Electrical Changes Work in Progress evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: BSMT Lighting and Switching Plan Drawing: BSMT Lighting and Switching Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: A1 R A1 R A1R A1 R J1A1 R A1 R A1R G1 A1R A1R A1R G3 G3A1R A1 R A3 R J1A1R A1R A3R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1 R E1E1E1 E1 E1 E1DWF 6C P3P2 P3 6C6C R R 6C 6CTDa TA A1 R TG2 P3 6C J1J16CA1 R A1 R A1R A1R A1R A1R 6C6C 6CG2 G2 G2 A1R RM A1 R A1 R A1 R A1 R TDb TDc TB TCG3 A1R A1 R A1 R A1 R 6C R6C F4 6C CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD PROVIDE TELEPHONE LAND LINE TO ELEVATOR. SEE MANUFACTURER SPECS. BOILER BOILER UH 1 Panel BA BATH 114 Ceiling Ht:7.67 BATH 107 Ceiling Ht:7.67 LIVING 105 Ceiling Ht:7.67 FOYER 104 Ceiling Ht:7.67 BEDROOM 1 106 Ceiling Ht:7.67 HALL 108 Ceiling Ht:7.67 BEDROOM 2 111 Ceiling Ht:7.67 GARAGE 122 Ceiling Ht: Varies GYM 120 Ceiling Ht:7.67 BATH 112 Ceiling Ht:7.67 (2) O2 Gen STACKED O2 Gen OFFICE 116 Ceiling Ht:8.50 ***VERIFY HEIGHT VS WINDOW*** HALL 115 Ceiling Ht:7.67' TERMINATE ALL ETHERNET JACKS IN A/V CABINET TERMINATE COAX LINE IN A/V CABINET ***VERIFY DRAIN OR SLOPED PAVERS TO REMOVE SNOW MELT WATER*** PROVIDE CEILING MOUNTED HDMI CABLE TO TERMINATE AT A/V CABINET BOILER MEDIA ROOM 119 Ceiling Ht:8.50 MEDIA ROOM 119 Ceiling Ht:8.92 MUD ROOM 117 Ceiling Ht:8.00 FOYER 101 Ceiling Ht:8.08 MECH RM 113 Ceiling Ht:8.63 MECH RM 102 Ceiling Ht:7.63 ROOF DRAINAGE UP TO LIGHTS AND SWITCH 24" AFF96" AFF42" AFF 42" AFF42" AFF42" AFF 42" AFF42" AFF42" AFF18" AFFLOW VOLTAGE WIRE COPPER NMC WIRE. SEE NOTES FOR MIN. GAUGE SEE MANUFACTURER INFORMATION FOR POWER AND LIGHTING REQUIREMENTS. (OSLO SAUNA)42" AFF 42" AFFWIRELESS RADIO RA 2 CONNECTION BL-25 BL-25 BL-25 BL-25 BL-25 BL-23 BL-23 BL-23 1F-23 BL-23 BL-23 BL-23 BL-23 BA-17 BA-17 BA-17 BA-17 BA-17 BA-17 BA-17BA-17 BA-17 BA-17 UP TO LIGHTS IN SAUNA PEX MANIFOLDSELEC & FA PANELS BL-25 LUNOS e2 BL-23 (HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLECIRCUIT)24" AFF(HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT) 24" AFF 42" AFF 42" AFF BL-23 BL-27 (ALL LUNOS) A3R G1 A1 R J1 M2 M2 M2 6CT 6CGFCI GFCI GFCI GFCI GFCI 42" AFF GFCI (WP/WR) GFCI (WP/WR) GFCI (WP/WR) R24" AFF96" AFF42" AFF42" AFF 42" AFF42" AFF6CCEILING 84" AFF 6CT P G1 42" AFF xx xx H6TJ1 J GFCI GFCI J J CO+SD CO+SD G6G6 G7 G7 G8G8 G6 G6G6G6 xx 42" AFF 84" AFF84" AFFxxxxxxJ J J J J J J JGFCI (WP/WR)GFCI (WP/WR) J T J METER LOCATION ?, VERIFY WITH UTILITY DHW DHW 3#10, 1#10G, 3/4" C DHW BA-17 BA-17 BA-17 BA-17 BL-23 BA-17 BA-17 BA-17 ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 01 - WIP.08 PRICE REVIEW SET 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: BSMT Power Plan Drawing: BSMT Power Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DWF 6C BOILER BOILER UH 1 Panel BA FACP BATH 114 Ceiling Ht:7.67 BATH 107 Ceiling Ht:7.67 LIVING 105 Ceiling Ht:7.67 FOYER 104 Ceiling Ht:7.67 BEDROOM 1 106 Ceiling Ht:7.67 HALL 108 Ceiling Ht:7.67 BEDROOM 2 111 Ceiling Ht:7.67 GARAGE 122 Ceiling Ht: Varies GYM 120 Ceiling Ht:7.67 BATH 112 Ceiling Ht:7.67 (2) O2 Gen STACKED O2 Gen OFFICE 116 Ceiling Ht:8.50 HALL 115 Ceiling Ht:7.67' BOILER MEDIA ROOM 119 Ceiling Ht:8.50 MEDIA ROOM 119 Ceiling Ht:8.92 MUD ROOM 117 Ceiling Ht:8.00 FOYER 101 Ceiling Ht:8.08 MECH RM 113 Ceiling Ht:8.63 MECH RM 102 Ceiling Ht:7.63 ROOF DRAINAGE BL-28 (ALL LUNOS UNITS) BA-9 BA-3 BA-11 BA-2 BA-12,14 BA-8,10 BA-4 BA-6 BA-25 BL-35,37 BA-16,18 BA-20 BA-5 BL-32,34 BA-22PEX MANIFOLDSBL-21 BL-44 BA-7 LUNOS e2 BL-26 GFCI GFCI GFCI GFCI GFCI 42" AFF GFCI (WP/WR) GFCI (WP/WR) GFCI (WP/WR)24" AFF96" AFF42" AFF42" AFF42" AFF42" AFFCEILING 84" AFF 42" AFF J GFCI GFCI J J LCD 42" AFF 84" AFF84" AFFJ J J J J J J JGFCI (WP/WR)GFCI (WP/WR) J T J DHW DHW 3#6, 1#10G, 1" C 3#10, 1#10G, 3/4" C DHW BA-13 BA-1 BA-15 BL-12 BL-6 BL-4 BL-5 BL-1 BL-13 BL-9 BL-7 BL-10 BL-19 BL-20 BL-8 BL-6 BL-4 BL-18 60AS BL-22 60AS 3#6, 1#10G, 1"C BL-24 BL-27 BL-27 BL-27 BL-27 BL-27 BL-27 BL-27 BL-11 (SNOW MELT LOOP PUMPS) BL-2 (DHW RECIRC PUMPS) BL-2 BL-15BL-17 BL-3 BL-16 BL-14 BL-27 ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 5.08 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Floor Lighting and Switching Plan Drawing: First Floor Lighting and Switching Plan Scale: 1/4" = 1'-0", 1/8" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: E1 E1 A1 R A1R A1 R E1 A1 R A1R E1 E1 A1R E1A1R DW DWF R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1 R A1R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1R A1R A1 R A1R A1 R J1 J1 A1 R A1 R A1R A1R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1 R A1 R A1 R A1R A1R A1 R A1R A1 R A1 R A1R F1 F1 A1 R A1R A1R A1 R A1R 6CJ1J1J1A1 R A1R A1R G3G3 A1 R A1 R A1 R RA E2 E2 T1 E2 RF3 6C A1 R E2 T2 T3 CO+SD CO+SD CO RA PANEL 1FMASTER BATH 211 Ceiling Ht:8.50 MASTER BED 210 Ceiling Ht:8.50 KITCHEN 203 Ceiling Ht:8.50 FOYER 201 Ceiling Ht:8.50 WC 208 Ceiling Ht:8.50 WIC 212 Ceiling Ht:8.50 1ST FL LIGHTS BSMT LIGHTS 42" AFF LOW VOLTAGE WIRE COPPER NMC WIRE. SEE NOTES FOR MIN. GAUGE TO ZVC BELOW WIRELESS RADIO RA 2 CONNECTION TO WINE LIGHTING TO LIGHTS ABOVE - B TO LIGHTS ABOVE - A 80" AFF 1F-15 1F-15 1F-15 1F-15 1F-15 1F-15 1F-17 1F-15 1F-15 1F-15 1F-15 1F-13 1F-13 1F-131F-13 1F-13 1F-13 1F-13 1F-13 1F-13 1F-13 1F-13 1F-13 1F-13 1F-15 1F-15 1F-15 1F-23 1F-23 1F-13 1F-13 1F-23MW LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 42" AFF 42" AFF 96" AFF(HEAT CABLE CIRCUIT) 24" AFF (HEAT CABLE CIRCUIT)24" AFF TO SWITCH AND UNIT ABOVE (LAUNDRY) BL-27 (ALL LUNOS) 1F-15 1F-15 1F-15 1F-13WALLOVEN COFFEE F 36" AFF M2 M2 M2 6C M2 M2 M2 M1 M1 M1 M1 M1M1M1 36" AFF36" AFFGFCI42" AFF GFCI 42" AFF GFCI42" AFF GFCI 42" AFF GFCI 42" AFF GFCI 42" AFF/GFCI 42" AFF/GFCI 42" AFF GFCI42" AFF GFCI GFCI (WP/WR) GFCI (WP/WR)GFCI (WP/WR)42" AFF 42" AFF 42" AFF 42" AFF GFCI 42" AFF GFCI6C 6C6C TGFCIR A3R A1 R A1 R F2 A1R 6C6C H696" AFF42" AFF MD 90" AFF MD 90" AFF H66C 6C A1R A1 R 6C6CDA DA 6C H5 GFCI (WP/WR) GFCI (WP/WR)GFCI (WP/WR)42" AFF A1R 6C6C6C6C QT QTH66C 6C 6C 6C 6CH6 80" AFF GFCI (WP/WR)GFCIGFCI GFCI J 24" AFF JGFCI (WP/WR) GFCI (WP/WR) GFCI (WP/WR) MD 90" AFF A1R 6C 6C6C6C 42" AFF 36" AFF 6C 6C6C6C6C6C6C6C6C H66C6C 6C6CGFCI (WP/WR)H5 J J J FOR DOCKING DRAWER OUTLET PROVIDE POWER AND CONTROLS FOR ART LIFT PER MANUFACTURER REQUIREMENTS. PROVIDE POWER TO STEAM SHOWER GENERATOR. SEE MANUFACTURER SPECIFICATIONS. BELOW COUNTERTOP. PROVIDE GROMMET IN COUNTERTOP SPEAKER WIRE MOUNTED UNDER BALCONY. TYP FOR (2) LOCATIONS. PROVIDE 3/4" C TO ROOF FOR HEAT TRACE CIRCUIT AT INTERNAL DOWNSPOUTS. (2F-25) 42" AFF TO LIGHTS ABOVE - C TO LIGHTS ABOVE - D 1F-13 1F-13 2F-13 ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN SWITCH & OUTLET W/ LIGHT ABV LISA J, SWITCHES WERE ELIMINATED. I BELIEVE WE WILL NEED SOME FOR THESE CIRCUITS. WHERE SHOULD THE SWITCHES BE LOCATED? VERIFY ELECTRICAL REQUIREMENTS FOR TIMER/ SWITCHING D D D D 1F-21 ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 5.08 SMI PRICE REVIEW SET 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Floor Power Plan Drawing: First Floor Power Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DW DWF RA PANEL 1FMASTER BATH 211 Ceiling Ht:8.50 MASTER BED 210 Ceiling Ht:8.50 KITCHEN 203 Ceiling Ht:8.50 FOYER 201 Ceiling Ht:8.50 WC 208 Ceiling Ht:8.50 WIC 212 Ceiling Ht:8.50 1F-24 1F-18 1F-201F-40 (COFFEE) 1F-32,34 1F-38 (MW) 1F-12 1F-14 1F-16 1F-10 1F-22 1F-28,30 1F-36 1F-26 1F-6 1F-4 1F-2 1F-11 1F-3 1F-37,39 1F-71F-5 BL-28 (ALL LUNOS UNITS)MWLUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 1F-27 1F-25 1F-1 1F-9 1F-17 (WD)WALLOVEN COFFEE F 36" AFF 36" AFF36" AFFGFCI 42" AFF GFCI 42" AFF GFCI42" AFF GFCI 42" AFF GFCI 42" AFF GFCI 42" AFF/GFCI 42" AFF/GFCI 42" AFF GFCI42" AFF GFCI GFCI (WP/WR)GFCI (WP/WR)GFCI (WP/WR)42" AFF 42" AFF 42" AFF 42" AFF GFCI 42" AFF GFCI GFCI96" AFF42" AFF MD 90" AFF MD 90" AFF GFCI (WP/WR) GFCI (WP/WR)GFCI (WP/WR)42" AFF 80" AFF GFCI (WP/WR)GFCIGFCI GFCI J24" AFF J LCD GFCI (WP/WR) GFCI (WP/WR) GFCI (WP/WR) MD 90" AFF 42" AFF 36" AFFGFCI (WP/WR)J J J PROVIDE POWER AND CONTROLS FOR ART LIFT PER MANUFACTURER REQUIREMENTS. 2#6, 1#16G, 1" C PROVIDE 3/4" C TO ROOF FOR HEAT TRACE CIRCUIT AT INTERNAL DOWNSPOUTS. (2F-25) 1F-8 (ART LIFT) 1F-33,35 60AS 30AS ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN SWITCH & OUTLET W/ LIGHT ABV ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 5.08 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.05 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Second Floor Lighting and Switching Plan Drawing: Second Floor Lighting and Switching Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: A1 R A1 R B B A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1 R A1R A1R A1 R A1R A1R A1R R RF2F2 6C A1R A1R A1R A1R A1R A1 R J1 J1 A1 R A1 R A1R J1 J1 R R RA1R 6CG3G3J1J1J1F2 J1 J1 RM A1 R A1 R A1R A1R A1 R A1R A1 R A1R A1R A1 R A1R T4T5 T6 T7 CO+SD CO+SD CO+SD CO+SD CO+SD 1'-11" 1'-11"PANEL 2FFOYER 301 Ceiling Ht:8.00 MASTER BED 2 310 Ceiling Ht:8.50 MASTER BATH 311 Ceiling Ht:Varies STAIR 314 Ceiling Ht:8.00 BEDROOM 4 307 Ceiling Ht:8.00 BEDROOM 3 304 Ceiling Ht:8.00 GALLERY 302 Ceiling Ht:8.00 BATH 306 Ceiling Ht:8.00 WIC 312 Ceiling Ht:8.50 LAUNDRY 313 Ceiling Ht:8.00 H2-2 H2-2 CG2-1 BATH 309 Ceiling Ht:8.00 VOID - Ceiling Ht:8.00 DN TO LIGHTS AND SWITCH 42" AFF 42" AFF42" AFF42" AFF96" AFFLOW VOLTAGE WIRE COPPER NMC WIRE. SEE NOTES FOR MIN. GAUGE TO SWITCH BELOW - A WIRELESS RADIO RA 2 CONNECTION DN TO SWITCH TO SWITCH BELOW - B TO SWITCH BELOW - D TO SWITCH BELOW - C DN TO LIGHTS AND SWITCH 2F-15 2F-15 2F-15 2F-15 2F-15 2F-15 LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 42" AFF96" AFFTO ZVC BELOW (HEAT CABLE CIRCUIT) IN SOFFIT BELOW CANOPY TO UNIT BELOW M2 M2 M2 B A3 R A3 R A2 R A2 R A2 R A2 R A2R 6C6C 6C 42" AFF42" AFF96" AFF CO+SD E1GFCI (WP/WR)36" AFF 42" AFF 42" AFF 42" AFF 42" AFF6C A3 R 6C 6C A1R A1R P3P36C P36C P36C6C6C 6C6C P3 6C A1 R H5GFCI (WP/WR)GFCI (WP/WR) A1 R 6C 6C6CH66C6CH5 JGFCIGFCIA1R GFCI GFCI A1 R A1R GFCIA1R GFCIGFCIMD MD MD MD A2 R A1 R 42" AFF 36" AFF 6C6C6C 96" AFFJ PROVIDE POWER TO STEAM SHOWER GENERATOR. SEE MANUFACTURER SPECIFICATIONS. PROVIDE WIRING AS REQUIRED FOR FUTURE RADON FAN (CIRCUIT 2F-17) PROVIDE 3/4" C TO ROOF FOR HEAT TRACE CIRCUIT AT INTERNAL DOWNSPOUTS. (2F-25) 2F-15 2F-15 2F-15 2F-15 2F-15 2F-152F-15 2F-15 2F-15 2F-13 2F-13 1F-23 1F-23 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 2F-13 LUNOS e2 ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN OUTL. W/ SWITCH ALIGN OUTL. W/ SWITCH ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN TOP OF OUTLET W/ WINDOW HEAD (TYP OF ALL MD) 2F-15 2F-15 2F-152F-15 2F-13 ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 5.08 SMI PRICE REVIEW SET 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E1.06 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Second Floor Power Plan Drawing: Second Floor Power Plan Scale: 1/4" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: PANEL 2FFOYER 301 Ceiling Ht:8.00 MASTER BED 2 310 Ceiling Ht:8.50 MASTER BATH 311 Ceiling Ht:Varies STAIR 314 Ceiling Ht:8.00 BEDROOM 4 307 Ceiling Ht:8.00 BEDROOM 3 304 Ceiling Ht:8.00 GALLERY 302 Ceiling Ht:8.00 BATH 306 Ceiling Ht:8.00 WIC 312 Ceiling Ht:8.50 LAUNDRY 313 Ceiling Ht:8.00 H2-2 H2-2 CG2-1 BATH 309 Ceiling Ht:8.00 VOID - Ceiling Ht:8.00 2F-9 2F-27,29 2F-72F-5 2F-12F-11 2F-62F-4 2F-2 2F-10 BL-28 (ALL LUNOS UNITS) LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 2F-19 2F-8 2F-3 42" AFF42" AFF96" AFFGFCI (WP/WR)36" AFF 42" AFF 42" AFF 42" AFF 42" AFFGFCI (WP/WR)GFCI (WP/WR) JGFCIGFCILCD GFCI GFCIGFCIGFCIGFCIMD MD MD MD 42" AFF 36" AFF 96" AFFJ PROVIDE POWER TO STEAM SHOWER GENERATOR. SEE MANUFACTURER SPECIFICATIONS. 