Loading...
HomeMy WebLinkAbout2016-01-05 Agenda and Supporting Documentation Town Council Regular MeetingNOTE: 2. 0 4. VAIL TOWN COUNCIL 0� REGULAR MEETING AGENDA TVWN OF VA10 VAIL TOWN COUNCIL CHAMBERS 75 S. Frontage Road W. Vail, CO 81657 1:00 P.M., JANUARY 5, 2016 Times of items are approximate, subject to change, and cannot be relied upon to determine at what time Council will consider an item. ITEM/TOPIC: Site Visit to Simba Run A site visit to the location of proposed de -humidifier which is subject to the appeal being heard during the January 5, 2016 Regular Town Council Meeting. (30 min.) PRESENTER(S): Jonathan Spence, Planner ITEM/TOPIC: PEC/DRB Update (5 min.) PRESENTER(S): Chris Neubecker, Planning Manager ITEM/TOPIC: Review Residential Sprinkler Requirements from currently adopted Codes (30 min. ) PRESENTER(S): Mark Novak, Fire Chief, Mike Vaughan, Fire Marshal ACTION REQUESTED OF COUNCIL: No action on this topic is requested at this time. BACKGROUND: Town Council has requested more information on the threshold requirements that trigger a fire sprinkler retrofit during residential renovation projects. ITEM/TOPIC: Discussion of various Funding Options for the Chamonix housing development. (30 min.) PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the various options and provide staff guidance on next steps in selecting a preferred funding alternative, and provide feedback on the following: . What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? . What is the Town Council's tolerance for financial risk and desired level of investment? BACKGROUND: Funding is a critical consideration prior to moving 1/5/2016 forward with this housing development. The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the funding options to pursue. That decision point will need to occur in this first quarter of 2016. 5. ITEMITOPIC: Discussion of Pricing Strategy Options for the Chamonix housing development. (30 min.) PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the alternative pricing strategies for the Chamonix Development and provide direction on next steps, and provide feedback on the following: . What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? . What range of income diversity does Town Council want to include in the development? . What is the Town Council's level of comfort in subsidizing the Chamonix development? BACKGROUND: The Town has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the pricing strategy. That decision point will need to occur before the end of the first quarter of 2016. 6. ITEM/TOPIC: Discussion of the various Subsidy Options to consider for the Chamonix housing development. (30 min.) PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the alternative subsidy policies for the Chamonix Development and provide direction on next steps, and provide feedback on the following: . What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? . What level of Income diversity does Town Council want to include in the development? What levels of subsidy is Town Council willing to consider? BACKGROUND: Real estate in the Town of Vail remains largely out of the purchasing power for most employees earning their income in Eagle County. To increase the affordable housing opportunities for employees living in town, the Vail Town Council has purchased and master planned what is commonly referred to as the Chamonix Development for deed restricted employee housing. The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the Subsidy Policies. That decision point will need to occur before the end 1/5/2016 of the first quarter of 2016. 7. ITEMITOPIC: Information Update: 1) November Sales Tax Report 2) Revenue Highlights 3) Random Acts of Kindness Program (5 min.) 8. ITEM/TOPIC: Matters from Mayor, Council and Committee Reports (10 min.) 9. ITEMITOPIC: Executive Session, pursuant to: 1) C.R.S. §24-6-402 (4)(a)(b)(e) - to discuss the purchase, acquisition, lease, transfer, or sale of property interests; to receive legal advice on specific legal questions; and to determine positions, develop a strategy and instruct negotiators, Regarding: City Market Land Lease (15 min.) PRESENTER(S): Matt Mire, Town Attorney 10. ITEMITOPIC: Council will recess the meeting until 6:00 pm 11. ITEMITOPIC: Citizen Participation begins at 6:00 pm (5 min.) 12. ITEM/TOPIC: Consent Agenda 1) Minutes from December 1, 2015 meeting 2) Minutes from December 15, 2015 meeting 3) Resolution No. 1, Series of 2016, a Resolution Approving the Amendment to the Development Agreement Between the Town of Vail and Lion's Ridge Apartment Homes, LLC; and Setting Forth Details in Regard Thereto (5 min.) 13. ITEMITOPIC: Town Manager's Report: 1) Summit County Tour of Affordable Housing Properties and Special Council Meeting to discuss Chamonix Housing Project set for January 12, 2016 at 6 pm. (5 min. ) PRESENTER(S): Stan Zemler, Town Manager 14. ITEMITOPIC: An appeal, pursuant to Section 12-3-3, Appeals, Vail Town Code, of the final decision of the Town of Vail Design Review Board on October 21, 2015, approving a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6- 10, Block C, Lion's Ridge Subdivision, and setting forth details in regard thereto. (DRB150454) (30 min.) PRESENTER(S): Jonathan Spence, Planner ACTION REQUESTED OF COUNCIL: The question to be answered by the Vail Town Council regarding this appeal is: Were the requirements of the Vail Town Code, specifically Title 14, Chapter 10, Design Review Standards and Guidelines properly applied in the decision to allow for an exterior alteration for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West? Pursuant to Section 12-3-3, Appeals, Vail Town Code, the Vail Town 1/5/2016 Council shall uphold, uphold with modifications, or overturn the Design Review Board's October 21, 2015, decision. BACKGROUND: On September 16, 2015, the Design Review Board (DRB) reviewed a conceptual plan (DRB150388) for the installation of a dehumidifier, associated condenser and screen wall at the Simba Run Condominiums. A component of this conceptual review was a site visit to the subject property. On October 10, 2015, the Community Development Department, upon the direction from the DRB, approved an Exterior Alteration application (DRB150454), with no conditions, for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums. This decision became final on October 21, 2015 when the DRB affirmed this approval during the scheduled public hearing. On October 22, 2015, the Town of Vail Community Development Department received an appeal from Mr. Robert W. Kleinman, Owner, Simba Run Condominium Unit 2310 with regard to the Design Review Board's action to approve the aforementioned exterior alteration. STAFF RECOMMENDATION: Should the Vail Town Council choose to uphold the determination of the Town of Vail Design Review Board, the following statement is recommended: "The Vail Town Council finds as follows: The Vail Town Code was properly applied in regard to the October 21, 2015 Design Review Board approval of DRB150454. Furthermore, the project consisting of a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6- 10, Block C, Lion's Ridge Subdivision, is consistent with Title 14, Development Standards, of the Vail Town Code." 15. ITEMITOPIC: Resolution No. 38, Series of 2015, a resolution amending the Lionshead Redevelopment Master Plan to amend detailed plan recommendations for future development on the Evergreen at Vail development site, as prescribed in Chapter 5 of the Lionshead Redevelopment Master Plan, and setting forth details in regard thereto. (30 min) PRESENTER(S): George Ruther, Director of Community Development ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny the resolution as presented. BACKGROUND: The applicant, Evergreen Lodge at Vail, represented by the Mauriello Planning Group, is requesting a public hearing with the Vail Town Council to present recommended amendments to Chapter 5, Detailed Plan Recommendations, subsection 5.19, Evergreen Lodge at Vail, of the Lionshead Redevelopment Master Plan. The four purposes of the amendments are to: 1. Clearly identify and articulate the desired outcomes of a future redevelopment of the Evergreen Lodge at Vail property, 2. Remove language from the Master Plan which is no longer relevant or applicable, 3. Respond to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establish predictability within the review process by providing detailed site specific recommendations for redevelopment of the Evergreen Lodge at Vail site. The requested amendments are as reflected in Resolution No. 38, Series of 2015. 1/5/2016 16. 17 STAFF RECOMMENDATION: The Town of Vail Planning and Environmental Commission has forwarded a unanimous recommendation of approval of the requested amendments to the Vail Town Council. Based upon the input provided during the public hearings on this item on December 1 and December 15, 2015, the Community Development Department recommends the amendments and revisions made as reflected in Resolution No. 38, Series of 2015. ITEM/TOPIC: First reading of Ordinance No. 1, Series of 2016, An Ordinance Amending the Definition of Short -Term Rental in the Vail Town Code (5 min. ) PRESENTER(S): Matt Mire, Town Attorney ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny Ordinance No. 1, Series of 2016, upon first reading. BACKGROUND: Section 12-2-2 of the Vail Town Code defines a short-term rental as a rental for a period of time not exceeding 31 days. Section 4-1-2 of the Vail Town Code defines short-term rental as a rental for a period of time not exceeding 30 days. The Town Council desires to amend Section 12-2-2 to ensure consistency in the Vail Town Code. STAFF RECOMMENDATION: Approve, approve with modifications, or deny Ordinance No. 1, Series of 2016, upon first reading. ITEM/TOPIC: First reading of Ordinance No. 2, Series of 2016. An Ordinance Amending Title 12, Zoning Regulations, Vail Town Code, Pursuant to Section 12-3-7, Amendment, Vail Town Code, to allow for Religious Institutions as a Conditional Use in all zone districts except the Heavy Service (HS) District; Outdoor Recreation (OR); Natural Area Preservation (NAP); Hillside Residential (HR); Single Family Residential (SFR); Two -Family Residential (R) ; Two -Family Primary/Secondary (PS); Housing (H); Vail Village Townhomes (VVT); and Arterial Business (ABD); amending the definition of Religious Institutions, and setting forth details in regard thereto. (15 min.) PRESENTER(S): Chris Neubecker, Planning Manager ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny Ordinance No. 2, Series of 2016, upon first reading. BACKGROUND: In September 2015, the Community Development Department was approached by a citizen concerning the lack of zoning districts that allow Religious Institutions. After considering the application, and also considering applicable federal laws, the Department determined that this issue extends beyond the commercial zone districts and needed greater consideration. This ordinance will also bring the Town's Zoning Regulations into greater conformance with the Religious Land Use and Institutionalized Persons Act (RLUIPA). STAFF RECOMMENDATION: Approve or approve with 1/5/2016 modifications, Ordinance No. 2, Series of 2016, upon first reading. 18. ITEM/TOPIC: East Vail Fire Station Renovation, Budget and Design Update (20 min. ) PRESENTER(S): Mark Novak, Fire Chief, John King, Facilities Manager ACTION REQUESTED OF COUNCIL: 1) Direct staff to include in the first Supplemental of 2016 , an increase in the project budget of $750,000 as well as a separate supplement of $435,000 for completion of two EHUs. 2) Authorize the Town Manager to enter into an agreement with Pierce Architects to complete the design work, resulting in complete construction documents. BACKGROUND: In August 2015 Council authorized the Town Manager to enter into an agreement with Pierce Architects to complete Conceptual and Schematic design for the for the renovation of the East Vail Fire Station. This phase of the design has been completed and has resulted in an updated budget for the project. To move forward with the project, Council will need to direct staff to supplement the project budget in the March 2016 Supplemental and direct the Town Manager to enter into an agreement with Pierce Architects to complete the design work, resulting in complete construction documents 19. ITEM/TOPIC: Adjournment (7:55 p.m.) NOTE: UPCOMING MEETING TOPICS AND ESTIMATED TIMEFRAMES BELOW (ALL ARE APPROXIMATE DATES AND TIMES AND SUBJECT TO CHANGE) THE NEXT REGULAR VAIL TOWN COUNCIL MEETING WORK SESSION WILL BEGIN AT APPROXIMATELY 12:30 P.M. (or TBD), TUESDAY, JANUARY 19, 2016 IN THE VAIL TOWN COUNCIL CHAMBERS. Ongoing agenda items DRB/PEC updates WS - 15 min.; Information Updates Attachments: WS - 15 min.; Executive Session items: 30 min.; Consent Agenda: 5 min.; Town Manager Report: 5 min. Future agenda items: Summit County Housing Tour - 1/12 Special Meeting for Housing Discussion -TBD Review Matrix on Multi -Use Facilities - TBD Vail Municipal Building Remodel Update - TBD Cleanup Title 12, zoning amendments- TBD Gore Creek Water Quality Plan Update - TBD Vail Trails Update - TBD Environmental Strategic Plan Update - TBD Eagle County School District Meeting w/ Board - TBD Ford Park Leases - TBD Peer City Visit to Aspen - TBD Open Lands Strategic Plan - TBD Pedestrian Crossings at Roundabouts & Bus Shelters Discussion - TBD VRD Agreement for Skate Park - TBD 1/5/2016 Please call (970) 479-2138 for additional information. Sign language interpretation is available upon request with 48-hour notification. Please call (970) 479-2356, Telecommunication Device for the Deaf (TDD), for information. 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Site Visit to Simba Run A site visit to the location of proposed de -humidifier which is subject to the appeal being heard during the January 5, 2016 Regular Town Council Meeting. PRESENTER(S): Jonathan Spence, Planner 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: PEC/DRB Update PRESENTER(S): Chris Neubecker, Planning Manager ATTACHMENTS: December 16, 2015 DRB Meeting Results December 28, 2015 PEC Meeting Results 1/5/2016 rowN of va MEMBERS PRESENT Peter Cope Doug Cahill Bill Pierce Rollie Kjesbo Andy Forstl DESIGN REVIEW BOARD AGENDA PUBLIC MEETING December 16, 2015 Council Chambers 75 South Frontage Road West - Vail, Colorado, 81657 PROJECT ORIENTATION SITE VISITS MEMBERS ABSENT 1. Rionda Residence — 384 Gore Creek Drive 2. Burger Residence & 716 VailCO LLC Residence — 716 Forest Road MAIN AGENDA Breakaway West DRB 150548 Final review of an exterior alteration (fa(;ade) 963 Lions Ridge Loop, Buildings 100 and 200/Lot B3, Block B, Lions Ridge Filing Applicant: Breakaway West HOA, represented by Pierce Architecture ACTION: Table to January 6, 2016 2:OOpm 3:OOpm Jonathan MOTION: Forstl SECOND: Cope VOTE: 3-0-2 (Pierce and Kjesbo recused) 2. Holm Residence DRB150538 Chris Final review of new construction (Single Family Residence) 738 Sandy Lane/Lot 5, Vail Potato Patch Filing 2 Applicant: Claes & Amy Holm, represented by Krueger Architecture & Design ACTION: Approve with Conditions MOTION: Forstl SECOND: Cope VOTE: 5-0-0 CONDITION(S): Applicant shall submit a revised landscaping plan to the Community Development Department which shall include six (6) additional conifer trees between eight feet (8') and fourteen feet (14') tall on the north side of the home; two (2) additional conifer trees on the east side of the home; and ten (10) additional aspen trees (minimum of 2'/2 inch caliper), for a total of 18 additional trees. 3. Rionda Residence DRB150542 Conceptual review of an addition (dormer) 384 Gore Creek Drive, Unit 10 (Villa Valhalla)/Lot J, Block 5A, Vail Village Filing 5 Applicant: Jose Pedro Rionda, represented by Pierce Architects ACTION: N/A 4. Burger Residence DRB150544 Conceptual review of an addition 716A Forest Road/Lot 10, Block 1, Vail Village Filing 6 Applicant: Alexander & Amy Burger, represented by Pierce Architects Page 1 Jonathan Jonathan 1/5/2016 ACTION: N/A 5. 716 VailCO LLC Residence DRB150545 Conceptual review of an addition 716B Forest Road/Lot 10, Block 1, Vail Village Filing 6 Applicant: 716 VailCO LLC, represented by Pierce Architects ACTION: N/A Note: DRB Member Pierce recused himself from items 1, 3, 4 and 5. STAFF APPROVALS Ganz Residence OTC15-0068 Final review of an exterior alteration (doors) 4511 Meadow Drive Unit 704/Timber Falls Condominiums Applicant: Beth Ganz, represented by Eagle County Contractors Jonathan J. R. Harmon Residence DRB150541 Jonathan Final review of changes to approved plans (wetlands) 4284 Columbine Drive/Lot B, Bighorn Subdivision Applicant: Jeremy & Julie Harmon, represented by KH Webb Architects Cornide Residence DRB150546 Chris Final review of a change to approved plans (windows) 332 Beaver Dam Circle/Lot 6, Block 3, Vail Village Filing 3 Applicant: Jose Cornide, represented by Krueger Architecture Fisher 7131 Corp DRB150549 Jonathan Final review of an exterior alteration (landscaping) 100 Vail Road/Lot 35, Block 7, Vail Village Filing 1 Applicant: Fisher 7131 Corp, represented by Nedbo Construction The applications and information about the proposals are available for public inspection during regular office hours at the Town of Vail Community Development Department, 75 South Frontage Road. The public is invited to attend the project orientation and the site visits that precede the public hearing in the Town of Vail Community Development Department. Times and order of items are approximate, subject to change, and cannot be relied upon to determine at what time the Planning and Environmental Commission will consider an item. Please call (970) 479-2138 for additional information. Sign language interpretation is available upon request with 48-hour notification. Please call (970) 479-2356, Telecommunication Device for the Deaf (TDD), for information. Page 2 1/5/2016 0 TOWN OF VA10 PLANNING AND ENVIRONMENTAL COMMISSION December 28, 2015, 1:00 PM Vail Town Council Chambers 75 S. Frontage Road - Vail, Colorado, 81657 Call to Order — Members present Brian Gillette, Webb Martin, John Rediker, Henry Pratt Ludwig Kurz, John Ryan Lockman Members Absent: Kirk Hansen Swearing -In New PEC Member Ludwig Kurz by Patty McKenny, Town Clerk Poll of Board to see if the site visit on the work session (#4) is necessary. The board decided that a site visit is not needed. 2. A request for a minor amendment to SDD No. 4, Cascade, pursuant to Section 12-9A-10, Amendment Procedures, Vail Town Code to allow for converting an indoor tennis court into parking, located at 1295 Westhaven Drive/Lot 48, Glen Lyon Subdivision, and setting forth details in regard thereto (PEC150035). Applicant: L -O Westhaven, Inc., represented by Mauriello Planning Group Planner: Chris Neubecker Action: Table to January 11, 2016 Motion: Rediker Second: Kurz Vote: 5-0-1 Pratt recused A request for the review of a conditional use permit, pursuant to Section 12-713-3, Permitted and Conditional Uses; First Floor or Street Level, Vail Town Code, in accordance with the provisions of Chapter 12-16, Conditional Uses, Vail Town Code, to allow for an outdoor patio, located at 278 Hanson Ranch Road (Crespelle Restaurant)/Lots A -C, Block 2, Vail Village Filing 1, and setting forth details in regard thereto. (PEC150033) Applicant: 104-6 LLC, represented by Drew Riley Planner: Jonathan Spence Spence: Applicants have worked with their neighbor on a revised site plan layout. Seats will only be in front of the restaurant in winter, in summer it would be similar to the layout from two weeks ago. Lockman: Asked to see the location of the ski racks. Planner Spence showed the revised plans, including a winter layout and summer layout. Pratt asked about the location of the trash elevator. Spence: Per the agreement, the railings must be removed each evening to provide access to the trash elevator. Rediker: Will there be planters, or will this be like Mountain Standard? Spence: The same railing as Big Bear, with planters. 1/5/2016 Rediker: Do they need to replace pavers if the railings and business go away? Spence: Yes, per the Revocable ROW Agreement. Rediker: Do they need to keep the area free of snow? Martin: What is above this space? Is there potential for falling snow? Spence: This is a pedestrian area now. We are not aware of any snow shedding problems in this area. Rob Glucksman: I represent the ownership group on this application. The situation with the adjacent tenant has been taken care of. Lockman: Is there anything in writing from the neighboring business stating they approve of this design? Spence: No, but the application went through the HOA. Rediker: On the six criteria in the Code, and as the staff memo indicates, I think the criteria are met. Martin: It meets the criteria of the Vail Village Master Plan. This is good for the village. Pratt: Does this Conditional Use sunset or expire? Spence: No, but as a Conditional Use the Board can review this permit at any time. Action: Approve Motion: Rediker Second: Lockman Vote: 6-0-0 4. A request for a work session with the Planning and Environmental Commission to discuss properties in the Two -Family Residential (R) District and the Two -Family Primary/Secondary Residential (PS) District that were annexed into the Town of Vail with two dwelling units but are now nonconforming uses due to lot size requirements. — 90 min. Planner: Jonathan Spence Spence: This work session is not intended to discuss the minimum lot size for the zone districts. There are 34 duplex properties in Town, annexed after they were platted and constructed in Eagle County. All currently have 2 units, and are on lots less than 14,000 sq. ft. As a result, they are legal, nonconforming and no GRFA can be added to the properties, even if the code calculations allow more GRFA. Premise of nonconforming is that they will eventually go away due to redevelopment. In all practical senses, these uses will not go away. In the past we have allowed 250 sq. ft. additions. As a result of separate ownership and improvements made over time, the possibility of them going away is unlikely. This would create a hardship for these properties. The lots are dispersed in northwest Vail, southwest Vail and a few in East Vail. Sizes range from 8,000 sq. ft. to almost 14,000 sq. ft. We are looking at all these properties as a whole. Goal of this meeting is as stated in the memo. Page 9 shows some of the possible consequences of taking action or no action. Several members of the public are here today, as well as Tom Braun, representing a particular applicant. 1/5/2016 Gillette: If one the properties burned to the ground, would it need to be developed per the town code? Spence: Code allows rebuilding for replacement in case of fire or total loss, but to the same dimensions. But voluntary redevelopment would require rebuilding as a single family home, not two units. Gillette: If the lot size allows greater GRFA, we would not allow the GRFA to be used, is that right? Martin: In the past, have properties come forward for a variance? Spence: No. Some ways to come into conformance would be to convert two units into one, or deed restricting one of the two residential units as an EHU (Employee Housing Unit). Rediker: Is there no other legal avenue, except to modify the Town Code? Spence: That is true; but a variance is not the right way to go forward, since you would have to argue against the Town Code. Rediker: How did you determine the 34 lots? Spence: Through Town's GIS system. Rediker: Is the Town looking to eliminate Section 12-18-2, or write some other exemption? Spence: More to the latter. We would likely keep Section 12-18-2 in some form. Gillette: Are you suggesting that we allow GRFA based on a larger lot? Spence: No. Gillett: But allow them to use the GRFA? Spence: Yes. Gillette: How would you do this? Create another zone district? Spence: We would like to discuss this with the Town Attorney. We want to make these 34 lots legal. Gillette: Are these in the Primary Secondary lots or Two Family / Duplex? Would you change the zoning? Spence: We see no reason to change the zone district. Pratt: You mentioned that there used to be a 250 sq. ft. addition allowed. Do you know how many of these lots took advance of that allotment? Spence: No Gillette: Would you reset the 250 allotment? Spence: There are some examples of one side of the duplex that took advantage of the 250 conversions, and the other side cannot now do the same. If a 250 was used will not effect the allowable GRFA for the lot. 1/5/2016 Rediker: What happens if there is one lot that is subdivided? Spence: The zoning code considers the subject lot as one lot for calculating site coverage and GFRA. Martin: Are any lots outside the Transfer Tax boundary? Spence: All are located inside the Town of Vail boundary Public Comment Gene Grace, 1905 West Gore Creek Drive: Purchased our home about a year ago. We have safety issues on our stairs. They do not meet code. We need to push out a wall to rebuild the stairwell. We met with Jonathan a few times. We would be nonconforming to fix the stairwells. There are also longer term issues such as parking. We have to back our car into the street. Garages are very small. We looked at changing the garage entrance. We want to improve the safety and livability and bring up to compliance with Town Code Ken Bridges, Architect: Structure we're working on, there are no options. Dilapidated stairwell is covered and counts as GRFA. If it was a single family home, we could double the GRFA. We want to make it more livable. It would be good for Town and my clients. Any changes to code would help. Tom Braun, representing Mr. and Mrs. Grace: My clients have available GRFA that they can't use. Started working with the Graces in the fall. We knew there were some issues. We knew that the units were not conforming to minimum lot size. I was floored when Jonathan said we could not use the GRFA. Every code has a nonconforming section. Regulations change, that's why you have nonconforming sections of the code. Some codes are strict and have amortization requirements. Can't increase discrepancy; only have to address issues related to the change or addition. But in the density control section of code, it lumps together number of units and GRFA. Density and GRFA are different. Code creates a bottleneck that prohibits the use of GRFA if nonconformity is due to number of units. Purpose of code is to prevent discrepancy from increasing. Not allowing use of GRFA does not address the density or number of units. There are a lot of owners in this position. Not just my clients. About half of the owners of these lots are Vail locals. Town goal is to keep locals in Town. You should keep the nonconforming section of the code, but look at the section where it merges density and GRFA. I have offered Jonathan my services to help staff find a solution to this problem. Gillette: Is it just Section 12-18-5B that we need to address? Mr. Braun: We would like to address the unit per acres section and GRFA. But we need to look at unintended consequences. We have not looked at all solutions Spence: Section 12-18-513 also applies to multifamily properties. It's important to access GRFA, but also to allow a demo -rebuild. John Perkins: Architect: Working with the Grace Family. The design is an extremely weak mirror image duplex. This change would give us an opportunity to address this mirror image, which is discouraged. Final Comments Gillette: We should pursue this. We do not want to create a special circumstance. We should allow them to use the GRFA per the code. Allow the second unit of full ownership. You are on the right track. 1/5/2016 Martin: Staff needs to move forward with this to allow enhancement of these properties. EHU (Employee Housing Units) solution did not work. Concerns I have are on setbacks and parking, but still allow owners to use the GRFA. Questions: #1, yes, they are acceptable. Staff is on the right path. Rediker: Agree with comments so far. Looking at this issue and the GRFA, this does meet the goals of the Town. Devil's Advocate is that there is a direct link between GRFA and density. In certain situations a variance may apply. In the Grace's situation, the fact that they have to bring the property up to Town code, that would meet criteria for a variance. We should look at this closer. Any other nonconformity that can be remedied should be brought into conformance, including parking and setbacks where possible. Are we looking at allowing full demo -rebuild, as long as it's in compliance with code? Spence: If we would allow a demo -rebuild; at end of day we would have structure that meets setbacks and has same GRFA as a single family that could be built on same lot. Rediker: Agree with that sentiment, demo -rebuild should be considered. Gillette: Would we require a setback to be fixed if new GRFA was added? Rediker: No, just for new construction Kurz: We should go forward to address this issue. Staff found some inequities in code. Allow staff to look at the technicalities. We need more information from staff so we can consider the unintended consequences. This is an opportunity to help keep locals in the community. We should more forward expeditiously. Lockman: This trend will not go away, properties are aging. We would allow people to make revisions to come into compliance with code. We want to keep locals in the community and keep ownership affordable. Allowing more GFRA will increase density. Adding sub -paragraphs to the portion on GRFA could be a solution. We should pursue this as soon as possible. Pratt: The restriction on density in the nonconforming section seems unfair; I would be OK creating a list of these properties in the code. We need to be careful not to create a special windfall for these properties. Mr. Braun mentioned that we cannot increase the nonconformity. Staff is on the right track. Will leave it up to staff on how to approach this issue. Spence: We plan to meet with our legal team to understand how to move forward. Gillett: Also look at how to allocate the GRFA if lots have been subdivided. Our duplex language is not strong enough to prevent conflict among duplex owners Action: Table to January 25, 2016 Motion: Rediker Second: Martin Vote: 6-0-0 5. A request for final review of a Development Plan, pursuant to Section 12-61-11, Vail Town Code, to allow for the future development of Employee Housing Units on the Chamonix parcel located at 2310 Chamonix Road, Parcel B, Resubdivision of Tract D, Vail Das Schone Filing 1, and setting forth details in regard thereto. (PEC150019) - 5 Min. Action: Table to January 25, 2016 Motion: Martin Second: Kurz Vote: 6-0-0 6. Approval of Minutes 1/5/2016 November 23, 2015 PEC Meeting Results Action: Approve Motion: Rediker Second: Lockman Vote: 4-0-2 Abstain: Kurz, Pratt December 14, 2015 PEC Meeting Results Action: Approve Motion: Gillette Second: Lockman Vote: 3-0-3 Abstain: Kurz, Martin, Rediker 7. Informational Update Mr. Neubecker gave an update on the new planners in the department. There was some discussion on changes to the Building Code. The new codes go into effect for applications submitted after January 1, 2016. 8. Adjournment Action: Adjourn Motion: Rediker Second: Kurz Vote: 6-0-0 The applications and information about the proposals are available for public inspection during regular office hours at the Town of Vail Community Development Department, 75 South Frontage Road. The public is invited to attend the project orientation and the site visits that precede the public hearing in the Town of Vail Community Development Department. Times and order of items are approximate, subject to change, and cannot be relied upon to determine at what time the Planning and Environmental Commission will consider an item. Please call (970) 479-2138 for additional information. Sign language interpretation is available upon request with 48-hour notification. Please call (970) 479-2356, Telecommunication Device for the Deaf (TDD), for information. 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Review Residential Sprinkler Requirements from currently adopted Codes PRESENTER(S): Mark Novak, Fire Chief, Mike Vaughan, Fire Marshal ACTION REQUESTED OF COUNCIL: No action on this topic is requested at this time. BACKGROUND: Town Council has requested more information on the threshold requirements that trigger a fire sprinkler retrofit during residential renovation projects. ATTACHMENTS: Memo Fire Sprinklers Presentation Fire Sprinkler Requirements 1/5/2016 I ffliln Memorandum To: From: Date: Subject Town Council Mike Vaughan, Fire Marshal, Mark Novak, Fire Chief December 28, 2015 Fire Sprinkler Requirements Background The Town of Vail enacted a sprinkler retrofit ordinance in 1984 following a fire at the Lodge Tower. In addition to the retrofit ordinance, the International Building Code (IBC) mandates fire sprinklers in most new commercial and multi -family occupancies. In 2009, the International Residential Code (IRC) began requiring fire sprinklers in new one and two family dwellings. When the 2009 IRC was adopted by the Town, it included amendments which provided exemptions to this requirement. These exceptions were specified in the Fire Sprinkler Matrix. The Matrix evaluates factors that impact the ability to rapidly suppress a fire including access, terrain, and the size of the structure. During the time between 2009 and today, the majority of new single family homes and duplexes did not meet the exception criteria found in the matrix and were required to be constructed with a fire sprinkler system. The Matrix is also used to determine if a fire sprinkler retrofit is required in major renovations of single family dwellings and duplexes. The Matrix was developed by the Fire Prevention Division of Vail Fire and Emergency Services and vetted by the Building and Fire Code Board of Appeals. The Board of Appeals consists of subject matter experts, including, architects, engineers, and contractors. Current Situation The adoption of the 2015 IRC eliminated the use of the matrix for installation of fire sprinklers in new one and two family dwellings. Sprinkler retrofit in renovations of one and two family dwellings will continue to be based upon the Matrix. The Matrix consists of two sections. The first section provides for standard exemptions from the sprinkler retrofit requirement. The exemptions are: 1. Exterior modifications. 2. Interior remodel that does not include removal of the ceiling. 3. Interior remodel that includes removal of the ceiling in less than 60% of the existing Gross Residential Floor Area (GRFA). 4. The addition of dormers. 1/5/2016 5. Conversion of crawl space to habitable space. 6. Replacement of doors, windows or trim. 7. The addition of new habitable space that is less than 25% of existing GRFA. 8. Mechanical, plumbing and electrical permits. If a project does not meet one of the exemptions listed above, then sprinklers are required if the following conditions are not met: 1. If the exterior perimeter is less than 300', and the site allows for year-round access by foot. 2. The driveway between the staging area and the right-of-way complies with Town of Vail Code. 3. The fire apparatus access and staging area is compliant with the minimum requirements found in the Town of Vail Code. 4. The site has adequate fire flow from a minimum of two hydrants within five hundred feet of the approved fire apparatus staging area. 5. The site meets the Town of Vail Wildland Urban Interface requirements. 6. The structure is two stories or less and all portions of the exterior are within 150' of the point of fire department access and all portions of the interior within 30' of the exterior. 7. The structure has an approved fire detection and alarm system. In 2015, a fire sprinkler retrofit was required in five existing single family dwellings or duplexes. In this same time period there were one hundred and thirty permits issued for projects in these occupancy types that did not require a fire sprinkler retrofit. New multifamily dwellings are required by the IBC to have a fire sprinkler system. Renovations in multifamily dwellings are required to retrofit with fire sprinkler when the scope of work triggers the application of the currently adopted code. Although there is no comparable substitute for the increased life safety provided by fire sprinklers, a major concern in many communities is the additional cost of a fire sprinkler system. In 2008 the National Fire Protection Association (NFPA) conducted a study which found the average cost per square foot in Fort Collins (closest region studied) for fire sprinkler installation was $3.81 per square foot. A follow up study by the NFPA found that this cost had dropped to $1.83 per square foot in 2013. 2015 Town of Vail permit data demonstrated an average installation cost of $ 4.00 per square foot. It is recognized that sprinkler retrofit is generally more expensive than installation in new construction. III. ACTION REQUESTED: No action is requested at this time. Does Council have any items that require additional information or clarification? IV. ATTACHMENTS 1. Fire Sprinkler Presentation Town of Vail Page 2 1/5/2016 �k "It ^i Fire Sprinkler Requirements Mike Vaughan Fire Marshal Office: 1.970.4 79.2252 Mobile: 1.970.390.7488 Mvaughan@vailgov.com Town of Vail I Fire Department 1 1/5/2016 1/5/2016 History of Fire Sprinklers in Vail (j�1JJfrit1-=�,,, is The fire and building codes dating back to the early eighties have mandated the installation of fire sprinklers in one form or another. • These requirements were based on code requirements similar to those found in the model codes that are in effect today. • These code requirements reflect the Town of Vail's concern for life safety of our guests and residents. k )TOWN OF VAIL"' Town of Vail I Fire Department 1 1/5/2016 3 1/5/2016 History of Fire Sprinklers in Vail (J�1JJfritJ-=�,,, • Fire and life safety systems — and the need for those systems, became the center of attention after a fire in a guest room at the Lodge Tower. • Thankfully there were only minor injuries. There was, however, substantial fire damage to the fire unit and adjacent units as well as smoke damage throughout. • Fire alarm and fire sprinkler retrofit installation became requirements with the adoption by the Town Council of a sprinkler retrofit ordinance in 1984. TOWN OF VA5IL" Town of Vail I Fire Department 1 1/5/2016 4 1/5/2016 Fire Sprinkler Installation Requirements • The requirement to install fire sprinklers was based on sections in the fire code regarding adverse conditions and site restrictions such as slope and access to the site. • These considerations included but were not limited to building site topography, building height and various construction and architectural features. TOWN OF VAIL"') Town of Vail I Fire Department 1 1/5/2016 5 1/5/2016 Fire Sprinkler Installation Requirements • Early retrofit requirements were based on a grading system that considered construction features of the built environment in Vail's condominiums, hotels and mixed use occupancies. • Construction type, building height, access and existing fire protection features were some of the criteria used to grade a building's risk of fire and the need for retrofitting with fire alarm and fire sprinkler systems. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 6 1/5/2016 Fire Sprinkler Installation Requirements J . J • As the building and housing stock aged, the desire for larger unique one and two family dwellings increased. A building era which included scrape and rebuilds began and continues today. Many of these projects were developed as two family (duplex) homes to maximize return on investment. That trend continues today. • The same criteria regarding access and accessibility, site topography and building features, among other considerations, was applied to these structures. TOWN OF VAIL"') Town of Vail I Fire Department 1 1/5/2016 7 1/5/2016 Fire Sprinkler Installation requirements • The 2009 International Residential Code was adopted by the Town of Vail and included section R313.2, which required the installation of fire sprinklers in all one and two family dwellings. • The Town of Vail amended this section so that the assessment criteria (matrix) developed by the Vail Fire Department would be used to determine the whether a project would require the installation of a fire sprinkler system. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 g 1/5/2016 Fire Sprinkler Installation Requirements • This tool was developed using criteria similar to that established in the infancy of the retrofit program, as well as code requirements. E1 Town of Vail I Fire Department 1 1/5/2016 9 1/5/2016 Fire Sprinkler Installation Requirements • The Sprinkler Installation Matrix was discussed extensively through the course of the code adoption process. • Members of the appeals board approved the criteria to be included in the adoption process with the confidence that it was an accurate model that both reflected the intent of the building and fire codes, and could be applied fairly. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 10 1/5/2016 Fire Sprinkler Installation Requirements • The Building and Fire Codes Appeals Board is comprised of seven members, two of which are alternates • "The board of appeals shall consist of members who are qualified by experience and training to pass on matters pertaining to building construction and are not employees of the jurisdiction". (2012 IBC — 113.3) 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 11 1/5/2016 Fire Sprinkler Installation Requirements • The building and fire code board of appeals for the Town of Vail is comprised of two engineers, three architects (one which is an alternate) and two general contractors (one which serves an alternate). • Proposed new codes and amendments are submitted to and reviewed by the Board of Appeals. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 12 1/5/2016 Fire Sprinkler Installation Requirements SIJ! • The 2015 IRC as adopted by the Town of Vail is requires the installation of fire sprinklers in new one and two family dwellings. • The Sprinkler Installation Matrix will continue to be used to determine if extensive remodel projects require a sprinkler retrofit in one and two family dwellings. • Sprinkler retrofit is required in other occupancies when minimum access requirements as established by the code are not met or when the project is subject to current building code 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 13 1/5/2016 Fire Sprinkler Installation Requirements �1fr�,�sr'a �IJr11J���d I �J!J IIIIJ II��J r JIJ r �1J rJr� i fJJrJ `I 17:)Itet SIJ The Matrix provides the following exemptions to the requirement to retrofit with sprinklers: 1. 2. 3. 4. 5. 6. 7. Lee] Exterior modifications. Interior remodels that do not include removal of the ceiling Interior remodel that includes removal of the ceiling in less than 60% of the existing Gross Residential Floor Area (GRFA). The addition of dormers. Conversion of crawl space to habitable space. Replacement of doors, windows or trim. The addition of new habitable space that is less than 25% of existing GRFA (i.e. moving a kitchen wall out to capture deck space). Mechanical, plumbing and electrical permits. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 14 1/5/2016 Fire Sprinkler Installation Requirements '/r �rPr-I!JJr- ttJIJr 1 7 -.- If a project is not exempt, then sprinklers are required if the following conditions are not met: 1. If the exterior perimeter is less than 300', and the site allows for year-round access by foot 2. The driveway between the staging area and the right-of-way comply with Town of Vail Code 3. The fire apparatus access and staging area is compliant with the minimum requirements found in the Town of Vail Code. 4. The site has adequate fire flow from a minimum of two hydrants within five hundred feet of the approved fire apparatus staging area. 5. The site meet Town of Vail Wildland Urban Interface requirements. 6. The structure two stories or less and all portions of the exterior within 150' of the point of fire department access and all portions of the interior within 30' of the exterior. 7. The structure has an approved fire detection and alarm system. 6 TOWN OF VAIL ' Town of Vail I Fire Department 1 1/5/2016 15 1/5/2016 Fire Sprinkler Installation Requirements �1JP tl� 1Jr JJIJ1 i'-11 • VF&ES attempts to make an evaluation of the need for fire sprinklers at the either the conceptual phase or the DRB phase. • Discussions with architects, contractors and homeowners regarding a project are encouraged and often involve site visits to evaluate potential impacts of terrain, access or existing building conditions that may trigger requirements to install fire sprinklers. 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 16 1/5/2016 Home Fire Sprinkler Facts 1�1 r�,JrI � 1 fJ J r r -Ir 'P�JrJ1�J r �JJrJ f f J D E Al =]rf ) • Smoke alarms will significantly reduce the risk of dying in a home fire, however • Smoke alarms do nothing to suppress the fire. • When working together, smoke alarms and fire sprinklers have been proven to protect lives and property. • Fire Sprinklers in conjunction with smoke alarms reduce the risk of dying in a home fire by 80 percent. (NEPA) Town of Vail I Fire Department 1 1/5/2016 17 1/5/2016 Home Fire Sprinkler Facts -J `' P;-jmJJ r rj1J 11J11J I-)II1J--�j J IJP • In 2015 Fire sprinkler systems were installed or modified in three existing duplex units. • Fire sprinkler systems were installed or modified in two existing single family homes. • In 2015 approximately 135 permits were issued by the Town of Vail for remodel activities in existing one and two family dwellings. k )' TOWN OF VAIL Town of Vail I Fire Department 1 1/5/2016 18 1/5/2016 Home Fire Sprinkler Facts f � ;�fJfJl<_��I �fJ r�4����'rJJfJ M �f1� �if1�l r'��/J frlffjlJ� �����iJ111f1�J • In 2015 fire sprinkler systems were installed in five new single family residences. • Fire sprinkler systems were installed in thirteen new duplexes. • Average cost just under four dollars a square foot. • In 2015 sprinkler permit valuations were very close to one percent of total building costs. (TOV permitting information). 6 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 19 1/5/2016 Fire sprinkler activation J _ 'Df,JfJ.�r<_�EJ ��,.I\J • On New Year's eve 2014 a kitchen fire at the Lionsquare Lodge was controlled by the activation of a single sprinkler (155 degree temperature rating). • The fire was result of unattended cooking — occupant was in the next room when fire started. • The sprinkler kept the fire damage to a minimum — there were no injuries and occupants were able to remain in the unit. • Building is wood construction and had been retrofitted with sprinklers earlier that year. TOWN OF VAIL)' Town of Vail I Fire Department 1 1/5/2016 20 1/5/2016 Fire sprinkler activation Adr� �b j ( 1J)ffJ-J�.l1''jl�D1J J -r_J ��IJ IJ J�Jr� `�1J 1J �lld� ���I� rfJ�!J J�aIJ1S�Jl J Town of Vail I Fire Department 1 1/5/2016 1/5/2016 21 A Fire sprinkler activation • Afire in the kitchen of the Lord Gore Restaurant in the Manor Vail Lodge is extinguished by the activation of a single sprinkler. (155 degree temperature rating). • This fire occurred in the middle of the night after cleaning crews had left for the evening. • The building is wood construction. • The kitchen was back in service the same day. 0 TOWN OF VAIL' Town of Vail I Fire Department 1 1/5/2016 22 1/5/2016 Fire sprinkler activation • This fire was the cause of unattended smoking materials. • Unit was unoccupied at the time of fire. • There was water damage to this unit; the tenants were displaced. • The building is wood frame multi family structure. A Town of Vail I Fire Department 1 1/5/2016 23 1/5/2016 Fire sprinkler activations [AM nr UA11 Town of Vail I Fire Department 1 1/5/2016 1/5/2016 24 Side by side residential mock up units _r I � �.PJ JI�JJ �J JJ�J �JlJ ���.1 IJ J1' https://www.youtu be.com/watch?v=AH6J- Szo8dw FI Town of Vail I Fire Department 1 1/5/2016 25 1/5/2016 Questions Items for further clarification? Town of Vail I Fire Department 1 1/5/2016 1/5/2016 26 ■ , r -111w is it 00, y IT Lbinj • a- �. , I � ;���,�� �* ��' v 'lel �,rl l , � ,I,�,i,�;l L I Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Discussion of various Funding Options for the Chamonix housing development. PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the various options and provide staff guidance on next steps in selecting a preferred funding alternative, and provide feedback on the following: . What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? . What is the Town Council's tolerance for financial risk and desired level of investment? BACKGROUND: Funding is a critical consideration prior to moving forward with this housing development. The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the funding options to pursue. That decision point will need to occur in this first quarter of 2016. ATTACHMENTS: Staff Memorandum Funding Memo PPT Presentation 1/5/2016 0 rowN of vain Memorandum To: Vail Town Council From: Community Development Department Date: January 5, 2016 Subject: An Overview of Funding Options PURPOSE Town staff was instructed to propose and present funding options for the Chamonix Development for the Vail Town Council's review and consideration. The purpose of this public hearing is for the Town Council to review the various options and provide staff guidance on next steps in selecting a preferred funding alternative and provide feedback on the following: What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? What is the Town Council's tolerance for financial risk and desired level of investment? II. SUMMARY Funding is a critical consideration prior to moving forward with this housing project. No matter which development option is elected by Council, the below outline of potential financing methods are intended to provide an overview of the town's capacity for funding. Staff would appreciate feedback from Council III. DISCUSSION The following financing options are preliminary, and are intended to give Council a broad overview of the town's financial capacity as the various funding options and development options are considered. Town Debt The town is currently debt -free, so there is a potential for new debt to be issued. However, the kind of debt would need to be considered, such as Certificates of Participation (COPs) or General Obligation Revenue Bonds or Sales Tax Revenue Bonds. COP's would require the town put up town -owned building(s) as collateral, such as the municipal building, the Lionshead Welcome Center, etc. COP's do not require voter 1/5/2016 approval. Council should ponder the risk of a housing project success/failure when using town buildings as collateral. A $40M COP would obligate the town to annual debt service payments of $2.075M over 30 years. Total interest paid over the 30 years amounts to $22.OM. General Obligation Revenue Bonds or Sales Tax Revenue Bonds would require voter approval and are repaid from future "general revenues" or future sales tax collections. A $40 million bond issue for example would obligate the town to annual debt service payments of $2.1 M over 30 years. Total interest paid over the 30 years amounts to approximately $22.OM. Cash Financing While the overall town reserves are healthy, not all of those reserves are available for spending on this project. For example, RETT, Dispatch Services Fund, Health Insurance Fund and the Heavy Equipment Fund are not appropriate resources for cash funding. The Capital Projects Fund is the most appropriate source and is projected to have an ending fund balance of $13.6 million at the end of 2016. Over the next five years the fund balance will fluctuate between $16 million and $25 million over the next five years assuming no new projects are approved. There are several projects currently on the town's "unfunded list" (such as improvements to the Lionshead parking structure, expanded parking in Lionshead, the Intermountain Fuels project and reconstruction of the round -abouts), as well as projects that aren't on any list as yet (a Multi -Use Facility for example). Committing the town to either cash funding or debt service obligations will be a significant exposure to the town financially, and will impact the possibility and/or timing of future capital projects. The General Fund is the only other available source, with a projected fund balance of $19.2 million at the end of 2016. Please note that there is a Council directive to maintain a minimum balance in the General Fund of 25% of annual revenues (or approximately $9.2 million), and staff would not recommend depleting the reserves down to the minimum amount. Tax -Increment Financing (TIF) Please see the attached memo from the Town Attorney regarding the potential for use of Vail Reinvestment Authority TIF dollars toward this project. There could be potential for a new tax increment financing (TIF) district, however recent legislative changes have made TIF districts challenging to navigate. Other challenges could arise from the incremental taxes on the new residential property may not support the level of financing desired, and the Chamonix area may not fit the criteria for a TIF district. Assuming the above challenges were met, it would also take time to establish a new district and then bond on future property tax increments once the project was completed. IV. FUNDING OPTIONS Town of Vail Page 2 1/5/2016 The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the funding options to pursue. That decision point will need to occur in this first quarter of 2016. Option 1: 100 % Town of Vail Funding Key Points: • The Town of Vail has budgeted $2M in the 2016 Capital Budget for the construction of the required site access and infrastructure and has contracted 359 Design for the preliminary site plan and engineering. • The Town of Vail has already invested over $2.5 M of General Funds to acquire the property. • A subsequent phase of development is vertical construction of the buildings. To complete the vertical construction the Town of Vail may decide to act as the financing entity. • Town of Vail assumes the risk of the project financial and political. • Town Council must decide on risk tolerance to assume debt or use cash reserves. • The Arosa Duplex is an example of this approach to funding: o Town of Vail continues to own the land; o There is a $25 per year 99 -year Land Lease with each owner; o The two units were built and sold to qualified owners for the cost of development. o The two units were sold in the low $400 thousands. Pros: 1. Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units 2. Prices may be set based on affordability, market or a combination of the two 3. Town of Vail may change parameters without needing any other financing entity or investment partner's approval 4. Decision making process can be accelerated 5. Town of Vail may ensure best product to meet demand without concurrence of other entities 6. Town of Vail maintains ownership of the land to help ensure affordability over time Cons: 1. Development financing isn't primary business of the Town of Vail 2. Town of Vail assumes all financial risk 3. Financial and political risk falls on town alone 4. Risk management in housing development is not in purview of local government Town of Vail Page 3 1/5/2016 Option 2: Government Funding Programs Key Points: • Currently no state or federal funding programs support subsidies for homeownership above the 80% AMI level. o Government Funding would only fund portion of project that meets regulatory requirements o Town of Vail would still be required to fund remaining portion of project, i.e., all units above 80% of AMI income levels. • Town staff would be responsible for up front application process and backside federal regulatory compliance issues. • Competitive process with application deadlines and limits on per project investments (based upon available funding). • Relevant programs through the State Division of Housing (DOH): o The HOME Investment Partnership Program provides competitive funding to local governments, non -profits, and private developers in support of activities to buy, build or rehabilitate housing for rent or ownership by households at or below 80% AMI; o The Community Development Block Grant (CDBG) program is used by DOH to provide or improve permanent residential structures for households at or below 80% AMI in areas of the state outside of the larger cities and counties; o The Housing Development Grant Fund (HDG) provides funds for acquisition, rehabilitation, and new construction to improve, preserve or expand the supply of affordable housing; o Private Activity Bond (PAB) program funds privately developed projects: ■ The bonds are tax-exempt and the amount of the bonds issued are limited by the IRS; ■ Municipalities or housing authorities issue the bonds, but have no obligation to repay the investors. Investors purchase the bonds. • Colorado Housing Finance Authority does have a mortgage product with a 3% down payment for applicants up to 110% of AMI through their approved lenders. • FHA/Fannie Mae project approval is needed to allow secondary market sales of mortgages, opening the door to federally backed 3% down payment mortgages and down payment assistance for 80% of AMI and below families through local lenders. • An example of the use of government funding programs for a housing development in Vail is the Middle Creek Apartment development. o The VLHA acted as the agent for the Town for their required nonprofit minimum ownership status. o The project used 4% Low Income Housing Tax Credits (LIHTC) to obtain equity investors to fill a gap in the financing. o A requirement of this financing is that 69 % of units are restricted to 60% AMI & below. Town of Vail Page 4 1/5/2016 Pros: 1. Reduces financial risk to Town of Vail with government grants and/or low interest loans 2. Reduces the outlay of General funds from Town of Vail 3. Federal participation in projects can attract private sector funding and/or reduce the amount of debt needed for the project 4. Funding source is consistent and stable 5. Private Activity Bonds could present a viable funding source Cons: 1. Federal requirements could make construction of affordable units more costly 2. Private developers could be wary of federal restrictions/requirements 3. Considerable staff resources are required for application process and regulatory compliance issues 4. Application deadlines and timing may delay development 5. Competitive process with no guarantee of successful application 6. Bonds could require voter approval 7. Must be used for Low to Moderate Income (LMI) households and therefore only applicable proportionately in a mixed income project. Option 3: Joint Venture Key Points: • The Town of Vail shares risk with joint venture (equity) partners in the development, i.e., seeks investment from large employers (who need permanent housing for year-round FT employees) and/or Private Developer Partner. • The Town of Vail enters into a Joint Development Agreement specifying the amounts of investment and equity stake of the partners. • The Town of Vail may choose to enter into a development agreement with a for- profit or non-profit developer to complete the Chamonix Development, getting an equity investment for a return on investment (ROI) to the Developer. • The Red Sandstone Development is an example of this approach to funding. o The Red Sandstone Townhome Development (condominiumized) was a joint Venture with the Eagle River Water & Sanitation District (ERW&SD) to create Employee Housing; o The land was donated into the deal proportionately by both JV Partners 2/3 by ERW&SD and 1/3 by TOV; and o A zero interest construction loan was made to the Developer to construct the units at cost plus 6% (developer fee), again proportionately split between the partners. o These units range in price today from $175,000 to $295,000. Pros: 1. Reduces financial risk to Town of Vail with equity investments 2. Shared risk among Joint Venture Partners 3. Private sector development knowledge and experience to manage risk 4. Timely implementation from private sector partner driven by profit Town of Vail Page 5 1/5/2016 5. Knowledge of the market and the financing community Cons: 1. Feasibility of enlisting Joint Venture Partners, i.e., are there willing partners to participate 2. Project can go awry if mission and goals of the partners are not aligned 3. Town of Vail relinquishes some control to Joint Venture Partners and/or Private Developer Partner 4. For-profit "culture" vs. community's affordable housing priorities 5. Private Developer Partner could withdraw if financing gap increases during implementation 6. Clear Joint Venture and/or development agreement defining partner roles takes time Option 4: 100% Private Development Funding Key Points: • Subdivide the site into three or four development parcels and transfer the site to private sector bidders • Parcels could be: o the duplex parcel along Chamonix Lane o the townhome parcel along Chamonix Road o the multi -family parcel along Chamonix Road o a fourth parcel of free market lots could also be platted • Parcels would be sold with the stipulation that the parcels be deed restricted and developed as affordable housing with zoning controls. • Deed Restrictions could be used to differentiate among the income levels: o Residency Restriction only o Employment in the Town of Vail o Employment in eagle County (30+ hours per week) • The proceeds from the sale of these free market lots could be used to help subsidize the affordable unit development. • The Town of Vail may offer financial incentives to entice the private sector to maximize the affordability or to meet "pre -determined" sales prices. • The Lion's Ridge Apartment Development is an example that closely mirrors this approach. o Eastern half of 10 -acre Timber Ridge Site redeveloped by Private Sector 0 113 units of 1 & 2 -bedroom apartments o Private financing of $27M for development 0 50 -year Land lease with purchase option in first 10 -years at $5M Pros: 1. Eliminates/reduces financial risk to Town of Vail through the use of private funding 2. Private sector expertise - market and construction techniques Town of Vail Page 6 1/5/2016 3. Financial incentives can be less costly than direct investment Cons: 1. Town of Vail loses ownership of land upon sale 2. Risk of not accomplishing affordability goals increases 3. Profit margin may limit ability to fill the affordability gap 4. Need for financial/regulatory incentives may outweigh risk of direct investment 5. Developers not accustomed to producing housing for lower AMI levels 6. Private financing for deed -restricted units may be difficult to obtain III. STAFF RECOMMENDATION The Community Development Department requests the Vail Town Council consider the various options and provide staff guidance on next steps in selecting a preferred funding alternative, and provide feedback on the following: What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? What is the Town Council's tolerance for financial risk and desired level of investment? Town of Vail Page 7 1/5/2016 HP WC Hoffmann Parker Wilson & Carberry I P.C. Corey Y. Hoffmann Denver Office Kendra L. Carberry 1530 16' Street, Suite 200 Jefferson H. Parker Denver, CO 80202-1468 M. Patrick Wilson (303) 825-6444 Of Counsel Vail Office J. Matthew Mire21- P.O. Box 2616 Vail, CO 81658 (970) 390-4941 VAIL REINVESTMENT AUTHORITY MEMORANDUM TO: MAYOR AND TOWN COUNCIL FROM: J. MATTHEW MIRE, TOWN ATTORNEY KENDRA L. CARBERRY, ESQ. \�' DATE: DECEMBER 7, 2015 RE: USE OF TIF FUNDS TO CONSTRUCT EMPLOYEE HOUSING Ryan S. Malarky Elizabeth R. Cross Kathryn M. Sellars Ashley N. Pollock Jessica B. King This memorandum addresses whether Tax Increment Finance ("TIF") funds may be used by the Vail Reinvestment Authority (the "VRA") to construct employee housing under the Lionshead Public Facilities Plan (the "Lionshead Plan") when the housing would be located outside the urban renewal area designated in the Lionshead Plan. Urban Renewal Generally Under the Urban Renewal Law, C.R.S. § 31-25-101, et seq. (the "URL"), an urban renewal authority such as the VRA may not undertake urban renewal projects until the authority has adopted an urban renewal plan for the blighted area. An "urban renewal plan" is defined as: [A] plan ... for an urban renewal project, which plan conforms to a general or master plan for the physical development of the municipality as a whole and which is sufficiently complete to indicate such land acquisition, demolition and removal of structures, redevelopment, improvements, and rehabilitation as may be proposed to be carried out in the urban renewal area ...... C.R.S. § 31-25-103(9)(emphasis added). Despite the foregoing, the URL does not expressly address whether an urban renewal authority may expend TIF funds outside of its urban renewal boundaries. However, the URL is clear that TIF funds may only be used to fund urban renewal projects. C.R.S. § 31-25-107(9)(a)(II). Urban renewal projects are defined as: 1217/2015 Q: I USERSI VRA MEMM2015TMPLOYEE HOUSING-M120715.DOCX 1/5/2016 December 7, 2015 Page 2 [U]ndertakings and activities for the elimination and for the prevention of the development or spread of slums and blight and may involve slum clearance and redevelopment, or rehabilitation, or conservation, or any combination or part thereof, in accordance with an urban renewal plan. Such undertakings and activities may include: (b) Demolition and removal of buildings and improvements; (c) Installation, construction, or reconstruction of streets, utilities, parks, playgrounds, and other improvements necessary for carrying out the objectives of this part 1 in accordance with the urban renewal plan; (d) Disposition of any property acquired or held by the authority as a part of its undertaking of the urban renewal project for the urban renewal areas (including sale, initial leasing, or temporary retention by the authority itself) at the fair value of such property for uses in accordance with the urban renewal plan; (e) Carrying out plans for a program through voluntary action and the regulatory process for the repair, alteration, and rehabilitation of buildings or other improvements in accordance with the urban renewal plan; and C.R.S. § 31-25-103(10). Further, the legislative history of C.R.S. § 31-25-103(10) demonstrates that the Colorado General Assembly amended the definition of "urban renewal project" in 2005 to remove the express requirement that the activity occur within the boundaries of an urban renewal area. Senate Bill 05-224. This modification indicates a legislative intent to allow urban renewal authorities to expend funds outside of their boundaries. Nonetheless, the other statutory language of the URL and related case law make clear that all urban renewal activity must ultimately be tied to remedying conditions in the urban renewal area. Based on the foregoing, it is our opinion that the VRA may expend funds outside its urban renewal area boundaries if the VRA can establish a reasonable relationship between its expenditure and the elimination or prevention of the spread of slum or blight within the urban renewal area. Application to Lionshead Plan The Lionshead Plan largely addresses public infrastructure deterioration. The Lionshead Plan states that it is "intended to provide the financial mechanisms necessary to support the 12/7/2015 Q: I USERSI VRA MEMM201 STMPLOYEE HOUSING -M12071 S.DOCX 1/5/2016 December 7, 2015 Page 3 renovation and reconstruction of the public infrastructure in Lionshead." See Lionshead Plan § 1.2. The blight factors identified by the blight study and the Lionshead Plan are: (1) the Town's defective and inadequate street layout; (2) unsafe traffic and circulation patterns; (3) deterioration of public parking areas, retaining walls, and curbs and gutters; (4) restrictive covenants that render title unmarketable; (5) environmental contamination resulting from runoff; and (6) inadequate public improvements! While the blight identified in the Lionshead Plan is primarily related to infrastructure deficiencies, the stated objectives of the Lionshead Plan are to: 1. Create a sense of place and an improved aesthetic character for Lionshead for both residents and guests; 2. Renovate or develop the deteriorated and/or outdated residential and commercial buildings and provide enhanced amenities; 3. Enhance the aesthetic appearance of the area to make it more appealing; 4. Improve pedestrian, bicycle, mass transit and auto accessibility and circulation; 5. Eliminate impediments to the redevelopment of key facilities within the Plan area; and 6. Upgrade and restore public infrastructure, including transportation facilities, parking, sidewalks and streetscapes. See Lionshead Plan at § 3 (emphasis added). Finally, the Lionshead Plan expressly acknowledges that: Redevelopment and rehabilitation actions within the Plan Area may include such undertakings and activities as are in accordance with [the] Plan, the Lionshead Master Plan, and the Urban Renewal Law, including without limitation: demolition and removal of public buildings and improvements as set forth herein; installation, construction and reconstruction of public improvements as set forth herein; elimination of unhealthful, unsanitary or unsafe conditions; elimination of obsolete or other uses detrimental to the public welfare; and other actions to remove or to prevent the spread of deterioration. ' The inadequate public improvements identified are all infrastructure related: "streets and sidewalks on public property are not adequate for the traffic and do not provide a safe separation for pedestrians from motor vehicles. Pavement, curb and gutter and retaining walls on public property are deteriorating. Overhead utilities are present and stormwater management is inadequate." See Lionshead Plan § 2.1(f). 12/7/2015 Q: I USERSI VRA MEMM2015TEMPLOYEE HOUSING-M120715.D0CX 1/5/2016 December 7, 2015 Page 4 See Lionshead Plan § 4.1. While the Lionshead Plan contemplates the demolition and removal of public buildings, the Plan only contemplates the construction and reconstruction of "public improvements." Id. Further, the "inadequate public improvements" identified in the Lionshead Plan include only streets, sidewalks, pavement, curb and gutter, retaining walls, overhead utilities and the Town's storm water management system. See Lionshead Plan § 2.1(f). Therefore, there is a risk using TIF funds to build employee housing, which would likely be held in private ownership, even if such construction might further the objectives of the Lionshead Plan as written. Amendment of the Lionshead Plan There are several amendments that the Town could make to the Lionshead Plan to include the construction of employee housing. These include adding the area where the employee housing will be located to the plan area, and amending the Lionshead Plan to expressly include the construction of employee housing. Modification to Include Property Inclusion of the property where the employee housing is located would involve a change in the land area of the existing plan, would be considered substantial, and would require re - approval of the Lionshead Plan. The process to re -approve is virtually identical to the process required for the creation of a new renewal plan. C.R.S. § 31-25-107. As such, the inclusion of new property would require a blight determination for the added property and a public hearing by the VRA. C.R.S. § 31-25-107. Adding the property to the Lionshead Plan allows TIF funds to be used to fund the building of the employee housing, because it would become an urban renewal project. C.R.S. § 31-25-107(9)(a). However, the 25 -year TIF collection period would revert back to June 2005, when the 25 -year TIF period for the Lionshead Plan original began.2 A substantial modification would also reopen the discussion of whether blight exists within the Town by requiring a new blight determination for the property. Most problematic, however, is the impact of House Bill 1358 on inclusion of the property. Any alteration in the boundaries of an urban renewal area would require that the Lionshead Plan comply with House Bill 15-1348 (addressed by separate memorandum). Modification to Allow Construction of Employee Housing We would also recommend that the VRA amend the Lionshead Plan to allow for the construction of employee housing. Although the amendment would not change the land area, 2 Once the property is added into the Lionshead Plan, the base valuation for the property would be the value last certified prior to the effective date of the modification of the Lionshead Plan. C.R.S. § 31-25-107(9)(a)(I). 12/7/2015 Q: I USERSI VRA MEMM2015TMPLOYEE HOUSING-M120715.DOCX 1/5/2016 December 7, 2015 Page 5 design, building requirements, timing or procedure of the Lionshead Plan, it may fall under a change in the land use. C.R.S. § 31-25-107(7). Currently, the Lionshead Plan is directed at the redevelopment of public facilities and public improvements. As described above, that scope likely does not include the construction of privately -owned employee housing. See Lionshead Plan § 2.1(f). Therefore, the amendment would likely be considered substantial and require compliance with re -approval process, and require that the Lionshead Plan comply with House Bill 15-1348. Conclusion If the VRA would like to use TIF for construction of privately -owned employee housing, we would recommend that the Lionshead Plan be amended as described above. The amendment will necessitate a new blight study and a public hearing, as well as full compliance with House Bill 15-1348. As always, if you have any questions or concerns, please do not hesitate to contact us. 12/7/2015 Q: I USERSI VRA MEMM201 STEMPLOYEE HOUSING -M12071 S.DOCX 1/5/2016 Chamonix "Nail's newest residential neighborhood for families."' "...growing a thriving and balanced community" Town of Vail I Community Development 1 1/5/16 1/5/2016 TOWN OF 0 VA Purpose: 0 0 0 0 Background Project Guidelines and Goals Presentation of Funding Options —Town's Role — Pros & Cons Schedule Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Project Guidelines and Goals: Optimize site for workforce for -sale housing (15 - 25 du's per acre) Context Sensitive Design Solution Phased Approach Desirable, marketable and diverse housing products Maximize limited financial resources Build responsibly considering topography and natural features Diversified cost/sales structure Town of Vail I Community Development 1/5/16 - Vail Town Council, April 2015 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? 2. What is the Town Council's tolerance for financial risk and desired level of investment? Town of Vail I Community Development 1/5/16 0 TOWN OF VAIL"' 1/5/2016 Tolerance of Risk and Affordability? Option 4 Option 3 Private Development Joint Venture Funding Option 4 Private Development Funding Option 3 Joint Venture Town of Vail I Community Development 1/5/16 Option 2 Government Funding Option 1 ToV funding alone Option 2 Option 1 Government ToV funding alone Funding 1/5/2016 0 rowN of va Option 1: 100 % Town of Vail Funding Key Points: • The town has budgeted $2M in the 2016 Capital Budget for the construction of the required site access and infrastructure and has contracted 359 Design for the preliminary site plan and engineering. • The Town has already invested over $2.5M of General Funds to acquire the property. • To complete the vertical construction the Town may decide to act as the financing entity. • Town alone assumes the risk of the project financial and political • Town Council must decide risk tolerance to assume debt or use cash reserves • The Arosa Duplex is an example of this approach Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 1: Pros & Cons Pros: • Town of Vail has flexibility to make changes &adjust development parameters to increase absorption of units • Prices may be set based on affordability, market or a combination of the two • Town of Vail may change parameters without needing other financing entity or investment partner's approval • Decision making process can be accelerated • Town of Vail may ensure best product to meet demand • Town of Vail maintains ownership of the land to ensure affordability Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option 1: Pros & Cons Cons: • Development isn't primary business of the town • Town of Vail assumes all financial and sales risk • Financial and political risk falls on Town of Vail • Risk management in housing sales is not in purview of local government Town of Vail I Community Development 1 1/5/16 1/5/2016 0 rowN of VAIL Option 2: Government Funding Programs Key Points: • Currently no State or federal funding programs support subsidies for homeownership above the 80% AMI level. — Would only fund portion of project that meets regulatory requirements — Town of Vail would still be required to fund remaining portion of project. • Staff would be responsible for application process and regulatory compliance. • Competitive process with application deadlines and limits on per project investments (based upon available funding). • Relevant programs through the State Division of Housing (DOH): — The HOME Investment Partnership Program provides funding to local governments, non -profits, and private developers in support of activities to buy, build or rehabilitate housing by households at or below 80% AM I; — The Community Development Block Grant (CDBG) program is used to provide or improve permanent residential structures for households at or below 80% AMI in the state outside of the larger cities and counties; TOWN OF VAlt� Town of Vail I Community Development 1/5/16 1/5/2016 Option 2: Government Fundin Programs Key Points Co nt'd : — The Housing Development Grant Fund (HDG) provides funds for acquisition, rehabilitation, and new construction to improve, preserve or expand the supply of affordable housing; — Private Activity Bond (PAB) program funds privately developed projects: • The bonds are tax-exempt and the amount of the bonds issued are limited by the IRS; • Municipalities or housing authorities issue the bonds, but have no obligation to repay the investors. Investors purchase the bonds. • CHFA has a mortgage product with 3% down payments up to 110% of AMI through their approved lenders. • FHA/Fannie Mae project approval would allow secondary market sales of mortgages, opens door to 3% down payment mortgages and down payment assistance for 80% of AMI and below families. • The only example of the use of government funding for a housing project in Vail is the Middle Creek Apartment development. Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL # Option.2: Pros & Cons Pros: • Reduces financial risk to Town of Vail with government grants and/or low interest loans • Reduces the outlay of funds from Town of Vail • Federal participation can attract private sector funding and reduce the amount of debt needed • Funding source is consistent and stable • PAB's could present a viable funding source 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option.2: Pros & Cons Cons: • Federal requirements could make units more costly • Private developers could be wary of federal restrictions/requirements • Considerable staff resources are required for application process and regulatory compliance issues • Application deadlines and timing may delay development • Competitive process with no guarantee of success • Bonds could require voter approval • Must be used for Low to Moderate Income (LMI) households, i.e., only on units for 80% AMI & below 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option 3: Joint Venture Key Points: • Town of Vail shares risk with joint venture (equity) partners, i.e., seeks investment from large employers, who need permanent housing for FT year-round employees and/or Private Developer Partner. • Town of Vail enters into Joint Development Agreement specifying investment and equity stake of the partners. • Town of Vail may choose Development Agreement with a for- profit or non-profit developer to complete the project, equity investment for an ROI to the Developer. • The Red Sandstone Development is an example of this approach to funding. Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option.1 Pros & Cons Pros: • Reduces financial risk to Town of Vail with equity investments • Shared risk among Joint Venture Partners • Private sector experience to manage risk • Timely implementation driven by private sector profit • Knowledge of market, and financing community Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 3: Pros & Cons Cons: • Feasibility of enlisting Joint Venture Partners, i.e., are there willing partners to be had • Project can go awry if mission and goals of the partners are not aligned • Town of Vail relinquishes some control to joint venture partners and/or developer partner • For-profit "culture" vs. community's affordable housing priorities • Private Developer Partner could withdraw if financing gap increases during implementation • Clear Joint Venture and/or development agreement defining partner roles takes time 1/5/2016 Option 4: Private Development Funding Key Points: • Town of Vail subdivides site and transfers parcels to private sector • Parcels could be: — the duplex parcel along Chamonix Lane — the townhome parcel along Chamonix Road — the multi -family parcel along Chamonix Road — a fourth parcel of free market lots could also be platted Parcels would be sold with the stipulation that the parcels be deed restricted and developed as affordable housing with zoning controls. • Deed Restrictions could be used to differentiate among the income levels: — Residency Restriction only — Employment in the Town of Vail — Employment in eagle County (30+ hours per week) • Proceeds from sale free market lots help subsidize the affordable unit development. • Financial incentives necessary to entice private sector to address affordability gap • The Lion's Ridge Apartment Development is an example that closely mirrors this approach. Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option 4: Pros & Cons Pros: • Eliminates/reduces financial risk to town through private funding • Private sector expertise - market and construction techniques • Financial incentives can be less costly than direct investment Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option.4: Pros & Cons Cons: • Town loses ownership of land upon sale • Risk of not accomplishing affordability goals increases • Profit margin may limit ability to fill the affordability gap • Need for financial/regulatory incentives may outweigh risk of direct investment • Developers not accustomed to producing housing for lower AMI levels • Private financing for deed -restricted units may be difficult to obtain Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Key Considerations Option 1- 100 % Town of Vail Funding: • Financial Capacity, Risk Tolerance, Staff Capacity, Phasing • More Control = More Risk Option 2 - Government Funding Programs: • No 100% financing, Regulatory Compliance, Timing • Slightly Less Control (regs.) = Only Slightly Less Risk Option 3 - Joint Venture: • Willing Partners, Agreement Negotiations, Timing • Considerably Less Control = Relatively Less Risk Option 4 - Private Development Funding: • Ownership, Affordability Goals, Financial Incentives • Least Direct Control = Least Financial Risk Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Tolerance of Risk and Affordability? Option 4 Option 3 Private Development Joint Venture Funding Option 4 Private Development Funding Option 3 Joint Venture Town of Vail I Community Development 1/5/16 Option 2 Government Funding Option 1 ToV funding alone Option 2 Option 1 Government ToV funding alone Funding 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four funding options in order to effectively evaluate the options and select a preferred approach? 2. What is the Town Council's tolerance for financial risk and desired level of investment? Town of Vail I Community Development 1/5/16 0 TOWN OF VAIL"' 1/5/2016 Pending Policy Decisions: LJ Development Approach (12/15 & 1/19) U Funding Options (1/5 & 2/2) U Target Market (Special Meeting) LJ Subsidy Policy (1/5 & 2/2) LJ Cost/Pricing Strategy (1/5 & 1/19) LJ Deed Restriction Policy (2/2 & 2/16) U Final Project Proposal (3/15) LJ Construction Phases (4/19) LJ Phase 1 Infrastructure Contract Award (1/19) Town of Vail I Community Developments 1/5/16 1/5/2016 TOWN OF VA TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Discussion of Pricing Strategy Options for the Chamonix housing development. PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the alternative pricing strategies for the Chamonix Development and provide direction on next steps, and provide feedback on the following: . What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? . What range of income diversity does Town Council want to include in the development? . What is the Town Council's level of comfort in subsidizing the Chamonix development? BACKGROUND: The Town has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the pricing strategy. That decision point will need to occur before the end of the first quarter of 2016. ATTACHMENTS: Staff Memorandum PPT Presentation 1/5/2016 0) VAIL 1 Memorandum To: From: Date: Subject Vail Town Council Community Development Department January 5, 2016 An Overview of Pricing Strategy Options PURPOSE Town staff was instructed to propose and present pricing strategy options for the Chamonix Development for the Vail Town Council's review and consideration. The purpose of this public hearing is for the Town Council to review the various options and provide staff guidance on next steps in selecting a preferred pricing strategy alternative, or provide feedback on the following: What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? What range of income diversity does Town Council want to include in the development? What is the Town Council's level of comfort in subsidizing the Chamonix development? PRICING STRATEGY OPTIONS The Town has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the pricing strategy. That decision point will need to occur before the end of the first quarter of 2016. Option 1: Units Priced based upon Cost of Construction Key Points: • Recover the cost of construction. • Town of Vail recoups full investment in development • Only method to achieve affordability is through cost containment • Limited ability to contain cost equates to limited variability in price of units based upon square footage 1/5/2016 Maintain ownership through land lease The Arosa Duplex is an example of this approach to pricing: o Town continues to own the land; o There is a $25 per year 99 -year Land Lease with each owner; o The two units were built and sold to qualified owners for the cost of development; o The units were priced in the low $400 thousands. Pros: 1. Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units 2. Town of Vail recoups investment, therefore assumes less financial and sales risk 3. Prices set based on cost not market or affordability 4. Town of Vail may change parameters in effort to adjust cost and manage affordable pricing 5. Town of Vail maintains ownership of the land to ensure affordability over time Cons: 1. Pricing based strictly on cost leaves less room for diversity of incomes, i.e., the higher the cost of construction, the higher the per square foot price 2. Only way to adjust pricing is size and/or quality of units 3. Financial and political risk falls on Town of Vail Option 2: Units priced based upon cost with limited subsidy Key Points: • The sales price of the units is based upon the cost of construction minus some amount of subsidy not to include direct subsidy of construction. o A direct subsidy of construction would entail investing larger sums to reduce the cost of labor and materials in order to reduce pricing • Examples of other direct subsidies include: o Donating the land into the development o Donating the cost of infrastructure into the development • Examples of indirect subsidies include: o Deferring or forgiving all or a portion of development fees o Deferring tap fees o Land lease to reduce cost of development and defer land cost over time. • Determine if direct or indirect subsidies or some combination of the two will be used. • Determine what level of subsidy is warranted or acceptable to achieve desired goals. • If donated, Town of Vail does not recoup cost of land or infrastructure. • Cost of vertical construction becomes the determining factor for affordability. • The Red Sandstone Development is an example of this approach to pricing. o The Red Sandstone Townhome Development was a joint venture with the Eagle River Water & Sanitation District (ERW&SD) to create Employee Housing; Town of Vail Page 2 1/5/2016 o The pricing for the units was determined on the total cost of construction; o The land was donated into the deal by both joint venture partners and; o A zero interest construction loan was provided to construct the units at cost plus 6% (developer fee); o These units are priced today at $175,000 to $295,000. Pros: 1. Town of Vail reduces cost of development through manageable investment resulting in more affordable pricing 2. Town of Vail may change parameters in effort to adjust cost and manage affordable pricing 3. Pricing based on cost with a small subsidy leaves more room for diversity of incomes and affordability 4. Town of Vail maintains ownership of the land to ensure affordability over time Cons: 1. Town of Vail assumes a little more financial and sales risk 2. Financial and political risk falls on town alone 3. Cost of construction may still hamper the affordability of the units 4. Town of Vail doesn't recoup initial investment in Land & Infrastructure Option 3: Units Priced bV Deed Restriction Type Key Points: • The sale of unrestricted free market units/lots brings additional revenue to the development. • Seek private sector development partner for equity investment and market knowledge. • Live/Work Market Units are deed restricted to residency only (RO) and/or employment with higher prices, brining additional revenue to the development. • Affordable units would be restricted to those who have full-time employment in Valley (30+ hours per week) and the units would have price appreciation caps. • There is no example of this pricing strategy that was ever used in Vail. However, the most recent Town of Frisco EHU Development Peak One is a good example: o There were two basic subsidies by the Town - land under the development and the infrastructure were donated; o The mix of units and variety of sizes allowed diversity of income levels; ■ Ranged from 950 sq. ft. cottages to 4,900 sq. ft. single family; o A third subsidy to the project were the Live/Work Market Units for homeowners work in Summit County but have no income or appreciation limits; ■ These higher priced units were used to help offset the cost of the more affordable units. Town of Vail Page 3 1/5/2016 Pros: 1. Prices may be set based on cost with more affordability and diversity of incomes due to increase in subsidies 2. Market units help to lower subsidies required from Town of Vail 3. Variety of Deed Restriction Types widens range of market demand 4. Reduces financial risk to town with equity investment Cons: 1. Level of subsidies may not be sufficient to allow wide enough range of incomes 2. If subsidies are insufficient, pricing may be subject to size & quality of product for lower AMI income levels 3. Town may not recoup all of initial investment in land and infrastructure Option 4: Units Priced based upon Ability to Pay (Income Based) Key Points: • Requires determination of range of incomes desired o Calculate the Affordability Gap at each level of income o Calculate subsidies needed for each level • Requires sizable investment to provide adequate subsidies. • The cost of construction is calculated to meet the ability of the families at a variety of AMI levels to afford the sales price. • Cost of construction, unit size, or unit mix are not factors. • There is no example of this pricing strategy that was ever used in Vail. However, an Aspen Development, Burlingame offers some key insights to consider: o Aspen established a series of income categories that are used to determine sale prices; o Area Median Income (AMI) is used to define the categories; o Size Standards are typically used to match households with available homes, e.g. single -person HH with studio or one -bedroom o Prices were set to meet affordability within categories of income; o Presales were used to determine demand ■ Flexibility to change unit mix and size to meet demand was built into sales/subsidy model ■ Initial estimates of upper income category demand were overly optimistic ■ Actual demand tended towards the mid to lower end of the income categories o Significant funding was used to subsidize the project Pros: 1. Prices set are not based on cost with much more affordability and diversity of incomes 2. Affordability Gap to buy homes in Vail for typical working families is reduced considerably 3. More families can afford to live in Vail Town of Vail Page 4 1/5/2016 Cons: 1. Town assumes more financial and sales risk with additional subsidies required. 2. Political risk falls on town for levels of subsidy. 3. Private sector partner profit margin may limit ability to fill the affordability gap 4. Sales of free market units/lots, if used may only subsidize a portion of Town investment 5. Town may be subsidizing the cost of construction to establish this pricing III. STAFF RECOMMENDATION The Community Development Department requests the Vail Town Council consider the alternative pricing strategies for the Chamonix Development and provide direction on next steps, or provide feedback on the following: What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? What range of income diversity does Town Council want to include in the development? What is the Town Council's level of comfort in subsidizing the Chamonix development? Town of Vail Page 5 1/5/2016 Chamonix "Nail's newest residential neighborhood for families."' "...growing a thriving and balanced community" Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF 0 VA Purpose: 0 0 0 0 Background Project Guidelines and Goals Presentation of Pricing Strategy Options —Town's Role — Pros & Cons Schedule Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Project Guidelines and Goals: Optimize site for workforce for -sale housing (15 - 25 du's per acre) Context Sensitive Design Solution Phased Approach Desirable, marketable and diverse housing products Maximize limited financial resources Build responsibly considering topography and natural features Diversified cost/sales structure Town of Vail I Community Development 1/5/16 - Vail Town Council, April 2015 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? 2. What unit mix and product types does Town Council envision for the site? 3. What level of Income diversity does Town Council want to include in the project? 4. What levels of subsidy is Town Council willing to consider? Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Tolerance of Risk and Control? Option 1 Units Priced at Cost with Price Appreciation Caps Option 1 Units Priced at Cost with Price Appreciation Caps Option 2 Units priced at cost with limited subsidies Option 2 Units priced at cost with limited subsidies Town of Vail I Community Development 1/5/16 Option 3 Units Priced by Size & Product Type, Inc. FM Option 3 Units Priced by Size & Product Type, Inc. FM Option 4 Units Priced to Meet Income Needs Option 4 1 Units Priced to Meet Income Needs 1/5/2016 0 rowN of va Option 1: Units Priced based upon Cost of Construction Key Points: • Recover the cost of construction. • Town of Vail recoups full investment in development • Only method to achieve affordability is through cost containment • Maintain ownership through land lease • Limited ability to contain cost equates to limited variability in price of units • The Arosa Duplex is an example of this approach to pricing 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Optionj: Pros & Cons Pros: • Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units • Town of Vail recoups investment, assumes less financial and sales risk • Prices may be set based on cost not market or affordability • Town of Vail may change parameters in effort to adjust cost and manage affordability • Town maintains ownership of the land to ensure affordability Cons: • Pricing based strictly on cost leaves less room for diversity of incomes • Only way to adjust pricing is size and/or quality of units • Financial and political risk falls on town Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 2: Units priced based on cost with limited subsidies Key Points: • Price based upon construction cost minus some subsidy (not to include direct subsidy of construction). — Direct subsidy of construction entails investing much more to reduce the cost of labor and materials to reduce pricing • Examples of other direct subsidies include: — Donating the land into the development — Donating the cost of infrastructure into the development • Examples of indirect subsidies include: — Deferring or forgiving all or a portion of development fees — Deferring tap fees — Land lease to defer land cost over time. • Determine if direct or indirect subsidies or some combination of the two will be used. Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 2: Units priced based on cost with limited subsidies Key Points: • Determine level subsidy warranted or acceptable to achieve desired goals. • Town of Vail does not recoup cost of land or infrastructure, if donated. • Cost of vertical construction becomes the determining factor for affordability. • The Red Sandstone Development is an example of this approach topricing. p pp Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 2: Pros & Cons Pros: • Town of Vail reduces cost of development through manageable investment resulting in more affordable pricing • Town of Vail may change parameters in effort to adjust cost and manage affordable pricing • Pricing based on cost with a small subsidy leaves more room for diversity of incomes and affordability • Town of Vail maintains ownership of the land to ensure affordability over time Cons: • Town of Vail assumes a little more financial and sales risk • Financial and political risk falls on town alone • Cost of construction may still hamper the affordability of the units • Town of Vail doesn't recoup initial investment in Land & Infrastructure 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 3: Units Priced bV Deed Restriction Type Key Points: • The sale of unrestricted Free Market Units/Lots brings additional revenue to the development. • Seek private sector development partner for equity investment and market knowledge. • Live/Work Market Units are deed restricted to residency only (RO) and/or employment with higher prices, brining additional revenue to the development. • Affordable units would be restricted to those who have FT Employment in Valley (30+ hours per week) and the units would have price appreciation caps. • No example of this pricing strategy was ever used in Vail. A recent Town of Frisco EHU Project Peak One is a good example 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 3: Pros & Cons Pros: • Prices may be set based on cost with more affordability and diversity of incomes due to subsidies • Market units help to lower subsidies required from Town of Vail • Variety of Deed Restriction Types widens range of market demand • Reduces financial risk to town with equity investment Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option.1 Pros & Cons Cons: • Level of subsidies may not be sufficient to allow wide enough range of incomes • If subsidies are insufficient, pricing may be subject to size & quality of product for lower AMI income levels • Town of Vail may not recoup all of initial investment in land and infrastructure • Town of Vail relinquishes control to developer Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 4: Units Priced based upon Ability to Pay Key Points: • Requires determination of range of incomes desired — Calculate the Affordability Gap at each level of income — Calculate subsidies needed for each level • Requires sizable investment to provide adequate subsidies. • The cost of construction is calculated to meet the ability of the families at a variety of AMI levels to afford the sales price. • Cost of construction, unit size, or unit mix are not factors. • No example of this pricing strategy that was ever used in Vail. an Aspen project Burlingame offers some key insights to consider. Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" C)Dtion 4: Pros & Cons Pros: • Prices set are not based on cost with much more affordability and diversity of incomes • Affordability Gap to buy homes in Vail for families is reduced considerably • More families can afford to live in Vail Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va C)Dtion 4: Pros & Cons Cons: • Town assumes more financial and sales risk with additional subsidies required. • Political risk falls on town for levels of subsidy. • Private sector partner profit margin may may limit ability to fill the affordability gap • Sales of Free Market units/lots, if used may only subsidize a portion of Town investment • Town may be subsidizing the cost of construction to establish this pricing 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Key Considerations Option 1- Units Priced based upon Cost of Construction : • Recoup Investment, Affordability Gap, Cost Containment, • Less Affordable = Less Risk Option 2 — Prices Based upon Cost Minus Limited Subsidies: • Doesn't Recoup 100%, Some Affordability, Vertical Construction Cost Determining Factor • Some Affordability = Some Additional Risk Option 3 - Include Free Market Units/Lots to Subsidize Project: • May Recoup More, Additional Subsidies, More Affordable • More Affordable = More Risk Option 4 - Prices Based on Ability to Pay : • Higher Investment, Affordability Goals, Most Financial Risk • Most Affordable = Most Risk Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Tolerance of Risk and Affordability? Option 1 Cost of Construction Option 1 Cost of Construction Option 2 Cost Minus Limited Subsidies Option 2 Cost Minus Limited Subsidies Town of Vail I Community Development 1/5/16 Option 3 Deed Restriction Type Option 4 Ability to Pay Option 3 Option 4 Deed Ability to Pay Restriction Type 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four pricing strategies in order to effectively evaluate the options and select a preferred approach? 2. What unit mix and product types does Town Council envision for the site? 3. What level of Income diversity does Town Council want to include in the project? 4. What levels of subsidy is Town Council willing to consider? Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Pending Policy Decisions: LJ Development Approach (12/15 & 1/19) U Funding Options (1/5 & 2/2) U Target Market (Special Meeting) LJ Subsidy Policy (1/5 & 2/2) LJ Cost/Pricing Strategy (1/5 & 1/19) LJ Deed Restriction Policy (2/2 & 2/16) U Final Project Proposal (3/15) LJ Construction Phases (4/19) LJ Phase 1 Infrastructure Contract Award (1/19) Town of Vail I Community Developments 1/5/16 1/5/2016 TOWN OF VA Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Discussion of the various Subsidy Options to consider for the Chamonix housing development. PRESENTER(S): Alan J. Nazzaro, Housing Manager ACTION REQUESTED OF COUNCIL: The Community Development Department requests the Vail Town Council consider the alternative subsidy policies for the Chamonix Development and provide direction on next steps, and provide feedback on the following: . What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? . What level of Income diversity does Town Council want to include in the development? What levels of subsidy is Town Council willing to consider? BACKGROUND: Real estate in the Town of Vail remains largely out of the purchasing power for most employees earning their income in Eagle County. To increase the affordable housing opportunities for employees living in town, the Vail Town Council has purchased and master planned what is commonly referred to as the Chamonix Development for deed restricted employee housing. The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the Subsidy Policies. That decision point will need to occur before the end of the first quarter of 2016. ATTACHMENTS: Staff Memorandum PPT Presentation 1/5/2016 rowN ofvain Memorandum To: Vail Town Council From: Community Development Department Date: January 5, 2016 Subject: An Overview of Subsidy Policy Options I. PURPOSE Town staff was instructed to propose and present subsidy policy options for the Chamonix Development for the Vail Town Council's review and consideration. The purpose of this public hearing is for the Town Council to review the various options and provide staff guidance on next steps in selecting a preferred subsidy policy alternative, or provide feedback on the following: What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? What level of Income diversity does Town Council want to include in the development? What levels of subsidy is Town Council willing to consider? II. INTRODUCTION Real estate in the Town of Vail remains largely out of the purchasing power for most employees earning their income in Eagle County. To increase the affordable housing opportunities for employees living in town, the Vail Town Council has purchased and master planned what is commonly referred to as the Chamonix Development for deed restricted employee housing. The Town Council must consider what, if any, subsidy it will require to ensure the units are occupied by those residents. In 2015, Town Council affirmed a number of goals for the Chamonix Development to include: • Optimize the use of the site for workforce for -sale housing (15 - 25 DU's per acre) 1/5/2016 • Design a context sensitive design solution (design review guidelines) • Ability to be phased over time (min. two phases) • Deliver desirable, marketable and diverse types of housing products (duplexes; one, two & bedroom flats; townhomes, etc.) • Maximize the town's limited supply of financial resources • Build responsibly given the existing site configuration, topography and natural features of the site • Develop a diversified cost/sales structure to respond to a wider range of buyers (i.e., pricing structure based upon income) In addition to these goals, the Master Plan also stated that the target group for the Chamonix development was families. The target income group was determined to fall within 60-120% of the Area Median Income {AMI) range for Eagle County, with a possible inclusion of incomes up to 140% of AMI. Staff was directed to prepare options for a subsidy policy to ensure the widest possible range of buyers. To do this we had to take into consideration the "Affordability Gap": The home purchase "affordability gap" (AG) is defined as the difference between the price that the average household can afford to pay for a home and the median price of housing on the market. Another indication of the lack of affordability in a given community is determined by calculating the Housing Affordability Index (HAI). o The HAI measures whether or not a typical family could qualify for a mortgage loan on a typical home. o The typical family is defined as one earning the median family income as reported by the U.S. Bureau of the Census. o The prevailing mortgage interest rate is the effective rate on loans closed on existing homes from the Federal Housing Finance Board. o A value of 100 means that a family with the median income has exactly enough income to qualify for a mortgage on a median -priced home, assuming a 20 percent down payment. o An increase in the HAI, then, shows that this family is more able to afford the median priced home. For example: • The median price for a home in Vail proper jumped to $1.4 million, in the second quarter of this year. • The median income for a family of four for Eagle County for 2015 was $86,200 • The Affordability Index for Vail equals approximately 32 o Which means the typical family needs to earn more than three times their current income to be able to afford the typical Free Market home in this community. • The corresponding affordability gap is: o $1.4 million - $320,000* = $1.08 million *The maximum price affordable to the typical family which was calculated for $86,200 in income Town of Vail Page 2 1/5/2016 III. SUBSIDY POLICY OPTIONS The Town of Vail has invested time, money and resources to bring the Chamonix Development to fruition and now stands on the threshold of breaking ground. Before moving forward a decision must be made on the Subsidy Policies. That decision point will need to occur before the end of the first quarter of 2016. Option 1: Zero Subsidy Key Points: • Assumes that the Affordability Gap can be met when units are sold to recoup total cost of development. • Town of Vail recoups investment in site development and cost of construction. • It is difficult to fill affordability gap, if cost control is the only method achieving desired sales prices, due to the high cost of the land, infrastructure and vertical construction. • This policy doesn't take into account the construction cost differential in Vail versus down valley. • Less density means higher per unit costs equals less affordability. • Vail Commons is an example of this approach: o Town of Vail continues to own the land; o There is a 99 -year Land Lease with the HOA; o There were 53 condominium units built in the residential portion and sold to qualified owners for the cost of development; o Price -capped with a 3% cap on appreciation and a limit of 10% for allowed capital improvements; o The only subsidy into the deal was a long-term land lease on the property at 99 years for the residential portion to be paid back by the corresponding HOA, which is included in the fees on each unit. o Two factors of deed restriction and price capping at the levels stated above combined with the initial lower cost of construction created and helped maintain affordability; o These units always garner the maximum allowed appreciation price upon resale. Pros: 1. Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units 2. Town of Vail assumes less financial and sales risk by recouping investment in site development and construction cost; 3. Town of Vail maintains ownership of the land to help ensure affordability Cons: 1. No subsidy leaves less room for pricing for a diversity of incomes 2. Affordability is diminished with prices based on cost, since land and construction costs in Vail are so high Town of Vail Page 3 1/5/2016 3. Only way to address affordability is size and/or quality of units 4. Financial and political risk falls on town 5. Risk management in housing sales is not in purview of local government Option 2: Limited Subsidies Key Points: • Assumes that the Affordability Gap can only begin to be met when units are sold with a subsidy that is somewhere less than the total cost of development. • Town of Vail does not recoup the cost of land or infrastructure improvements donated. • This policy begins to address the affordability gap for families; o Does this level of subsidy address the desired levels of income for the development? • This policy acknowledges the high cost of land and infrastructure, then lets vertical construction cost be the determining factor for affordability. • The Red Sandstone Development is an example of this approach to pricing. o The pricing for the units was determined on a square footage basis from the total cost of construction divided by the total square footage and assigned to each unit; o The land was donated into the deal by both Joint Venture Partners and; o A zero interest construction loan was made to the Developer to construct the units at cost plus 6% (developer fee). Pros: 1. Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units 2. Prices set based on cost of vertical construction with a little more affordability 3. Pricing based on cost with a small subsidy leaves more room for diversity of incomes 4. Town of Vail maintains ownership of the land to ensure affordability Cons: 1. Town of Vail doesn't recoup land or infrastructure investment, thereby assumes a little more financial and sales risk 2. Financial and political risk associated with increased subsidies 3. Cost of construction may still hamper the affordability of the units 4. Risk management in housing sales is not in purview of local government Option 3: Include Free Market Units/Lots to Subsidize Project Key Points: • The sale of unrestricted Free Market Units/Lots brings additional subsidies to the development. Town of Vail Page 4 1/5/2016 • Seek private sector development partner for equity investment and market knowledge. • Live/Work Market Units are deed restricted to residency only (RO) and/or employment with fewer subsidies, brining additional revenue to the development. • Affordable units would be restricted to those who have Full-time Employment in Valley (30+ hours per week) and the units would have price appreciation caps. • There is no example of this subsidy policy that was ever used in Vail. However, the most recent Town of Frisco EHU Project Peak One is a good example: o There were two basic subsidies by the Town - land under the development and the infrastructure were donated; o The mix of units and variety of sizes allowed diversity of income levels ■ Ranged from 950 sq. ft. Cottages to 4900 sq. ft. Single Family; o A third subsidy to the project was the Live/Work Market Units for homeowners work in Summit County but have no income or appreciation limits; ■ These higher priced units were used to help offset the cost of the affordable units. Pros: 1. Town of Vail may recoup some investment through sale of free market units 2. Prices may be set based on cost with more affordability and diversity of incomes due to increase in subsidies 3. Free Market units help to lower subsidies required from Town of Vail 4. Reduces financial risk to town with equity investment by private sector 5. Private sector experience to manage risk Cons: 1. Town of Vail relinquishes control to developer 2. Private sector partner profit margin may conflict with affordability gap resulting from cost of construction 3. Private sector partner could withdraw if financing gap increases during implementation 4. Clear development agreement defining partner roles takes time 5. Town of Vail may not recoup initial investment in Land & Infrastructure Option 4: Subsidies Based on Ability to Pay Key Points: • Need to determine range of incomes to be represented in the development. • Need to calculate levels of subsidies required to make units affordable to families at various income levels. • The cost of construction is subsidized, so prices are set to meet the ability of the families at a variety of AMI levels to afford the sales price. • Costs of construction, unit size, or unit mix are not factors. • There is no example of this subsidy policy that was ever used in Vail. However, an Aspen Development, Burlingame offers some key insights to consider: Town of Vail Page 5 1/5/2016 o Aspen established a series of income categories that are used to determine sale prices; o Area Median Income (AMI) is used to define the categories; o Size Standards are typically used to match households with available homes, e.g. single -person HH with studio or one -bedroom o Prices were set to meet affordability within categories of income; o Presales were used to determine demand Flexibility to change unit mix and size to meet demand was built into sales/subsidy model Initial estimates of upper income category demand were overly optimistic Actual demand tended towards the mid to lower end of the income categories o Significant funding was used to subsidize the project Pros: 1. More families can afford to live in Vail 2. Affordability Gap to buy homes in Vail is reduced considerably 3. Prices set are not based on cost with much more affordability and diversity of incomes possible 4. Maximizes benefit of investment across spectrum of households rather than restricting access to higher income households Cons: 1. Town of Vail assumes more financial and sales risk with additional subsidies required. 2. Political risk falls on town for levels of subsidy. 3. May not attract families in higher target income ranges III. STAFF RECOMMENDATION The Community Development Department requests the Vail Town Council consider the alternative subsidy policies for the Chamonix Development and provide direction on next steps, or provide feedback on the following: What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? What level of Income diversity does Town Council want to include in the development? What levels of subsidy is Town Council willing to consider? Town of Vail Page 6 1/5/2016 Chamonix "Nail's newest residential neighborhood for families."' "...growing a thriving and balanced community" Town of Vail I Community Development 1 1/5/16 1/5/2016 TOWN OF 0 VA Purpose: 0 0 0 0 Background Project Guidelines and Goals Presentation of Subsidy Policy Options —Town's Role — Pros & Cons Schedule Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Project Guidelines and Goals: Optimize site for workforce for -sale housing (15 - 25 du's per acre) Context Sensitive Design Solution Phased Approach Desirable, marketable and diverse housing products Maximize limited financial resources Build responsibly considering topography and natural features Diversified cost/sales structure Town of Vail I Community Development 1/5/16 - Vail Town Council, April 2015 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? 2. What level of Income diversity does Town Council want to include in the project? 3. What levels of subsidy is Town Council willing to consider? Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Tolerance of Risk and Affordability? Option 1 Option 2 Low or Zero Subsidy Limited Subsidies Option 1 Low or Zero Subsidy Option 2 Limited Subsidies Town of Vail I Community Development 1/5/16 Option 3 Include Free Market Units/Lots to Subsidize Project Option 3 Include Free Market Units/Lots to Subsidize Project Option 4 Subsidies Set to Meet Income Needs Option 4 Subsidies Set to Meet Income Needs 1/5/2016 0 rowN of va Option 1: Zero Subsidy Key Points: • Assumes that the Affordability Gap can be met when units are sold to recoup total cost of development • Town of Vail recoups investment in site development and cost of construction. • It is difficult to fill affordability gap, if cost control is only method to achieve pricing. • Policy doesn't take into account the construction cost differential in Vail versus down valley. • Less density means higher per unit costs equals less affordability. • Vail Commons is a close example of this approach Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 1: Pros & Cons Pros: • Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absoration of units • Town of Vail assumes less financial and sales risk by recouping investment in site development and construction cost; • Town of Vail maintains ownership of the land to help ensure affordability 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 1: Pros & Cons Cons: • No subsidy leaves less room for pricing for a diversity of incomes • Affordability is diminished with prices based on cost, since land and construction costs in Vail are so high • Only way to adjust affordability is size and/or quality of units • Financial and political risk falls on town • Risk management in housing sales is purview of local government Town of Vail I Community Development 1/5/16 1/5/2016 not in 0 rowN of va Option 2: Limited Subsidies Key Points: • Assumes Affordability Gap can begin to be met with units sold at a subsidy less than the total cost of development. • Town of Vail does not recoup the cost of land or infrastructure improvements donated. • Policy begins to address the affordability gap for families; — Does this level of subsidy address the desired levels of income for the development? • Policy acknowledges the high cost of land and infrastructure, lets vertical construction cost be the determining factor for affordability. • The Red Sandstone Development is an example of this approach to pricing. 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option.2: Pros & Cons Pros: • Town of Vail has the flexibility to make necessary changes to adjust development parameters to increase absorption of units • Prices set based on cost of vertical construction with a little more affordability • Pricing based on cost with a small subsidy leaves more room for diversity of incomes • Town of Vail maintains ownership of the land to ensure affordability Cons: • Town of Vail doesn't recoup land or infrastructure investment, thereby assumes a little more financial and sales risk • Financial and political risk associated with increased subsidies • Construction Cost may still hamper the affordability of the units • Risk management in housing sales is not in purview of local government Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL"' Option 3: Include Free Market Units/Lots to Subsidize Project Key Points: • The sale of unrestricted Free Market Units/Lots brings additional subsidies to the development. • Seek private sector development partner for equity investment and market knowledge. • Live/Work Market Units are deed restricted to residency only (RO) and/or employment with fewer subsidies, brining additional revenue to the development. • Affordable units would be restricted to those who have Full- time Employment in Valley (30+ hours per week) and the units would have price appreciation caps. • There is no example of this pricing strategy that was ever used in Vail. However, the most recent Town of Frisco EHU Project Peak One is a good example Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option 3: Pros & Cons Pros: • Town of Vail may recoup some investment through sale of free market units • Prices may be set based on cost with more affordability and diversity of incomes due to increase in subsidies • Free Market units help to lower subsidies required from Town of Vail • Reduces financial risk to town with equity investment by private sector • Private sector experience to manage risk 0 Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL Option 3: Pros & Cons Cons: • Town of Vail relinquishes control to developer • Private sector partner profit margin may conflict with affordability gap resulting from cost of construction • Private sector partner could withdraw if financing gap increases during implementation • Clear development agreement defining partner roles takes time • Town of Vail may not recoup initial investment in Land &Infrastructure Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option 4: Subsidies Based on Ability to Pay Key Points: • Need to determine range of incomes to be represented in the development. • Need to calculate levels of subsidies required to make units affordable to families at various income levels. • The cost of construction is subsidized, so prices are set to meet the ability of the families at a variety of AMI levels to afford the sales price. • Costs of construction, unit size, or unit mix are not factors. • No example of this subsidy policy was ever used in Vail. An Aspen project, Burlingame is a good example. Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Option 4: Pros & Cons Pros: • More families can afford to live in Vail • Affordability Gap to buy homes in Vail is reduced considerably • Prices set are not based on cost with much more affordability and diversity of incomes possible • Maximizes benefit of investment across spectrum of households rather than restricting access to higher income households Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Option.4: Pros & Cons Cons: • Town of Vail assumes more financial and sales risk with additional subsidies required. • Political risk falls on town for levels of subsidy. • May not attract families in higher target income ranges Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Key Considerations Option 1 -Zero Subsidy: • Recoup Investment, Affordability Gap, Cost Differential, Size/Quality of Units • Less Subsidy = Less Affordable • Option 2 - Limited Subsidies: • Doesn't Recoup 100%, Some Affordability, Vertical Construction Cost Determining Factor • Some Subsidy = Some Affordability Option 3 - Include Free Market Units/Lots to Subsidize Project: • May Recoup More, Additional Subsidies, More Affordable • More Subsidy = More Affordable Option 4 - Subsidies Based on Ability to Pay • Higher Investment, Affordability Goals, Most Financial Risk • Most Subsidy = Most Affordable Town of Vail I Community Development 1/5/16 1/5/2016 TOWN OF VAIL" Tolerance of Risk and Affordability? Option 1 Zero Subsidy Option 1 Zero Subsidy Option 2 Limited Subsidies Option 2 Limited Subsidies Town of Vail I Community Development 1/5/16 Option 3 Include Free Market Units/Lots to Subsidize Project Option 3 Include Free Market Units/Lots to Subsidize Project Option 4 Subsidies Based Upon Ability to Pay Option 4 Subsidies Based Upon Ability to Pay 1/5/2016 0 rowN of va 1. What additional information does the Town Council need regarding the four subsidy policies in order to effectively evaluate the options and select a preferred approach? 2. What level of Income diversity does Town Council want to include in the project? 3. What levels of subsidy is Town Council willing to consider? Town of Vail I Community Development 1/5/16 1/5/2016 0 rowN of va Pending Policy Decisions: LJ Development Approach (12/15 & 1/19) U Funding Options (1/5 & 2/2) U Target Market (Special Meeting) LJ Subsidy Policy (1/5 & 2/2) LJ Cost/Pricing Strategy (1/5 & 1/19) LJ Deed Restriction Policy (2/2 & 2/16) U Final Project Proposal (3/15) LJ Construction Phases (4/19) LJ Phase 1 Infrastructure Contract Award (1/19) Town of Vail I Community Developments 1/5/16 1/5/2016 TOWN OF VA ►owx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Information Update: 1) November Sales Tax Report 2) Revenue Highlights 3) Random Acts of Kindness Program ATTACHMENTS: 2015 November Sales Tax Collections January 2016 Revenue Highlights Random Acts of Kindness Program 1/5/2016 MEMORANDUM December 28, 2015 To: Vail Town Council Stan Zemler Kathleen Halloran From: Sally Lorton Re: November Sales Tax estimate Vail will collect another $58,000 in November sales tax to bring collections to $981,567. If so, November will be down 3.4% or $34,490 from budget and up 2.0% or $19,223 from November 2014. Year to date would be up 2.3% or $474,545 from budget and up 5.6% or $1,118,330 from 2014. 1/5/2016 Month 2005 2006 2007 2008 2009 Town of Vail Sales Tax Worksheet 12/28/2015 2010 2011 2012 2013 2014 Budget 2015 Collections Budget Variance % Change from 2014 % Change from Budget January 2,275,967 2,597,985 2,783,306 2,976,655 2,619,673 2,564,383 2,795,688 2,855,524 3,145,620 3,483,245 3,525,333 3,695,800 170,467 6.10% 4.84% February 2,429,377 2,527,130 2,718,643 3,071,615 2,588,889 2,577,360 2,803,136 2,994,580 3,267,351 3,477,419 3,620,104 3,592,949 (27,155) 3.32% -0.75% March 2,785,101 2,852,954 2,986,446 3,327,304 2,504,567 2,685,004 3,143,418 3,185,859 3,650,157 3,788,185 3,949,005 4,052,963 103,958 6.99% 2.63% April 915,554 1,280,324 1,330,740 1,098,918 1,235,941 1,156,934 1,191,690 1,183,087 1,069,186 1,280,641 1,313,158 1,370,269 57,111 7.00% 4.35% May 458,770 449,283 545,874 622,103 516,150 421,925 473,292 487,739 563,602 607,729 616,645 583,794 (32,851) -3.94% -5.33% June 834,913 805,362 953,017 918,061 717,233 873,765 895,951 963,143 1,023,801 1,153,247 1,167,182 1,241,741 74,559 7.67% 6.39% July 1,166,183 1,255,243 1,265,781 1,397,842 1,121,860 1,228,767 1,481,329 1,573,499 1,654,161 1,829,102 1,879,577 1,937,034 57,457 5.90% 3.06% August 993,985 1,055,614 1,162,746 1,349,795 1,068,391 1,147,352 1,310,471 1,380,710 1,507,048 1,674,813 1,695,885 1,701,538 5,653 1.60% 0.33% September 795,807 832,549 908,318 834,569 753,754 761,425 889,945 978,037 994,135 1,054,015 1,124,778 1,232,176 107,398 16.90% 9.55% October 566,173 614,396 688,519 662,767 581,033 594,362 623,420 644,577 755,133 752,295 799,096 791,534 (7,562) 5.22% -0.95% November 713,117 799,582 747,877 719,109 651,873 701,075 788,430 825,873 947,627 962,344 1,016,057 923,567 (92,490) -4.03% -9.10% Total 13,934,947 15,070,422 16,091,267 16,978,738 14,359,364 14,712,352 16,396,770 17,072,628 18,577,821 20,063,035 20,706,820 21,123,365 416,545 5.28% 2.01% December 2,549,032 2,771,258 2,821,871 2,652,628 2,553,974 2,963,763 3,184,645 2,973,826 3,422,178 3,818,096 3,779,180 Total 16,483,979 17,841,680 18,913,138 19,631,366 16,913,338 17,676,115 19,581,415 20,046,454 21,999,999 23,881,131 24,486,000 1/5/2016 TOWN OF VAIL UPDATED REVENUE HIGHLIGHTS January 2, 2016 Sales Tax Upon receipt of all sales tax returns, November collections are estimated to be $981,567 up 2.0% from last year and down 3.4% compared to budget. Year to date collections of $21,181,365 are up 5.6% from the prior year and up 2.3% from budget. Inflation as measured by the consumer price index was up 0.5% for November. The annual budget totals $24.5 million. Real Estate Transfer Tax (RETT) RETT collections through December 28 total $6,042,641 down 11.8% from this time last year. 2014 annual collections totaled $6,849,449, a record year since the peak in 2008. The 2015 amended budget of $6,190,000 is a 9.6% reduction from prior year actuals. Construction Use Tax Use Tax collections through December 23 total $2,223,051 down 1.4% compared to $2,254,400 from this time last year. The annual budget totals $1.8 million. Summary Across all funds, year-to-date total revenue of $62.8 million is up 4.7% from the amended budget and up 7.3% from prior year, mainly due to increases in sales tax and construction related fees. 1/5/2016 Patty McKenny From: Aryn Schlichting Sent: Thursday, December 17, 2015 9:21 AM To: Dave Chapin; Dick Cleveland; Greg Moffet; Jen Mason; Jenn Bruno; Kevin Foley; Kim Langmaid; Patty McKenny; Stan Zemler; Suzanne Silverthorn; Tammy Nagel Subject: Council Members: Join us for Random Acts of Kindness Attachments: Program Details - Random Acts of Kindness .pdf Dear council members, As you may have heard, we are launching a new program called Random Acts of Kindness as a fun way encourage & empower our employees to interact with guests. Each employee will have cards to hand out to guests that offer a free cup of coffee/hot chocolate to a local establishment. Please see the attached program details. We would love to have you participate in the program as well! How do you participate? Your RAK (random acts of kindness) cards will be available in your mailbox/folder (by Tammy's desk) on Friday Dec 18th. These cards will be replenished each month and placed with your paycheck. You may choose to give them out to guests at anytime or wait for the special "RAK" days when many Town of Vail office employees will be hitting the village to surprise and delight our guests with a card for free hot drink! Please let myself of Suzanne know if you have any questions. Thank you! Aryn Schlichting HR Professional / Recruiter Human Resources TOWN OF VAIL 970.479.2118 aschlichtina(c)vailaov.com vailgov.com twitter.com/vailgov ®Y t 4��41 Follow us on Linked In... 1/5/2016 RANDOM � Program Details ACTS OF 1 Each department will receive a stack cards, offering a free hot KINDNESS drink to a guest of their choice. Cards will be distributed monthly with paychecks (2-3 cards per employee). The first will be available from your supervisor on Dec 18. Groups wishing to participate on scheduled days can join us on the following dates: Wednesday, Dec 23rd (distributed on 12/18) Thursday, Jan 21st (distributed on 1/15) Wednesday, Feb 17th (distributed on 2/12) Saturday, Mar 12th (distributed on 3/11) Monday, Apr 4th (distributed 3/25) 2 How do I participate? Office employees will be encouraged to get out of the office on RAK days, where others may choose to give out their cards over the course of the month. Interested in joining the environmental deptartment hand out reusable bags on Dec 23rd? Contact Mark, environmental coordinator, at Mhoblitzell c@vailgov com. With these cards we encourage you to be on the look out for these three types of situations... Reward You notice a guest holding the door open for another guest, or picking up trash, recycling, and carpooling. Surprise & Totally random! Maybe you decide the next person who walks across the Delight bridge, or the next person who walks into the library. You just want to "make someone's' day„. Recovery Recovery — guest is having a bad day. Crying kids, lost car, pass is closed. This does not replace current standard procedures of helping a guest. Simple steps to handing out the card Introduce Name and where you work. Explain How is your trip so far? We hope to make it a little better by offering you a warm drink! Liste n If they ask for advice. Follow up. Thank Thank the guest for visiting Vail and invite them back! Share! Tell us your story by completing a Random Act of Kindness form (attached) and emailing to kindness c@vailgov.com or dropping it at HR. Winners will be selected at random each month for a prize. 1/5/2016 Patty McKenny From: Aryn Schlichting Sent: Wednesday, December 23, 2015 8:14 AM To: Everyone Subject: TODAY: Random Acts of Kindness (make someone smile) Attachments: Random Acts of Kindness Form - Dec 15.pdf Today is a Random Acts of Kindness day! Take a minute to put a smile on a guests face by offering them a FREE hot drink. We've heard the kids are going crazy over the hot chocolates0 Please remember to share your story with us! See attached. Have a happy & safe holidays — from the RAK team Aryn Schlichting HR Professional / Recruiter Human Resources 0- TOWN Of VAIL 970.479.2118 aschlichtina5..vailoov.com vailaov.com twitter.com/vailgov Follow us on Linked In... 1/5/2016 Employee Name: RANDOM Department: ACTS OF Date: KINDNESS Cards will be distributed monthly to your department. Groups wishing to participate on scheduled days can join us on the following dates: Wednesday, Dec 23rd (distributed on 12/18) Thursday, Jan 21st (distributed on 1/15) Wednesday, Feb 17th (distributed on 2/12) Saturday, Mar 12th (distributed on 3/11) Monday, Apr 4th (distributed 3125) We want to hear from you! Share your Random Acts of Kindness story in at least tMW categories below to be eligible for the monthly participation raffle. Reward You notice a guest doing a good deed (ex. holding the door open for another guest, or picking up trash, recycling, and carpooling). Guest: Date: Story: 2 Surprise & Select a guest at random! Maybe you decide the next person who walks delight across the bridge, or the next person who walks into the library. You just want to umake someone's day". Guest: Story: Date: 3 Recovery You see a guest having a bad day (ex. crying kids, lost car, pass is closed). This does not replace current standard procedures of helping a guest. Guest: Story: Date: 16 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Matters from Mayor, Council and Committee Reports 1/5/2016 Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Executive Session, pursuant to: 1) C.R.S. §24-6-402(4)(a)(b)(e) - to discuss the purchase, acquisition, lease, transfer, or sale of property interests; to receive legal advice on specific legal questions; and to determine positions, develop a strategy and instruct negotiators, Regarding: City Market Land Lease PRESENTER(S): Matt Mire, Town Attorney 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Council will recess the meeting until 6:00 pm 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Citizen Participation begins at 6:00 pm 1/5/2016 ►owx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Consent Agenda 1) Minutes from December 1, 2015 meeting 2) Minutes from December 15, 2015 meeting 3) Resolution No. 1, Series of 2016, a Resolution Approving the Amendment to the Development Agreement Between the Town of Vail and Lion's Ridge Apartment Homes, LLC; and Setting Forth Details in Regard Thereto ATTACHMENTS: Minutes from December 1, 2015 meeting Minutes from December 15, 2015 meeting Resolution No. 1, Series of 2016 1/5/2016 Vail Town Council Meeting Minutes Tuesday, December 1, 2015 6:00 P.M. Vail Town Council Chambers The regular meeting of the Vail Town Council was called to order at approximately 6:00 P.M. by Mayor Dave Chapin. Members present: Dave Chapin, Mayor Jenn Bruno, Mayor Pro Tem Dick Cleveland Kevin Foley Kim Langmaid Jen Mason Greg Moffet Staff members present: Stan Zemler Matt Mire, Town Attorney Patty McKenny, Town Clerk The first item of business was Citizen Participation with comments as follows: Michael Letourneau, representing Solar Crest Condominium Association, presented some information about a recent situation between the Association and Town of Vail Community Development Department related to a "red tag" issed them because of a dumpster on town owned property. He noted they have been trying to comply with the recycling regulations to construct a new dumpster. After some discussion, it was noted town staff would work with the Association in an effort to ensure the appropriate process and compliance with the matter would result. Taylor Gardarian, Eagle County resident, presented additional information about his topic of the axiom of time related to his non profit organization Open Source. Mayor Chapin noted the topic did not come under appropriate town business. The second item of business was Proclamation No. 7, Series of 2015, Proclamation Declaring December 11, 2015 as "WhoVail Day". Jenn Bruno, Town Council, read the proclamation for the audience. Moffet moved to approve Proclamation No. 7 with a second by Foley and it was passed unanimously (7-0). The third item of business was the appointment of the Municipal Judge. Mayor Chapin noted the Town Charter (7.2) and Municipal Code (1-9- 6) address the appointment of a municipal judge for a two year term. Moffet moved to appoint Buck Allen to a two year term as Vail's Municipal Judge with the term to expire November 2017. Bruno seconded the motion and it passed unanimously (7-0). Judge Allen noted he has served 36 years with the Town of Vail. The fourth item of business was the Consent Agenda as follows: 1) Minutes from November 3, 2015 meeting Moffet moved to approve the minutes; Bruno seconded the motion and it was approved by those attending the meeting on that date (Bruno, Chapin, and Moffet — aye; Cleveland, Foley, Langmaid, and Mason abstained). Town Council Meeting Minutes of December 1, 2015 Page 1 1/5/2016 2) Minutes from November 17, 2015 meeting Cleveland moved to approve the minutes; Moffet seconded the motion and it passed unanimously (7-0). The fifth item on the agenda was the Town Manager's Report at which time there was mention of the Birds of Prey event happening in Beaver Creek this upcoming weekend. He also reported on the Gore Creek matter indicating the town would host a debrief of the matter with several private and public parties that week in order to follow up on details of what transpired and how to mitigate any further issues. The sixth item of business was a presentation by the Commission on Special Events with their (CSE) proposed funding allocations for 2016 Cultural, Recreational and Community Events and Education and Enrichment Programming. Barry Davis, Chairman, requested the Town Council approve the proposed funding allocations for the 2016 Cultural, Recreational and Community Events and the Educational and Enrichment Programming. They did share their support for a learning and multi -cultural facility for Vail. Chapin noted how far the Commission has come on developing the objectives and metrics of measuring the success of the events. After the presentation, there was a brief discussion about the fact that the Town Council was not required to approve the CSE budget, but rather the code indicates council members would "call up" and review funding allocations or CSE decisions if there were any questions or concerns. In summary, there was no need for any action but rather the process was one that is informational only. It was noted staff will continue to research and present the CSE with fresh ideas for events as well they continue to evaluate the calendar and when new opportunities might be scheduled, although it was noted a busy schedule already exists. Town Council thanked the Commission for their work and efforts with the event planning. There was a special thanks to Rayla Kundolf for her eight years of service with CSE. The seventh item on the agenda was second reading of Ordinance No. 16, Series 2015, an Ordinance providing for the levy assessment and collection of town property taxes due for the 2015 tax year and payable in the 2016 fiscal year as presented by Kathleen Halloran, Finance Director. The town is required by Colorado state law to certify the mil levy by December 15 of each year. Moffet moved to approve Ordinance No. 16 and Bruno seconded the motion. Chapin noted there was an update with the ordinance made related to using the most current assessed valuation number. There were no public comments on the ordinance. The motion passed (7-0). The eighth item on the agenda was first reading of Ordinance No. 17, Series 2015 an Ordinance making budget adjustments to the Town of Vail General Fund, Capital Projects Fund, Real Estate Transfer Tax Fund, and Timber Ridge Enterprise Fund. Several budget highlights were presented and in summary it was noted that across all funds, the supplemental budget request would adjust the budget to reflect $119,501 of additional revenue and proposes an increase of $360,252 to expenditures. General Fund Budgeted revenue adjusted by an increase of $106,962 which is directly offset by expenditures, corresponding expenditures outlined in budget memo. Adjustments to the General Fund 2015 budget result in a net decrease of $53.8K, with a resulting fund balance of $18.9 million by the end of 2015, or 54% of annual revenues. Town Council Meeting Minutes of December 1, 2015 Page 2 1/5/2016 Capital Projects Fund Budgeted revenue decreased by a total of $26,801 and includes a decrease in reimbursement from the Vail Reinvestment Authority by $80,548 to coincide with the project budgets that were adjusted earlier in the year offset by revenue increases of $53,747. The increased revenues are all reimbursements for expenditures, details outlined in the packet memo. The proposed budget adjustments will result in an estimated fund balance of $20.9 million by the end of 2015. Real Estate Transfer Tax (RETT) Fund Budgeted revenues reduced by a total of $26,810 which includes a $50K reduction in reimbursement from Vail Reinvestment Authority. This is related to council's decision to not move forward with a skate park snowmelt system previously budgeted. In addition, revenues will increase by $23,109 (with corresponding expenditure) for a recycling reimbursement from Eagle County. New projects or increases were outlined in the packet memo. The proposed budget adjustments result in an estimated fund balance of $4.4 million by the end of 2015. Timber Ridge Enterprise Fund Budgeted revenue will be increased by a total of $66K from increased projections in rental income mainly due to no vacancies during the year. Staff is also requesting to supplement 2015 expenses by a total of $49,994. Expenditure adjustments were detailed in the packet memo. The proposed budget adjustments result in an estimated fund balance of $717K by the end of 2015. Foley requested a review of transit ridership and personnel costs be made related to the increased service provided to Ford Park; Mason noted the increased service showed full buses once they arrived at the park. Moffet asked about the VRA reimbursement and it was noted the impact was just the reconciliation and transfers across funds. Moffet moved to approve Ordinance No. 17, Series of 2015 on first reading, the third and final 2015 budget supplemental; Bruno seconded the motion. There were no public comments made. The motion passed (7-0). The ninth item of business on the agenda was the review of the Evergreen Lodge at Vail Master Plan Amendment as presented by George Ruther, Director of Community Development. Chapin noted this item would be conducted as a Public Hearing with the Vail Town Council in order to present the Town of Vail Planning and Environmental Commission's recommendation of approval of the proposed amendment to the Lionshead Redevelopment Master Plan to the Detailed Plan Recommendations for the Evergreen Lodge at Vail. Council member Cleveland disclosed his role of serving on the Vail Valley Medical Center Board. Town Attorney Mire noted there was not a conflict of interest with this disclosure per the town charter and it was not necessary for Cleveland to recuse himself from the discussion. He also informed the council there would be an outline of steps to the evening's public hearing process and that the council would be asked to continue the topic to the next meeting. Ruther presented some background and noted the applicant, Evergreen Lodge at Vail, is proposing amendments to the detailed plan recommendation prescribed for the Evergreen Lodge at Vail in the Lionshead Redevelopment Master Plan, specifically Chapter 5 of the plan. Such amendments were reviewed in accordance with the provisions prescribed in Section 2.8 of the plan. He reminded council and the audience that this was not a review of the development application as this process would occur after the master plan was amended. He noted PEC served in an advisory role in making recommendations about the application. He presented the four purposes of the amendments as follows: Town Council Meeting Minutes of December 1, 2015 Page 3 1/5/2016 1. Clearly identify and articulate the desired outcomes of a future redevelopment of the Evergreen Lodge at Vail, 2. Remove language from the Master Plan which is no longer relevant or applicable, 3. Respond to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establish predictability within the review process by providing detailed site specific recommendations for redevelopment if the Evergreen Lodge at Vail site. Dominic Mauriello, Mauriello and Associates, representing the applicant, presented the application which outlined the proposed Evergreen modifications to the master plan. There were slides showing some of the application highlights, such as the current sites, photos of 1) the property, 2) middle creek, and 3) pedestrian path, the parcel ownership (VVMC, Evergreen owners, Town), review of the land trade that would occur with VVMC, a preview of the development concept with information about the current number of rooms and proposed number of rooms, what happens with landscaping, parking and circulation, building configurations, and South Frontage Road improvements with the construction of a roundabout. He then reviewed the Master Plan Sections and specific suggested changes in the plan pertaining to the topics listed above. Council comments were given about topics as follows: ✓ Support to review environmental studies completed that addressed the project's impacts on the stream tract, noting this project would create increased shading of the stream. ✓ Review of future uses and opportunities with public access in that particular neighborhood and Dobson Ice Arena. ✓ Discussion about creating appropriate access between VVMC and this property that would enhance the connection. ✓ Continued review of the location of the helipad and neighborhood impacts. Mauriello noted they continue to review the project relative to some of these topics. Mayor Chapin opened the hearing for public input at this time; he noted that comments were to be directed to the Vail Town Council only. Tom Braun, representing VVMC, informed council the land exchange was moving forward and noted some specific sections where he has some suggestions for language changes, page 6. Mery Lapin, 232 W. Meadow Drive, suggested several changes, as follows: 1) change stream setback to be 30 ft. from the high water mark resulting in increased stream protections, 2) include multiple condo associations as stand alone, 3) Vail should continue to own Lot 10, 4) review again the traffic on Meadow Drive and helipad location. Jim Lamont, Vail Homeowners Association, encourage them to preserve municipal site redevelopment opportunities, increase parking with another deck at Lionshead Structure, explore future civic facility in the neighborhood. Ruther submitted some final comments as follows: 1) he requested a continuation on the public hearing until the next meeting, 2) he reminded them the amendments were recommended by PEC, 3) he noted staff would continue to work with the all interested parties, VVMC and neighborhood residents, 4) staff would return at the next meeting with a resolution for consideration that would outline with the proposed plan amendments. There was interest from Town Council Meeting Minutes of December 1, 2015 Page 4 1/5/2016 several council members for further review of the town's ordinances related to the environmental protection of the stream and related setbacks as well as a review of current residential density requirements. Chapin noted the great collaboration and cooperation taking place between the stakeholders on this project. Moffet moved to continue the public hearing and discussion on the Evergreen Lodge at Vail Master Plan Amendment to the December 15, 2015 regular council meeting; Cleveland seconded the motion and it passed (7-0). The tenth item on the agenda was adjournment. There being no further business to come before the council, Foley moved to adjourn the meeting and Moffet seconded the motion which passed (7-0) and the meeting adjourned at 9:30 p.m. Respectfully Submitted, Attest: Dave Chapin, Mayor Patty McKenny, Town Clerk Town Council Meeting Minutes of December 1, 2015 Page 5 1/5/2016 Vail Town Council Meeting Minutes Tuesday, December 15, 2015 6:00 P.M. Vail Town Council Chambers The regular meeting of the Vail Town Council was called to order at approximately 6:00 P.M. by Mayor Dave Chapin. Members present: Dave Chapin, Mayor Jenn Bruno, Mayor Pro Tem Dick Cleveland Kevin Foley Kim Langmaid Jen Mason Greg Moffet Staff members present: Stan Zemler, Town Manager Matt Mire, Town Attorney Patty McKenny, Town Clerk The first item of business was Citizen Participation. Two representatives from the Vail Commons' housing complex addressed the Town Council with a request to consider allowing the Association to defer its land lease payments to the town in order to use the monies to fund a reserve account which would pay for future capital projects. The Town manager noted staff is currently reviewing the terms of the lease and the request and would return with more information at one of the January meetings. Karl Fauland, resident of Geneva Drive, thanked town staff for efforts to clean up their neighborhood. The second item on the agenda was the Town Manager's Report; there were no updates presented. The third item of business was the appointment of new members to the Commission on Special Events; it was noted seven applicants were interviewed during the work session. Bruno moved to appoint Kim Newbury Rediker, Mark Christie, and Sheena Richardson to the CSE for two year terms. Moffet seconded the motion and it passed (7-0). The fourth item of business was the appointment of one new member to PEC to serve the term vacated by newly elected council member Dick Cleveland. Two interviews were conducted during the work session. Bruno moved to appoint Ludwig Kurz to PEC to serve the term ending March 31, 2016. Cleveland seconded the motion and it passed (7-0). The fifth item on the agenda was a presentation by Ian Warda, Director of Burton Events, with an update about the Burton US Open Snowboard Championships to be held February 29 through March 5. There were also some introductions of new team members responsible for the production and operation of the upcoming event. There were some questions from town council members about the following items, 1) Burton programming related to environmental sustainability, 2) status of sponsorships and partners, 3) what kinds of event improvements Town Council Meeting Minutes of December 15, 2015 Page 1 1/5/2016 would be sought, 4) eligibility and qualification requirements, 5) the impacts from the town and need for Vail Resorts, Inc. in constructing and providing the infrastructure, 6) and the town's request for a complete and detailed after event report. It was noted the town fully supports the event with its production support and funding levels. The sixth item on the agenda was second reading of Ordinance No. 17, Series 2015 an Ordinance making budget adjustments to the Town of Vail General Fund, Capital Projects Fund, Real Estate Transfer Tax Fund, and Timber Ridge Enterprise Fund as presented by Carlie Smith, Budget Analyst. Zemler asked for input about the possibility of including a photovoltaic system with the remodel of the Golf and Nordic Clubhouse project as funding would need to be included in the first 2016 supplemental budget ordinance. There was unanimous support for researching this kind of installation and associated costs. Moffet moved to approve Ordinance No. 17; Foley seconded the motion. There was not public input on the ordinance. The motion passed (7-0). The seventh item on the agenda was Resolution No. 38, Series of 2015, a Resolution amending the Lionshead Redevelopment Master Plan to amend detailed plan recommendations for future development on the Evergreen at Vail development site, as prescribed in Chapter 5 of the Lionshead Redevelopment Master Plan, and setting forth details in regard thereto, as presented by George Ruther, Director of Community Development. Mayor Chapin noted the public hearing was continued from the last meeting and he opened the hearing at this time. Ruther addressed the resolution which depicts the amendments specifically addressed in Chapter 5, (including changes in 5.19.1 through 5.19.9) and he also spoke about Chapter 4 as it pertains to all of Lionshead relevant to such topics as the lodging hub, the connection to Vail Village, north -south orientation of buildings, loading and delivery, etc. He reviewed each of the objectives as addressed with amendments and noted the numerous community benefits that would result with revising the Master Plan. He spoke about the history of the master plan, the number of times it has been updated over the years, and how the Evergreen Lodge was added in 2005 and rezoned. There was a preview of the upcoming process as it related to the amendment review, the rezoning/subdivision and the development review which would be completed by both PEC and DRB. And finally, he recognized public input received from 1) Vail International Condominiums, a letter requesting further communication with the town to address their concerns and issues with the proposed amendments, and 3) Gwen Scalpello, a letter requesting the removal of language that references allowing a portion of Lot 10 to be used as potential mitigation for roundabout impacts to the Evergreen property. Dominic Mauriello, representing the applicant, also presented some slides addressing their perspective on the proposed amendments; he noted there were unanimous approvals of the amendments by PEC. He provided details about the property as it stands today and what would be proposed for the future, with a review of hotel rooms, condo units, food and beverage, meeting rooms, parking, etc. His listing of overall community benefits included the following: ✓ Release of covenants held by Evergreen on VVMC property ✓ Allows well over 100K sq. ft. of future expansion to VVMC main campus ✓ Addresses issues and impacts related to helipad and flight path over Evergreen Lodge ✓ Provides for north -south building orientation (goal of master plan) ✓ Allows for land trade ✓ Allows north -south pedestrian corridor through the property ✓ Reflects TOV proposed roundabout which impacts Evergreen property ✓ Requires protection and enhancement of Middle Creek corridor Town Council Meeting Minutes of December 15, 2015 Page 2 1/5/2016 ✓ Accommodates new TOV roundabout ✓ Prohibits vehicular access from W. Meadow Drive He also addressed and reviewed the "live beds" policy, the specific comments heard from the last public meeting, and provided a more thorough review of the impacts to Middle Creek by the proposed development, specifically comments about the 1) need for more set backs from the creek and 2) too much shading of Middle Creek. The applicant's perspective on these items was shared, and in summary, it was noted that an increase in creek setback was not "reasonable" because if affected the current development rights significantly; there were suggestions about other ways to address stream health. And, Mauriello noted the results of a "sun shade analyses" which showed the creek would be shaded during the day regardless of the buildings at a height of 4 or 8 stories in height. The comments from both Vail resident Scalpello and Vail International were addressed as he noted the language about Lot 10 was not binding in any way and they were willing to take into consideration the VI concerns about inside loading & delivery but would wait to proceed through the development review process before addressing the other concerns identified, i.e. stepping back and articulation of the building structure from the west. In closing, he requested a "vote yes" on the amendments in light of WMC and community benefits overall. Chapin opened the public hearing and input was received as follows: Tom Braun and Jim Wear, representing WMC, requested the council vote "yes" on the resolution as their concerns have been addressed. Rick Pylman, representing Vail International, expressed concern about the absence of an adjacent property notification and the concerns the association has with the proposed development, related to 1) loading and delivery, and 2) the building orientation. He requested more time allowing them a chance to review and resolve the issues. Heidi Hansen, Vail International resident, expressed their need for more time to work with attorneys and stakeholders about several issues. Mery Lapin, 232 W. Meadow Drive, expressed concerns as well, noting the following; 1) need to change the notification requirements to include broader range of neighborhoods when master plan amendments are being considered, 2) preferences for Middle Creek set backs, 3) concern with language related to trading or selling town owned Lot 10, . He requested the council delay the vote for two months allowing for more time for negotiations to occur which may resolve some of these concerns and issues, as there is a need to thoroughly understand the impacts and implications of the plan amendments. Jim Lamont, Vail Homeowners Association, suggested the notification requirements be changed to include all adjacent neighbors. Mayor Chapin thanked the public for the comments and closed this part of the hearing. There were brief closing remarks made by the applicant, Mauriello, who spoke about the upcoming development process and their willingness to continue to work with stakeholders, as well as the Director of Community Development, who clarified a few of the plan section changes made from the last meeting as a result of public input. There were some comments made by town council members related to Lot 10, the impacts to Middle Creek and need to continue a review of the area's riparian corridor, and suggestions made to the size of meeting/conference rooms. Town Council Meeting Minutes of December 15, 2015 Page 3 1/5/2016 Foley moved to table Resolution No. 38 and continue the public hearing until January 5, 2016. Langmaid seconded the motion and it passed (4-3; Chapin, Foley, Langmaid, Mason — yes; Bruno, Cleveland, Moffet — no). The Town Attorney reminded the members that no discussion about this matter should be held outside the hearing. The eighth item on the agenda was Resolution No. 37, Series of 2015, a Resolution allowing for an administrative extension to the approval for the Cornerstone Residences Approved Development Plan which is set to expire June 1, 2016, and setting forth details in regard thereto, as presented by George Ruther, Director of Community Development. It was noted on that on February 16, 2010, the Vail Town Council adopted Resolution No. 6, Series of 2010, which allowed for the administrative approval of an eighteen (18) month extension of the approved development plan for four projects. On March 6, 2012, the Vail Town Council adopted Resolution No. 13, Series of 2012, which allowed for an administrative approval of the approved development plans for four projects to June 1, 2015. On February 17, 2015, the Vail Town Council adopted Resolution No. 5, Series of 2015, which allowed for a one-year administrative extension to the lapse of approval for the Cornerstone Residences Approved Development Plan. This approval is set to lapse on June 1, 2016. He noted the recession was the cause for the delay of the project and their recommendation for approval of one more year as an extension. They are still required to meet all of their obligations including the employee housing requirement. Moffet moved to approve Resolution No. 37, Bruno seconded the motion. Cleveland noted he would vote against the extension because the development plan is almost 10 years old and it would be time for another review by DRB and PEC in light of new ownership and current regulations. Foley also noted he would vote no and also believes the older projects must come through the process for another round of review. Dominic Mauriello did point out that the parties purchasing the property just need more time to understand the development plan and requirements. The motion passed (4-3; Bruno, Langmaid, Mason, Moffet —yes; Cleveland, Foley, Chapin — no). The ninth item on the agenda was the Appeal of the Design Review Board's decision on Simba Run Condominiums' application for an exterior alteration (DRB150454), an appeal, pursuant to Section 12-3-3, Appeals, Vail Town Code, of the final decision of the Town of Vail Design Review Board on October 21, 2015, approving a dehumidifier, associated condenser and screen wall at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision, and setting forth details in regard thereto. It was noted due to a scheduling conflict with the Simba Run Homeowner's Annual Meeting, resulting in the applicant, the applicant's representative and the appellant being unable to attend the Town Council meeting, staff recommended continuing the public hearing to consider the above referenced appeal to the council's regular meeting schedule on January 5, 2016. Moffet moved to continue the hearing until January 5, 2016; Bruno seconded the motion and it passed (7-0). The tenth item on the agenda was adjournment. There being no further business to come before the council, Foley moved to adjourn the meeting and Moffet seconded the motion which passed unanimously, (7-0) and the meeting adjourned 8:40 p.m. Town Council Meeting Minutes of December 15, 2015 Page 4 1/5/2016 Respectfully Submitted, Attest: Dave Chapin, Mayor Patty McKenny, Town Clerk Town Council Meeting Minutes of December 15, 2015 Page 5 1/5/2016 1/5/2016 RESOLUTION NO. 1 Series 2016 A RESOLUTION APPROVING THE AMENDMENT TO THE DEVELOPMENT AGREEMENT BETWEEN THE TOWN OF VAIL AND LION'S RIDGE APARTMENT HOMES, LLC; AND SETTING FORTH DETAILS IN REGARD THERETO. WHEREAS, the Town of Vail (the "Town"), in the County of Eagle and State of Colorado is a home rule municipal corporation duly organized and existing under the laws of the State of Colorado and the Town Charter (the "Charter"); and WHEREAS, the members of the Town Council of the Town (the "Council") have been duly elected and qualified; WHEREAS, on August 19, 2014, the Council passed Resolution No. 18, Series 2014 approving the Development Agreement for the Timber Ridge Property; WHEREAS, the Development Agreement contains certain obligations with respect to the construction of Improvements on the Property; WHEREAS, the Town and Lion's Ridge Apartment Homes, LLC (the "Developer") desire to modify the deadline provided in the Development Agreement for the Developer's substantial completion of the Improvements. NOW, THEREFORE, BE IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO, THAT: 1. The Council hereby approves the Amendment to the Development Agreement and authorizes the Town Manager to enter into the Amendment to the Development Agreement on behalf of the Town in substantially the same form as attached hereto as Exhibit A and in a form approved by the Town Attorney. 2. This Resolution shall be effective immediately upon adoption. INTRODUCED, READ, APPROVED AND ADOPTED this 5t" day of January, 2016. Dave Chapin, Town Mayor ATTEST: Patty McKenny, Town Clerk Resolution No. 1, Series 2016 1/5/2016 EXHIBIT A AMENDMENT TO DEVELOPMENT AGREEMENT THIS AMENDMENT TO DEVELOPMENT AGREEMENT (this "Amendment") is made this day of January, 2016 (the "Effective Date"), by and between the Town of Vail, Colorado, a Colorado home rule municipality (the "Town") and Lion's Ridge Apartment Homes, LLC, a Colorado limited liability company (the "Developer"). WHEREAS, the Town and the Developer have entered into a Development Agreement dated September 10, 2014 and recorded on September 11, 2014 at Reception No. 201415584 in the public records of Eagle County, Colorado (the "Development Agreement"); WHEREAS, the Development Agreement contains certain obligations of Developer with respect to the construction of Improvements on the Property; WHEREAS, the Town and Developer now desire to modify the deadline provided in the Development Agreement for Developer's substantial completion of the Improvements, as further set forth below. NOW, THEREFORE, for and in consideration of the mutual promises and covenants contained herein, the sufficiency of which is mutually acknowledged, the Town and the Developer agree as follows: 1. Substantial Completion: The second sentence of Section 3(e) of the Development Agreement is hereby modified by deleting the phrase "the date that is 16 months after the date that Developer commences construction of the Improvements" and replacing it with the phrase "May 1, 2016." 2. Defined Terms. Except as otherwise defined herein, terms that are defined in the Development Agreement shall have the same meanings when such terms are used in this Amendment. 3. Confirmation of Terms; Conflict. Except as specifically modified and amended by this Amendment, all of the terms, covenants, and conditions of the Development Agreement shall remain in full force and effect. In the event of any conflict between the provisions of this Amendment and the Development Agreement, the provisions of this Amendment shall control. 4. Modification. This Amendment may only be modified by subsequent written agreement of the parties hereto. 5. Governing Law and Venue. This Amendment shall be governed by the laws of the State of Colorado, and any legal action concerning the provisions hereof shall be brought in Eagle County, Colorado. 6. Counterparts. This Amendment may be executed in one or more counterparts, which when taken together shall constitute one original of this Amendment. 7. Recording; BindingEffect. This Amendment shall be recorded with the Eagle County Clerk and Recorder. The benefits and obligations of the parties under this Amendment shall run with the land, and shall be binding on, and enforceable by, each of the parties hereto and their respective heirs, successors and assigns, and any subsequent holder of an interest in the Improvements or in the Property. WHEREFORE, the Town and the Developer have executed this Amendment as of the Effective Date. TOWN OF VAIL, COLORADO 1/5/2016 Stan Zemler, Town Manager ATTEST: Patty McKenny, Town Clerk DEVELOPER: LION'S RIDGE APARTMENT HOMES, LLC BY GORMAN EMPLOYEE GROUP LION'S RIDGE, LLC, Manager BY GORMAN & COMPANY, INC., Manager BY Gary J. Gorman, President STATE OF ) ss. COUNTY OF ) The foregoing instrument was subscribed, sworn to, and acknowledged before me this day of January, 2016, by Gary J. Gorman, the President of Gorman & Company, Inc., the Manager of Gorman Employee Group Lion's Ridge, LLC, the Manager of Lion's Ridge Apartment Homes, LLC. My commission expires: (SEAL) Notary Public 2 1/5/2016 EXHIBIT A LEGAL DESCRIPTION Lot 2, Timber Ridge Subdivision, A Resubdivision of Lion's Ridge Subdivision, Block C, A Resubdivision of Lots 1, 2, 3, 4 & 5, Town of Vail, County of Eagle, State of Colorado. 3 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Town Manager's Report: 1) Summit County Tour of Affordable Housing Properties and Special Council Meeting to discuss Chamonix Housing Project set for January 12, 2016 at 6 pm. PRESENTER(S): Stan Zemler, Town Manager 1/5/2016 Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: An appeal, pursuant to Section 12-3-3, Appeals, Vail Town Code, of the final decision of the Town of Vail Design Review Board on October 21, 2015, approving a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision, and setting forth details in regard thereto. (DRB150454) PRESENTER(S): Jonathan Spence, Planner ACTION REQUESTED OF COUNCIL: The question to be answered by the Vail Town Council regarding this appeal is: Were the requirements of the Vail Town Code, specifically Title 14, Chapter 10, Design Review Standards and Guidelines properly applied in the decision to allow for an exterior alteration for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West? Pursuant to Section 12-3-3, Appeals, Vail Town Code, the Vail Town Council shall uphold, uphold with modifications, or overturn the Design Review Board's October 21, 2015, decision. BACKGROUND: On September 16, 2015, the Design Review Board (DRB) reviewed a conceptual plan (DRB150388) for the installation of a dehumidifier, associated condenser and screen wall at the Simba Run Condominiums. A component of this conceptual review was a site visit to the subject property. On October 10, 2015, the Community Development Department, upon the direction from the DRB, approved an Exterior Alteration application (DRB150454), with no conditions, for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums. This decision became final on October 21, 2015 when the DRB affirmed this approval during the scheduled public hearing. On October 22, 2015, the Town of Vail Community Development Department received an appeal from Mr. Robert W. Kleinman, Owner, Simba Run Condominium Unit 2310 with regard to the Design Review Board's action to approve the aforementioned exterior alteration. STAFF RECOMMENDATION: Should the Vail Town Council choose to uphold the determination of the Town of Vail Design Review Board, the following statement is recommended: "The Vail Town Council finds as follows: The Vail Town Code was properly applied in regard to the October 21, 2015 Design Review Board approval of DRB150454. Furthermore, the project consisting of a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision, is consistent with Title 14, Development Standards, of the Vail Town Code." ATTACHMENTS: Staff Memorandum Memorandum Attachements Memorandum Attachments (2) 1/5/2016 0) VAIL 1 Memorandum TO: Vail Town Council FROM: Community Development Department DATE: January 5, 2016 SUBJECT: An appeal, pursuant to Section 12-3-3, Appeals, Vail Town Code, of the final decision of the Town of Vail Design Review Board on October 21, 2015, approving a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision, and setting forth details in regard thereto. (DRB150454) Appellant: Mr. Robert W. Kleinman, Owner, Simba Run Condominium Unit 2310 Planner: Jonathan Spence SUBJECT PROPERTY The subject property is located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision II. VAIL TOWN COUNCIL JURISDICTION Pursuant to Section 12-3-3C-1, Appeal of Design Review Board Decisions; Authority, Vail Town Code, the town council shall have the authority to hear and decide appeals from any decision, determination or interpretation by the design review board with respect to the provisions of Title 12, Zoning Regulations and Title 14, Development Standards, Vail Town Code. III. PROCEDURAL CRITERIA FOR APPEALS Pursuant to Sections 12-3-3C-2 and 12-3-3C-3, Appeal of Design Review Board Decisions; Initiation and Procedures, Vail Town Code, there are three basic procedural criteria for an appeal: A) Standing of the Appellants Pursuant to Section 12-3-3, Appeals, Vail Town Code, the appellant, Mr. Robert W. Kleinman, has standing as an aggrieved or adversely affected party to appeal the Design Review Board's October 21, 2015, decision. (DRB150454) 1/5/2016 IV. V B) Adequacy of the Notice of the Appeal A copy of the Public Notice of the Vail Town Council, December 16, 2014, Public Hearing was sent to the local newspaper on November 30, 2015 and published on December 1, 2015, pursuant to Section 12-3-3C-3, Procedures, Vail Town Code. This item was continued at the December 16, 2015, public hearing to the January 5, 2016 public hearing. C) Timeliness of the Notice of Appeal The Administrative Section of the Town's Zoning Code (12-3-3C-3, Procedures) requires appeals to be filed in twenty (20) days or less. On October 22, 2015, the appellant, Mr. Robert W. Kleinman, filed an appeal of the Design Review Board's October 21, 2015 decision in accordance with Section 12-3-3, Appeals, Vail Town Code. SUMMARY The question to be answered by the Vail Town Council regarding this appeal is: Were the requirements of the Vail Town Code, specifically Title 14, Chapter 10, Design Review Standards and Guidelines properly applied in the decision to allow for an exterior alteration for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West? Pursuant to Section 12-3-3, Appeals, Vail Town Code, the Vail Town Council shall uphold, uphold with modifications, or overturn the Design Review Board's October 21, 2015, decision. BACKGROUND On September 16, 2015, the Design Review Board (DRB) reviewed a conceptual plan (DRB150388) for the installation of a dehumidifier, associated condenser and screen wall at the Simba Run Condominiums. A component of this conceptual review was a site visit to the subject property. On October 10, 2015, the Community Development Department, upon the direction from the DRB, approved an Exterior Alteration application (DRB 150454), with no conditions, for a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums. This decision became final on October 21, 2015 when the DRB affirmed this approval during the scheduled public hearing. On October 22, 2015, the Town of Vail Community Development Department received an appeal from Mr. Robert W. Kleinman, Owner, Simba Run Condominium Unit 2310 with regard to the Design Review Board's action to approve the aforementioned exterior alteration. Town of Vail Page 2 1/5/2016 The following specific items of concern were mentioned in the appeal. 1. An assertion that the approval is inconsistent with Section 14-10-2 General Compatibility and 14-10-3 Site Planning related to the siting of the improvements. 2. A concern that the approval is inconsistent with Section 14-10-10 Accessory Structures; Utilities; Service Areas related to building materials. 3. A concern that the approval is inconsistent with Section 14-10-10 Accessory Structures; Utilities; Service Areas related to the requirement that all utility service systems be installed underground. 4. A concern that the operation of the equipment will subject the appellants and others to Legionnaires' Disease. VI. APPLICABLE DOCUMENTS The applicable planning documents are Vail Town Code, Title 14, Chapter 10, Design Review Standards of the Vail Town Code, as linked below. http://www.sterlingcodifiers.com/codebook/index.php?book id=560&chapter id=34648 VII. DISCUSSION ITEMS An assertion that the approval is inconsistent with Section 14-10-2 General Compatibility and 14-10-3 Site Planning related to the siting of the improvements. The Appellant contends that the siting of the improvements is inconsistent with the following code sections: 14-10-2: GENERAL COMPATIBILITY. A. Structures shall be compatible with existing structures, their surroundings, and with Vail's environment. It is not to be inferred that buildings must look alike to be compatible. Compatibility can be achieved through the proper consideration of scale, proportions, site planning, landscaping, materials and colors, and compliance with the guidelines herein contained. B. Any building site in Vail is likely to have its own unique landforms and features. Whenever possible, these existing features should be preserved and reinforced by new construction. The objective is to fit the buildings to their sites in a way that leaves the natural landforms and features intact, treating the buildings as an integral part of the site, rather than as isolated objects at odds with their surroundings. (Ord., 9-21-1999) Town of Vail Page 3 1/5/2016 14-10-3: SITE PLANNING: A. The location and configuration of structures and accessways shall be responsive to the existing topography of the site upon which they are to be located. Grading requirements resulting from development shall be designed to blend into the existing or natural landscape. Any cuts or fills shall be sculptural in form and contoured to blend with the existing natural undisturbed terrain within the property boundary. B. Building siting and access thereto shall be responsive to existing features of terrain rock outcroppings, drainage patterns, and vegetation. C. Removal of trees, shrubs, and other native vegetation shall be limited to removal of those essential for development of the site, those identified as diseased, those essential for creating defensible space, and those found to impact view corridors as further regulated by title 12, chapter 22, "View Corridors", of this code. Mitigation may be required for tree removal. D. All areas disturbed during construction shall be revegetated. If necessary, the design review board may designate allowable limits of construction activity and require physical barriers in order to preserve significant natural features and vegetation upon a site and adjacent sites during construction. (Ord. 10(2012) § 3: Ord. 3(2007) § 3: Ord., 9-21-1999) The appellant contends that the regrading, tree removal and material export that are necessary for the installation of the equipment is inconsistent with the above code sections. After a site visit and discussion on the project, the DRB concluded that the proposed structure was compatible with its location through similar scale and like materials to the existing pool building. Although the project will require the removal of (4) mature Aspen trees and (1) mature Hawthorn, the DRB found that the landscape plan that includes the preservation of (3) Blue Spruce augmented with (3; new 8'-12' foot Blue Spruce, (5) new 2'/2"-3" caliper Aspens, (4) new 5 gal. Alpine Currant and (5) new 5 gal. Potentillas was sufficient to meet the criteria established in Sections 14-10-2 and 14-10-3. Town of Vail Page 4 1/5/2016 2. A concern that the approval is inconsistent with Section 14-10-10 Accessory Structures; Utilities; Service Areas related to building materials. The Appellant contends that the building materials of the proposed improvements are inconsistent with the following code section: 14-10-10: ACCESSORY STRUCTURES; UTILITIES; SERVICE AREAS: A. Design of accessory structures upon a site shall be compatible with the design and materials of the main structure or structures upon the site. The appellant contends that the project includes the use of a Kalwall or similar roof system. The concern is the possibility of reflecting direct sunlight (sic) onto adjacent dwelling units and the general incompatibility of the roof system with existing building materials. The project does not include a roof of any sort over the new enclosure. 