HomeMy WebLinkAboutB18-0283 Letter of Record.pdf• lutions .i nc "'"' ENGINEERING
01.24.19
Town of Vail Building Department
Project/Job Number:
Letter of Record
Shapiro Residence Addition (4425 Glenn Falls Lane) Job # 0206-18
PO BOX 2494
AVON, CO 81620
PH. 970.949.7100
FAX. 970.949.3377
This "Letter of Record" is in regards to the steel to steel connections for the above referenced project.
The office of Structural Design Solutions, Inc. feels that all the bolted connections that are indicated on
the revised set of structural plans dated 01-23-19 can be welded together with full length 3/16" fillet,
grove or butt welds. All welding shall be done by an AWS certified welder. Field welds may require
special inspection in accordance to section 1704.3.1 of the 2018 IBC and local building officials. If there
are any questions or concerns please call me at (970)-949-7100.
Signed:
t-
Jeffrey P. Leonardo, P.E.
President