3#6, 1#16G, 1" C 3#10, 1#10G, 3/4" C PROVIDE WIRING AS REQUIRED FOR FUTURE RADON FAN (CIRCUIT 2F-17) PROVIDE 3/4" C TO ROOF FOR HEAT TRACE CIRCUIT AT INTERNAL DOWNSPOUTS. (2F-25) 2F-14,16 2F-12 60AS LUNOS e2 ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN OUTL. W/ SWITCH ALIGN OUTL. W/ SWITCH ALIGN SWITCH & OUTLET W/ LIGHT ABV ALIGN TOP OF OUTLET W/ WINDOW HEAD (TYP OF ALL MD) ELECTRICAL GENERAL NOTES 1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE. 2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS. 5.08 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E2.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Fire Alarm Plans Drawing: Fire Alarm Plans Scale: 3/16" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DWF CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD CO+SD BOILER BOILER UH 1 FACP 16/4 FPLP FIRE WIRE, TYP UON 16/6 FPLP FIRE WIRE BATH 114 Ceiling Ht:7.67 BATH 107 Ceiling Ht:7.67 LIVING 105 Ceiling Ht:7.67 FOYER 104 Ceiling Ht:7.67 BEDROOM 1 106 Ceiling Ht:7.67 HALL 108 Ceiling Ht:7.67 BEDROOM 2 111 Ceiling Ht:7.67 GARAGE 122 Ceiling Ht: Varies GYM 120 Ceiling Ht:7.67 BATH 112 Ceiling Ht:7.67 (2) O2 Gen STACKED O2 Gen OFFICE 116 Ceiling Ht:8.50 HALL 115 Ceiling Ht:7.67' BOILER MEDIA ROOM 119 Ceiling Ht:8.50 MEDIA ROOM 119 Ceiling Ht:8.92 MUD ROOM 117 Ceiling Ht:8.00 FOYER 101 Ceiling Ht:8.08 MECH RM 113 Ceiling Ht:8.63 MECH RM 102 Ceiling Ht:7.63 ROOF DRAINAGE PEX MANIFOLDS2017 Volvo XC90 6'-7" x 16'-3" 2010 Ford Taurus 6'-4" x 16'-11" Suburban (Outline) 6'-9" x 18'-8.5" Jeep Cherokee 6'-3.5" x 15'-2" LUNOS e2 CO+SD LCD CO+SD DHW DHW FIRE SPRINKLER WATER FLOW FIRE SPRINKLER TAMPER FIRE SPRINKLER TAMPER FIRE ALARM KEYPAD DHW HORN/STROBE DW DWF CO+SD CO+SD CO MASTER BATH 211 Ceiling Ht:8.50 MASTER BED 210 Ceiling Ht:8.50 KITCHEN 203 Ceiling Ht:8.50 FOYER 201 Ceiling Ht:8.50 WC 208 Ceiling Ht:8.50 WIC 212 Ceiling Ht:8.50 MWLUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2WALLOVEN COFFEE F LCD 16/4 FPLP FIRE WIRE, TYP UON 16/6 FPLP FIRE WIRE TO BASEMENT FACP TO BASEMENT FACP CO+SD CO+SD CO+SD CO+SD CO+SD FOYER 301 Ceiling Ht:8.00 MASTER BED 2 310 Ceiling Ht:8.50 MASTER BATH 311 Ceiling Ht:Varies STAIR 314 Ceiling Ht:8.00BEDROOM 4 307 Ceiling Ht:8.00 BEDROOM 3 304 Ceiling Ht:8.00 GALLERY 302 Ceiling Ht:8.00 BATH 306 Ceiling Ht:8.00 WIC 312 Ceiling Ht:8.50LAUNDRY 313 Ceiling Ht:8.00 BATH 309 Ceiling Ht:8.00 VOID - Ceiling Ht:8.00 LUNOS eGO LUNOS e2 LUNOS e2 LUNOS e2 LUNOS e2 CO+SD LCD 16/4 FPLP FIRE WIRE, TYP UON 16/6 FPLP FIRE WIRE LUNOS e2 TO BASEMENT FACP TO BASEMENT FACP SCALE: 3/16" = 1'-0" Fire Alarm Plan - Basement SCALE: 3/16" = 1'-0" Fire Alarm Plan - First Floor SCALE: 3/16" = 1'-0" Fire Alarm Plan - Second Floor INSTALLATION GUIDELINES: Fire alarm installation personnel shall meet the criteria set forth in NFPA 72 and this standard. Installation shall be supervised or completed by technicians holding a NICET II or higher level of certification. Monitored residential fire alarm systems shall zoned by floor. Fully addressable point to point identification is no longer required. (Residential systems only). Combination systems are not approved for installation. Monitored detection is required throughout entire premise. Detection location and spacing shall be per the latest version of NFPA 72, the 2015 IFC and as set forth herein: Shall be installed in a corridor not more than fifteen feet from the door of the farthest bedroom. Smoke detection is required in living rooms, family rooms, home theatres and any rooms that may be used for sleeping. Detectors need to be installed toward the middle of the room but with consideration of proximity to bathrooms, ceiling fans and return air ducts. Kitchens and garages are not required to have heat detection installed. Garages shall be either equipped with a sounding keypad or notification device. Rooms containing (Alarm System) Control Units are not required to be furnished with smoke or heat detecting devices unless otherwise required by this standard or the latest version of NFPA 72. (Applies to residential systems only). Storage rooms and closets are not required to have smoke detection. Unfinished crawl spaces are not required to have smoke detection. Carbon monoxide detection is required to be installed per the latest version of NFPA 72 and Colorado HB 1091. Additionally the following installation requirements shall be met: Shall be installed within a corridor no further than 15 feet from the door of the farthest bedroom. Within twenty feet of fuel fired appliances, including stoves, gas fire places, wood burning stoves or wood burning fire places. Entrance vestibules from attached garages shall be equipped with carbon monoxide detection. Areas not previously considered that are equipped with gas fired appliances that may pose a risk to health and life safety of occupants should there be a build up of carbon monoxide. The installation of combination smoke and carbon monoxide alarms is permitted provided the temporal sounding requirements of NFPA 72 and 720 are met. Carbon monoxide detection shall be monitored when a building or residence is equipped with a monitored fire alarm system. If the existing system is not capable of monitoring carbon monoxide detection then plug in/battery back up detection shall be allowed until such a time that a system is upgraded or replaced. Please contact VF&ES if you have questions. KNOX BOX / CONTACT INFORMATION: All properties equipped with a monitored fire alarm system are required to have an approved key box on the exterior of the property. Location shall be approved by VF&ES. Key boxes shall be furnished by the Knox Company. Boxes may be ordered electronically. Contact VF&ES Prevention Office for further guidance if needed. Step by step ordering instructions are provided on the Prevention Bureau page. Duplex and multi-family occupancies are permitted to share a single key box. Key boxes are not required to be equipped with monitored tamper switches. Master keys and key cards are required to be presented for installation in the key box at final inspection. Keys will not be accepted by VF&ES personnel except when on property and in the presence of a contractor or responsible party. Keys will be clearly marked as to what doors they will operate. FA PLAN GENERAL NOTES: 1. WIRE LOCATIONS SHOWN ARE SCHEMATIC ONLY. RUN FIRE ALARM SYSTEM WIRING ADJACENT TO SPRINKLER LINES SO THAT THE WIRE IS AVAILABLE FOR ONSITE INSPECTION AFTER MODULE PLACEMENT. 2. NO SUBSTITUTIONS OF FA EQUIPMENT WILL BE ACCEPTED. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E6.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Electrical Schedule Drawing: Electrical Schedule Scale: CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: Electrical: Combined LC and MC Scopes Home Story BSMT/Garden Level First Floor 2D Symbol CO+SD LCDA1R A3R E1 F4 G1 G2 G3 G6 G7 G8 J1 M2 xx J JGFCIGFCI (WP/WR)GFCI (WP/WR)RM 6C P P2 P3R H6 T TTDa CO CO+SD LCDA1R A3R D E1 E2 F1 F2 F3 G3 J1 M1 M2 J JMD 90" AFF24" AFF 36" AFFID COAXIAL JACK Combination Smoke, CO Detector DATA JACK DISCONNECT FACP Fire alarm Keypad Fixture A1 Recessed Downlighting Fixture A3 Recessed Downlighting Fixture E1 Exterior Wall Sconce Fixture F4 TBD Fixture G1 Fluorescent w/ 13W lamp Fixture G2 Fluorescent strip light Fixture G3 Linear T8 fluorescent Light 2' Fixture G5 Under Cabinet Lighting Fixture G6 Surface mount ceiling 11" Fixture G7 Surface mount ceiling 6" Fixture G8 TBD Fixture J1 Vanity sconce Fixture M2 LEDme Step Light, interior Fixture XX Interior Wall Sconce HORN/STROBE JUNCTION BOX JUNCTION BOX OUTLET-DUPLEX - FLOOR OUTLET-DUPLEX TR OUTLET-GFCI OUTLET-GFCI EXT OUTLET-GFCI EXT OUTLET-Special Panel BA Panel BL RadioRA Main Repeater SWITCH-BIPOLE SWITCH-BIPOLE SWITCH-DIMMER-6C SWITCH-HVAC SWITCH-PICO-2B SWITCH-PICO-2BRL SWITCH-PICO-3BRL SWITCH-Rotary Switch for Lunos SWITCH-WALL STATION-6 BUTTON Switch-Bipole-Timer TIMER Thermostat CO Detector COAXIAL JACK Combination Smoke, CO Detector DATA JACK DATA JACK DISCONNECT Fire alarm Keypad Fixture A1 Recessed Downlighting Fixture A3 Recessed Downlighting Fixture D Bollard Fixture E1 Exterior Wall Sconce Fixture E2 Exterior Wall Sconce Fixture F1 TBD Fixture F2 TBD Fixture F3 TBD Fixture G3 Linear Closet Light 2' Fixture G5 Under Cabinet Lighting Fixture J1 Vanity sconce Fixture M1 LEDme Step Light, exterior Fixture M2 LEDme Step Light, interior JUNCTION BOX JUNCTION BOX OUTLET - FOR MOTORIZED DRAPERY OUTLET-220V OUTLET-DUPLEX OUTLET-DUPLEX - FLOOR QNTY 6 9 10 2 1 1 40 3 6 1 3 4 3 1 8 2 2 6 6 6 1 3 10 4 102 7 3 2 1 1 1 1 28 5 17 1 1 1 3 4 1 3 1 7 1 2 2 6 2 1 1 73 1 4 6 4 2 1 1 2 4 5 7 6 3 2 3 2 1 2 Serial Number COSMO-2W 40649-W - Cat 6 B4512 B942 3" H36ICAT-Housing with 3003WHWB White baffle trim 3" H36ICAT-Housing with 3008FG White shower trim WS-W2605-BK 078477360606 AWN8-232-EU MP5-117-OCT-A-WHT-ELB-UNI AL-SL-NN-U-WW-24 with AL-TRK- NS-F1 aluminum mounting channel 700CQLC-LED3 700CQSC-LED3 ***TBD*** BV471-10-15 WL-LED300-C-WT ***TBD*** P2RK 25249-SBA 1278-W30 RR-MAIN-REP RRD-8ANS-WH PER CONTRACTOR RRD-6CL-WH PJ2-2B-GWH-L01 (CW-1-WH) PJ2-2BRL-GWH-L01(CW-1-WH) PJ2-3BRL-GWH-L01(CW-1-WH) Rotary Switch for Lunos RRD-H6-BRL MA-T51-WH Nest Thermostat E CO 1224 COSMOD4W or 2W 40649-W - Cat 6 40649-W - Cat 6 B942 H36ICAT-Housing, 3003WHWB White Baffle 3" H36ICAT-Housing with 3008FG White shower trim 700OBSTR-830-42-CZ-UNV2 WS-W2605-BK WO856-BK MP5-117-OCT-A-WHT-ELB-UNI AL-SL-NN-U-WW-24 with AL-TRK- NS-F1 aluminum mounting channel BV741-10-15 WL-LED100-C-SS WL-LED300-C-WT 25249-SBA Manufacturer & Series System Sensor Leviton, Decora screwless BOSCH BOSCH Halo Halo WAC Lighting, Tube ***TBD*** Leviton Columbia Lighting Mercury Lighting aspectLED, N-Series TECH Lighting TECH Lighting ***TBD*** Alico Industries, Borg WAC Lighting, LEDme ***TBD*** Bosch Leviton Leviton Leviton Leviton Leviton Leviton LUTRON RadioRA 2 LUTRON RadioRA 2 PER CONTRACTOR LUTRON RadioRA 2 LUTRON LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 foursevenfive.com LUTRON RadioRA 2 LUTRON RadioRA 2 Nest System Sensor System Sensor Leviton, Decora screwless Leviton, Decora screwless BOSCH Halo Halo TECH Lighting, Strut WAC Lighting, Tube Stone Lighting ***TBD*** ***TBD*** ***TBD*** Mercury Lighting aspectLED, N-Series Alico Industries, Borg WAC Lighting, LEDme WAC Lighting, LEDme Leviton Leviton Leviton Leviton Note/Remarks Height as indicated on plan (16" aff if blank) White, Height as indicated on plan (16" aff if blank) Fire Alarm Control Panel - Provide 24"x24" Acerbox housing with 21" x 20" backplate (per CSWC Specifications) WHITE LC supplies and installs LED bulbs! In ±8' ceilings - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam) LC supplies & installs LED bulbs! - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam) Wall sconce Integral LED, Black Fluorescent, Wall switch operated 8' T8 fluorescent strip light Linear T8 Fluorescent LED Tape full width of wall cabinets. Requires power supply. 