3. A concern that the approval is inconsistent with Section 14-10-10 Accessory Structures; Utilities; Service Areas related to the requirement that all utility service systems be installed underground. The Appellant contends that proposed above ground improvements are inconsistent with the following code section. 14-10-10: ACCESSORY STRUCTURES; UTILITIES; SERVICE AREAS C. All utility service systems shall be installed underground. Any utility system the operation of which requires aboveground installation shall be located and/or screened so as not to detract from the overall site design quality. The DRB recognized that unlike dry utilities and those that are piped, the proposed mechanicals, consisting of a dehumidifier and condenser, are not appropriate underground. The DRB found that the proposed screen walls and landscaping effectively screened the utility and that the proposal will not detract form the overall site design quality, consistent with Section 14-10-10. 4. A concern that the operation of the equipment will subject the appellants and others to Legionnaires' Disease. Although the Vail Town Code has as its general purpose the promotion of the health, safety, morals and general welfare of the town, staff, acting on behalf of the DRB at the time of the decision, was unaware of this potential concern. Since the filing of the appeal, staff has been unable to validate through discussions with the applicant and a general internet search the appellant's assertion that the equipment will promote the establishment, propagation or dispersal of the bacterium that causes Legionnaires ' Disease. Town of Vail Page 5 1/5/2016 VIII. REQUIRED ACTION Pursuant to Section 12-3-3, Appeals, Vail Town Code, the Vail Town Council shall uphold, uphold with modifications, or overturn the Design Review Board's October 21, 2015, decision. Should the Vail Town Council choose to uphold the determination of the Town of Vail Design Review Board, the following statement is recommended: "The Vail Town Council finds as follows: The Vail Town Code was properly applied in regard to the October 21, 2015 Design Review Board approval of DRB150454. Furthermore, the project consisting of a dehumidifier, associated condenser, screen wall and landscaping at the Simba Run Condominiums, located at 1100 North Frontage Road West/Lots 6-10, Block C, Lion's Ridge Subdivision, is consistent with Title 14, Development Standards, of the Vail Town Code IX. ATTACHMENTS A. Approved plans dated September 24, 2015 B. Appellant's submittal including narrative and attachments. Town of Vail 1/5/2016 STANDARD ABBREVIATIONS ABV ABOVE ELEV ELEVATOR LIN LINEN RS ROUGHSAWN ACOUS ACCOUSTICAL EM EMERGENCY OUTLET LKR LOCKER RWC RAIN WATER CONDUCTOR ACT ACCOUSTICAL CEILING TILE EMER EMERGENCY LLH LONG LEG HORIZONTAL ALTERNATE SITE PIERCE ADD ADDENDUM ENG ENGINEER LLV LONG LEG VERTICAL S SOUTH ADJ ADJUSTABLE E EDGE OF SLAB LT LIGHT SC SOLID CORE AFF ABOVE FINISHED FLOOR EQEQUAL PIERCE LTL LINTEL SCD SEAT COVER DISPENSER AFG ABOVE FINISHED GRADE EQUIP EQUIPMENT LTWT LIGHTWEIGHT SCHED SCHEDULE AG AGGREGATE EXIST EXISTING LVR LOUVER SD SOAP DISPENSER AL ALUMINUM EXP EXPANSION SECT SECTION ALT ALTERNATE EXT EXTERIOR M MASTER SF SQUARE FEET ANCH ANCHOR MACH MACHINE SG LT STRUCTURAL GLU-LAM TIMBER APPROX APPROXIMATELY FAS FASTEN(ER) MAS MASONRY SHLVS SHELVES APSH ASPHALT FB O FURNITURE BY OWNER MAT MATERIAL SHR SHOWER ARCH ARCHITECTURAL FD FLOOR DRAIN MAX MAXIMUM SHT SHEET ASI ARCHITECT'S SUPPLEMENTAL FDN FOUNDATION MECH MECHANICAL SILT G SHEATHING INSTRUCTIONS FE FIRE EXTINGUISHER MEP MECHANICAL, ELECTRICAL and SIM SIMILAR ATTEN ATTENUATION FEC FIRE EXTINGUISHER CABINET PLUMBING SPEC SPECIFICATION(S) AUTO AUTOMATIC FFE FINISH FLOOR ELEVATION MFGR MANUFACTURER SQ SQUARE FFL FINISHED FLOOR LINE MH MAN HOLE SR SINK RECEPTACLE BD BOARD FHC FIRE HOSE CABINET MIN MINIMUM SS STAINLESS STEEL BDRM BEDROOM FIN FINISH(ED) MIR MIRROR SSK SERVICE SINK BEL BELOW FIX FIXTURE MISC MISCELLANEOUS SST STAINLESS STEEL BET BETWEEN FLG FLASHING MMB MEMBRANE ST STAIN BKT BRACKET FLR FLOORING) MO MASONRY OPENING STA STATION BLDG BUILDING FLUOR FLUORESCENT MTD MOUNTED STD STANDARD BLK BLOCK FPHB FREEZE PROOF HOSE BIB MTL METAL S STEEL BUR BOILER FR FIRE RESISTIVE MUL MULLION STO STORAGE BM BEAM FREZ FREEZER MW MICROWAVE STRUCT STRUCTURE or STRUCTURAL BO BYOWNER FIRM FRAME SUSP SUSPEND(ED) BOF BY OWNER, FUTURE FRP FIBERGLASS REINFORCED (N) NEW SV SHEET VINYL BOT BOTTOM PANEL(ING) N NORTH SVM SYMMETRICAL BOW BOTTOM OF WALL FRT FIRE RETARDANT TREATED NIC NOT IN CONTRACT SVS SYSTEM ERG BEARNING FT FEET No NUM BSMT BASEMENT FTG FOOTING NOM NOMINAL T TREADS FURR FURRING NTS NOT TO SCALE T&B TOP AND BOTTOM CAB CABINET FULL FUTURE T&G TONGUE AND GROOVE CAN CABLE TELEVISION FV FIELD VERIFY OA OVERALL TB TOWEL BAR CB CATCH BASIN OC ON CENTER TEL TELEPHONE CCD CONSTRUCTION CHANGE GA GAUGE OD OUTSIDE DIAMETER THK THICK or THICKNESS DIRECTIVE GALV GLAVANIZED OFF OFFICE THR THRESHOLD CCN CLOSED CIRCUIT TELEVISION GB GRAB BAR OH OPPOSITE HAND THRU THROUGH CEM CEMENT GCMU GLAZED CONCRETE MASONRY OPG OPENING TO TOP OF CER CERAMIC UNIT(S) Opp OPPOSITE TOC TOP OF CONCRETE CFL COUNTERFLASHING GD GRADE OTO OUTSIDE -TO -OUTSIDE TOV TOWN OF VAIL CG CORNER GUARD GEN GENERAL TOW TOP OF WALL CIP CAST IN PLACE GFP GAS FIREPLACE PAC PR EVIOUSLYAWARDED TPH TOILET PAPER HOLDER CJ CONTROL JOINT GI GALVINIZED IRON CONTRACT TPTN TOILET PARTITION CK CAULK(ING) GL GLASS PARTN PARTITION N TELEVISION CL CENTERLINE GND GROUND PFB PREFABRICATED TYP TYPICAL CLG CEILING GRT GROUT PH PHONE CLL CONTRACT LIMIT LINE GYP GYPSUM WALL BOARD PL PLATE UL UNDERWRITER'S LABORATORY CLOS CLOSET PLAM PLASTIC LAMINATE UNF UNFINISHED CLR CLEARANCE HB HOSE BIB PLAS PLASTER UON UNLESS OTHERWISE NOTED CMU CONCRETE MASONRY UNIT HC HOLLOW CORE PUNK PLANK UOS UNLESS OTHERWISE SPECIFIED CNTR COUNTER HD HEAD PLWD PLYWOOD UR URINAL CO CLEAN OUT HDCP HANDICAP(PED) PNL PANEL CoL COLUMN HDRL HAND RAIL PNT PAINT V VACUUM CON CONCRETE HDW HARDWARE PNTD PAINTED VB VAPOR BARRIER CONN CONNECTION HDWD HARDWOOD PORC PORCELAIN VCP VITRIFIED CLAY PIPE CONST CONSTRUCTION HM HOLLOW METAL PR PROPOSAL REQUEST VCT VINYL COMPOSITION TILE CONT CONTINUOUS HORIZ HORIZONTAL PR PAIR VERT VERTICAL CONTR CONTRACT(OR) HR HOUR PROJ PROJECT VEST VESTIBULE CORR CORRIDOR HT HEIGHT PSF POUNDS PER SQUARE FOOT VIN VINYL CPT CARPET HTR HEATER PSI POUNDS PER SQUARE INCH VTR VENT TO ROOF CT CERAMIC TILE HVAC HEATING, VENTILATION and AIR PTD PAPER TOWEL VWC VINYL WALL COVERING CTR CENTER CONDITIONING DISPENSER RECEPTACLE CTSK COUNTERSINK PV PAVEMENT W WASHER D DRYER IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR QT QUARRYTILE W/ WITH DBL DOUBLE ID INSIDE DIAMETER WHO WITHOUT IN INCH R RISERS WATER -RES WATER RESISTANT DEPT DET DEPARTMENT DETAIL INFO INFORMATION RAD RADIUS WB WASTEBASKET OF DRINKING FOUNTAIN INSUL INSULATION or INSULATED RD ROOF DRAIN WC WATER CLOSET DIA DIAMETER INT INTERIOR RE REFER TO or REFERENCE WD WOOD DIAG DIAGONAL INTX INTERSECTION RE RECESS(ED) WF WIDE FLANGE DIM DIMENSION INV INVERT REF REFRIGERATOR or REFRIGERATED WIN WINDOW DN DOWN REINF REINFORCED WP WATERPROOFING) DR DRAIN JAN JANITOR REQ'D REQUIRED WPT WORKING POINT DS DOWNSPOUT JB JUNCTION BOX RES RESISTANT WWF WAINSCOT DW DISHWASHER JT JOINT RESIL RESILIENT WWF WELDED WIRE FABRIC DWG DRAWING RET RETAINING DWR DRAWER K.D. KNOCKDOWN REV REVISE, REVISED or REVISION K.O. KNOCKOUT RF RESILIENT FLOORING E EAST KIT KITCHEN RFG ROOFING EA EACH KPL KICK PLATE RFL REFLECTED EH EXHAUST FAN RL RAIN LEADER EJ EXPANSION JOINT LAB LABORATORY RM ROOM EL ELEVATION LAM LAMINATE RO ROUGH OPENING ELECT ELECTRICAL LAV LBL LAVATORY LABEL ROD ROOF OVERFLOW DRAIN MISC. ABBREVIATIONS 0 ROUND W/ WITH o DEGREES ± PLUS OR MINUS R PROPERTY LINE < ANGLE SIMBA RUN CENTER LINE DRAWING CONVENTIONS DETAIL DESIGNATOR SIM '1 DETAIL NUMBER A101 SHEET WHERE SHOWN BUILDING SECTION DESIGNATOR SIM I1 SECTION LETTER 10 1 SHEET WHERE SHOWN 1001-0r' LEVEL INDICATOR 1001-0" SPOT ELEVATION 1 DOOR DESIGNATOR 101 1i WINDOW DESIGNATOR O REFERENCE Room name 101 r REVISED AREA OF DRAWING ADDENDUM � 1/5/2016 1 i WALL TYPE VICINITY MAP 1 E.. PROJECT AREA = R 'YZLE NOT _: ,/�. ✓ y` ,_ NODE MV 1 Vw' ^` II FRbN�AGE R0� NOR" _SITE PLAN WMTH SHEET INDEX DISCIPLIN LL, SHEET # DESCRIPTION BY E ISSUE DATE A000 SIMBA RUN PIERCE ARCHITECTURAL 09/24/2015 ARCHITECTS ^L, W A001 ALTERNATE SITE PIERCE ARCHITECTURAL 09/24/2015 U z ARCHITECTS J A002 3D VIEWS PIERCE ARCHITECTURAL 09/24/2015 co ARCHITECTS a A003 ALTERNATE ELEVATIONS PIERCE ARCHITECTURAL 09/24/15 ARCHITECTS rte,. Vkw„ ADMINISTRATIVE INFO. LEGAL DESCRIPTION OF PROPERTY: Situs Address 000103 WILLOW PL #301 Tax Area SC 103 - VAIL (TOWN) - SC 103 Parcel Number 2101-082-15-009 Legal Summary DESC: PK SP 6 & 17 Subdivision: EDELWEISS CONDOMINIUMS Unit: 301 BK -0309 PG -0167 WD 04-14-79 R823566 DEC 02-13-03 R200626666 QCD 09-11-06 R200800057 DEC 01-02-08 BUILDING CODE SUMMARY BUILDING CODE: 2012 IBC CONSTRUCTION TYPE: TYPE III DWELLING UNITS: 1 TOTAL SQUARE FOOTAGE: 1062 SQ. FT. PROJECT DIRECTORY OWNER: STEPHEN & RITVA FERRISS 785 CRANDON BLVD, APT. 1605 KEY BISCAYNE, FL 33149-2536 ADr' IITCrT• M11 I DICDrC DDlnl('`IDAI Inl rWA D(_C' PIERCE ARCHITECTS 1650 E. VAIL VALLEY DRIVE, C1 VAIL, COLORADO 81657 P: 970.476.6342 F: 970.476.4901 E: BILL@VAILARCHITECTS.COM CONTRACTOR: MARK HALLENBECK ROCKY MOUNTAIN CONSTRUCTION GROUP P: 1-970-476-4458 M: 1-719-499-9248 E: markh@rockymountainconstructiongroup.com STRUCTURAL ENGINEER: N/A N/A N/A P:: N/A F: N/A E: N/A MECHANICAL ENGINEER: N/A N/A N/A P: N/A F: E: N/A INTERIOR DESIGN: N/A N/A N/A P: N/A F: N/A E: N/A LANDSCAPE ARCHITECT: N/A N/A N/A P: N/A F: N/A E:: N/A LIGHTING DESIGN: N/A N/A N/A P: N/A F: N/A E: N/A SIMBA RUN HUMIDITY MITIGATION CONSTRUCTION DOCUMENTS 14 OF a Q01 DRB APPROVED 10/9/2015 12:00:00 AM 09/24/2015 DRB z LL, a 04 0 J 1 /'1 (i d' l IM'� _ v ^L, W 00 M J U z LLJ J � o co > a Q 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-634, SIMBA RUN 3D VIEW 1 -ALTERNATE SITE CONDENSER STRUCTURE TO SUPPORT CONDENSER ABOVE DEHUMIDIFIER EXISTING WINDOWS GATES WITH LOUVERS CONDENSER REVEALS TO MATCH NEW CONCRETE WALL, TO MATCH EXISTING 3D VIEW 2 - ALTERNATE SITE 3D VIEW 3 - ALTERNATE SITE ( SCREEN WALLS TRANSPARENT) 1/5/2016 CONDENSER STEEL CONDENSER STRUCTURE TO SUPPORT CONDENSER ABOVE DEHUMIDIFIER EXISTING WINDOWS GATES WITH LOUVERS NEW WALL, SIDING TO MATCH EXISTING NEW CONCRETE WALL, PAINT TO MATCH EXISTING CONDENSER STEEL CONDENSER STRUCTURE TO SUPPORT CONDENSER ABOVE DEHUMIDIFIER EXISTING WINDOWS GATES WITH LOUVERS DEHUMIDIFIER @ ELEVATION 8116'-0" NOTE: SLAB TO BE EXTENDED 6" BEYOND EQUIPMENT. NEW CONCRE TO MATCH EX NOTE: SLAB T, EXTEND 6" BE EQUIPMENT. DEHUMIDIFIEF @ ELEVATION GATES WITH L STEEL CONDE STRUCTUREZ SUPPORT COf ABOVE DEHUP CONDENSER NOTE: EXISTII` GRADING TO REMAIN (4) NEW 5 GAI ALPINE CURR (5) NEW 5 GAI POTENTILLA 4 SITE PLAN - ALTERNATE SITE 1/8" = V-011 SITE PLAN - ALTERNATE LANDSCAPE 1/8" = 1'-0" ki Or %k%� q0_1 DRB APPROVED 10/9/2015 12:00:00 AM 09/24/2015 DRB z LL, Q o 0 J COCSO 00 a� Q >0m J U z _j m >J Q 'o M i a O r91 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 ALTERNATE SITE A001 P. 0 - 3D VIEW - EXISTING - 3RD FLOOR 1 DECK - 8130'-0" 3D VIEW -EXISTING - 6TH FLOOR DECK - 8160'-0" 1/5/2016 0 - 3D VIEW - ALT LOCATION - 3RD 2 FLOOR DECK - 8130'-0" 3D VIEW - ALT LOCATION - 6TH FLOOR DECK - 8160'-0" ki 0jr Q0_1 DRB APPROVED 10/9/2015 12:00:00 AM 09/24/2015 DRB z Ui Q o _J(.0 r ry ^ 0 Om �v z Q 'o cy) > a CD r91 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 3D VIEWS A002 P. EXISTING CONCRETE WALL NMI _ EL 8140 8140'-0" V NEW CONCRETE WALL (PAINT TO MATCH) T.O.W. 1 , 8132'-3" r _ ` �_�� .. - - •' -. - •�- , , . .. µ _ • ,. �. .- . - - - . , - . - - '� - � EL 8130 8130'-p.. REVEALS TO MATCH ------------- EXISTING RETAINING WALL TO REMAIN — I -- — — — EL 812 8120'-0" � I I f II � 11 � I I � I I 1 l _ I f I I � I � — � I .�.._ _ - _._ �.�_.� ::•.::.:`� � ::�., :==�-,�.�..-:_,:•.- �: ,•-..: � ; _.:•: � ::.: •.:.,,- __- I1—I—I1 POOL 8116'— O -1I III III III III III II III I I II II ELEVATION - WEST EXTERIOR 1/4" = 1'-0" 25'4' 23'-8" EXISTING WALLS _ EL 8140 8140'- 0" NEW CONCRETE WALL CONDENSER SUPPORTED BY ° --------------- STRUCTURE (TOP OF CONDENSER AT LEAST 2'-0" BELOW ADJACENT WALL) GATES WITH ' LOUVERS T.O.W. 1 8132 3 - a - — a EL 8130 -------------- - 8130'-0" STEEL STRUCTURE EXISTING — TO SUPPORT z WINDOWS CONDENSER W CD DEHUMIDIFIER Uj @ ELEVATION 8116'-0" z - - - - - - - - - - - - - - - - - - - - -- - - SLAB TO BE EXTEND 6" BEYOND EQUIPMENT._ I I �I ! ! I I I III, , I I, , I, , I—I ,4q — — — — — 8EL 120'1 00 I—III—III— I I °� 17— POOL p., FOUNDATION DRAIN — _ = —III—I�— I III III III I I d 1 III III I I I FOUNDATION DRAIN_—_ CONCRETE FOOTINGS — — — — — — — — — — — — — — — — CONCRETEI FOOTI-11 NGS= II III III 1I III III IIIIIII�IIIIII� IIII�II�IIII VIII IIII Il I R I — I l l-! I I SECTION 1 1/411 = 1'-0" 1/5/2016 16'-0" EXISTING CONCRETE WALL 3 A003 CONDENSER, ON PLATFORP SIDING TO Mf EXISTING GATES WITH LOUVERS ELEVATION - NORTH EXTERIOR 1/411 = 1'-0" ELEVATION - SOUTH EXTERIOR 1/411 = 1'-0" _ EL 8140 8140'- 0" T.O.W. 1 AL 8132'- 3" _ EL 8130 8130'-0" F EL 8120 8120' - 0" _ POOL 8116'-0" ki Or zN011 DR APPROVED 10/9/2015 12:00:00 AM 09/24/15 DRB z LL, Q ; o CO r �— 00 a� Q 00 E J U z J> J m Q 'o > a — o bL 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 ALTERNATE ELEVATIONS A003 Tl7WU OFA[L'i Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2138 Application for Design Review Exterior Alteration w vw.vaifgov.com General information: This application is required for all proposals involving minor changes to buildings and site improve- ments, such as roofing, painting, window additions, landscaping, fences, retaining walls, etc. Applicable Vail Town Code sections can be found at www.vailgov.com under Vail Information — Town Code Online, All projects requiring de- sign review must receive approval prior to submitting a building permit application. An application for Design Review cannot be accepted until all required information is received by the Community Development Department, as outlined in the submittal requirements. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval expires one year from the date of approval, unless a building per- mit is issued and construction commences. Fee: $250—Multi-Family/Commercial $20—Single Family/Duplex Single Family Duplex X Multi -Family Commercial Description of the Request: 9&*4 Physical Address: Parcel Number: % 2 - ;)'" 1����� � (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Property Owner: C Z -E–= 16,21 Mailing Address:►', Owner's Signature: Signature: Primary Contact/ Owner Representative:` . Mailing Address: ( Phone: E -Mail: L1___qS.!4_! lavl,_L�L12L, 4�,o V1,L. Fax: For Office Use Only: Cash_ CC: Visa/ MC Pee Paid: Meeting Date: Planner: zoning: !vocation of the Proposal: Last 4 CC # Exp Lot: Block: Date, Auth # Check # Received From: DRB No.: Project No: Land Use: Subdivision: Mav 2015 1/5/2016 TOWN OF VAIL' JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER The applicant must submit written joint property owner approval for applications affecting shared ownership properties such as duplex, condominium, and multi -tenant buildings. This farm, or similar written correspondence, must be com- pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con- dominium or multi -tenant building. All completed forms must be submitted with the applicants completed application. 1-1 1, (print name)�'? fir, or authority of the association, of property located at } i'" provide this letter as written approval of the plans dated 09/24/15 which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address not- ed above. I understand that the proposed improvements include: 7 7A=9- 64-244774 I understand that modifications may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to Keep the joint property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an application results in the applicant agreeing to this statement. E Signature Print Name &1,-,�v� Date 1/5/2016 PROPOSED LANDSCAPING Botanical Name Common Name Quantity Size PROPOSED TREES 45 5 AND SHRUBS 0 EXISTING TREES e TO BE REMOVED Minimum Requirements for Landscaping GROUND COVER SOD SEED IRRIGATION TYPE OF EROSION CONTROL Deciduous Trees — 2" Caliper Coniferous Trees — 6' in height Shrubs — 5 Gal. Tvpe Square Footage Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.) 1/5/2016 PROPOSED MATERIALS Building Materials Type of Material Color Roof Siding Other Wall Materials A-1 4=7-'F,— , Fascia Fascia , A Soffits 1� Windows Window Trim Doors ,4. a LJ f% -►"'.r,„/ �j%,��1` Door Trim/ Hand or Deck Rails !1 Flues Flashing I� Chimneys Trash Enclosures 11 Greenhouses Retaining Walls Exterior Lighting Other Notes: Please specify the manufacturer's name, the color name and number and attach a color chip. 1/5/2016 CO&%"ITY DEVELOPMENT Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www.vailgov.com Project Name: SIMBA RUN DEHUMIDIFER & CONDEN DRB Number: DRB150454 Project Description: COMMON ELEMENT:INSTALLATION OF DEHUMIDIFIER AND ASSOCIATED CONDENSOR AND SCREEN WALL Participants: OWNER HURFORD, HILGE M. & JENNIFER 09/28/2015 175 E 62ND ST NEW YORK, NY 10021 ARCHITECT PIERCE ARCHITECTS 09/28/2015 Phone: 970-476-6342 1650 FALLRIDGE ROAD SUITE C-1 VAIL CO 81657 License: C000003130 APPLICANT SIMBA RUN CONDOMINIUM ASSOCI 09/28/2015 Phone: 970-476-0344 C/O FARROW HITT ..v..-,....___l.].DQ_LLO1�lSRI1��.LQOP____.__..._.__�._..,e._..-..-�.,..�..._�....._........�....,�......,......._ _... VAII, CO, 81657 Project Address: 1100 LIONS RIDGE LP VAIL Location: SIMBA RUN: COMMON ELEMENT Legal Description: Lot: 6-10 Block: C Subdivision: SIMBA RUN Parcel Number: 2103-121-1300-1 Comments: Please see below. BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 10/09/2015 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of 1/5/2016 approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond:202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Jonathan Spence DRB Fee Paid: $250.00 1/5/2016 Robert W. Kleinman 1100 North Frontage Road Unit 2310 Vail, CO 81657 970 331 4654 boW,,maddyandbob. com October 22, 2015 Town of Vail Community Development Department 75 South Frontage Road Vail, CO 81657 Ladies and Gentlemen: We submit herewith our Appeal of actions taken by the Vail Design Review Board on October 21, 2015 and any prior or related actions and approvals, all in connection with the proposed Simba Run Condominium Swimming Pool Building Humidity Mitigation Project. If you require anything further from me in connection with this matter, please contact me via email at bob&maddyandbob.com. Thank you for your assistance. Very truly yours, X -P Robert W. Kleinman, Appellant and Homeowner OCT 23 2015 TOWN OF VAIL 1/5/2016 Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970-479-2128 www.vailgov.com Development Review Coordinator Appeals Form General Information: This form is required for filing an appeal of a Staff, Design Review Board or Planning and Environmental Commission action/decision. A complete form and associated requirements must be submitted to the Community Development Department within twenty (20) calendar days of the disputed action/decision. Action/Decision being appealed: THE APPROVAL OF THE PROJECT REFERENCED AS DRB 150388, SIMBA RUN CONDOMINIUM SWIMMING POOL BUILDING HUMIDITY MITIGATION PROJECT, CONSISTING OF: THE INSTALLATION OF LARGE ABOVE -GROUND COMMERCIAL "DESERT AIRE" DEHUMIDIFICATION SYSTEMS AND CONDENSERS; THE CONSTRUCTION OF SURROUNDING AND ADJACENT WALLS, SCREENS, ROOFING AND GATES; THE INSTALLATION OF HYDRONIC PIPING, REFRIGERANT PIPING, CONDENSATE PIPING AND NATURAL GAS PIPING; CONSTRUCTION OF ALL OTHER RELATED AND INCIDENTAL STRUCTURES AND COMPONENTS; AND THE PROPOSED REGRADING OF EXISTING LAND AND REMOVAL OF MATURE TREES. Date of Action/Decision: OCTOBER 21, 2015, AND ALL PRIOR ACTIONS OF THE TOWN OF VAIL DESIGN REVIEW BOARD OR ITS STAFF THAT ARE APPEALABLE AT THIS TIME AND UNDER THE CIRCUMSTANCES PRESENT IN THIS APPEAL. Board or Staff person rendering action/decision: TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT AND/OR DESIGN REVIEW BOARD AND STAFF, INCLUDING JONATHAN SPENCE AND ANY OTHER AS YET UNIDENTIFIED EMPLOYEES OF SUCH OR OTHER AGENCIES OR DEPARTMENTS OF THE TOWN OF VAIL. Does this appeal involve a specific parcel of land? YES If yes, are you an adjacent property owner? YES 1/5/2016 Names of Appellants: ROBERT W AND MADELAINE M KLEINMAN Mailing Address: ROBERT W KLEINMAN 61 L'ORANGE PLACE KAILUA, HI 96734 Phone: 970 331 4654 Contact email address (please use for all communications) — bob@maddyandbob.com Physical Address in Vail: UNIT 2310, SIMBA RUN CONDOMINIUMS 1100 NORTH FRONTAGE ROAD VAIL, CO 81657 Legal Description of Appellant (s) Property in Vail: Simba Run Unit 2310, BK- 0352 PG- 0154 DEC 01-18-83 BK- 0432 PG- 0941 WD 12-19-85 BK- 0545 PG- 0469 CER 12-19-90 R200817204 DEC 08-13-08 Tax Parcel No. 210312113077 Appellants Signatures: Dated: October 22, 2015 SEE THE ATTACHED SUBMITTALS AND EXHIBITS SUBMITTAL REQUIREMENTS 1. On a separate sheet or separate sheets of paper, provide a detailed explanation of how you are an "aggrieved or adversely affected person". 2. On a separate sheet or separate sheets of paper, specify the precise nature of the appeal. Please site specific code sections having relevance to the action being appealed. 3. Provide a list of names and addresses (both mailing and physical addresses in Vail) of all owners of property who are the subject of the appeal and all adjacent property owners 1/5/2016 (including owners whose properties are separated from the subject property by a right-of-way, stream or other intervening barrier). 4. Provide stamped, addressed envelopes for each property owner listed in (3). Submit this form and all submittal requirements to: Town of Vail Community Development Department 75 South Frontage Road Vail, CO 81657 For Office Use Only: Date Received: Activity No.: Planner: Project No: _ 1/5/2016 ATTACHMENT 1 TO APPEAL DATED OCTOBER 22, 2015 ROBERT AND MADELAINE KLEINMAN, APPELLANTS How Appellants are an "aggrieved or adversely affected person" — We own Simba Run condominium unit no. 2310, the home that is immediately adjacent to the proposed Project. We have previously submitted an Appeal dated October 17, 2014 (the "2014 Appeal") in protest of the prior iteration of the same project, and we refer to that Appeal for additional information in support of our current Appeal. We live in our Simba Run home as our principal residence, and live there approximately six months each year, during the summer and winter months. What is being proposed is the above -ground installation of commercial sized condensers and dehumidification systems, and structures to surround such equipment, resulting in the placement of this equipment and structures immediately outside of our home, within feet of our living space. The main structure will be approximately the size of a railroad freight car, will impact our views and will create a significant health hazard, and noise, fog and general nuisance. As described in the following attachments, this Project violates the spirit and letter of the Town of Vail Design Review Board ordinances and the laws of the State of Colorado, including, without limitation, the Design Review Standards and Guidelines of the Town of Vail and the Noise Abatement statutes of the State of Colorado, including C.R.S. 25-12-101 through 103, et seq. Of even greater concern, as more fully described herein, the Project will create an unacceptable risk of Legionnaires' Disease to Appellants and others that come in contact with this equipment, a risk that Applicant has failed to address and cannot mitigate. Appellants are available to provide any additional information required by the Department of Community Development to resolve this Appeal and wish to receive timely notice of and to participate in any further hearings or other actions taken in connection with the Project, the application or this Appeal. Without limiting the generality of the foregoing, Appellants wish to present their opposition to the Project at the next meeting of the Design Review Board at which meeting this Project is being considered. In addition, Appellants reserve all rights available under law for a judicial challenge of the granting of permission to construct the Project, should that be the final decision of the Town of Vail. Opposition to the Project is a component of the litigation currently pending between the Appellant, as plaintiff, and certain current and former members of the 1/5/2016 Board of Directors of Simba Run Condominium Association, as defendants. Such action is entitled Kleinman v. Schaff, et al., and has been assigned case number 2015 cv 1, District Court, Eagle County, Colorado. That litigation is currently scheduled for trial before Judge Gannett, Eagle County District Court Judge, in the spring of 2016. 1/5/2016 ATTACHMENT 2 TO APPEAL DATED OCTOBER 22, 2015 ROBERT AND MADELAINE KLEINMAN, APPELLANTS Nature of the Appeal, with reference to specific code sections — Health Risks, Noise and other Nuisance Laws — Included in the Project are condensers and dehumidifiers that are of large commercial grade (the dehumidifier alone has an operating weight of 7,500 pounds) and which are not suitable for installation so close to residences. The condenser operates at a sound level of 65dB, and will cycle on and off 24 hours a day, 365 days a year, creating a shrill noise at start up. The dehumidifier fan moves 8,200 cfin of air and the air supply fan uses a 10hp motor. The noise from the dehumidifier is in addition to the 65dB noise created by the condenser. These noise levels are beyond the permissible noise levels for residential areas under the State of Colorado's Noise Abatement statutes, including C.R.S. 25-12-101 through 103, et seq. The proposed operation of this equipment will also constitute a general nuisance that is actionable under the laws of the State of Colorado and the ordinances adopted by the Town of Vail. In a Supplemental Filing to the 2014 Appeal submitted to former Vail Planner Warren Campbell on October 21, 2014, Appellants noted that the Installation and Operating Manual for the Desert Aire SA Series Dehumidifiers, which is the central component for the Project, provides in Section 2. 1, at page 11.' Do not install the unit near occupied rooms such as offices or guest rooms. Even though this issue was brought to the attention of Applicant in connection with the 2014 Appeal, Applicant never justified or explained why the proposed installation of this equipment, just feet from occupied condominium units, in contravention of the manufacturer's own admonition, was appropriate. Further, in Section 2.2.3 of the Manual, at page 17, the manufacturer warns: The humid exhaust air may form an icy fog when it blasts outside during the winter. ' A copy of the Installation and Instruction Manual for the SA Series Dehumidifiers is attached hereto as Exhibit A and is hereinafter referred to as the "Manual'. 1/5/2016 That warning is applicable to all installations, wherever situated, and one can only imagine the volume of "icy fog" that will be created when blasting "humid exhaust air" into the Vail environment during a typical winter evening at 8,000 feet. Clearly, this constitutes another nuisance created by the Project for which Applicant has not offered any mediation. Legionnaires' Disease and Health Risks to Occupants and the Public - The Applicant has not addressed the risk that the Project will subject Appellants and others that come in contact with the Project to Legionnaires' Disease. As the Design Review Board is aware, an episode of Legionnaires' Disease impacted New York City just recently, sickening over 120 people and killing 12.2 This exact type of equipment has been shown to harbor the Legionella bacterium that causes Legionnaires' Disease, and the Project will put all occupants of Simba Run, particularly those that use the swimming pool, at heightened risk, and owners such as Appellants, that live immediately adjacent to the Project, at grave risk. Applicants call the Department's attention to the website for the U.K. Science and Technology Facilities Counse13 which states: 2. Scope The present code applies to the design, operation and maintenance of all water systems where there is the potential for Legionella to grow and become dispersed as a respirable aerosol, whether owned or managed by the STFC or brought onto STFC sites by facility users, tenants, contractors or other visitors. The sources include, but are not limited to, the following domestic or non domestic systems: • Fixed and mobile air conditioning, dehumidification or ventilation systems and humidifiers; (emphasis added) See, e.g., N.Y. Times edition of August 7, 2015, at: http://www.nytimes.comJ2015/08/08/n}_region/le_gionnaires- disease-outbreak-is-waning-new-York-health-official-says.htm I? r-0). ' http://www.she.stfc.ac.uk/SHE/Codes/STFC/SC38_Legionella/20977.aspx 1/5/2016 Numerous scholarly articles have also made the link between Legionnaires' Disease and dehumidification equipment, including a recent article published in the Oxford. Press Journal of Clinical Infectious Diseases, which found the bacteria for Legionnaires' Disease in the condensate from dehumidification equipment. The Journal concluded: "In addition, the following specimens tested positive for L. pneumophila by PCR: dehumidifying unit condensate, . . ." (Oxford Journals, Clinical Infectious Diseases, pp 222-228, Vol 44, Issue 2, 2015) While air conditioning cooling towers are the usual culprits in the transmission of Legionnaires' Disease, that is simply the consequence of the proliferation of such towers compared to the small number of installations similar to the Project. Nevertheless, there can be no question that equipment of the type involved in the Project is equally capable of transmitting this disease. As an example, the following is from the Hong Kong Town Health Medical Network Services: Legionella is present in our normal daily environment. Warm water provides the best conditions for its survival such as that stored in building pipes, ventilation pipes, air-conditioning ducts, drinking waterpipes, sewers, and fountains. As well, home faucets, water systems, dehumidifiers, water filters and any man-made water usage fittings that retain warm water and encourage the growth of bacteria will nurture its existence so it can also pose a threat in the comforts of your own home. (emphasis added)4 There can be no question that the Project will produce copious amounts of condensate, and that the condensate piping, drains, pans and other systems associated with this equipment are potential petri dishes for the cultivation of the Legionella bacteria. The following are from the manufacturer's Manual for this very equipment: 1. Section 2.3, dealing with Condensate Drain Piping, and stating that "Whichever type of drain your dehumidifier has, it must be trapped to prevent condensate from backing up in the drain pan." 2. Section 2.5, which cautions that when the Auxiliary Heat Coil Piping is added, which would be required in the cold climate in Vail, the owner ° The article referenced can be found at http://www.thmn.com.hk/doc/20.pdf 1/5/2016 must "size the trap for at least 2-1/2 times the design condensing rate to allow for high condensate flow on system start-up." 3. Section 3.4, which states that the owner is to "Check the condensate drain to make sure that it has been trapped and primed with water" and that the owner must "Verify that it drains freely with no leaks." 4. Section 3.5.2, which requires that the owner "Check and clean the drain pipes and blow out the condensate drain line. If the drain is plugged, water will back up into the dehumidifier and flood the mechanical room." (emphasis added). 5. Finally, the cover sheet for the Manual specifies that the dehumidifier that is the central component of the Project, will remove between 55 and 340 pounds of moisture per hour, all of which needs to be dispersed somewhere. In the United Kingdom, for facilities under its jurisdiction, the U.K. Science and Technology Facilities Counsel has mandated the routine inspection of equipment of this type to check for the presence of Legionella bacteria, an inspection protocol that is wholly outside the capabilities of personnel at Simba Run, and which is not part of any proposal submitted by the Applicant for their continued maintenance and monitoring of the health risk from this Project. The Counsel further requires the appointment of a "Legionella Responsible Person" in all installations of equipment of the type involved in the Project, with such person to be: "A person who has been formally appointed, in accordance with the HSE Approved Code of Practice, to assume managerial responsibility for implementation of the Legionella precautions and the responsibilities detailed in this SHE code." Simba Run obviously has no one on staff with the requisite training to be a "Legionella Responsible Person." In response to the recent massive outbreak of Legionnaires' Disease, New York City adopted sweeping new laws that mandate the routine inspection and disinfecting of cooling towers, and impose on the owners the entire cost of decontamination, should the Legionella bacteria be found on the site.5 It is likely that such legislation will form the model for new laws and expanded regulation 5 See, e. g., the following article from the August 5, 2015 edition of The New York Daily News, httt):Hm.nydailynews.com/new-york/bronx/86-cases-legionnaires-disease-confirmed-south-bronx-article-1.2314277. See also the following article from the Office of the Mayor, following Mayor de Blasio's signing of the new law: http://www l .nyc.gov/office-of-the-mayor/news/566-15/mayor-bill-de-blasio-signs-first-in-nation-legislation- co o l ing-to wer-maintenance#/0 1/5/2016 that will be enacted by state and federal agencies, including agencies within the State of Colorado. Even with these new regulations, ten new cases of Legionnaires' Disease were just confirmed in New Yoro, where equipment was found to be contaminated even after undergoing the routine inspections mandated by the new law, including an installation at the Albert Einstein School of Medicine, which arguably has access to the most sophisticated technicians. Recently, California reported that dozens of inmates and four staff members contracted Legionnaires' Disease from contaminated towers, confirming that the recent outbreaks are not confined to New York. Clearly, if such facilities cannot avoid contamination, there is no way that Simba Run, without any technical expertise on staff, can assure that its residents and guests can avoid becoming infected with this deadly disease as a consequence of the introduction of this equipment into the Simba Run environment. The Applicant has not (and cannot) explain how it will accomplish the necessary inspections of this equipment with the snow load that will be present in the area surrounding the Project during the winter, how it can accommodate ladders or scaffolding to enable properly trained personnel to access areas where warm water will accumulate in, on and around the Project, and how it can use the Project in a manner that will eliminate the risk of this deadly disease to Appellants and other owners at Simba Run, and their families and guests. Moreover, the Design Review Board not only failed to properly consider the health risk to Appellants and others that would come in contact with this equipment, but also the damage that would be caused to our community should there be an outbreak of this deadly disease as a consequence of the installation of this totally unnecessary and inappropriate equipment. Accordingly, the Project must be rejected, as creating an unnecessary and unacceptable public health and reputational risk to our community, a risk that is wholly disproportionate to any benefit that the Project could possibly provide to the Applicant. Design Review Standards and Guidelines — The compatibility and suitability of any proposed structure to its surroundings and to the environment are at the essence of the Town of Vail's Design Review 6 See: http://www.nyl.com/nyc/all-boroughs%news/2015/09/29/city-confirms-more-cases-of-legionnaires--disease- in-bronx.htm 7 See: http://www.foxnews.com/health/2015/10/02/cooling-towers-blamed-for-legionnaires-disease-at-califomia- prison/ 1/5/2016 Standards and Guidelines (the "Standards"). See, e.g., Paragraph A of Section 14- 10-2 of the Standards ("Structures shall be compatible with existing structures, their surroundings, and with Vail's environment"). The above -ground installation of noisy, commercial sized condensers and dehumidifiers in close proximity to residential dwellings, and with containment buildings and structures made of concrete, metal and other non -natural products, and with a construction plan that contemplates the regrading of the surrounding topography, cannot possibly be approvable under the Standards, should have been rejected on submission and on review, and must now be rejected on Appeal. The following are just some of the ways in which the Project is violative of the Standards: 1. Buildings are to fit into their sites so as to preserve the natural landforms and features intact. (Paragraph B of Standards Section 14-10-2. See also Paragraphs A, B and C of Standards Section 14-10-3). The Project will require the regrading of the site area, and the removal of mature trees and other established vegetation. We have been advised that truckloads of overburden will need to be removed from the site to accommodate the Project. 2. Ancillary buildings are to be constructed of the same or a complimentary material to the main building's exterior finish. (Paragraph C of Standards Section 14-10-10). The roof of the Project will be a Kalwall Roof or similar system, also not a favored construction material and totally inconsistent with the existing exterior materials of the present building. Note that these artificial roof panels will be fully visible from the dwelling units in the existing building. They may also reflect direct sunlight onto the adjacent dwelling units, in contravention of the requirements of Paragraph F of Standards Section 14-10-5. 3. All utility service systems shall be installed underground. (Paragraph C of Standards Section 14-10-10). While the original pool equipment was installed underground, in a manner compliant with the Standards, the Project will be fully above ground, which creates the health, noise, esthetic and other issues addressed in this Appeal. Applicant should not be allowed to construct the Project (consisting of utility service equipment or its equivalent) above ground in contravention of the letter and spirit of the Standards. 1/5/2016 No consideration by the Applicant of other less objectionable solutions — The Project has been described by the Applicant as needed to reduce damage to metal support structures in its pool building due to exposure to chlorine and chlorine derivatives. These chemicals arise from Applicant's use of traditional chlorinating products to sanitize its pool and hot tub water. The use or overuse of such products constitute obsolete technology, as there are currently superior ways to effectively sanitize pool and hot tub water without the use of such chemicals in the quantities now being used by Applicant. These include conversion to salt chlorination, where the only added chemical is sodium chloride, or the use of ultra violet disinfecting units, that significantly reduce the need for traditional swimming pool chlorine and related chemicals. The following is a partial list of web sites describing these better options, none of which were appropriately considered by Applicant: http ://www. american-pool s. com/salt-water-pool-conversion-from-chlorine/ http://www.deltauv.com/?page id=62 It should be noted that many of the indoor swimming pools in the Vail Valley have converted to salt, and promote that feature in their marketing activities. IT SHOULD ALSO BE NOTED THAT NOT A SINGLE HOTEL OR CONDOMINIUM THAT OPERATES AN INDOOR POOL IN THE VAIL VALLEY HAS INSTALLED DEHUMIDIFICATION EQUIPMENT OF THE TYPE PROPOSED TO BE INSTALLED BY APPLICANT! Applicant has been unable to explain why it must install this health risk and nuisance creating equipment while no other similar operator of an indoor pool in the entire Vail Valley has determined that such an installation is required. No legitimate need for this Project — Applicant's own consultant has advised Applicant that the damage to the pool building is far less than was originally thought when this Project was initially proposed. The pool building is now over 30 years old and is showing only minimal deterioration from the environmental and chemical interactions that the Project is designed to ameliorate. More conservative maintenance methods would address the minimal damage currently present in the pool building without the 1/5/2016 risks to health or the noise and other nuisances that would result from completion and operation of this Project. As previously noted, inexplicably, the Project is being advanced to dehumidify pool building air in Vail, Colorado, located at a height of over 8,000 feet, and in an environment which is among the driest of any populated community in the United States. That statement alone should give any reviewing agency reason to question the suitability, necessity or desirability of the Project. 1/5/2016 ATTACHMENT 3 TO APPEAL DATED OCTOBER 27, 2015 ROBERT AND MADELAINE KLEINMAN, APPELLANTS List of property owners that are the subject of this Appeal or are adjacent property owners — The applications for the Project were submitted by the Board of Directors, Simba Run Condominium Association. Their address is: Board of Directors Simba Run Condominium Association 1100 North Frontage Road Vail, CO 81657 The following are the names and addresses of the unit owners at Simba Run that are most immediately impacted by the proposed Project, other than the Appellants: Danielle Gooden Unit 2304, Simba Run Condominiums 1100 North Frontage Road Vail, CO 81657 Francisco Roman Unit 2306, Simba Run Condominiums 1100 North Frontage Road Vail, CO 81657 Ethan Schaff Unit 2308, Simba Run Condominiums 1100 North Frontage Road Vail, CO 81657 At the suggestion of the Town of Vail in connection with the 2014 Appeal, the following organizations are deemed to be entitled to notice of this Appeal. Stamped, addressed envelopes to each of the entities listed below are included with this Appeal. 1/5/2016 President Casolar Vail Homeowners' Association, Inc. 1150 Sandstone Drive Vail, CO 81657 President Savoy Villas Condominium Association, Inc. 1240 Lionsridge Loop Vail, CO 81657 President Vail Run Resort Community Association, Inc. 1000 Lionsridge Loop Vail, Colorado 81657 1/5/2016 Design Review Board ACTION FORM ��" ,! Department of Community Development TOWNj[JInT nu j%� • 75 South Frontage Road, Vail, Colorado 81657 V r tel: 970.479.2139 fax: 970.479.2452 c MnMvFLOMEW web: www.vailgov.com Project Name: SIMBA RUN DEHUMIDIFER & CONDEN DRB Number: DRB150454 Project Description: COMMON ELEMENT: INSTALLATION OF DEHUMIDIFIER AND ASSOCIATED CONDENSOR AND SCREEN WALL Participants: OWNER HURFORD, HILGE M. & JENNIFER 09/28/2015 175 E 62ND ST NEW YORK, NY 10021 ARCHITECT PIERCE ARCHITECTS 09/28/2015 Phone: 970-476-6342 1650 FALLRIDGE ROAD SUITE C-1 VAIL CO 81657 License: C000003130 APPLICANT SIMBA RUN CONDOMINIUM ASSOCI 09/28/2015 Phone: 970-476-0344 C/O FARROW HITT VAIL. CO, 81657 Project Address: 1100 LIONS RIDGE LP VAIL Location: SIMSA RUN: COMMON ELEMENT Legal Description: Lot: 6-10 Block: C Subdivision: SIMBA RUN Parcel Number., 2103-121-1300-1 Comments: Please see below. BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 10/09/2015 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of 1/5/2016 approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Cond: 202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Planner: Jonathan Spence DRB Fee Paid: $250.00 1/5/2016 0 A SA Series Energy Recovery Natatorium Dehumidifiers • Select Aire (SA) systems Installation and Operation Manual are dual refrigeration circuit, packaged dehumidifiers. • Systems remove between - 55 and 340 pounds of - - moisture per hour. • Refrigeration circuits consist of scroll compressors for high performance and long life. • Models feature 8 -row evaporator coils for high moisture removal capacity. • SA systems include an ' exclusive exhaust air heat o recovery system and patented air flow � balancing. .o • SAs dual refrigeration • ' 'O circuit design allows 5A System , staging to minimize energy consumption and optimize energy recovery. Etols EXHIBIT A 1/5/2016 ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE DESERT AIRE EQUIPMENT. SERIOUS INJURY, DEATH AND PROPERTY DAMAGE CAN RESULT FROM IMPROPER INSTALLATION/SERVICE OF THIS EQUIPMENT. HIGH VOLTAGE ELECTRICAL COMPONENTS AND REFRIGERANT UNDER PRESSURE ARE PRESENT. Desert Aire Dehumidification Equipment Standard Limited Warranty Desert Aire warrants the dehumidifying unit to be free from defects in materials and workmanship subject to the terms, conditions and limitations stated herein. TERMS Desert Aire warrants all components (except as noted) for a period of two (2) years from the date of shipment. This warranty shall be limited to the supply of new or rebuilt parts for the part which has failed because of defects in workmanship or material, and does not include the cost for labor, transportation or other costs not herein provided for. Replaced parts are warranted only for the remaining portion of the original warranty period. CONDITIONS The warranty is subject to the following conditions: 1. The unit must be properly installed and maintained in accordance with the Desert Aire "Installation and Operation Manual" provided with each unit and/or other documentation provided. 2. The Start -Up Report must be completed and returned to Desert Aire within 30 days of the start-up. 3. This warranty shall not apply to any part that has been tampered with, or has been subject to misuse, negligence or accident. A warranty can be obtained for altered equipment but only with written consent from Desert Aire. 4. The following parts and components are excluded from the warranty: belts, filters, driers, fuses and refrigerant. 5. Refrigerant coils or other components that corrode due to improperly balanced pool chemistry or corrosive air quality will not be warranted. 6. All replacements or repairs will be FOB Germantown, WI. 7. This warranty shall be null and void if defects or damages result from unauthorized opening of the refrigerant circuit, tampering with factory set controls, or operating outside the original design conditions. 8. Desert Aire shall not be liable for labor costs incurred in diagnosing the problem, or the removal or replacement of the part or parts being repaired. 9. Desert Aire must preauthorize all warranty coverage described herein. Desert Aire - SA Manual 3 1/5/2016 Extended Warranty: Your Desert Aire unit may have extended warrantees beyond this Standard Limited Warranty document. Extended warrantees are only available at the time of the purchase of the original equipment. These extended war- rantees are covered under a separate document and their terms and conditions are separate from this document. It is mentioned in this document for informational purposes only. Any and all incidental or consequential damages are expressly excluded from this warranty. Some states do not allow the exclusion of incidental or consequential damages for personal injury, so the above limitations may not apply to you for certain damages. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. No person or representative is authorized to make any warranty or assume any liability not strictly in accordance with the aforementioned. Inquiries regarding warranty matters should be addressed to: Desert Aire Corp c/o Service Manager N120 W18485 Freistadt Road Germantown, WI 53022 PH: (262) 946-7400 FAX: (262) 946-7401 E-MAIL: service@desert-aire.com Additional copies of this manual can be purchased for a nominal fee from Desert Aire. Submit requests to the contact information listed above. 4 Desert Aire - SA Manual 1/5/2016 Safety Labels are used throughout this manual. They comply with the ANSI Z535.4 Standard. Please be familiar with the following labels and their definitions. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible death or injury. ff DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! CAUTION I Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. Caution used without the safety alert symbol indicates a CAUTION potentially hazardous situation which, if not avoided, could result in property damage. Desert Aire - SA Manual 5 1/5/2016 Desert Aire - SA Manual 1/5/2016 TABLE OF CONTENTS 1 Introduction...................................................................................................................... 9 1.1 Inspection............................................................................................................... 9 1.2 Damage Claims...................................................................................................... 9 1.3 Rigging................................................................................................................... 9 1.3.1 Rigging the Dehumidifier............................................................................. 9 2 Installation....................................................................................................................... 11 2.1 Position and Service Clearance............................................................................. 11 2.2 Outdoor Air Duct.................................................................................................... 15 2.2.1 Outdoor Air Duct Unit without Integral Exhaust ......................................... 15 2.2.2 Outdoor Air Duct Unit with Integral Exhaust .............................................. 17 2.2.3 Exhaust Duct Unit with Integral Exhaust ................................................... 17 2.3 Condensate Drain Piping....................................................................................... 18 2.4 Pool Water Piping................................................................................................... 20 2.5 Auxiliary Heat Coil Piping....................................................................................... 22 2.6 Remote Condenser (Optional).............................................................................. 23 2.7 High Voltage Wiring............................................................................................... 24 2.8 Controls and Sensors............................................................................................ 25 2.8.1 Air Temperature/Humidity Sensor............................................................. 25 2.8.2 Water Temperature Sensor....................................................................... 25 2.8.3 Installation of Sensors for the SelectAireTM with Integral Exhaust Fan ..... 25 2.8.3.1 Indoor Static Sensor Installation.................................................. 26 2.8.3.2 Outdoor Static Sensor................................................................... 26 2.8.4 Installation of Optional VOC Monitoring Sensor ......................................... 28 2.9 Auxiliary Heating Control Wiring............................................................................ 28 2.9.1 Auxiliary Heating - Dry Contact Closure .................................................... 29 2.9.2 Auxiliary Heating - Proportional Signal ...................................................... 29 2.10 Auxiliary Pool Water Heating.................................................................................. 29 2.11 Smoke Alarm Interlock........................................................................................... 30 3 Start -Up Procedures..................................................................................................... 31 3.1 Preliminary Inspection............................................................................................ 31 3.2 Airflow Balancing.................................................................................................... 32 3.2.1 Airflow Setup of SelectAireTM without Integral Exhaust Fan ...................... 33 3.2.2 Airflow Setup of SelectAireTM with Integral Exhaust Fan ........................... 35 3.2.3 Final Air Balancing..................................................................................... 38 3.3 Refrigeration Testing.............................................................................................. 43 3.4 General Testing..................................................................................................... 45 3.5 Routine Maintenance Schedule............................................................................. 45 Desert Aire - SA Manual 7 1/5/2016 8 Desert Aire - SA Manual 1/5/2016 3.5.1 Service Every Month................................................................................. 45 3.5.2 Service Every Six Months......................................................................... 46 4 Troubleshooting............................................................................................................. 47 4.1 The Blower Does Not Run...................................................................................... 47 4.2 The Compressor(s) Do Not Run............................................................................. 47 4.3 High Pressure Alarms / Readings Above 575 PSIG............................................... 48 4.4 Low Pressure Alarms / Evaporator Coil Icing......................................................... 48 4.5 The Pool Water Is Too Cold................................................................................... 49 5 Appendix.......................................................................................................................... 51 5.1 Compressor Failure................................................................................................ 51 5.1.1 Compressor Replacement......................................................................... 51 5.2 Recommended Duct Design................................................................................... 54 5.3 Pool Water Chemistry ............................................................................................. 55 5.4 Recommended Controller Settings......................................................................... 55 5.4.1 Controller Set Points................................................................................. 55 5.5 System Operating Modes....................................................................................... 55 5.6 Component Replacement, Charge, Evacuation, & Leak Instructions ..................... 56 5.7 System Rating Plate............................................................................................... 60 5.8 Start -Up Supervision Supplemental Information.................................................... 60 5.9 System Start -Up Report......................................................................................... 63 Start -Up Report...................................................................................................... 64 Compressor Replacement Form............................................................................ 69 8 Desert Aire - SA Manual 1/5/2016 1 Introduction Desert Aire dehumidifiers are designed to provide years of reliable service when installed properly. Read these instructions carefully before you install the dehumidifier. 1.1 Inspection Desert Aire inspects and tests each dehumidifier before it leaves the factory so that you receive a quality piece of equipment. Unfortunately, equipment may become damaged in transit. Inspect the dehumidifier carefully before signing the receiving papers. Check for both visible and concealed damage. Use a halogen leak detector to check the piping for refrigerant leaks. 1.2 Damage Claims If the dehumidifier has been damaged, document the extent of the damage. Take pictures if possible. Next, obtain a claim form from the carrier. Promptly fill out and return the form. Carriers may deny claims that you have not filled out within a week of delivery. Notify Desert Aire of any damage. 1.3 Rigging 1. Failure to observe rigging instructions may lead to equipment damage, personal injury or death. 2. Lifting method and procedure must comply with all local and national codes and regulations. 3. The use of safety slings in addition to lifting lugs is required. 4. Do not lift the dehumidifier in high winds or above people. Desert Aire dehumidifiers are solidly built and can be very heavy. Avoid personal injury and damaged equipment by planning the installation carefully. Use moving equipment whenever possible. 1.3.1 Rigging the Dehumidifier Desert Aire dehumidifiers are equipped with four or more lifting lugs. Use spreader bars and safety straps when you use these lugs for rigging. • Utilize all of the lifting lugs provided when hoisting unit. • Test -lift the dehumidifier to verify that it is properly balanced. • Do not lift the dehumidifier in high winds or above people. • The top panels are not designed to support the weight of persons. The top panels are weather proofed and excessive weight may cause water to penetrate through cracked seams. Damage incurred through caved or distorted top panels will not be covered under warranty. If you must walk on the top panels, carefully walk on the edges where structural integrity is greatest. Desert Aire - SA Manual 9 1/5/2016 Large System Rigging Notes: 1. The number of lifting points will vary between units. All lifting points must be used to lift unit. 2. Spreader bar must be used. Unit top panel 2x4 E is not designed to handle loading. 