Loading...
HomeMy WebLinkAboutB05-0104TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 DEPARTMENT OF COMMUNITY DEVELOPMENT qck NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PROJECT TITLE: NEW (SFR,P/S,DUP) PERMIT Permit B05-0104 Job Address: 1807 ALPINE DR VAIL Status . ..: FINAL Location.....: 1807 ALPINE DR Applied ..: 05/17/2005 Parcel No...: 210312307014 Issued . .. 06/20/2005 Project No PRJ05-0005 Expires . .: 07/10/2007 OWNER RAIOLA, MILDRED J. C/O MJ RAIOLA 2448 GARMISCH AVE 11 VAIL CO 81657 APPLICANT RAIOLA,M. JAY 2448 GARMISCH #11 VAIL COLORADO 81657 License: 345-L CONTRACTOR RAIOLA,M. JAY 2448 GARMISCH #11 VAIL COLORADO 81657 License: 345-L Desciption: RAIOLA NEW SFR Occupancy Type Dwellings Zone 1 V-N Totals... Number of Dwelling Units: I 05/17/2005 Phone: 471-0618 05/17/2005 Phone: 477-1984 05/17/2005 Phone: 477-1984 Factor Sq Feet Valuation 81.50 4,112 $335,128.00 4,112 $500,000.00* Town of Vail Adjusted Valuation: $500,000.00 Fireplace Information: Restricted: Y # of Gas Appliances: 1 # of Gas Logs: 2 # of Wood Pallet: 0 *r*?t**************a******r*t******t**s*r*ts?**r**+********r**** FEE S UMMARY t**t*s*+****+*s**+*****,****rr***t***a**s*r*******rr+****** Building ----- -> $3,233.75 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $5,955.49 Plan Check ---> $2,101.94 Recreation Fee------------ > $616.80 Additional Fees ------------- > $0.00 Investigation-> $0.00 TOTAL FEES---- $5,955.49 Total Permit Fee------------ > $5,955.49 Will Call-----> $3.00 Payments -------------------- > $5,955.49 BALANCE DUE--------- > $0.00 **?*rs***??***?****r+«*t****«****r?**r******r?***s**r*?*t**?*********?**r**********a**??*****s**s?********:v.??***¦**a**s¦*rv*:**a*?s*:r**s?s*?r+*** Approvals: Item: 05100 BUILDING DEPARTMENT 06/08/2005 cgunion Action: CR comments in F:\cdev\CHRIS\PERMIT.COMMENTS\B05-0104.DOC 06/17/2005 cgunion Action: AP corrected plans approved. 03/17/2006 cdavis Action: AP As built structural plans appoved with eng: record letter Item: 05400 PLANNING DEPARTMENT 06/02/2005 ee Action: COND Item: 05600 FIRE DEPARTMENT 05/27/2005 mvaughan Action: AP Require stairs for access ott street side access and monitored fire alarm system Item: 05500 PUBLIC WORKS 06/20/2005 gc Action: COND Must have staging plan that is approved by NO road closuers. Item: 05550 ENGINEERING CIVILS See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER PAGE 2 CONDITIONS OF APPROVAL Permit #: B05-0104 as of 02-24-2009 Status: FINAL Permit Type: NEW (SFR,P/S,DUP) PERMIT Applicant: RAIOLA,M. JAY Job Address: 1807 ALPINE DR VAIL Applied: 05/17/2005 Issued: 06/20/2005 Location: 1807 ALPINE DR Parcel No: 210312307014 CONDITIONS Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Entry: 06/02/2005 By: ee Action: COND New foundation plan sheet approved on 060205 shall be stamped by an architect and engineer if required by the building department Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. 03/14/2006 16.28 FAX 7194868220 DALE I WIBBENM EYE R. P.O. Box 1005 Leadville, CO 80461 Date: March 14, 2006 To: Charlie Davis, Town of Vail Community Development Department From: Dale Wibbenmeyer, Engineer Re: Raiola Residence, 1807 Alpine Drive, Vail, Pen-nit #1305-0104 ?001/001 The following addresses item 10 of the Framing Inspection Report dated 3/1/06 and also the support for the 3-ply truss in the garage: 10) Furred wall in lower level is bearing wall. The 2" x 4" furred wall in the lower level is acceptable to support the floor framing for the master suite. b t t ? c ? 1 O to ?c tf I 446 C. 14 C'N $-I W yn, fir Provide (2) - 2" x 6" studs under each end of the 3-ply truss in the garage roof. nu. olol R J W (0 TU Izzs 6001 W: F * = ?nrk tic. + r7 E. • 6W ST "t 1. u,s/ 1 1/zwb 14.01 rnx r 1d4bbuzzv d4q DALE J. WIBBENMEYER P.O. Box 1005 Leadville, CO 80461 Date: March 11, 2006 To: Charlie Davis, Town of Vail Community Development Department From: Dale Wibbenmeyer, Engineer Re: Raiola Residence, 1807 Alpine Drive, Vail, Permit #B05-0104 10001/001 The following addresses items 2., 3., 9. and 10. of the Framing Inspection Report dated 3/1/06: 2. Roof framing in study, kitchen, dining not per plan. , The roof framing is adequate without the collar ties in the study and with the collar ties ?/ raised in the kitchen and dining room. 3) Ladder framing shown at 16" OC, as built is 24" OC. / The 2"x6" lookout ladder framing at 24" OC is adequate. zl 9) TJl's spect BCI's as built. T..h&ACI 450's are acceptable. ZZ 10) F ed wall in lower level is bearing wall- urred wall in the lower level is acceptable to support the floor framing for the master suite as shown in Section - A on Drawing 7 of 14. m ?i ;n 11-0 6 3 16 7//z/ S r)-? Cc C'Lt(F 'Z- ?-e Mar 03 06 03:40p Mildred Raiola 970-477-1984 p.2 TOV Framine Insnection Report 3/1/06 #BO5-0104 1) Truss shops do not reflect as built, loading on trusses is 40 psf, 3-ply girder truss not shown. . I/ New truss drawings on site. Will note change on plans. 2) Roof framing in study, kitchen, dining not per plan. Can I install collar ties above beam? 3) Ladder framing shown at 16" OC. as built`is 24" OC. Where? On roof overhangs?--- C U (S Jfl. f 4) In bedroom 4 add 2x6 to fully bear eeTbeam. How is 16 %a GL attached to column & steel beam in corner? L) C11 q Add 2x6 where along beam? 5) At stairs, 11 7/8 LVL spect, 9 % LVL as built & nowhed. Will note change on plans. 4-111? '•1 V4 *6) Check all sill plate anchor bolts, some not tight, add bolts as needed in lower level. Will do. -1)(,Iq C 7) I joists at Dbl LVL require hangers. Where? In hall outside MA BR? *8)13end &-nai1 tabs of hangers at 14".1.VT, MA RR. 'iV t. L. NCI Will do. 9) TJI's spect BCI's as built. --, L. 1,4 C;, / 4)1' 0t -?-9 Aren't these the same? If not, shall I just note change on plans? 10) Furred wall in lower level is bearing wall. ?. . t Can I add 2x4's to strengthen existing framing? `, i /z- c- 11) Deck at MA BR is not per plan. Will note change on plans. f L * 12) Grout column base. PCfi- Where? L C * 13) House is not dried in, roof leaking. Corrected. * 14) Deck framing requjms insnee iu *All items required to be addressed by engineer, except 6,8,12,13,14. a z ZO? - ?, q C,> (A ( -0 1,,- 4