Loading...
HomeMy WebLinkAboutCompliance CertificateCOMcheck Software Version 4.0.6.2 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Construction Site: 598 Vail Valley Drive Vail, CO Owner/Agent:Designer/Contractor: Architectural Engineering Design Group, Inc. 1900 Wazee Street, Suite #350 Denver, CO 80202 Project Information Energy Code: Ski and Snowboard Club - Vail High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-School/University 38862 0.87 33810 33810Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-School/University LED 1: C1: 24' LED Cove: Other:1 2 400 800 LED 2: C2: 36' LED Cove: Other:1 2 601 1202 LED 3: C3: 6' LED Cove: Other:1 8 50 400 LED 4: D1/EM: LED Downlight: Other:1 125 26 3250 LED 5: D2: LED Wallwash: Other:1 10 26 260 Linear Fluorescent 1: F1/EM: 4' Strip: 48" T8 32W: Electronic:2 50 70 3500 Linear Fluorescent 2: P3: 4' Fluorescent Pendant: 48" T8 32W: Electronic:2 13 70 910 Linear Fluorescent 3: P4/EM: 8' Fluorescent Pendant: 48" T8 32W: Electronic:4 2 140 280 Linear Fluorescent 4: P5/EM: 12' Fluorescent Pendant: 48" T8 32W: Electronic:8 12 320 3840 Linear Fluorescent 5: P6: 12' Decorative Pendant: 48" T8 32W: Electronic:8 1 320 320 LED 6: P7/EM: Parking Garage Fixture: Other:1 6 130 780 LED 7: P8EM: LED Cylinder: Other:1 2 18 37 Linear Fluorescent 6: R1/EM: 2x4 Troffer: 48" T8 32W: Electronic:3 22 105 2310 Linear Fluorescent 7: R2: 2x2 Troffer: 24" T8 17W: Electronic:2 11 35 385 Linear Fluorescent 8: R3/EM: 2x4 Troffer: 48" T8 32W: Electronic:3 2 105 210 Linear Fluorescent 9: S1/EM: 2x4 Surface Mount: 48" T8 32W: Electronic:3 24 105 2520 Linear Fluorescent 10: S2: 4' Wrap: 48" T8 32W: Electronic:2 36 70 2520 LED 8: S3/EM: Parking Garage Fixture: Other:1 3 130 390 LED 9: S4: Surface Mount Light: Other:1 9 24 216 Linear Fluorescent 11: S5/EM: 8' Wrap: 48" T8 32W: Electronic:4 29 140 4060 Track lighting 1: T1: Track 8': Wattage based on 14 feet of track 0 0 420 420 Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 81 ofPage 09-15-17 E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Linear Fluorescent 12: W1EM: 4' Wall Mount: 48" T8 32W: Electronic:2 12 70 840 Linear Fluorescent 13: W2: 4' Vanity Fixture: 48" T8 32W: Electronic:1 2 35 70 Linear Fluorescent 14: W3: 12' Vanity Fixture: 48" T8 32W: Electronic:3 2 105 210 Linear Fluorescent 15: W4EM: 16' Wall Mount: 48" T8 32W: Electronic:4 2 140 280 Linear Fluorescent 16: W5: 2' Vanity Fixture: 24" T8 17W: Electronic:1 9 17 153 Linear Fluorescent 17: W6EM: 2' Wall Mount: 24" T8 17W: Electronic:2 1 35 35 30198Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 11% better than code Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 82 ofPage 09-15-17 Jeff Mullikin 09-15-17 COMcheck Software Version 4.0.6.2 Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Construction Site: 598 Vail Valley Drive Vail, CO Owner/Agent:Designer/Contractor: Architectural Engineering Design Group, Inc. 1900 Wazee Street, Suite #350 Denver, CO 80202 Project Information Energy Code: Ski and Snowboard Club - Vail 2 (Residential mixed use area)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Other door (not main entry)54 ft of door 20 Yes 1080 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 1080 1080 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Other door (not main entry) (54 ft of door width): Tradable Wattage LED 1: EG1: Monument Sign: Other:1 2 2 5 LED 2: EG2: In-Grade Building Light: Other:1 2 14 28 LED 3: EST1: Step Light: Other:1 59 6 354 LED 4: EW1/EM: Wall Sconce: Other:1 15 19 285 LED 5: EW3: Wall Sconce: Other:1 7 3 21 693Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 59% better than code Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 83 ofPage 09-15-17 Jeff Mullikin 09-15-17 Inspection Checklist Requirements: 52.0% were addressed directly in the COMcheck software COMcheck Software Version 4.0.6.2 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 84 ofPage 09-15-17 Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable C405.2.5 [EL25]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 85 ofPage 09-15-17 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 86 ofPage 09-15-17 Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.5.1 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 87 ofPage 09-15-17 Project Title: Data filename: Ski and Snowboard Club - Vail J:\2847.00 - Ski and Snowboard Club, Vail\Ltg Calcs\284700LC01 - IECC 2015.cck 09/14/17Report date: 88 ofPage 09-15-17