3. Lifting method/procedure to comply with all local and national regulations. 4. Use safety slings (not shown) in addition to lifting lugs. 5. Be sure that the lifting hooks do not contact the sides of the unit. 6. Use appropriate lifting strategy for unit. 0036.cdr Figure 1 - Typical Rigging for the SA Dehumidifier 1. Do not tip the dehumidifier on it's side. 2. Avoid dropping the unit down stairways or subjecting it to severe mechanical shock. 10 Desert Aire - SA Manual 1/5/2016 2 Installation Manual applies to standard unit configurations only. 2.1 Position and Service Clearance Desert Aire dehumidifiers require routine maintenance to operate efficiently. • Allow a minimum of 36 inches of clearance around the service side of the dehumidifier for piping, electrical connections, and service access. Install the unit on a sturdy, level mounting base or platform that will prevent vibration and sound transmission. Never install the dehumidifier on a wooden platform without consulting the design engineer for spring isolation requirements and sound control materials. Do not install the unit near occupied rooms such as offices or guest rooms. Level the dehumidifier to ensure proper condensate drainage. Install blocks under the unit if necessary to provide clearance for the condensate trap. Install blocks underneath each corner and each lifting lug. Figure 2 - Dehumidifier with Blocks Installed for Trap Clearance • Install outdoor dehumidifiers equipped with an outdoor air intake away from plumbing vents, furnace flues, or equipment which could contaminate the air supply. • If the dehumidifier is to be mounted on a roof curb, make sure that the curb has been properly mounted and supported. Place gasketing around the perimeter of the curb before setting the dehumidifier in place. This will help prevent air or water leaks. • You must not install an indoor rated dehumidifier in an unconditioned space or where ambient temperatures can fall below 45°F. If you must install the dehumidifier outside or in an unconditioned space, you must use an outdoor rated dehumidifier. Desert Aire equips outdoor -rated units with weatherproofing and thicker insulation. You can determine if your unit is outdoor -rated by inspecting the unit rating plate. (See Section 5.7 in the Appendix for details.) • Duct design and installation should conform to ASHRAE and SMACNA low velocity duct standards. See Section 5.2 in the Appendix for additional duct recommendations. Desert Aire - SA Manual 11 1/5/2016 REMOTE CONDENSER 12 Desert Ai,. - SA Manual WEATHER-PROOF INTAKE FOOD Mechanical Room MOTOR OPERATED DAMPER INSULATED OUTSIDE AIR INTAKE DUCT, SIZE FOR CODE REQUIREMENTS) -------------------- SKYLIGHT -------------- ------------------- SKYLIGHT JR Pool Room MECHANICAL EXHAUST WITH BACK -DRAFT DAMPER (WALL OR ROOF MOUNTED) NOTE! CAPACITY SHOULD NOT EXCEED INTAKE VOLUME. Figure 3 - Basic Pool Room Layout 1/5/2016 DS' T EI B IN -11 TURNING VANES IN ALL ELBOWS. Crr EW _;0P LOCATE ANODIZED ALUMINUM UEX'BUE NEOPRENE RETURN AIR GRILLE AS HIGH DUCT CONNECTOR AS PQS.I.UE IN ROOM Am 'TMM� T L 4 --------- E2 TEMPERATURE AND HUMIDITY CONTROLS -------------------- SKYLIGHT -------------- ------------------- SKYLIGHT JR Pool Room MECHANICAL EXHAUST WITH BACK -DRAFT DAMPER (WALL OR ROOF MOUNTED) NOTE! CAPACITY SHOULD NOT EXCEED INTAKE VOLUME. Figure 3 - Basic Pool Room Layout 1/5/2016 Use turning vanes whenever the duct makes an abrupt turn, especially in the return air duct. Poor return air distribution will reduce the moisture removal. ANODIZED ALUMINUM RETURN AIR GRILLE LOCATE AS HIGH AS POSSIBLE RETURN AIR DUCT FILTER RACK FLEXIBLE DUCT CONNECTIONS CONDENSATE PIPING P.C.D. COATED SPIRAL GALVANIZED PIPE Figure 4 - Typical In -Ground Duct Layout • You may use galvanized sheet metal ducts for all but underground installations and severely corrosive environments. • Do not use fiberglass duct boards or acoustic duct liner for air distribution in highly humid applications, such as pool room dehumidification. • If a duct must be installed in an unconditioned area, or if you are installing an outdoor air intake duct, insulate it with two inches of fiberglass duct wrap with an intact vapor barrier. • Direct the supply air toward skylights, exterior walls and windows, and spectator areas. Since air movement will increase the evaporation rate of the pool, direct the supply air grilles away from its surface. Desert Aire - SA Manual 13 1/5/2016 SKYLIGHT ANODIZED At SIDEWALL RE DESERT AIRE ANODIZED Al RETURN AIR LOCATE AS H RETURN AIR I FLEXIBLE DU, CONNECTION Figure 5 - Soffit Duct Layout with Skylight Grille ANODIZED ALUMINUM CEILING DIFFUSER VAPOR BARRIER WINDOW • Install return air grilles or louvers as high as possible in the enclosure. Normally, one centrally -located grille will be adequate. Avoid under sizing this grille or "short-circuiting" of air with nearby supply registers. • Select grilles and diffusers for low static pressure loss and proper throw and CFM rating. • Keep the noise criteria levels of the grilles between 35 and 45 d6. • Use anodized aluminum grilles to prevent premature corrosion. 14 Desert Aim - SA Manual 1/5/2016 2.2 Outdoor Air Duct Standard Desert Aire dehumidifiers are equipped with an opening which will draw outdoor air into the conditioned space. This will help you to comply with ASHRAE Standard 62, which requires the introduction of outdoor air into commercial buildings. The SA controller features a seven-day programmable time clock. The clock will open and close the outdoor air damper based on the building occupancy schedule. Note that condensation may occur when cold outdoor air is mixed with warm, humid return air inside of the dehumidifier. During the winter months, this moisture can freeze and cause serious damage to the equipment. Desert Aire dehumidifiers are equipped with an internal temperature sensor which will close the outdoor air damper if it senses freezing temperatures inside the unit. If outdoor temperatures in your area drop below 32°F, and outdoor air code compliance is required at all times, you must install a preheating coil. System failures caused by improper outdoor air duct installations are not covered by the Desert Aire warranty. The ducting method you use depends on the SA type of dehumidifier you have. 2.2.1 Outdoor Air Duct Unit without Integral Exhaust There are three possible configurations for the outdoor air opening: 1. The SA units without Integral Exhaust have a duct connection with outdoor air damper and actuator between the evaporator and the reheat condenser coils. The unit controller will energize a set of dry contacts during occupied times. Use these dry contacts to control an additional outdoor air damper if required and/or the exhaust blower. The exhaust blower and the outdoor air louvers, filters, additional dampers, and actuators must be field -supplied. O/A Duct Connection w/C Field -Installed Duct - ---- -------------------------------------------- Filters, Dampers, & Louvers by Others Figure 6 - Indoor Dehumidifier with Outdoor Air Duct Connection with Damper Desert Aire - SA Manual 15 1/5/2016 2. An optional module can be provided which contains filters and a factory -installed damper and actuator. This module, which is designed for indoor installations, has a flanged opening for a field -installed outdoor air duct. The unit controller will energize a set of dry contacts during occupied times. Use these dry contacts to control the exhaust blower. Outdoor air louvers and the exhaust blower must be field -supplied. Field -Installed Duct -------------------------------- Louvers by Others Figure 7 - Indoor Dehumidifier with Filter and Damper Module An optional module can be provided, which contains filters and a factory -installed damper and actuator. This module, which is designed for outdoor installations, has an outdoor air intake protected by a weather hood. The unit controller will energize a set of dry contacts during occupied times. Use these dry contacts to control the field -supplied exhaust blower. Figure 8 - Outdoor Dehumidifier with Filter and Damper Module The outdoor air duct used for options 1 and 2 must be insulated to prevent condensation from forming on it during the winter. Since cold outdoor air can cause moisture to condensate and freeze on surfaces when it mixes with the warm, humid return airstream, you must preheat the outdoor air whenever possible. 16 Desert Aire - SA Manual 1/5/2016 2.2.2 Outdoor Air Duct Unit with Integral Exhaust There are two possible configurations for the outdoor air opening: 1. The standard SA unit with Integral Exhaust contains a module which handles outdoor makeup air and exhaust air. This factory -installed module includes filters, dampers, actuators, and an exhaust blower. The unit controller will open the dampers during occupied times. This module, which is designed for indoor installations, has flanged openings for the outdoor and exhaust air ducts. The ductwork and louvers must be field -supplied. <=C ----------------------- ------------ .......... ...... - ---------- Figure 9 - Indoor Dehumidifier Showing Outdoor Air and Single Exhaust Ducts 2. The standard SA unit with Integral Exhaust contains a module which handles outdoor makeup air and exhaust air. This factory -installed module includes filters, dampers, actuators, and an exhaust blower. This module, which is designed for outdoor installations, has an outdoor air intake protected by a weather hood. 2.2.3 Exhaust Duct Unit with Integral Exhaust There are two possible configurations for the exhaust air opening: 1. The module ordered for an outdoor unit discharges the exhaust air to the atmosphere. No duct connection is required. 2. The module ordered for an indoor unit will have one or two discharge flanges, depending on the volume of exhaust air. You must duct the exhaust air to outside the building. The combined resistance of the duct and the discharge grille must not exceed 0.5" W.C. The humid exhaust air may form an icy fog when it blasts outside during the winter. Install the outlet grille in a location where this fog will not damage the building or create a safety hazard. Desert Aire - SA Manual 17 1/5/2016 a�;---------- ------- Figure 10 - Indoor Dehumidifier Showing Outdoor Air and Dual Exhaust Ducts 2.3 Condensate Drain Piping The condensate drain connection on the standard Desert Aire SA series dehumidifiers is a 1-1/2" ID PVC stub which penetrates the base rail of the unit. Figure 11 - SA Standard Condenser Drain Location An SA series dehumidifier ordered for roof curb mounting has its drain connection on the underside of the unit to help prevent freezing. This drain has a 1-1/2" MPT fitting. 8 Desert Aire - SA Manual 1/5/2016 Figure 12 - SA Roof Curb Unit Showing Condensate Drain Location Whichever type of drain your dehumidifier has, it must be trapped to prevent condensate from backing up in the drain pan. The cabinet of the dehumidifier is under negative pressure whenever the supply blower is running. If you do not trap the drain, condensate will be sucked into the cabinet, where it may cause premature corrosion and property damage. T 1 r Figure 13 - Sectional View of Condensate Trap Requirements Trap the condensate connections as shown in Figure 13. The P -trap dimensions in Figure 13 are sized for a maximum return air static of 2.0" W.C. If your return air static exceeds this specification, consult Desert Aire for help in resizing the P -trap. You may also need to install a cleanout tee or plug near the trap. Note that the drain opening in the drain pan is off -center to simplify its cleaning and servicing. Once you have designed and installed the trap, follow this sequence: 1. Connect the trap to a main drain line with 1/4" of downward pitch per linear foot of run. Desert Aire - SA Manual 19 1/5/2016 2. Support the drain pipe every five feet to prevent sagging. 3. After you install the drain piping, prime the trap by pouring water into the drain pan of the dehumidifier. Condensate drain lines installed in an unconditioned space must be heat taped to prevent freezing. Check the heat tape yearly before winter operation. 2.4 Pool Water Piping The DesertAire dehumidifier may be equipped with an optional pool water heating condenser. Use copper or schedule 80 CPVC pipe and fittings to adapt to the water circuit of the dehumidifier. See Figure 14 for recommended pool water piping. Note that this figure is intended to be a general guide only, and may not match your installation exactly. All piping must meet state and local codes. 20 Desert Aire - SA Manual 1/5/2016 1 Supply Air 2 Duct Heater (Gas, Electric, Etc.) 3 Flex Duct Connector 4 Piping to Remote Condenser 5 Desert Aire Dehumidifier 6 Filter Rack Assembly with Filters 7 Return Air 8 Vibration Isolators 9 P -Trap 10 Base (If Required) 11 Check Valve 12 Ball Valve 13 Flow Meter 14 Main Pool Heater 15 Auxiliary Pump 16 Filter Assembly 17 Main Pool Pump 18 Aquastat Sensor (Dry Well) 19 Water Inlet 20 Water Outlet Figure 14 - Typical Pool Water Piping Diagram Desert Aire - SA Manual 21 1/5/2016 • You may not need an auxiliary pump if the main pool pump has sufficient pressure to overcome the elevation and the resistance of the water piping to the dehumidifier. If the main pump will be cycled on and off, you must use an auxiliary pump. • If you use an auxiliary pump and you intend to cycle the main pump, you must size the auxiliary pump to overcome the resistance of the main pool piping and filters. • The dehumidifier is equipped with a built-in flow switch. If there is no water flow to the unit, the refrigeration circuit will be locked out of the pool water heating mode. All other modes, such as dehumidification and cooling, will function normally. Desert Aire recommends continuous water flow to the unit to prevent vapor lock, pump cavitations, and nuisance head pressure trips. • You must install an air eliminator at any high points in the pool water piping. Excess air in the Desert Aire pool water condenser will cause inadequate pool heating and high operating temperatures and may shorten the life of the dehumidifier. Dehumidifiers equipped with the pool water heating option come with a factory -supplied water temperature sensor and an aqua stat well. See Section 2.8 for details on control and sensor location. Water Circuit Size Water Flow Rate and Pressure Drop: Pool Water Flow Rate and Pressure Drop: Spa 9/10 Ton 20 GPM @ 25 ft W.C. 27 GPM @ 35 ft W.C. 15 Ton 30 GPM @ 25 ft W.C. 40 GPM @ 35 ft W.C. 20 Ton 40 GPM @ 25 ft W.C. 53 GPM @ 35 ft W.C. 25 Ton 50 GPM @ 25 ft W.C. 67 GPM @ 35 ft W.C. 30 Ton 60 GPM @ 25 ft W.C. 80 GPM @ 35 ft W.C. Figure 15 - Standard Unit Water Flow Rates (for Units Equipped with this Option) 2.5 Auxiliary Heat Coil Piping The Desert Aire dehumidifier may be equipped with an optional hot water or steam air heating coil. This coil, when properly sized, will provide space heating during the winter months. • You must use proper practice when you design and install the coil piping to prevent poor coil performance, shortened service life, or damage to the coil. • The supply connections must not be supported by the coil headers. • The control valve should be sized according to the pressure and flow rate requirements, not the coil connection size. • On steam systems, size the trap for at least 2-1/2 times the design condensing rate to allow for high condensate flow on system start-up. • On steam systems, use strainers, dirt pockets, and isolation valves to prevent clogging the control valve and to simplify service. • Install swing joints in the connection piping to prevent damage to the coil header for thermal expansion. • Use a backup wrench on the pipe stubs when attaching connections to prevent damage to the header. 22 Desert Aire - SA Manual 1/5/2016 2.6 Remote Condenser (Optional) SA Series Remote Condenser Line Size (R -410A) Model Circuit A Circuit B Hot Gas Line (Discharge) Liquid Line (Return) Hot Gas Line (Discharge) Liquid Line (Return) SA18 1-1/8 5/8 1-1/8 5/8 SA20 1-1/8 5/8 1-1/8 5/8 SA24 1-1/8 5/8 1-3/8 3/4 SA30 1-3/8 3/4 1-3/8 3/4 SA35 1-3/8 3/4 1-3/8 7/8 SA40 1-3/8 3/4 1-3/8 7/8 SA45 1-3/8 7/8 1-3/8 7/8 SA50 1-3/8 7/8 1-5/8 1-1/8 SA60 1-5/8 1-1/8 1-5/8 1-1/8 Figure 16 - Remote Condenser Line Size Summary (for Units Equipped with this (Option). Performance rated at return air conditions of 82°F/60%RH, 50' Actual line length/62.5' Equivalent line length. Desert Aire SA series dehumidifiers are pre -charged with enough refrigerant to fill the Remote Condenser and up to 50 feet of refrigerant lines. No additional charge is required unless your line set is longer than 50 feet. CONSULT WITH DESERT AIRE IF YOU MUST INSTALL THE REMOTE CONDENSER MORE THAN 100 FEET BELOW OR 50 FEET AWAY FROM THE DEHUMIDIFIER UNIT. Check Rating Plate label or consult factory in regards to specific charge and/or remote condenser line sizes. Support and clamp condenser tubing at regular intervals. Maximum span between clamps should be limited to the following: Tube Size Span Between Clamps 1/2" — 7/8" 5' maximum 1-1/8" 6' maximum 1-3/8" 7' maximum 1-5/8" 8' maximum The first clamp after the cabinet penetration should also be located such that the maximum span is maintained. Provide means of preventing dissimilar metal contact such as copper clamps, plastic coated hangers, or similar. Rubber isolation at connection is recommended for applications where there may be sensitivity to noise or vibration. Follow ANSI/MSS SP -69 clamping guidelines. Desert Aire - SA Manual 23 1/5/2016 Consider the use of U -Loops or Z -Bends for extended lengths of straight tubing subject to wide ranges in temperature conditions. Refer to ASHRAE Handbook HVAC System and Equipment for examples. Ensure tubing is centered within pipe seal grommet at cabinet penetration before fully tightening any field installed clamps and brackets. Forces occurring during mode shifts may move piping slightly. After tightening check to ensure there is a minimum of 1/2" clearance around all field installed tubing to any structure or other obstruction. 2.7 High Voltage Wiring You must follow all local codes when you connect the high-voltage wiring to the dehumidifier. Attach the wires to the three -pole power block mounted on the electrical panel. Test the phasing by "bumping" the blower contactor. Verify that the blower rotates in the proper direction. If it turns the wrong way, switch any two of your wires at the power block. 1. Disconnect power before servicing. The unit contains high voltage wiring and moving parts which may cause serious injury or death. 2. Failure to properly wire the dehumidifier may create the possibility of shock and can lead to premature system failure. Ground Lug Factory Supplied Wiring Ground Wire L1 L2 L3 Main Power Supply from Disconnect Box Main Power Block in Unit Figure 17 - A Typical Desert Aire Three -Phase Power Block Some equipment may contain a variable speed drive for the supply fan. The fan will run the correct direction regardless of the input power. In these cases, the compressor must be "bumped" to determine if it is pumping correctly. Use the controller display to view the analog inputs and briefly energize one of the compressor contactors. The discharge pressure should increase and the suction pressure should decrease when phasing is correct. Do not run the compressors in reverse rotation for an extended period of time as damage will result. 24 Desert Aire - SA Manual 1/5/2016 2.8 Controls and Sensors The standard Desert Aire SA series dehumidifiers are controlled by a microprocessor controller. This controller monitors conditions such as room humidity and temperatures and controls the dehumidifier accordingly. A separate controls manual has been provided. Refer to this separate manual for controller specifications, operation, and options. 2.8.1 Air Temperature/Humidity Sensors Duct Mount Temperature/Humidity Sensor Install the duct -mount sensor in the return air duct upstream of any outdoor air intakes. • Do not mount the sensor in a section of duct where false readings may occur due to dead air regions, solar heat gain, or thermal losses in winter. Do not mount the sensor where water is likely to drip on it. Liquid moisture will ruin the humidity sensing element in the sensor. Wall Mount Temperature/Humidity Sensor If your dehumidifier was ordered with a wall -mount humidity and temperature sensor, mount the sensor about five feet above the pool deck on an interior wall with natural air circulation. Avoid the following locations: • Hot spots near concealed heating pipes, warm air ducts, supply register outlets, or solar radiation. • Cold spots due to a cold wall or drafts from stairwells, doors, windows, or supply register outlets. • Dead spots such as behind doors or in corners where room air cannot circulate freely. A supply air temperature sensor and duct holder is also provided to be installed downstream of any field provided heaters. Mount this in the supply duct and seal the penetration. Install at least 5 ft. downstream of all heaters and not in the "line of sight' of the heater elements as the radiant heat produced by the heater may affect the reading. 2.8.2 Water Temperature Sensor Desert Aire dehumidifiers ordered with the pool water heating option are supplied with a water temperature sensor and an aqua stat well. • Screw the well into an adapter fitted into the pool water piping. The well is equipped with a 1/2" MPT connection. • Install the sensor upstream from the dehumidifier or the auxiliary pool water heater. The sensor must be installed in a location where it will accurately sense the pool water temperature. This means you must have continuous water flow at the sensor location. 2.8.3 Installation of Sensors for the SelectAireTM with Integral Exhaust Fan In pool applications, it is critical to maintain negative space pressurization relative to adjacent spaces and the outside ambient. This prevents moisture laden air from being driven into the wall Desert Aire - SA Manual 255 1/5/2016 cavities and condensing. The SelectAireTM unit includes provisions to measure the differential in static pressure between the space and the outdoors and helps to maintain this negative static pressure in the space, 2.8.3.1 Indoor Static Sensor Installation The indoor static pressure sensor should be mounted in a location not subject to damage from occupants. Place the sensor as far as practical from doors, grilles, and operable windows that may cause pressure fluctuations. Locate a minimum of 3' above the floor level in the pool area. Note that in rooms with extremely high ceilings (greater than 30) it is preferable to locate the sensor a minimum of halfway up the wall. This is due to building stack effect where the pressure may become higher at the ceiling than at the floor. The sensor can be mounted directly to drywall or to a standard single gauge electrical box. 50' of 1/8" clear pressure tubing is supplied with the sensor. Route the tubing such that it will not be subject to damage. Do not directly attach the tube to surfaces that may become very cold such as suction lines or supply ducts as condensation may occur in the tubing. Connect the tubing to the static pressure differential transducer in the unit. The correct port is labeled for the indoor air sensor. Figure 18 - Indoor Static Pressure Sensor (rear view) 2.8.3.2 Outdoor Static Sensor A complication in measuring the building static pressure is the dynamic action of the wind. Measuring the wind's pressure instead of the true outdoor static pressure will alter the actual static pressure reading. Proper mounting of the outdoor static sensor will help ensure accurate readings. The outdoor air static pressure sensor should be mounted at least 12 inches above 26 Desert Aire - SA Manual 1/5/2016 surrounding obstacles and a minimum of 24 inches from a wall or Air Handling Unit. Do not mount under awnings or other projections within fifteen feet. Do not mount near economizers, intakes or exhaust fans, or barometric dampers. Do not mount within 10' of building corners or parapet walls. Figure 19 - Outdoor Static Pressure Sensor A detailed drawing of the outdoor static sensor assembly is included with the package. Assemble mounting bracket and tubing per this drawing. 50' of 1/8" opaque pressure tubing is supplied with the sensor. Route the tubing such that it will not be subject to damage. Do not directly attach the tube to surfaces that may become very cold such as suction lines or supply ducts as condensation may occur in the tubing. It is recommended that all of the tubing length be used as this helps buffer any fluctuation in the sensor readings due to wind gusts. Excess tubing should be coiled at some convenient location rather than cut. Connect the tubing to the static pressure differential transducer in the unit. The correct port is labeled for the outdoor air sensor. Closely observe that the indoor static pressure sensor and outdoor static pressure sensor are installed on the proper ports as labeled. Desert Aire - SA Manual 27 1/5/2016 2.8.4 Installation of Optional VOC Monitoring Sensor Desert Aire offers an optional VOC monitoring sensor that can trigger a greater flow rate of outdoor air when indoor contaminants reach a user determined concentration. This sensor can be mounted in a space that represents the typical breathing zone for occupants. The back mounting plate is suitable for mounting on a 2" x 4" J -Box or directly to drywall. Screws are provided. Three wires are required and terminals on the sensor can accommodate 16 to 22 AWG. 18 AWG wire can be used up to 500 ft. run. Terminate wires as shown on the low voltage diagram. Check to ensure that the sensor output has been set for 0-5 VDC output. The J3 jumper should be set in the storage position. See data sheet supplied with sensor for additional details. 2.86 in. (72.7 mm) Figure 20 - VOC Monitoring Sensor 1m) Closed Cell Foam 2.9 Auxiliary Heating Control Wiring Note: You must use the Desert Aire control system to control or interlock with the room heating system. This prevents wide fluctuations in room air temperature. It also prevents the heater from trying to heat the room while the dehumidifier is running in cooling. Desert Aire will provide a signal to operate the auxiliary pool room heating system. The signal can either be a binary dry contact closure or a proportional voltage with an optional dry contact closure to operate an interlock or pump. The heating output type is pre-set from the factory based on the request at the time of order. 28 Desert Aire - SA Manual 1/5/2016 2.9.1 Auxiliary Heating — Dry Contact Closure Desert Aire will provide a dry contact closure to interlock with the building heating system. This contact closure is normally used to interlock with a gas or electric duct heater which has its own power supply transformer. When the room air temperature drops below the set point, the dry contact will close to energize the auxiliary heater. See the dehumidifier wiring diagram for details. 2.9.2 Auxiliary Heating — Proportional Signal Desert Aire will provide a proportional signal to modulate a heating coil control valve on units equipped with an integral heating coil. This signal is reverse acting or direct acting depending on the settings in the controller. It is critical that units with hot water and steam coils be set properly for freeze protection. See controller manual for details on the settings and outputs. The SA dehumidifiers are equipped with a local man -machine interface on the face of the unit controller located inside the electrical box of the unit. A separate, optional remote display terminal can be ordered for service or remote access. See the controller manual for details on wiring and environmental limits. Most proportional valves have either three or four terminals for field -installed wiring. • Four -terminal valves have two terminals for 24 VAC power and two terminals for the signal input. • Three -terminal valves have one terminal for the "hot" 24 VAC input, a second terminal for the "positive" signal input, and a third, common terminal for the "neutral" 24 VAC input and the "negative" signal input. You must follow the instructions included with the valve cut sheet. Observe the proper polarity, or you may damage both the valve and the Desert Aire controller. See the unit wiring schematics for information on signal wire connection points. When the proportional signal is ordered, the binary heating output acts as an interlock. This can be used to activate a pump, valve, or interlock that needs to be coordinated with the proportional heating signal. The contact rating is shown on the electrical schematic. Use a transformer and relay to energize loads that are higher than the contact rated current draw or power. 2.10 Auxiliary Pool Water Heating A properly sized Desert Aire dehumidifier equipped with the pool water heating option can maintain the pool water temperature under normal conditions. However, like any refrigerated dehumidifier, the Desert Aire unit may require days to heat a recently -filled pool by itself. For this reason, you should install an auxiliary pool heater. Desert Aire dehumidifiers ordered with the water heating option are provided with a set of dry contacts for controlling an auxiliary pool water heater. The dehumidifier will be the primary source of water Desert Aire - SA Manual 29 1/5/2016 heating. If it cannot keep up with the demand for pool heat, the Desert Aire controller will then energize the auxiliary water heater. Note: Do not use the aqua stat mounted on the auxiliary heater for temperature control. This can lead to excessive water temperature fluctuation. It may also permanently prevent the dehumidifier from heating pool water if the set point of the heater aqua stat is higher than the water heating set point of the dehumidifier. 2.11 Smoke Alarm Interlock Desert Aire SA series dehumidifiers are equipped with a set of terminal blocks for interlocking with the smoke alarm (alarm provided and installed by others). The smoke alarm contacts must be rated for at least 15 amps at 24 VAC. The contacts must break when smoke is present. This will shut off the blower(s) and compressors. See the dehumidifier wiring diagram for connection details. 30 Desed Aire - SA Manual 1/5/2016 3 Start -Up Procedures Read this section thoroughly before attempting to commission the Desert Aire dehumidifier. A complete start-up will minimize operational problems and expensive callbacks. The start-up will be quicker and easier if there is a heat and humidity load present in the space. Energize any auxiliary air and pool water heaters before the start-up so that the air and water are at their design temperatures. Crankcase heater should be energized for 24 hours before refrigeration system is allowed to operate. 3.1 Preliminary Inspection Verify that all contractors have completed their work. Find the Desert Aire "SA Start -Up Report", which is located near the back of this manual. You must fill out the start-up report to validate the dehumidifier warranty. Check the following items: • Before starting unit, remove wooden shipping blocks found beneath compressor(s). • Before starting unit, remove shipping restraining brackets on supply blower equipped with the spring isolation base, if applicable. • Verify that the incoming power supply matches the rating plate of the dehumidifier. The fused disconnect and the power supply wiring must be rated to handle the minimum ampacity rating printed on the rating plate. • With the power supply disconnected and locked, tighten all field and factory electrical connections. • Check and adjust the belt tension for proper deflection at the midpoint of the blower belt(s). • The deflection is based on the belt length. The belt length can be found on the belt itself. Determine the force using the Belt Deflection Force table on page 32. Specified Belt Deflection Belt Length Deflection 25" to 50" 0.25" 51" to 70" 0.375" 71 "to 110" 0.625" Figure 21- Specified Belt Deflection Table Desert Aire - SA Manual 31 1/5/2016 Belt Deflection Force New Belt Force (lbs.) Used Belt Force (lbs.) HP 1 Belt 2 Belts 3 Belts 1 Belt 2 Belts 3 Belts 0.5 3 2-2.5 1 1.5 2 3 7 5-6 5 7.5 10 12 7 9-10 5-6 15 20 25 12 8-9 30 12 8-9 40 Figure 22- Belt Deflection Force Table • Check for proper phasing (three-phase units) by momentarily energizing the supply air blower. If the blower runs backwards, switch two of the power supply wires at the power block of the dehumidifier. When the blower rotates properly, the remainder of the motors in the system will be properly phased. • Check for proper phasing of the optional remote condenser power supply. The fans will blow air vertically upward when they are phased correctly. • Inspect the air filters in the dehumidifier. Replace them if necessary. • Check the pool water piping on units equipped with the water heating option. Inspect for leaks and proper installation of components. Verify that the auxiliary pump operates, if one is used. Purge all air out of the pool water piping. • Check the heating control valve and piping on dehumidifiers equipped with an optional hot water or steam heating coil. • Verify that all sensors are installed and operating properly. Verify that all external wiring to dampers, exhaust blowers, auxiliary heaters, etc. is properly connected. • Slowly open all refrigerant service valves, and tighten the valve stem packing nuts, • Check the field and factory piping for leaks. The internal piping may have been damaged during shipping. 3.2 Airflow Balancing To ensure code compliance and long equipment service life, proper airflow must be verified by a qualified air balancer. Before you balance the airflow, locate the motor control switches located in the electrical compartment of the dehumidifier. 32 Desert Aire - SA Manual 1/5/2016 Figure 23- The Motor Control Switches are the Disconnect Terminal Blocks with knife disconnect. These are thin gray terminal blocks with an orange top that can be flipped open. Open the compressor switches to prevent the refrigeration system from running while you balance the air. 3.2.1 Airflow Setup of SelectAireTM without Integral Exhaust Fan The total airflow of a Desert Aire SA system can be checked by measuring the static pressure drop across the reheat condensers and the evaporator coils. The dehumidifier features an adjustable blower sheave to simplify air balancing. Supply Air a Outdoor Air � �4 Return Air <:1 Figure 24- Dehumidifier Side View Showing Location of Air Balance Ports (Balancing Port locations are symbolic, refer to Unit Labels for specific locations) Desert Aire - SA Manual 33 1/5/2016 3 1 2 0 Return Air <:1 Figure 24- Dehumidifier Side View Showing Location of Air Balance Ports (Balancing Port locations are symbolic, refer to Unit Labels for specific locations) Desert Aire - SA Manual 33 1/5/2016 Procedure: 1. Check the condition of the return air and outdoor air filters. They should be relatively clean during the setup procedure. If in doubt, a measured pressure drop should be taken. Expected pressure drop is less than 0.5" WC for return air filters and 0.3" WC for outdoor air filters. 2. On the display, go to SERVICE MENU r -J AIRFLOW SETTINGS +-J AIRFLOW SETUP +--I SUPPLYAIRFLOW SETUP. Set the Unocc Override to "On". 3. Confirm outdoor air damper is closed. 4. Use a manometer or magnehelic pressure gauge to measure the static air pressure differential across the reheat condenser (ports #2 and #3 above). 5. Compare the actual value read with the value displayed for reheat coil pressure drop in the Reheat dp on the controller display. If these values differ more than 0.02" WC, adjust the offset of the controller pressure differential using the SENSOR OFFSETS screen in the SERVICE MENU such that the values agree. Ensure that the manometer or magnehelic pressure gauge is properly calibrated before making any adjustment. 6. The value for Reheat dp should be the same as the Target Reheat dp +/- 0.02" WC. Should the Reheat dp be lower than the target, disconnect unit from power and adjust the sheave on the supply fan motor by turning this in and increasing the belt speed. Should the Reheat dp be higher than the target, open the adjustable sheave to decrease the belt speed. 7. On the display, press the down arrow to go to the DAMPER SETTINGS screen. Set Unit Override to "Unocc". 8. Use the manometer or magnehelic pressure gauge to measure the static pressure differential across the evaporator coil (ports #1 and #2 above). Reading should be within limits indicated on the label attached to the unit near the air balance ports. Adjust the evaporator bypass damper opening by using the control interface to adjust the "Evap" "Unocc' damper setting. This is located in the DAMPER SETTINGS menu under the SERVICE MENU. Adjusting the value to a greater percentage will open the damper and decrease the pressure differential. Adjusting the value to a lower percentage will close the damper and increase the pressure differential. Use only the controls to adjust the damper position. Do not manually limit the stroke of the damper by using mechanical stops. 9. Use a manometer or magnehelic pressure gauge to re -check the static air pressure differential across the reheat condenser (ports #2 and #3 above). Adjust the fan speed as required to achieve the indicated pressure differential. 10. Set Unit Mode to OCC. Confirm outdoor air damper opens and exhaust fan (by others) is energized. 11. Measure outdoor airflow rate with hood, duct traverse, or other measurement method appropriate for the installation. Airflow rate can be adjusted by the "OK "Occ" damper setting in the DAMPER SETTINGS menu of the controls. Note that the flow rates for outdoor air are application specific. Refer to the 34 Desert Aire - SA Manual 1/5/2016 mechanical equipment schedule or other indication from the building designer for required flow rates. 12. Use the manometer or magnehelic pressure gauge to measure the static pressure differential across the evaporator coil (ports #1 and #2 above). Reading should be within limits indicated on the label attached to the unit near the air balance ports. Adjust the evaporator bypass damper opening by using the control interface to adjust the "Evap" "Occ" damper setting. 13. Measure exhaust system air flow rate at the fans or blowers by others with hood, duct traverse, or other measurement method appropriate for the installation. Note that the flow rates for exhaust air are application specific. Refer to the mechanical equipment schedule or other indication from the building designer for required flow rates. Poolroom applications will require the exhaust air flow rate to be greater than the outdoor air to maintain a negative static pressure in the space. 14. Continue damper setup procedure for Event, Max OA, and Purge modes if the unit is equipped for any of these modes. Note that it is important to complete in this order as once Purge is initiated and then released from the override, the post -purge timed sequence that eliminates outdoor air is active. Controller power must be removed to discontinue post -purge timer early. 3.2.2 Airflow Setup of SelectAireTM with Integral Exhaust Fan The SelectAireTM systems include features to help automate the setup and operation of the unit. Afew checks need to be completed and initial limits may need to be placed into the unit controller at the time of startup. In pool applications, it is critical to maintain negative space pressurization relative to adjacent spaces and the outside ambient. This prevents moisture laden air from being driven into the wall cavities and condensing. The SelectAireTM unit includes provisions to measure the differential in static pressure between the space and the outdoors and help to maintain this negative static pressure in the space. The Desert Aire SA unit with exhaust fan contains operational controls that assist in maintaining the poolroom envelope at a negative static pressure. Proper setup allows these controls to operate as intended; however, these are not safety controls. It is the responsibility of the owner/operator to ensure that proper space pressurization of the envelope occurs. It is recommended that the pressurization be checked on a regular basis to ensure proper operation of all building systems and any issues corrected immediately. Desert Aire - SA Manual 35 1/5/2016 Supply Air a Outdoor Air a ExF 0 Figure 25 - Dehumidifier Side View Showing Direction of Airflow Supply Airflow Setup must kir a Return Air a 1. Check the condition of the return air and outdoor air filters. They should be relatively clean during the setup procedure. If in doubt, a measured pressure drop should be taken. Expected pressure drop is less than 0.5" WC for return air filters and 0.3" WC for outdoor air filters. 2. With the unit supply fan and exhaust fan disabled, check the reheat pressure drop and space static pressure readings on the controller display. Each should be indicated as 0.00 +/- 0.02. If out of tolerance, a small offset can be placed in the control under SERVICE MENU +--J SENSOR OFFSETS SCREEN. Also note that the wind direction and nearby objects can have an impact on the outdoor pressure reading. Review the installation guides for proper positioning. Review the tubing running to each location for kinks or obstructions. Review adjacent spaces for impact on poolroom pressure. 3. On the display, go to SERVICE MENU +--i AIRFLOW SETTINGS +--i AIRFLOW SETUP +--J SUPPLY AIRFLOW SETUP. Set the Unocc Override to "On". 4. The value for Reheat dp should be the same as the Target Reheat dp +/- 0.02" WC. Should the Reheat dp be lower than the target, disconnect unit from power and adjust the sheave on the supply fan motor by turning this in and increasing the belt speed. Should the Reheat dp be lower than the target, open the adjustable sheave to decrease the belt speed. Unoccupied Exhaust (Except Low Exhaust Option Equipped Units) In unoccupied mode the warm exhaust damper will index to the minimum position and the exhaust fan speed will modulate to maintain the programmed negative static pressure in the zone. The following procedure will be used to set the flow rates in unoccupied mode: 1. Use the controller display under SERVICE MENU +-J AIRFLOW SETTINGS +-J AIRFLOW SETUP +-J EXHAUSTAIRFLOW SETUP to set the Unit Mode Override to "Unocc". Set VFD to "VFD Max". Do not change the Exhaust Mode at this time. 2. There may be instances where the return air static pressure or exhaust duct static pressure is much lower than originally specified. This will increase the exhaust flow rate to a point much higher than specified. In these 36 Desert Aire - SA Manual 1/5/2016 circumstances, a warning for high current may display on the Variable Frequency Drive (VFD). Should this be the case, adjust Max Warm Exhaust value lower until warning is no longer present. 3. Set Unit Mode Override to "Auto". The exhaust fan VFD will modulate to maintain the space pressurization setpoint. 4. Review the actual space static pressure through the use of independent measurement device such as a manometer or magnehelic. This can usually be done by slipping the manometer tubing through a door leading outside. Repeat for other doors or windows to ensure the negative space pressurization is sufficient. Occupied Modes and Unoccupied with Low Exhaust Option Exhaust Desert Aire SelectAireTM units can be equipped with several different types of outdoor air and exhaust air modes of operation. A unit may be equipped with one or more of these modes of operation. Each mode will include a separate specification for outdoor air flow rate that is specified at the time of order. These modes may include: • Unoccupied Mode (When Equipped with Low Exhaust Option) • Occupied Mode • Event Mode • Max. OA Mode The unit shall be balanced with the highest outdoor air flow rate with the following steps: 1. Use the controller display under SERVICE MENU +-J AIRFLOW SETTINGS AIRFLOW SETUP +J EXHAUSTAIRFLOW SETUP to set the Set Unit Override to "Occ". Set Exhaust Mode to "Cool'. Set VFD to "VFD Max". 2. Unit will open the Cool Air Exhaust Damper downstream of the evaporator coil. Unit specified with high amounts of outdoor air may also open the exhaust damper upstream of the coil in this mode. The exhaust fan speed command will increase to maximum. 3. Should the motor current be higher than design due to low static pressure, a warning for high current will be displayed on the VFD and the frequency will be automatically limited to a lesser value. If the warning is being displayed, adjust VFD Max % lower until the warning is no longer displayed. 4. There may be instances where the space requires additional fan speed to achieve negative static pressure in the zone. The Max Fan Speed Output Setting can be increased. If the high current warning is displayed on the VFD, the physical limitations of the system have been reached. 5. Set Exhaust Mode to "Warm". 6. Should there be a lower than specified return air static pressure or exhaust duct static pressure, a high current condition may be displayed on the VFD and the frequency will be automatically limited to a lesser value. Should this be the case, adjust Max Warm Exhaust value lower until warning is no longer present. Desert Aire - SA Manual 37 1/5/2016 Purge Mode Unit equipped with Purge Mode have the capability for a very high flow rate of outdoor air and exhaust airflow. During Purge Mode the compressors are disabled and heating is shifted to an alternate minimum supply air temperature control to prevent condensation without unnecessary conditioning air to be exhausted. Only the warm exhaust damper will open during the Purge Mode of operation. The unit shall be balanced in Purge Mode with the following steps: 1. Set Unit Override to "Purge". 2. Set Exhaust Mode to "Auto". 3. Set VFD to "VFD Max". 4. A high current condition may be displayed on the VFD and the frequency will be automatically limited to a lesser value. Should this be the case, adjust Max Warm Exhaust value lower until the warning is no longer present. Record the final set points on the Start -Up Report. It should be noted that filter changes are important to ensuring that exhaust air and outdoor air are able to be maintained at the proper flow rates. The SelectAireTI system operation will automatically adjust to accommodate normal increases in static pressure drop, but excessive filter loading will restrict airflow. Filters should be monitored and replaced as required. Evaporator Settings and Cool Exhaust Airflow There may be additional display screens for the evaporator and cool exhaust airflow. The values are preset from the factory and optimized. No adjustment is required unless instructed by Desert Aire Service. 3.2.3 Final Air Balancing Once the supply air and exhaust air setup have occurred, the unit will automatically adjust the damper positions and drive speed in each mode of operation. The outdoor air damper will open and modulate to achieve the pre -determined pressure drop set point of the outdoor air stream pressure plate. This has been determined by the customer requested occupied mode flow rate and tested at the factory. The exhaust will be controlled by space pressurization and maintains the negative static pressure set point. This is also a good opportunity to ensure that the commands for operational modes are being properly sent to the equipment. Command each mode of operation through the method that will be used on site. Depending on the mode and installation specific, this may occur through the internal time schedule, a contact closure, or the Building Management System. 38 Desert Aire - SA Manual 1/5/2016 In unoccupied mode, check and record the following: • Return duct static pressure to atmosphere • Supply air flow rate and static pressure to atmosphere • Supply fan motor current In each outdoor air mode of operation, check and record the following: • Exhaust air flow rate and static pressure due to atmosphere (indoor units) • Outdoor air flow rate and static pressure to atmosphere (indoor units) • Exhaust fan motor current (use True RMS meter only on VFD drives) • Space pressure relative to outdoors and adjacent spaces Note that once Purge is initiated and then released from the override, the post -purge timed sequence that eliminates outdoor air is active. Controller power must be removed to discontinue post -purge timer early. Should the requirements for outdoor air in an application change or the readings of pressure sensors are affected by the installation, the settings can be changed for each mode under SERVICE MENU +-J AIRFLOW SETTINGS N AIRFLOW SETUP scrolling down will show the set points the unit is controlling for each OA mode of operation. Always ensure that the zone is negative relative to adjacent spaces should this be changed. The Desert Aire SA unit with exhaust fan contains operational controls that assist in maintaining the poolroom envelope at a negative static pressure. Proper setup allows these controls to operate as intended; however, these are not safety controls. It is the responsibility of the owner/operator to ensure that proper space pressurization of the envelope occurs. It is recommended that the pressurization be checked on a regular basis to ensure proper operation of all building systems and any issues corrected immediately. Auxiliary Heating Ensure that the supply air temperature sensor is downstream of any field installed auxiliary heaters. The pre-programmed values for the deadbands, differentials, and PID values are expected to create a good balance between temperature control and stability in the typical applications. Occasionally the heater may have larger or smaller capacity relative to the space or sensor placement may be in an atypical location. If space conditions vary greatly or frequent cycling between modes are apparent, the values Desert Aire - SA Manual 39 1/5/2016 may need to be changed. Modification to the parameters and tuning should be done with care. If it is determined that a specific application would benefit from modification, time and patience will be required to ensure that the desired effect is achieve. Staged Heating When installed in a relatively mild climate with minimal outdoor air requirements, there is a relatively small amount of heating capacity. In these cases, staged heating is a cost effective and simple method. The auxiliary heating outputs come set from the factory for control of staged control or modulating control as specified at the time of order. When set for Staged, the dry contact associated with the heating output will close on a drop in temperature of the zone set point minus the deadband minus the differential. The contact will remain closed until the temperature reaches the zone set point minus the differential. Heater On = Zone Setpoint — Heating Deadband — Heating Differential Heater Off = Zone Setpoint — Heating Deadband Example: - Zone Setpoint: 85°F - Heating Deadband: 2°F - Heating Differential: 1°F In this example, the heater output will close at 82°F and will open at 83°F. Due to some system capacitance and sensor hysteresis, the actual zone condition may overshoot these values slightly, but should not overshoot these values to cause the unit to shift into a cooling mode. Should the heater be very oversized and the overshoot significant, it may be necessary to increase the deadband to prevent cycling between modes. It should be noted that the nature of the staged heating will create a significant variation in the supply air temperature as the heater is turned on and off. Heaters are sized for extreme conditions (typically the 99th percentile heating capacity). At many times of the year the heater is essentially oversized. Depending on the location of the supply ducts and diffuser configurations, the variations may create drafts within the space. Also, if the air temperature is very low and the heater cycles off, the supply air temperature may be lower than the space dew point. This would cause condensation on ducts, diffusers, and surfaces. Should there be issues with supply temperature variations, modulating heat should be considered. 40 Desert Aire - SA Manual 1/5/2016 Modulating Heating When the application has a moderate to extreme climate and outdoor air is specified, it is recommended that auxiliary heating be modulating. When the controls are set for Modulating heat output, both the binary heat output contact and the modulating heat output are active. The binary heat output acts as an enable contact that can activate a gas heater enable signal or start a hot water coil pump system. The modulating output is intended to vary the gas valve, SCR electric heater, or hot water coil water flow rate. The Modulating heating sequence works based on a Zone Reset of the Supply Air Temperature. When the zone temperature decreases to the Zone Temperature minus the Heating Deadband, the controller enables heating mode and starts to increase the calculated Supply Air Temperature Set Point. The heater output will modulate to maintain the calculated Supply Air Temperature Set Point. The heating mode is always disabled if the zone exceeds the Zone Temperature Set Point. Resetting the supply air temperature in heating not only closely maintains the zone temperatures, but helps ensure the supply air temperature is held to minimum values. The default values used for the zone PID, supply air PID, and deadband are appropriate for most applications and heater sizes. Should the commanded Supply Air Temperature change too quickly, the PID action for the reset can be slowed by increasing the tuning values. Should the heater not be able to closely maintain the calculated Supply Air Temperature Set Point, the values for the heater output loop can be adjusted. Heater Enabled = Zone = Zone Setpoint — Heating Deadband Heater Disabled = Heat Output PID Loop < 5% or Zone = Zone Set Point Example: - Zone Setpoint: 85°F - Heating Deadband: 2°F In this example, the binary heater contact will close at 83°F and the analog output will start to increase. The PID loop will modulate to maintain the zone at the 83°F temperature. Should the analog signal for heat decrease to less than 5%, the binary contact will open. In addition, if the zone is sensed at greater than 85°F at any point, the contact will open, limiting heater overshoot due to poorly tuned loop. Final Review of the Unit Operation Under typical circumstances, the unit will cycle into and out of a mode of operation over a period of time. This will typically continue until the environmental conditions change or another outside influence causes the load to differ. The duration of each cycle will depend on the unit capacity and the activity within the space as well as the Desert Aire - SA Manual 41 1/5/2016 building construction, set point, and ambient conditions. The controller is programmed with minimum mode times that prevent short compressor cycles and quick indexing of modes. This minimum mode time is set at 360 seconds as a default. When the loads are very low and the unit is relatively large for the application, this may cause a slight overshoot in space condition for cooling and dehumidification. Frequent cycling between heating and cooling is not expected, however. It is recommended that as a final check that the unit be released from all overrides, offsets, and returned to the expected set points. Observation of the typical operation under load is an invaluable tool in ensuring that all aspects of the system are working as anticipated. Observing the unit control the space for a few cycles is recommended. This can be done reasonably well as the tools and site is being cleaned up at the end of a startup or service call. The following are examples of how the unit will be expected to operate in the typical loads encountered. Note that there are many variables in conditions and unit sizing. These are included to give basic understanding of the expected operation. Ambient Condition Cool and Humid (Typical Spring Day) Unit will be primarily in dehumidification mode and may cycle in 1 st and 2nd stages of dehumidification. The hot gas reheat coil will be active most times. The unit may occasionally shift to cooling mode on one or both circuits, especially during mid-day when the solar load is high. During the night-time hours when the unit is unoccupied and ambient starts to cool, the unit will be in dehumidification mode less frequently and auxiliary heating may become active. Ambient Condition Hot and Humid (Typical Summer Day) Unit will be primarily in dehumidification mode and cooling active. The remote condenser will be active most times. The unit may occasionally shift to dehumidification mode on one circuit, especially as the solar load starts to decrease in the afternoon. During the night-time hours when the unit is unoccupied and ambient starts to cool, the unit will be in cooling mode less frequently and more frequently in dehumidification. Ambient Condition Hot and Dry (Typical Early Fall Day) Unit will be primarily in cooling mode with one or two circuits active. Depending on the load one or both of the circuits may cycle on and off to maintain condition. During the night-time hours when the unit is unoccupied and ambient starts to cool, the unit will be in cooling mode less frequently and auxiliary heating may become active. 42 Desert Aire - SA Manual 1/5/2016 Ambient Condition Cold and Dry (Typical Winter Day) If the unit is equipped with exhaust energy recovery, and the controller senses the zone is dehumidified and temperature within the space is dropping, it will shift to energy recovery mode. This will energize the Circuit A compressor(s) and open the cool exhaust damper. This uses the refrigeration as a heat -pump to recover the energy in the exhaust air. This energy recovery can be considered the first stage of heating and will occur before the auxiliary heating is activated. During the daytime the unit may occasionally be in dehumidification mode. Energy recovery will index on as required and auxiliary heating will become active as required to maintain space conditions. Note that it is not uncommon for the unit to occasionally shift into cooling mode in the wintertime when the solar load is high and the envelope contains high number of south facing windows. This can occur down to 30°F or even lower in some cases. Note, that in extreme cool and dry conditions when in occupied mode the outdoor air may dry the space significantly. When this is the case, the exhaust air may no longer have the energy to recover. The unit controls will disable the energy recovery mode when this occurs if the unit is equipped with the option. 