Loading...
HomeMy WebLinkAboutDRB19-0005_approved plans_1549562333.pdfEXISTING VAIL FIRE STATION #3 NEW BACK-UP GENERATOR ENCLOSURE GENERATOR ENCLOSURE LOCATION VFS #3 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.00 COVERVFS#3 WEST VAILProject Number - 18182399 NORTH FRONTAGE ROAD WESTVAIL, CO 8165701/10/2019 DRB OWNER: TOWN OF VAIL 1309 ELKHORN DRIVE VAIL, COLORADO 81657 ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE PIERCE ARCHITECTS 1650 E. VAIL VALLEY DRIVE, C1 VAIL, COLORADO 81657 P: 970.476.6342 F: 970.476.4901 E: bill@vailarchitects.com CONTRACTOR: P: M: E: STRUCTURAL ENGINEER: P: E: OWNER'S REP ADMINISTRATIVE INFO. BUILDING CODE SUMMARY PROJECT DIRECTORY BUILDING CODE: 2015 IBC CONSTRUCTION TYPE: TYPE V-A DWELLING UNITS: n/a OCCUPANCY TYPE S-1 LEGAL DESCRIPTION OF PROPERTY: Situs Address 2399 N FRONTAGE RD W VAIL, COLORADO Parcel Number 2103-114 -15-021 Tax Area: SC103 - VAIL (TOWN) - SC103 Legal Summary Subdivision:VAIL DAS SCHONE FIL 1 PARCEL A RESUB TRACT D BK-0217 PG-0177 GWD 02-20-70 R200634930 DEC 12-21-06 VFS #3 - BACK-UP GENERATOR ENCLOSURE 1" = 80'-0" PROJECT AREA DRB APPROVED 2/6/2019 12:00:00 AM EXISTING VFS #3 A4.01 1 Sim EXISTING SIDEWALK POSSIBLE LOCATION FOR REPLACEMENTTREES COULD SHIFT STRUCTURE WEST TO TRY AND PRESERVE TREES EXISTING TREES MAY NEED TO BE REPLACED NEW GENERATOR ENCLOSURE EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3 EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.10 AREA PLANVFS#3 WEST VAILProject Number - 18182399 NORTH FRONTAGE ROAD WESTVAIL, CO 8165701/10/2019 DRB    3/16" = 1'-0"1 GROUND FLOOR 1/16" = 1'-0" AREA PLAN Replacements trees are too close the existing building and new building. Site may not be adequate to install replacement trees. DRB APPROVED 2/6/2019 12:00:00 AM EXISTING VFS #3 A4.01 1 Sim EXISTING SIDEWALK COULD SHIFT STRUCTURE WEST TO TRY AND PRESERVE TREES EXISTING TREES MAY NEED TO BE REPLACED; RELOCATE IF POSSIBLE; 5" ASPEN X3 NEW GENERATOR ENCLOSURE EXISTING LAMP POST TO REMAIN; RELOCATE IF NECESSARY EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3 EXISTING SIDEWALK NEW GENERATOR ENCLOSURE EXISTING VFS #3 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.10 AREA PLANVFS#3 WEST VAILProject Number - 18182399 NORTH FRONTAGE ROAD WESTVAIL, CO 8165701/31/2019 DRB DATE NO. DESCRIPTION 3/16" = 1'-0"1 GROUND FLOOR 1/16" = 1'-0" AREA PLAN Applicants shall replace the three (3) aspen trees removed with three (3) new aspen trees with a minimum caliper of three inches (3"), which trees shall be located to the east of the generator enclosure. DRB APPROVED 2/6/2019 12:00:00 AM BB AA 1A 2A 2A 12'-7"3'-0" 9'-11"CLEARANCE FROM EXISTING6'-0" 4'-0"3'-5" 11 3/4" 1'-9 3/4" 9'-2 1/4" 2 A4.01 W8-1 1A 0A COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS BACK-UP GENERATOR KOHLER - MODEL 125REOZJD EXISTING VFS #3 NEW SIDEWALK TO CONNECT TO EXSITING SIDEWALK DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT W8-2 MAIN LEVEL 8179' - 0 1/2" 1A 2A 2 1/2" / 1'-0" 3'-0" 12'-7"9'-9 3/4"SPRING POINT7'-6"0A W8-1 W8-1 1A COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS BEYOND BACK-UP GENERATOR KOHLER - MODEL 125REOZJD ROOF SLOPE TO MATCH EXISTING BUILDING DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT 4" CONCRETE SLAB WITH THICKENED SLAB EDGE 5/8" GYPSUM WALL BOARD 8" W8-1 8" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. FILL CAVITY WITH RIGID INSULATION 1 1/2" HAT CHANNELS16" O.C.5/8" PLYWOOD SHEATHING TYVEK BUILDING WRAP CORTEN WALL PANELS TO MATCH EXISTING EXTERIORINTERIOR WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS NEW SIDEWALK TO CONNECT TO EXSITING SIDEWALK CORTEN METAL PANELS TO MATCH EXISTING EXISTING VFS #3 ROOF FORM TO MATCH SIMILAR AS EXISTING COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS NEW SIDEWALK TO CONNECT TO EXISTING SIDEWALK DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT EXISTING VFS #3 W8-2 8" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. FILL CAVITY WITH RIGID INSULATION 5/8" PLYWOOD SHEATHING TYVEK BUILDING WRAP CORTEN WALL PANELS TO MATCH EXISTING CORTEN WALL PANELS TO MATCH EXISTING TYVEK BUILDING WRAP 5/8" PLYWOOD SHEATHING 8" EXTERIOR EXTERIOR 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A4.01 ENLARGED GEN. ENCLOSUREVFS#3 WEST VAILProject Number - 18182399 NORTH FRONTAGE ROAD WESTVAIL, CO 8165701/04/2019 DRB 1/2" = 1'-0"1 GENERATOR ENCLOSURE - ENLARGED 1/2" = 1'-0"2 GENERATOR ENCLOSURE SECTION 3" = 1'-0"3 W8-1 8" METAL STUD WITH CORTEN PANELS 4 GENERATOR ENCLOSURE 3D 1 5 GENERATOR ENCLOSURE 3D 2 3" = 1'-0"6 W8-1 8" METAL STUD WITH CORTEN PANELS ON 2 SIDES DOOR SCHEDULE DOOR # DOOR STYLE LOCATION SIZE HARDWARE PACKAGE COMMENTS INTERIOR OR EXTERIORWIDTH HEIGHT 1A FLUSH PANEL, METAL GENERATOR ENCLOSURE 3' - 0" 6' - 8" TBD EXTERIOR PRECEDENT IMAGE WE TRIED TO MAKE THE ADDITION LOOK SIMILAR TO THIS EXISTING FORM.    Because this building will support equipment and power generation for emmergency services it is considered a Risk Catagory IV Building (IBC Table 1604.5) and therfore a 48 inch frost protected footer is req,d. IBC 1809.5 DRB APPROVED 2/6/2019 12:00:00 AM BB AA 1A 2A 2A 12'-7"3'-0" 9'-11"CLEARANCE FROM EXISTING6'-0" 4'-0"3'-5" 11 3/4" 1'-9 3/4" 9'-2 1/4" 2 A4.01 W8-1 1A 0A COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS BACK-UP GENERATOR KOHLER - MODEL 125REOZJD EXISTING VFS #3 NEW SIDEWALK TO CONNECT TO EXSITING SIDEWALK DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT W8-2 MAIN LEVEL 8179' - 0 1/2" 1A 2A 2 1/2" / 1'-0" 3'-0" 12'-7"9'-9 3/4"SPRING POINT7'-6"0A W8-1 W8-1 1A COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS BEYOND BACK-UP GENERATOR KOHLER - MODEL 125REOZJD ROOF SLOPE TO MATCH EXISTING BUILDING DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT CONCRETE SLAB AND HELICAL PIERS OR OTHER SYSTEM PER STRUCTURAL; 48" DEEP FOR FROST PROTECTION 5/8" GYPSUM WALL BOARD 8" W8-1 8" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. FILL CAVITY WITH RIGID INSULATION 1 1/2" HAT CHANNELS16" O.C.5/8" PLYWOOD SHEATHING TYVEK BUILDING WRAP CORTEN WALL PANELS TO MATCH EXISTING EXTERIORINTERIOR WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS NEW SIDEWALK TO CONNECT TO EXSITING SIDEWALK CORTEN METAL PANELS TO MATCH EXISTING EXISTING VFS #3; TAN HORIZONTAL SIDING ROOF FORM TO MATCH SIMILAR AS EXISTING; SHEET METAL ROOFING 1A COOLING AND EXHAUST VENTILATION VIA LOUVERED EXHAUST FAN WALL EXTENSION TO SHIELD SOUND FROM NEIGHBORS NEW SIDEWALK TO CONNECT TO EXISTING SIDEWALK DOOR COULD OUTSWING TO REDUCE ENCLOSURE FOOTPRINT EXISTING VFS #3; TAN HORIZONTAL SIDING 1A W8-2 8" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. FILL CAVITY WITH RIGID INSULATION 5/8" PLYWOOD SHEATHING TYVEK BUILDING WRAP CORTEN WALL PANELS TO MATCH EXISTING CORTEN WALL PANELS TO MATCH EXISTING TYVEK BUILDING WRAP 5/8" PLYWOOD SHEATHING 8" EXTERIOR EXTERIOR 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A4.01 ENLARGED GEN. ENCLOSUREVFS#3 WEST VAILProject Number - 18182399 NORTH FRONTAGE ROAD WESTVAIL, CO 8165701/31/2019 DRB 1/2" = 1'-0"1 GENERATOR ENCLOSURE -ENLARGED 1/2" = 1'-0"2 GENERATOR ENCLOSURE SECTION 3" = 1'-0"3 W8-1 8" METAL STUD WITH CORTEN PANELS 4 GENERATOR ENCLOSURE 3D 1 5 GENERATOR ENCLOSURE 3D 2 3" = 1'-0"6 W8-1 8" METAL STUD WITH CORTEN PANELS ON 2 SIDES DOOR SCHEDULE DOOR # DOOR STYLE LOCATION SIZE HARDWARE PACKAGE COMMENTS INTERIOR OR EXTERIORWIDTH HEIGHT 1A FLUSH PANEL, METAL GENERATOR ENCLOSURE 3' - 0" 6' - 8" TBD EXTERIOR 2A FLUSH PANEL, WOOD UPPER LEVEL - IT ROOM 3' - 0" 6' - 8" TBD INTERIOR 2B FLUSH PANEL, WOODUPPER LEVEL - OFFICE HALLWAY 2' - 8" 6' - 8" TBD INTERIOR 2C FLUSH PANEL, WOOD UPPER LEVEL - LAUNDRY 2' - 8" 6' - 8" TBD INTERIOR PRECEDENT IMAGE WE TRIED TO MAKE THE ADDITION LOOK SIMILAR TO THIS EXISTING FORM. DATE NO. DESCRIPTION *NO ADDITIONAL OUTDOOR LIGHTING PROPOSED DRB APPROVED 2/6/2019 12:00:00 AM