Loading...
HomeMy WebLinkAboutDRB18-0577_approved plans_1548280447.pdfFINAL SUBMITTAL 2018 NOVEMBER 26 DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM FIXTURE TYPE SYMBOL FIXTURE DESCRIPTION MANUFACTURER / ORDERING CODE FULL CUTOFF? ELEVATION LUMENS / FIXTURE FIXTURE COUNT FS1 Stake Mounted LED Pathway Light WAC Landscape Lighting 6091-27-BZ-MOD(18") / 9000- SP9-BZ YES 18" 37.2 EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS) FS2 Recessed LED Step Light Interlux (Linealight) E92559-W-05 YES 18" 135 EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS) FS3 Ingrade LED Marker Light Bega 88 673-K3 YES Ingrade, < 1" 67 EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS) FS5 Wall-Recessed LED Steplight Sistemalux S.6060W-UNV-FINISH YES 18" 30 EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS) FS6 Wall-Mounted LED Exterior Sconce Modern Forms WS-W28514-FINISH YES 72" 455 1 FS7 Ingrade LED Sparkle Light Design Plan CB1212-5-D-AI FULL CUTOFF UNDER OVERHANG Ingrade, 0" 88 EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS) FS8 Surface mounted LED RGBW Image Projector Rosco 2970000RGBW1 YES 28'-0" 1500 ALL ON 5 FS9 Wall-Mounted Gas Powered Torch Tempest Torch 72" N/A EXEMPT (GAS POWERED) FS11 Surface Mounted Linear LED Tape Light in and Architectural Build-Out Kelvix Lighting Tape: DK3K0WR-24V Extrusion: CH-607-2-FR-CP-EC YES 18" 390/FT EXEMPT (BELOW 18" ABOVE GRADE & MAX 400 LUMENS FS12 Handrail mounted LED Pathway light Alphabet 750-3-1-1-1 YES 36" 111 3 FS13 Recessed LED Adjustable Downlight USAI Lighting SR21W-BL-16WG1-3022KH-30- M-FINISH / SV-16WG1-IC-UNV- D6B-AL40 YES Roof Level 925 19 28 EXTERIOR FIXTURE SCHEDULE & OUTDOOR LIGHTING CODE COMPLIANCE TOTAL FIXTURE COUNT DRB APPROVED 12/19/2018 12:00:00 AM 8080806 0 807080608050 80 8 0 8090 8090 bw:67.0tw:68.569.4869.4570.4571.6372.7173.8860.04% 6% 6% 2% 2% 4% 4% 2% 81.41 76.5 81 77 81 78.38 76.76 75.14 73.5 74 72 73.5 60 7071.5 69 72.068 61.5 76.08 69.6469.75 73.38 3% 3%73.7274.0 73.5 73.5 76.23 T.W. 6667.7367.2367.47 67.68 67.66 68.1 67.9 67.5 70 75.5 73 71.5 70.5 70.5 70 72 74.5 81.5 71.5 77 80 74 74.5 75.5 78.5 79 82 74.5 75 78 80.5 83 68 82 80.5 76 79 76.3 T.W. 66 T.W. 66 T.W. 66 79.5 79 77.5 77.5 80.5 75.24 80.17 79.17 79.22 78.2 78.33 76.83 76.74 78.5 71.58 68.5 65.12 67.5 65.48 65.8464.95 73.25 73.36 75 79 79.84 73.5 80.0 76.22 72 78 79.8 74.0T.W. 70.0 T.W. 80.0 T.W. 66 74.0PADDLE COURT 60.0 GREEN ROOF 69.5 C C C C C C C C C C C C C A A SR SR SR SR SR SR SR SR SR SR SR A LP LP LP LP S S LP LP LP LP A A SR A LP S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S 67 68 69 70 71 