Loading...
HomeMy WebLinkAbout2005- 4 Repealing and Reenacting Chapter 10-1 Building Codes, Vail Town Code; Adopting by Reference the 2003 Editions of the International Building Code, International Residential Code, International Fire Code, and Others ORDINANCE N0.4 SERIES OF 2005 AN ORDINANCE REPEALING AND REENACTING CHAPTER 10-1, BUILDING CODES, VAIL TOWN CODE; ADOPTING BY REFERENCE THE 2003 EDITIONS OF THE INTERNATIONAL BUILDING CODE, INTERNATIONAL RESIDENTIAL CODE, INTERNATIONAL FIRE CODE, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL FUEL GAS CODE, INTERNATIONAL ENERGY CONSERVATION CODE; 2002 EDITION OF THE NATIONAL ELECTRICAL CODE; AND WITH REGARD TO THE ABOVE-DESCRIBED CODES, ADOPTING CERTAIN APPENDICES, SETTING FORTH CERTAIN AMENDMENTS THERETO, AND SETTING FOR DETAILS IN REGARD THERETO. WHEREAS, publication of the 1997 Uniform Building Code (UBC), as currently adopted by the Town of Vail, has been discontinued; and . WHEREAS, the 2003 Editions of the Intemational Building Code (IBC), the International Residential Code (IRC), the Intemational Fire Code (IFC); the International Mechanical Code (IMC); the International Plumbing Code (IPC); the International Fuel Gas Code (IFGC); the Intemational Energy Conservation Code (IECC) and the 2002 Edition of the National Electric Code (NEC) have been published; and WHEREAS, the Building and Fire Code Board of Appeals of the Town of Vail has recommended adoption of the International Codes, asset forth in this ordinance, and has submitted its recommendation to the Vail Town Council; and WHEREAS, the Vail Town Council finds that the proposed amendments further the development objectives of the Town of Vail; and WHEREAS, the Vail Town Council finds that the amendments promote the health, safety, morals, and general welfare of the Town and promote the coordinated and harmonious development of the Town in a manner that conserves and enhances its natural environment and its established character as a resort and residential community of the highest quality. NOW, THEREFORE, BE IT ORDAINED BY THE TOWN COUNCIL OF THE TOWN OF VAIL, COLORADO, THAT: Section 1. Chapter 10-1, Building Codes, Vail Town Code, is hereby repealed and Ordinance No. 4, Series of 2005 1 reenacted to read as follows: CHAPTER1 BUILDING CODES SECTION: 10-1-1: Preamble 10-1-2: Codes Adopted By Reference 10-1-3: Amendments to Intemational Building Code 10-1-4: Amendments to International Residential Code 10-1-5: Amendments to Intemational Fire Code 10-1-6: Amendments to Intemational Mechanical Code 10-1-7: Amendments to Intemational Plumbing Code 10-1-8: Amendments to Intemational Fuel Gas Code 10-1-9: Amendments to National Electrical Code 10-1-10: Copies of Codes Available 10-1-11: Penalties 10-1-1: PREAMBLE: The Charter of the Town of Vail and the statutes of the State of Colorado provide that standard codes may be adopted by reference with amendments; and the Town of Vail wishes to adopt the 2003 editions of the Intemational Building Code, the Intemational Residential Code, the Intemational Fire Code, the Intemational Mechanical Code, the Intemational Plumbing Code, the Intemational Fuel Gas Code, the Intemational Energy Conservation Code, and the 2002 edition of the National • Electric Code. 10-1-2: CODES ADOPTED BY REFERENCE: A. Building Code: The International Building Code, 2003 edition, including Appendix Chapter J and the International Residential Code, 2003 edition, including Appendix G, is hereby adopted by reference. The Intemational Building Code, 2003 edition and the International Residential Code, 2003 edition, is published by the International Code Council, 4051 West Flossmoor Road, Country Club Hills, II 60478-5795 B. Fire Code: The International Fire Code, 2003 edition, is hereby adopted by reference. The Intemational Fire Code, 2003 edition, is published by the Intemational Code Council, 4051 West Flossmoor Road, Country Club Hills, II 60478-5795. C. Mechanical Code: The International Mechanical Code, 2003 edition, including Appendix A, is hereby adopted by reference. The Intemational Mechanical Code, 2003 edition, is published by the Intemational Code Council, 4051 West Flossmoor Road, Country Club Hills, II 60478-5795. D. Plumbing Code: The Intemational