Loading...
HomeMy WebLinkAboutPEC19-0002_approved plans_1550008159.pdfREFREF REFUP 2 2.3 3 3.2 3.53.7 4 4.4 5 5.4 6 7 8 9 9.69.7 10 10.5 10.6 1111.211.311.411.6 1212.1 12.512.6 13 13.7 14 15 16 16.6 16.917 17.8182.7 3.3 4.2 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A4.6 A9.9 D2 D1 DA CB CA C1 C2 C3 B1 B2 B3 B4 B5 B6 B7 B5.8 B6.4 BE BD BC BB BA A12.2 EA E1 E2 B4.3 A8.2 A18 1 2 2.3 3 3.2 3.5 3.7 4 4.4 5 5.4 6 7 8 9 9.69.7 10 10.5 10.6 1111.211.311.411.6 1212.1 12.512.6 13 13.7 14 15 16 16.6 16.917 17.8182.7 3.3 4.2 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A4.6 A5.3 A9.9 A15.3 A16.1 A16.6 D2 D1 DA CB CA C1 C2 C3 B1 B2 B3 B4 B5 B6 B7 B5.8 B6.4 BE BD BC BB BA A12.2 EA E1 E2 B4.3 A8.2 KITCHEN GALLERY GALLERY RESID. CLUB LOBBY RESID CLUB CORRIDOR SITTING NICHE ENTRY FOYERSITTING NICHE KITCHEN STAIR "U" ELEV. LOBBY RESID. CLUB CONCIERGE DESK VESTIBULE REMEDY BAR PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 11:19:09 AM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvt 1/16" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL OVERALL LEVEL 5 FLOOR PLAN A-000 FOUR SEASONS RESORT AT VAIL OZ PROJECT FLAGNOTES NO. FLAGNOTE 1/16" = 1'-0"1 LEVEL 5 - OVERALL PLAN 0' 8' 16' 32' 64' 109 SF NEW ADDITION PROPOSED LOUVER LOCATION PROPOSED KITCHEN EXPANSION PEC APPROVED 2/12/2019 12:00:00 AM 12'-5 1_4"1'-8 5_ 8" 6'-9" 6'-53_ 8" 1_ 4" 61_ 8 2'-9 1_ 4" 7 1_"06-08-2007FEC 4.4 A4.6 4 5 5.4 6 74.2 A2 A3 A4 A5 A6 A7 A8 A9 A10 A4.6 A5.3 A9.9 A8.2 2.03 2.04 NEW KITCHEN AREA NORTH ENTRANCE NEW RESID. CLUB HALLWAY SITTING NICHE GALLERY ENTRY FOYER REMEDY BAR RESID. CLUB LOBBY ELEV. LOBBY KITCHEN STAIR "U" VESTIBULE RESID. CLUB CONCIERGE DESK SKI/GOLF BAG STORAGE 6' - 0"6' - 0" 2.08 KEY PLAN SCOPE OF WORK IN SCOPE OF CONTRACT NOT IN SCOPE OF CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 12:00:04 PM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL DEMO PLAN A-001 FOUR SEASONS RESORT AT VAIL OZ PROJECT FLAGNOTES NO. FLAGNOTE 2.03 DEMO (E) SPEAKER AND SALVAGE FOR OWNER REUSE. 2.04 DEMO (E) EXIT SIGN 2.08 DEMO (E) FEC AND SALVAGE FOR REUSE 1/4" = 1'-0"1 LEVEL 5 - REMEDY KITCHEN - DEMO PLAN 0' 8' 16' 32' 64' DEMOLITION PLAN NOTES 1 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 3 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 4 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 5 SEE REFLECTED CEILING PLANS FOR CEILING DEMOLITION WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. PEC APPROVED 2/12/2019 12:00:00 AM B A A A A A A A A A A A A A A TTT (2)K.2 AA A A B B B A A A A A ENTRY - VESTIBULE - GALLERY WEST - LOUNGE - BAR - 41_ 4 41_441_ 44 1_"441_ 4 41_447_ 841_441_ 4 41_441_ 4 41_ 4 47 8 10 10 1_43_ 441_444 41_44 7_ "687 41_434"4.4 A4.6 A5.3 4 5 5.4 6 74.2 A2 A3 A4 A5 A6 A7 A8 A9 A10 A4.6 A5.3 A9.9 A8.2 ENTRY FOYER GALLERY REMEDY BAR KITCHEN STAIR "U" RESID. CLUB LOBBY VESTIBULE SKI/GOLF BAG STORAGE RESID. CLUB CONCIERGE DESK 2.07 place keynotes for 1- remove lighting fixtures salvage for owner 2- demo ceiling finish 3- remove speaker from the wall and salvage for owner 2.10 2.11 26.06 2.09 8' - 0" 7' - 11" 9' - 0" 8' - 0" 8' - 0" 8' - 3" 2.20 KEY PLAN CEILING PLAN LEGEND GYP. BOARD ACT-01 ACT-02 NOT IN SCOPE SCOPE OF WORK IN SCOPE OF CONTRACT NOT IN SCOPE OF CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 12:00:11 PM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL DEMO REFLECTED CEILING PLAN A-031 FOUR SEASONS RESORT AT VAIL OZ 1/4" = 1'-0"1 LEVEL 5 - REMEDY KITCHEN - DEMO REFLECTED CEILING PLAN 0' 8' 16' 32' 64' DEMOLITION PLAN NOTES 1 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 3 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 4 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 5 SEE REFLECTED CEILING PLANS FOR CEILING DEMOLITION WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. PROJECT FLAGNOTES NO. FLAGNOTE 2.07 DEMO (E) TONGUE AND GROOVE CEILING FINISH 2.09 COORD (E) ACCESS HATCH TO BE RELOCATED 2.10 DEMO (E) LIGHT FIXTURE AND SALVAGE FOR OWNER 2.11 DEMO CEILING, SALVAGE WOOD BEAMS AND TRIM FOR REUSE PER OWNER. 