72 73 74 75 75 69 68 67 66 65 68 69 70 71 64 63 62 68 69 70 70 74 80 79 78 67 66 72 82 84 86 88 90 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 78 87 69 68 70 71 70 75 65 88 83 85 87 89 81 82 89 90 79 79 80 7975 75 76 80 82 81 81 76 7 91 92 93 94 91 92 93 94 65 11 2 2 33 44 55 66 77 88 99 A A B B C C D D E E F F G G I I EXISTING BUILDING ENVELOPE PROPOSED BUILDING ENVELOPE PROPOSED RECREATION ENVELOPE EXISTING PRIVATE DRIVE PROPOSED ELECTRICAL METER CABINET PROPOSED GAS METER LOCATION EXISTING WATER MAIN & VALVES SKIWAY EASEMENT EXISTING FIRE HYDRANT SEWER MAN HOLE BEYOND SITE BOUNDARY WATER LINE IN UTILITY EASEMENT UTILITY EASEMENT SKIWAY EASEMENT SKI-IN STAIRS 3' - 8 7/ 8" 5' - 8"8' - 8"7' - 0"TRASH STORAGE IN GARAGE 15' - 0"15' - 0"15' - 0"15' - 0"15' - 0"SPA DINING PATIO LIVING PATIO PADEL BALL COURT ENTRY BRIDGE Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/8" = 1'-0"11/26/2018 11:12:59 AM A001 SITE PLAN1170WESTHAVEN TORRAS RESIDENCELJW 112618 1170 1/8" = 1'-0" 1 SITE PLAN No. Description Date DRB APPROVED 12/19/2018 12:00:00 AM UP UP UP UP UP UP UP BASEMENT DEDUCTION CALCULATIONS WALL # TOTAL AREA UNEXPOSED 1 177 0 2 196 27 3 734 442 4 349 266 5 46 24 6 164 37 7 184 30 8 281 209 9 250 250 10 56 56 11 202 118 12 97 20 13 98 20 14 154 27 15 599 498 16 49 49 17 94 94 18 111 0 19 135 0 20 66 0 21 139 139 22 92 92 23 209 209 24 22 9 4,504sf 2,616 (58%) BASEMENT FLOOR AREA: 6,489 SF 58% DEDUCTION: - 3,764 SF TOTAL BASEMENT GRFA: 2,725 SF A002 9 A002 3 A0028 A002 21 A002 A002 5 A002 20 A002 2 6 4 19 1 1 2 3 4 5 6 7 8 9 A B C D E F G H 8,061' - 6" A002 13 1214 A002 15 I 7 10 22 A002 11 A002 23 18 A002 17 A002 16 24 61.5 BEDROOMS 8,061' - 6" 74 ENTRY 8,074' - 0" AB C 61.5 BEDROOMS 8,061' - 6" 72 GAMES REC 8,072' - 0" 78 9 W1W2 W4 W5 61.5 BEDROOMS 8,061' - 6" 72 GAMES REC 8,072' - 0" CD E F G H W1 W2 W4W5W3 W2 W91 W2 61.5 BEDROOMS 8,061' - 6" 74 ENTRY 8,074' - 0" 6 7 8 9 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0"65 LEVEL 1 8,064' - 6" 76.5 LEVEL 2 8,076' - 6" H 61.5 BEDROOMS 8,061' - 6" 65 LEVEL 1 8,064' - 6" 76.5 LEVEL 2 8,076' - 6" 4 5 6 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" HI 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" 81 LIBRARY 8,081' - 0" 2 3 4 67 SKI ROOM 8,067' - 0" 81 LIBRARY 8,081' - 0" G H I 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" 1 2 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" F G 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" 1 2 67 SKI ROOM 8,067' - 0" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" E F 67 SKI ROOM 8,067' - 0" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" 