Plumbing Code, 2003 edition, is hereby adopted by reference. The Intemational Plumbing Code, 2003 edition, is published by the Intemational Code Council, 4051 Flossmoor Road, Country Club Hills, II 60478-5795. E. Intemational Fuel Gas Code: The International Fuel Gas Code, 2003 edition, is Ordinance No. 4, Series of 2005 2 hereby adopted by reference. The Intemational Fuel Gas Code, 2003 edition, is published by the International Code Council, 4051 Flossmoor Road, Country Club Hills, II 60478-5795. F. Energy Code. The International Energy Conservation Code, 2003 edition, is hereby adopted by reference. The International Energy Conservation Code, 2003 edition, is published by the Intemational Code Council, 4051 Flossmoor Road, Country Club Hills. G. Electrical Code: The National Electrical Code, 2002 edition, is hereby adopted by reference. The National Electrical Code is published by the National Fire Protection Association Inc., One Batterymarch Park, Quincy, Ma 02269. 10-1-3: AMENDMENTS TO INTERNATIONAL BUILDING CODE: The following amendments are hereby made to the International Building Code, 2003 edition: SECTION 101.4 -REFERENCED CODES: Section 101.4, Referenced Codes, is hereby amended as follows: The other codes listed in 101.4.1 through 101.4.7 and referenced elsewhere in this code shall not be considered part of this code, unless specifically adopted. SECTION 105.1.1 -ANNUAL PERMIT: Delete section in its entirety. . SECTION 105.2 -WORK EXEMPT FROM PERMIT: Section 105.2, Work exempt from permit, is hereby amended as follows: Item 6: Decks, patios, sidewalks and driveways not more than 30 inches above grade and not over any basement or storage below and which are not part of an accessible route. Item 11: Swings and other playground equipment. SECTION 108.2 -SCHEDULE OF PERMIT FEES: Section 108.2, Schedule of permit fees, is amended as follows: The construction fee schedule for the Town of Vail shall be on file and maintained in the office of the Community Development Department. SECTION 108.3 -BUILDING PERMIT VALUATION: Section 10$.3, Building permit valuation, is hereby amended as follows: The valuation of building permits in the Town of Vail shall be based on the most recent cost figures, per square foot as shown in the Intemational Building Safety Journal published by the Intemational Code Council, a copy of which shall be on file in the Department of Community Development of the Town of Vail. All construction shall be deemed "good". SECTION 110 -CERTIFICATE OF OCCUPANCY: Section 110.1, Use and occupancy, is hereby amended as follows: No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy therefor as provided herein. Exception: Additions, alterations or repairs to existing Group R, Division 3 and Group U Occupancies. Issuance of a certificate of occupancy shall not be construed as an approval of a Ordinance No. 4, Series of 2005 3 violation of the provisions of this code or of other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. SECTION 1025 -EMERGENCY ESCAPE AND RESCUE: Sectron 1025.1, General, i is hereby amended as follows: Exception 1 & 4, delete in their entirety, r and snow loads is hereb SECTION 1608 -SNOW LOADS: Section 1608.2, G o y amended as follows: Designs for roof snow loads shall be as follows: Roof pitches of less than a 4:12, shall be designed to carry a 100 pound per square foot (psf) snow load and roof pitches of 4:12 and greater shall be designed to carry an 80 pound per square foot (psf) snow load. There is no allowance for pitch reduction nor is there a requirement to increase loading due to wind, valleys or type of roof covering. Any modification for snow load design shall be accomplished using section 104.11. SECTION 3403.1- EXISTING BUILDINGS OR STRUCTURES: Section 3403.1, Existing buildings or structures, is here by amended by adding the following: Every condominium association or owner of a building or structure built before 1991 shall within 18 months of the adoption of this code, provide to the Town of Vail a copy of a Fire Risk Assessment (FRA). The FRA shall be developed bythe Town of Vail's Fire Prevention and Fire Marshal's office. The FRA shall contain necessary elements and be in sufficient detail as to provide a basis for determining