HomeMy WebLinkAboutDRB18-0604_Approved Plans_1546886281.pdfMATERIAL LEGEND
SECTION PLAN
CONCRETE
STONE
FRAME WALL
TILE
GLAZING
INSULATION
STEEL
GYP. WALL BOARD/
STUCCO / PLASTER
EARTH
GRAVEL / NON-
COMPACTED FILL
SAND
FINISHED
WOOD
ROUGH FRAMING
RIGID INSULATION
WOOD BLOCKING
PLYWOOD
SPRAY FOAM INSULATION
Room name
150 SF
A101
1 SIM
101
A101
1Ref
1 Ref1 Ref1Ref
A101
1Ref
1
Ref1
Ref1Ref
FD
GRID
LINE
?
LD
Name
Elevation
1
12
2
Room name
101
1
A101
SIM
3"
1i
/ 1 A101
1 View Name
1/8" = 1'-0"
1i
AREA TAG
DETAIL CALLOUT
CENTER LINE
INDICATOR
DOOR TAG
EXTERIOR
ELEVATION MARKER
INTERIOR
ELEVATION MARKER
FLOOR DRAIN
GRID LINE
MATERIAL INDICATOR
LANDSCAPE DRAIN
ELEVATION MARK
NORTH ARROW
REVISION MARK
ROOF SLOPE
ROOM TAG
SECTION MARK
SHOWER HEAD
SPOT ELEVATION
STEP
STRUCTURAL FRAMING
VIEW REFERENCE
VIEW TITLE
WINDOW MARK
SYMBOL LEGEND
NEPORENT RESIDENCE
184 BEAVER DAM RD. VAIL, CO. 81657
ZONE DISTRICT: TWO-FAMILY PRIMARY/SECONDARY RESIDENTIAL (PS)
LOT IS .477 ACRES, EQUAL TO 20,778 SF
ALLOWABLE GRFA
.46 SF/1 SF OF SITE AREA < 10,000 SF AREA OF THE SITE 10,000 X 0.46 EQUALS 4,600 SF
.38 SF PER 1 SF OF SITE AREA > 10,000 SF OF SITE AREA 5,000 X 0.38 EQUALS 1,900 SF
.13 SF PER 1 SF OR SITE AREA > 15,000 SF OF SITE AREA 5,778 X 0.13 EQUALS 751 SF
TOTAL ALLOWED GROSS RESIDENTIAL FLOOR AREA (GRFA) FOR ENTIRE LOT 7,251 SF
ALLOWED GRFA FOR PRIMARY UNIT 60% OF TOTAL GRFA (UNIT A) 4,351 SF
ALLOWED GRFA FOR SECONDARY UNIT 40% OF TOTAL GRFA (UNIT B) 2,900 SF
PROPOSED SQUARE FOOTAGE SUMMARY (BOTH SIDES OF DUPLEX COMBINED)
HABITABLE SF GRFA
LOWER LEVEL 3,186 SF 191 SF *1
MAIN LEVEL 4,163 SF 4,163 SF
UPPER LEVEL 2,708 SF 2,708 SF
GARAGE AREA OVER 600 SF 0 SF
TOTAL BOTH SIDES 10,057 SF 7,062 SF
TOTAL ALLOWABLE GRFA BOTH SIDES 7,251 SF
TOTAL REMAINING GRFA BOTH SIDES 189 SF
PROPOSED ADDITIONAL GRFA 25 SF
SITE COVERAGE
ALLOWABLE SITE COVERAGE ON THE LOT: 20% 4,156 SF
PROPOSED SITE COVERAGE BOTH SIDES - (FROM TOV RECORDS) 4,155 SF
PROPOSED SITE COVERAGE FOR ROOFS BEYOND 4' - SF
TOTAL REMAINING SITE COVERAGE BOTH SIDES 25.62 SF
PROPOSED ADDITIONAL SITE COVERAGE 25.0 SF
1* 94% OF THE LOWER LEVEL WALL IS ABOVE EXISTING OR FINISHED GRADE WHICHEVER IS MORE
RESTRICTIVE.
THEREFORE, 94% OF THE LOWER LEVEL SF IS COUNTED AS GRFA. LOWER LEVEL HABITABLE=
3,190 SF X 0.06= 191 SF
A. The contract documents, aka construction documents, consist of the architectural and structural drawings/notes, the exterior
color/material schedule, architectural finish schedule, and the project outline specifications as well as the agreement between the
contractor and owner. Any work shown, specified and/or noted in one of the documents shall be supplied as though fully covered in all.
Any discrepancy between the different parts should be reported to the architect immediately.
B. Contractor will assume responsibility of items requiring coordination and resolution during the construction process.
C. All work shall comply with all state and local codes and ordinances, and shall be performed to the highest standards of
craftsmanship by journeyman of the appropriate trades.
D. These documents are intended to include all labor, materials, equipment and services required to complete all work described
herein. It is the responsibility of the contractor to bring to the attention of the architect any conditions which will not permit construction
according to the intentions of these documents. It is the responsibility of the architect to provide details and/or directions regarding design
intent where it is altered by existing conditions or where neglected in the documents.
E. All change orders must be approved in writing by the owner prior to contractor performing any work associated with a change
order unless owner has authorized contractor to proceed.
F. Any materials proposed for substitution of those specified or called out by trade name in these documents shall be presented to
the architect for review and approval. The contractor shall submit samples, product data, manufacturers installation recommendations
and a side by side analysis / spread sheet comparing ASTM testing/performance or other applicable standards, warranty, limitations,
maintenance considerations, cost, lead time/schedule impact, any incompatibility/impact to other products or systems in project, and
impact on LEED certification if applicable for the project for the proposed substitution and the specified product. Once all required
information is received by architect, a minimum of three weeks is required for review and approval and or denial of substitution.
G. Submit samples as required by drawings and specifications. All samples shall be reviewed by the architect before the work is
performed. Work must conform to the reviewed samples. Any work which does not conform shall be removed and replaced with work
which conforms at the contractor's expense. Subcontractors shall submit requests and samples for review through the general contractor
when work is let through him or her. Required verifications and submittals to be made in adequate time as to not delay progress. Once
competed samples including all required product information if applicable is received by architect, a minimum of three weeks’ time is
required for review and approval and or denial of samples.
H. Shop drawings must be thoroughly reviewed and stamped approved by contractor prior to submitting to architect to make sure
they meet construction document requirements and are accurate in terms of correct quantities, dimensions, handing and design intent.
Shop drawings shall be submitted to the architect for his or her review where called for anywhere in these documents. Review shall be
made by the architect and architect’s consultants for general compliance with construction drawings and design intent only. Architect’s
review is required before work is begun, and work shall conform to the reviewed shop drawings, subject to replacement as required per
above. Architect will try to identify any discrepancies in shop drawings, but contractor is ultimately responsible for shop drawing accuracy
as the shop drawings are a product of their subcontractor.
I. The building inspector shall be notified by the contractor when there is need of inspection as required by the 2015 international
building code/international residential code, 2015 IECC, or any applicable or local code or ordinance.
J. The contractor shall be responsible for the safety and care of adjacent properties during construction, for compliance with federal
and state O.S.H.A. regulations, and for the protection of all work until it is delivered completed to the owner. Contractor to repair any
damage to adjacent properties or completed work at his or her own expense.