1 2 67 SKI ROOM 8,067' - 0" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 81 LIBRARY 8,081' - 0" 83.5 MASTER 8,083' - 6" C D E 67 SKI ROOM 8,067' - 0" 76.5 LEVEL 2 8,076' - 6" 83.5 MASTER 8,083' - 6" 67 SKI ROOM 8,067' - 0" 72 GAMES REC 8,072' - 0" 76.5 LEVEL 2 8,076' - 6" 83.5 MASTER 8,083' - 6" 2 67 SKI ROOM 8,067' - 0" 72 GAMES REC 8,072' - 0" 76.5 LEVEL 2 8,076' - 6" 81 LIBRARY 8,081' - 0" BC 67 SKI ROOM 8,067' - 0" 83.5 MASTER 8,083' - 6" 2 3 67 SKI ROOM 8,067' - 0" 76.5 LEVEL 2 8,076' - 6" B C 67 SKI ROOM 8,067' - 0" 76.5 LEVEL 2 8,076' - 6" 34 5 61.5 BEDROOMS 8,061' - 6" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" A B 61.5 BEDROOMS 8,061' - 6" 74 ENTRY 8,074' - 0" 56 7 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0"65 LEVEL 1 8,064' - 6" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 9 Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATESAs indicated 11/26/2018 11:13:05 AM A002 BASEMENT CALCULATIONS1170WESTHAVENTORRAS RESIDENCELJW 112618 1170 BASEMENT GRFA PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No. Description Date 16 17 18 19 20 21 22 23 24 DRB APPROVED 12/19/2018 12:00:00 AM UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP UP 0808060 8070 80 8 0 8090bw:67.0tw:68.569.4869.4570.4571.6372.7173.8860.04% 6% 6% 2% 2% 4% 4% 2% 81.41 77 78.38 76.76 75.14 73.5 72 73.5 60 7071.5 69 68 76.08 69.6473.38 3% 3%73.7273.5 73.5 76.23 T.W. 6667.7367.2367.47 67.68 71.5 70.5 72 74.5 81.5 71.5 77 80 74 74.5 75.5 78.5 79 82 74.5 80.5 83 68 82 80.5 76 79 76.3 T.W. 66 T.W. 66 T.W. 66 75.24 80.17 79.17 79.22 78.2 78.33 76.83 76.74 78.5 71.58 68.5 65.12 67.5 65.48 65.84 64.95 73.25 73.36 75 79 79.84 80.0 76.22 72 78 79.8 T.W. 80.0 T.W. 66 PADDLE COURT 60.0 GREEN ROOF 69.5 C C C A A SR SR SR SR SR SR SR SR SR A LP LP LP LP S L LP A SR A S S S S S S S S S S S S S S S S S S S S S 67 68 69 70 71 72 73 74 75 75 69 68 67 66 65 68 69 70 64 63 62 68 69 70 70 74 80 79 78 67 66 82 84 86 88 90 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 8 78 87 69 70 71 70 75 65 88 83 85 87 89 81 82 89 90 79 79 80 7975 75 76 80 82 81 81 76 91 91 65 SITE COVERAGE: 20% OF 45,302 SF = 9,060SF ALLOWED 8,684 SF PROPOSED GRFA CALCULATIONS LOT AREA: 1.04 ACRES/ 45,302.4 SF ZONING: SPECIAL DEVELOPMENT DISTRICT SETBACKS: 20' FRONT, 15' SIDES, 15' REAR HEIGHT: 33' SLOPED, 30' FLAT LANDSCAPING: 27,181 SF REQUIRED PARKING: 6 SPACES TOTAL ALLOWABLE GRFA: 8,589 SF (NOT INCLUDED: 300 SF PER ENCLOSED GARAGE SPACE, BASEMENT DEDUCTIONS, CRAWL SPACES LESS THAN 5', VAULTED TALLER THAN 16' ) BASEMENT LEVEL: (6,489 before 58% deduction) 2,725 SF