applicability of retroactive application of code provisions. Minimum components shall comply with the adopted Town of Vail Standards. Buildings subject to this requirement include: 1. Group A, B, E, F, H, I and S 2. Group M with more than one floor, 3. Group R-1 and R-2 with more than two stories, more than 12 accommodation units, or dwelling units, 4. Group R-3 over three stories, excluding Group R-3 regulated by the Intemational Residential Code, 5. Any building or structure more than 5000 square feet of floor area, per floor, 6. Any building or structure where all points of the first story are more than 150 feet from a single point of approved fire department access. Upon submission of the FRA, the Town will evaluate the results and determine applicability of retrofit provisions in accordance with the Town of Vail Design Guidelines. 10-1-4: AMENDMENTS TO INTERNATIONAL RESIDIENTIAL CODE: The following amendments are hereby made to the Intemational Residential Code, 2003 edition: SECTION R102 -APPLICABILITY: Section R102.4, Referenced codes and standards, is hereby amended by adding the following: Reference to other codes such as Plumbing, Mechanical and Electrical shall refer only to the currently adopted code of that type. • SECTION R105 -PERMITS: Section 105.2, Work exempt from permit, is hereby Ordinance No. 4, Series of 2005 4 amended as follows: Item 1: One-story detached accessory structures used as tool sheds, storage ' sheds, playhouses and similar uses provided the floor area does not exceed 120 square feet Item 5: Decks, patios, sidewalks and driveways not more than 30 inches above grade and not over any basement or storage below and which are not part of an accessible route. SECTION - R301.2.4. FLOODPLAIN CONSTRUCTION: Section 301.2.4 Floodplain construction is hereby amended as follows: Delete section in its entirety and replace with: Building and structures constructed in flood hazard areas are subject to section 12-21-1 of the Vail Town Code. SECTION - R303.8 REQUIRED HEATING: Section 303.8, Required heating, is hereby amended by adding the following: Minimum winter design temperature is -20° F. Heat loss calculations shall be required for all dwelling units. SECTION R303.9 -HEATING EQUIPMENT ROOMS; Add Section R303.9, Heating equipment rooms, as follows: In R-3 occupancies, rooms containing a boiler, central heating plant or hot water supply boiler in excess of 400,000 Btu per hour input shall be separated from the rest of the building by not less than 1-hour fire-resistive construction on the room side of the heating equipment. Opening protection shall be obtained by use of a tight fitting, smoke-and draft-control, self-closing assemblies having afire-protection rating of not less than 20-minutes. All spaces containing fuel- fired equipment located in under-floor (crawlspace) and above-ceiling (attic) areas shall be separated from the rest of the building by not less than 1-hour fire-resistive construction on the space side of the heating equipment regardless of Btu input. Opening protection shall be obtained by use of a tight fitting, smoke-and draft- control, self-closing assemblies having afire-protection rating of not less than 20- minutes. All under-floor and above ceiling spaces shall have smoke or heat detection and automatic fire sprinklers in accordance to Vail Fire Department standards. SECTION R305 -CEILING HEIGHT: Section R305.1, Exception 2, is hereby amended by deleting this exception in its entirety. SECTION R310 -EMERGENCY ESCAPE AND RESCUE OPENINGS: Section R310.1, Emergency escape and rescue required, is hereby amended as follows: First paragraph, first sentence amended as follows: Basements and every sleeping room shall have at least one openable emergency escape and rescue opening. SECTION R403.1.4.1 -FROST PROTECTION: Section R403.1.4.1, Frost protection, is hereby amended by deleting this section in its entirety and replacing with the following: Foundation walls, piers and other permanent supports shall be protected from frost by providing a minimum depth of 48" measured from finished grade to the bottom of the footing. Where applicable, the depth of the footing shall also conform to Sections R403.1.4.1 through R403.1.4.2 SECTION R403.2 -FOOTINGS FOR WOOD FOUNDATIONS: Section R403.2, Footings for wood foundations, is hereby amended by adding the following: Ordinance No. 4, Series of 2005 5 • Foundations shall be designed by a registered Colorado Engineer and approved by the Geotechnical Engineer. SECTION R403.3 -FROST PROTECTED SHALLOW FOUNDATIONS: Section R403.3, Frost protected shallow foundations, is hereby amended by adding the following: Foundations shall be designed by a registered Colorado Engineer and approved by the Geotechnical Engineer. CHAPTER 12 -CHAPTER 42: Delete in their entirety and reference other codes adopted by reference respectively. 