K. All dimensions noted take precedence over scaled dimensions. Dimensions noted with "N.T.S." denotes not to scale.
L. Contractor shall verify and coordinate all openings through floors, ceilings, and walls with all architectural, structural, mechanical,
plumbing, and electrical drawings. Verify with structural engineer if holes/notches can be cut in structural members prior to doing so.
M. Contractor to coordinate new construction w/ existing conditions and notify architect and structural engineer about discrepancies
of drawings of existing house/conditions and assumptions. Every reasonable effort should be made by contractor to protect and/or
minimize damage to existing conditions.
N. Contractor to coordinate sub-contractor start up meetings with the architect prior to the sub-contractor starting scope of work to
review the construction documents and to answer any questions.
The scope of work at 184 Beaver Dam Rd. Vail, CO 81657 shall consist of a remodel of an existing residence.
Main level interior changes:
Changes on this level will comprise a new larger chefs’ kitchen along with informal dining in place of existing
kitchen and dining area. A proposed addition will be made by moving a hall wall into the existing courtyard
space allowing for a new pantry area along with two storage closets on the main level. A new master suite will
replace existing guest room over the existing garage.
Upper level interior changes:
An existing master suite on the upper level will be replaced by two guest rooms with baths.
Exterior changes:
A new larger window will replace existing smaller window in the new master bath (master level north
elevation). A new proposed lift and slide door will be added at the courtyard off the kitchen. Proposing a new
out-swing patio door off lower hall into the courtyard. Proposing new sliding door and windows at kitchen (main
level south elevation). Proposing a new window at the second level new guest bath #1 (second level south
elevation).
A1.0 COVER SHEET
ARCHITECTURAL DRAWINGS
A3.2 MAIN LEVEL FLOOR PLAN
A3.3 UPPER LEVEL FLOOR PLAN
A3.4 ADDITION DIAGRAM MAIN LEVEL
A3.5 TRELLIS PLAN
A4.1 ELEVATIONS
A4.2 ELEVATIONS
A5.1 BUILDING SECTION
A5.2 BUILDING SECTION
EXISTING DRAWINGS
E3.1 EXISTING LOWER LEVEL PLAN
E3.2 EXISTING MAIN LEVEL PLAN
E3.3 EXISTING UPPER LEVEL PLAN
E4.1 EXISTING SOUTH ELEVATION
E4.2 EXISTING EAST ELEVATION
E4.3 EXISTING NORTH ELEVATION
Scale
Date
Drawn by
Checked by
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
PROJECT DIRECTORYABBREVIATIONS
DRAWING LIST:
VICINITY MAP
Galvanized
Laminated Wood Beam
General Contractor
Hardware
Gypsum Wallboard
Grade
Gypsum
RW
RO
SEW
SECT
SAN
SHLV
Cpt Carpet
CeramicCER
SIM
SHT
W/ Reinforce (d)REINFFD Floor Drain With (comb. form)
RequiredRound Head Sheet Metal ScrewGA FDN
FTG
RoomRM
RHSMREQDGaugeFoundation
Footing
WD
W/O
Wood
Without
and Air Conditioning
Heating, Ventilating,
LavatoryManufacturer
Laminate
Inside Diameter
Miscellaneous
Mechanical
Not In Contract
Medicine Cabinet
Masonry Opening
Horizontal
On Center
Not to Scale
Oriented Strand Board
Opposite
Outside Diameter
Property
Plywood
Perforated (d)
Prefinished Sheet Metal
Penny (nails, etc.)
Refrigerator
Radius or Riser
Not Applicable
AAD
ADD
AGG
ADJ
AOR
BM
ARCH
ALT
BD
BS
BET
BRG
AFF
CL
BLDG
CAB
CLOS CMU
CJ
CONC
COL
DP
DIA
DET
CONT
BO
DR
DN
DW
EL
EA
DRWG
DS
EQ
EJ
EXIST
EXT
FE CABT
FOC
FOS
FP
FL
FIN
DIM
GC
GALV
Glass
GLB
GRGL
HeadHD
HDW
GWB
Highway
Height
HWY
HT
HVAC
GYP
Addendum
Attic Access Door
Aggregate
AdjacentArea of Refuge
Alternate
Beam
Architectural
Board
Between
Both Sides
Bearing
Above Finished Floor
Interior
JointJT
INT
ID
MOMFGLAVLAM
Maximum
Material
MAX
MC
MTL
Minimum
NIC
MISC
MIN
MECH
Cabinet
Building
Centerline
Closet
Concrete
Column
Construction Joint
Detail
Diameter
DamproofingContinuous
Concrete Masonry Unit
HORBottom Of
OpeningOPG
OC
NTS
d
OD
OSB
OPP
PlatePL
PFSM
PLWD
PERF
Project
ProductPROD
PROP
PROJ
Drain
Dishwasher
Down
Elevation
Each
Drawing
Downspout
Equal
Existing
Exterior
Expansion Joint
Face Of Concrete
Face Of Stud
Fire Extinguisher Cabinet
ReferREF
REFRFloor
Fireproof RFinish
NADimension
Tounge and Groove
Toilet Paper Holder
Sound- Transmission Class
Vinyl Asbestos Tile
United States Gage
Unless Noted Otherwise
Uniform Building Code
SL
SQ
SPEC
STC
SM
SUB
STRUCT
STL
TV TEL SUSP SUPPL
IE
THK
TEMP
TO
T&B
T&G
TPH
STD
Roof Window
Sewer
Sanitary
Section
Rough Opening
Sliding
Shelves
Similar
Square
Specification
Sheet Metal
Sheet
Steel
Substitute
Structure (al)
TelevisionTelephoneSuspend (ed)Supplement (al)
That Is
Thick
Tempered
Top Of
Top and Bottom
Standard
UG
TYP
TS
USG
UBC
UNFIN
U.N.O.
VENT
VIF
VERT
VAR
VAT
WC
V
WT
WIN
WP
Typical
Underground
Tube Steel
Unfinished
Variable
Vertical
Ventilate
Verify In Field
Voltage
Water Closet
Weight
Window
Waterproof
T Tread
Issue Date:
Power Actuated FastenedPAF
Issue Date
CODE: 2015 IRC, CONSTRUCTION TYPE: V-B, R3
ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION
REQUIREMENT FROM CHAPTER 4 OF THE 2015 INTERNATIONAL ENERGY CODE PER ZONE 6B
ADOPTED BY THE TOWN OF VAIL, AND AS DEMONSTRATED BY PRESCRIPTIVE BUILDING THERMAL
ENVELOPE, AS FOLLOWS:
Maximum Glazing U-Factor of .32 for new single family dwelling units per Town of Vail amendments, this can
be a weighted average.
The proposed new windows and doors with dual glazed Low E glazing (Low E on two surfaces) exceeds this
requirement.
Building complies with the Energy Conservation requirement in Chapter 4 of the 2015 IECC per Zone 6B as
adopted by Town of Vail as follows:
The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IECC, as adopted by
Town of Vail, and an outline of the provided R values of the assemblies of the building which are defined in the
Construction Document Drawings and Specifications:
Existing Ceilings & Roofs Insulation - To remain.
New Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the
construction techniques provide a full R-38 insulation value over the wall top plate. The design provides a full
R-38 insulation value over the wall top plate as follows: Provide R62.4 at roof cavities with 5/8" plywood over
14" TJIs with 4" minimum of 2# closed cell spray foam insulation with an R value of 6.6 per inch equaling
R-26.4 and 12" of blown in cellulose insulation with R-3.6 per inch equaling R-36.
Existing Exterior Walls Insulation - To remain.