AFTER DEDUCTION MAIN LEVEL: 6,067 SF GARAGE SPACES: (-) 600 SF VAULTED SPACES: (127 +158) 285 SF TOTAL GRFA: (2,725 + 6,067 + 285 - 600) = 8,477SF * CURRENTLY UNDER BY 112 SF 1 2 3 4 5 6 7 8 9 G H Area 6,489 SF I 1 MECH. VAULT 8' - 3" 8' - 0" 7' - 6 1/8"8' - 3" 10' - 0"10' - 0"1 2 3 4 5 6 7 8 9 A B C D E F G H Area 6,067 SF I 1 A 158 sf VAULTED SPACE O/ 16' VAULTED SPACE O/ 16' 105 sf 1 1 22 33 44 55 66 77 88 99 A A B B C C D D E E F F G G I I4' - 0"8,093' - 1" 8,086' - 7" 8,089' - 7"8,085' - 7" 8,091' - 7" 8,095' - 7" 8,094' - 1" 8,098' - 1" 8,087' - 1" 8,684 SF SITE COVERAGE Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATESAs indicated 11/26/2018 11:13:48 AM A003 GRFA CALCULATIONS1170WESTHAVENTORRAS RESIDENCELJW 112618 1170 No. Description Date DRB APPROVED 12/19/2018 12:00:00 AM UP UP UP UP UP UP UP 11 22 33 44 55 66 77 88 99 A A B B C C D D E E F F G G H H 8,061' - 6" 10' - 0" 10' - 0" 26' - 0" 15' - 6" 8' - 0" 16' - 5 1/2" 10' - 3" 7' - 0" 13' - 0 1/8" 8' - 11 7/8" 10' - 0" 5' - 6" 14' - 6" 13' - 0" 7' - 0"CLOSET SKI IN/ SKI OUT CLOSETS SHOWER SHOWER CLOSETS I I SHOWER 10' - 0"CLOSETCLOSETBATH SHOWER SHOWER CLOSET10' - 0" 26' - 0" 15' - 6" 8' - 0" 16' - 5 1/2" 10' - 3" 10' - 0" 10' - 0" 10" 3 1/2" 8,061' - 5" 8,061' - 5"8,061' - 5" 8,061' - 6" 8,061' - 5" 8,063' - 0"2' - 6" 4' - 6"7' - 0" 13' - 0 1/8" 8' - 11 7/8" 10' - 0" 5' - 6" 14' - 6" 13' - 0" 7' - 0"14' - 4 7/8" 1' - 1 1/2" 19' - 1 1/2" 4' - 11 1/2" 6' - 6" 5 1/2" 8' - 11 1/2" 5 1/2" 3' - 6"1 A300 1 A301 3 A300 1 A302 2 A302 8,062' - 4"8,062' - 4" 8,067' - 0" PROPOSED BUILDING ENVELOPE PADEL BALL COURT W1 W2 W4 W5 W3 W2 W91 W2 W7 W10 W9 W13 W14 1 BOILER ROOM 35STORAGE 37 GUEST SUITE 4 39 GUEST SUITE 3 40 GUEST SUITE 2 41 BATH 2 42 BATH 3 43 GUEST SUITE 1 45 BATH 1 46 LINEN 49 MECHANICAL ROOM 50SPA EQUIPMENT 51 SKI POWDER 55 STORAGE 54 LAUNDRY ROOM 53 GYM 52 BUNK BATH 2B 57 PLAY AREA 60 W/D 125 W90 133 134 182 186 187 246 248 254 258 260 264 265 266 269 271 277 281 W6 W12W11 305 306 307 308 FULL BUNKS DRYGARDEN OPEN TO ABOVE W D W D SKI ROOM 62 SKI IN SKI OUT EXTERIOR STAIR, HEATED BUILT IN STORAGE FULL BUNKS QUEEN QUEEN BUILT IN STORAGE & BUNKS 6' - 6 5/8" 5 1/2" 8' - 7 1/2" 5 1/2" 6' - 6" 5 1/2" 8' - 11 1/2" 5 1/2" 6' - 0" 5 1/2" 9' - 6 1/2" 8' - 11 1/2" 5 1/2" 10" 8' - 11 1/2" 10" 5 1/2" 10' - 0 1/2" 5 1/2" 5' - 0 5/8" 5 1/2" 6' - 11 5/8" 5 1/2" 9' - 0 5/8" 7 1/4" 7' - 10 7/8" 5 1/2" 23' - 6" 5 1/2" 16' - 0" 4' - 1 7/8" 3 1/2" 10" 30' - 11 1/2" 15' - 6" 8' - 0"10"3 1/2" 10' - 0" 5 1/2" 9' - 5" 5 1/2" 5' - 9 3/8" 5' - 9 3/8"5 1/2" 6' - 0" 3' - 6 1/8" 10" 3 1/2" 7' - 2 1/8" 5 1/2" 22' - 8 5/8" 5 1/2" 