3.3 Refrigeration Testing Refrigerant based cooling systems are sometimes referred to as "sealed systems". This is in reference to the refrigeration system being hermetically sealed, no refrigerant can leave the system and no contaminants are allowed inside. Factory equipment and procedures ensure a clean and tight refrigeration system where only the specified refrigerant and oil are in the system. This is a critical component to the longevity of the system. Some Desert Aire systems are shipped in sections to allow for installation of some of the sections in a location much different than another. An example is a unit with a remote condenser ready circuit. The dehumidifier may be installed indoors near the conditioned space while the remote condenser used to reject waste heat is located outdoors. The piping of the condenser is completed in the field before the unit is commissioned. The design and processing of the field piping is just as important as the factory piping in ensuring the longevity of the system. Selection of quality components, quality procedures, and full testing help to ensure that sealed system failures are minimized wherever possible. Nonetheless, the mechanical nature of many components creates some unforeseen wear and failure in certain instances. Some units may need service at a point in the life of the product that requires opening of the hermetic refrigeration system. Special care must be taken to ensure that the system is returned to service without contamination. Desert Aire - SA Manual 43 1/5/2016 Whenever servicing Desert Aire equipment, observe the following: • Use only equipment rated for the pressures of the refrigerant being serviced. • Use only equipment dedicated to service of the refrigerant in the system. Do not use equipment to service multiple refrigerant types. • Purge all hoses and equipment of non -condensable gasses before connecting to the sealed system. • Use only original equipment parts or factory approved equivalent for servicing. • Use required refrigeration system oil. • Minimize the time the system is open to atmosphere while servicing. Cap all connections where there is no active service work on the system. This is particularly important with units that contain POE oils as moisture will be absorbed quickly and cannot be removed with a vacuum. • Never open the system while under a vacuum. Should system require opening to repair a leak or other service when a vacuum, fill with dry nitrogen to atmospheric pressure before opening. • Have a Schrader core replacement tool available when servicing the refrigeration system. Although rare, defective or damaged Schrader valve cores can contribute to refrigerant loss. • Charge system only by weight after servicing. Review the rating plate and any field charge labels. • When servicing, additional liquid line filter dryers and suction filters may be required. This does not apply to installation of remote condensers. • Charge refrigerant blends, including R-41 OA and R -407C, with liquid only. Charging should be done into the high side of the system wherever possible. Refer to Section 5.6 for additional procedures related to charging. Note that superheat should be stable within 7 degrees. The temperature and relative humidity listed in Figure 26 is the Return Air. Minimum value for superheat at compressor in all modes: � L . Superheat Minimum Values Chart Temp (°F) Relative Air Temperature (°F) 60.0 - 65.0 65.1 - 70.0 70.1 - 75.0 75.1 - 80.0 80.1 - 85.0 85.1 - 90.0 30.0-40.0 12 13 14 15 15 16 Q 40.1 -50.0 13 14 15 15 16 18 76� 50.1 -60.0 13 14 15 16 18 18 60.1 -70.0 14 15 15 16 18 19 = 70.1 - 80.0 14 15 16 18 19 20 Figure 26 - Superheat Minimum Values Chart 44 Desert Aire - SA Manual 1/5/2016 3.4 General Testing After you balance the airflow and test the refrigeration circuits, verify that the other equipment and accessories connected to the dehumidifier work properly. Although this may be difficult, since the dehumidifier is usually interlocked with a variety of equipment installed by different contractors, you must not skip this step. Each of these devices (which may include auxiliary air and water heaters, smoke alarms, circulating pumps, and a building management system) is vital in maintaining the performance and comfort of the swimming pool environment. Many customer complaints are caused by improper interlocks between these devices. Make sure you check the following: • Check the outdoor air and exhaust devices. The outdoor air and exhaust dampers must open when they receive an "occupied" signal from the dehumidifier. If you have installed an exhaust blower, make sure that it is interlocked with the "occupied" signal or with an end switch on the outdoor air damper actuator. • Check the condensate drain to make sure it has been trapped and primed with water. Verify that it drains freely, with no leaks. If the drain is outside or in an unconditioned space, make sure it has been heat traced. If you installed a condensate pump, make sure it operates properly. • Check the pool water piping to the dehumidifier (on units equipped with optional pool water heating). Make sure that all air has been bled out of the lines, and check that an air bleed valve has been installed at any high points in the water lines. if the circulating pump is not set for continuous operation, make sure it is properly interlocked with the dehumidifier. Temporarily shut off the water flow to the unit to verify that the factory -installed water flow proving switch operates correctly. Verify that the pool water temperature sensor has been installed where water will flow over it continuously. Verify that the pool water temperature sensor is on the water inlet of the unit. • Check the operation of the remote condenser (on units equipped with this option). Make sure that the pressure transducers are wired to the condenser fan cycling control, the cut -in and cut-out pressures are correctly set per the remote condenser installation manual. Verify that the fans are blowing vertically upward when they run. • Check the temperature and humidity readings displayed on the controller. If you think the values are incorrect, check the sensor or its field -installed wiring for damage. If necessary, check the voltage jumper on the temperature and humidity sensor. It must be set in the "0-10 VDC" position. 3.5 Routine Maintenance Schedule 3.5.1 Service Every Month • Check and replace the air filters in the return duct and the outdoor air duct. • Check for dirty coils in the dehumidifier. Clean them if necessary. Desert Aire - SA Manual 45 1/5/2016 3.5.2 Service Every Six Months • Check the blower belts for wear or glazing. Tighten or replace them if necessary. Do not use belt dressing compound. • Check and tighten all field and factory electrical connections. • Check for dirty coils in the dehumidifier and the optional remote condenser. • Check and clean the drain pans and blow out the condensate drain line. If the drain is plugged, water will back up into the dehumidifier and flood the mechanical room. • Check and adjust the air flow per specifications. Dirty ducts, filters, and coils may have reduced the total air volume. • Check the operating pressures of the refrigeration circuits. • Check the current draw of each blower motor. • Check the current draw of each compressor. • Lubricate the blower motor(s). • Lubricate the supply blower bearings. NOTE: please have the following information available if you need to call the Desert Aire Service Department: • Model Number • Serial Number • Room Temperature • Relative Humidity • Operating Refrigeration Pressures • Water Temperature • Compressor Amperages • Blower Motor Amperage(s) 46 Desert Aire - SA Manual 1/5/2016 4. Troubleshooting Although Desert Aire dehumidifiers have been designed for reliable and trouble-free operation, you may occasionally encounter a service -related problem. If you cannot immediately diagnose a fix to the problems, do not be intimidated by the apparent complexity of the dehumidifier. Your common sense and experience can help you solve the majority of these problems. These problems or complaints are frequently caused by improper interlocks between the dehumidifier and the other equipment and accessories at the jobsite. You may need to consult with other contractors who have worked on different portions of this project. Read Section 3.4 for a more detailed list of interlocks. The following list will help you diagnose some of the most obvious symptoms of a system which does not work properly. 4.1 The Blower Does Not Run The standard Desert Aire dehumidifier is designed for continuous blower operation, which helps prevent air stratification, occupant discomfort, and structural damage to the ceiling and upper walls of the poolroom. Check for these problems: • Check for power at the power block on the electrical panel of the dehumidifier. • Verify that the incoming power matches the value printed on the unit rating plate. • Check the branch fusing. Replace any defective fuses and determine why they failed. • Use a voltmeter to trace the low -voltage control wiring. Determine if voltage is applied to the holding coil of the blower contactor. • If there is no voltage at the holding coil, check the blower overload, the control transformer, the smoke alarm interlock, or the optional voltage monitor relay. • if the dehumidifier uses a non-standard controller, or if the blower is cycled by the building management system, consult with the controls contractor. 4.2 The Compressor(s) Do Not Run If a compressor doesn't run even though the humidity in the poolroom is excessive, check the sequence of operation of the dehumidifier. Under certain situations the controller will lock out the compressors to prevent the pool room from overheating. See Section 5.5 in the Appendix for more details. If the problem is not controller -related, check the following: • Check the "Compressor Fault" indicator on the controller display panel (for dehumidifiers with the standard controller). The fault indicator will flash if one of the compressor safety devices has tripped. The indicator will automatically stop flashing when the problem has been corrected. See the low -voltage wiring schematic for details on this fault circuit. • Check for power at the power block on the electrical panel of the dehumidifier. • Verify that the incoming power matches the value printed on the unit rating plate. • Use a voltmeter to trace the low -voltage control wiring. Determine if voltage is applied to the holding coil of the compressor contactor. • If there is no voltage at the holding coil, check the compressor overload and safety devices, the Desert Aire - SA Manual 47 1/5/2016 control transformer, the smoke alarm interlock, the airflow proving switch, or the optional voltage monitor relay. • If the dehumidifier uses a non-standard controller, or if the compressors are cycled by the building management system, consult with the controls contractor. • Confirm that the compressor "knife" switches from air balancing section have been closed. 4.3 High Pressure Alarms/Readings Above 575 PSIG The unit contains a pressure transducer and control sequence that will interrupt power to the compressor if the refrigeration system pressure is excessively high. The alarm will be active on the local display and the building management system (if equipped). The alarm can be reset at the main alarm screen on the display. • Check that all service valves and ball valves in the compressor discharge line are fully open. • Verify that the reheat condenser is clean and free from debris. Use a Magnehelice or an inclined manometer to check the air volume through the reheat condenser. See Section 3.2 for more detailed instructions. • Check that there is adequate water flowing through the pool water condenser (on units equipped with this option). Verify the operation of the water flow switch. • Check the remote condenser fuses, fan motors, and fan cycling switches (on units equipped with this option). Verify that the fans are not obstructed and that they blow the air vertically upward. • Check the three-way heat reclaim valve for proper operation. This valve, which is installed in the compressor discharge line, diverts hot refrigerant vapor to the various condensers (on units equipped with optional pool water heating or remote condensers). The valve spool may be stuck in the middle of the valve, where it blocks the outlets to both condensers. You can verify its operation by first running the compressor and then measuring the temperature of both condenser outlets. If the valve is shifting normally, the active condenser outlet will heat up rapidly. • Check for air or other non-condensables in the refrigeration circuit. Desert Aire installs purge ports in the highest point of each condenser's discharge line. To purge these gases from the system, temporarily run the compressor while you energize the selected condenser. Shut the compressor off, but continue to circulate cooling air or water through the condenser. Slowly depress the Schrader core at the high point purge of the condenser. You can do this procedure to keep the system running, but it is a temporary fix. It is not a longterm substitute for proper evacuation with a vacuum pump. • If the dehumidifier uses an outdoor air duct with a field -installed preheating coil, verify that the coil is only active during the heating season. • If the system is overcharged or excessively cold, migrating refrigerant can liquefy and fill a condenser and its discharge line during the "off -cycle". If the compressor starts and the three-way valve shifts to this flooded condenser, the high pressure switch will trip almost immediately. Remote outdoor condensers are particularly susceptible to this problem during the winter months. 4.4 Low Pressure Alarms/Evaporator Coil Icing The unit contains a pressure transducer and control sequence that will interrupt power to the compressor if the refrigeration system pressure is excessively low. The alarm will be active on the local 48 Desert Aire - SA Manual 1/5/2016 display and the building management system (if equipped). In this active alarm state, the circuit will stop and not restart until the Suction Pressure in that circuit rises 48 psi above the Low Suction Pressure Trip Set Point. Although the circuit will restart automatically, the red ALARM LED on the display will stay lit until the alarm is acknowledged, even after the alarm condition is cleared, to alert the operator the alarm occurred. The alarm can be reset at the main alarm screen on the display. • Check the return air ductwork. Poorly designed, restrictive ductwork can cause stratification or faulty air distribution. Resize the return air ductwork and grilles, or add turning vanes if necessary. • Verify that the evaporator and return air filters are clean and free from debris. Use a Magnehelic® or an inclined manometer to check the air volume through the evaporator coils. See Section 3.2 for more detailed instructions. • Check the temperature and humidity of the return air. The SA evaporators are designed for maximum efficiency at typical swimming pool conditions. If the return air wet bulb temperature drops below 60°F, these coils may frost. Never introduce unconditioned outdoor air into the return duct of an SA series dehumidifier! • Check that all service valves and solenoid valves in the liquid line are energized or fully open. • Verify that there are no restrictions or debris in the liquid line solenoid, the filter/drier, the expansion valve, or the distributor. • Check to see that the system is properly charged and that the liquid line sight glass shows no bubbles. The refrigerant on an undercharged system can migrate to the coldest condenser on the "off cycle", causing the receiver to lose its liquid seal. 4.5 The Pool Water Is Too Cold This section applies to Desert Aire dehumidifiers with the pool water heating option. If the pool water requires heating, the standard controller will command the dehumidifier to heat the water. If the dehumidifier cannot heat the pool, due to inadequate water flow or no demand for dehumidification, the water temperature will drop slightly. The controller will then energize the auxiliary water heater, if one has been installed. See Section 5.5 in the Appendix for more details. If the problem is not controller -related, check the following: • Make sure that the refrigeration circuit containing the pool water condenser has not locked out on a safety trip. • Check the "Pool Water Flow" indicator on the controller display panel (for dehumidifiers with the standard controller). The fault indicator will flash if the water flow proving switch does not sense water flow. When this happens, the dehumidifier will not run in the pool water heating mode. All other modes will operate normally. The fault indicator will automatically stop flashing when the problem has been corrected. • Temporarily raise the pool water heating set point to verify that the auxiliary pool heater energizes on call for second stage pool heat. • If an auxiliary pool heater has not been installed, remove the "air/water priority" jumper from the electrical panel of the dehumidifier. See the wiring schematics and Section 5.5 in the Appendix for details. • Make sure that the water filters are not clogged. • Verify that the water condenser and pool water lines are free of fouling and scaling. • Check that all service valves and solenoid valves in the liquid line are energized or fully open. Desert Aire - SA Manual 49 1/5/2016 Verify that there are no restrictions or debris in the liquid line solenoid, the filter/drier, the expansion valve, or the distributor. 50 Desert Aire - SA Manual 1/5/2016 5. Appendix 5.1 Compressor Failure Although some compressors fail because they are mechanically flawed, most failures are due to system -related problems. Compressor failure can be caused by liquid flood back, air or moisture in the refrigerant system, solid contaminants, excessive heat or electrical service malfunctions. To avoid repeated callbacks, you must determine the cause of the failure and then correct it. If the compressor has failed because its motor has burned out, the refrigerant oil, and piping may have become severely contaminated. If a burnout has occurred, use the following procedure to replace the compressor and clean the refrigerant system. Use an oil test kit to determine the severity of the burnout. Make sure you use rubber gloves and eye protection, as contaminated refrigerant and oil can cause severe burns! You must clean the system thoroughly to prevent repeated compressor burnouts. 5.1.1 Compressor Replacement Desert Aire dehumidifiers are designed with scroll compressors. Scroll compressors are known for operating more reliably than other compressors in air conditioning and dehumidification applications due to their ability to cope with occasional periods of liquid refrigerant return. There are fewer moving parts in a scroll compressor subject to wear compared to alternative compressor designs. Nonetheless, there are still many mechanical and electrical parts with close tolerances. Replacement of the compressor may be required during the normal service life of the dehumidifier. Inspection and Initial Diagnosis Generally, the compressor will have two basic failure modes, mechanical and electrical. The compressors are a hermetic design, meaning all components, including the motor, are in a sealed shell. It can be very difficult to determine which issue was the root cause of the failure in the field by inspection of the damaged compressor. For example, an initial bearing failure inside the compressor may create debris that contaminates motor windings. High current draw may be related to a bearing issue or a motor winding issue. The initial inspection must be combined with a final analysis of the machine when returned to working order to confirm diagnosis. Specific items should be noted before the replacement to give the best indications of the failure and complete the diagnosis as the new compressor is installed. The following data should be taken to assist in diagnosis: • Current draw for each leg of power (if the compressor will run and pump) • High side and low side pressure (if the compressor will run and pump) • Resistance of each leg to leg on three phase compressor or each leg to neutral on single phase compressors. Desert Aire - SA Manual 51 1/5/2016 • Check of continuity from each leg to ground. • Review of all system alarms including the relative timing of the alarms and mode of operation. It is important to note that other components or lines may have been damaged if the compressor has failed. At times the internal damage to a compressor creates extreme levels of vibration before complete failure. Refrigerant lines and connections may be damaged before the compressor stops. Inspect tubing and components of the system before completing the compressor replacement. Compressor Replacement • Refrigeration oil must be tested for acid and particulate during any compressor replacement. For the initial testing, the compressor sump should be used to sample the oil. Oil can be recovered through the Schrader port on the low point compressor shell or through the suction line connection after the compressor has been removed. • Use Virginia KMP, New -Calgon Phase III, Sporlan Test -All, or equivalent oil test where oil is sampled into a container. Vapor sampling methods may not show particulate and should not be used. • Read the oil test kit manufacturer's instructions to determine if there is acid present in the oil. Determine if there are other contaminants by viewing the samples for darkness, cloudiness, or particulate. The following procedures must be used depending on the results of the test above: Any Compressor Service • A new filter dryer must be installed when the system has been opened. See Section 5.6 for component replacements. If there is no acid or particulates indicated, the new compressor can be installed and run. Proceed to Testing and Final Diagnosis. Acid Indicated • Install a suction line filter shell and charcoal activated core such as a Sporlan or Emerson HH core type or equivalent. The acid levels will be monitored and several core changes may be required. Install ball valves on either side of the suction filter to facilitate these changes. Note that larger Desert Aire systems will have suction filter shells installed from the factory. The shell can be used with charcoal activated cores. Note that a "safety screen" may be required with some manufacturer's cores to prevent small pieces of the core from dislodging and finding their way to the compressor. Follow filter shell and core manufacturer's instructions. • Review compressor and suction line for an area where future oil samples can be taken from the system. If an access fitting exists on the compressor shell below the oil level, no further action is needed. If this is not available, an access fitting can be located at the bottom of a trap in the suction line. Braze in a fitting as required to be able to remove an oil sample. • Ensure there are access fittings directly upstream and downstream of the suction filter. There is typically one fitting installed on the suction filter. There may be a bulkhead fitting attached to the compressor suction side. 52 Desert Aire - SA Manual 1/5/2016 Do not use acid neutralizing additives or other chemicals for acid removal. The refrigeration system must contain only oil and refrigerant. Precipitates of additives and acids may be considered contamination in the refrigeration system. Other compounds may be present in additives as carriers. Longterm effects of specific additives or compounds with a particular system or design are unknown without significant controlled testing. Particulate Indicated • Install a replaceable core liquid line filter shell. Note that larger Desert Aire systems will have replaceable core liquid line filter shells installed from the factory. The pressure drop levels will be monitored and several core changes may be required. Install ball valves on either side of the filter shell to facilitate these changes. • Install a secondary filter such as Sporlan FS -series or equivalent 20 micron filter in the replaceable core. Ensure there are access fittings directly upstream and downstream of the liquid filter. There is typically one fitting installed on the filter shell. There is typically one fitting installed on the outlet side of the receiver. Returning to Service • See Section 5.6 for evacuation and charging. • Restart unit and set unit to run compressors. • Record the pressure drop across the suction filter and liquid line filter dryer. • Check sight -glass indicator for moisture level. • Monitor pressure drop across the liquid and suction filters during the first hour of operation. Compare the reading taken earlier. If the pressure differential across the filters is more than 5 PSI greater than the initial reading, isolate the filters using the valves installed and recover the refrigerant from the filters. Replace cores. If activated carbon filters were installed in the suction side to remove acid, replace with similar cores. If a secondary filter was installed in the liquid line core to remove particulate, install cores and secondary filter in this location. • Run unit for 24 hours and review acid levels (if found previously) and pressure differentials. - If acid is found, replace with activated charcoal cores and test at 24 hour intervals until acids are at acceptable levels. Once acid is no longer detected, replace cores with standard filter elements. Remove outlet screens if they were required by filter manufacturer. If the pressure differential across the liquid line filter is more than 5 PSI greater than the initial reading, replace cores and secondary filter with new components and test at 24 hour intervals until pressure drop is at acceptable levels. Once pressure differential is less than 5 PSI, remove secondary filter and replace cores. Testing and Final Diagnosis It is of critical importance to ensure that the system is operating as expected before unit is returned to normal service. Complete a Compressor Replacement Form located in the Installation and Operation Manual. Validation of this report allows for the continued coverage of the compressor under the original warranty. Desert Aire - SA Manual 53 1/5/2016 5.2 It is possible that there was an internal defect in the compressor or normal mechanical wear occurred over time. Compressors longevity generally is a function of load, lubrication, electrical input conditions, and temperatures. There is a cause for the compressor failures that must be identified before unit is placed back into full service. Both the identification of the cause of compressor failure and the proper cleanup of the system must be addressed to avoid repeat compressor damage. Recommended Duct Design You must use proper duct design to ensure that the dehumidifier operates efficiently and without problems. Undersized or restrictive ducts reduce the system airflow, which can cause premature compressor failure. Use the following diagrams as a guide when you design the duct system. Recommended 20° or Less Discharge Duct Turns Desert Aire W �1-1 5W or More For Static Pressure Regain Intake 1 Duct Turns L� W Desert Aire 2.5W or More Intake Duct Turns Desert Aire L 54 Desert Aire - SA Manual Not Recommended 30° or More Discharge 1 Desert Aire Intake Desert Aire Intake Desert Aire Figure 27 - Recommended Duct Designs for Desert Aire Dehumidifiers 1/5/2016 5.3 Pool Water Chemistry Pool chemistry must be maintained to ensure the proper pH, total alkalinity, calcium hardness, and free chlorine. NSPI recommends the following levels for pool chemistry: • pH: 7.4-7.6 • Total Alkalinity: 100 — 150 ppm • Calcium Hardness: 200 — 250 ppm (Plaster Pool) • Free Chlorine: 1.0 — 3.0 ppm Excessive chemical levels in the pool can be dangerous to users and can damage pool hardware, including the dehumidification system. The Desert Aire warranty does not cover equipment damaged by faulty pool chemistry. 5.4 Recommended Controller Settings 5.4.1 Controller Set Points It is important to determine your comfortable set points and to avoid further controller adjustments. It takes time for the unit to establish equilibrium at a given set point. Therefore, continued set point adjustments will lead to high energy consumption and user discomfort. Continuous blower operation is recommended. This will reduce air stratification and assure that the refrigeration circuit is activated only when it is necessary. RECOMMENDED SET POINTS: Humidity: 50% to 60 % RH Air Temperature: 2° to 4° F above the pool water temperature Never disable a dehumidifier in a pool room application unless the pool has been drained. Even when not in use, pool water continues to evaporate adding moisture to the air. During these periods of high humidity, moisture will seep into walls, ceilings, furniture, etc. Although the dehumidifier may be capable of regaining control of pool room conditions after re -start, in the long run, moisture damage to the pool room will become apparent. 5.5 System Operating Modes The standard sequence of operation of a Desert Aire dehumidifier is relatively simple to understand. Note that the sequence may vary depending on which condenser options have been purchased and installed. The compressor is designed to start on a call for dehumidification. As the refrigerant flows through the evaporator, it absorbs a great deal of heat from the airstream. This heat can either be rejected to the Desert Aire - SA Manual 55 1/5/2016 air or to the pool, depending on which needs to be heated. • If neither the air nor the water needs heat, it will be rejected to the remote outdoor condenser. • If no outdoor condenser is available, the compressor will shut off rather than overheat the room air. Although the system cannot dehumidify the air when its compressor is off, overheating the space is unacceptable because it will cause occupant discomfort. • For this same reason, the compressor can start and run on a call for air cooling if another heat sink is available. 5.6 Component Replacement, Charge, Evacuation, & Leak Instructions Note that a new liquid line filter dryer will be required any time a refrigeration system is opened for servicing. New dryer should be of the same capacity as the original or larger. Recovery When there has not been a major refrigeration system leak, the system will contain refrigerant. This refrigerant must be either recovered to separate cylinders appropriate for the refrigerant type of isolated in a portion of the refrigeration system that will not be open for service. In all cases you must comply with Section 608 Refrigerant Recycling Rule of the Clean Air Act. Recovery of Systems with a Refrigeration System Leak As much refrigerant as possible must be recovered into separate refrigerant cylinders appropriate for the refrigerant being serviced. System pressure near the leak site should be monitored closely to ensure this area is not pulled to a vacuum. Isolate sections of the system as required and recover independently to avoid refrigerant contamination. Uncontaminated refrigerant can be reused in the refrigeration system it was recovered from. Recovery of Systems without a Leak Systems that do not have leaks, but still require refrigeration system service, may have charge isolated in receivers and condensers if these particular components do not require direct service. Desert Aire dehumidifiers have different receiver sizes depending on the model and size. Condenser sizes and configurations may also vary. In general, larger receivers will come equipped with isolation valves that will allow for a portion of the charge to be contained in the receiver during servicing. Units equipped with remote condensers will have isolation valves located inside the unit cabinet near the area where the connections are made. The compressor can be used to move refrigerant to the system components that will be used to temporarily hold the charge. Note that cooling a condenser by running as many fans as possible and/or cooling the coil surface with a stream of water can assist in storing charge. The low side pressure should be monitored closely while using this procedure to store charge. Under no circumstances should a compressor be allowed to run in a vacuum. When most of the refrigerant is 56 Desert Aire - SA Manual 1/5/2016 isolated in the receiver and/or condensers, recover remaining charge into separate refrigerant cylinders appropriate for the refrigerant being serviced. Carefully track the amount of refrigerant charge removed as this exact amount should be placed into the units when re -charging. Repair / Component Replacement • If any portion of the system was at a vacuum, place dry nitrogen in the system until atmospheric pressure is reached. • It is preferred that components are removed by heating the braze alloy to the remelt temperature and mechanically moving the component. When this is not possible due to proximity of cabinet structure or other components, a tubing cutter can be used to remove sections of piping. Where new tube is required for replacement, use dehydrated tube where possible. Use the same type of fittings as original. Route the pipe in the exact manner as originally routed. • Use Type K per ASTM B 88 or ASTM 8819 or Type ACR per ASTM B 280 copper tubing or for all tubes 1-1/8" and smaller. • Tubes 1-3/8" and larger shall use Type K per ASTM B88 or ASTM B819. • Cap sections of tube and components that are not actively being installed to prevent infiltration of moisture and contaminants. • Use only braze alloys to join tube. - The selection of filler metals is highly dependent on the tube fit, clearance, and operator preference for flow. When flux is to be used, care should be taken to ensure that the flux is not introduced to the inside of the tube. It is recommended that phosphorous bearing alloys be considered for copper to copper connections due to their self -fluxing on copper to copper joints. Refer to alloy manufacturer's guidelines for details on compatibility. • Flow nitrogen into tubing to prevent the formation of copper oxides. - Copper oxides form rapidly when copper is heated to temperatures required by the brazing process and exposed to oxygen in the air. Copper oxides flake easily on the inside of the tubing and dislodge easily when the system is filled with refrigerant and oil. The particulate can move throughout the system and cause contamination on valves and other critical components. System filters may become fouled. - Flowing nitrogen into the system and ensuring that the inside of the tube is significantly free from oxygen while brazing ensures that oxides do not form. Schrader valves are placed throughout the system. These valves can be opened to allow for nitrogen to flow without generating pressure behind the braze joint that is being created. • See Section 5.1.1 for special procedures related to compressor replacements. • Replace liquid line filter dryer as last step in system repair. Note that the dryer will readily absorb moisture from the ambient air and must be open only for as long as required for installation. • After completion of all repairs, pressure test system using nitrogen pressure decay test or nitrogen with tracer gas and appropriate leak detector. Evacuation • Carefully inspect pump and related equipment before connecting to system. Ensuring gaskets are in good condition and pump is capable of low vacuum levels can save time. Connect pump(s) to Desert Aire - SA Manual 57 1/5/2016 as many locations as possible ensuring all locations are well sealed. If a field charge will be required, connecting a refrigerant tank to the system with a good valve is recommended. Any hose connections requiring purging of non-condensables can be done at this point. • Evacuate the line and remote condenser to 400 microns measured at a point on the system furthest away from the pump. - Note that a gauge installed on the pump or in close proximity will give a lower reading while the unit is being evacuated. - A deep vacuum gauge should be used to evaluate the pressure. Compound manifold gauges do not allow for enough accuracy at the pressures required. - The system should be able to hold a vacuum under 500 microns for more than 10 minutes. - If pressure continuously rises at a rapid rate there is likely a system leak. Review all piping connections and correct before continuing evacuation. - Pressure rising above 500 microns and tending to stabilize at a higher pressure indicates the system has moisture above specifications. Continue evacuation until 500 microns or lower can be held for a minimum of 10 minutes. Alternate Evacuation Specification by Process After components have been repaired or replaced, the evacuation procedure should take place. Very small amounts of refrigerant may still be mixed with the oil in the system. Out -gassing of this refrigerant may interfere with the evacuation and vacuum decay testing. IF, AND ONLY IF, a unit has been previously charged with refrigerant, and standard evacuation method has not been successful after 24 hours minimum using the standard procedure, the following alternate method should be used. 1. Check vacuum level. It should be a maximum of 1,500 microns absolute pressure. If this is not the case, review system for leaks and continue evacuation process until 1,500 microns is achieved. 2. Purge system with nitrogen to atmospheric pressure (0 gauge pressure). Ensure all portions of systems are at this pressure. Seal system and wait 10 minutes. 3. Start vacuum pump and draw system to 1,500 microns or less. 4. Purge system with nitrogen to atmospheric pressure (0 gauge pressure). Ensure all portions of systems are at this pressure. Seal system and wait 10 minutes. 5. Start vacuum pump and draw system to 500 microns. Seal system. System may rise to higher level, but should not rise above 1000 microns in 10 minutes timeframe. If unsuccessful, continue evacuation or check for leaks. It is anticipated that the system was clean and tight from the original process and refrigerant only is mixed with oil. Alternate process should not be considered if there is chance of free water entering the system or the system was open for any significant time. 58 Desert Aire - SA Manual 1/5/2016 Charging Charge should be weighed into the system using a scale. In cases where the full charge was recovered, weigh in the charge with the recovered refrigerant and add the appropriate amount to meet the rating plate and field charge (if applicable). This should be placed in the high side of the system at the receiver. In cases where the full charge cannot be added to the system high side, the charge can be added to the low side of the system only when compressors are energized. If this is required, the compressors should be energized and the charge should be slowly metered into the suction line as far as possible upstream of the compressor. If the unit is equipped with an accumulator, the charge needs to be added to the port upstream of this location. The bulkhead fittings on the side of the unit should not be used for charge addition. Monitor superheat at the compressor suction inlet using the bulkhead fitting and a temperature sensor on the suction line near the compressor. Superheat should not drop below 10 degrees during the process of adding charge. Testing and Final Diagnosis Check the oil level in the compressor after the system has been running for 24 hours. Oil may have been contained in the liquid refrigerant when recovered from the system. Most of this oil will be returned if the recovered refrigerant is used. If new refrigerant is added, additional oil should be added based on the following ratio: New Refrigerant Charge Added, lbs. x 0.352 = Oil charge, oz. It is of critical importance to ensure that the system is operating as expected before unit is returned to normal service. Test component replaced and function of the system. Many times a separate component in the system may have set a condition that causes the failure of another. Thoroughly test systems to ensure repeat failures do not occur. Desert Aire - SA Manual 59 1/5/2016 5.7 System Rating Plate The system rating plate is attached near the electrical enclosure of the dehumidifier. ^r System model and ' 11 serial numbers DESERT Model No. SA50S4AAXXI4072 Serial No. XXXXEXXXX AME System electrical specifications y Voltage/Phase/Hz. 460/3/60 Control Voltage 24 Minimum Ampacity 123 Maximum Fuse 150 Blowers) electrical Compressors Blower(s) r specifications Compressor Mtr# RLA LRA Mtr# HP FLA electrical 2 18.3 127 1 20 25.0 specificationsy 3 18.3 127 6 N/A N/A Electric heater 4 26.4 187 7 N/A N/A electrical 5 26.4 187 specification Refrigerant Electric Heater factory charge Factory Charge (lbs.) KW 15 FLA 19.5 Circuit A 66 a — Refrigerant type Circuit B 101 R410A ONLY Maximum Design Pressures(psig): 400 High Side 150 Low Side System working System wiring pressure range diagrams Wiring Diagram Numbers: HNS-340 / 8584LV / 8584AHU This Unit Is For Outdoor Use Indoor or Outdoor Desert Aire Corporation system rating N120 W18485 Freistadt Road Germantown, WI 53022 (262) 946-7400 Fax: (262) 946- 7401 Figure 28 - Typical SA Dehumidifier Rating Plate 5.8 Start -Up Supervision Supplemental Information A Desert Aire factory start-up is an option which is normally purchased with the equipment. A factory start-up includes several key services: • The expertise of an accomplished, factory -trained mechanic who will supervise the commissioning of the equipment. • This Desert Aire representative will assist the installing contractor with filling out the Start -Up Report. • He will also inspect the installation to make sure that the dehumidifier has been properly integrated with the rest of the equipment on the jobsite. • Finally, he can train the maintenance personnel to operate and service the equipment if necessary. Afactory start-up does not include installation assistance. The installing contractor is responsible for ensuring that the system is ready for start-up when the Desert Aire representative arrives. When the installing contractor is confident the system will be ready, he should contact the Desert Aire Sales representative to schedule the start-up. Please call at least two weeks before the desired start-up date to help prevent scheduling conflicts. Desert Aire - SA Manual 1/5/2016 Start-up request form for pool room N120 W18485 Freistadt Road DIESIERY Germantown, WI 53022 units � (262) 946-7400 FAX: (262) 946-7401 '� Models LC/LV/ND/SA www.desert-aire.com Factory Assisted Start -Up consists of a Desert Aire Service Department Technician to visit the job -site and provide supervisory experience to installing contractors as they perform the required procedures as outlined in our warranty activation start-up report. The company technician will also present an educational review of the dehumidifier's operating and maintenance requirements. Factory Assisted Start -Up is not an installation bid & therefore the system must be ready to run before scheduling. CST Start -Up is performed by a local Certified Service Technician who has been trained by Desert Aire. The CST performs all duties listed above. In addition they will supply the "items to be supplied for start-up" as listed below. Please note charges for refrigerant will apply if refrigerant is necessary to complete the start up. Items to be completed by the installing contractor before any Start -Up can be scheduled: ❑ Dehumidifier leak checked and inspected for internal concealed damage — remove access panels and inspect the interior of the unit for transit damage. Contact Desert Aire immediately if damage is noted (800) 443-5276 ❑ Dehumidifier leveled and properly supported per the installation manuals recommendations. ❑ Outside air duct filters and damper installed (if applicable) — See installation manual. ❑ Condensate P Trap installed with heat trace for winter operation. ❑ Remote condenser plumbed, leak checked, evacuated, and charged if necessary. LC and LV Units require additional field charging. Refer to the 1/0 manual for details. Refrigerant added Ibs.(if applicable) ❑ All electrical connections terminated and verified for proper voltage at the unit and the condenser (if applicable) ❑ All field controls, sensors and actuators installed and circuits verified that they are wired correctly. Note: Zone sensors and controllers are shipped separately to ensure delivery. If the controllers are not located on site, please contact Desert Aire to confirm delivery status. (800) 443-5276 ❑ Pool filled, water and air temp minimum 80 degrees. (If applicable) ❑ Pool water heating circuit connected to dehumidifier with flow meter and balancing valves installed in circuit (if applicable) ❑ Verify the installation of the booster pool water -heating pump and purge air from water the lines. (If applicable) Items to be supplied by the installing contractor (Factory Assisted Start -Up only) ❑ Equipped service vehicle and service technician — Technician will be trained. ❑ Refrigerant manifold gauges — 2 sets ❑ Air balancing equipment (magnehelic or manometer differential pressure gauge — one inch scale) ❑ Volt/Amp/OHM meters in working order. ❑ Digital thermometer with sensors. ❑ 50# of the appropriate refrigerant & scale. ❑ Hand pump for adding oil to compressors. ❑ One gallon POE oil — Use POE 32 MAF If you are unable to supply any of the required equipment you must contact Desert Aire before returning this document. I agree that all of the above has been completed as of (Date) If a return trip must be scheduled due to insufficient job -site preparation an additional purchase order must be issued to Desert Aire for re -scheduling. A two week minimum is needed to schedule start-up. Once the form is completed please fax or email both pages to the Desert Aire service department. Fax (262) 946-7400 Email: service(a)desert-aire.com Jobsite Manager's Signature: Company Name:, (print) Phone #: (sign) SB -010 Desert Aire - SA Manual 61 1/5/2016 DEAK UJART J Unit Information Jobsite Information Start-up request form for pool room units Models LC/LV/ND/SA Model # Serial # Job site name Job Site Address Contractor Information Installing Contractor: Manager's Name: Phone Job Site Contact: Cell # Controls Company Name Controls Contact: Test and Balance Company: Cell# Cell# N120 W18485 Freistadt Road Germantown, Wi 53022 (262) 946-7400 FAX: (262) 946-7401 www.desert-aire.com Factory use only — To be filled out by Desert Aire Scheduled Start-up Date: Unit Controls Protocol: JCI Metasys JCI FX Carel Honeywell Other: Diagrams Forwarded to CST: Yes / No email address Installing Contractor Contacted by: Date: Network to be operational at time of start up: yes / no T&B to be on site during start up: yes / no Additional Information: SB -010 62 Desert Aire - SA Manual 1/5/2016 5.9 System Start -Up Report A copy of the system "Start -Up Report" can be found on the following pages. This report needs to be filled out thoroughly by a qualified service technician and returned to Desert Aire for warranty validation. Please ensure that the model and serial number of the unit are noted on this form. The model and serial number can be found on the system's rating plate located on or near the electrical compartment service door. Failure to complete and return this form will void the unit's warranty. These reports are also helpful when trying to correct existing problems. Should you need system diagnosis help, fax the completed worksheet to Desert Aire's Service Department using the number provided. Be sure to include your name and a telephone number where you can be reached. Desert Aire - SA Manual 63 1/5/2016 'll DESERT /SIRE SA Series Start up Report Important — To ensure warranty validation and continued customer satisfaction, complete this form and return it to Desert Aire immediately after start-up. Validation of this report activates the warranty. Desert Aire Corporation c/o Service and Warranty Department N120W18485 Freistadt Road Germantown, WI 53022 (800) 443-5276 Instructions • Warning — Only trained, qualified personnel should install and service Desert Aire equipment. Serious Injury or death can result from improper handling of this equipment. High voltage electrical components and refrigeration under pressure are present. • Before continuing, read the Installation and Operations manual. If you do not fully understand the manual contact the Desert Aire Service Department. Please be prepared with the model and serial numbers located on the rating plate of the unit. • Use one start up report per unit. Print or type all information. If there is not enough space available for readings or comments please attach additional pages directly to the start up report. Installation Name: Installation Address: Desert Aire Representative: Dehumidifier Model #: Location and Unit Information Serial #: Remote Condenser Model #: Serial #: Form Completed By (Print): Company Name: Company Address: Application (Pool, Spa, Other): 64 Desert Aire - SA Manual Signed: Date: Telephone #: Fax #: ( ) 1/5/2016 * Denotes that this is a model dependant item Proper Installation Checklist Installation manual read and ° understood Dehumidifier installed and ° leveled properly Condensate drain trapped ° and primed Verify that the power supply ° matches the rating plate Tighten all field and factory ° wiring Adjust and tighten blower ° belts if necessary Check rotation of blower on 3 ° phase units Check rotation of remote ° condenser fans. Open all refrigeration service ❑ valves and tighten packing nuts Check field and factory piping ° for leaks Inspect air filters. Clean or ° replace as necessary 120 volt circuit run to heat ° trace and powered up. Unit Power Supply Information Voltage at power block - NL2-L3 No motors running L1-L2 Control Voltage - No Motors running Transformer 1 VA Rating Yes / No Transformer VA Rating L1-L3 Transformer 3 VA Rating Line -set Installation — Refer to Installation and operation manual for instructions Lineset Length SN -1 Elevation Change ABOVE / BELOW Hot gas line trapped at every riser Yes / No Inverted traps at top of risers Yes / No Line -set pitched in direction of flow Yes / No Line -set Clamped per 1/0 Manual Yes / No Line Sizes Circuit A Circuit B Hot Gas SNF' Hot Gas OUTR2 Liquid Return Liquid Return Additional R41 OA Added LBS LBS Additional Oil Added ONT' ozs ozs Flush Cycle Enabled Yes / No Yes / No Fan Cycle Controller Settings — Refer to Installation and operation manual for instructions SENS SN -1 SN -2 SN -3 OUTR' ON' OFF' ONT' OFT' SNF' SENS' OUTR2 ON' OFF' ONT' OFT' SNF' SENS' OUTR3 ON' OFF' ONT3 OFT' SNF' SENS' OUTR4 ON" OFF' ONT' OFT' SNF' SENS' Desert Aire - SA Manual 65 1/5/2016 Air Flow Readings: Refer to Installation and Operations manual for correct balancing procedures. Evaporator Pressure Drop °wc Supply Duct Static Pressure "WC Reheat Condenser Pressure Drop "wc Return Duct Static Pressure "WC VOC as read off the display' ppm VOC Setpoint" ppm Airflow Settings: Refer to Installation and Operations manual for correct balancing procedures. Amperage at Design Airflow Unoccupied Occupied Event Max OA Purge Design OA CFM CFM CFM CFM CFM Actual OA CFM CFM CFM CFM CFM OA Setpoint °wc I'M °wc we °wc Damper Pos Design Exhaust CFM CFM CFM CFM CFM Actual Exhaust CFM CFM CFM CFM CFM Low VFD Command % % % /o o a /o Exhaust.VFD % % % /o o /o % Blower Information Amperage at Design Airflow Supply Blower Exhaust Blowers* L1 L1 L1 L2 L2 L2 L3 L3 L3 Temperature Readings Room Air Temperature T Room Relative Humidity T Outdoor Air Temperature T Outdoor Relative Humidity T Water Temp (main pool) T Water temp (spa or other)* °F 66 Desert Aire - SA Manual 1/5/2016 Compressors and Refrigeration in Reheat Mode e ex Motor # Circuit A Circuit B RLA off nameplate ams ams ams amps Amperage L1 L1 L1 L1 L2 L2 L2 L2 L3 L3 L3 L3 Head Pressure Psig Psig Suction Pressure Psig Psig Refrigerant Sight Glass Clear Yes / No Yes / No Superheat T T Subcooling T °F Compressor Oil Level Sight Glass (level should be at least 3/4 full at completion of the start up) �/z 3/a F '/z 3/a F Compressors and Refrigeration in Pool Water Heating Mode 'kg- `� r Circuit A Circuit B Head Pressure Psig Psig Head Pressure Psig Psig Suction Pressure Psig Psig Water Inlet Temperature T T Water Outlet Temperature T T Compressors and Refrigeration in Cooling Mode* (Remote Condenser Active) 40, 94 _ Circuit A Circuit B Head Pressure Psig Psig Suction Pressure Psig Psig Refrigerant Sight Glass Clear Yes / No Yes / No Superheat T °F Subcooling T T Compressor Oil Level Sight Glass (level should be at least 3/4 full at '/z % F '/2 % F '/z % F '/z '/ F Desert Aire - SA Manual 67 1/5/2016 Auxiliary Water I Steam Coil Information* Signal Inlet Temp Outlet Temp Discharge Air Temp Water Coil T T T Steam Coil T T T Auxiliary Electric Heater Information* Signal L1 Amps L2 Amps L3 Amps Discharge Air Temp Electric Heater BACnet MS/TP Device Instance T Building Management System Information* Communication Type BACnet MS/TP - BACnet Ethernet - Modbus - Lon - N/A (circle one) BACnet MS/TP Device Instance MAC Address y Baud Rate BACnet Ethernet IP Address Netmask Gateway Modbus Baud Rate Address Additional Comments: 68 Desert Aire - SA Manual 1/5/2016 1 i1 DE ARE A Compressor Replacement Form Important — To ensure warranty validation and continued customer satisfaction, complete this form and return it to Desert Aire immediately after any compressor replacements. Validation of this report allows for the continued coverage of the compressor under the original warranty. For units that are outside the warranty period, returning the form to Desert Aire assists in service history and confirmations that the unit is operating properly. Desert Aire Corporation. c/o Service and Warranty Department N120 W18485 Freistadt Rd Germantown, WI 53022 (800) 443-5276 Instructions • Warning — Only trained, qualified personnel should install and service Desert Aire equipment. Serious Injury or death can result from improper handling of this equipment. High voltage electrical components and refrigeration under pressure are present. • Before continuing, read the Installation and Operations manual. If you do not fully understand the manual contact the Desert Aire Service Department. Please be prepared with the model and serial numbers located on the rating plate of the unit. • Use one start up report per unit. Print or type all information. If there is not enough space available for readings or comments please attach additional pages directly to the start up report. Installation Name: Dehumidifier Model #: Location and Unit Information Serial #: Form Completed By (Print): Signed: Company Name: Company Address: Date: Telephone #: ( ) Fax #: Desert Aire - SA Manual 69 1/5/2016 Diagnostic Summary Describe specific compressor failure type and cause. Indicate other components found to be defective and diagnostic procedures. Attach service report if available. Compressor Condition at Time of Initial Review Continuity (0 resistance) to Ground on one or more legs ❑ Continuity (0 resistance) between two or more legs (3 phase units) ❑ Compressor drawing higher current than design ❑ Compressor drawing locked rotor current ❑ Other (describe): ❑ 70 Desert Aire - SA Manual 1/5/2016 Compressor Replacement Checklist Required Choose One For Test Results Showing Acid or Particulate Acid and particulate test Unit Evacuated to 500 ❑ completed ❑ microns absolute and vacuum ❑ HH Cores used decay passed ❑ Liquid Line Filter Replaced ❑ Alternate triple evacuation ❑ SF filter used process used All Filters returned to original ❑ specifications after removal of contaminants Air Flow Readings: Refer to Installation and Operations manual for correct balancing procedures. Evaporator Static Pressure Drop "WC Reheat Condenser Static Pressure Drop "WC Supply Duct Static Pressure Drop "WC Return Duct Static Pressure Drop "WC Unit Power Supply Information Voltage at power block — No motors running L1-L2 L2-L3 L1-L3 Control Voltage — No Motors running Transformer 1 Transformer Transformer 3 Temperature Readings Room Air Temperature T Room Relative Humidity T Outdoor Air Temperature T Outdoor Relative Humidity T Water Temp (main pool) T Water temp (spa or other)" T Desert Aire - SA Manual 7 1/5/2016 Compressors and Refrigeration in Reheat Mode r Circuit A Circuit B _ _ PSIG PSIG Motor # see wiring schematic for details PSIG PSIG Suction Pressure L1-L2 L1-L2 L1-L2 Ll -L2_ Voltage measured with the Discharge Line Temperature of 6” from compressor discharge) compressors operating L2-L3 L2-L3 L2-L3 L2-L3 At access fittingnearest TXV °F Suction Temperature L1-L3 L1-L3 L1-L3 L1-L3 Sight Glass Condition L1 L1 L1 L1 Vapor, Flashing) Current ,/z 3/ F L2 L2 L2 L2 L3 L3 L3 L3 Discharge Pressure PSIG PSIG Liquid Line Pressure At access fitting nearest TXV PSIG PSIG Suction Pressure at compressor) PSIG PSIG Discharge Line Temperature of 6" from compressor discharge) T Liquid Line Temperature At access fitting nearest TXV T T Suction Temperature °F at compressor)of Refrigerant Sight Glass Condition Description (Clear, Intermittent Vapor, Flashing) Compressor Oil Level Sight Glass '/2 3/a F '/2 3/ F '/ 3/ F % Shut Down Compressors, Wait 5 Minutes Compressors and Refrigeration in Pool Water Heating Mode t„�, O,! Circuit A Circuit B Discharge Pressure PSIG PSIG Liquid Line Pressure At access fitting nearest TXV PSIG PSIG Suction Pressure at compressor) PSIG PSIG Discharge Line Temperature of 6” from compressor discharge) T Liquid Line Temperature of At access fittingnearest TXV °F Suction Temperature at compressor)Refrigerant T °F Sight Glass Condition Description (Clear, Intermittent Vapor, Flashing) Compressor Oil Level Sight Glass ,/z 3/ F '/z 3/ F '/z 3/ F '/2 3/ F Shut Down Compressors, Wait 5 Minutes 72 Desert Aire - SA Manual 1/5/2016 Compressors and Refrigeration in Cooling Mode* (Remote Condenser Active) 81 Circuit A Circuit B Relative Air Discharge Pressure PSIG PSIG Liquid Line Pressure Temperature (°F) 60.0-65.0 At access fitting nearest TXV PSIG PSIG Suction Pressure 85.1 - 90.0 at compressor) PSIG PSIG Discharge Line Temperature -F °F 6" from compressor discharge) 40.1 -50.0 Liquid Line Temperature -F °F At access fitting nearest TXV 16 18 Suction Temperature -F °F at compressor)Refrigerant Sight Glass Condition w� 10 Description (Clear, Intermittent 13 14 Vapor, Flashing) 16 18 Compressor Oil Level Sight Glass ,/2 3/ F F % 3/ F % % F Shut Down Compressors, Wait 5 Minutes 16 18 19 7- Note that superheat should be stable within 7 degrees. Minimum value for superheat at compressor in all modes: Subcooling shall be 4-14 degrees. Slight flashing in sightglass is acceptable if superheat and subcooling are within tolerance. Additional Comments: Desert Aire - SA Manual 73 1/5/2016 Superheat Minimum Values Chart Temp (°F) Relative Air Temperature (°F) 60.0-65.0 65.1 - 70.0 70.1 - 75.0 75.1 - 80.0 80.1 - 85.0 85.1 - 90.0 30.0-40.0 12 13 14 15 15 16 40.1 -50.0 13 14 15 15 16 18 w� 10 50.1 -60.0 13 14 15 16 18 18 i5 E 60.1 -70.0 14 15 15 16 18 19 7- 170.1 - 80.0 14 15 16 18 19 20 Subcooling shall be 4-14 degrees. Slight flashing in sightglass is acceptable if superheat and subcooling are within tolerance. Additional Comments: Desert Aire - SA Manual 73 1/5/2016 ;^ DESERT /SIRE N120 W18485 Freistadt Road • Germantown, WI 53022 • E-mail: info@desert-aire.com Ph: (262) 946-7400 • Fax: (262) 946-7401 • Website: www.desert-aire.com 0322014/02 1/5/2016 Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Resolution No. 38, Series of 2015, a resolution amending the Lionshead Redevelopment Master Plan to amend detailed plan recommendations for future development on the Evergreen at Vail development site, as prescribed in Chapter 5 of the Lionshead Redevelopment Master Plan, and setting forth details in regard thereto. PRESENTER(S): George Ruther, Director of Community Development ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny the resolution as presented. BACKGROUND: The applicant, Evergreen Lodge at Vail, represented by the Mauriello Planning Group, is requesting a public