24VDC LED 3000K 120V LED 3000K 120V Office and Hall fixtures Bath Vanity Light, Chrome Finish, mount on mirror LED, round, white Media Room Sconces Outdoor Horn/Strobe Equipment or Appliance For self-regulating heat cable Brushed Nickel Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled Weather Resistant installed in water proof box. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled Weather Resistant installed in water proof box. Height as indicated on plan (16" aff if blank) Decora, screwless, white, 220. Dryer receptacle 400 A 30' range RadioRA 2 Maestro, screwless, white, FOR MECH EQUIPMENT RadioRA 2 Maestro, screwless, white, screwless, white, (NEED NOT BE COMPATIBLE WITH RADIORA) PICO 2 BUTTON WITH RAISE/LOWER PICO 3 BUTTON WITH RAISE/LOWER Chrome dial, white background SIX BUTTON WALL STATION Maestro, screwless, white For self-regulating heat cable Meets NFPA 720:2009 Height as indicated on plan (16" aff if blank) UL 864 and 985 Listed for use with fire protection signaling systems White, Height as indicated on plan (16" aff if blank) White, Height as indicated on plan (16" aff if blank) WHITE LC supplies & installs LED bulbs! 8' ceilings - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam), vaulted SM16GA-07-25D-830-03 (9 watts, 3000K, 25 degree beam)LC supplies and installs LED bulbs! 8' ceilings - SM16-09-36D-830-03 (9 watts, 3000K, 36 degree beam) LED bollard includes stainless steel mounting hardware. Options as required. Wall sconce Integral LED, Black Wall sconce, 3x1w Cree LED, 120 V, 3000 K Linear T8 Fluorescent LED Tape full width of wall cabinets. Requires power supply. 24VDC Bath Vanity Light, Chrome Finish LED, square, stainless steel LED, round, white Equipment or Appliance For self-regulating heat cable Decora, screwless, white, UL Listed and labeled ALIGN TOP W/ WINDOW HEAD (TYP OF ALL) Decora, screwless, white, Tamper Resistant, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Brushed Nickel Supplied By: LC LC LC LC LC LC LC LC Client LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC MC MC MC MC LC LC MC MC LC LC LC Client Client Client MC MC LC LC LC LC LC MC MC MC MC Installed by: LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC MC MC MC MC LC LC MC MC LC LC LC LC LC LC MC MC LC LC LC LC LC MC MC MC LC Electrical: Combined LC and MC Scopes Home Story Second Floor Roof 2D Symbol 42" AFFGFCI GFCI (WP/WR)42" AFFRA 6C DAR H5 H6T QT T1T2 T3 CO+SD LCDA1R A2R A3R B E1 F2 G3 J1 J JMD 42" AFF42" AFF GFCIGFCI (WP/WR) RM 6CP3 RH5H6 T4 T5 T6 T7J ID OUTLET-DUPLEX TR OUTLET-DUPLEX TR OUTLET-GFCI OUTLET-GFCI EXT OUTLET-QUAD TR PANEL 1F RadioRA Auxiliary Repeater SWITCH-BIPOLE SWITCH-DIMMER-6C SWITCH-Door Activated SWITCH-Rotary Switch for Lunos SWITCH-WALL STATION-5 BUTTON SWITCH-WALL STATION-6 BUTTON Switch-Bipole-Timer TABLETOP STATION Thermostat Z1 Thermostat Z2 Thermostat Z3 COAXIAL JACK Combination Smoke, CO Detector DATA JACK DATA JACK DISCONNECT Fire alarm Keypad Fixture A1 Recessed Downlighting Fixture A2 Recessed Directional Fixture A3 Recessed Downlighting Fixture B Surface Mounted LED Downlight Fixture E1 Exterior Wall Sconce Fixture F2 TBD Fixture G3 Linear Closet Light 2' Fixture G5 Under Cabinet Lighting Fixture J1 Vanity sconce JUNCTION BOX JUNCTION BOX OUTLET - FOR MOTORIZED DRAPERY OUTLET-DUPLEX OUTLET-DUPLEX OUTLET-DUPLEX TR OUTLET-DUPLEX TR OUTLET-DUPLEX-SWITCHED OUTLET-GFCI OUTLET-GFCI EXT OUTLET-Special PANEL 2F RadioRA Main Repeater SWITCH-BIPOLE SWITCH-Bipole SWITCH-DIMMER-6C SWITCH-PICO-3BRL SWITCH-Rotary Switch for Lunos SWITCH-WALL STATION-5 BUTTON SWITCH-WALL STATION-6 BUTTON Thermostat Z4 Thermostat Z5 Thermostat Z6 Thermostat Z7 JUNCTION BOX QNTY 42 1 16 11 2 1 2 2 39 2 3 2 5 1 2 1 1 1 3 6 3 2 1 1 47 6 3 3 1 3 2 1 9 1 1 4 3 45 3 1 3 7 3 1 1 1 3 1 24 5 5 2 1 1 1 1 1 1 817 Serial Number RR-AUX-REP RRD-8ANS-WH RRD-6CL-WH CA-1PS-WH Rotary Switch for Lunos RRD-H5-BRL RRD-H6-BRL MA-T51-WH RR-T15RL-WH Nest Thermostat E Nest Thermostat E Nest Thermostat E COSMOD4W or 2W 40649-W - Cat 6 40649-W - Cat 6 B942 H36ICAT-Housing, 3003WHWB White baffle trim H38ICAT-Housing, 3009WHWB White with white baffle gimbal 3" H36ICAT-Housing with 3008FG White shower trim 700CQSC-LED3 WS-W2605-BK MP5-117-OCT-A-WHT-ELB-UNI AL-SL-NN-U-WW-24 with AL-TRK- NS-F1 aluminum mounting channel BV741-10-15 GFNT1-PW Leviton GFWR1-W 1278-W30 RR-MAIN-REP RRD-8ANS-WH RRD-6CL-WH RRD-6CL-WH PJ2-3BRL-GWH-L01(CW-1-WH) Rotary Switch for Lunos RRD-H5-BRL RRD-H6-BRL Nest Thermostat E Nest Thermostat E Nest Thermostat E Nest Thermostat E Manufacturer & Series Leviton Leviton Leviton Leviton Leviton LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 Leviton foursevenfive.com LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 Nest Nest Nest System Sensor Leviton Levito BOSCH Halo Halo Halo TECH Lighting, Cirque WAC Lighting, Tube ***TBD*** Mercury Lighting aspectLED, N-Series Alico Industries, Borg Leviton Leviton Leviton Leviton Leviton Leviton Leviton Leviton Leviton LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 LUTRON RadioRA 2 foursevenfive.com LUTRON RadioRA 2 LUTRON RadioRA 2 Nest Nest Nest Nest Note/Remarks Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled Weather Resistant installed in water proof box. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) 30' range RadioRA 2 Maestro, screwless, white, RadioRA 2 Maestro, screwless, white, Chrome dial, white background FIVE BUTTON WALL STATION SIX BUTTON WALL STATION Maestro, screwless, white 15 BUTTON TABLETOP STATION Height as indicated on plan (16" aff if blank) UL 864 and 985 Listed for use with fire protection signaling systems Decora, screwless, White. Height as indicated on plan (16" aff if blank) Decora, screwless, White. Height as indicated on plan (16" aff if blank) WHITE LC supplies & installs LED bulbs! 8' ceilings - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam), vaulted SM16GA-07-25D-830-03 (9 watts, 3000K, 25 degree beam)LC supplies and installs LED bulbs! In ±8' ceilings - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam). H38ICAT housing required due to reduced spacing at double structural membersLC supplies and installs LED bulbs! In ±8' ceilings - SM16GA-07-36D-830-03 (9 watts, 3000K, 36 degree beam) LED, Chrome Wall sconce Integral LED, Black Linear T8 Fluorescent LED Tape full width of wall cabinets. Requires power supply. 24VDC Bath Vanity Light, Chrome Finish Equipment or Appliance For self-regulating heat cable Decora, screwless, white, UL Listed and labeled, Tamper Resistant. ALIGN TOP W/ WINDOW HEAD Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) Decora, screwless, white, Tamper Resistant, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled, Tamper Resistant. Height as indicated on plan (16" aff if blank) Decora, screwless, white, Tamper Resistant,UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled. Height as indicated on plan (16" aff if blank) Decora, screwless, white, UL Listed and labeled Weather Resistant installed in water proof box. Height as indicated on plan (16" aff if blank) Decora, screwless, white, 220. Dryer receptacle 30' range RadioRA 2 Maestro, screwless, white, RadioRA 2 Maestro, screwless, white, RadioRA 2 Maestro, screwless, white, PICO 3 BUTTON WITH RAISE/LOWER Chrome dial, white background FIVE BUTTON WALL STATION SIX BUTTON WALL STATION For self-regulating heat cable Supplied By: MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC LC LC LC MC MC MC LC LC MC MC MC LC LC CLIENT MC MC LC LC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC LC LC LC LC LC Installed by: MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC LC LC LC MC MC MC LC LC MC LC MC LC LC LC MC MC LC LC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC MC LC LC LC LC LC ELECTRICAL GENERAL NOTES1. ALL FACE PLATES TO BE INSTALLED IN FIELD. VERIFY SHIP LOOSE QUANTITY AND STYLE.2. SEE SPECIFICATIONS AND ELECTRICAL SCHEDULES FOR SELECTIONS. NOTIFYARCHITECT OF ANY DISCREPANCIES.3. SEE REFLECTED CEILING PLAN FOR ALL FIXTURE LOCATIONS.5.08 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 08 Electrical Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: E6.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Electrical Panel Schedule & Riser Diagram Drawing: Electrical Panel Schedule & Riser Diagram Scale: 1:65.52 CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 1 1 1 1 PANEL 1F LOAD CALCULATION (NEC 220.82) GENERAL LOAD DEMAND CALCULATION GENERAL LIGHTING AND RECEPTACLES FIRST FLOOR SMALL APPLIANCE BRANCH CIRCUITS REFRIGERATOR / FREEZER DINING ROOM / PANTRY DISHWASHER / DISPOSAL WINE COOLER MICROWAVE COFFEE HOOD COUNTERTOP AND ISLAND HARDWIRED APPLIANCES / EQUIPMENT STEAM OVEN WARMING DRAW INDUCTION COOKTOP STEAM SHOWER GENERATOR GENERAL LOAD DEMAND GENERAL LOAD TOTAL 1ST 1kVA AT 100% REMAINDER AT 40% GENERAL LOAD DEMAND FEEDER CALCULATION PANEL 1F DEMAND (kVA) = GENERAL LOAD + HVAC PANEL 1F DEMAND (A) AT 240V - 1 PHASE SQFT 2305 QTY 2 2 2 1 1 1 1 3 QTY 1 1 1 1 VA/SQFT 3 LOAD (kVA) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 LOAD (Kva) 3.7 0.45 3.7 9 LOAD (kVA) 6.9 TOTAL LOAD (Kva) 3 3 3 1.5 1.5 1.5 1.5 4.5 TOTAL LOAD (Kva) 3.7 0.45 3.7 9 43.4 10.0 13.4 23.4 23.4 97.4 PANEL 2F LOAD CALCULATION (NEC 220.82) GENERAL LOAD DEMAND CALCULATION GENERAL LIGHTING AND RECEPTACLES SECOND FLOOR LAUNDRY CIRCUIT LAUNDRY HARDWIRED APPLIANCES / EQUIPMENT DRYER STEAM SHOWER GENERATOR GENERAL LOAD DEMAND GENERAL LOAD TOTAL 1ST 1kVA AT 100% REMAINDER AT 40% GENERAL LOAD DEMAND FEEDER CALCULATION PANEL 2F DEMAND (kVA) = GENERAL LOAD + HVAC PANEL 2F DEMAND (A) AT 240V - 1 PHASE SQFT 2375 QTY 1 1 1 VA/SQFT 3 LOAD (kVA) 1.5 5 9 LOAD (kVA) 7.1 TOTAL LOAD (Kva) 1.5 5 9 22.6 10.0 5.1 15.1 15.1 62.7 PANEL BA LOAD CALCULATION (NEC 220.82) GENERAL LOAD DEMAND CALCULATION GENERAL LIGHTING AND RECEPTACLES BASEMENT SMALL APPLIANCE / LAUNDRY BRANCH CIRCUITS SMALL APPLIANCE LAUNDRY HARDWIRED APPLIANCES / EQUIPMENT WALL OVEN ELECTRIC COOKTOP DRYER GENERAL LOAD DEMAND GENERAL LOAD TOTAL 1ST 1kVA AT 100% REMAINDER AT 40% GENERAL LOAD DEMAND HVAC LOAD DEMAND (1) GAS WATER HEATER POWER VENTED TOTAL HVAC DEMAND FEEDER CALCULATION SERVICE DEMAND (kVA) = GENERAL LOAD + HVAC SERVICE DEMAND (A) AT 240V - 1 PHASE SQFT 1036 QTY 4 2 QTY 1 1 1 VA/SQFT 3 LOAD (kVA) 1.5 1.5 LOAD (Kva) 3.1 3 5 LOAD (kVA) 3.1 TOTAL LOAD (Kva) 6 3 TOTAL LOAD (Kva) 3.7 3 5 23.8 10.0 5.5 15.5 LOAD (kVA) 0.2 0.2 15.7 65.5 PANEL BL CALCULATION (NEC 220.82) GENERAL LOAD DEMAND CALCULATION GENERAL LIGHTING AND RECEPTACLES BASEMENT HARDWIRED APPLIANCES / EQUIPMENT GAS WATER HEATER SAUNA HEATER ELVATOR GENERAL LOAD DEMAND GENERAL LOAD TOTAL 1ST 1kVA AT 100% REMAINDER AT 40% GENERAL LOAD DEMAND HVAC LOAD DEMAND (3) GAS BOILERS UH-1 (HOT WATER) (3) PUMPS - SNOW MELT/HOT WATER CIRCULATOR HEAT TRACE TOTAL HVAC