2' - 11"10"3 1/2" 11' - 5 1/2" 3 1/2"6' - 6 1/4" 7 3/8" 7' - 1 5/8" 5 1/2" 10' - 11 1/4" 9"10" 3 1/2" 7' - 7 1/8" 5 1/2" 12' - 9 7/8" 10" 18' - 0 3/4" 7 1/4"5 1/2" 18' - 5 1/8" 5 1/2" 7' - 2 3/4"19' - 9"19' - 4 3/8"RAISED PLATFORM PRIVACY CURTAIN RAISED PLATFORM KING KING RAISED PLATFORM PRIVACY CURTAIN GYM 63 KING 15' - 8"7' - 0"14' - 10" MECH VAULT SHOWER 8,062' - 4" KING RAISED PLATFORM 8' - 8"WC 317 327 335 W15 339 340 341 342 7' - 11" 8' - 3"10' - 0"2' - 6"1' - 6"2' - 0"1' - 4" 8,064' - 5" 8,067' - 10" QUEEN QUEEN RAISED PLATFORM SHOWER SHOWER 8,067' - 0" BUNK BATH 1A 71 BUNK BATH 2A 72 BUNK BATH 2A 68 BUNK ROOM 2 69 BUNK ROOM 1 70 CHAPEL 74 8,064' - 6" 8,064' - 0" EGRESS WINDOW BATH 4 75 WC WC OPEN TO ABOVE LINE OF DECK ABOVE Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:13:50 AM A100 LOWER LEVEL PLAN1170WESTHAVENTORRAS RESIDENCEKKAA 112618 1170 1/4" = 1'-0" 1 65 LEVEL 1 No. Description Date DRB APPROVED 12/19/2018 12:00:00 AM UP UP UP UP UP UP UP UP 72 73 69 68 67 66 65 68 69 70 71 64 63 62 74 72 82 8484 83 82 81 80 78 69 68 70 71 70 75 83 81 82 79 79 80 7975 75 76 80 82 81 81 UP UP UP 11 22 33 44 55 66 77 88 99 A A B B C C D D E E F F G G H H 8,074' - 0" 8,076' - 6" 8,072' - 0" 8,073' - 0" 8,074' - 0" 8,081' - 0" 8,074' - 0" STORAGE TUB 10' - 0" 10' - 0" 26' - 0"15' - 6" 8' - 0" 7' - 0"13' - 0 1/8"8' - 11 7/8"10' - 0"5' - 6"14' - 6"13' - 0"7' - 0"7' - 10 7/8" 18' - 9 3/4" 26' - 9 1/2"7' - 7 1/2" 41' - 10 1/2" I I 16' - 5 1/2" 10' - 3"10' - 0"15' - 4 7/8"19' - 4 1/4"8,074' - 0" 8,082' - 0" 8,072' - 0" LIVING DECK DINING DECK MASTER DECK 8,081' - 0" 8,083' - 6" STAIRS 1 A300 1 A301 3 A300 1 A302 2 A302 W1 W4 W5 W22W23 W3W2 W91W2 W13 W14 W38 W26 W42 W19 W62 W81 W80 W76 W73 ELECTRICAL METER ENCLOSURE TRASH GARAGE 1 MUD ROOM 2 POWDER 3 THEATER 4 PANTRY 7 ENTRY 8 KITCHEN 9 GREAT ROOM 02 LINEN 11 IGNACIO'S NOOK COATS 17 DINING ROOM 18 CENTRAL STAIR 05 143 145 149 153 165 188 192 199 262 284 292 W40 W44 W25W21 W20 W28 W24 W27 W37W39 W45 W71 W72 W77 W78 W79 GUEST SUITE 4 06 SHWR 4 07 BATH 4 08 W.C. 4 09 CLOSET 4 10 Room 20 GUEST SUITE 5 19 CLOSET 5 21 BATH 5 22 WC 5 24 SHWR 5 23 CHAPEL 25 UPPER HALL 26 MASTER SUITE 32 MASTER STUDY 33 MASTER CLOSETS 34 . RAISED PLATFORM W87 W88 W85 W53 300 RANDOM LENGTH GLASS GUARDRAIL CAR CHARGER MECHANICAL VAULT W/D OPEN TO BELOW RANDOM LENGTH GLASS GUARDRAIL 1/2 ROUND TIMBER COLUMNS KING KING KING RAISED PLATFORM MASTER BATH 64 WCSHOWER TUB OPEN FACE GAS LOG SET FP W30 W29 311 W41 W43 W64 318 319 320 321 323 7 1/4" 25' - 4 3/4" 5 1/2" 8' - 8" 5 1/2" 5' - 7 1/4" 7 1/4"7' - 8 1/2"7 1/4" 25' - 6" 7 1/4" 4' - 1" 15' - 11" 7 1/4" 