hearing with the Vail Town Council to present recommended amendments to Chapter 5, Detailed Plan Recommendations, subsection 5.19, Evergreen Lodge at Vail, of the Lionshead Redevelopment Master Plan. The four purposes of the amendments are to: 1. Clearly identify and articulate the desired outcomes of a future redevelopment of the Evergreen Lodge at Vail property, 2. Remove language from the Master Plan which is no longer relevant or applicable, 3. Respond to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establish predictability within the review process by providing detailed site specific recommendations for redevelopment of the Evergreen Lodge at Vail site. The requested amendments are as reflected in Resolution No. 38, Series of 2015. STAFF RECOMMENDATION: The Town of Vail Planning and Environmental Commission has forwarded a unanimous recommendation of approval of the requested amendments to the Vail Town Council. Based upon the input provided during the public hearings on this item on December 1 and December 15, 2015, the Community Development Department recommends the amendments and revisions made as reflected in Resolution No. 38, Series of 2015. ATTACHMENTS: Staff Memorandum Resolution No. 38, Series of 2015 010216 Evergreen Lodge Applicant letter 010416 Vail International Condominiums letter 1/5/2016 0 rowN of vaIt TO: Vail Town Council FROM: George Ruther, Director, Community Development Department DATE: January 5, 2016 SUBJECT: Resolution No. 38, Series of 2015 a proposed amendment to the Lionshead Redevelopment Master Plan, pursuant to Section 2.8, Adoption and Amendment of the Master Plan, Lionshead Redevelopment Master Plan, to amend the Detailed Plan Recommendations for the Evergreen Lodge at Vail, located at 250 South Frontage Road West/Lot 2W, Block 1, Vail Lionshead Filing 2, and setting forth details in regard thereto. (PEC140044) Applicant: Evergreen Lodge at Vail, represented by Mauriello Planning Group Planner: George Ruther I. SUMMARY The applicant, Evergreen Lodge at Vail, represented by the Mauriello Planning Group, is requesting approval of Resolution No. 38, Series of 2015. The purpose of this resolution is to adopt detailed plan recommendations for the Evergreen Lodge at Vail site within the Lionshead Redevelopment Master Plan (LRMP) study area. These amendments, if approved, become effective when the land exchange between the Vail Valley Medical Center (VVMC) and the Evergreen Lodge (EL) is finalized and a subsequent resubdivision plat is approved by the Town of Vail and executed and recorded with the Clerk and Recorder's Office of Eagle County. At this time, it is likely the land exchange will occur as conversations are ongoing and efforts are being made by all parties to execute a final agreement. This public hearing is the culmination of many three worksession meetings and a one final public hearing held on this topic with the Town of Vail Planning & Environmental Commission and three public hearings with the Vai Town Council II. DESCRIPTION OF REQUEST The applicant, Evergreen Lodge at Vail, represented by the Mauriello Planning Group, is requesting approval of Resolution No. 38, Series of 2015. The purpose of this resolution is to adopt detailed plan recommendations for the Evergreen Lodge at Vail site within the Lionshead Redevelopment Master Plan (LRMP) study area by amending. Chapter 5, Detailed Plan Recommendations, subsection 5.19, Evergreen Lodge at Vail, of the Lionshead Redevelopment Master Plan. The four purposes of the amendments are to: 1. Clearly identify and articulate the desired outcomes of a future redevelopment 1/5/2016 of the Evergreen Lodge at Vail property, 2. Remove language from the Master Plan which is no longer relevant or applicable, 3. Respond to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establish predictability within the review process by providing detailed site specific recommendations for redevelopment of the Evergreen Lodge at Vail site. III. PROPOSED AMENDMENTS The amendments proposed by the applicant, recommended by the Planning and Environmental Commission and further revised by the Vail Town Council have been drafted and will be presented assuming the proposed land exchange has occurred. Town staff recommends that any motion by the Vail Town Council approving or approving with modifications, of the requested master plan amendment contains a condition that said amendments are effective upon the date that the land exchange subdivision amendment is recorded at the Office of the Clerk and Recorder of Eagle County. RESOLUTION NO. 38 Series of 2015 A RESOLUTION AMENDING THE LIONSHEAD REDEVELOPMENT MASTER P LAN TO AMEND THE DETAILED PLAN RECOMMENDATIONS FOR FUTURE DEVELOPMENT ON THE EVERGREEN LODGE AT VAI L DEVELOPMENT SITE, AS PRESCRIBED IN CHAPTER 5 OF THE LIONSHEAD REDEVELOPMENT MASTER PLAN, AND SETTING FORTH DETAILS IN REGARD THERETO. WHEREAS, on December 15, 1998, the Vail Town Council (the "Town Council") adopted the Lionshead Redevelopment Master Plan (the "Master Plan"); and WHEREAS, the Master Plan was initiated by the Town of Vail to encourage redevelopment and new development initiatives within the Lionshead Study Area; and WHEREAS, Section 2.8 of Master Plan outlines a procedure for amending the Master Plan; and WHEREAS, pursuant to Section 2.8 of the Master Plan, the applicant Evergreen Lodge at Vail, represented by Mauriello Planning Group, has proposed an amendment to the Master Plan; and 1/5/2016 WHEREAS, the Town of Vail Planning & Environmental Commission has held four public hearings on the proposed amendment a n d on October 26, 2015, forwarded a recommendation of approval of the amendment to the Town Council; and WHEREAS, the purpose of this amendment isto amend the detailed plan recommendations for future development on the Evergreen Lodge at Vail development site, as prescribed in Chapter 5, Detailed Plan Recommendations, Lionshead Redevelopment Master Plan; and WHEREAS, the Town Council finds that the proposed amendment improves and enhances the effectiveness of the Master Plan and positively affects the goals, objectives, and policies prescribed in the Master Plan by: 1. Clearly identifying and articulating the desired outcomes of a future redevelopment of the Evergreen Lodge at Vail property, 2. Removing language from the Master Plan which is no longer relevant or applicable 3. Responding to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establishing predictability within the review process by providing detailed site specific recommendations for redevelopment of the Evergreen Lodge at Vail site. NOW, THEREFORE, BE IT RESOLVED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO: 1. Amendments: The V a i I Town Council of the Town of Vail hereby amends the Lionshead Redevelopment Master Plan as follows: 5.19 Evergreen Lodge at Vail The Evergreen Lodge at Vail is located directly east of the Middle Creek Stream Tract and is bordered to the north by the South Frontage Road and to the east by the Vail Valley Medical Center. The lot area is approximately 104,108 square feet in size or roughly 2.39 acres. Since the original inclusion in the Lionshead Redevelopment Master Plan, a portion of the Evergreen Lodge parcel, adjacent to the existing VVMC parking garage, was sold in 2014 to the Vail Valley Medical Center (VVMC). Additionally, in 2015, the Evergreen Lodge and the Vail Valley Medical Center, entered into an agreement to exchange land that resulted in the Evergreen Lodge acquiring a portion of the VVMC property south of the Evergreen Lodge and VVMC acquiring a portion of Evergreen Lodge land east of the Lodge. (See figure 1) The agreement was reached based on the conclusion of a two-day charrette between VVMC, Town of Vail, and the Evergreen Lodge representatives, which was conducted in December of 2014 where the parties developed an overall conceptual redevelopment scheme benefiting all parties. The resulting land area for the Evergreen Lodge is approximately 2.50 acres after the land trade. Physical improvements that currently exist on the site are a nine -story tall hotel/condominium structure containing 19 dwelling units and 128 accommodation units with an adjoining two-story tall hotel amenities wing containing a restaurant, cocktail lounge and bar, meeting rooms and conference facilities, twe-one below -grade structured parking garage containing 52 parking spaces, and paved surface parking comprised of 85 parking spaces. The nine -story tall structure has a predominant east -west orientation along the southerly edge of the site while the 1/5/2016 facilities wing has a north -south orientation along the westerly edge of the site. Vehicle access to the site is provided by two existing curb cuts along the South Frontage Road. No dedicated loading and delivery berths currently exist on the site. Delivery vehicles often are required to maneuver onto the site by backing in from the South Frontage Road. Opportunities for future improvements and upgrades include: • Elimination of surface parking and creation of more underground parking; • Enclosed Loading and Delivery; • Architectural enhancements consistent with the Lionshead Architectural Design Guidelines; • Improved exterior lighting; • Coordinated vehicular access and implementation of the Vail Streetscape Master Plan recommendations; • Creek improvements to improve health and access by the public; • Improved streetscape and landscaping along the South Frontage Road; • Improved pedestrian circulation along the South Frontage Road and connection to West Meadow Drive; and • Upgraded and expanded hotel accommodations and amenities, and inclusion of a flat floor conference area. 5.19.1 Pedestrian Access Pedestrian access should be upgraded to provide a safe and attractive pedestrian connection from the South Frontage Road, through the Evergreen Lodge development site and/or the adjacent tracts of land owned by the Town of Vail and the Eagle River Water and Sanitation District, to West Meadow Drive and with a continuous pedestrian/bicycle path along the South Frontage Road, consistent with the Town's proposed plans for a roundabout along the frontage of the Evergreen Lodge property (see figure 2) A gravel path connecting the South Frontage Road to the paved pedestrian path located on the east side of the Dobson Ice Arena presently exists along the south side of the property. This path, while functional, receives little, if any, regular maintenance and includes a railroad tie set of stairs that is unsafe and in disrepair. There are currently no pedestrian improvements located along the South Frontage Road along the Evergreen Lodge frontage. Though no improvements exist, a fair number of pedestrians use the southerly edge of the South Frontage Road when entering or exiting the site or while traveling past the property. In order to improve pedestrian access and safety, it is recommended that future redevelopment of the site includes the construction of a continuous pedestrian/bicycle path along the South Frontage Road and that the existing gravel path along the southerly edge of the site be improved and regularly maintained. Based on the results of the two-day charrette, the land trade provides an opportunity to create a pedestrian walkway from the South Frontage Road to West Meadow Drive as generally depicted in Figure 2 (see figure 2). Conceptually, the new walkway could benefit users of both the VVMC and the Evergreen Lodge properties while also allowing for access by the public. It may be necessary to utilize the Town owned Lot 10 to accomplish the desired pedestrian connection from South Frontage Road to West Meadow Drive, a desired public improvement. 5.19.2 South Frontage Road Improvements and Vehicular Access The site is currently accessed by vehicles from the South Frontage Road with two, full movement, access points. The current location of these access points relative to the 1/5/2016 existing access points for the US Bank Building, Vail Valley Medical Center parking structure, Town of Vail Municipal Buildings, and potential future access points to the Vail Valley Medical Center and Vail International Building results in undesirable traffic flow and turning movements creating traffic safety, capacity, and level of service concerns. In keeping with Policy Objective 2.3.4, Improved Access and Circulation, of the Plan, opportunities for public transportation and vehicular circulation improvements should be explored in conjunction with any future redevelopment of the site. Possible opportunities for improvements may include, an improved mass transit stop, relocated/reduced/shared points of entry/exiting, restricted access points, acceleration/ deceleration lanes, greater sight distances, dedicated turning lanes and landscaped medians, and the evaluation and possible implementation of an intersection solution, such as a roundabout. If constructed, a full, two lane roundabout could be located along the frontage of the Evergreen and Town of Vail Municipal site that takes into account the additional through - traffic needs of the community but also the future redevelopment of the Town's municipal site, VVMC, and the Evergreen Lodge properties. Additional study of the roundabout design is necessary. As envisioned, the roundabout and roadway improvements would allow for a primary right in, right out vehicular access and a separate right in, right out service vehicle access to the Evergreen Lodge property. The proposed roundabout as envisioned encroaches into the Evergreen Lodge property and the Town's municipal site which impacts the future development of the properties. In an effort to improve the pedestrian environment along West Meadow Drive and further reduce the total number of vehicle trips on West Meadow Drive, vehicular access to the Evergreen Lodge from West Meadow Drive shall be prohibited. 5.19.3 Preservation of Existing Accommodation Units The Evergreen Lodge presently contains 128 accommodation units. In addition, the Evergreen Lodge also contains a restaurant, cocktail lounge and bar and meeting rooms incidental to the operation of the Lodge. Originally built in 1974, the existing accommodation units and hotel amenities are old and outdated. The Lodge was developed to the standards desired more than four decades ago and likely no longer provides guests with accommodations meeting more modern standards and expectations. Given the importance and need for short-term accommodations to the vitality and success of the community, any future redevelopment of the site shall ensure, at a minimum, the preservation or replacement of the 128 short-term accommodation units on the site, in keeping with the live bed policy in Section 4.13. The preservation of short term accommodations should focus on maintaining the number of accommodation units. While the development trend in Vail since the late 1990's has been to focus on high-end, luxury accommodation units utilizing more floor area per unit, an opportunity exists to create high quality accommodation units that are smaller in size, and potentially greater in number, and likely to be more affordable, yet achieve the goals of preserving the existing number of accommodation units, maintaining live beds on the site, and increasing the revenues and vitality of the Town. Opportunities for increasing the number of accommodation units beyond the existing 128 units already on-site should be evaluated during the development review process. For example, the construction of "attached accommodation units", or the provision of a rental management program, could significantly increase the availability of short-term rental opportunities through redevelopment. 5.19.4 Impacts on Middle Creek Stream Tract 1/5/2016 The Middle Creek Stream Tract lies to the west of the Evergreen Lodge. The Tract is made up of two parcels. One owned by the Town of Vail and the other by the Eagle River Water and Sanitation District. The Tract is heavily vegetated with deciduous trees, a significant lower layer of riparian underbrush and also includes a pedestrian path and a pedestrian bridge. Given the importance of water quality, it is imperative that any future development on the Evergreen Lodge site does not negatively impact or encroach upon the existing riparian corridor of Middle Creek and that it comply with any stream health initiatives, including any amendments to the watercourse setback requirements that may be adopted town wide. Although the site borders the Middle Creek Stream Tract, there is no significant amount of quality vegetation on the site and the parcel lies out of the 100 - year flood plain. As currently configured, opportunities exist to better recognize the benefits of creek side development and to improve and enhance the riparian corridor to address the overall health of the Creek. For purposes of this master plan recommendation, the riparian corridor shall be defined as the Middle Creek Stream Tract. While the riparian corridor of Middle Creek shall remain protected and preserved, the physical and visual relationships and references between adjacent development and the Tract should be strengthened. Careful consideration should be taken when approving any application for development adjacent to Middle Creek. Any future development application for the redevelopment of the Evergreen Lodge site shall be accompanied by an environmental impact report consistent with the requirements prescribed in Chapter 12, Environmental Impact Reports, Title 12, Zoning Regulations, Vail Town Code. An opportunity exists to create a significant connection between the Evergreen Lodge and Middle Creek. Any use of Middle Creek for aesthetic or recreational purposes, however, should be subordinate to the preservation of the natural riparian corridor and its inherent natural character. The Middle Creek Stream Tract provides an opportunity for the construction of a recreational path connecting the South Frontage Road and uses on the Evergreen Lodge property to the existing pedestrian paths at the Dobson Ice Arena providing a strong pedestrian connection to West Meadow Drive. 5.19.5 Relationship to the Vail Valley Medical Center and the Vail International Perhaps the most critical functional relationship is the need to coordinate any future development on the Evergreen Lodge site with the Vail Valley Medical Center. For example, opportunities for coordination may include, shared service and delivery facilities, grading and site improvements, shared parking, and pedestrian pathway connections. Both parties have taken steps to ensure the properties can be redeveloped in a more coordinated manner by executing the land exchange. The land exchange provides better access length, frontage, and redevelopment opportunities to the Vail Valley Medical Center by securing additional South Frontage Road access and providing more flexibility in the design of a possible East Wing of the VVMC. The exchange of land affords an opportunity to accommodate an important pedestrian connection from the South Frontage Road to West Meadow Drive, thereby strengthening the pedestrian connection into Lionshead and Vail Village. The land exchange also allows for improved vehicular access by providing a reasonable location for a roundabout located in front of and on the Evergreen Lodge property improving access to both properties. This pedestrian connection could potentially utilize a one-story deck that could cover surface parking on the VVMC campus. While a deck provides covered parking screened from public view, it also introduces a landscape element and plaza benefiting the views and use by patrons from Evergreen Lodge, VVMC, and the community at large. In order for a connection and landscape enhancement to be successful, it may require that it to be developed with reduced or zero setbacks between the properties and may require stairs and elevator access on or adjacent to Lot 10. 1/5/2016 The Vail International is located across from to the Evergreen Lodge site on the west side of the Middle Creek Stream Tract. Building bulk, mass and scale on the Evergreen Lodge site is affected by the need for the emergency helipad located on the Vail Valley Medical Center property and the requirement that any future building on the exchange parcel steps down towards West Meadow Drive to create an appropriate pedestrian scale. These two design considerations result in the greatest building bulk, mass and scale being located in the northwest corner of the Evergreen Lodge development site. During the development review process, the DRB and the PEC shall pay special attention to the western facade of any new or redeveloped structure to ensure it is appropriately articulated to provide visual interest, shadow lines and avoids large unbroken wall planes. For the portion of the development along the Middle Creek Stream Tract building facades facing west towards the stream corridor should step back from the Creek to ensure adequate sunlight reaches the ground and there should be a clear separation, most likely a native landscape buffer, between the public and the private spaces. 5.19.6 Service and Delivery Service and delivery functions for the hotel are currently accommodated on grade from the westerly entrance to the property. Service and delivery for the redeveloped Evergreen Lodge shall occur within the structures or and otherwise be adequately screened from public view. Service and delivery truck turning maneuvering shall not negatively impact traffic flow on the South Frontage Road and a separate loading and service entry may be allowed in conjunction with the construction of a potential new roundabout in this location. 5.19.7 Setbacks Special consideration should be given to the setback of buildings from the South Frontage Road. Pursuant to the Lionshead Mixed Use -1 zone district setback standards, a minimum 10 -foot (10') setback is required. Given the relationship of the development site to the South Frontage Road, the need for adequate area for vehicular traffic circulation, the importance of a landscape area to visually screen the massing of the building, and the existence of a 30 -foot wide utility easement along the southerly edge of the South Frontage Road, the minimum required front setback for the Evergreen Lodge development site shall be thirty feet (30'). This increased setback requirement shall supersede the 10 -foot setback requirement prescribed in Section 12-71-1-10, Setbacks, Vail Town Code. Based upon the coordinated efforts between the Evergreen Lodge and the Vail Valley Medical Center, opportunities exist for a covered parking deck and pedestrian access landscape plaza to be developed between the properties with the goal of screening surface parking and enhancing the visual quality of the area. If appropriately designed, a reduced or zero set back in these areas may be proposed for review during the development review process. Additionally, below grade improvements, including but not limited to, parking and vehicular circulation improvements may be developed within the required setbacks, if found to be consistent with the Town's development objectives. 5.19.8 Architectural Improvements and Building Heights 1/5/2016 The architectural design guidelines (Chapter 8) discuss several transition tools that can be used to adapt an existing building to the new character and architectural quality desired for Lionshead. Given the high visibility of the buildings on this site and the extent to which they influence the quality of the experience of passers-by, all future development on the site should be closely scrutinized for compliance with the applicable architectural design guidelines. That said, the Evergreen Lodge is located in a transitional area with VVMC, the Library, and Dobson Arena, which tend to have more modern or institutional architecture. The building will need to have a relationship to adjacent buildings and pedestrian corridors. With the addition of the land acquired from the Vail Valley Medical Center, the Evergreen Lodge has the opportunity to step building mass down towards West Meadow Drive in a north/south orientation. Building mass should step down from the South Frontage Road to the south boundary of the Evergreen Lodge property. The building on the land exchange parcel should step down to a maximum of four and five stories with complementary roof forms to achieve a pedestrian scale building, consistent with the west wing of the medical center (see figure 3), and subject to design review. The final building massing, scale and form shall be determined during the development review process. 5.19.9 Public Transit Stop A public transit stop is presently located east of the US Bank Building, across the street from the Town Municipal offices. Through the future redevelopment of the Evergreen Lodge and the Vail Valley Medical Center, an opportunity exists to potentially relocate the transit stop to a more optimal location. 1/5/2016 rowN of vain Um _.—'� �" •,....='R�PHITY LITE '�"`�'.� - \ Vreveaed Fewn Rwndabeue Yewnwva lsenam Tnm� r , and rrad.am I �•.-=,rf�. � � <. e D a.n. Tra a ^�• . WTE ,. 5 �. � �. f YeilVakry McSpF Ceree � -- i 7 A/(�.t '� \,- - _ �r I�- _ ~I•- ce y _ �1 Figure 1 Figure 2 1/5/2016 T.—d Vyl Strwn T— A", p 1 North ! South Connection r r' to Meadow Drive:j CiR1V3a5trram Trxs� - �Wa_„�"' - _ WEST MEADOW DRI1jE SOUTH FRONTAGE ROAD 819a Sidewalk Town of Vail WEST MEADOW DRIVE $142' Evergreen Lodge Conceptual Building Height I'°' Evergreen Lodge Parcel Easement Figure 3 Trade Parcel "x Lot 10 Sekba& PTO Page 10 1/5/2016 2. Effective Date: This Resolution shall become effective upon the date that the land exchange subdivision amendment (the "resubdivision map") with the Vail Valley Medical Center is duly recorded at the Office of the Clerk and Recorder of Eagle County, Colorado. The condition approval of this Resolution shall expire on December 31, 2020 (the "expiration date") unless the resubdivision map is recorded as required prior to the expiration date. INTRODUCED, READ, APPROVED AND ADOPTED this 5th day of January, 2016. Dave Chapin, Mayor, Town of Vail ATTEST: Patty McKenny, Town Clerk V. BACKGROUND The Evergreen Lodge was previously zoned Special Development District No. 14 with an underlying zoning of High Density Multiple -Family. The Special Development District (SDD) was established via Ordinance No. 5, Series of 1986. The SDD permitted 128 accommodation units, 19 dwelling units, a restaurant, lounge, spa, and meeting room/conference facility space. On December 20, 2005, Resolution No. 23, Series of 2005, was approved by the Vail Town Council amending the Lionshead Redevelopment Master Plan to include detailed plan recommendations for the Evergreen Lodge site and amend the boundaries of the Lionshead Study Area. Additionally, Ordinance No. 30, Series of 2005, was adopted establishing Lionshead Mixed Use 1 District zoning for the Evergreen Lodge parcel. On August 10, 2015, the Planning and Environmental Commission held a worksession to begin discussion regarding the proposed master plan amendment application. As a result of the worksession and public comment, a number of questions and issues were raised. On September 14, 2015, the Planning and Environmental Commission held a Town of Vail Page 11 1/5/2016 worksession to continue discussions regarding the proposed master plan amendments. As an outcome of the worksession, the Commission voted unanimously to continue the public hearing. On September 28, 2015, the Planning and Environmental Commission held a worksession to continue discussions regarding the proposed master plan amendments. In sum, the Commission recommended a number of changes be made to the amendments to provide less specificity with regard to certain plan recommendations. The Commission's preference was to have document more general in nature while still proposing possible or potential options and solutions. On October 26, 2015, the Planning and Environmental Commission held a public hearing on the request to amend the Lionshead Redevelopment Master Plan regarding the future redevelopment of the Evergreen Lodge at Vail. Upon final review, the Commission voted unanimously to forward a recommendation of approval of the proposed amendment to the Vail Town Council. On December 1 and 15, 2015, the Vail Town Council held two public hearings on the request to amend the Lionshead Redevelopment Master Plan. Based upon input from the Town Council and members of the public participating in the hearings, several revisions were made to the proposed language. The revisions mainly focused on impacts to Middle Creek, stream course setbacks, and impacts on adjacent properties and structures. VI. APPLICABLE PLANNING DOCUMENTS Staff believes that the following provisions of the Vail Town Code are relevant to the review of this proposal: TITLE 12: ZONING REGULATIONS Article 12-71-1 Lionshead Mixed Use 1 (LMU-1) District (in part) 12-71-1-1: PURPOSE: The Lionshead mixed use 1 district is intended to provide sites for a mixture of multiple - family dwellings, lodges, hotels, fractional fee clubs, timeshares, lodge dwelling units, restaurants, offices, skier services, and commercial establishments in a clustered, unified development. Lionshead mixed use 1 district, in accordance with the Lionshead redevelopment master plan, is intended to ensure adequate light, air, open space and other amenities appropriate to the permitted types of buildings and uses and to maintain the desirable qualities of the zone district by establishing appropriate site development standards. This zone district is meant to encourage and provide incentives for redevelopment in accordance with the Lionshead redevelopment master plan. This zone district was specifically developed to provide incentives for properties to redevelop. The ultimate goal of these incentives is to create an economically vibrant Town of Vail Page 12 1/5/2016 lodging, housing, and commercial core area. The incentives in this zone district include increases in allowable gross residential floor area, building height, and density over the previously established zoning in the Lionshead redevelopment master plan study area. The primary goal of the incentives is to create economic conditions favorable to inducing private redevelopment consistent with the Lionshead redevelopment master plan. Additionally, the incentives are created to help finance public off site improvements adjacent to redevelopment projects. With any development/redevelopment proposal taking advantage of the incentives created herein, the following amenities will be evaluated: streetscape improvements, pedestrian/bicycle access, public plaza redevelopment, public art, roadway improvements, and similar improvements. LIONSHEAD REDEVELOMENT MASTER PLAN 2.3 Policy Objectives The Town Council adopted six policy objectives on November 4, 1996 to outline the important issues to be addressed in the master plan and to provide a policy framework for the master planning process. 2.3.1 Renewal and Redevelopment Lionshead can and should be renewed and redeveloped to become a warmer, more vibrant environment for guests and residents. Lionshead needs an appealing and coherent identity, a sense of place, a personality, a purpose, and an improved aesthetic character. 2.3.2 Vitality and Amenities We must seize the opportunity to enhance guest experience and community interaction through expanded and additional activities and amenities such as performing arts venues, conference facilities, ice rinks, streetscape, parks and other recreational improvements. 2.3.3 Stronger Economic Base Through Increased Live Beds In order to enhance the vitality and viability of Vail, renewal and redevelopment in Lionshead must promote improved occupancy rates and the creation of additional bed base ("live beds" or "warm beds') through new lodging products. Live beds and warm beds are best described as residential or lodging rooms or units that are designed for occupancy by visitors, guests, individuals, or families on a short term rental basis. In order to improve occupancy rates and create additional bed base in Lionshead, applications for new development and redevelopment projects which include a residential component shall provide live beds in the form of accommodation units, fractional fee club units, lodge dwelling units, timeshare units, attached accommodation units (i.e, lock -off units), or dwelling units which are included in a voluntary rental management program and available for short term rental. Further, it is the expressed goal of this Plan that in addition to creating additional bed base through new lodging products, there shall be no net loss of existing live beds within the Lionshead Redevelopment Master Plan study area. Town of Vail Page 13 1/5/2016 2.3.4 Improved Access and Circulation The flow of pedestrian, vehicular, bicycle and mass transit traffic must be improved within and through Lionshead. 2.3.5 Improved Infrastructure The infrastructure of Lionshead (streets, walkways, transportation systems, parking, utilities, loading and delivery systems, snow removal and storage capacity) and its public and private services must be upgraded to support redevelopment and revitalization efforts and to meet the service expectations of our guests and residents. 4.13 Live Beds The maintenance, preservation, and enhancement of the live bed base are critical to the future success of Lionshead and as such, special emphasis should be placed on increasing the number of live beds in Lionshead as the area undergoes redevelopment. The Lionshead area currently contains a large percentage of the Town's overall lodging bed base. The bed base in Lionshead's consists of a variety of residential and lodging products including hotels, condominiums, timeshares and hybrids of all three. The vast majority of live beds in Lionshead are not accommodation units in hotels, but instead, in dwelling units in residential condominiums such as the Vail 21, Treetops, Antlers Lodge, Lion Square Lodge, Lifthouse Lodge, Landmark Tower and Townhomes, Lionshead Arcade, and Montaneros, all of which have some form of rental/property management program that encourages short term rental of dwelling units when the owners are not in residence. It has been the experience in Lionshead that condominium projects which include a voluntary rental management program have occupancy rates which exceed the occupancy rate of hotel products, and therefore tend to provide more live beds and produce more lodging tax revenues to the Town. Applications for new development or redevelopment which maintain, preserve, and enhance the live bed base in Lionshead have a significantly greater chance of approval in the development review process than those which do not. 4.13.1 Live Bed Definition Pursuant to Policy Objective 2.3.3, live beds (and warm beds) are defined as residential or lodging rooms or units that are designed for occupancy by visitors, guests, individuals, or families, on a short term rental basis. A live bed may include the following residential products: accommodation units, fractional fee club units, lodge dwelling units, timeshare units, attached accommodation units (i.e., lock -off units), and dwelling units which are included in a voluntary rental management program and available for short term rental. 4.13.2 Location of Live Beds Town of Vail Live beds should be located in Lionshead pursuant to the Lionshead Mixed Use 1 and 2 zone districts. All properties within Lionshead, when developing or redeveloping and providing new residential or lodging products, should provide live beds as defined herein. Page 14 1/5/2016 4.13.3 Hotel -types of Services and Amenities To aid in the furtherance of Policy Objective 2.3.3 of the Plan, the creation of additional live beds should include hotel -types of services and amenities. Such services and amenities may include, but not be limited to, the operation of a front desk, registration/reservation capabilities, recreational amenities, guest drop-off, on-site management, etc. These types of services and amenities in multiple family residential dwellings will increase the likelihood that the dwelling units will be made available for short term occupancy and help to promote improved occupancy rates. 4.13.4 Review of New Development and Redevelopment Projects The Planning and Environmental Commission shall consider the policies and direction given by this Plan with respect to live beds when reviewing new development and redevelopment projects in Lionshead. Applications for new development or redevelopment shall maintain the live bed base in Lionshead. Applications for new development and redevelopment which enhance the live bed base have a significantly greater chance of approval in the development review process than those which do not. A proposal's adherence to the policies contained in the adopted master plan will be one of the factors analyzed by staff, the Planning and Environmental Commission (PEC), the Design Review Board (DRB), and the Town Council (as applicable) in determining whether to approve or disapprove the specific proposal. VAIL LAND USE PLAN CHAPTER 11— LAND USE PLAN GOALS / POLICIES: The goals articulated here reflect the desires of the citizenry as expressed through the series of public meetings that were held throughout the project. A set of initial goals were developed which were then substantially revised after different types of opinions were brought out in the second meeting. The goal statements were developed to reflect a general consensus once the public had had the opportunity to reflect on the concepts and ideas initially presented. The goal statements were then revised through the review process with the Task Force, the Planning and Environmental Commission and Town Council and now represent policy guidelines in the review process for new development proposals. These goal statements should be used in conjunction with the adopted Land Use Plan map, in the evaluation of any development proposal. The goal statements which are reflected in the design of the proposed Plan are as follows: 1. General Growth /Development 1.1 Vail should continue to grow in a controlled environment, maintaining a balance between residential, commercial and recreational uses to serve both the visitor and the permanent resident. Town of Vail Page 15 1/5/2016 1.2 The quality of the environment including air, water and other natural resources should be protected as the Town grows. 1.3 The quality of development should be maintained and upgraded whenever possible. 1.13 Vail recognizes its stream tract as being a desirable land feature as well as its potential for public use. 3. Commercial 3.1 The hotel bed base should be preserved and use more efficiently. 3.2 The Village and Lionshead areas the best location for hotels to serve the future needs of destination skiers. 3.3 Hotels are important to the continued success of the Town of Vail, therefore conversion to condominiums should be discouraged. 3.4 Commercial growth should be concentrated in existing commercial areas to accommodate both local and visitor needs. 4. Village Core/ Lionshead 4.1 Future commercial development should continue to occur primarily in existing commercial areas. Future commercial development in the Core areas needs to be carefully controlled to facilitate access and delivery. 4.2 Increased density in the Core areas is acceptable so long as the existing character of each area is preserved through implementation of the Urban Design Guide Plan and the Vail Village Master Plan. 4.4 The connection between the Village Core and Lionshead should be enhanced through: a. Installation of a new type of people mover. b. Improving the pedestrian system with a creatively designed connection, oriented toward a nature walk, alpine garden, and/or sculpture plaza. c. New development should be controlled to limit commercial uses. 5. Residential 5.1 Additional residential growth should continue to occur primarily in existing, platted areas and as appropriate in new areas where high hazards do not exist. 5.2 Quality time share units should be accommodated to help keep occupancy rates up. Town of Vail Page 16 1/5/2016 5.3 Affordable employee housing should be made available through private efforts, assisted by limited incentives, provided by the Town of Vail, with appropriate restrictions. 5.4 Residential growth should keep pace with the market place demands for a full range of housing types. 5.5 The existing employee housing base should be preserved and upgraded. Additional employee housing needs should be accommodated at varied sites throughout the community. VII. CRITERIA Amendments to the Lionshead Redevelopment Master Plan require a public hearing review process as outlined in Section 12-3-6 of the Town Code. If approved, amendments are adopted by the passage of a resolution by the Vail Town Council. According to the Lionshead Redevelopment Master Plan, amendments to the Master Plan must address the following review criteria: How have conditions changed since the plan was adopted? The Lionshead Redevelopment Plan was first adopted in 1998. Since its original adoption, the Plan has been amended several times. To date, the Plan has served the community well as more than twenty redevelopment projects have been completed within the Lionshead Study Area since 1998. As a result of these redevelopment projects, the community and property owners within Lionshead have been progressing incrementally towards achieving the six development objectives prescribed within the Plan. Undoubtedly, the Plan has been a success. A number of conditions affecting the community and those properties governed by the Lionshead Redevelopment Master Plan have changed since the Plan's adoption in 1998. Those conditions include: • A dramatic rise in real estate value has occurred. • The local, regional, national and global economies were impacted by the Great Recession. • The Vail community experienced a more than $2.51B town -wide redevelopment and renaissance. • The Vail Valley Medical Center adopted a master facilities plan and is currently underway with a +/- $200M redevelopment project. • A land exchange affecting the boundary lines and site area configurations of the Vail Valley Medical Center and Evergreen Lodge has been initiated. • A need to complete South Frontage Road traffic circulation improvements in the immediate vicinity of the Evergreen Lodge, Vail Valley Medical Center Campus and the Town of Vail Municipal site has been identified. Town of Vail Page 17 1/5/2016 • The effectiveness and relevancy of the economic incentives identified nearly twenty years ago and subsequently adopted in the 1998 Lionshead Redevelopment Master Plan have changed (i.e. grfa/dwelling unit per acre ratio) • Vail's annual summer and winter guest visitation has grown to more than 1.2M guests in the summer and 1.7M skier visits in the winter, respectively. • Real estate buyer preferences and expectations have evolved and changed since 1998. • The advent of VRBO and AirBnB along with other aspects of the new and evolving sharing economy has altered the face of the short-term accommodations market. How is the plan in error? The plan, as adopted, and as it governs the redevelopment of the Evergreen Lodge, is not in error. The demonstration of plan error, however, is not a requirement of a master plan amendment review and approval process. Instead, it is but one of three possible reasons for approving a master plan amendment. How would an addition, deletion, or change to the plan be in concert with the plan in general? The 1998 Lionshead Redevelopment Master Plan identifies six fundamental design or development objectives. Each of the objectives is aimed at addressing and responding positively to certain shortcomings of the existing conditions of the physical and built environment within the Lionshead area. Upon adoption of the master plan, procedures were put in place to allow for future amendments to occur to the Plan throughout its useful lifetime. To date, a number of amendments have been approved and adopted. In each instance, the amendments did not fundamentally change or alter the six development objectives originally adopted with the Plan. Instead, the amendments served to further ensure that each of the objectives would be achieved. The additions, deletions, and changes proposed to the Chapter 5, Detailed Plan Recommendations, of the Lionshead Redevelopment Master Plan for the Evergreen Lodge are in concert with the Plan and its development objectives. For instance, the following list of detailed plan recommendations demonstrates the how the Plan remains in concert with the development objectives: • 128 accommodation units are being preserved on the Evergreen Lodge site. • Improvements are recommended for South Frontage Road traffic circulation. • On site loading and delivery is being provided within the future structure and off site delivery truck maneuvering will be eliminated. • A north/south pedestrian connection between West Meadow Drive and the South Frontage Road will be accommodated. • Improvements and enhancements to the Middle Creek stream corridor and riparian areas are being preserved. Town of Vail Page 18 1/5/2016 • The redevelopment of the existing Evergreen Lodge shall comply with the adopted development standards and design guidelines established for Lionshead. VIII. PLANNING AND ENVIRONMENTAL COMMISSION RECOMMENDATION The Town of Vail Planning and Environmental Commission forwards a recommendation of approval, as presented, of the proposed amendments to the Lionshead Redevelopment Master Plan, pursuant to Section 2.8, Adoption and Amendment of the Master Plan, Lionshead Redevelopment Master Plan, to amend the Detailed Plan Recommendations for the Evergreen Lodge at Vail, located at 250 South Frontage Road West/Lot 2W, Block 1, Vail Lionshead Filing 2, and setting forth details in regard thereto. The recommendation of approval is based upon the Commission's review of the proposed amendments, as amended over the course of the public hearing process and the finding that the applicant has demonstrated to the satisfaction of the Commission that conditions within the Lionshead Study Area have changed since the original adoption of the master plan and that the requested additions, deletions, or changes to the plan are in concert with the adopted development objectives, outlined in Section VII of the memorandum dated October 26, 2015. Should the Town Council choose to approve the proposed amendments, as recommended, the Commission recommends that the Town Council place the following condition upon the approval: 1. The master plan amendment (PEC140044) shall become effective upon the date that a proposed resubdivision application for the land exchange between the Evergreen Lodge at Vail and the Vail Valley Medical Center is reviewed and approved by the Town of Vail and the resubdivision map is duly recorded by the applicant or their agent at the Office of the Clerk and Recorder of Eagle County, Colorado. This conditional approval shall expire on December 31, 2020 (expiration date) unless the resubdivision map is recorded as required prior to the expiration date. Town of Vail Page 19 1/5/2016 RESOLUTION NO. 38 Series of 2015 A RESOLUTION AMENDING THE LIONSHEAD REDEVELOPMENT MASTER P LAN TO AMEND THE DETAILED PLAN RECOMMENDATIONS FOR FUTURE DEVELOPMENT ON THE EVERGREEN LODGE AT VAI L DEVELOPMENT SITE, AS PRESCRIBED IN CHAPTER 5 OF THE LIONSHEAD REDEVELOPMENT MASTER PLAN, AND SETTING FORTH DETAILS IN REGARD THERETO. WHEREAS, on December 15, 1998, the Vail Town Council (the "Town Council") adopted the Lionshead Redevelopment Master Plan (the "Master Plan"); and WHEREAS, the Master Plan was initiated by the Town of Vail to encourage redevelopment and new development initiatives within the Lionshead Study Area; and WHEREAS, Section 2.8 of Master Plan outlines a procedure for amending the Master Plan; and WHEREAS, pursuant to Section 2.8 of the Master Plan, the applicant Evergreen Lodge at Vail, represented by Mauriello Planning Group, has proposed an amendment to the Master Plan; and WHEREAS, the Town of Vail Planning & Environmental Commission has held four public hearings on the proposed amendment a n d on October 26, 2015, forwarded a recommendation of approval of the amendment to the Town Council; and WHEREAS, the purpose of this amendment isto amend the detailed plan recommendations for future development on the Evergreen Lodge at Vail development site, as prescribed in Chapter 5, Detailed Plan Recommendations, Lionshead Redevelopment Master Plan; and WHEREAS, the Town Council finds that the proposed amendment improves and enhances the effectiveness of the Master Plan and positively affects the goals, objectives, and policies prescribed in the Master Plan by: 1. Clearly identifying and articulating the desired outcomes of a future redevelopment of the Evergreen Lodge at Vail property, 2. Removing language from the Master Plan which is no longer relevant or applicable 3. Responding to changes in conditions as a result of the land exchange with Vail Valley Medical Center, and 4. Establishing predictability within the review process by providing detailed site specific recommendations for redevelopment of the Evergreen Lodge at Vail site. 1/5/2016 NOW, THEREFORE, BE IT RESOLVED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO: 1. The V a i I Town Council of the Town of Vail hereby amends the Lionshead Redevelopment Master Plan as follows: The amendments to the text of the Lionshead Redevelopment Master Plan are indicated in bold italics (additions) and str keth -ough italics (de m). 5.19 Evergreen Lodge at Vail The Evergreen Lodge at Vail is located directly east of the Middle Creek Stream Tract and is bordered to the north by the South Frontage Road and to the south east by the Vail Valley Medical Center., and to the east by the West Star Rank nffiGe building. The lot area is approximately 104,108 114,337 square feet in size or roughly 2.39 2.625 acres. Since the original inclusion in the Lionshead Redevelopment Master Plan, a portion of the Evergreen Lodge parcel, adjacent to the existing WMC parking garage, was sold in 2014 to the Vail Valley Medical Center (WMC). Additionally, in 2015, the Evergreen Lodge and the Vail Valley Medical Center, entered into an agreement to exchange land that resulted in the Evergreen Lodge acquiring a portion of the WMC property south of the Evergreen Lodge and WMC acquiring a portion of Evergreen Lodge land east of the Lodge. (See figure 1) The agreement was reached based on the conclusion of a two-day charrette between WMC, Town of Vail, and the Evergreen Lodge representatives, which was conducted in December of 2014 where the parties developed an overall conceptual redevelopment scheme benefiting all parties. The resulting land area for the Evergreen Lodge is approximately 2.50 acres after the land trade. Physical improvements that currently exist on the site are a nine - story tall hotel/condominium structure containing 19 dwelling units and 128 accommodation units with an adjoining two-story tall hotel amenities wing containing a restaurant, cocktail lounge and bar, meeting rooms and conference facilities, twe-one below -grade structured parking garage containing 52 parking spaces, and paved surface parking comprised of 85 parking spaces. The nine -story tall structure has a predominant east -west orientation along the southerly edge of the site while the facilities wing has a north -south orientation along the westerly edge of the site. Vehicle access to the site is provided by two existing curb cuts along the South Frontage Road. No dedicated loading and delivery berths currently exist on the site. Delivery vehicles often are required to maneuver onto the site by backing in from the South Frontage Road. The eastern parking garage is utilized by the Vail Valley MediGal Gente entry/exit with the West Star Ronk nffine building_. ding Opportunities for future improvements and upgrades include: • Elimination of surface parking and creation of more underground parking; • Enclosed Loading and Delivery; • Architectural enhancements consistent with the Lionshead Architectural Design Guidelines; • Improved exterior lighting; • Coordinated vehicular access and implementation of the Vail Streetscape Master Plan recommendations; • Creek improvements to improve health and access by the public; • Improved streetscape and landscaping along the South Frontage Road; 1/5/2016 Improved pedestrian circulation along the South Frontage Road and connection to West Meadow Drive; and Upgraded and expanded hotel accommodations and amenities, and inclusion of a flat floor conference area. 5.19.1 Pedestrian Access Pedestrian access should be upgraded to provide a safe and attractive pedestrian connection from the South Frontage Road, through the Evergreen Lodge development site and/or the adjacent tracts of land owned by the Town of Vail and the Eagle River Water and Sanitation District, to West Meadow Drive and with a continuous pedestrian/bicycle path along the South Frontage Road, as dep*Gted „n near, T he consistent with the Town's proposed plans for a roundabout along the frontage of the Evergreen Lodge property (see figure 2) A gravel path connecting the South Frontage Road to the paved pedestrian path located on the east side of the Dobson Ice Arena presently exists along the south side of the property. This path, while functional, receives little, if any, regular maintenance and includes a railroad tie set of stairs that is unsafe and in disrepair. There are currently no pedestrian improvements located along the South Frontage Road along the Evergreen Lodge frontage. Though no improvements exist, a fair number of pedestrians use the southerly edge of the South Frontage Road when entering or exiting the site or while traveling past the property. In order to improve pedestrian access and safety, it is recommended that future redevelopment of the site includes the construction of a continuous pedestrian/bicycle path along the South Frontage Road and that the existing gravel path along the southerly edge of the site be improved and regularly maintained. Said impr„vomonts .,.,a„ neGessitate the need for pedestrian aeoessreasements threugh the Site. Based on the results of the two-day charrette, the land trade provides an opportunity to create a pedestrian walkway from the South Frontage Road to West Meadow Drive along ;he new sharedproperty line betweenthe sRru^*�-^^ both properties as generally depicted in Figure 2 (see figure 2). Conceptually, the new walkway could benefit users of both the WMC and the Evergreen Lodge properties while also allowing for access by the public. It may be necessary to utilize the Town owned Lot 10 to accomplish the desired pedestrian connection from South Frontage Road to West Meadow Drive, a desired public improvement. 5.19.2 South Frontage Road Improvements and Vehicular Access The site is currently accessed by vehicles from the South Frontage Road frGm with two, full movement—,two-w,ay access points. The current location of these access points relative to the existing access points for the `VestSta; US Bank Building, Vail Valley Medical Center parking structure, Town of Vail Municipal Buildings, and potential future access points to the Vail Valley Medical Center and Vail International Building results in undesirable traffic flow and turning movements creating traffic safety, ani capacity, and level of service concerns. In keeping with Policy Objective 2.3.4, Improved Access and Circulation, of the Plan, opportunities for public transportation and vehicular circulation improvements should be explored in conjunction with any future redevelopment of the site. Possible opportunities for improvements may include, an improved mass transit stop, relocated/reduced/shared points of entry/exiting, restricted access points, acceleration/ deceleration lanes, greater sight distances, dedicated turning lanes and landscaped medians, and the evaluation and possible implementation of an intersection solution, such as a roundabout. If constructed, a full, two lane roundabout could be located along the frontage of the Evergreen and Town of Vail Municipal site that 1/5/2016 takes into account the additional through -traffic needs of the community but also the future redevelopment of the Town's municipal site, WMC, and the Evergreen Lodge properties. Additional study of the roundabout design is necessary. As envisioned, the roundabout and roadway improvements would allow for a primary right in, right out vehicular access and a separate right in, right out service vehicle access to the Evergreen Lodge property. The proposed roundabout as envisioned encroaches into the Evergreen Lodge property and the Town's municipal site which impacts the future development of the properties. in an effort to improve the pedestrian environment along West Meadow Drive and further reduce the total number of vehicle trips on West Meadow Drive, vehicular access to the Evergreen Lodge from West Meadow Drive shall be prohibited. 5.19.3 Preservation of Existing Accommodation Units The Evergreen Lodge presently contains 128 short term accommodation units. In addition, the Evergreen Lodge also contains a restaurant, cocktail lounge and bar and meeting rooms incidental to the operation of the Lodge. Originally built in 1974, the existing accommodation units and hotel amenities are old and outdated. The Lodge was developed to the standards desired more than four decades ago and likely no longer provides guests with accommodations meeting more modern standards and expectations. Given the importance and need for short-term accommodations to the vitality and success of the community, any future redevelopment of the site shall ensure, at a minimum, the preservation or replacement of the number of 128 short-term accommodation units on the site, in keeping with the live bed policy in Section 4.13. The preservation of short term accommodations should focus on maintaining the number of accommodation units. existing hotel beds and the amei int of gross residential square feetage on the site as well as requiring the preservatien of 128 annommedation units. With this in mind the quality of the existing anrommedation i snit reeM GeUld be upgraded and the reerns reGenfigured tO Greate multi room suites. ii -I --n e ii nes ttaR wever, s}ni ild the nmol intef grecs residential fleer area devoted tie annnmmedation units he re`Ji inert While the development trend in Vail since the late 1990's has been to focus on high-end, luxury accommodation units utilizing more floor area per unit, an opportunity exists to create high quality accommodation units that are smaller in size, and potentially _greater in number, and likely to be more affordable, yet achieve the goals of preserving the existing number of accommodation units, maintaining live beds on the site, and increasing the revenues and vitality of the Town. in�Opportunities for increasing the number of accommodation units beyond the existing 128 units already on-site should be evaluated during the development review process. For example, the construction of "attached accommodation units", as defined in the %ening Reg dations or the provision of a rental management program, could significantly increase the availability of short-term rental opportunities within the building. through redevelopment. 