HomeMy WebLinkAbout1970-11 Amending Ordinance 6, Series 1969, Adopting by Reference the "Uniform Building Code" Changing Certain Requirements for Construction-~~• ~ ~ ~
ORDINANCE PdO. ~/
Series of I970
~.
AN ORDINANCE AMENDING ORDINANCE N0. 6 OF THE ORDINANCES OF
THE TOt~IN OF VAIL, 1969 SERIES, ADOPTING BY REFERENCE THE t
"UNIFORM BUILDING CODE" 1967 EDITION: CHAPIGING CERTAIN REQUIRE-
MENTS FOR CONSTUCTION: AND SETTING FORTH DETAILS RELATING THERE,-
T0.
G7HEP.EAS, the Board o.f Trustees for the Town of Vail
adopted ORDINANCE N0. SIX (6), Series of 1969, on the 12th
day of May, 1969, which duly adopted by reference the '°Uniform
Buidling Code", 1967 Edition, and the "Uniform Mechanical Code",
1967 Edition, regulating the construction, alteration, repair,
removal, demolition, equipment, use and occupancy, location, _••°~
maintenance of buildings and other structures areacted in the
Town of Vail, and matters related thereto; and,
WHEF:EAS, The Board of Trustees has considered certain
amendments to the "Uniform Building Code", and finds that it is
necessary and proper to make certain changes set forth in the
provisions of said Building Code;
NOW, THEREFORE, BE IT OP.DAINED BY THE BOARD OF
TRUSTEES OF THE TOG~N OF VAIL, COLORADO, THAT:
5eetion`l.`Section 1305 (a) of the Uniform Building
Code, 1967 Edition. shall be amended by deleting said section
and substituting therefore the following:
"Light and Ventilation. _'111 guest rooms, dormitories,
end hahitah~_e rooms within a dwelling unit shall be
provided with natural light by means of windows or
skylights with an area of not less than oiie-tenth of
the floor area of such rooms with a minimum of 12
square feet. All bathrooms, water closet compartments
laundry rooms, and similar rc,oms shall be provided with
natural ventilation b_y means of windows or skylights
with an area of not less than one-tenth of the floor
area of such rooms with a minimum of 3 square feet.
Not less than one-half of the required window or sky-
light ar~aa shall be openable to provide natural ven-
ti.lation.
In lieu of openable windows for natural ventilation,
a mech~.nical ventilation system may be provided. Such
system shall be capable of providing two air changes i~er
hour in all guest rooms, dormitories, habitable rooms,
and in public corridors. One fifth of the air supply
shall be taken from the outside. In bathrooms, water
closet compar-tJnents, laundry rooms, and similar rooms
a mechanical ventilation system connected directly to
the outside, capable of providing five air changes
per hour, shall be provided.
For the purpose of determining light and ventilation
requirements, any room may be considered as a portion
of an adjoining room when one-half of the area of the
common wall is open and unobstructed and provides an
opening of not less than one-tenth of the floor area
of the i.nter3_or room. or 25 square feet, whichever is
greater.
Required windows sh~311 open directly onto a street or
public alloy or a yard or court locted on the same lot
as the building.
EXCEPTION: Required windows may open into a roofed
porch where the porch: 1. abuts a street, yard, or
court; and 2. has a ceiling height of not less than 7
feet; and 3. Has the longer side at least 65 percent
open and unobstructed.
• ~ r ~•
Section 2. The Board of Trustees find that this or-
dinance is necessary to protect the public health and welfare;
that this ordinance shall become effective upon its introduction
and adoption and shall be published in accordance with the laws
of the State of Colorado.
INTRODUCED, READ r?ND ORDEF?F'D PUBLISHED THIS~~DAY
OF 1`~UGUST, 19 7U .
.~
Mayor
ATTEST:
' Town Cf~~k /