25' - 4 3/4" 15' - 6" 8' - 0" 5 1/2" 4' - 7 5/8" 5 1/2" 10' - 3 7/8"1' - 10 3/4"22' - 11 1/2" 5 1/2" 8' - 1 1/2" 5 1/2"9' - 11 1/8" 5 1/2" 5' - 1 3/8" 5 1/2" 12' - 9" 5 1/2" 10' - 0" 2' - 4 1/4" 33' - 7 3/4" 15' - 0 1/2" 5 1/2" 8' - 0" 5 1/2" 4' - 6 3/8" 5 1/2" 5' - 5 3/4" 5 1/2" 4' - 7 3/8" 5 1/2" 5' - 8 1/4" 5 1/2" 6' - 0" 5 1/2" 7' - 0" 7 1/4" 10' - 0" 7 1/4" 10' - 0 3/8" 3' - 6" 7' - 6 5/8" 3 1/2" 8' - 1 3/8" 5 1/2" 5' - 0 5/8" 3 1/2" 5' - 0" 7 1/4" 8' - 0" 7 1/4" 15' - 4 3/4" 5 1/2" 19' - 7 1/4" 7 1/4"7' - 0"13' - 0" 20' - 0" 18' - 11 7/8" 9 3/8" 18' - 7" 7 1/4" 7 1/4"8' - 11 3/8" 5 1/2" 2' - 11 7/8" 20' - 0" 4' - 5 1/8" 5 1/2" 14' - 1 1/4" 9 3/8" 4' - 0" 5 1/2" 3' - 11 3/4" 10' - 1 3/4" 7 1/4" 7 1/4"15' - 8 1/2"5' - 2 3/8"5 1/2"W63 W60 325 336 337 W70 W68 W51 W65 W54 W55 W61 2' - 6"7' - 11"7' - 11"6' - 5 1/8"5' - 6" 2' - 1" 14' - 0 1/8"7' - 8 1/2"OPEN TO BELOW Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:13:53 AM A101 UPPER FLOOR PLAN1170WESTHAVENTORRAS RESIDENCEKKAA 112618 1170 1/4" = 1'-0"1 76.5 LEVEL 2 No. Description Date DRB APPROVED 12/19/2018 12:00:00 AM UP UP UP UP UP UP UP UP UP 11 22 33 44 55 66 77 88 99 A A B B C C D D E E F F G H H I 1 A300 1 A301 3 A300 1 A302 2 A302 1 5/8" / 12" 1 1/1 6 " / 12 " 1 1/1 6 " / 12" 8,088' - 0 7/8" 8,094' - 1" 8,094' - 1" 8,094' - 1" 8,098' - 1" 8,098' - 1" 8,082' - 7" 8,086' - 7" 8,089' - 1" 8,087' - 1" 8,093' - 1" 8,095' - 7"8,091' - 7" 8,095' - 7"2 5/16" / 12"1 11/16" / 12"1 5/ 8 " / 12 " 1 5/ 8 " / 12 "1 7/8" / 12"1 7/8" / 12"1/4" / 12" 1 /4 " / 1 2" [No Slope][No Slope][No Sl o p e] ROOF DRAIN, TYP. 8,096' - 5 1/8"6 1/8"4' - 0"2' - 6"8,085' - 7" 8,089' - 7"4' - 0"8' - 3 1/2" 6' - 6 7/8"4' - 0"5' - 0"5' - 0"5' - 0 1/2"4' - 11 1/2"4' - 11" 4' - 11 1/2" 14' - 11"9' - 0"ALL ROOFS TO BE COVERED WITH NATIVE VEGETATION, TYP. INTERNAL ROOF DRAINS: FINAL LOCATIONS TBD Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:13:56 AM A110 ROOF PLAN1170WESTHAVENTORRAS RESIDENCEAuthor 112618 1170 No. Description Date DRB APPROVED 12/19/2018 12:00:00 AM 1 2 3 4 5 6 7 8 9 W62 W81 W80 EGRESS W76 W73 W72 W77W78 W79 W88 W87 30' HEIGHT LIMIT W66 W64 ELECTRICAL CABINET W65 TEXTURED STUCCO PANELS DARK GREY STEEL WINDOWS GREEN ROOFS, TYP. WOOD SOFFIT, TYP. STEEL PANEL CHIMNEY CAP 61.5 BEDROOMS 8,061' - 6" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 83.5 MASTER 8,083' - 6" AB C D E F G H ROOF PLAN 8,097' - 6" I W1 W2 W4W5 W22 W23 W3 W2 W91 W2 W38 W26 W19 EGRESS EGRESS EGRESS W7W6 W25 W21W20 W28 W27 W37 W39 W47W46 W48 W49 W50 W24 W34 W33 W32 W31 W12 W83W82 W84 W85 25' - 1"24' - 0"W29 W35 W36 W51 W11 PADEL COURT WITH GLASS