New Exterior Walls Insulation - Requires R-20: Exterior walls with 5.5" cavity: Provide R-25.8 with 2" of poly
iso spray foam insulation @ inside of sheathing with an R value of 6.6 per inch equaling R-13.2 and 3.5" of
blown in cellulose insulation with an R value of R-3.6 per inch equaling R-12.6 or approved equal
CODE INFORMATION
PROJECT INFORMATION
ARCHITECT
BERGLUND ARCHITECTS, LLC
P.O. Box 2378
210 Edwards Village Blvd
Suite A103
Edwards, CO 81632
Phone: (970) 926-4301
Fax: (970) 926-4364
hans@berglundarchitects.com
STRUCTURAL
ENGINEER
CLIENTS
CONTRACTOR
PROJECT DESCRIPTION
GENERAL NOTES
The Mark A. Neoprent 2009
Qualified Personal Residence
Trust and The Lisa King
Neoprent 2009 Qualified
Personal Residence Trust
11 Terrace Circle
Armonk, NY 10504
Phone: (914) 924-3781
lisaneoperent@gmail.com
mneoprent@gmail.com
BECK BUILDING COMPANY
780 Nottingham Rd.
Avon, CO. 81652
Phone: (970) 949-1800
KRM Consultants Inc.
P.O. Box 4572
Vail, Co 21658
Phone: (970) 949-9391
Fax: (970) 949-0839
tdh@krmconsuktants.com
As indicated
12/18/2018 1:59:28 PMA1.0
COVER
SHEET
HS
AG
NEPORENT RESIDENCE
12/18/2018
FINAL DRB SUBMITTAL
12/18/2018
FINAL DRB SUBMITTALNEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EREVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
1/4/2019 12:00:00
AM
A4.1
A4.2
1
1
5' - 4"3' - 10"3' - 6"6' - 1 3/4" 6' - 4 1/4"14' - 6 1/4"
10' - 2"
OPENING
3' - 0" 6"
4' - 5 1/8"
OPENING 2' - 10"
3' - 3"
OPENING 2' - 4"
3' - 8 1/2"
9' - 5 3/8"5' - 8"NEW POWDER
102
NEW LAUNDRY
101
NEW KITCHEN
100
3' - 7" CLEAR(2) NEW 30" SUB
ZERO FRIDGES
UP DN
EXISTING BALCONY TO
BE DEMOLISHED
NEW 60" RANGE AND NEW HOOD
FILL IN
EXISTING
DOOR
A B C D E F
1
2
3
4
5
6
7
STORAGE
EXISTING WALLS TO BE
DEMOLISHED
EXISTING WALLS TO
BE DEMOLISHED
EXISTING FIREPLACE
TO BE DEMOLISHED
DESKFAX/PRINT/SCAN
W/ SLIDING SHELF
NEW CUSTOM BUILT-IN
FOR DESK AND STORAGE
RE USE EXISTING UNDERMOUNT TUBMAKEUPEXISTING WALL TO BE DEMOLISHED
OPAQUE GLASS @ W.C.
NEW ROBURN MEDICINE CABINET
NEW ROBURN MEDICINE CABINET
NEW CLOS. #2
106
NEW LARGER WINDOW TO REPLACE EXISTING
UP DN
EXISTING ENTRY
EXISTING LIVING
EXISTING
FORMAL DINING
8176' - 0"
8181' - 0" SUB FLOOR
NEW MASTER
BATHROOM
104
5' - 0 3/4" R.O. 1' - 2 7/8"
8176' - 0" SUB FLOOR
LINE OF NEW UPPER CABINETS
8176' - 0" SUB FLOOR
8176' - 1 1/4"
DN
EXISTING
ELEVATOR
3' - 2 1/4" 2' - 8 3/4" R.O. 4' - 3" 2' - 8 3/4" R.O.3' - 1" CLEAR12' - 11 1/2"1
A5.1
NEW CLOS. #1
105
K
PROPOSE TO REUSE WINDOWS
RELOCATED FROM EXISTING
HALLWAY PLAN NORTH OF THE
ELEVATOR AT THESE LOCATIONS
EXISTING
COURTYARD
3' - 4"
1"5 1/2" 4' - 3" 3 1/2" 4' - 11" 3 1/2" 5' - 9 1/4" 3 1/2" 17' - 3 1/4"18' - 4" 16' - 1" 13' - 0 1/2" 10' - 6 1/2" 6' - 0"
EXISTING WINDOW TO BE
REMOVED, REPLACED W/ NEW
TWO PANEL LIFT AND SLIDE DOOR EXISTING WINDOW TO BE REMOVED
5' - 6"
7' - 2 1/4" 3 1/2" 7' - 2 1/4"1' - 10 1/2"6' - 11 1/2" 2' - 6" 3' - 6" 5 1/2" 7' - 11" 3 1/2" 1' - 5" 3' - 11 1/2" OPENING 2' - 4"
4' - 10" R.O.2' - 7 3/4" 4' - 10" R.O. 2' - 7 5/8"
1' - 3" 5' - 9 5/8" R.O. 3' - 2"13' - 2" VIF29' - 1 1/2"
8175' - 7 1/4"
6"
1"
FIREPLACE TO BE REMOVED
SHOWN BY DASHED LINE
LINE OF BUILT-IN TO BE REMOVED
SHOWN BY DASHED LINE
LINE OF BUILT-IN TO
BE REMOVED
FD
3' - 4" 4' - 6 1/2"
10' - 0" OPENING
2' - 6"FURNITURE 3
A5.2
1' - 9 11/16"
NEW FAMILY
DINING 10' - 0"5' - 0 1/4" 9' - 0" 3' - 6"10' - 11"3' - 10 1/4"
NEW INSWING PATIO DOOR,
TO ALIGN WITH CENTERLINE
OF WINDOW ABOVE
10' - 6 1/2"12' - 11 1/2" 12' - 10"
DOUBLE HANGING SHELVES &DRAWERSSINGLE HANGING
SHOE SHELF
DESK &
STORAGE
NEW TWO PANEL LIFT
AND SLIDE DOOR
2' - 1 7/8" 5' - 0 3/4"CLOS.
CLEAR GLASS
AT SHOWER
LINE OF WALL BELOW
EXISTING COLUMN - VERIFY
LOCATION AND SIZE
DASHED LINE OF EXISTING DECK ABOVE
EXISTING DECK STRUCTURE
EXISTING WALLS TO
BE DEMOLISHED
UP
14' - 2 1/4" 10' - 1" 15' - 0" 10' - 0" 10' - 6 1/2" 8' - 0"7' - 9"
EXISTING PILASTER AT FACE OF BUILDING
EXISTING COLUMN
HATCH REGION SHOWS
AREA OF ADDITION (25 SF)
SEE FOR MORE INFO
NEW MASTER
BEDROOM
103
-
1"
8' - 6 3/4" R.O. 3' - 1 3/4"
EXISTING DOOR AT NEW POWDERALIGN3' - 2 3/4" CLEAR
REUSE DOOR FROM KITCHEN
1
EXISTING DOWNSPOUT
EXISTING DOWNSPOUT
LOCATION
6 005
5
004
4003 13001
101A
103A
104A
104B
104C
105A 106A
DOUBLE SWING DOOR
/1 A3.4
2' - 6" OPENING
WOOD TILE WOOD TILEWOODTILE WOOD CARPETWOOD CARPET10
105
9104 9 103
DASHED LINE SHOWS
ROOF ABOVE
1
A8.3
1
A8.3
4
A8.1
NEW DOWNSPOUT
SEE FOR KITCHEN INTERIORS
SEE FOR
MASTER BATH INTERIORS
/ 1 A9.2
E4.1
1
- -E4.2 1
E4.3
1
1
A8.17' - 10" R.O.3' - 6 7/8"
1
A6.1
1' - 3 11/16" 10' - 1" R.O. 1' - 7 13/16"
EXISTING 2' - 10" R.O. 1' - 6 5/8"9" 2' - 8" R.O. 7"
3' - 2" R.O. 5"
EXISTING HOSE BIB
SEE FOR INTERIORS/ 1 A9.5
W D
/1 A9.1 1"8176' - 2 1/4" FINISH FLOOR
8176' - 2 1/4" FINISH FLOOR
8181' - 2 1/4" FINISH FLOOR
A8.2
2
6
A8.2
1' - 6"
SEE FOR
INTERIORS
/1 A9.5 3 DOORS ON DOUBLEBYPASS DOOR TRACKTAG INDICATES NEW WINDOWS, TYP.