DEMAND FEEDER CALCULATION SERVICE DEMAND (kVA) = GENERAL LOAD + HVAC SERVICE DEMAND (A) AT 240V - 1 PHASE SQFT 2650 QTY 2 1 1 VA/SQFT 3 LOAD (Kva) 0.6 10 9.6 LOAD (kVA) 8.0 TOTAL LOAD (Kva) 1.2 10 9.6 28.8 10.0 7.5 17.5 LOAD (kVA) 0.5 0.1 0.7 1.5 2.9 20.4 84.9 SERVICE CALCULATION (NEC 220.82) GENERAL LOAD DEMAND CALCULATION GENERAL LIGHTING AND RECEPTACLES BASEMENT FIRST FLOOR SECOND FLOOR SMALL APPLIANCE / LAUNDRY BRANCH CIRCUITS REFRIGERATOR / FREEZER / HOOD MICROWAVE DINING ROOM / PANTRY DISHWASHER / DISPOSAL COUNTERTOP RECEPTACLES WINE COOLER COFFEE LAUNDRY HARDWIRED APPLIANCES / EQUIPMENT STEAM OVEN WALL OVEN WARMING DRAW INDUCTION COOKTOP ELECTRIC COOKTOP DRYER GAS WATER HEATER STEAM SHOWER GENERATOR SAUNA HEATER ELVATOR GENERAL LOAD DEMAND GENERAL LOAD TOTAL 1ST 10kVA AT 100% REMAINDER AT 40% GENERAL LOAD DEMAND HVAC LOAD DEMAND (1) GAS WATER HEATER POWER VENTED (3) GAS BOILERS UH-1 (hot water) (3) PUMPS - SNOW MELT/HOT WATER CIRCULATOR HEAT TRACE TOTAL HVAC DEMAND SERVICE CALCULATION SERVICE DEMAND (kVA) = GENERAL LOAD + HVAC SERVICE DEMAND (A) AT 240V - 1 PHASE SQFT 3686 2305 2375 QTY 4 2 2 3 4 1 1 2 QTY 1 1 1 1 1 2 2 2 1 1 VA/SQFT 3 3 3 LOAD (kVA) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 LOAD (Kva) 4.8 3.1 0.45 3.7 3 5 0.6 9 10 9.6 LOAD (kVA) 11.1 6.9 7.1 TOTAL LOAD (Kva) 6 3 3 4.5 6 1.5 1.5 3 TOTAL LOAD (Kva) 3.7 3.7 0.45 3.7 3 10 1.2 18 10 9.6 116.9 10.0 42.8 52.8 LOAD (kVA) 0.2 0.5 0.1 0.7 1.7 3.2 56.0 233.3 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "A" ARC FAULT CB DESCRIPTION MASTER BED 209 MASTER BED 209 WALK IN CLOSET 210 MASTER BATH 211 MASTER BATH 211 FOYER 201 MASTER BATHROOM LIGHTING FOYER-MASTER BED LIGHTING WARMING DRAW SPARE SPARE INSIDE STAIRWELL LIGHTING RECEPT-FRONT DOOR EXTERIOR RECEPTACLES SPARE SPARE SPARE SPARE STEAM SHOWER GENERATOR VOLTAGE: AMPS: PANEL: 240/120V, 1Ø, 3W 100 1F LTG REC HVAC MISC. C/B 20/1"A" 20/1"A" 20/1"A" 20/1 20/1 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1 20/1"A" 20/1"A" 20/1"A" 20/1"A" 50/2 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC A B A B A B A B A B A B A B A B A B A B X X C/B 20/1 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/2 20/2 20/1"A" 20/1"A" 20/1"A" MISC. HVAC REC ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C/B's LTG DESCRIPTION EXTERIOR RECEPTACLES LIVING ROOM LIVING ROOM KITCHEN COUNTERTOP KITCHEN COUNTERTOP KITCHEN COUNTERTOP / ISLAND DISHWASHER / DISPOSAL DISHWASHER REFRIGERATOR REFRIGERATOR HOOD PANTRY DINING INDUCTION COOKTOP STEAM OVEN DINING MICROWAVE COFFEE CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 DESCRIPTION MASTER SUITE 310 MASTER SUITE 310 WALK IN CLOSET 312 MASTER BATH 311 MASTER BATH 311 FOYER 301 / LAUNDRY RM INTERIOR LIGHTING INTERIOR LIGHTING EXHAUST FAN - RADON RECEPT-1ST FL HIGH CEILING SPARE SPARE SPARE STEAM SHOWER GENERATOR VOLTAGE: AMPS: PANEL: 240/120V, 1Ø, 3W 100 2F LTG REC HVAC MISC. C/B 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1"A" 50/2 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC A B A B A B A B A B A B A B A X X C/B 20/1"A" 20/1"A" 20/1"A" 20/1"A" 20/1 20/1"A" 30/2 20/1"A" 20/1"A" 20/1"A" MISC. HVAC REC ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C/B's LTG DESCRIPTION GALLERY/BALCONY BEDROOM 304 BEDROOM 307 WALK IN CLOSETS BATH 306 / 309 LAUNDRY DRYER SPARE SPARE SPARE SPACE SPACE SPACE SPACE CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "A" ARC FAULT CB DESCRIPTION OFFICE 116 OFFICE 116 HALL / MUD ROOM MEDIA ROOM MEDIA ROOM MEDIA ROOM MEDIA ROOM GYM 120 GYM 120 GYM 120 OXYGEN GENERATORS LIGHTING LTG-EXTERIOR & GARAGE HEAT TRACE HEAT TRACE WATER HEATER SPARE SAUNA PANEL BA VOLTAGE: AMPS: PANEL: 240/120V, 1Ø, 3W 250 BL LTG REC HVAC MISC. C/B 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1 20/1 20/1 20/1 20/1'A' 60/2 100/2 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC A B A B A B A B A B A B A B A B A B A B A X X C/B 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1'A' 20/1 20/1'A' 20/1'A' 20/1'A' 50/2 100/2 100/2 MISC. HVAC REC ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C/B's LTG DESCRIPTION PUMPS BOILERS GARAGE UH-1 BOILER ROOM MECHANICAL 102 GARAGE OPENERS GARAGE OPENERS GARAGE OPENERS EXTERIOR RECEPTACLES BATH 114 FACP FOYER 101 LUNOS UNITS SPARE ELEVATOR PANEL 1F PANEL 2F CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "A" ARC FAULT CB DESCRIPTION LIIVING 105 LIVING 105 MECHANICAL 113 / HALL 108 MECHANICAL 113 BEDROOM 111 BEDROOM 106 BATH 107 - 112 EXTERIOR RECEPT LIGHTING SPARE SPARE SPARE GAS WATER HEATER SPARE SPARE VOLTAGE: AMPS: PANEL: 240/120V, 1Ø, 3W 100 BA LTG REC HVAC MISC. C/B 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1 20/1 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1 20/1'A' 20/1'A' MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC A B A B A B A B A B A B A B A X X C/B 20/1'A' 20/1'A' 20/1'A' 20/2 20/2 30/2 20/1'A' 20/1'A' 20/1'A' 20/1'A' 20/1 MISC. HVAC REC ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C/B's LTG DESCRIPTION FRIDGE / HOOD COUNTERTOP RECEPT DISHWASHER / DISPOSAL ELECTRIC COOKTOP WALL OVEN DRYER LAUNDRY MICROWAVE SPARE SPACE SPACE SPARE CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 ELECTRIC UTILITY SERVICE TRANSFORMER (BY LOCAL ELECTRICAL COMPANY) PANEL "BA" 240/120V-1ɸ-3W 100 AMP MLO FIRST FLOOR BASEMENT SECOND FLOOR PANEL "1F" 240/120V-1ɸ-3W 100 AMP MLO PANEL "2F" 240/120V-1ɸ-3W 100 AMP MLO 3#250 KCMIL, #1/0(G), 3" PVC CONDUIT 1 SPARE 3" PVC CONDUIT WITH PULLSTRING 1 1 1 1 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR AVAILABLE FAULT CURRENT. PROVIDE PANEL WITH 'KAIC' RATING HIGHER THAN AVAILABLE FAULT CURRENT. XXCODED NOTES: 1 PANEL "BL" 240/120V-1ɸ-3W 250A MCB U.L. SERVICE ENTRANCE RATED 3#1, #8(G), 11/2"C 100A/2P 100A/2P 100A/2P 5.08 10/11/18 Landscape Plan 15.0 3. 0 15 .0 20.0'SETBAC K LINESETBACK LINE4:1 SLOPE8592 859 0 8592 8588 8586 FF=90.5 85928594 8596 8589.21 18" STORM DRAI N PI PE D RAIN TO D AYLIGHT8590 8 5 9 2 859685 9 0 PARKING AREA 8 5 9 0 8590 8588 8588 8588 HOT TUB DECK HEATED DRIVEWAY LIMITS OF DISTU R B A N C E LIMITS OF DISTURBANCEM A I N G O R E D R I V E S O U T H DOG DOG DOG DOG DOG DOG DOG DOG N N N N N N N N N N N N N N N N sb sb sb sb sb sb sb sb SIDEWALK SOD NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS SOD SOD SOD SOD SOD NATIVE GRASS sb sb sb sb sb sg sg sg sg sg sg sg sg sb sb sb sb SNOW STORAGE sb sb sb sb sb sb Tel Ped TOW=96 BOX=90 TOW=95 BOW=89.3 8589.408589.40 8589.40 8589.34 DRAIN TO DAYLIGHT 94.0 93.6 TOP=88.8 TOP=88.9 STAMPED, ENGINEERED DRAWING FOR RETAINING WALL OVER 4' SEE C-GRADING 15.0 3. 0 15. 0 20.0'SETBAC K LINESETBAC K LINE4:1 SLOPE8592 8590 8592 8588 8586 FF=90.0 85928594 8596 8589.21 STORM DRAIN PIPE DRAI N TO DAYLIGHT 8590 8 5 9 2 8596 85 9 0 PARKING AREA 8 5 9 0 8590 8588 8588 8588 HOT TUB DECK HEATED DRIVEWAY LI MI TS OF DI S T U R B A N C E LIMITS OF DISTURBANCEM A I N G O R E D R I V E S O U T H DOG DOG DOG DOG DOG DOG DOG DOG N N N N N N N N N N N N N N N N sb sb sb sb sb sb sb sb SIDEW ALKSOD NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS NATIVE GRASS SOD SOD SOD SOD SOD NATIVE GRASS sb sb sb sb sb sg sg sg sg sg sg sg sg sb sb sb sb SNOW STORAGE sb sb sb sb sb sb Tel Ped TOW=96 BOX=90 TOW=95 BOW=89.3 8589.258589.40 8589.25 8589.34 DRAIN TO DAYLIGHT 94.0 93.6 TOP=88.8 TOP=88.9 STAMPED, ENGINEERED DRAWING FOR RETAINING WALL OVER 4' SEE C-GRADING AUGUST, 2017 10/11/18 10/11/18 10/11/18 10/11/18 10/11/18 10/11/18 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: M6.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: HVAC Schedules Drawing: HVAC Schedules Scale: 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: EQUIPMENT: MECHANICAL Room # 102 102 103 113 122 122 123 Location MECH RM MECH RM STORAGE MECH RM GARAGE GARAGE STORAGE 2D Symbol Description Gas Fireplace and Flue DHW ELEVATOR PUMP CONTROLLER O2 Gen DHW UH 1 Wine Cooling system BOILER QTY 1 2 1 3 1 1 1 3 Manufacturer Heat N Glo Lochinvar Wet Style Oxygen Company Lochinvar Airtherm (Or Equal) WhisperKool Lochinvar Serial Number Mezzo48 LTN075 75 PPRN040-40ES HA36 KBN-286 Cooling Capacity 5521 BTU/h Heating Capacity 40,000 75.1 MBH 40 MBH 36 MBH / 500 CFM 286 MBH Power Requirements 115V/ 1.2 FLA 115V/20A HSPF COP (47) COP(17) AFUE 48.3 Supply LC LC LC LC LC Install LC LC LC LC LC Notes Direct Vent Nat Gas GAS FIRED DHW TANK, 1/2" gas connection, .6 EF GAS FIRED DHW TANK, 1/2" Gas Connection, .68 EF Unit Heater. 55 deg setpoint Mounted in Garage Ceiling, ducted to wine Cooler 95% efficient Note/Remarks 75 gal Power Vented 40 gal direct power vent Hot water fed from boilers Phantom 5000 Ducted unit Units shown are basis of design. Units shall provide heat for snow melt & hydronic heat as indicated on plans. EQUIPMENT: VENTILATION Floor Level BSMT/Garden Level First Floor Second Floor 2D Symbol Description LUNOS EGO Bath Fan LUNOS E2 Room to Room Fan LUNOS EGO Bath Fan LUNOS E2 LUNOS EGO Bath Fan LUNOS E2 Ventilation Fan Quantity 1 2 6 2 1 1 5 1 2 7 2 Manufacturer --- Aero Pure Lunos Tjernlund Products --- Aero Pure Lunos --- Aero Pure Lunos Panasonic Serial Number --- SBF 110 G5 S e2 AS1 --- SBF 110 G5 S e2 --- SBF 110 G5 S e2 FV-1115VQ1 Ventilation Capacity 12 CFM / 27 CFM (EXHAUST ONLY) 110 CFM 20 CFM 110 CFM 12 CFM / 27 CFM (EXHAUST ONLY) 110 CFM 20 CFM 12 CFM / 27 CFM (EXHAUST ONLY) 110 CFM 20 CFM 150CFM Recovery Efficiency 85% 85% 85% 85% 85% 85% Power Requirements 120 V 120 V 120 V 120 V 120 V 120 V 120 V 120 V 120 V 120 V 120V Supply LC LC LC LC MC MC MC MC MC MC MC Install LC LC LC LC LC MC LC LC MC LC MC Notes LC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES FOR CONTROLS Hard Pipe to Exterior LC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES PER PAIR FOR CONTROLS Hard Pipe to Exterior MC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES FOR CONTROLS Hard Pipe to Exterior MC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES PER PAIR FOR CONTROLS MC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES FOR CONTROLS Hard Pipe to Exterior MC SHALL PROVIDE 12 V WIRE AND (2) 12V SWITCHES PER PAIR FOR CONTROLS Hard Pipe to Exterior HVAC NOTES: 1. VERIFY HIGH ALTITUDE REQUIREMENTS FOR ALL EQUIPMENT. FOR MITSUBISHI UNITS, SEE LATEST APPLICATION NOTE "HIGH ALTITUDE APPLICATIONS" 2. VERIFY SUPPLEMENTAL OXYGEN REQUIREMENTS WITH OWNER, INCLUDING SYSTEM SPECIFICATIONS AND SCOPE. 3. PROVIDE SPACE AND INSTALLATION PREPARATIONS FOR FUTURE HUMIDIFICATION SYSTEM IN BASEMENT MECHANICAL ROOM. 4. PROVIDE MAKEUP AIR FOR RANGE HOODS PER IRC 1503.4. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES W ork in P rogressRevID ChID Change Name Date 01 - WIP 07 Plumbing System Changes Work in Progress evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Basement Drain/ Waste Plan Drawing: Basement Drain/ Waste Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DWF BOT: -2'-21/8" BOILER BOILER UH 1 4" S 4" S 4" S 4" S 1 1/2" S 2" S 2" S 4" S 1 1/2" S 4" S 4" S 1 1/2" S2" S 2" S 4" CAST IRON STACK TO CONNECT TO PVC STACK ABOVE 4" CAST IRON STACK TO CONNECT TO PVC STACK ABOVE 4" PVC RADON VENT SUGGESTED PEX MANIFOLD LOCATIONS 4" S PROVIDE FIRE RATED PIPE COLLARS AT FLOOR PENETRATION FOR RADON VENT AND PLUMBING STACK. (THIS STACK ONLY) SEE FIRE RATED ASSEMBLIES SHEET. FIRE CAULK OR USE APPROPRIATE COLLARS FOR PENETRATIONS IN RATED ASSEMBLIES (CEILING OVER APARTMENT IS REQUIRED TO BE 30 MIN RATED) SEE CIVIL DRAWINGS FOR FOUNDATION DRAIN SPECIFICS, INCLUDING INVERT ELEVATIONS. CIVIL SHALL GOVERN IF CONFLICTS. Invert: -1' Invert: -1'-55/8" Invert: -0'-8" Invert: -1'-51/2" Invert: -2'-1" Invert: -2'-1" Invert: -1'-7" Invert: -3' Invert: -2'-7" Invert: -2'-85/8" Invert: -2'-1" Invert: -3'-95/8" Invert: -2'-67/8" Invert: -1'-85/8" Invert: -4'-13/8" Invert: -4'-1" Invert: -1'-10" INVERT: -2'-6" Invert: -5'-41/4" Invert: -3'-65/8" (2) O2 Gen STACKED O2 Gen CONNECT GAS LINE TO HOT TUB, VERIFY WITH MANUFACTURER SPECIFICATIONS 4" S INVERT: -2'-67/8" Invert: -2'-27/8" CONNECT GAS LINE UP TO FIRE FEATURE Invert: -5'-11" Invert: -5'-113/4" BOILER Invert: TRANSFER FAIN BY TJERNLUND OR EQUAL. INSTALLED WITH INTAKE LOW IN HALLWAY, OUTPUT HIGH IN MEDIA ROOM. (WALL SWITCH) 10" X 10" JUMPER DUCT FOR PRESSURE RELIEF. CONNECT WITH 6" FLEX DUCT. LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE HEATED DRIVEWAY DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT HEATED SIDEWALK ENTRY SECONDARY UNIT ENTRY MAIN HOUSE ELEVATOR TANK & CONTROL ROOF DRAINAGE FD CO CO RADON MITIGATION LINE FOUNDATION /STORM DRAIN LINESOFFITPEX MANIFOLDSPROPOSED METERLOCATIONSIN-GROUND HOT TUB HEATED PATIO SANITARY SEWER LINE GARAGE 122 CONC-1 Install:LC A: 783 sq ft MECH RM 102 CONC-2 Install:LC A: 88 sq ft BEDROOM 2 111 CPT-1 Install:LC A: 140 sq ft FOYER 101 S-1 Install:LC A: 179 sq ft STORAGE 103 S-1 Install:LC A: 66 sq ft FOYER 104 S-1 Install:LC A: 60 sq ft HALL 108 EWP-1 Install:LC A: 59 sq ft LAUNDRY 110 S-1 Install:LC A: 10 sq ft BATH 114 S-1 Install:LC A: 55 sq ft HALL 115 S-1 Install:LC A: 62 sq ft MEDIA ROOM 119 CPT-1 Install:LC A: 234 sq ft SAUNA 121 CONC-1 Install:LC A: 42 sq ft MECH RM 113 CONC-2 Install:LC A: 32 sq ft ELEVATOR 100 S-1 Install:LC A: 17 sq ft OFFICE 116 CPT-1 Install:LC A: 150 sq ft PATIO PAVERS A: 260 sq ft BEDROOM 1 106 CPT-1 Install:LC A: 165 sq ft GYM 120 RF-1 Install:LC A: 227 sq ft LIVING 105 EWP Install:LC A: 320 sq ft MUD ROOM 117 S-1 Install:LC A: 53 sq ft STORAGE 123 CONC-1 Install:LC A: 167 sq ft P1 P1.10 P2 P1.10 P3 P1.10 4" PVC STACK TO CONNECT TO PVC STACK ABOVE 2" S 2" S VERIFY METER LOCATIONS FOR WATER, ELEC, AND GAS WITH UTILITIES. DHW DHW DHW 2" Invert: -2'-1" Invert: -2'-101/8" Invert: -2'-93/8" Invert: -2'-2" Invert: -2'-111/8" PROVIDE (1) 2" CONDUIT FOR EACH MASTER SUITE FOR O2 LINES. UP 16R UP 7R DN 4R UP 3R NICHE NICHE HOSE BIB HOSE BIB HOSE BIB HOSE BIB SCUPPER ABOVEUP 2RFLOOR DRAIN STAIR INFO TREADS : 11-1/4" RISERS : 7-1/4" BATH 112 S-1 Install:LC A: 54 sq ft BATH 107 S-1 Install:LC A: 39 sq ft PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 01 - WIP.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 07 Plumbing System Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Floor Drain/Waste Plan Drawing: First Floor Drain/Waste Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: DW DWF 3" S WINDOW ABV.; SILL HEIGHT 5'11"WINE COOLERELEVATOR CAB 40"x54" CLEAR INTERIOR BUILT-IN CLOSET SYSTEM DN DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT CLEAR GL.MWFROSTED GLHOSE BIB HOSE BIB DOWN SPOUT SCUPPER M1Z:1,2M2Z:1M3Z:1 M4Z:3WALLOVEN COFFEE HOSEBIBLIVING ROOM 202 EWP Install:LC A: 587 sq ft FOYER 201 S-1 Install:LC A: 149 sq ft KITCHEN 203 EWP Install:LC A: 238 sq ft DINING 204 EWP Install:LC A: 225 sq ft PANTRY 205 EWP Install:LC A: 84 sq ft H: 8.42' STAIR 206 S-1 Install:LC A: 34 sq ft HALL 207 S-1 Install:LC A: 43 sq ft WC 208 S-1 Install:LC A: 36 sq ft MASTER BED 210 EWP Install:LC A: 223 sq ft DECK Dasso A: 133 sq ft DECK Dasso A: 59 sq ft STEAM SHW 211A T-2 Install:MC A: 28 sq ft MASTER BATH 211 S-1 Install:MC A: 196 sq ft DECK Dasso A: 617 sq ft WIC 212 EWP Install:LC A: 65 sq ft P1 P1.10 P2 P1.10 P3 P1.10 F 2" S 1" S 1 1/2" S 3" S 1 1/2" S 1 1/2" S 2" S 1 1/2" S 3" S 2" S UP 18R DN 7R STEAMGENERATORNICHES-01 BENCH w/ STONE SLAB TOPDN 6R DN 4R STAIR INFO: TREAD : 12" RISER : 6-7/8" UP 3R PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS.5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 07 Plumbing System Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Second Floor Drain/Waste Plan Drawing: Second Floor Drain/Waste Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: P1 P1.10 P2 P1.10 P3 P1.10 2" S 3" S 1 1/2" S 2" S 3" S 1 1/2" S T-5 ROD & SHELF ROD & SHELF BUILT-IN CLOSET SYSTEM DOWN SPOUT DOWN SPOUT BUILT-IN LINENW/DOORSWINDOW ABV.; SILL HEIGHT 5'11"CLEAR GL.FROSTED GLM8Z:7M7Z:4M5Z:5 M6Z:6 FOYER 301 CPT-? Install:LC A: 144 sq ft GALLERY 302 CPT-? Install:LC A: 187 sq ft BEDROOM 3 304 CPT-? Install:LC A: 201 sq ft BEDROOM 4 307 CPT-? Install:LC A: 201 sq ft MASTER BED 2 310 CPT-? Install:LC A: 223 sq ft WIC 312 CPT-? Install:LC A: 65 sq ftLAUNDRY 313 S-1 Install:MC A: 81 sq ftSTAIR 314 EWP Install:LC A: 39 sq ft VOID A: 409 sq ft WIC 308 CPT-? Install:LC A: 20 sq ft WIC 305 CPT-? Install:LC A: 20 sq ft MASTER BATH 311 S-1 Install:MC A: 197 sq ft STEAM SHW 311A T-2 Install:MC A: 26 sq ft SHOWER 309A T-2 Install:MC A: 15 sq ft BATH 309 S-1 Install:MC A: 44 sq ft BATH 306 S-1 Install:MC A: 44 sq ft SHOWER 306A T-2 Install:MC A: 15 sq ft PROVIDE CONDENSATE DRAIN FROM STEAM GENERATOR ROOF DRAIN LINE THROUGH WALL AND INTO DRAIN STACK. 2" S 3" S 1" S 2" S 3" S 2" S 1 1/2" S 3" S DN 18R GENERATORDOWN SPOUT NICHES-01 BENCH w/ STONE SLAB TOPSTAIR INFO: TREAD : 12" RISER : 6-7/8" DECK Dasso A: 69 sq ft DECK Dasso A: 80 sq ft PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 8. FIRST AND SECOND FLOOR PLUMBING PLANS FOR REFERENCE ONLY. SEE MC SHOP DRAWINGS FOR FINAL LAYOUTS.5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 07 Plumbing System Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: DWV Isometric Drawing: DWV Isometric Scale: 3/8" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: X" C X" P 4" P 4" P 4" P 4" C 4" C 3" P 3" P 3" P 3" P 3" P 1 1/2" P2" P 2" P 3" P 3" P 1 1/2" P 2" P 4" P 4" P 2" P 3" P 3" P 1 1/2" P 3" P 3" C 3" P4" P 2" P2" P 2" P 1" P 1" P 2" P 3" P 3" P 3" P 4" P 1 1/2" P 3" P 3" P 3" P 1 1/2" P 2" P 1 1/2" P 1 1/2" P 1 1/2" P 1 1/2" P 1 1/2" P1 1/2" P 1 1/2" P 1 1/2" P WC/ IW IN WALL CARRIER FOR WATER CLOSET. X" P PVC LINE, SIZE AS INDICATED X" C CAST IRON LINE, SIZE AS INDICATED XFU CUMULATIVE FIXTURE UNITS AT THIS LOCATION FLOOR PENETRATION KS KITCHEN SINK CO CLEANOUT WSR CLOTHES WASHER UR URINAL WC FLOOR MOUNTED WATER CLOSET. SANITARY LINE, SIZE AND MATERIAL AS INDICATED (P=PVC, C= CAST IRON) VENT LINE, SIZE AND MATERIAL AS INDICATED (P=PVC, C= CAST IRON) 2FU 3FU 2FU 0FU 5FU 8FU 10FU 10FU 20FU 1FU 3FU 4FU 24FU 26FU 28FU 29FU 3FU 1FU 2FU 6FU 1FU 7FU 1FU 2FU 5FU6FU8FU15FU 17FU 20FU 21FU50FU 52FU 3FU 6FU 6FU 2FU 2FU 10FU 10FU 6FU 16FU 68FU WC/ IW WC/ IW KS LAV LAV KS KS TUB WC WC WC WC LAV LAV LAV LAV LAV LAV UR UR CL CL CONDENSATE LINE SHR SHR SHOWER SHR CO CL CL SHRWC LAV WSR SHR 3" VTR 3" VTR WSR WC CO FD SHR SHRWSR FD 3" VTR AAV AAV AIR ADMITANCE VALVE 5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES Work in P rogressRevID ChID Change Name Date 01 - WIP 07 Plumbing System Changes Work in Progress evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.06 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Basement Plumbing Supply Plan Drawing: Basement Plumbing Supply Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 122.1 (DR)(t) 113.17'3'106.17'2'-8"106.2110.17' 2'-8" 111.17'2'-8"115.1 6'-8" 3'116.27' 2' 106.2 (TT/FX)(E)120.1 (TTd)120.2 (TT/FX/TT) 116.1 (FX/TT) 111.1 (FX/TT)(E) 107.26'-5" 2'-5 1/2" 107.17' 2'-6" 104.1 (DR)(t) 105.1 (TT/FX)105.2 (TT/FX) 106.1 (TT)(t)122.27'-6" 9'122.3 7'-6" 9'122.4 7'-6" 9' 111.2105.17' 3'112.17' 2'-6" 114.17'3'101.1 7'2'-8"119.17' 2'-8" 117.17'2'-4"123.16'-8"3'120.17'2'-8"DWF 112.26'-5"2'-5 1/2" BOILER BOILER UH 1 SUGGESTED PEX MANIFOLD LOCATIONS 2" SPRINKLER WATER IN (GALV STEEL OR COPPER) FIRE CAULK OR USE APPROPRIATE COLLARS FOR PENETRATIONS IN RATED ASSEMBLIES (CEILING OVER APARTMENT IS REQUIRED TO BE 30 MIN RATED) CONNECT GAS LINE UP TO UPSTAIRS LAUNDRY (2) O2 Gen STACKED O2 Gen CONNECT GAS LINE TO HOT TUB, VERIFY WITH MANUFACTURER SPECIFICATIONS CONNECT GAS LINE UP TO FIRE FEATURE BOILER LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE HEATED DRIVEWAY DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT HEATED SIDEWALK ENTRY SECONDARY UNIT ENTRY MAIN HOUSE ELEVATOR TANK & CONTROL ROOF DRAINAGE 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLDSOFFIT 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD PEX MANIFOLDSPROPOSED METERLOCATIONSIN-GROUND HOT TUB HEATED PATIO GARAGE 122 CONC-1 Install:LC A: 783 sq ft MECH RM 102 CONC-2 Install:LC A: 88 sq ft BEDROOM 2 111 CPT-1 Install:LC A: 140 sq ft FOYER 101 S-1 Install:LC A: 179 sq ft STORAGE 103 S-1 Install:LC A: 66 sq ft FOYER 104 S-1 Install:LC A: 60 sq ft HALL 108 EWP-1 Install:LC A: 59 sq ft LAUNDRY 110 S-1 Install:LC A: 10 sq ft BATH 114 S-1 Install:LC A: 55 sq ft HALL 115 S-1 Install:LC A: 62 sq ft MEDIA ROOM 119 CPT-1 Install:LC A: 234 sq ft SAUNA 121 CONC-1 Install:LC A: 42 sq ft MECH RM 113 CONC-2 Install:LC A: 32 sq ft ELEVATOR 100 S-1 Install:LC A: 17 sq ft OFFICE 116 CPT-1 Install:LC A: 150 sq ft PATIO PAVERS A: 260 sq ft BEDROOM 1 106 CPT-1 Install:LC A: 165 sq ft GYM 120 RF-1 Install:LC A: 227 sq ft LIVING 105 EWP Install:LC A: 320 sq ft MUD ROOM 117 S-1 Install:LC A: 53 sq ft STORAGE 123 CONC-1 Install:LC A: 167 sq ft 102.17' 3' 116.1 7'2'-8"1" DOMESTIC WATER IN (COPPER) VERIFY METER LOCATIONS FOR WATER, ELEC, AND GAS WITH UTILITIES. DHW DHW DHW UP 16R UP 7R DN 4R UP 3R NICHE 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 3/4" PEX IN 3/4" PEX OUT TO MANIFOLD SUPPLY Domestic Cold Water Domestic Hot Water NOTE: WATER FOR APARTMENT IS NOT SUBMETERED, FEEDS ARE DIRECT FROM MAIN HOUSE LINES. NICHE HOSE BIB HOSE BIB HOSE BIB HOSE BIB SCUPPER ABOVE 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD UP 2RFLOOR DRAIN STAIR INFO TREADS : 11-1/4" RISERS : 7-1/4" BATH 112 S-1 Install:LC A: 54 sq ft BATH 107 S-1 Install:LC A: 39 sq ft PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 01 - WIP.