10-1-5: AMENDMENTS TO THE INTERNATIONAL FIRE CODE: The following amendments are hereby made to the International Fire Code, 2003 edition: SECTION 103 - DEPARTMENT OF FIRE PREVENTION: Section 103, Department of Fire Prevention shall be hereby amended as follows: Title shall be changed to: Fire Prevention Bureau. SECTION 103.1- GENERAL: Section 103.1, General, shall hereby be amended as follows: Delete section in its entirety and replace with: A fire prevention bureau established within the fire department under the direction of the Chief shall consist of fire department personnel assigned thereto by the Chief. The function of this bureau shall be to assist the Chief in the administration and enforcement of the provisions of • this code. SECTION 103.1.1- FIRE MARSHAL: Add Section 103.1.1, Fire Marshal: The Chief is authorized to designate a member of the fire department to exercise the powers and perform the duties of fire prevention engineer as set forth in this code. The fire prevention engineer may also be known as the fire marshal. SECTION 104.1.1 -FIRE PREVENTION BUREAU AND PEACE OFFICERS: Add Section 104.1.1, Fire prevention bureau and peace officers: The Chief and members of the fire prevention bureau shall have the powers of a peace office, (as defined per C.R.S. 18-1-901, 3(I) (III) in performing their duties under this code. When requested to do so by the Chief, the chief of police is authorized to assign such available peace officers as necessary to assist the fire department in enforcing the provisions of this code. SECTION 106.2.1 -INSPECTION REQUESTS: Add Section 106.2.1, Inspection requests: It shaft be the duty of the person performing the work authorized by a permit to notify the Chief that the work is ready for inspection. The Chief is authorized to require that every request for inspection be filed not less than one working day before such inspection is desired. Such requests may be in writing or by telephone at the option of the Chief. SECTION 110.1.3 -UNSAFE HEATING OR ELECTRICAL EQUIPMENT AND STRUCTURAL HAZARDS: Add Section 110.1.3, Unsafe heating or electrical equipment and structural hazards: When the Chief deems any chimney, smokestack, stove, oven, incinerator, furnace, or any other heating device, electric Ordinance No. 4, Series of 2005 6 • fixture or any appurtenance thereto, or anything regulated under a nationally recognized standard in or upon any building, structure or premises not specifically mentioned in this code, to be defective or unsafe so as to create a hazard, the Chief is authorized to serve upon the owner or the person having control of the property a written notice to repair or alter as necessary and shall notify any other authority enforcing codes regulating such equipment. The Chief is authorized to affix a condemnation tag prohibiting the use thereof until such repairs or alterations are made. When affixed, such tag shall only be removed by the order of the Chief when the hazard to which the order pertains has been eliminated in an approved manner. Until removed, that item or device which has caused the hazard shall not be used or be permitted to be used. When such an apparent structural hazard is caused by the faulty installation, operation or malfunction of any of the items or devices listed in this section, the Chief shall immediately notify the building official to investigate such hazard and cause such hazard to be abated as required by the building code. SECTION 111.5 -STOPPING USES, EVACUATION: Add section 111.5 Stopping uses, evacuation: The Chief is authorized to order an operation or use stopped or the evacuation of any