2.20 DEMO 36"X36" OPENING FOR MAU, RE MEP 26.06 GC TO COORD. LOCATION OF SPEAKERS WITH ARCH PEC APPROVED 2/12/2019 12:00:00 AM 4.4 A4.6 4 5 5.4 6 74.2 A2 A3 A4 A5 A6 A7 A8 A9 A10 A4.6 A5.3 A9.9 A8.2 REMEDY BAR 509 STAIR "U" S-519 KITCHEN 510 ELEV. LOBBY E-501 RESID. CLUB LOBBY 511 VESTIBULE 514 RESID. CLUB CONCIERGE DESK 512 RESID CLUB CORRIDOR 504 SITTING NICHE 502 ENTRY FOYER 501 GALLERY 505 KITCHEN 14 3" 26 23 ALIGN ALIGN 3' - 0"5' - 9 7/8"ALIGN2' - 0" 5' - 10 1/2" 001- 33 8' - 10 1/4" 2' - 8 1/2" ALIGN5' - 8"ALIGN 1' - 6" 1' - 11"1' - 3"14' - 0" 4' - 1"2' - 0"1' - 7 1/2"1' - 7 1/2" 110- 17KEY PLAN SCOPE OF WORK IN SCOPE OF CONTRACT NOT IN SCOPE OF CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 12:00:17 PM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL FLOOR PLAN A-101 FOUR SEASONS RESORT AT VAIL OZ 1/4" = 1'-0"1 LEVEL 5 - REMEDY KITCHEN - FLOOR PLAN 0' 8' 16' 32' 64' FLOOR PLAN NOTES 1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF ______. 2EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O. 3INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 4SEE SHEET G-503 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIES SHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE 23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O. 5PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O. 6MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES. 7WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O. 8WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION. 9WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC CHAPTER 7. 10PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION. 11THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSED CONSTRUCTION. 12FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND OTHER BUILT-IN ITEMS. 13SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTURE GRAB BARS. 14SEE SHEET A-600 FOR DOOR SCHEDULE. 15SEE A-700 SERIES SHEETS FOR UNIT PLANS. PROJECT FLAGNOTES NO. FLAGNOTE Area check: 127.4 sf (good) SDD Non-Res Floor Area (from SDD #36 ordinance) = 38,048sf 109 sf / 38048 sf = 0.3% (< 5%, minor amendment) PEC APPROVED 2/12/2019 12:00:00 AM B A A A A A A A A A A A A A A TTT (2)K.2 AA A A B B B A A A A A CEILING PLAN LEGEND GYP. BOARD ACT-01 ACT-02 NOT IN SCOPE 4.4 4 5 5.4 6 74.2 A2 A3 A4 A5 A6 A7 A8 A9 A10 A4.6 A5.3 A9.9 A8.2 REMEDY BAR GALLERY SITTING NICHE ENTRY FOYER RESID CLUB CORRIDOR RESID. CLUB LOBBY VESTIBULE ELEV. LOBBY STAIR "U" KITCHEN KITCHEN 8' - 0" 9' - 4" 8' - 0" 23.01 9' - 0" KEY PLAN SCOPE OF WORK IN SCOPE OF CONTRACT NOT IN SCOPE OF CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 12:00:23 PM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL REFLECTED CEILING PLAN A-131 FOUR SEASONS RESORT AT VAIL OZ PROJECT FLAGNOTES NO. FLAGNOTE 23.01 NEW MAKE UP AIR UNIT (MAU) EXHAUST LOUVER, RE: MEP 1/4" = 1'-0"1 LEVEL 5 - REMEDY KITCHEN - REFLECTED CEILING PLAN 0' 8' 16' 32' 64' REFLECTED CEILING PLAN NOTES 1 REFLECTED CEILING PLANS INDICATE CEILING HEIGHTS AND LOCATION OF LIGHT FIXTURES, DIFFUSERS, DEVICES, AND SIMILAR ITEMS. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL, HVAC, SPRINKLER AND LIFE SAFETY. IN THE EVENT OF A DISCREPANCY BETWEEN THE ARCHITECT'S REFLECTED CEILING PLAN AND THE ENGINEERS' PLANS, SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCE FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC. NECESSARY TO MAINTAIN THE CEILING HEIGHTS INDICATED. 