DWTR
DW
ICE
MICROWAVE
DRAWER
CUSTOM BUILT IN BED
STAND AND STORAGE
1
1
1
A1.0
1
4' - 3 1/2"
SEE FOR
MASTER BEDROOM
INTERIORS
/ 1 A9.6
CLG CHANGE ABOVE
BENCH
1/8" : 12"
LINE OF CLG CHANGE ABOVE SHELVES &DRAWERS12001 13001
2' - 11 3/4" 67' - 9 3/4"64' - 0"
29' - 7"24' - 3 1/4" 18' - 6 1/2"25' - 0" 3
A5.1
4
A5.2
2
A5.2
WOOD FRAMED WALLS, FLOORS,
AND, ROOFS AND COLUMNS SHOWN
WHITE WITH SOLID BLACK LINES
AREA OF ADDITION
CONCRETE WALL SHOWN WITH HATCH
EXISTING WALL
NEW WALL
DEMOLISHED
GENERAL NOTES:
1. FLOOR TO FLOOR HEIGHTS ARE APPROXIMATE; VERIFY ALL EXISTING FLOOR TO
FLOOR HEIGHTS, ASSEMBLIES, AND RADIANT HEAT INSTALLATION METHODS
PRIOR TO CONSTRUCTION.
2. AREA OF ADDITION SHOWN WITH DIAGONAL HATCH PATTERN.
3. EXTERIOR LIGHTING AS NOTED.
4. SEE A10.2 - A10.3 FOR RCPs. SEE A8.0 - A8.3 FOR WINDOW DETAILS.
5. SEE ELEVATIONS FOR ALL EXTERIOR MATERIAL CALL OUTS.
6. VERIFY ALL EXISTING WALL, ROOF, WINDOW, AND DOOR LOCATIONS/
DIMENSIONS/ASSEMBLIES AND COORDINATE ANY DISCREPANCIES WITH
ARCHITECT.
7. ALL FREESTANDING FURNITURE AND DECORATIVE LIGHT FIXTURES TO BE
PROVIDED BY OWNER.
8. PROVIDE MIN 4 1/2" FROM INTERIOR DOOR R.O. TO ADJACENT PERPENDICULAR
WALL. TYP U.N.O
9. DOWNSPOUTS TO BE RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT BEYOND
LIMITS OF EXCAVATION. PROVIDE HEAT TAPE TYP.
10. VERIFY ALL INTERIOR FIXED FINISHES WITH INTERIOR DESIGNER.
11. ALL WINDOWS, DOORS, PLUMBING, CABINETS, STRUCTURE, FINISHES, ETC ARE
EXISTING UNLESS NOTED OTHERWISE
GENERAL DEMOLITION NOTES:
1. COORDINATE THE REMOVAL OF PERSONAL ITEMS, FURNISHINGS, AND
APPLIANCES FROM NECESSARY AREAS PER OWNERS DIRECTION.
2. GENERAL CONTRACTOR SHALL SALVAGE AND PROTECT FOR REUSE ANY NOTED
OWNER ITEMS BEFORE DEMOLITION. SEE THE LIST OF ITEMS TO BE REMOVED
AND REUSED. SALVAGED ITEMS FOR RE-USE INCLUDE, BUT MAY NOT BE LIMITED
TO, CABINETRY, APPLIANCES, PLUMBING FIXTURES, AND LIGHTING FIXTURES AS
INDICATED IN DRAWINGS AND SCHEDULE. ALL ITEMS TO BE VERIFIED BY OWNER
PRIOR TO REINSTALL.
3. GENERAL CONTRACTOR TO COORDINATE APPROPRIATE DISCONTINUANCE AND
OR RELOCATION OF ALL REQUIRED UTILITIES BEFORE DEMOLITION.
4. CONTRACTOR TO ARRANGE SUFFICIENT VENTILATION DURING DEMOLITION TO
PROTECT INDOOR AIR QUALITY IN THE HOME.
5. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL
REMAINING FINISHES WITHIN THE UNIT AS REQUIRED TO AVOID DAMAGE.
6. STRUCTURAL COMPONENTS (COLUMNS, BEAMS) TO REMAIN UNMODIFIED UNLESS
OTHERWISE NOTED; SEE STRUCTURAL DRAWINGS FROM STRUCTURAL ENGINEER
FOR ALL MODIFICATIONS TO STRUCTURAL COMPONENTS.
7. MAINTAIN EXISTING MECHANICAL CHASES AND CORRESPONDING RATED WALL
ASSEMBLIES UNLESS NOTED OTHERWISE.
8. GENERAL CONTRACTOR SHALL VERIFY EXTENT OF MECHANICAL, ELECTRICAL,
AND PLUMBING DEMOLITION AND COORDINATE AS NECESSARY.
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:29 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA3.2
MAIN
LEVEL
FLOOR
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
0' 4' 8' 16' 32'
NORTH
1/4" = 1'-0"1 MAIN LEVEL FLOOR PLAN
1/4" = 1'-0"
WALL SCHEDULE
REVISION SCHEDULE
# DESCRIPTION DATE
PLAN KEY NOTES:
PRICE PATCHING EXISTING WOOD FLOOR @ THE EXISTING GUEST MASTER PER
THE PROPOSED RENOVATION TO BE THE "NEW MASTER." ENTIRE FLOOR TO
BE REFINISHED. COMPARE THIS COST TO COST OF ALL NEW FLOOR. NOTE
EXISTING HEAT TUBING IN FLOOR NOT TO BE MODIFIED OTHER THAN MINOR
PATCHING AS REQUIRED.
1
DRB
APPROVED
1/4/2019 12:00:00
AM
A4.1
A4.2
1
2' - 11 1/16"3 1/2"4' - 3 1/2"2' - 0"2' - 0" 5' - 8"
6' - 1"
EXISTING DECK
EXISTING DECK
13' - 10 1/4" 3' - 6" 7' - 1 1/2"2 1/2" 3' - 6" 7' - 1 3/8" NEW GUEST
ROOM #1
202
NEW STOR.
CLOS.
NEW GUEST
BATH #2
201
NEW GUEST
ROOM #2
200
EXISTING CLOS.