AND MESH ENCLOSURE ASPEN LOG COLUMNS GLASS GUARDRAIL 3' - 0"67 SKI ROOM 8,067' - 0" 1 2 W13W14 W66 W90 W64 W15 W65 7 8 9 W19 HI W10 W9 W12 W11 Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:14:19 AM A200 EXTERIOR ELEVATIONS1170WESTHAVENTORRAS RESIDENCELJW 112618 1170 1/4" = 1'-0"1 EAST ELEVATION 1/4" = 1'-0" 2 NORTH ELEVATION No. Description Date EAST ELEVATION1 EAST ELEVATION2 NORTH ELEVATION1 DRB APPROVED 12/19/2018 12:00:00 AM 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" 81 LIBRARY 8,081' - 0" 83.5 MASTER 8,083' - 6" A B C D E F G H ROOF PLAN 8,097' - 6" I W62 W76 W73 W45 W71 W72 W77 W78 W79 17' - 1"26' - 1"14' - 7"W53 W56W57 W41 W64W63 W60 W58 W59 W70 W54 W55 W61 GREEN ROOFS, TYP. ASPEN LOG COLUMNS BASALT STONE AT SITE WALLS, TYP. WOOD SOFFIT 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" 83.5 MASTER 8,083' - 6" 1 2 3 4 5 6 7 8 9 ROOF PLAN 8,097' - 6" W42 W19 W62 W1W2 W4 W5 W22W23 W3W91 W2 W38 W26 W40 W44 W25 W21W20 W28 W24 W27 W37 W39 W45 29' - 7"26' - 7"28' - 1"30' HEIGHT LIMIT W53 W56 W57 W30W29 W41 W43 W58 W54 W55 TEXTURED STUCCO PANELS DARK GREY STEEL WINDOWS DARK GREY STEEL PANELING B/W WINDOWS 67 SKI ROOM 8,067' - 0" 65 LEVEL 1 8,064' - 6" G H W9 21' - 6"789 12 W13 W70W68 Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:14:38 AM A201 EXTERIOR ELEVATIONS1170WESTHAVENTORRAS RESIDENCELJW 112618 1170 1/4" = 1'-0"1 SOUTH ELEVATION 1/4" = 1'-0" 2 WEST ELEVATION No. Description Date SOUTH ELEVATION1 WEST ELEVATION 1 WEST ELEVATION 2 DRB APPROVED 12/19/2018 12:00:00 AM 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0" 65 LEVEL 1 8,064' - 6" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" 81 LIBRARY 8,081' - 0" 83.5 MASTER 8,083' - 6" 12 3 4 5 6 7 8 9 ROOF PLAN 8,097' - 6"8' - 9 3/8"7' - 11 3/8"12' - 3 3/8"7' - 11 7/8"10' - 9 3/8"125 165 188 266W91 W13 W87W88 W85 300 W70W68 61.5 BEDROOMS 8,061' - 6" 67 SKI ROOM 8,067' - 0" 65 LEVEL 1 8,064' - 6" BEARING 8,099' - 0" 72 GAMES REC 8,072' - 0" 74 ENTRY 8,074' - 0" 76.5 LEVEL 2 8,076' - 6" 81 LIBRARY 8,081' - 0" 83.5 MASTER 8,083' - 6" AB C D E F G H ROOF PLAN 8,097' - 6" I A400 1 W90133134 153 W13 W62 W80 W71 W78W79 W66 W53 300 W60 317 320 321 323 337 W70 W65 W54 W55 W61 W74W75 8,070' - 6" 8,067' - 0" Scale Date Drawn By Project Number © 2014 Kh Webb ArchitectsKENGO KUMA AND ASSOCIATES 1/4" = 1'-0"11/26/2018 11:14:53 AM A300 BUILDING SECTIONS1170WESTHAVENTORRAS RESIDENCELJW 112618 1170 1/4" = 1'-0"1 NORTH SOUTH CORE SECTION No. Description Date 1/4" = 1'-0" 3 EAST WEST SKI STAIR SECTION DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM DRB APPROVED 12/19/2018 12:00:00 AM