3 DIMENSIONS ARE TO FINISH U.N.O. 4 ACCESS PANELS NOT SHOWN, BUT REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS, SHALL BE REVIEWED WITH ARCHITECT FOR LOCATION. 5.COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ARCHITECT. 6 LIGHT FIXTURES, SPRINKLER HEADS, AND OTHER CEILING DEVICES SHALL BE EQUALLY SPACED AND ALIGNED WITH ADJACENT ELEMENTS AND CENTERED ON CEILING TILE, U.N.O. 7 CENTER ACOUSTICAL CEILING GRID WITHIN THE ROOM U.N.O. 8 PAINT GYPSUM BOARD CEILINGS P__ U.N.O. 9 PAINT GYP BOARD SOFFITS (VERTICAL AND HORIZONTAL SURFACES) P__ U.N.O. 10PAINT EXPOSED CEILING STRUCTURE AND DUCTWORK P__ U.N.O. 11PROVIDE UL-CLASSIFIED LIGHT FIXTURES OR ENCLOSURES IN RATED FLOOR/CEILING ASSEMBLIES IN ACCORDANCE WITH IBC CHAPTER 7. PEC APPROVED 2/12/2019 12:00:00 AM PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 10:47:00 AM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_skovats.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL BUILDING ELEVATIONS A-201 FOUR SEASONS RESORT AT VAIL OZ 1/16" = 1'-0"1 NORTH ELEVATION PROPOSED 1/4" = 1'-0"2 NORTH ELEVATION EXISTING PEC APPROVED 2/12/2019 12:00:00 AM OWNER EX VAIL LLC EXTELL DEVELOPMENT COMPANY 805 THIRD AVENUE NEW YORK, NY 10022 VOICE: 212.712.6000 MEP BG BUILDINGWORKS 1626 COLE BOULEVARD BUILDING 7 - SUITE 300 LAKEWOOD, CO 80401 VOICE: 303.278.3820 ARCHITECT OZ ARCHITECTURE 3003 LARIMER STREET DENVER, CO 80205 VOICE: 303.861.5704 KITCHEN CONSULTANT JEDRZIEWSKI DESIGNS 1537 EAST YALE AVENUE CITY, STATE, ZIP VOICE: 801.582.9747 CONTRACTOR THE KORTE COMPANY 12441 U.S. HIGHWAY 40 HIGHLAND, IL 62249 VOICE: 618.654.8611 INTERIOR DESIGNER JEFFREY BEERS INTERNATIONAL, LLC 156 FIFTH AVENUE, PENTHOUSE II NEW YORK, NY 10010 VOICE: 212.352.2020 EXT. 313 PROJECT LOCATION APPLICABLE CODES: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2017 ICC/ANSI A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2018 NATIONAL ELECTRICAL CODE (NEC) TOWN OF VAIL LOCAL AMENDMENTS BUILDING OCCUPANCY CLASSIFICATION: R-1 CONSTRUCTION TYPE: TYPE 1-B FIRE RESISTIVE FIRE SUPRESSION: FULLY SPRINKLERED PER NFPA 13 (EXISTING TO REMAIN). KEY PLAN PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 10:47:01 AM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_skovats.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL COVER G-000 FOUR SEASONS RESORT AT VAIL OZ ABBREVIATIONS GENERAL NOTES GRAPHIC STANDARDS PROJECT TEAM VICINITY MAP DRAWING INDEX FOUR SEASONS RESORT AT VAIL PEC SUBMITTAL 2019/01/28 ONE VAIL ROAD VAIL, CO 81657 TRUE NORTH MATL MATERIAL MAX MAXIMUM MB MOISTURE BARRIER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MM MILLIMETERS MO MASONRY OPENING MTD MOUNT(ED) MTL METAL MUL MULLION (N) NEW N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OTO OUTSIDE-TO-OUTSIDE P PAINT(ED) P/L PROPERTY LINE PAC PREVIOUSLY AWARDED CONTRACT PAR PARALLEL PBO PROVIDED BY OTHERS PC PRECAST PERF PERFORATED PERIM PERIMETER PKG PARKING PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNL PANEL POL POLISHED PR PAIR or PROPOSAL REQUEST PREFAB PREFABRICATED PREFIN PREFINISHED PRESTR PRESTRESSED PRIM PRIMARY PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PT POINT OF TANGENCY PTD PAPER TOWEL DISPENSER PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R) REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED) RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S) RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE) RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S) SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL or SOLID SURFACE SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UOS UNLESS OTHERWISE SPECIFIED UR. URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O. WHERE OCCURS W/ WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF. WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING) WPT WORKING POINT WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YD YARD # POUND(S) or NUMBER & AND < ANGLE @ AT A/V AUDIO/VISUAL AB ANCHOR BOLT ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE AD AREA DRAIN or ACCESS DOOR ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AUTO AUTOMATIC AVE AVENUE AVG AVERAGE AWP ACOUSTICAL WALL PANEL B BASE B.O. BY OWNER B.O.F. BY OWNER, FUTURE BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT C CAULKING C.L. CENTERLINE CAB CABINET CATV CABLE TELEVISION CCD CONSTRUCTION CHANGE DIRECTIVE CCTV CLOSED CIRCUIT TELEVISION CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CFL COUNTERFLASHING CG CORNER GUARD CIP CAST IN PLACE CIRC CIRCUMFERENCE CJ CONTROL JOINT CK CORK TILE CL COLUMN LINE CLG CEILING CLOS CLOSET CLR CLEAR CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CT CERAMIC TILE CTR COUNTER CU CUBIC CY CUBIC YARD DAMP DAMPROOFING DBL DOUBLE DEG DEGREE DEMO DEMOLISH or DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DS DOWNSPOUT DTL DETAIL DWG DRAWING DWR DRAWER (E) EXISTING E EAST EA EACH EB EXPANSION BOLT ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EST ESTIMATE EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR F FARENHEIT FA FIRE ALARM FAC FIRE ALARM CABINET FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S) FD FLOOR DRAIN or FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFL FINISHED FLOOR LINE FH FIRE HYDRANT FHC FIRE HOSE CABINET FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FHWS FLAT HEAD WOOD SCREW FIN FINISH(ED) FIXT FIXTURE FLG FLASHING FLR FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RESISTIVE or FIRE RATED FRP FIBERGLASS REINFORCED PANEL(ING) FRT FIRE RETARDANT TREATED FT FOOT (FEET) FTG FOOTING FURN FURNISH(ED) FURR FURRED or FURRING FUT FUTURE FVC FIRE VALVE CABINET GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT(S) GI GALVANIZED IRON GL GLASS or GLAZING GND GROUND GR GRADE GRT GROUT GT GLASS TILE GWB GYPSUM WALLBOARD GYP GYPSUM GYP. BD. GYPSUM BOARD HAS HEADED ANCHOR STUD HB HOSE BIB HC HOLLOW CORE or HANDICAPPED HDAS HEADED DEFORMED ANCHOR STUD HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HTR HEATER HVAC HEATING, VENTILATION and AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR ID INSIDE DIAMETER IN INCH(ES) INCAND INCANDESCENT INCL INCLUD(ED) INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INTMED INTERMEDIATE INV INVERT JC JANITOR CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIT KITCHEN KO KNOCKOUT KP KICK PLATE LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LDR LEADER LH LEFT HAND LKR LOCKER LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL or LIGHT PROOF LT LIGHT LTL LINTEL LVR LOUVER MACH MACHINERY MAG MAGNETIC MAS MASONRY Sheet Number Sheet Name GENERAL G-000 COVER G-101 CODE PLAN AND SCHEDULES ARCHITECTURE A-000 OVERALL LEVEL 5 FLOOR PLAN A-001 DEMO PLAN A-031 DEMO REFLECTED CEILING PLAN A-101 FLOOR PLAN A-131 REFLECTED CEILING PLAN A-201 BUILDING ELEVATIONS A-301 BUILDING SECTIONS A-501 DETAILS A-551 INTERIOR DETAILS & ELEVATIONS A-601 WINDOW & DOOR SCHEDULE, TYPES & DETAILS LEGAL DESCRIPTION: Vail Village Filing 2 Lot: A-C Parcel #: 210107122001 PEC APPROVED 2/12/2019 12:00:00 AM PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 11:42:44 AM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL EXISTING SITE PLAN G-100 FOUR SEASONS RESORT AT VAIL OZ 1/8" = 1'-0" 1 EXISTING SITE PLAN PEC APPROVED 2/12/2019 12:00:00 AM PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®1/28/2019 11:42:08 AM C:\Revit Local Files\116194.00_FSV_A19_RemedyKitchen_Central_jpate.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2019/01/28 PEC SUBMITTAL PROPOSED SITE PLAN G-101 FOUR SEASONS RESORT AT VAIL OZ 1/8" = 1'-0"1 PROPOSED SITE PLAN PEC APPROVED 2/12/2019 12:00:00 AM