NEW GUEST
BATH #1
203
NEW GUEST HALL
EXISTING MAIN
STAIR7' - 8" 2' - 8" OPENING1' - 0"2' - 10" OPENING
5 5/8" 2' - 10" OPENING 7' - 2 1/2"4 1/2" 2' - 8" OPENING 7' - 10"A B C D E F
1
2
3
4
5
6
7 BENCHBENCHW/D
7' - 0 13/16" 12' - 4 1/2" ART
EXISTING
BEDROOM
EXISTING
BEDROOM
EXISTING STUDY
EXISTING HALL
8189' - 0" SUB FLOOR
EXISTING
WALLS TO BE
DEMOLISHED
K
K
6 1/2" 6' - 0" OPENING 1' - 2 1/2" 3' - 0" R.O.
10 1/2"
6 1/2"6' - 0" OPENING
3' - 0" WINDOW
4' - 11 3/4" 3' - 0 3/4" R.O. 5' - 10 1/2"
EXISTING WALLS TO
BE DEMOLISHED
EXISTING
ELEVATOR
DN
PROPOSED NEW
WINDOW LOCATION
1
EXISTING WALL TO
BE DEMOLISHED
EXISTING
COURTYARD
EXISTING
BATHROOM
EXISTING
BATHROOM
EXISTING DECK
6' - 0 1/2"3
COORDINATE WALL
LOCATION WITH TRIM AT
EXISTING WINDOW DO NOT
ALTER EXISTING TRIM
PLUMBING FOR WASHER
AND DRYER
2' - 7 3/4" 3' - 11 3/8"FURNITURE FURNITURE18' - 4" 16' - 1" 13' - 0 1/2" 10' - 6 1/2" 6' - 0"15' - 0" 10' - 0" 10' - 6 1/2" 8' - 0"LINE OF EXISTING ROOF
CONNECTIONS FOR
WASHER AND DRYER
PROPOSED TRELLIS
SEE FOR MORE INFO/1 A3.5
EXISTING ART
1
7
101
200A 200B
201A
201B202A 202B
203A
203B
WOOD TILE
WOOD TILE
SEE FOR
INTERIOR ELEVATIONS
/1 A9.3
SEE FOR
INTERIOR ELEVATIONS
/1 A9.4 WOOD CARPETWOOD CARPET - -E4.2 1
E4.3
12' - 10" R.O.3' - 0" R.O. 3' - 2 9/16"
11' - 7 1/2"2' - 10" R.O.EXISTING DOWNSPOUT
LOCATION
EXISTING DOWNSPOUT
LOCATION
1' - 6"
1' - 6"
SEE FOR
INTERIOR ELEVATIONS
/ 7 A9.5
8189' - 2 1/4" FINISH FLOOR
2
2
3" / 12"
2
A6.2
1
A6.2
EXISTING FIREPLACE VENT TO
REMAIN @ EXTERIOR. CLOSE
AND SEAL OFF AT INTERIOR
2
A1.0
1
DS
FD
FD12' - 4"13' - 3 3/16"
64' - 0"43' - 6 1/2"10' - 6 3/16"
3
A5.1
4
A5.2
2
A5.2
WOOD FRAMED WALLS, FLOORS,
AND, ROOFS AND COLUMNS SHOWN
WHITE WITH SOLID BLACK LINES
AREA OF ADDITION
CONCRETE WALL SHOWN WITH HATCH
EXISTING WALL
NEW WALL
DEMOLISHED
GENERAL NOTES:
1. FLOOR TO FLOOR HEIGHTS ARE APPROXIMATE; VERIFY ALL EXISTING FLOOR TO
FLOOR HEIGHTS, ASSEMBLIES, AND RADIANT HEAT INSTALLATION METHODS
PRIOR TO CONSTRUCTION.
2. AREA OF ADDITION SHOWN WITH DIAGONAL HATCH PATTERN.
3. EXTERIOR LIGHTING AS NOTED.
4. SEE A10.2 - A10.3 FOR RCPs. SEE A8.0 - A8.3 FOR WINDOW DETAILS.
5. SEE ELEVATIONS FOR ALL EXTERIOR MATERIAL CALL OUTS.
6. VERIFY ALL EXISTING WALL, ROOF, WINDOW, AND DOOR LOCATIONS/
DIMENSIONS/ASSEMBLIES AND COORDINATE ANY DISCREPANCIES WITH
ARCHITECT.
7. ALL FREESTANDING FURNITURE AND DECORATIVE LIGHT FIXTURES TO BE
PROVIDED BY OWNER.
8. PROVIDE MIN 4 1/2" FROM INTERIOR DOOR R.O. TO ADJACENT PERPENDICULAR
WALL. TYP U.N.O
9. DOWNSPOUTS TO BE RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT BEYOND
LIMITS OF EXCAVATION. PROVIDE HEAT TAPE TYP.
10. VERIFY ALL INTERIOR FIXED FINISHES WITH INTERIOR DESIGNER.
11. ALL WINDOWS, DOORS, PLUMBING, CABINETS, STRUCTURE, FINISHES, ETC ARE
EXISTING UNLESS NOTED OTHERWISE
GENERAL DEMOLITION NOTES:
1. COORDINATE THE REMOVAL OF PERSONAL ITEMS, FURNISHINGS, AND
APPLIANCES FROM NECESSARY AREAS PER OWNERS DIRECTION.
2. GENERAL CONTRACTOR SHALL SALVAGE AND PROTECT FOR REUSE ANY NOTED
OWNER ITEMS BEFORE DEMOLITION. SEE THE LIST OF ITEMS TO BE REMOVED
AND REUSED. SALVAGED ITEMS FOR RE-USE INCLUDE, BUT MAY NOT BE LIMITED
TO, CABINETRY, APPLIANCES, PLUMBING FIXTURES, AND LIGHTING FIXTURES AS
INDICATED IN DRAWINGS AND SCHEDULE. ALL ITEMS TO BE VERIFIED BY OWNER
PRIOR TO REINSTALL.
3. GENERAL CONTRACTOR TO COORDINATE APPROPRIATE DISCONTINUANCE AND
OR RELOCATION OF ALL REQUIRED UTILITIES BEFORE DEMOLITION.
4. CONTRACTOR TO ARRANGE SUFFICIENT VENTILATION DURING DEMOLITION TO
PROTECT INDOOR AIR QUALITY IN THE HOME.
5. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL
REMAINING FINISHES WITHIN THE UNIT AS REQUIRED TO AVOID DAMAGE.
6. STRUCTURAL COMPONENTS (COLUMNS, BEAMS) TO REMAIN UNMODIFIED UNLESS
OTHERWISE NOTED; SEE STRUCTURAL DRAWINGS FROM STRUCTURAL ENGINEER
FOR ALL MODIFICATIONS TO STRUCTURAL COMPONENTS.
7. MAINTAIN EXISTING MECHANICAL CHASES AND CORRESPONDING RATED WALL
ASSEMBLIES UNLESS NOTED OTHERWISE.
8. GENERAL CONTRACTOR SHALL VERIFY EXTENT OF MECHANICAL, ELECTRICAL,
AND PLUMBING DEMOLITION AND COORDINATE AS NECESSARY.
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:29 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA3.3
UPPER
LEVEL
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
0' 2' 4' 8' 16'
1/4" = 1'-0"1 UPPER LEVEL FLOOR PLAN
1/4" = 1'-0"
WALL SCHEDULE
REVISION SCHEDULE
# DESCRIPTION DATE
PLAN KEY NOTES:
HEAT TUBING IN EXISTING MASTER BEDROOM SUITE PROPOSED TO REMAIN AS
IS EXCEPT FOR MINOR PATCHING OF TUBING AS REQUIRED PER WALL DEMO
ETC. NOTE THE TWO GUEST ROOMS & BATHROOMS WILL ALL BE ON ONE ZONE.