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 07 Plumbing System Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.07 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Level Plumbing Supply Plan Drawing: First Level Plumbing Supply Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions:6/25/18Date printed: 203.2(TT/FX/TT) 205.1 (FX/TT) 201.1 (DR/FX)(t) 206.1 (FX) 208.1 (FX) 211.2 (TT FX)(t)210.17' 3' 211.1 7'3'203.1 (LS)(t)211.2 6'-11 1/2"2'-11"211A.1 6'-5"2'-11"208.17'2'-8"207.1 7' 2'-6"207.17' 3'-4" 209.1 (TT/FX/FX)(t)203.27'-3 1/2" 6'DW DWF 209.2 (TT)(t)202.2b (FX)(t) 202.2a (TT/FX)(t)202.3a (FX)(t) 202.3b (TT/FX)(t) 204.1 (LS)(t)WINDOW ABV.; SILL HEIGHT 5'11"WINE COOLERELEVATOR CAB 40"x54" CLEAR INTERIOR BUILT-IN CLOSET SYSTEM DN DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT CLEAR GL.MWFROSTED GLHOSE BIB HOSE BIB DOWN SPOUT SCUPPER WALLOVEN COFFEE HOSEBIBLIVING ROOM 202 EWP Install:LC A: 587 sq ft FOYER 201 S-1 Install:LC A: 149 sq ftKITCHEN 203 EWP Install:LC A: 238 sq ft DINING 204 EWP Install:LC A: 225 sq ft PANTRY 205 EWP Install:LC A: 84 sq ft H: 8.42' STAIR 206 S-1 Install:LC A: 34 sq ft HALL 207 S-1 Install:LC A: 43 sq ft WC 208 S-1 Install:LC A: 36 sq ft MASTER BED 210 EWP Install:LC A: 223 sq ft DECK Dasso A: 133 sq ft DECK Dasso A: 59 sq ft STEAM SHW 211A T-2 Install:MC A: 28 sq ft MASTER BATH 211 S-1 Install:MC A: 196 sq ft DECK Dasso A: 617 sq ft WIC 212 EWP Install:LC A: 65 sq ft F 202.1 (TT/FX/FX)(t)211.1 (FX)(t)209.3 (LS)(t)STEAM SHOWER GENERATOR: INPUT: 3/8 NPT STEAM OUTLET: 1/2" NPT DRAIN: 1/2" NPT SAFETY VALVE: 3/4" NPT ELEC: 240V 1/2" STEEL NPT TO STEAM HEAD. DO NOT RUN IN EXTERIOR WALL. INSULATE PER MANUFACTURER'S RECOMMENDATIONS. FIRE SPRINKLER PIPING PER SPRINKLER COMPANY SHOP DRAWINGS. LEAVE OFF DRYWALL SUFFICIENT FOR ONSITE INSPECTION BY VAIL BUILDING DEPARTMENT. FIRE SPRINKLER HEAD. SEE RCP FOR LOCATION. (TYP)UP 18R DN 7R STEAMGENERATORNICHES-01 BENCH w/ STONE SLAB TOPDN 6R DN 4R 1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 3/8" COPPER TO ICE MAKERS 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD (STEAM OVEN)1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD STAIR INFO: TREAD : 12" RISER : 6-7/8" UP 3R PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 8. FIRST AND SECOND FLOOR PLUMBING PLANS FOR REFERENCE ONLY. SEE MC SHOP DRAWINGS FOR FINAL LAYOUTS. 5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 07 Plumbing System Changes 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.08 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Second Floor Plumbing Supply Plan Drawing: Second Floor Plumbing Supply Plan Scale: 1/4" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 304.1 (TT/FX)(t) 303.3 (FX) 303.2 (FX/FX) 304.2 (FX/TT/FX)(E)(t) 307.1 (FX/TT/FX)(E)(t)307.2 (TT/FX)(t) 301.1 (FX/FX)(t) 304.17'2'-8"307.17'2'-8"311.2 (TT FX)(t) 310.1 (TT/FX/FX)(t) 309.17'2'-8"309.26'-5"2'-5 1/2"306.1 7' 2'-8"306.2 6'-5"2'-5 1/2"311A.1 6'-5"2'-11"311.26'-11 1/2"2'-11"310.17' 3' 311.1 7'3'313.1 (FX)314.1 (FX) 313.17'2'-8"305.17' 2'-6"308.17' 2'-6"310.2 (TTd)(E)(t)303.1 (FX/FX)302.1 (LS)(t)T-5 ROD & SHELF ROD & SHELF BUILT-IN CLOSET SYSTEM DOWN SPOUT DOWN SPOUT BUILT-IN LINENW/DOORSWINDOW ABV.; SILL HEIGHT 5'11"CLEAR GL.FROSTED GLFOYER 301 CPT-? Install:LC A: 144 sq ft GALLERY 302 CPT-? Install:LC A: 187 sq ft BEDROOM 3 304 CPT-? Install:LC A: 201 sq ft BEDROOM 4 307 CPT-? Install:LC A: 201 sq ft MASTER BED 2 310 CPT-? Install:LC A: 223 sq ft WIC 312 CPT-? Install:LC A: 65 sq ftLAUNDRY 313 S-1 Install:MC A: 81 sq ftSTAIR 314 EWP Install:LC A: 39 sq ft VOID A: 409 sq ft WIC 308 CPT-? Install:LC A: 20 sq ft WIC 305 CPT-? Install:LC A: 20 sq ft MASTER BATH 311 S-1 Install:MC A: 197 sq ft STEAM SHW 311A T-2 Install:MC A: 26 sq ft SHOWER 309A T-2 Install:MC A: 15 sq ft BATH 309 S-1 Install:MC A: 44 sq ft BATH 306 S-1 Install:MC A: 44 sq ft SHOWER 306A T-2 Install:MC A: 15 sq ft 311.1 (FX) 310.3 (FX/FX)(t)STEAM SHOWER GENERATOR: INPUT: 3/8 NPT STEAM OUTLET: 1/2" NPT DRAIN: 1/2" NPT SAFETY VALVE: 3/4" NPT ELEC: 240V 1/2" STEEL NPT TO STEAM HEAD. DO NOT RUN IN EXTERIOR WALL. INSULATE. DN 18R GENERATORDOWN SPOUT 1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TOMANIFOLD1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD 1/2" PEX TO MANIFOLD NICHES-01 BENCH w/ STONE SLAB TOPSTAIR INFO: TREAD : 12" RISER : 6-7/8" DECK Dasso A: 69 sq ft DECK Dasso A: 80 sq ft PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 8. FIRST AND SECOND FLOOR PLUMBING PLANS FOR REFERENCE ONLY. SEE MC SHOP DRAWINGS FOR FINAL LAYOUTS. 5.07 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES W ork in P rogressRevID ChID Change Name Date 01 - WIP 07 Plumbing System Changes Work in Progress evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P1.10 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Plumbing Sections Drawing: Plumbing Sections Scale: 1/8" = 1'-0", 1' = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: -4.71' -1 Top of Footing (Main House) ±0.00' 1 BSMT/Garden Level +9.63' 2 First Floor +19.86' 3 Second Floor +29.22' 4 Roof 9'-23/4"5'-31/8" 27'-67/8" 5'-2" 2'-8" -4.71' -1 Top of Footing (Main House) -4.71' -1 Top of Footing ±0.00' 1 BSMT/Garden Level ±0.00' 1 BSMT/Garden +9.63' 2 First Floor +9.63' 2 First Floor +19.86' 3 Second Floor +19.86' 3 Second Floor +29.22' 4 Roof +29.22' 4 Roof 2'-8" 5'-2" 27'-67/8" 5'-31/8" 9'-23/4" INTERNAL ROOF DRAIN IN CHASE BEYOND VENT THROUGH ROOF BEYOND UNDER SLAB SANITARY LINES VENT THROUGH ROOF BEYOND -4.71' -1 Top of Footing (Main House) ±0.00' 1 BSMT/Garden Level +9.63' 2 First Floor +19.86' 3 Second Floor +29.22' 4 Roof DROPPED CEILING IN BEDROOM RADON VENT PIPING BEYOND RADON VENT PIPING THROUGH ROOF, BEYOND VENT THROUGH ROOF PLUMBING NOTES: 1. INSULATE ALL HOT WATER PIPING (R-3 MINIMUM) 2. ALL SUPPLY LINES SHALL BE PEX, WITH HOME RUNS BACK TO MANIFOLD 3. PROVIDE NEAT AND ORDERLY PIPING TO MANIFOLD. 4. PROVIDE CAST IRON STACK PIPING IN LOCATIONS INDICATED ON BASEMENT DWV PLAN (FOR ACOUSTICS.) 5. SEE MECHANICAL PLANS FOR GAS LINE PIPING. 6. SEE ISOMETRICS FOR SANITARY LINE PIPE SIZING. 7. VERIFY ANY INVERTS INDICATED ON PLUMBING PLANS WITH CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 8. FIRST AND SECOND FLOOR PLUMBING PLANS FOR REFERENCE ONLY. SEE MC SHOP DRAWINGS FOR FINAL LAYOUTS. 01 - WIP.07 SCALE: 1/8" = 1'-0" 1 Plumbing Section 1 P1.10 SCALE: 1/8" = 1'-0" 2 Plumbing Section 2 P1.10 SCALE: 1/8" = 1'-0" 3 Plumbing Section 3 P1.10 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: P6.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Plumbing Schedule Drawing: Plumbing Schedule Scale: 1:1.61 CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: PLUMBING FIXTURES & ACCESSORIES Location BSMT/Garden Level, , BSMT/Garden Level, 102, MECH RM BSMT/Garden Level, 105, LIVING BSMT/Garden Level, 106, BEDROOM 1 BSMT/Garden Level, 107, BATH BSMT/Garden Level, 112, BATH BSMT/Garden Level, 114, BATH 2D Symbol Description Hose Bib Floor Drain Faucet w/ Dual Spray Pull-out Garbage Disposal Sink, Single Bowl Undermount Soap Dispenser Floor Cleanout Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Floor Mounted Toilet Shower Arm Shower Drain Shower Head, fixed Shower Kit Sink, Undermount Thermostatic Rough Thermostatic Trim Toilet Seat Volume Control Rough Volume Control Trim Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Floor Cleanout Floor Mounted Toilet Shower Arm Shower Drain Shower Head, fixed Shower Kit Sink, Undermount Thermostatic Rough Thermostatic Trim Toilet Seat Volume Control Rough Volume Control Trim Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Floor Mounted Toilet Shower Arm Shower Head, fixed Sink, Undermount Thermostatic Rough Thermostatic Trim Toilet Seat Tub Tub Filler, Wall mount Volume Control Rough Qty 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 4 1 1 1 1 1 1 1 1 1 1 1 1 2 Mfg. By Contractor Grohe InSinkErator Franke Grohe Gedy Gedy Artos Jaclo Toto Grohe California Faucets Grohe Artos Wet Style Artos Artos Toto Artos Artos Gedy Gedy Artos Jaclo Toto Grohe California Faucets Grohe Artos Wet Style Artos Artos Toto Artos Artos Gedy Gedy Artos Jaclo Toto Grohe Grohe Wet Style Artos Artos Toto Duravit Artos Artos Product/ Series Minta HP Garbage Disposal Cosmopolitan G-Demetra G-Demetra Decorative round Maris Mission, Style Drain Rainshower Cube Collection Opera SoftClose G-Demetra G-Demetra Decorative round Maris Mission, Style Drain Rainshower Cube Collection Opera SoftClose G-Demetra G-Demetra Decorative round Maris Rainshower Cube Collection Opera SoftClose Opera Color/Finish Polished Chrome Starlight chorme Stainless Steel Polished chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome White Polished Chrome Polished Chrome Polished Chrome Polished Chrome Glossy White 3/4" Polished Chrome White 1/2" Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome Standard White Polished Chrome Polished Chrome Polished Chrome Polished Chrome Glossy White 3/4" Polished Chrome White 1/2" Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome Standard White Polished Chrome Polished Chrome Glossy White 3/4" Polished Chrome White Polished Chrome 1/2" Type/Item # 32319 PRO880 7/8 FSUG800 40535000 5127 5124 F501-3-1-Ch 225-PCH CST484CEMFG 28577000 9172-PVC 27135000 F907-15 VC 821U-0-PC-G F904A-VO F904-5TK SS114#1 F906A-VO F906A-5TK 5127 5124 F501-3-1-Ch 225-PCH CST484CEMFG 28577000 9172-PVC 27135000 F907-15 VC 821U-0-PC-G F904A-VO F904-5TK SS114#1 F906A-VO F906A-5TK 5127 5124 F501-3-1-Ch 225-PCH CST484CEMFG 28577000 27135000 VC 821U-0-PC-G F904A-VO F904-5TK SS114#1 F908-3 F906A-VO Note/Remarks Square, with trap primer Include (1) Franke 906 Strainer basket unit in chrome when ordering sink PVC 2"/3" 7.75" top to bottom of bottle, ±13" wall to front of bottle Elongated Bowl, 3D Tornado PVC 2"/3" For use with floor mounted elongated bowl 7.75" top to bottom of bottle, ±13" wall to front of bottle PVC 2"/3" Elongated Bowl, 3D Tornado PVC 2"/3" For use with floor mounted elongated bowl 7.75" top to bottom of bottle, ±13" wall to front of bottle Elongated Bowl, 3D Tornado For use with floor mounted elongated bowl Extended max 10", min 8" Suppplied By LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC Installed By LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC LC PLUMBING FIXTURES & ACCESSORIES Location BSMT/Garden Level, 120, GYM BSMT/Garden Level, 122, GARAGE First Floor, , DECK First Floor, , First Floor, 203, KITCHEN First Floor, 205, PANTRY First Floor, 208, WC First Floor, 211, MASTER BATH First Floor, 211A, STEAM SHW Second Floor, 306, BATH Second Floor, 306A, SHOWER 2D Symbol Description Volume Control Trim Floor Drain Hose Bib Hose Bib Hose Bib Hose Bib Faucet w/ Dual Spray Pull-out Garbage Disposal Sink, Single Bowl Undermount Faucet w/ Dual Spray Pull-out Sink, Single Bowl Undermount Accessory, Toilet paper holder Faucet, Wall mount Sink, Undermount Toilet Seat Toilet, Actuator Toilet, In Wall Tank Toilet, Wall Hung Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Recessed Medicine Cabinet Toilet Seat Toilet, Actuator Toilet, In-wall carrier Toilet, Wall Hung Urinal Urinal, Actuator Urinal, In-wall carrier Wash Basin, Undermount Fixed Shower Head Shower Arm Shower Drain Shower Kit Steam Shower Control and Head Thermostatic Rough Thermostatic Trim Volume Control Rough Volume Control Trim Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Floor Mounted Toilet Recessed Medicine Cabinet Sink, Undermount Toilet Seat Qty 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 1 Mfg. Artos By Contractor Grohe InSinkErator Home Refinements Grohe Franke Gedy Artos Wet Style Toto Geberit Geberit Toto Gedy Gedy Artos Jaclo Century Bathworks Toto Geberit Geberit Toto Duravit Geberit Geberit Wet Style Grohe Grohe California Faucets Artos Mr Steam Artos Artos Artos Artos Gedy Gedy Artos Jaclo Toto Century Bathworks Wet Style Toto Product/ Series K7 HP Garbage Disposal Julian, Urban Edge Minta G-Demetra Opera Cube Collection SoftClose Sigma30 Duofix Maris G-Demetra G-Demetra Opera Decorative round 19"x4"x40" SoftClose Sigma30 Duofix MH Wall Hung Toilet Durastyle