5.19.4 Impacts on Middle Creek Stream Tract The Middle Creek Stream Tract lies to the west of the Evergreen Lodge. The Tract is made up of two parcels. One owned by the Town of Vail and the other by the Eagle River Water and Sanitation District. The Tract is heavily vegetated with mal substantial al deciduous trees, a significant lower layer of riparian underbrush and also includes a pedestrian path and a pedestrian bridge. Given the importance of water quality, it is imperative that any future development on the Evergreen Lodge site 1/5/2016 does not negatively impact or encroach upon the existing riparian corridor of Middle Creek and that it comply with any stream health initiatives, including any amendments to the watercourse setback requirements that may be adopted town wide. Although the site borders the Middle Creek Stream Tract, there is no significant amount of quality vegetation on the site and the parcel lies out of the 100 -year flood plain. As currently configured, opportunities exist to better recognize the benefits of creek side development and to improve and enhance the riparian corridor to address the overall health of the Creek. For purposes of this master plan recommendation, the riparian corridor shall be defined as the Middle Creek Stream Tract. While the natural riparian corridor of Middle Creek shall needs to remain protected and preserved, the physical and visual relationships and references between adjacent development and the strearn traGtTract should be strengthened. Careful consideration should be taken when approving any application for development adjacent to Middle Creek. Any future development application for the redevelopment of the Evergreen Lodge site shall be accompanied by an environmental impact report consistent with the requirements prescribed in Chapter 12, Environmental Impact Reports, Title 12, Zoning Regulations, Vail Town Code. An opportunity exists to create a significant connection between the Evergreen Lodge and Middle Creek. Any use of Middle Creek for aesthetic or recreational purposes, however, should be subordinate to the preservation of the natural riparian corridor and its inherent natural character. The Middle Creek Stream Tract may provides an opportunity for the construction of a recreational path connecting the South Frontage Road and uses on the Evergreen Lodge property to the existing pedestrian paths at the Dobson Ice Arena providing a strong pedestrian connection to West Meadow Drive. 5.19.5 Relationship to the Vail Valley Medical Center and the Vail International Perhaps the most critical functional relationship is the need to coordinate any future development on the Evergreen Lodge site with the Vail Valley Medical Center. For example, every effort should be taken to ensure that future ire deyelenment on the Evergreen Ledge site ales net npr d de the Vail Valley Medinel ('enter from reGenfiguring the design of the mediGal Genter to eliminate vehiGular aGGess off of West Meadow DFi` a and relonate the enness to the South Frontage Read Add+tieeal opportunities for coordination may include, shared service and delivery facilities, grading and site improvements, shared parking, and pedestrian pathway connections. and land eXGhanges. Both parties have taken steps to ensure the properties can be redeveloped in a more coordinated manner by executing the land exchange. The land exchange provides better access length, frontage, and redevelopment opportunities to the Vail Valley Medical Center by securing additional South Frontage Road access and providing , leGation fo , ossihle future emerger Gy heli ad providing dire Gt Gce s to medical f Gilifiec on campu-s-and providing more flexibility in the design of a possible East Wing of the WMC. The exchange of land affords the Evergreen ► edge and miner an opportunity to accommodate an important pedestrian connection from the South Frontage Road to West Meadow Drive, thereby strengthening the pedestrian connection into Lionshead and Vail Village. The land exchange also allows for improved vehicular access by providing a reasonable location for a roundabout located in front of and on the Evergreen Lodge property improving access to both properties. This pedestrian connection could potentially utilize a one-story deck that could cover surface parking on the WMC campus. While a deck provides covered parking screened from public view, it also introduces a landscape element and plaza benefiting the views and use by patrons from Evergreen 1/5/2016 Lodge, and-WMC, and the community at large. In order for a connection and landscape enhancement to be successful, it,,t be it may require that it to be developed with reduced or zero setbacks between the properties and may require stairs and elevator access on or adjacent to Lot 10. its recneGtiye properties may need to nreWde guarantees and/or temporary improvements suGh as landscape buffers and pedestrian paths to mitigate temporary and interim development imparts The Vail International is located across from to the Evergreen Lodqe site on the west side of the Middle Creek Stream Tract. Buildinq bulk, mass and scale on the Evergreen Lodqe site is affected by the need for the emergency helipad located on the Vail Valley Medical Center property and the requirement that any future building on the exchange parcel steps down towards West Meadow Drive to create an appropriate pedestrian scale. These two design considerations result in the greatest building bulk, mass and scale being located in the northwest corner of the Evergreen Lodge development site. During the development review process, the DRB and the PEC shall pay special attention to the western facade of any new or redeveloped structure to ensure it is appropriately articulated to provide visual interest, shadow lines and avoids large unbroken wall planes. For the portion of the development alona the Middle Creek Stream Tract buildin facades facing west towards the stream corridor should step back from the Creek to ensure adequate sunlight reaches the ground and there should be a clear separation. most likely a native landscape buffer. between the public and the rivate spaces. 1/5/2016 5.19.6 Service and Delivery Service and delivery functions for the hotel are currently accommodated on grade from the westerly entrance to the property. Service and delivery for the redeveloped Evergreen Lodge shall occur within the structures er and otherwise be hidden adequately screened from public view. Service and delivery truck turning maneuvering shall not negatively impact traffic flow on the South Frontage Road and a separate loading and service entry may be allowed in conjunction with the construction of a potential new roundabout in this location. With a realignment of parking areas. An additional level Of StFLIGWred parkiRg at the GurreRt FreRtage Read level would help te MiRimize the appareRt height ef the exiStiRg or future StFUGtures, f t surfQGe o��he ctnrU ire and hide coniine fi inn+innc holew gra Flo 5.19.7 Setbacks frorn the, South Frontage Geed Special consideration should be given to the setback of buildings from the South Frontage Road. Pursuant to the Lionshead Mixed Use -1 zone district setback standards, a minimum 10 -foot (10') setback is required. Given the relationship of the development site to the South Frontage Road, the need for adequate area for vehicular traffic circulation, the importance of a landscape area to visually screen the massing of the building, and the existence of a 30 -foot wide utility easement along the southerly edge of the South Frontage Road, the minimum required front setback for the Evergreen Lodge development site shall be thirty feet (30'). This increased setback requirement shall supersede the 10 -foot setback requirement prescribed in Section 12-7H-10, Setbacks, Vail Town Code. Based upon the coordinated efforts between the Evergreen Lodge and the Vail Valley Medical Center, opportunities exist for a covered parking deck and pedestrian access landscape plaza to be developed between the properties with the goal of screening surface parking and enhancing the visual quality of the area. If appropriately designed, a reduced or zero set back in these areas may be proposed for review during the development review process. Additionally, below grade improvements, including but not limited to, parking and vehicular circulation improvements may be developed within the required setbacks, if found to be consistent with the Town's development objectives. 5.19.8 Architectural Improvements and Building Heights The architectural design guidelines (Chapter 8) discuss several transition tools that can be used to adapt an existing building to the new character and architectural quality desired for Lionshead. Given the high visibility of the buildings on this site and the extent to which they influence the quality of the experience of passers-by, all future development on the site should be closely scrutinized for compliance with the applicable architectural design guidelines. That said, the Evergreen Lodge is located in a transitional area with VVMC, the Library, and Dobson Arena, which tend to have more modern or institutional architecture. The building will need to have a relationship to adjacent buildings and pedestrian corridors. With the addition of the land acquired from the Vail Valley Medical Center, the Evergreen Lodge has the opportunity to step building mass down towards West Meadow Drive in a 1/5/2016 north/south orientation. Building mass should step down from the South Frontage Road to the south boundary of the Evergreen Lodge property. The building on the land exchange parcel should step down to a maximum of four and five stories with complementary roof forms to achieve a pedestrian scale building, consistent with the west wing of the medical center (see figure 3), and subject to design review. The final building massing, scale and form shall be determined during the development review process. 5.19.9 Public Transit Stop A public transit stop is presently located east of the `^iia US Bank Building, across the street from the Town Municipal offices. Through the future redevelopment of the Evergreen Lodge and the Vail Valley Medical Center, an opportunity exists to potentially relocate the transit stop to a more optimal location. 1/5/2016 -�PMTY OW I' - Rreeaaed Tewn R—d. — .r.aw:� I f Town NYall gpaam drier AAI UA' ' . i' - M1lLM1 t.A Land Tn ded e. WhYC Lied Tri E rrE--L,d Lod.. ER D S—. T.—I LOTS A j r WEST M€AF)OWCIRIII Figure 1 ."-� -! -� Ropowd Tam Rwrdabou ! A A' Tewrd Yell Ser.an Tran ! f \ \\North 1 South Connection to Meadow Drive ERY/SO52raamT - � i A ! � -- - J��_� � �� �� �•rraC� ... _ -- -� _:--- yr�- r W...c M1l (vT F` !i LOTS i t 5 __.— f .✓y VaTry M1naf[Y Cmr3n L` ..' ! '� ! y - WEST MEADOW DRIV@- - [ , Figure 2 1/5/2016 SOUTH FRONTAGE WEST MEADOW ROAD DRIVE 819IX 8942' & Stories Evergreen Lodge Conceptual Building Height . SedewalK Evergreen Lodge Parch Trade Parcel .f Lo[ 10 Easement Setback mm Figure El 1/5/2016 2. Effective Date This Resolution shall become effective upon the date that the land exchange subdivision amendment ( the "resubdivision map") with the Vail Valley Medical Center is duly recorded at the Office of the Clerk and Recorder of Eagle County, Colorado. The condition approval of this Resolution shall expire on December 31, 2020 ( the "expiration date") unless the resubdivision map is recorded as required prior to the expiration date. INTRODUCED, READ, APPROVED AND ADOPTED this 5t" day of January, 2016. ATTEST: Patty McKenny, Town Clerk Dave Chapin, Mayor, Town of Vail 1/5/2016 The amendments proposed by the applicant and recommended by the Planning and Environmental Commission have been drafted and will be presented assuming the proposed land exchange has occurred. Town staff recommended that any motion by the Commission recommending approval or approval with modifications, of the requested master plan amendment contains a condition that said amendments are 1/5/2016 'r I ;k(I u Mauriello Planning Group January 2, 2016 Vail Town Council Town of Vail 75 South Frontage Road Vail, Colorado 81657 Re: Master Plan Amendment - Evergreen Lodge Property Dear Town Council Members: We appreciate the opportunity to work with you on the proposed amendments the Lionshead Redevelopment Master Plan intended to recognize the proposed trade of land with the Vail Valley Medical Center (VVMC). The trade of these parcels will result in significant benefits to VVMC allowing them to have more building height and allowing the helipad to be repositioned and lowered in height. While the Evergreen Lodge will enjoy a site that has better pedestrian relationship with West Meadow Drive, the site will be more encumbered with height restrictions generated by the impacts of the helipad and the stepping down of the building height as it approaches West Meadow Drive. The remaining three dimensional development envelope is therefore fairly constrained beyond what is allowed by the property today given that it is already zoned Lionshead Mixed Use -1. Staff has been trying to balance the general goals of the master plan, the input of neighbors, the recommendation from the Planning and Environmental Commission, and the goals of the applicant. The staff has done a great job in this balancing effort. In order to address the comments from the Vail International and recognize the findings of the preliminary sun shade analysis (a building of any height will shade portions of the creek in the morning hours regardless of setbacks), we would like to offer the following revised language for the new text added on page 6 of the resolution: "The Vail International Condominium Building is located across from to the Evergreen Lodge site on the west side of the Middle Creek Stream Tract. Building bulk, mass and scale on the Evergreen Lodge site is affected by the need for the emergency helipad located on the Vail Valley Medical Center property and the requirement that any future building on the exchange parcel steps down towards West Meadow Drive to create an appropriate pedestrian scale. These two design considerations result in the greatest building bulk, mass and scale being located in the northwest corner of the Evergreen Lodge development site. In consideration of the neighboring property owner, during the review of a development plan for the proper aevelep. eiit .,___,w p-aee...., the DRB and the PEC shall pay special attention to the western facade of any new or redeveloped structure to ensure it is appropriately articulated to provide visual interest, shadow lines and avoids large unbroken wall planes and which may include building stepbacks in appropriate locations based on the overall building design and scale. Mauriello Planning Group 1/5/2016 The applicant is in agreement with the other revisions proposed including those specific changes recommended by councilman Moffet. We believe that the language in the resolution as proposed is adequate to provide general policy and design direction to the bodies reviewing the development plan and trying to force additional requirements, such as additional setbacks, not generally applicable to the Town at large, will go too far beyond what is fair and equitable to similarly situated properties. The applicant hopes that you will vote on the resolution, with this proposed change, on January 5. Sincerely, �4" Dominic Mauriello, AICP Principal cc: George Ruther, AICP 2 1/5/2016 Wil International CONDOMINIUMS January 4, 2016 Honorable Mayor Dave Chapin & Town Council Town of Vail 75 S. Frontage Road West Vail CO 81657 Re: Evergreen Lodge at Vail Master Plan Amendment Dear Mayor Chapin: On behalf of the fifty-four owners within Vail International I would like to extend our appreciation to the Vail Town Council for granting us additional time to work with the town staff and applicant on the proposed amendments to the Lionshead Redevelopment Master Plan ("LRMP"). We have been engaged in productive discussions with staff and the applicant since the hearing of December 15th and believe that there have been significant improvements to the proposed resolution. We support the additional language in Section 5.19.4 Impacts on Middle Creek Stream Tract and the added language in Section S.1 9.5 Relationship to the Vail Valley Medical Center and the Vail International Condominium Building. We do however have serious concerns that this language is somewhat loose and ambiguous when compared to other portions of the LRMP and respectfully request that a few words of prescriptive language be added to the resolution to ensure clarity of intent. The LMU-2 Zoning was intended to incentivize redevelopment of the Lionshead area by adding significant amounts of density and building bulk and mass. At the increased size of 2.5 acres the Evergreen Lodge will be allowed to redevelop at a maximum of 272, 250 square feet of GRFA within 87 dwelling units. The maximum height allowance is 82 feet with a 71 -foot average. The GRFA maximum does not include the additional square footage allowed for lodge rooms, meeting space, bar and restaurant space, and common areas. The potential building bulk and mass is very significant. There are factors in the LRMP that will influence the ultimate building design, such as WMC helipad clear zone requirements and the prescriptive four to five floor height limitation placed on the exchange parcel. These master plan requirements will have the effect of directing significant building mass and height towards the Middle Creek stream corridor and the Vail International. 300 East Lionshead Circle • Vail, CO 81657 • (970) 476-5200 • (800) 622-3477 toll-free • (970) 476-4427 fax web: www.vailintemational.com • email: Snowden@vailinternational.com 1/5/2016 Vail International CCJ N D0N1INfL Nt While Vail International enjoys close proximity to Lionshead there is certainly a different character to the Vail International location than is found in the Lionshead core area. Many of our owners purchased here to enjoy the relative quiet and seclusion of the location. The adjacency of the stream corridor is a tremendous feature of the property. The potential of an 82 -foot tall building wall with no significant step back required until 62 feet in height is a very significant impact to that character. The light and shade impacts of the building height will be a detriment to Vail International. While we understand the right to redevelop the Evergreen Lodge property we also believe it is reasonable to address those impacts by creating some building step back along Middle Creek that will open up more light and air space between the Evergreen and Vail International. This may be accomplished by amending the last sentence of Section 5.19.5 to read as follows (suggested revision shown in red text): For the portion of the development along the Middle Creek Stream Tract building facades facing west towards the stream corridor should step back a minimum of 12' at the third floor level from the Creek to ensure adequate sunlight reaches the ground and there should be a clear separation, most likely a native landscape buffer, between the public and the private spaces. This prescriptive language is similar to the step back provisions found in other portions of the LRMP. Vail International feels that this specific guidance provides a balance to the impacts directed towards this portion of the site that are created by other prescriptive aspects of the proposed amendment, as described earlier in this letter. This type of step back would support the statement made is Section 8.4.2.3 of the LRMP that states: new and redeveloped buildings in Lionshead should avoid "turning their backs" on other buildings or important pedestrian corridors". We believe that this additional language will provide a significant benefit to the stream corridor and offset impacts to Vail International while still allowing creative design solutions that will allow the Evergreen to optimize the redevelopment potential of the property. We appreciate the time and the effort that the town invests in the review of development and redevelopment proposals and thank you for your consideration of this request. Vail InterrWtional Condominium Association By:_ J Weston, President 300 Eas?Lionshead Circle • Vail, CO 81657 • (970) 476-5200 • (800) 622-3477 toll-free • (970) 476-4427 fax web: www.vailintemational.com • email: Snowden@vailintemational.com 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: First reading of Ordinance No. 1, Series of 2016, An Ordinance Amending the Definition of Short -Term Rental in the Vail Town Code PRESENTER(S): Matt Mire, Town Attorney ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny Ordinance No. 1, Series of 2016, upon first reading. BACKGROUND: Section 12-2-2 of the Vail Town Code defines a short-term rental as a rental for a period of time not exceeding 31 days. Section 4-1-2 of the Vail Town Code defines short-term rental as a rental for a period of time not exceeding 30 days. The Town Council desires to amend Section 12-2-2 to ensure consistency in the Vail Town Code. STAFF RECOMMENDATION: Approve, approve with modifications, or deny Ordinance No. 1, Series of 2016, upon first reading. ATTACHMENTS: Ordinance No. I Series of 2016 1/5/2016 ORDINANCE NO. 1 SERIES 2016 AN ORDINANCE AMENDING THE DEFINITION OF SHORT-TERM RENTAL IN THE VAIL TOWN CODE WHEREAS, Section 12-2-2 of the Vail Town Code defines a short-term rental as a rental for a period of time not exceeding 31 days; WHEREAS, Section 4-1-2 of the Vail Town Code defines short-term rental as a rental for a period of time not exceeding 30 days; and WHEREAS, the Town Council desires to amend Section 12-2-2 to ensure consistency in the Vail Town Code. NOW, THEREFORE, BE IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO, THAT: Section 1. Section 12-2-2 of the Vail Town Code is hereby amended as follows: SHORT TERM RENTAL: Shall be deemed to be a rental for a period not exceeding thirtyons (30) days. Section 2. Severability. If any part, section, subsection, sentence, clause or phrase of this ordinance is for any reason held to be invalid, such decision shall not effect the validity of the remaining portions of this ordinance; and the Town Council hereby declares it would have passed this ordinance, and each part, section, subsection, sentence, clause or phrase thereof, regardless of the fact that any one or more parts, sections, subsections, sentences, clauses or phrases be declared invalid. Section 3. Retroactivity. The amendment of any provision of the Town Code as provided in this ordinance shall not affect any right which has accrued, any duty imposed, any violation that occurred prior to the effective date hereof, any prosecution commenced, nor any other action or proceeding as commenced under or by virtue of the provision amended. The amendment of any provision hereby shall not revive any provision or any ordinance previously repealed or superseded unless expressly stated herein. Section 4. Repeal. All bylaws, orders, resolutions and ordinances, or parts thereof, inconsistent herewith are repealed to the extent only of such inconsistency. This repealer shall not be construed to revise any bylaw, order, resolution or ordinance, or part thereof, theretofore repealed. INTRODUCED, READ ON FIRST READING, APPROVED, AND ORDERED PUBLISHED ONCE IN FULL ON FIRST READING this 5th day of January, 2016 and a public hearing for second reading of this Ordinance is set for the 19th day of January, 2016, in the Council Chambers of the Vail Municipal Building, Vail, Colorado. Dave Chapin, Mayor ATTEST: Patty McKenny, Town Clerk Ordinance No. 1, Series of 2016 1/5/2016 Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: First reading of Ordinance No. 2, Series of 2016. An Ordinance Amending Title 12, Zoning Regulations, Vail Town Code, Pursuant to Section 12-3-7, Amendment, Vail Town Code, to allow for Religious Institutions as a Conditional Use in all zone districts except the Heavy Service (HS) District; Outdoor Recreation (OR); Natural Area Preservation (NAP); Hillside Residential (HR); Single Family Residential (SFR); Two -Family Residential (R) ; Two - Family Primary/Secondary (PS); Housing (H); Vail Village Townhomes (VVT); and Arterial Business (ABD); amending the definition of Religious Institutions, and setting forth details in regard thereto. PRESENTER(S): Chris Neubecker, Planning Manager ACTION REQUESTED OF COUNCIL: Approve, approve with modifications, or deny Ordinance No. 2, Series of 2016, upon first reading. BACKGROUND: In September 2015, the Community Development Department was approached by a citizen concerning the lack of zoning districts that allow Religious Institutions. After considering the application, and also considering applicable federal laws, the Department determined that this issue extends beyond the commercial zone districts and needed greater consideration. This ordinance will also bring the Town's Zoning Regulations into greater conformance with the Religious Land Use and Institutionalized Persons Act (RLUIPA). STAFF RECOMMENDATION: Approve or approve with modifications, Ordinance No. 2, Series of 2016, upon first reading. ATTACHMENTS: Memorandum Ordinance No. 2 Series of 2016 Religious Institutions First Reading Ordinance No 2 Series of 2016 Religious Institutions First Reading 1/5/2016 rowN ofvain Memorandum To: Vail Town Council From Community Development Department Date: January 5, 2016 Subject: Ordinance No. 2, Series of 2016, an Ordinance making changes to the Vail Town Code relating to the location of Religious Institutions, and making changes to the definition of Religious Institutions. I. SUMMARY A request for an amendment to the prescribed regulations of the Zoning Regulations pursuant to Section 12-3-7, Amendment, Vail Town Code, to allow for Religious Institutions as a Conditional Use in all zone districts except the Heavy Service (HS) District; Outdoor Recreation (OR); Natural Area Preservation (NAP); Hillside Residential (HR); Single Family Residential (SFR); Two -Family Residential (R) ; Two -Family Primary/Secondary (PS); Housing (H); Vail Village Townhomes (VVT); and Arterial Business (ABD); amending the definition of Religious Institutions, and setting forth details in regard thereto. (PEC150030) This ordinance would amend the Vail Town Code to allow Religious Institutions (churches, chapels, cathedrals, temples and similar designations) in the same zone districts where similar non -religious assembly uses (such as meeting rooms, conference facilities and private clubs) are currently allowed. The proposed ordinance supports the Town Council Action Plan goal to develop a balanced community and to "Expand our community infrastructure as the foundation of the town's success with particular emphasis on an abundance of recreational, cultural and educational opportunities while building capacity for future leaders." II. BACKGROUND In September 2015, the Community Development Department was approached by a citizen concerning the lack of zoning districts that allow Religious Institutions. The citizen's original application to amend the Town Code was for allowing Religious Institutions in all commercial zone districts. After considering the application, and also considering applicable federal laws, the Department determined that this issue extends beyond the commercial zone districts and needed greater consideration. 1/5/2016 The purposes of this ordinance are to: • Provide more zone districts in town where Religious Institutions may be located • Expand community infrastructure that supports cultural opportunities • Clarify the definition of Religious Institutions to include the incidental and secondary uses that customarily accompany Religious Institutions • Bring the Town's Zoning Regulations into greater conformance with the Religious Land Use and Institutionalized Persons Act (RLUIPA). This federal law prohibits governments from enacting zoning legislation that would create a substantial burden on the right to religious exercise of a person or institution, unless the government can demonstrate that the law is furthering a compelling government interest. The law prohibits zoning regulations that are more onerous on Religious Institutions than similar non -religious uses (such as meeting rooms, convention facilities and other assembly uses). The Planning and Environmental Commission held public hearings on this item on November 9 and December 14, 2015. On December 14, 2015 the Planning and Environmental Commission made a recommendation to the Vail Town Council for approval of the attached ordinance. The Community Development Department is in support of this recommendation to the Vail Town Council. III. RECOMMENDATION The Planning and Environmental Commission recommends that the Town Council approve Ordinance No. 2, Series of 2016 upon first reading. Town of Vail Page 2 1/5/2016 ORDINANCE NO. 2 Series of 2016 AN ORDINANCE AMENDING TITLE 12, ZONING REGULATIONS, VAIL TOWN CODE, PURSUANT TO SECTION 12-3-7, AMENDMENT, VAIL TOWN CODE, TO ALLOW FOR A ZONING CODE TEXT AMENDMENT TO ALLOW FOR RELIGIOUS INSTITUTIONS AS A CONDITIONAL USE IN ALL ZONE DISTRICTS EXCEPT THE FOLLOWING DISTRICTS: HEAVY SERVICE (HS); OUTDOOR RECREATION (OR); NATURAL AREA PRESERVATION (NAP); HILLSIDE RESIDENTIAL (HR); SINGLE FAMILY RESIDENTIAL (SFR); TWO-FAMILY RESIDENTIAL (R); TWO-FAMILY PRIMARY/SECONDARY (PS); HOUSING (H); VAIL VILLAGE TOWNHOMES (VVT); AND ARTERIAL BUSINESS (ABD); AMENDING THE DEFINITION OF RELIGIOUS INSTITUTIONS, AND SETTING FORTH DETAILS IN REGARD THERETO. WHEREAS, the Town of Vail (the "Town"), in the County of Eagle and State of Colorado is a home rule municipal corporation duly organized and existing under the laws of the State of Colorado and the Town Charter (the "Charter"); WHEREAS, the members of the Town Council of the Town (the "Council") have been duly elected and qualified; WHEREAS, the Planning and Environmental Commission of the Town of Vail has held public hearings on the proposed amendments on November 9, 2015 and December 14, 2015 in accordance with the provisions of the Vail Town Code; WHEREAS, the Planning and Environmental Commission recommended approval of these amendments at its December 14, 2015 meeting, and has submitted its recommendation to the Council; WHEREAS, the Council finds that the proposed amendments are consistent with the applicable elements of the adopted goals, objectives and policies outlined in the Vail Comprehensive Plan and are compatible with the development objectives of the Town; WHEREAS, the Council finds that the proposed amendments further the general and specific purposes of Title 12, Zoning Regulations, Vail Town Code; WHEREAS, the Council finds that the proposed amendments promote the health, safety, morals, and general welfare of the Town and promote the coordinated and harmonious development of the Town in a manner that conserves and enhances its natural environment and its established character as a resort and residential community of the highest quality; 1/5/2016 NOW, THEREFORE, BE IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO, THAT: Section 1. Purpose The purpose of this ordinance is to establish additional zoning districts that will allow for Religious Institutions, thereby improving the ability to locate Religious Institutions in the Town and helping bring the Vail Town Code into greater compliance the Religious Land Use and Institutionalized Persons Act. Language added is shown in bold, and language proposed for removal is shown as strikethreug4. Section 2. Section 12-2-2 DEFINITIONS OF WORDS AND TERMS, Vail Town Code, is hereby amended as follows: RELIGIOUS INSTITUTION: A building or portion of a building used primarily for public worship by any number of congregations, along with those incidental and secondary uses such as a dwelling unit for members of the clergy or other spiritual leaders, office space, meeting rooms, and classrooms for religious education and community meeting space, but excluding buildings used exclusively for residential, educational, recreational or other uses not associated with public worship. Includes churches, chapels, cathedrals, temples, and similar designations. Section 3. Section 12-6E-3 CONDITIONAL USES is hereby amended as follows: 12-6E-3 CONDITIONAL USES: The following conditional uses shall be permitted in the RC district, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this tile: Religious institutions. Section 4. Section 12-6F-3 CONDITIONAL USES is hereby amended as follows: 12-6E-3 CONDITIONAL USES: The following conditional uses shall be permitted in the LDMF district, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this tile: Religious institutions. Section 5. Section 12-6G-3 CONDITIONAL USES is hereby amended as follows: 12-6G-3 CONDITIONAL USES: The following conditional uses shall be permitted in the MDMF district, subject to the issuance of a conditional use 1/5/2016 permit in accordance with the provisions of chapter 16 of this tile: Religious institutions. Section 6. Section 12-6H-3 CONDITIONAL USES is hereby amended as follows: 12-6H-3 CONDITIONAL USES: The following conditional uses shall be permitted in the HDMF district, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this tile: Religious institutions. Section 7. Section 12-7B-2 PERMITTED AND CONDITIONAL USES; BASEMENT OR GARDEN LEVEL is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted in basement or garden levels within a structure, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 8. Section 12-713-4 PERMITTED AND CONDITIONAL USES; SECOND FLOOR is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted on second floors, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 9. Section 12-7C-4 CONDITIONAL USES; GENERALLY is hereby amended as follows: The following conditional uses shall be permitted, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 10. Section 12-7D-2: CONDITIONAL USES is hereby amended as follows: The following conditional uses shall be permitted in the commercial core 3 district, subject to issuance of a conditional use permit in accord with the provisions of chapter 16 of this title: Religious institutions. 1/5/2016 Section 11. Section 12-7E-4: CONDITIONAL USES is hereby amended as follows: The following conditional uses shall be permitted in the CSC district, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 12. Section 12-7H-2: PERMITTED AND CONDITIONAL USES; BASEMENT OR GARDEN LEVEL is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted in basement or garden levels within a structure, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 13. Section 12-7H-3: PERMITTED AND CONDITIONAL USES; FIRST FLOOR OR STREET LEVEL is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted on the first floor or street level floor within a structure, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 14. Section 12-7H-4: PERMITTED AND CONDITIONAL USES; SECOND FLOOR AND ABOVE: is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted on second floors and higher above grade, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 15. Section 12-71-2: PERMITTED AND CONDITIONAL USES; BASEMENT OR GARDEN LEVEL: is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted in basement or garden levels within a structure, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. 1/5/2016 Section 16. Section 12-71-3: PERMITTED AND CONDITIONAL USES; FIRST FLOOR OR STREET LEVEL: is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted on the first floor or street level floor within a structure, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 17. Section 12-71-4: PERMITTED AND CONDITIONAL USES; SECOND FLOOR AND ABOVE: is hereby amended as follows: B. Conditional Uses: The following uses shall be permitted on second floors and higher above grade, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 18. Section 12-7J-3: CONDITIONAL USES: is hereby amended as follows: The following conditional uses shall be permitted in the PA -2 district, subject to issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. Section 19. Section 12-8D-3 CONDITIONAL USES: is hereby amended as follows: The following conditional uses shall be permitted in the ski base/recreation district, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious Institutions. Section 20. Section 12-8E-3 CONDITIONAL USES: is hereby amended as follows: The following conditional uses shall be permitted in the ski base/recreation 2 district, subject to the issuance of a conditional use permit in accordance with the provisions of chapter 16 of this title: Religious institutions. 1/5/2016 Section 21. If any part, section, subsection, sentence, clause or phrase of this ordinance is for any reason held to be invalid, such decision shall not affect the validity of the remaining portions of this ordinance; and the Town Council hereby declares it would have passed this ordinance, and each part, section, subsection, sentence, clause or phrase thereof, regardless of the fact that any one or more parts, sections, subsections, sentences, clauses or phrases be declared invalid. Section 22. The Town Council hereby finds, determines and declares that this ordinance is necessary and proper for the health, safety and welfare of the Town of Vail and the inhabitants thereof. Section 23. The amendment of any provision of the Town Code as provided in this ordinance shall not affect any right which has accrued, any duty imposed, any violation that occurred prior to the effective date hereof, any prosecution commenced, nor any other action or proceeding as commenced under or by virtue of the provision amended. The amendment of any provision hereby shall not revive any provision or any ordinance previously repealed or superseded unless expressly stated herein. Section 24. All bylaws, orders, resolutions and ordinances, or parts thereof, inconsistent herewith are repealed to the extent only of such inconsistency. This repealer shall not be construed to revise any bylaw, order, resolution or ordinance, or part thereof, theretofore repealed. INTRODUCED, READ ON FIRST READING, APPROVED, AND ORDERED PUBLISHED ONCE IN FULL ON FIRST READING this 5th day of January, 2016 and a public hearing for second reading of this Ordinance set for the 19th day of January, 2016, at 6:00 P.M. in the Council Chambers of the Vail Municipal Building, Vail, Colorado. Dave Chapin, Mayor ATTEST: Patty McKenny, Town Clerk 1/5/2016 Towx of vn' 1[1 VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: East Vail Fire Station Renovation, Budget and Design Update PRESENTER(S): Mark Novak, Fire Chief, John King, Facilities Manager ACTION REQUESTED OF COUNCIL: 1) Direct staff to include in the first Supplemental of 2016 , an increase in the project budget of $750,000 as well as a separate supplement of $435,000 for completion of two EHUs. 2) Authorize the Town Manager to enter into an agreement with Pierce Architects to complete the design work, resulting in complete construction documents. BACKGROUND: In August 2015 Council authorized the Town Manager to enter into an agreement with Pierce Architects to complete Conceptual and Schematic design for the for the renovation of the East Vail Fire Station. This phase of the design has been completed and has resulted in an updated budget for the project. To move forward with the project, Council will need to direct staff to supplement the project budget in the March 2016 Supplemental and direct the Town Manager to enter into an agreement with Pierce Architects to complete the design work, resulting in complete construction documents ATTACHMENTS: East Vail Fire Station Renovation 1/5/2016 rowN of vain Memorandum TO: Vail Town Council FROM: Mark Novak, Fire Chief; John King Facilities Manager DATE: January 5, 2016 SUBJECT: East Vail Fire Station Renovation Project I. BACKGROUND The purpose of this agenda item is to present an update on the East Vail Fire Station Renovation project and receive direction from the Town Council. Information to be presented includes: Status of Design Project Cost and Budget Update Project schedule Next steps for advancing the project forward The East Vail Fire Station was constructed in 1980 and is need of a renovation to address operational deficiencies, improvements to the mechanical systems and to improve the livability of the building. This project will also add a new EHU to the Town's pool of employee housing and renovate an existing EHU. In 2015 Council approved the expenditure of $150,000 for design. The 2016 Budget allocated $1.5 M for the project. The schematic design work has been completed which has allowed staff along with a contractor to develop a preliminary cost estimate for the project. The project is at a point in which direction is requested from Council regarding moving forward with the design process to develop complete construction documents and initiate the entitlement process. II. PROJECT COST AND BUDGET UPDATE The East Vail Fire Station (Station #1) project was shown in the five year capital plan in 2014 with a budget of $ 1.5 M. This budget was developed without the benefit of any programming or design work. Design work completed has included the input of Fire Department Staff, Public Works, neighbors, the DRB and Town Council. Note that DRB reviewed conceptual plans; formal submittal to DRB has not been initiated. Design work completed to date has allowed staff to develop a more informed budget. The initial estimate for construction costs was —1.76 M. Staff has taken an aggressive approach to value engineering which has resulted in estimated construction cost of 1/5/2016 $1.56 M (see table below as well as attachment describing value engineering applied to date). Construction costs during the last several years have increased approximately 20% per year; this factor is responsible for an increase in the cost projection of $300,000. The site survey, along with developing the use program has resulted in changes to the project. These changes include: o Addition of 1470 square feet of new building space. In the current configuration, fire apparatus are parked within inches of the back wall and front door. To address this issue it is necessary to increase the footprint of the building. This addition will help prevent accidents and improve the function of the space. The additional space will also provide additional storage space which will help extend the service life of firefighter personal protective equipment and will address current operational needs. The construction cost of the additional square footage is estimated at $300 per square foot, resulting in an increase of $441,000. o Create a separate entry for the EHUs. In the current configuration the existing EHU is accessed through the fire station. This will also enhance the livability of the EHUs by creating greater separation from the noise associated with fire station operations. o Abandoning the existing driveway and creating a new driveway on the opposite side of the building. This is will improve snow removal and provide better access to the parking area. The existing driveway was built partially on the adjacent property which is not owned by the TOV. o Creating an exterior enclosure for the emergency generator. This is necessary to improve fire department operations and increase serviceability of the generator. An important component of this project is the provision of two Employee Housing Units (EHUs). The Fire Station budget will cover the costs of the shell, rough in plumbing, electrical and heating of these units. The Town of Vail Buy Down Housing Fund will cover the costs of finishing these units. This approach was also used to fund the construction of two EHUs at the Vail Village Fire Station (Station 2). As is the current policy for the Station 2 EHUs, the new EHUs in East Vail will be placed in the Town's employee housing program. Employees who hold "critical" positions are given priority when leasing these units. Critical employees are: Police Officers, Firefighters, Dispatchers, Mechanics, Heavy Equipment Operators, Code Enforcement Officers, Public Information Officer and IT Specialists. Currently the EHUs at Station 2 are occupied by a dispatcher and a firefighter along with his family. 2 1/5/2016 a Fire Station #1 Budget Fire Station Housing: Two- 700 SF EHUs Contractor's Estimate (construction) 1562000 300000 Design Contingency 10% (construction) 156200 30000 Escalation 5% 78100 15000 Design Phase 1 and 2 26500 Design Phase 3,4,5,6 100000 27500 Construction Administration (Material testing, etc.) 40000 FFE 140000 IT 30000 Utility and Building Fees 50000 20000 Contingency 217280 39250 2490080 431750 Total 2015 Budget 150000 0 2016 Budget 1500000 0 1650000 0 Total Budget Difference 750080 431750 PROJECT SCHEDULE The development schedule milestones and durations are outlined below: TOV Entitlement Schematic Design Resident and Public Input Design Development Construction Documents (CD's) Construction Award by Town Council Construction VI. NEXT STEPS January. 2016 — March 2016 Complete January 2016 - --March 2016 January 2016—March 2016 April 2016 —May 2016 May 2016 June 2016 — November 2016 In order to meet the target start date of spring 2016, the entitlement process will need to be initiated in the very near future. A spring 2016 start is important so that key phases of the construction can be completed before winter 2016. Of particular importance is completing the apparatus bays during the warmer months as the fire apparatus require a conditioned parking space to be functional in the winter months. If this cannot be achieved, the fire apparatus and crews would need to be housed off site which would lead to increased response times and additional project expense. Council will have the opportunity to review the final budget at the time of construction contract award. 3 1/5/2016 Questions to be answered: 1) Does council want staff to include in the March 2016 budget supplemental an increase in the project budget of $ 750,000 to move this project forward as well as $435,000 for completion of two EHUs? 2) Does council authorize the Town Manager to enter into an agreement with Pierce Associates to continue design work, resulting in completed construction documents? If these questions are answered in the affirmative, staff would also initiate the project entitlement process. VII. STAFF RECOMMENDATION The Town Council is being asked to provide direction regarding the following: 1) Staff recommends that Staff be authorized to include in the March 2016 budget supplemental an increase in the project budget of $ 750,000 as well as a supplemental of $435,000 for completion of two EHUs. 2) Staff recommends that Council authorize the Town Manager to enter into an agreement with Pierce Associates to continue design work, resulting in completed construction documents? VIII. ATTACHMENTS 1) Cost Estimate Summary 2) List of Value Engineering Approaches Applied to Project 3) Project Design 59 1/5/2016 Vail Fire Station #1 - East Vail Conceptual Estimate 12/23/2015 Bid Item # Bid Description 110,035 Assumes 6 months total duration Budget Subcontractor 1 Demolition and Protection of Finishes $ 67,500 GEJ Estimate 2 Earthwork, Utilities, Landscaping $ 159,493 GEJ Estimate 3 Concrete & Asphalt $ 102,094 GEJ Estimate 4 Masonry $ 31,040 GEJ Estimate 5 Steel $ 26,975 GEJ Estimate 6 Rough Carpentry $ 132,500 GEJ Estimate 7 Interior Carpentry $ 40,750 GEJ Estimate 8 Exterior Envelope $ 68,370 GEJ Estimate 9 Doors, Windows, Hardware $ 80,710 GEJ Estimate 10 Roofing $ 47,425 GEJ Estimate 11 Drywall & Framing $ 50,583 GEJ Estimate 12 Painting $ 28,778 GEJ Estimate 13 Flooring $ 44,064 GEJ Estimate 14 Tile $ 2,990 GEJ Estimate 15 Equipment $ 29,400 GEJ Estimate 16 Fire Sprinkler $ 40,555 GEJ Estimate 17 Plumbing & Mechanical $ 198,320 GEJ Estimate 18 Electrical & Fire Alarm $ 183,887 GEJ Estimate 19 Misc Code Upgrades $ 20,000 GEJ Estimate 20 Existing Conditions Allowance $ 20,000 GEJ Estimate Bid Item Subtotal $ 1,375,434 General Conditions ( 8.0% ) $ 110,035 Assumes 6 months total duration Estimating Contingency ( 5.0% ) $ 68,772 Construction Contingency ( 3.0%) $ 43,326 Escalation ( 0.0%) $ - Subtotal Direct Construction Costs $ 1,487,532 Indirect Costs Building Permit & Plan Review Fees $ - Not included Contractor's Insurance $ 15,823 Builder's Risk Insurance $ 3,165 DIC Insurance $ - SDI Insurance Performance and Payment Bond $ 12,500 CM/GC Fee $ 63,292 Taxes (Gross Receipts, Sales, Use, Country, City, etc.) $ - Included Subtotal Direct & Indirect Costs $ 1,582,312 Site Impact Costs City Imposed Impact Fees $ - By Owner Site Development Fees $ - By Owner Water Connection Fees $ - By Owner Electrical Primary Fee $ - By Owner Construction Materials Testing & Inspections $ - By Owner Subtotal Project Costs $ 1,582,312 Other Project Costs Preconstruction Services $ - Preconstruction Reimbursable $ - Design & Engineering Fees $ - Owner's Project Contingency $ - Total Project Costs $ 1,582,312 Alternates EHU Finishes based on $200 / SF; 1400 SF total $ 299,600 Phased construction - Bay & Duty Quarters for first half, east side for the 2nd half $ 1/5/2016 55,017 VFS EHU cost was $174/SF Assumes 9 months total duration Vail Fire Station #1 Renovation 12/23/15 Pricing Update Following Value Engineering and Analysis of Estimate - Reduced quantity of drywall from 8,111 SF to 6,500 SF - Interior wood framing number: Reduced the total number from $16,222 to $12,000. This is a tough number to analyze because the amount of interior framing is not clear. - North window/stair tower: o Removed new CMU wall construction that was assume for 1 story o Added glass block/ window assemblies at existing tower o Added new stair framing at tower as this was not originally considered o VFS logo by Owner if desired at north tower - Landscaping: Reduced landscaping budget from $60,000 to $30,000 - CMU reduction to 4" AFF and then framed wall o Reduce the height of the wall from 10' to 4' at the 15t floor garage area and reduced cost from $25/SF to $20/SF o Added drywall framing and finishing in its place at $8/SF - Retaining wall: Reduced $15,000 concrete retaining wall to $7500 for a stone / boulder retaining wall. - Reduce quantity of windows and reuse some openings: o Reduced quantity of window supply from 56 to 46. The affects the window supply number, the window and door install number and the window and door trim number. (Note that the total number of exterior doors and windows was 66 and has now been reduced to 56.) o Swapped out one sliding door at Duty Quarter kitchen but added the same cost for cabinets - Reduced railing cost from $150/1-F to $115/1-F - Analyzed cost of weight room. The weight room is 643 SF. For minimal electrical, heating, drywall and finishes in the weight room, we can assume $50/SF totaling about $32,000 for this area. Analyzed leaving weight room in current location, this would result in EHUs being on separate floors - Exterior siding: made no changes as Corten was not originally considered. Conceptual Estimate had wood siding and stucco only as Corten was not clearly called on out drawings. Gen3 (installer of Corten at Vail 21 and Lionshead Transit Center) to provide SF pricing but this has not been received yet. - Added Hydrotech waterproofing over large Duty Quarters deck. - Reduced misc. code upgrades from $40,000 to $20,000 - Reduced existing conditions allowance from $30,000 to $20,000 1/5/2016 4 DRB 3D VIEW EXISTING 2 LL le E q)3D VIEW PROPOSED 2 1 • 1 1/5/2016 I� 12.17-15 C] DRB _I m U 3D VIEW - EXISTING 3 yr M Zo O N W i= amope �WcO Nz0 U) xm,_ 0 w LL F a J a o' 3D VIEWS 3D VIEW - PROPOSED 3 U A9.03 1/5/2016 TOPODRAPHIDLEDEND n NOTE: CONTOUR DRB 12.17 Zo15 INTERVAL 0.5' (6") O s z Z e O v iC)°uj pr U)z f O E =J— L W CoQ .e \\ \I LL �v l a 6 d ' ....... ... SITE PLAN ab r1. SITE PLAN v r•=,a-o PLAN NORTH A0.05 1/5/2016 DEMOLITION LEGEND 21315 Dae \J t/ 1/5/2016 — A PLAN NORTH r za 0 7)W > Q j W Zmo `m U) xmu = J L OD W 00— .e mo>a LL a J � A7 �LEVEL2-EXISTINGEXISTING I \ ��flt6"=tb"=tb' \ I � i DEMOLITION LEGEND O I I I 12.1] 1S I I I I I I I I t I I I I I I asa I I I DRB 2u —_—_—_—_—_--_�_�_—_� i 42STORAGE I I I I I I I EM I I I I I I I I 7,5 ® �0 EHD ki�LINNG KtrCHEN (E tl[� --EHU CORRIDOR 3. � marvx 0 BEDROOMI (EHu 1) --.-. - ®= as 4 -EV - 5 n, II \ \ I I - I I I I ----------------- �T- - ------_ ----- I I I I I I I I I I I I I I I I I I I I I I I I I ) I I I I I I I I I I I I I I 4- 8 A "I.4 E 1/5/2016 �' gtiw g F �- 4 I f it �ol2aieisoi'm N LEVEL 2168 z PLAN NORTH A1.02 DEMOLITION LEGEND 0 I I I I I I I I I 1z„ ,fi I I I I I I I I I I I I I I I v LE' EL3 -0E%ISTINO \ \ \ I I I I I I I I 7.5 � A,o, IIS II I I I I I I I \ AREA BELOW I I s I /�y.� '. (� 3R0 FLOOR I V) x 2 STORAGE BE ROOM 1 IE BEDROOM Z `V' 0 ® = J J wa.as moi i LL a �zoa Jz„ I O z9a — \ \ OU . R I I o O lAW M PCLOSE � �, 1k � w, I `4 \ sx� 11 I�G ROOM NIT � \ I wrv�io I _ _ — _ — _ — _ — _ — _ — _ — _ _ _ — _ —I_ — _ _ ♦— _ _ — — _ — _ — _ — _ — I I I I I I I I I I I I I I I II ®LEVEL 3 -PROPOSED s�vzulaoiw &4fi,'�" 'I ila�ol neaso —_—_—_—_—_—_—_—_—_—_—I_—_-_L_LL— — _—_ LEVEL3 I I I I � I A1.03 �s �c 14 F.4 F.1 F.z PLAN NORTH 1/5/2016 vLEVEL d (ENU LOFr)- EXISTING 1/i6"=4E DEMO -ON LEGEND E—T— E= 15 DRB I I I I I /1 LEVEL' (-0EHU LOM - PROPOSED PLAN NORTH 1/5/2016 Z z i O a L W Q jW/D N Z aD C/)xmu =J- W L C7O<.e m0" I � LL a Q @�k fC F. 8 4 t(a�olVne�oi�aioN�eeaaz LEVEL4(EHU LOFT) A1.04 QI DEMOLITION LEGEND \ I I I I I I I I O \ I I I I I I \ I I DRB 2Y'IS \ I I I I I I IIW � \ III I I I I I I I I I I I I I I I I I I I I I I I I I I I I LEVEL 51F5 LOFT-E—NG )_------- -----------I— 2 T. 3 , MEz az e I 5,1 i o N >- / m ; Q 0 W D zmo `m I U) xm() i o D It W oo—.e LL �a Q II I > Room Raam ❑ I �8- a 1k f C II I I I SII I I � — s I I I I I I I I I I I I I I I LEVEL 5ro(FS� LEVELS SLOFT-PROP ED �� � LOFT) 78 � 7C D F.3 F.4 E F.1 PLAN NORTH A1.05 1/5/2016 KEYNOTE LEGEND 0 VALUE YNOTE TEXT 1 CEMENTITIOUS SHAKE SIDING, NICHIHA 2 STUCCO, 3-COAT 3 2X WOOD WINDOW TRIM 4 NEW WINDOW 5 EXISTING METAL ROOF 6 PROPOSED METAL ROOF B BALCONYWITHRAILINGZB15 DRB ll .I � �„ III „III III„ III „III III„ III „III III III „III III=III „III-III=III „III=III III ,III � �---_---- - vEAST ELEVATION (—N)- EXISTING Ile' r Z z Q Qw N a IY IY IY Q � m I O vJ LU ?QQ E ism'>a I J � I I I I Q ILEVEL 4(EHU —_—_-1,o & -�qw F. �� 4--- --- 113'111 �. I I I I I I — 06' LEVE VAICF�F$TA 1-iIV � I I I O• Ec� .v —I T = T_- -� I J-11L----IJam. BJ -1 ---- --- 'III—III—III I I I�I I I—III III III—III III III—III II— — I III III—I I —III III—III— I I III— I I —III I I I I I I I —III III III III III III—III III—III I I I—III—III—III III—III—III -III—III III— tOP� I I I I I I I I I EABT ELEVATION IMAINI - PROPOBED ilpaolVi�e�soipioN bexp 0 1µ"=1'-0" EAST (MAIN) ELEVATION A2.01 1/5/2016 f. SOVTH(E NTRYIELEVATION-EXISTING KEYNOTE LEGEND KE B , A ' VALUE KEYNOTE TEM 1 CEMENTITIOUS SHAKE SIDING, NICHIHA 2 STUCCO. WNDC 5 2M WiO DOINDOW TRIM 5 NEW WINDOW 5 _STING"' XISTI ME L ROOF 6 PROPOSSEDED METAL ROOF 8 BALCONY WITH RAILING 12. 1].2515 DRB I I n E45T ELEVATION - EXISTING SOUTHEAST(ENTRY)ELEVATION- 1/5/2016 y �o�+ie.uoi o c�>4+aexz SOUTHEAST, EAST A2.02 KEYNOTELEGENO KEY VALUE KEYNOTE TEM 1 CEMENTITIOUS SHAD SIDING. WCHIHA DRB 2018 2 STUCCO. 3 COAT 3 2XW000WIN00WTRIM A NEWWINDOW 5 EXISTING METAL ROOF 8 PROPOSED METAL ROOF S BALCONY WITH RAILING Jill 111 lill 11111 lill 111 1 mmff i, NORTH ELEVATION -EXISTING 118' =" r Z z Q 0 7 Q mwm� L z vJ=JJ� LL m m > I P LEVEL 'LOE� W E F. 11TLE 1EtI2" dp 108' 11" V L, El 01 _ illil IL MI II LT iiWi=Fr liil "i Ill�l ll��ILI_IT1 II 1111111 11 111 1111 1L IIITII IL�III IFlii NORTH ea NORTH ELEVATION -PROPOSED ELEVATION U , =1'-0' A2.03 1/5/2016 KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT e Mum lu 2815 1 CEME- TIOUS SHAKE SIDING, NICHIHA DRB 2 STUCCO, 3 -COAT S 2X WOOD WINDOW TRIM d NEW WINDOW O S EXISTING METAL ROOF _ 8 PROPOSED METAL ROOF 8 BALCONY WITH RAILING /. NORTH WESTELEVATION-EXISTINGnWEST ELEVATION -EXISTING V ire•=1'-0" U ire•=1'-0" r � `�q' Y z �Z I I I VJ ��OU I I I I = J L � LLJ I H FEE] r LEVEL aL�oFi - EL-� -EEE - - irFT 00 - LEVELS "& a - — - „2 ,, 1 op L1BDE`s I_J=P1—I JJ� I I LL=I 1 I=III=I 1=1 =III=I 1=1 =I ISI 1=1 =III=I ISI =T=I I LI I I—I I LI I I—III—III—III—III—I III—III—III—III—I III—I I I�I I I I I— -` I I I I I I Ha,olVne�oi�aioN,beaaz SOUTHWEST, SOUTHWEST ELEVATION -PROPOSED WEST ELEVATION -PROPOSED SOUTH va•=,w� v va•=ro• A2.04 1/5/2016 KEYNOTE LEGEND KE VALUE KEYNOTE TEXT 1 CEMENTITIOUS SHAKE SIDING, NICHIHA STUCCO, 3 -COAT S 2 WOOD WINDOW TRIM 4 NEW WINDOW B 5 EXISTING METAL ROOF +S 6 PROPOSED METAL ROOF S BALCONY WITH RAILING DRB 3Y IFF[I r1 WEST -EXISTING �'J r 76 , t, J 7C T`7� l t /,IY `IT F.1 z Z O w _ j> oar: mwm� z m o 'mu E 0 vJ W =0¢ e LL V I I I I I I Q I I II I I 1 1 LEVEL4 (EHU e I I I I - - - - - - - - -- EL, 7ELP I I I I I I 30. I I I I I UI1 - iW'-D"lI WEST B wesrvRGvoseo ELEVATIONS A2.05 1/5/2016 KEYNOTELEGENO KEY VALUE I KEYNOTE- 1 EYNOTETEIR1 CEMENTITIOUSSHAKE SIDING,NICHIHA STICCO, 3-COAT 3 2X WOOD WINDOW TRIM36 15 4 NEW WINDOW DRB 5 EXISTING METAL ROOF 6 PROPOSED METAL ROOF 8-CONYWITH RAILING -1 11-III-11IJ I IJ I1=11IJ I I� I IJ I I=1 I I-11IJ I1=1 I IJ I IJ I I`I 11-1I I-1I1=1 I I I IJ I I. �. SOUTH ELEVATION -EXISTING .1r Z z 0 7A f61 f51 4:9 441 `31 e21 111 , O j o: Q mwm� zmo c U) xm° O J L W OoLL Q'e Ism'>a �a I I I I I I Q ------�--------- »,--------------rs,D I I \ I LEVEL4(EHU L. F. �� 4 �. I — -, ;EVEL2 I I I I I I I I I I ❑� � t1 I f �rl �4za+I-�Iu _LEVEL 1--=I - ..L -100 —IIIII III� IIII II I„ ll-1 I� II ,III II II ;III-III=III II —I I= —I r — � u 5 I-I ELEVATION PROPOSED ELEOVA ION �_ A2.06 1/5/2016 KEYNOTE LEGEND HEY VALUE KEYNOTE TEM 1 —ENT —US SHAKE SIDING, NICHIHA STUGGO, 3 -GOAT 3 2Y WOODWIND OW TRIM 4 NEW WINDOW FASTING METAL ROOF fi PROPOSED METAL ROOF BALCO 0. NY WITH RAILING 15 DRB 30 PO 1 Ll LI I' I- I1=1I1=1I H H I1=1I1=1I1=1I1=1I 1=1I1=1I1=1I1=1I1=1I I: I CI I I—III—I I �I I LI I LI I LI I I—III—I I ILL I I—I I I� I LI I I—I I IJ I CI r /.. NORTHWEST ELEVATION -FASTING U 110•=1'-0" zZ_ O O �j Q mwm� N?� =Jzmo IE _j L LU o¢'e m�>a � I LL � a I J � ®RN a. 1w fC F. .� 4 un LEVEL4(EHU I rn _LEVELS /� 113'-1112' V LEV�EL]�� P LEVEL_ 1 I� I -I �I I -III -III -III -I �I �I-III �I-I I -III -III -I I -I 1=. - - - - - - - - - I -III -III -I I� �I -I I� I -III -I Imo -III-III-I 11 -I -III-III I I III -III -III -III -III -I -I �I -III-I �m �I=1 C—III-1-1-1-1 IJ L—III-1 IJ IJ -1 IJ -1-1 LJ �I L= :Is1o1+i!„su�oi Ism,N beaaz NORTHWEST ELEVATION NORTHWEST ELEVATION -PROPOSED U 31 F 1'-0' A2.07 1/5/2016 TOWN OF VAIN VAIL TOWN COUNCIL AGENDA MEMO MEETING DATE: January 5, 2016 ITEM/TOPIC: Adjournment (7:55 p.m.) NOTE: UPCOMING MEETING TOPICS AND ESTIMATED TIMEFRAMES BELOW (ALL ARE APPROXIMATE DATES AND TIMES AND SUBJECT TO CHANGE) THE NEXT REGULAR VAIL TOWN COUNCIL MEETING WORK SESSION WILL BEGIN AT APPROXIMATELY 12:30 P.M. (or TBD), TUESDAY, JANUARY 19, 2016 IN THE VAIL TOWN COUNCIL CHAMBERS. Ongoing agenda items DRB/PEC updates WS - 15 min.; Information Updates Attachments: WS - 15 min.; Executive Session items: 30 min.; Consent Agenda: 5 min.; Town Manager Report: 5 min. Future agenda items: Summit County Housing Tour - 1/12 Special Meeting for Housing Discussion -TBD Review Matrix on Multi -Use Facilities - TBD Vail Municipal Building Remodel Update - TBD Cleanup Title 12, zoning amendments- TBD Gore Creek Water Quality Plan Update - TBD Vail Trails Update - TBD Environmental Strategic Plan Update - TBD Eagle County School District Meeting w/ Board - TBD Ford Park Leases - TBD Peer City Visit to Aspen - TBD Open Lands Strategic Plan - TBD Pedestrian Crossings at Roundabouts & Bus Shelters Discussion - TBD VRD Agreement for Skate Park - TBD 1/5/2016