VERIFY NEW THERMOSTAT LOCATION W/ OWNER.
2
DRB
APPROVED
1/4/2019 12:00:00
AM
A B C D E F
1
2
3
4
5
6
7
LINE OF EXISTING WALL
NEW WALL
RED REGION
SHOWS 25 SF OF
ADDITIONAL AREA
2' - 6"10' - 0"US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 2:35:41 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA3.4
ADDITION
DIAGRAM
MAIN
LEVEL
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
1/4" = 1'-0"1 MAIN LEVEL ADDITION PLAN
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
1/4/2019 12:00:00
AM
1
3
A5.2
NOTE: ALL MEASUREMENTS ARE
TO FINISH OR CENTERLINE OF
DOUBLE C-CHANNEL TRELLIS
MEMBER VERIFY IN FIELD
TOP TRELLIS MEMBERS ARE TO
STOP 10" SHORT OF FINISH
TYPICAL
HEAT STRIP @ TRELLIS
PATIO HEATERS
J-BOX FOR FAN @ TRELLIS
HEAT STRIP @ TRELLIS
PATIO HEATERS
HEAT STRIP @ TRELLIS PATIO HEATERS
HEAT STRIP @ TRELLIS
PATIO HEATERS
1
3' - 7 7/16" 6' - 0" 6' - 0" 6' - 0"EQEQ A6.3
1
A6.3
1
A6.3
1
A6.3
1
A6.3
1
A6.3
1
C6X10.5C4X4.5
3' - 3 1/4" 4' - 10 1/2" 4' - 6 1/2" 2' - 1 1/4"
TYP
10"
TYP
10"
10"
C4X4.5 C6X10.5C6X10.5C4X4.5
1
A6.3
6
A8.2
A9.53
DOWNSPOUT
GUTTER
3" / 12"
LINE OF WALL BELOW
J-
BOX
3
A5.1
4
A5.2
2
A5.2
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:30 PM1/2" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA3.5
TRELLIS
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
1/2" = 1'-0"1 TRELLIS PLAN
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
1/4/2019 12:00:00
AM
GENERAL NOTES:
1) PROVIDE NEW SNOW FENCES AND SNOW GUARDS PER CONVERSATIONS
W/ OWNER TO REDUCE RISK OF SNOW SHEDDING.
2) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
3) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH FLOOR.
4) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS
5) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO
BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE.
6) ALL WINDOWS AND FINISHES ARE EXISTING EXCEPT FOR NEW WINDOWS/
DOORS AND FINISHES AS NOTED. NEW WINDOWS AND DOORS HAVE
SYMBOL.
7) PROTECT EXISTING ADJACENT FINISHES.
8) INTEGRATE/ BLEND NEW FINISHES W/ EXISTING.
9) MATCH EXISTING FINISHES AS NOTED. PROVIDE SAMPLES AND MOCKUP
PRIOR TO STARTING WORK.
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
AB CD E F
1
T.O. WINDOW 10' - 0" AFF3' - 6" WINDOW SILL AFF NEW WINDOW IN GUEST BATH #2
7' - 0 1/2"EXISTING PATIO DOOR TO BE
REMOVED SHOWN DASHED
DASHED LINES SHOW EXISTING
WINDOWS TO BE REMOVED, TYP.
NEW WINDOWS, SHOWN W/
TAG, TYP.
NEW TWO PANEL SLIDING DOOR
7' - 9" LIFT AND SLIDE WIDTH
2' - 10" WINDOW WIDTH
ALIGN
2' - 10" WINDOW WIDTH
ALIGN
EXISTING STONE VENEER
EXISTING POLISHED CUT STONE PANELS
EXISTING STONE VENEER
EXISTING COPPER CLAD PANELS
UNIT A
EAST
UNIT B
WEST
NOTE: UNIT B NOT
SHOWN FOR
CLARITY
DASHED LINE SHOWS
EXISTING DOWNSPOUT
LOCATION TO REMAIN
EXISTING POLISHED CUT STONE PANELS
EXISTING VERTICAL WOOD SIDING
EXISTING COPPER PANELING
DASHED LINE SHOWS
EXISTING DOWNSPOUT
6' - 10 3/8" 3"7' - 0"12001 13001
4003
7101
6' - 6" HEIGHT OF WINDOW8' - 6 3/4" R.O.10' - 0" LIFT AND SLIDE HEIGHT1
A8.3 EXISTING WINDOW WELLEXISTING
WINDOW WELL
EXISTING COPPER CLAD PANELS
T.O. WINDOW 7' - 0" AFF4' - 0" WINDOW SILL AFF 3' - 0" WINDOW HEIGHT3' - 0" WINDOW WIDTH
3' - 0 3/4" R.O.
3
A8.1
2
A8.1 1
A8.1
2
A8.3
18' - 4"16' - 1" 13' - 0 1/2" 10' - 6 1/2" 6' - 0" 10' - 0 3/4" B.O. WINDOW HEADER AFF10' - 1" B.O. DOOR HEADER AFF7' - 10" DOOR R.O.7' - 0 3/4" B.O. WINDOW HEADER AFF13' - 0"SDL @ 7' - 0" AFFAREA OF STONE VENEER
TO BE ADDED/ REPLACED
TO MATCH EXISTING
SHOWN W/ CROSS HATCH
13001
2' - 10" WINDOW WIDTH
64' - 0"
3
A5.1
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 2:07:25 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA4.1
ELEVATIONS
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
0' 4' 8' 16' 32'
1/4" = 1'-0" 1 SOUTH ELEVATION
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
1/4/2019 12:00:00
AM
GENERAL NOTES:
1) PROVIDE NEW SNOW FENCES AND SNOW GUARDS PER CONVERSATIONS
W/ OWNER TO REDUCE RISK OF SNOW SHEDDING.
2) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
3) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH FLOOR.
4) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS
5) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO
BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE.
6) ALL WINDOWS AND FINISHES ARE EXISTING EXCEPT FOR NEW WINDOWS/
DOORS AND FINISHES AS NOTED. NEW WINDOWS AND DOORS HAVE
SYMBOL.
7) PROTECT EXISTING ADJACENT FINISHES.
8) INTEGRATE/ BLEND NEW FINISHES W/ EXISTING.
9) MATCH EXISTING FINISHES AS NOTED. PROVIDE SAMPLES AND MOCKUP
PRIOR TO STARTING WORK.
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
A B C D E F
MASTER LEVEL
F.F
8181' - 2 1/4"
1
PROPOSED NEW WINDOW IN MASTER BATH
5' - 0" WINDOW WIDTH
LINE OF NEW WINDOW BEYOND ROOF
LINE OF EXISTING WINDOW TO BE REMOVED
EXISTING STONE VENEER
EXISTING COPPER CLAD PANEL
EXISTING STONE VENEER
EXISTING POLISHED CUT STONE PANELS
EXISTING COPPER CLAD PANELS
EXISTING POLISHED CUT
STONE PANELS
EXISTING VERTICAL WOOD SIDING
UNIT A
EAST
UNIT B
WEST
NOTE: UNIT B NOT
SHOWN FOR
CLARITY
DASHED LINE SHOWS EXISTING
DOWNSPOUT LOCATION
10105 3' - 9" WINDOW HEIGHTWINDOW SILL HEIGHT NOT TO CHANGE DUE TO EXISTING MATERIALS. V.I.F.T.O. WINDOW 6' - 9 1/16" AFF3
A8.1
2
A8.1
1
A8.1
SIM
18' - 4" 16' - 1" 13' - 0 1/2" 10' - 6 1/2" 6' - 0"
5' - 0 3/4" R.O.8' - 0"5' - 0" 13' - 0"6' - 9 13/16" WINDOW R.O.CROSSHATCH SHOWS AREA OF GRANITE
CLADDING TO BE REPLACED PER NEW WINDOW
64' - 0"
3
A5.1
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 2:07:51 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA4.2
ELEVATIONS
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
0' 2' 4' 8' 16'
1/4" = 1'-0"1 NORTH ELEVATION
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
1/4/2019 12:00:00
AM
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
LOWER LEVEL F.F.