Bolero Duofix Cube Collection Rainshower Cosmopolitan 160 Rainshower Mission, Style Drain Ms Butler Opera G-Demetra G-Demetra Opera Decorative round Maris 15"x4"x40" Cube Collection SoftClose Color/Finish Polished Chrome Polished Chrome Polished Chrome Stainless Steel Polished Chrome Stainless Steel Polished Chrome Polished Chrome Glossy White White White-Polished Chrome-White StandardWhite Polished Chrome Polished Chrome Polished Chrome Polished Chrome Satin finish White White-Polished Chrome-White Standard White White Alpine White Glossy White Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome 3/4" Polished Chrome 1/2" Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome Standard White Satin Finish Glossy White White Type/Item # F906A-5TK 31380 PRO880 7/8 3634-DW1-DP3 32319 FSUG800-20BX 5124 F501-7-1CH VC 821U-0-PC-G SS117#1 115.883.KJ.1 111.335.00.5 CT486FG 5127 5124 F501-3-1CH 225-PCH 1940-4-SF-B-O-O-O SS117#1 115.883.KJ.1 111.335.00.5 CT437FG 2806300092 116.012.11 111.625.00.1 VC 848U-0-PC-G 27135000 28577000 9172-PVC F907-15 1RD-PC F904A-VO F904-5TK F906A-VO F906A-5TK 5127 5124 F501-3-1CH 225-PCH CST484CEMFG 1540-4-SF-B-O-O-O VC 848U-0-PC-G SS114#1 Note/Remarks Square, with trap primer 40.25" x 19.5" x 10", Include (1) Franke 906 Strainer basket unit in chrome when ordering sink Include (1) Franke 906 Strainer basket unit in chrome when ordering sink MC installs valve body. LC installs spout and handles after tile is grouted. Operating pressure 75 psi For use with wall hung toilet 7.75" top to bottom of bottle, ±13" wall to front of bottle MC to frame rough opening 18.25" x 39.375" For use with wall hung toilet Dual Button 11.25" shower arm PVC 2"/3" Include eTempo Plus control, steam head, 7.75" top to bottom of bottle, ±13" wall to front of bottle Elongated Bowl, 3D Tornado MC to frame niche 14.25" wide x 39.375" high For use with floor mounted elongated bowl Suppplied By LC LC LC LC LC LC LC LC MC LC MC LC MC LC LC MC MC MC LC LC LC LC LC LC MC MC MC MC MC MC LC LC LC MC LC LC MC LC MC LC LC LC LC LC MC LC LC LC Installed By LC LC LC LC LC LC LC LC LC LC LC LC MC/LC LC LC LC MC MC LC LC LC LC LC LC LC MC MC MC LC MC LC LC LC MC LC LC MC LC MC LC LC LC LC LC MC LC LC LC PLUMBING FIXTURES & ACCESSORIES Location Second Floor, 309, BATH Second Floor, 309A, SHOWER Second Floor, 311, MASTER BATH Second Floor, 311A, STEAM SHW Second Floor, 313, LAUNDRY 2D Symbol Description Fixed Shower Head Shower Arm Shower Drain Shower Kit Thermostatic Rough Thermostatic Trim Volume Control Rough Volume Control Trim Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Floor Mounted Toilet Recessed Medicine Cabinet Sink, Undermount Toilet Seat Fixed Shower Head Shower Arm Shower Drain Shower Kit Thermostatic Rough Thermostatic Trim Volume Control Rough Volume Control Trim Accessory, Robe hook Accessory, Toilet paper holder Faucet Faucet, Trap Recessed Medicine Cabinet Sink, Undermount Toilet Seat Toilet, Actuator Toilet, In-wall carrier Toilet, Wall Hung Urinal Urinal, Actuator Urinal, In-wall carrier Fixed Shower Head Shower Arm Shower Drain Shower Kit Steam Shower Control and Head Thermostatic Rough Thermostatic Trim Volume Control Rough Volume Control Trim Faucet w/ Dual Spray Pull-out Sink, Single Bowl Undermount Qty 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 4 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 Mfg. Grohe Grohe California Faucets Artos Artos Artos Artos Artos Gedy Gedy Artos Jaclo Toto Century Bathworks Wet Style Toto Grohe Grohe California Faucets Artos Artos Artos Artos Artos Gedy Gedy Artos Jaclo Century Bathworks Wet Style Toto Geberit Geberit Toto Duravit Geberit Geberit Grohe Grohe California Faucets Artos Mr Steam Artos Artos Artos Artos Grohe Franke Product/ Series Rainshower Cosmopolitan 160 Rainshower Mission, Style Drain Opera G-Demetra G-Demetra Opera Decorative round Maris 15"x4"x40" Cube Collection SoftClose Rainshower Cosmopolitan 160 Rainshower Mission, Style Drain Opera G-Demetra G-Demetra Opera Decorative round 19"x4"x40" Cube Collection SoftClose Sigma30 Duofix MH Wall Hung Toilet Durastyle Bolero Duofix Rainshower Cosmopolitan 160 Rainshower Mission, Style Drain Ms Butler Opera Minta Color/Finish Polished Chrome Polished Chrome Polished Chrome Polished Chrome 3/4" Polished Chrome 1/2" Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome Standard White Satin Finish Glossy White White Polished Chrome Polished Chrome Polished Chrome Polished Chrome 3/4" Polished Chrome 1/2" Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome Satin finish Glossy White White White-Polished Chrome-White Standard White White Alpine White Polished Chrome Polished Chrome Polished Chrome Polished Chrome Polished Chrome 3/4" Polished Chrome 1/2" Polished Chrome Polished Chrome Stainless Steel Type/Item # 27135000 28577000 9172-PVC F907-15 F904A-VO F904-5TK F906A-VO F906A-5TK 5127 5124 F501-3-1CH 225-PCH CST484CEMFG 1540-4-SF-B-O-O-O VC 848U-0-PC-G SS114#1 27135000 28577000 9172-PVC F907-15 F904A-VO F904-5TK F906A-VO F906A-5TK 5127 5124 F501-3-1CH 225-PCH 1940-4-SF-B-O-O-O VC 848U-0-PC-G SS117#1 115.883.KJ.1 111.335.00.5 CT437FG 2806300092 116.012.11 111.625.00.1 27135000 28577000 9172-PVC F907-15 1RD-PC F904A-VO F904-5TK F906A-VO F906A-5TK 32319 FSUG800-20BX Note/Remarks 11.25" shower arm PVC 2"/3" 7.75" top to bottom of bottle, ±13" wall to front of bottle Elongated Bowl, 3D Tornado MC to frame niche 14.25" wide x 39.375" high For use with floor mounted elongated bowl 11.25" shower arm PVC 2"/3" 7.75" top to bottom of bottle, ±13" wall to front of bottle MC to frame niche 18.25" wide x 39.375" high For use with wall hung toilet Dual Button 11.25" shower arm PVC 2"/3" Include eTempo Plus control, steam head, Include (1) Franke 906 Strainer basket unit in chrome when ordering sink Suppplied By LC LC MC LC MC LC MC LC LC LC LC LC MC LC LC LC LC LC MC LC MC LC MC LC LC LC LC LC LC LC LC MC MC MC MC MC MC LC LC MC LC LC MC LC MC LC LC MC Installed By LC LC MC LC MC LC MC LC LC LC LC LC MC LC LC LC LC LC MC LC MC LC MC LC LC LC LC LC LC LC LC LC MC MC MC LC MC LC LC MC LC LC MC LC MC LC LC LC 10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 2:45:39 PM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 2:47:32 PM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 2:44:55 PM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live A1 R A1 R A1 R A1 R A1R A1 R A1R A1R A1R A1 R A1 R A1 R A1R A1 R A1 R A1 R A1R A1 R A1R A1R A1R A1R A1R A1R A1R A1R A1R A1RA1R A1R A1R A1R A1R A1R A1R A1R A1R A1R A1 R A1 R A1 R A1R A1 R A1R A1R A3 R A1R A1R A1R A1 R A1 R A1RA1R A1 R A1 R A1R A1 R A1 R A1 R A1 R A1R A1 R A1R A1R A1R A1 R A1 R A1R A1R A1 R A1 R A1 R A1R A1R A1 R A1R A1R A1R Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :22:25 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live A1 R A1 R A1 R A1R A1 R A1R A1R A3 R A1R A1R A1R A1 R A1R A1 R A1 R A1R A1 R A1 R A1 R A1 R A1R A1 R A1R A1R A1R A1 R A1 R A1R A1R A1 R A1 R A1 R A1R A1R A1 R A1R A2R A2 R A2 R A2 R A2 R A2 R A1R A1R A1 R A1 R A3 R A1R A1R A1R A1R A3 R Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :22:51 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :09:49 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 0:31 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :47:35 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 0:58 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 1 :21 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 6:28 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 8:25 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 3:04 AM10/11/18 STRUCTURAL MODULARS, INC. Design * Construct * Live Z:\Q3593 EvoDomus-Sturm\Q3593.dwg, 1 2/1 9/201 7 1 1 :1 4:02 AM10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: S.01 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Footing plan Drawing: Footing plan Scale: 1/4" = 1'-0", 1:1.33, 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/26/18 Date printed: 12'-113/8" 2'-6" 10'-10 7/8"3'-0" 11'-0" 3'-0" 12'-9" 3'-0" 21'-57/8"2'-0" 3'-0" 11'-67/8" 4'-0"2'-0" 8'-75/8" 4'-0" 3'-85/8" 4'-0" 14'-91/2"2'-0" 5'-111/4" 26'-6" 2'-81/2"2'-0" 5'-81/8" 14'-0" 5'-85/8" 3'-0" 6'-9" 6'-83/4" 2'-0" 2'-0" 6'-8" 2'-0" 6'-33/8" 2'-0" 8'-111/8" 3'-0" 13'-01/2" 3'-0"1'-33/4"3'-0" 9'-71/8" 2'-0"2'-0" 9'-103/4" 17'-11/4" 14'-101/2" 2'-0"2'-0" 21'-31/8" 5" 10'-53/8" 5" 12'-111/2" 2'-113/8" 2'-0" 26'-55/8"2'-83/8" 2'-0"14'-01/4" 21'-6" 44'-41/2" 40'-25/8" 15'-4" 10'-13/4" 29'-0" 6'-83/4"45'-101/2"14'-21/8" 4'-71/8" 32'-43/4" 2'-0" 6'-81/4" 2'-0" 41'-61/8" 5" 5'-55/8"5"5"6'-81/2"5"2'-0" 41'-101/2" 2'-0"2'-67/8" 2'-0" 9'-4" 2'-0"6'-6"19'-91/2" 4'-47/8" 2'-0"2 5 ' - 6 1/ 2 " 2'-0" 6'-1 3/4"2'-0" 4'-01/4" 4'-6"7'-111/2" 2'-0"8'-11/4" 2'-0"2'-83/8" 2'-0" 12'-01/4" 2'-0" 21'-6"6'-4" 2'-0"37'-25/8" 16'-1"3'-6"1'-0"1'-0" 8" 8" 7'-53/4" 8" 8"8"8"8"4'-01/4" 8" 8" 8" 3'-2" -0.00'(8,592.08')-0.38'(8,591.71') -0.79'(8,591.29') -1.25'(8,590.84') -1.08'(8,591.00') PIP DPIP A PIP E PIP G PIP J PIP K PIP M PIP S PAD 04 PAD 02 PAD 07 PAD 08 PAD 11 PAD 10 PAD 12 PAD 13 PAD 14 PAD 15 PAD 09 PAD 06 PIP B PIP C PIP F PIP H PIP L PIP P PIP N PIP WA PIP WB PIP WC PIP Q PIP R PIP WD PIP WE PIP WF PIP WG PIP WH PIP WM PIP WN PIP WQ PIP WP PIP WR DOWN DOWN 2 A5.03 2 A5.03 1 A5.02 1 A5.02 A C D E 6 B 2 PIP Foundation Schedule Element ID PIP A PIP B PIP C PIP D PIP E PIP F PIP G PIP H Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 4'-0" 3'-11/2" 3'-0" 2'-0" 2'-2" 2'-0" 2'-6" 3'-6" BOF to Sea Level 8,586.50' 8,587.37' 8,588.37' 8,589.37' 8,589.21' 8,589.37' 8,588.87' 8,587.87' Length 12.96' 2.94' 2.00' 24.47' 8.73' 2.70' 2.00' 14.02' PIP Foundation Schedule Element ID PIP J PIP K PIP L PIP M PIP N PIP P PIP Q PIP R Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 2'-6" 2'-6" 3'-0" 3'-0" 3'-6" 2'-71/2" 3'-0" 4'-0" BOF to Sea Level 8,588.87' 8,588.87' 8,588.37' 8,588.37' 8,587.87' 8,587.87' 8,587.50' 8,586.50' Length 19.50' 29.00' 8.15' 66.69' 2.00' 9.33' 2.00' 2.57' PIP Foundation Schedule Element ID PIP S PIP WA PIP WB PIP WC PIP WD PIP WE PIP WF PIP WG Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 4'-0" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-0" BOF to Sea Level 8,586.50' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,587.75' Length 43.87' 12.69' 8.15' 9.96' 4.02' 10.10' 2.50' 19.79' PIP Foundation Schedule Element ID PIP WH PIP WJ PIP WK PIP WM PIP WN PIP WP PIP WQ PIP WR Width 2.00' 5.50' 5.50' 5.50' 2.00' 2.00' 2.00' 2.00' Depth 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" BOF to Sea Level 8,587.75' 8,587.75' 8,587.75' 8,587.75' 8,588.67' 8,588.67' 8,588.67' 8,588.67' Length 4.41' 33.49' 32.50' 11.49' 8.67' 10.69' 8.67' 6.69' Footing Pad Schedule Element ID PAD 02 PAD 04 PAD 06 PAD 07 PAD 08 PAD 09 PAD 10 PAD 11 PAD 12 PAD 12 PAD 13 PAD 14 PAD 15 BOF to Floor line -3' -3' -3' -3' -3' -3' -3' -3' -3' -3' -3' -3' -3' BOF to Sea Level 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' 8,589.08' Depth 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1'-3" 1'-3" Length (A) 2'-6" 2'-6" 2'-6" 3' 3' 3' 3' 3' 14' 14' 26'-6" 4' 4' Width (B) 2'-6" 2'-6" 2'-6" 3' 3' 3' 3' 3' 3' 3' 3' 4' 4' Steel (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 EW Bottom (4) #5 lengthwise, #5@3' oc Crosswise (4) #5 lengthwise, #5@3' oc Crosswise (5) #5 EW Bottom (5) #5 EW Bottom STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. NOTES: 1. POURED BUILDING WALL FOOTINGS TO HAVE (3) #5 BARS, BOTTOM. SEE RETAINING WALL SECTION DETAILS FOR REINFORCEMENT AT RETAINING WALLS. 