8165' - 2 1/4"
1 3 4 5 7
MASTER LEVEL
F.F
8181' - 2 1/4"10' - 0" AFFGARAGE LEVEL
F.F.
8170' - 2 1/4"
NEW CLOS. #1
EXISTING
BALCONY TO BE
DEMOLISHED
EXISTING LOWER
LEVEL 1"13' - 0"11' - 0" EXISTING HALLEXISTING
BATHROOM
EXISTING
GARAGEB.O. CLG 11' - 5" A.F.F.NEW
SLOPED
CEILING
NEW WALL
NEW CEILING
3
2' - 0"
EXISTING
WINDOWS TO
BE REMOVED
NEW PATIO
DOOR
EXISTING COPPER CLAD PANELS
EXISTING POLISHED CUT STONE PANELS
OPENING
2' - 10"EXISTING STONE VENEER
4" / 12"6' - 1 3/4"NEW TRELLIS SEE FOR MORE INFO
NEW MASTER
BEDROOM
1
/ 1 A3.5
6
005
8' - 2 7/8" B.O. DOOR HEADER AFF2' - 10 3/4" R.O.
4
A8.1
EXISTING WINDOW WELL
A6.3
1
10' - 4 3/4" BOTTOM OF DOUBLE C-CHANNELA8.3
1
A8.3
1 9' - 6" BOTTOM OF HEATER8' - 9 9/16" VIF13' - 9 7/16" TOP OF WALLNEW FAMILY
DINING
3
A8.1A6.3
1
2
A8.3
2
A8.3
A6.3
1
5
A8.1
A8.1
3
2
A8.1A8.1
1
18' - 6 1/2" 10' - 0" 15' - 0" 24' - 3 1/4"
SEE FOR INFORMATION
ON KITCHEN INTERIORS
/ 1 A9.1 24' - 0"8' - 0"5' - 0" 6' - 0" 5' - 0" 67' - 9 3/4"
EXISTING CONSTRUCTION V.I.F.1"EXISTING
CONSTRUCTION V.I.F.
ALL STONE IN THIS AREA IS NEW
ALL STONE IN THIS AREA IS NEW
EXISTING GRANITE TO REMAIN
11111ALIGN
1
A6.2
A9.6
2
DS
SEE FOR INFORMATION
ON KITCHEN INTERIORS
/ 1 A9.6
1
A6.1
A6.2
21' - 0"
25' - 0"
WALL JOG AT NEW ADDITION
A5.1
3
4
A5.2
2
A5.2
WOOD FRAMED WALLS, FLOORS,
AND, ROOFS AND COLUMNS SHOWN
WHITE WITH SOLID BLACK LINES
AREA OF ADDITION
CONCRETE WALL SHOWN WITH HATCH
EXISTING WALL
NEW WALL
DEMOLISHED
GENERAL NOTES:
1) PROVIDE NEW SNOW FENCES AND SNOW GUARDS PER CONVERSATIONS
W/ OWNER TO REDUCE RISK OF SNOW SHEDDING.
2) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
3) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH FLOOR.
4) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS
5) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO
BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE.
6) ALL WINDOWS AND FINISHES ARE EXISTING EXCEPT FOR NEW WINDOWS/
DOORS AND FINISHES AS NOTED. NEW WINDOWS AND DOORS HAVE
SYMBOL.
7) PROTECT EXISTING ADJACENT FINISHES.
8) INTEGRATE/ BLEND NEW FINISHES W/ EXISTING.
9) MATCH EXISTING FINISHES AS NOTED. PROVIDE SAMPLES AND MOCKUP
PRIOR TO STARTING WORK.
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
3 4 5
MASTER LEVEL
F.F
8181' - 2 1/4"
3 1
10' - 0" AFF1"13' - 0"NEW PATIO DOOR
EXISTING COPPER CLAD PANELS
EXISTING POLISHED CUT STONE PANELS
OPENING
2' - 10"
EXISTING STONE VENEER
NEW TRELLIS SEE
FOR MORE INFO
/ 1 A3.5
6005
8' - 2 7/8" B.O. DOOR HEADER AFF2' - 10 3/4" R.O.
4
A8.1
A6.3
1
10' - 4 3/4" BOTTOM OF DOUBLE C-CHANNELA8.3
1 9' - 6" BOTTOM OF HEATER3
A8.1A6.3
1
2
A8.3
A6.3
1
5
A8.1
10' - 0" 15' - 0"8' - 0"5' - 0" EXISTING CONSTRUCTION V.I.F.
ALL STONE IN THIS AREA IS NEW
ALL STONE IN THIS AREA IS NEW
EXISTING GRANITE TO REMAIN
11111ALIGN
1
A6.2
DS
1
A6.1
A6.2
21' - 0"
25' - 0"
WALL JOG AT NEW ADDITION
4
A5.2
2
A5.2
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:44 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA5.1
BUILDING
SECTIONS
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
1/4" = 1'-0"1 COURTYARD SECTION 2
1/4" = 1'-0"
WALL SCHEDULE
REVISION SCHEDULE
# DESCRIPTION DATE
2 COURTYARD VIEW #1
1/4" = 1'-0"3 COURTYARD SECTION 2 Complete
DRB
APPROVED
1/4/2019 12:00:00
AM
CD E F
1
EXISTING
MECHANICAL
EXISTING STUDY
DASHED LINE SHOWS
BALCONY TO BE REMOVED
EXISTING COPPER PANELS
EXISTING GRANITE TO REMAIN
PROPOSED TRELLIS
SEE FOR
MORE INFO.
EXISTING STONE VENEER
/ 1 A3.5 9
103
9
104
2' - 8 3/4" R.O.
A8.1
3
5
A8.1
A8.1
4
A6.3
1
3
A8.1
2
A8.1
1
A8.1
13' - 0 1/2"10' - 6 1/2" 6' - 0" 13' - 0"NEW INSWING PATIO DOOR
EXISTING WINDOWS
RELOCATED TO THIS WALL
FROM DEMOLISHED
COURTYARD WALL @ ADDITION.
VERIFY DIMENSIONS AND IF
WINDOWS CAN BE REUSED.
2' - 8"
APPROX. LINE OF
EXISTING SEAM IN
STONE PANELING
AREA OF NEW STONE
VENEER TO MATCH EXISTING
BLEND INTO EXISTING
29' - 7"3
A5.1
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
C D E F
1
NEW LAUNDRY
NEW POWDER
EXISTING WALL TO
BE DEMOLISHED
SHOWN BY DASHED
LINE
EXISTING WINDOWS AND
DOORS TO BE REMOVED
SHOWN BY DASHED LINE TYP
NEW FOUNDATION RE: STRUCT
NEW WALL
EXISTING STUDY
EXISTING
MECHANICAL10' - 0" DOOR HEIGHT1' - 2 3/16"
NEW SLIDING DOOR
PROPOSED NEW
TRELLIS FOR MORE
INFO SEE .
PROPOSED NEW
HEAT STRIP AT
TRELLIS
NEW PORTION OF PATIO
NEW CONCRETE SLAB AND FLOOR UNDER ADDITION
EXISTING PORTION OF PATIO TO REMAIN
10' - 0" DOOR WIDTH
ALIGN WITH MULLION AT
SLIDING DOOR @
SOUTH ELEVATION
/ 1 A3.5
3"6' - 10 3/8" 5004
1
A8.3
TOP OF SLAB 8176' - 1 1/4"
TOP OF FOOTER 8173' - 2"13' - 0"13' - 0 1/2" 10' - 6 1/2" 6' - 0"B.O. CLG 11' - 8 1/2" A.F.F.6"10' - 3 3/4" B.O. DOUBLE C-CHANNEL AFF A6.1
1
2
A8.3
A6.3
1
1"10' - 1" DOOR R.O.8176' - 7 3/4" TOP OF WALL
EXISTING
STRUCTURAL
STEEL
EXISTING
WINDOWS TO
REMAIN
MATCH EXISTING
ALL STONE VENEER IN THIS AREA IS NEW
EXISTING GRANITE TO REMAIN
A6.2
1EXISTING GRANITE TO REMAINSEE FOR
INFORMATION ON
POWDER AND LAUNDRY
INTERIORS
/ 1 A9.5 B.O. CLG 11' - 8 1/2" A.F.F.3"
12"
3' - 6 3/4"
29' - 7"
16' - 6 1/2"
3
A5.1
WOOD FRAMED WALLS, FLOORS, AND,
ROOFS AND COLUMNS SHOWN WHITE WITH
SOLID BLACK LINES
STONE VENEER SHOWN WITH DIAGONAL HATCH
CONCRETE WALL SHOWN WITH HATCH
DEMOLISHED
NEW STONE VENEER SHOWN WITH TRANSPARENT
DIAGONAL HATCH
GENERAL NOTES:
1) PROVIDE NEW SNOW FENCES AND SNOW GUARDS PER CONVERSATIONS
W/ OWNER TO REDUCE RISK OF SNOW SHEDDING.
2) ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
3) WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH FLOOR.
4) SEE SHEET A4.1 FOR TYP. MATERIAL CALLOUTS
5) ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO
BE PAINTED TO MATCH BLUE/BLACK STEEL SAMPLE.
6) ALL WINDOWS AND FINISHES ARE EXISTING EXCEPT FOR NEW WINDOWS/
DOORS AND FINISHES AS NOTED. NEW WINDOWS AND DOORS HAVE
SYMBOL.
7) PROTECT EXISTING ADJACENT FINISHES.
8) INTEGRATE/ BLEND NEW FINISHES W/ EXISTING.
9) MATCH EXISTING FINISHES AS NOTED. PROVIDE SAMPLES AND MOCKUP
PRIOR TO STARTING WORK.
MAIN LEVEL F.F.
8176' - 2 1/4"
UPPER LEVEL F.F.
8189' - 2 1/4"
C D13
A5.1 10' - 0" DOOR HEIGHT1' - 2 3/16"
NEW SLIDING DOOR
PROPOSED NEW
TRELLIS FOR MORE
INFO SEE .
PROPOSED NEW
HEAT STRIP AT
TRELLIS
EXISTING PORTION OF PATIO TO REMAIN
10' - 0" DOOR WIDTH
ALIGN WITH MULLION AT
SLIDING DOOR @
SOUTH ELEVATION
/ 1 A3.5
5
004
1
A8.313' - 0"13' - 0 1/2"6"10' - 3 3/4" B.O. DOUBLE C-CHANNEL AFF 2
A8.3
A6.3
1
1"10' - 1" DOOR R.O.EXISTING
WINDOWS TO
REMAIN
MATCH EXISTING
ALL STONE VENEER IN THIS AREA IS NEW
EXISTING GRANITE TO REMAIN
A6.2
1
EXISTING GRANITE TO REMAINB.O. CLG 11' - 8 1/2" A.F.F.CD
13
A5.1
EXISTING COPPER PANELS
EXISTING GRANITE TO REMAIN
PROPOSED TRELLIS
SEE FOR
MORE INFO.
EXISTING STONE VENEER
/ 1 A3.5 9103 9104
2' - 8 3/4" R.O.
A8.1
3
5
A8.1
A8.1
4
A6.3
1
3
A8.1
2
A8.1
1
A8.1
13' - 0 1/2"
EXISTING WINDOWS
RELOCATED TO THIS WALL
FROM DEMOLISHED
COURTYARD WALL @ ADDITION.
VERIFY DIMENSIONS AND IF
WINDOWS CAN BE REUSED.
2' - 8"
APPROX. LINE OF EXISTING
SEAM IN STONE PANELING
EXISTING GRANITE TO REMAIN
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:51 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EA5.2
BUILDING
SECTIONS
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
1/4" = 1'-0"1 COURTYARD SECTION 3
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0"3 COURTYARD SECTION 1
1/4" = 1'-0"
WALL, FLOOR, AND ROOF LEGEND
5 COURTYARD VIEW #2
6 COURTYARD VIEW #3
1/4" = 1'-0"4 COURTYARD SECTION 1 Complete
1/4" = 1'-0"2 COURTYARD SECTION 3 Complete
DRB
APPROVED
1/4/2019 12:00:00
AM
E4.1
1
WEST UNIT NOT SHOWN FOR CLARITY
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:51 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE3.1
EXISTING
LOWER
LEVEL
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0" 1 EXISTING LOWER LEVEL FLOOR PLAN
EXISTING DRAWINGS INCLUDED FOR REFERENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM
WEST UNIT NOT SHOWN FOR CLARITY
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:52 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE3.2
EXISTING
MAIN
LEVEL
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0" 1 EXISTING MAIN LEVEL FLOOR PLAN
EXISTING DRAWINGS INCLUDED FOR REFERENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM
WEST UNIT NOT SHOWN FOR CLARITY
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:52 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE3.3
EXISTING
UPPER
LEVEL
PLAN
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0"1 EXISTING UPPER LEVEL FLOOR PLAN
EXISTING DRAWINGS INCLUDED FOR REFERENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM
WEST UNIT NOT SHOWN FOR CLARITY
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:54 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE4.1
EXISTING
SOUTH
ELEVATION
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0"1 EXISTING SOUTH ELEVATION
EXISTING DRAWINGS INCLUDED FOR REFRENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:54 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE4.2
EXISTING
EAST
ELEVATION
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0" 1 EXISTING EAST ELEVATION
EXISTING DRAWINGS INCLUDED FOR REFRENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM
WEST UNIT NOT SHOWN FOR CLARITY
US Mail Only: P. O. Box 2378Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
12/18/2018 1:59:55 PM1/4" = 1'-0"NEPORENT RESIDENCE184 BEAVER DAM RD, VAIL VILLAGEFILING 1, BLOCK 7, LOT 24EE4.3
EXISTING
NORTH
ELEVATION
SMM
AG
12/18/2018
FINAL DRB SUBMITTAL
REVISION SCHEDULE
# DESCRIPTION DATE
1/4" = 1'-0" 1 EXISTING NORTH ELEVATION
EXISTING DRAWINGS INCLUDED FOR REFRENCE ONLY
DRB
APPROVED
1/4/2019 12:00:00
AM