2. SEE STEPPED FOOTING DETAIL FOR MORE INFORMATION. 3. SEE WALL SECTIONS, GEOTECH REPORT, AND CIVIL DRAWINGS FOR FOOTING DRAINAGE. 10/11/18 FIRST FLOOR MODULES A B C D E F G H SECOND FLOOR MODULES RevID ChID Change Name Date 9 10 12 27 Retaining Wall Foundation Revisions 8/22/18 9/6/18 10/2/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: S.02 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: Retaining Wall Footing plans Drawing: Retaining Wall Footing plans Scale: 1/4" = 1'-0", 1:1.33, 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 10/2/18Date printed: 12'-113/8" 2'-6" 2'-0" 21'-31/8" 12'-111/2"2'-113/8" 2'-0" 15'-4" 14'-21/8" 4'-71/8"2'-0" 41'-101/2" 2'-0"2'-67/8" 2'-0" 9'-4" 2'-0"6'-6"19'-91/2"4'-47/8" 2'-0"2 4 '- 6 "29'-73/8"27'-85/8" 14'-21/8" 2 3 '- 7 5 / 8 "27'-25/8"1'-0" 1'-0" 5'-0" 5'-0"1'-0"1'-0"67/8" 101/4"67/8"-0.79'(8,591.29') PIP A PIP S PIP B PIP P PIP NPIP Q PIP R PIP WH PIP WG PIP WJ PIP WK PIP WM DOWN 6 2 6 A4.20 61/8"15'-03/4" 7'-33/4"1'-0"-0'-4.5" TW: 8,594.00' TW: 8,594.00' TW: 8,595.00' TW: 8,594.91' TW: 8,592.92' TW: 8,592.92' TW: 8,592.92' 04 A3.04 1 A5.11 1 A5.11 A A4.01 5 A5.10 5 A5.10 BM-06 BM-04 BM-02 BM-07 BM-08 C02 C04 C06 FIELD CONNECTION BY STEEL FABRICATOR; INSTALLED BY LC LINE OF BUILDING ABOVE HEATED DRIVEWAY DOWN SPOUT DOWN SPOUT SLOPE; 1/4"/FT.2 x 10 @12" O.C. 2 x 10 @12" O.C. 2 x 10 @12"O.C. 2 x 10 @12" O.C.(2) 2 x 12 HEADER(2) 2 x 12 HEADER (2) 2 x 12 HEADER FLAT 63/4" 22'-41/2"43/4"VERIFY ALL TOP OF WALL CALLOUTS WITH CIVIL PLANS VERIFY ALL TOP OF WALL CALLOUTS WITH CIVIL PLANS UP 3R HOSE BIB PIP Foundation Schedule Element ID PIP A PIP B PIP C PIP D PIP E PIP F PIP G PIP H Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 4'-0" 3'-11/2" 3'-0" 2'-0" 2'-2" 2'-0" 2'-6" 3'-6" BOF to Sea Level 8,586.50' 8,587.37' 8,588.37' 8,589.37' 8,589.21' 8,589.37' 8,588.87' 8,587.87' Length 12.96' 2.94' 2.00' 24.47' 8.73' 2.70' 2.00' 14.02' PIP Foundation Schedule Element ID PIP J PIP K PIP L PIP M PIP N PIP P PIP Q PIP R Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 2'-6" 2'-6" 3'-0" 3'-0" 3'-6" 2'-71/2" 3'-0" 4'-0" BOF to Sea Level 8,588.87' 8,588.87' 8,588.37' 8,588.37' 8,587.87' 8,587.87' 8,587.50' 8,586.50' Length 19.50' 29.00' 8.15' 66.69' 2.00' 9.33' 2.00' 2.57' PIP Foundation Schedule Element ID PIP S PIP WA PIP WB PIP WC PIP WD PIP WE PIP WF PIP WG Width 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' 2.00' Depth 4'-0" 1'-4" 1'-4" 1'-4" 1'-4" 3'-6" 3'-6" 4'-4" BOF to Sea Level 8,586.50' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,587.87' 8,586.82' Length 43.87' 12.69' 8.15' 9.96' 4.02' 2.50' 10.10' 5.89' PIP Foundation Schedule Element ID PIP WH PIP WJ PIP WK PIP WM Width 2.00' 7.00' 7.00' 5.50' Depth 4'-4" 1'-0" 1'-0" 1'-0" BOF to Sea Level 8,586.82' 8,587.75' 8,587.75' 8,587.75' Length 19.79' 38.65' 29.06' 9.59' STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 12.27 12.27 12.27 SCALE: 1/4" = 1'-0" 1 Footing plan S.02 SCALE: 1/4" = 1'-0" 2 BSMT/Garden Level S.02 NOTES: 1. POURED BUILDING WALL FOOTINGS TO HAVE (3) #5 BARS, BOTTOM. SEE RETAINING WALL SECTION DETAILS FOR REINFORCEMENT AT RETAINING WALLS. 2. SEE STEPPED FOOTING DETAIL FOR MORE INFORMATION. 3. SEE WALL SECTIONS, GEOTECH REPORT, AND CIVIL DRAWINGS FOR FOOTING DRAINAGE. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: S.03 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: BSMT/Garden Level Framing Drawing: BSMT/Garden Level Framing Scale: 1/4" = 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions:6/26/18 Date printed: Steel Beam Schedule Home Story BSMT/Garden Level Element ID BM-02 BM-04 BM-06 BM-07 BM-08 BM-11 BM-12 BM-13 BM-14 Bm Bearing to Floor Line 6'-11 1/2" 6'-11 1/2" 6'-11 1/2" 6'-9 1/4" 6'-9 1/4" 7'-9 1/2" 7'-9 1/4" 7'-9" 7'-6" Beam Length 15'-6 3/4" 15'-7" 15'-6 3/4" 20'-9 3/4" 23'-1 1/2" 16'-5 1/4" 13'-2 1/2" 37'-2 1/2" 18'-5" W-Shapes W8x18 W8x18 W8x18 W10x26 W10x26 W10x49 W10x26 W10x77 W12x30 Depth 0'-8 1/4" 0'-8 1/4" 0'-8 1/4" 0'-10 1/4" 0'-10 1/4" 0'-10" 0'-10 1/4" 0'-10 1/2" 1'-1/4" Weight/ft 18.00 18.00 18.00 26.00 26.00 49.00 26.00 77.00 30.00 N0 2'4' 8' 3 A5.50 61/8"15'-03/4" 7'-33/4" 5'-2" 43/4" 5'-111/4" 43/4" 81/2"4'-43/8"63/4" 5'-83/8"1'-07/8"107/8"10'-101/2"43/4"2'-0"43/4"3'-0"43/4"2'-1"2'-21/8" 1'-6" 4'-3" 1'-6" 4'-3" 1'-6" 1'-71/2" 3'-61/2" 43/4" 8'-01/8" 3'-43/4"63/4" 3'-35/8"43/4" 2'-0" 107/8" 3/4" 2'-91/2" 3'-111/2" 4'-61/4" 15'-21/8"10'-8" 63/4" 15'-53/4"11/2"1'-0"0.00'(8,592.08') -0'-4.5" (8591.71') -1'-3" (8590.83') TW: 8,594.00' TW: 8,594.00' TW: 8,592.92' TW: 8,592.92' TW: 8,592.92' TW: 8594.87 TW: 8594.87 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01CA4.015 A5.10 5 A5.10 1 2 3 4 A4.18 1 2 3 4 A4.18 6 7 8 9 A4.19 5 6 A4.20 2A4.18 POURED IN PLACE REINFORCED CONCRETE STAIR AND RETAINING WALLS WITH #5 @ 16" EW. SEE SPECIFICATIONS AND FINISH SCHEDULES. BM-06 BM-04 BM-13 BM-11 BM-13 SEE MC SHOP DRAWINGS FOR FRAMING IN THIS AREA BM-02 BM-07 BM-08LATERAL BRACING METHOD GB LATERAL BRACING METHOD WSP: 7/16" OSB SHEATHING EACH SIDE. LATERAL BRACING METHOD GB BM-12 BM-14 C02 C04 C06 C12 C10 C15 C16 C17 C19 C19 C14 C08 C07 C09 C11 FIELD CONNECTION BY STEEL FABRICATOR; INSTALLED BY LC LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE HEATED DRIVEWAY DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT DOWN SPOUT HEATED SIDEWALK ENTRY SECONDARY UNIT ENTRY MAIN HOUSE ELEVATOR TANK & CONTROL SLOPE; 1/4"/FT. ROOF DRAINAGE 2 x 10 @12" O.C. 2 x 10 @12" O.C. 2 x 10 @12"O.C. 2 x 10 @12" O.C.2 x 10 @ 12 O.C. 2 x 10 @ 12 O.C. 2 x 10 @ 12 O.C.SOFFITBEAM ABV DROPPED CLGBEAM ABOVE DROPPED CEILING BEAM ABV DROPPED CLGBEAM ABV DROPPED CLG 2 x 6 @12 O.C.2 x 6 @12 O.C.(2) 2 x 12 HEADER(2) 2 x 12 HEADER (2) 2 x 12 HEADER PEX MANIFOLDSROUGH OPENPROPOSED METERLOCATIONSPROVIDE SIMPSON HDQ8-SDS3 HEAVY DUTY HOLDOWNS TOP AND BOTTOM FOR ALLSHEAR WALLS (METHODS GB AND WSP). MAX 16' O.C, MIN (2) PAIR PER WALL IN-GROUND HOT TUB HEATED PATIO FLAT 1A5.0102 A3.02 05 A3.05 6 A3.06 63/4" 22'-41/2"43/4"2'-05/8"31/2"3'-05/8"43/4"2'-1"4'-3" 43/4"6'-23/8"43/4"1'-4" 4'-61/4"101/4"10'-8" 63/4"15'-53/4" 63/4" 4'-0" 6 3/4"11'-1"1 A4.20 C13 VERIFY ALL TOP OF WALL CALLOUTS WITH CIVIL PLANS VERIFY ALL TOP OF WALL CALLOUTS WITH CIVIL PLANS UP 16R UP 7R DN 4R UP 3R NICHE NICHE HOSE BIB HOSE BIB HOSE BIB HOSE BIB SCUPPER ABOVEUP 2RFLOOR DRAIN STAIR INFO TREADS : 11-1/4" RISERS : 7-1/4" Columns Schedule Home Story BSMT/Garden Level First Floor Second Floor Element ID C02 C04 C06 C07 C08 C09 C10 C11 C12 C13 C14 C15 C16 C17 C19 C19 C11 C11 C11 C11 C11 C11 Bearing to Floor Line -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -2'-0" -1'-3" -1'-3" -1'-3" -1'-3" -1'-3" -1'-3" Core Dimension 1 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-4" 0'-5" 0'-4" 0'-4" 0'-5" 0'-5" 0'-5" Height 8'-9 1/4" 8'-9 1/4" 8'-91/4" 10'-71/2" 9'-91/8" 9'-91/8" 9'-111/8" 9'-111/8" 9'-31/8" 9'-2" 10'-91/2" 10'-91/2" 10'-91/2" 10'-91/2" 9'-8 7/8 " 9'-87/8" 9'-91/2" 9'-91/2" 9'-91/2" 9'-91/2" 8'-107/8" 8'-107/8" Steel 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge Standard Structural Steel, (10.6 plf) 5/8" cap & Br PL, w (4) 5/8" bolts, each PL Standard Structural Steel, (10.6 plf) 5/8" cap & Br PL, w (4) 5/8" bolts, each PL 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge 11 Gauge STRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 10/11/18 FIRST FLOOR MODULES 1 2 3 4 5 6 7 8 SECOND FLOOR MODULES RevID ChID Change Name Date 5 04 Balcony Change 6/14/18 evoDOMUS LLC 3143 W 33rd Street Cleveland, OH 44109 Phone : (216) 772-2603 Sheet Size: 24" x 36" Sheet Number: S.04 Phase: Original issue Date of Permit Set:Project Number:STMProject Name:Sturm ResidenceClient: First Floor Framing at Decks Drawing: First Floor Framing at Decks Scale: 1/4" = 1'-0", 1/2" = 1'-0" CONSTRUCTION DOCUMENTS 08-25-2017 Paul and Leisa Sturm 5044 Main Gore Drive S Vail, Colorado 81657 Developer: Lot 2 Vail Meadows Filing No. 1 RWS Architectural Consulting, LLC 1361 Lakeland Ave. Lakewood, OH 44107 Phone: (216) 401-3830 rwshearer@gmail.com Robert W. Shearer, RAColorado Registered Architectnumber:ARC.00404908License Expires 10-31-2019Architect: Revisions: 6/25/18Date printed: 03 A3.01 01 A3.01 04 A3.04 1 A5.11 1 A5.11 59 #LayID 59 #LayID A A4.01 BA4.01CA4.015 A5.10 5 A5.10 C1 C1 13'-113/8" 13'-113/8" 15'-101/4" 15'-2 3/4" 2'-8" 5'-2" 27'-67/8" 5'-31/8" 9'-23/4"1'-11/4" 1'-43/4" 2'-21/2" 3'-43/8" 2" 2" 8'-4" 2" 12'-55/8" 61/8" 6'-45/8" 61/8" 2'-111/2" 43/4" 4'-11/2" 4'-3" 7'-111/8"5/8"18'-71/2" 3'-11" 4'-03/4"6'-01/4" 41/8" 1'-2" 61/8"4'-91/4" 1'-11" EQ EQ 3'-33/4" 101/4"2'-23/4" 3'-11/2"EQ EQ8'-33/8"3'-11/2" 3'-41/2" 4'-61/4" 1'-113/4" 5'-67/8" 7'-31/2" 2'-11/4" 10'-1" 2'-6" 12'-01/2" 1'-11/4" 2'-3" 1'-01/8" 9"6'-3" 2'-0"3'-55/8" 2'-93/8"4'-61/2"81/2"2'-0" 8'-51/4"3'-91/4" 12'-21/2"1'-101/4"1'-10" 8'-5"63/4"8'-03/8"3/4" 2'-91/2" 3'-111/2"W x 7'-5 3/4" H RO (From subfloor) 8'-8" 5'-111/4"1'-4" 2'-4"4'-01/4" 18'-41/4"8'-11 1/2" 4 3 2 A4.12 5 6A4.12 1 2 3 4 A4.15 1 2 3 4 A4.14 7 8 9 10 A4.15 2 1 3 4 A4.10 1 2 3 4 A4.11 7 6 5 8 A4.10 4 1 2 3 A4.16 1 2 3 4 A4.14 LC TO PROVIDE BALCONY STRUCTURE (UNSHADED AREA) (2) 2x10 PT END BEAM & JOIST HANGERS; INSTALLED ON SITE Simpson Strong-Tie® HU210 JOIST HANGER - INVERTED; TYP. OF CANTILEVERED DECK JOIST Simpson Strong-Tie® HUCQ-210-2 JOIST HANGER Simpson Strong-Tie® HUC-210-2 JOIST HANGER Simpson Strong-Tie® HUC-210-2 JOIST HANGER Simpson Strong-Tie® HUC-210-2 JOIST HANGER SCREW (2) PT 2x10's INTO SIDE WALLS WITH INDICATED SCREW PATTERN ON SHT. A5.07 LC TO PROVIDE BALCONY STRUCTURE DRYWALL SHAFT - 3 SIDES; 3/4" PLYWOOD on RAIL SIDE 2x10's @ 16 o.c.PT 2x6's @ 16 o.c.(2) PT 2x10's(2) PT 2x12'sDBL STUD WALL 2x4 & 2x6 TO MARRIAGE WALL STUD (2) PT 2x10's (2) PT 2x10's (2) PT 2x10's (2) PT 2x10's - 10' LONGPT 2x6's @ 16 o.c. (2) PT 2x12's (2) PT 2x12's 02 A3.02 05 A3.05 6 A3.06 A C D E 6 6 1 5 3 B 2 2 4 6'-4"43/4"5'-73/4"1'-0"9'-5"41/8"77/8"3'-11"5'-0" 43/4"5'-10" 2'-0"43/4"8'-01/4"63/4"4'-73/4"12'-21/4"41/8" 14'-05/8" 8'-33/4"43/4" 3'-6" 2'-0"9'-103/8" 11'-71/2"8'-4"#DrgID 5 6 #LayID MC TO PROVIDE DECK JOISTS IN MODULES (SHADED AREA) GALVANIZED HSS 5x5x3/8 STEEL POST; INSTALLED AT FACTORY (TYP. OF 2 @ LIVING ROOM) GALVANIZED C 6x8.2 C CHANNEL; CONNECT TO GALV. STEEL POST (TYP. OF 4) GALVANIZED HSS 4x4x5/16 STEEL POST; INSTALLED AT FACTORY (TYP. OF 2 @ KITCHEN)2x6 PT LEDGER BOARD; ATTACH W/2-1/4" SDS SCREWS @ EA. WALL STUDPT 2x10's @ 16 o.c.(2) PT 2x10'sSTRUCTURAL NOTES: 1. Design and detailing of Superior Wall foundation wall system is delegated to Colorado PE employed by Superior Wall. Colorado PE to be responsible for all design requirements and details of Superior Wall products. Superior Wall to submit to local building official full set of plans and calculations for this project and signed by PE responsible for the design. 5.04 5.04 10/11/18