premises, building or vehicle or portion thereof which is a fire hazard. SECTION 202 - F FALSE ALARM: Section 202, False alarm is hereby amended as follows: Delete False alarm definition and replace with the following: The activation of • a device or transmission of an alarm signal, indicating an emergency exists and/or necessitating response by the Vail Police Department or the Vail Fire Department, where no emergency exists. SECTION 202 F -FIRE CODE OFFICIAL: Section 202 F, Fire code official, is hereby amended as follows: Substitute Fire marshal for Fire code official. SECTION 305.5 -GAS METERS AND PIPING: Add section 305.5, Gas meters and piping, as follows: Above ground gas meters, regulators, and piping shall be protected from damage by ice or snow, and if exposed to vehicular damage due to proximity to alleys, driveways or parking areas, shall be protected from such damage in accordance with section 312.1 of this code. SECTION 508.5.5 -CLEAR SPACES AROUND HYDRANTS: Section 508.5.5, Clear spaces around hydrants, shall hereby be amended as follows: Delete entire section and replace with: A clear and unobstructed space shall be maintained around a fire hydrant with the following minimum distances: front -15 feet, rear - 4 feet, sides - 7 feet. Fire hydrants shall be installed and maintained to provide a minimum of 36 inches of clearance between the centers of the outlet caps and finish grade. Standards set forth by other agencies including the water district, may be referenced and enforced providing the most restrictive shall apply. SECTION 610 -COMMERCIAL KITCHEN HOODS: Section 610, Commercial Kitchen Hoods, shall hereby be amended as follows: Delete entire section in its entirety and replace with: • SECTION 610.1 -VENTILATION HOOD AND DUCT SYSTEMS: Section 610.1, Ordinance No. 4, Series of 2005 7 Ventilation Hood and Duct Systems. A ventilating hood and duct system shall be provided in accordance with International Mechanical Code for commercial-type food heat-processing equipment that produces grease laden vapors. SECTION 610.1.2 -FIRE - EXTINGUSHING SYSTEMS: Add Section 610.1.2 Fire- Extinguishing Systems: Where a Type I hood is required to be installed; afire- extinguishing system shall also be required. SECTION 610.2 -WHERE REQUIRED: Section 610.2 Where Required: Approved automatic fire-extinguishing systems shall be provided for the protection of commercial type cooking equipment. SECTION 610.2.1 -TYPE OF SYSTEMS: Add Section 610.2.1, Type of Systems: The system used for the protection of commercial type cooking equipment shall be either a system listed for application with such equipment or an automatic fire extinguishing system that is specifically designed for such application. Systems installed shall meet or exceed U.L. 300 requirements, and shall be installed in accordance with Manufacturer's specifications and instructions. SECTION 610.2.2 -EXTENT OF PROTECTION: Add section 610.2.2 Extent of protection: The automatic fire extinguishing system used to protect ventilating hoods and ducts and cooking appliances shall be installed to include cooking surfaces, deep fat fryers, griddles, upright broilers, charbroilers, range tops and grills. Protection shall • also be provided for the enclosed plenum space within the hood above filters and exhaust ducts serving the hood. SECTION 610.2.3 -AUTOMATIC POWER, FUEL AND VENTILATION SHAFT: Add Section 610.2.3, Automatic power, fuel, and ventilation shaft: Automatic fire extinguishing systems shall be interconnected to the fuel or current supply for cooking equipment. The interconnection shall be arranged to automatically shut off all cooking equipment and electrical receptacles which are located under the hood when the system is actuated. Shutoff valves or switches shall be of a type that requires manual operation to reset. Hood ventilation system shall remain operational upon activation of system, unless authorized to perform otherwise by the Chief. Activation of an automatic fire extinguishing system shall transmit an alarm to the building fire alarm system. SECTION 610.2.4 -MANUAL SYSTEM OPERATION: Add Section 610.2.4, Manual I! system operation. A readily accessible manual activation device shall be installed in i, accordance with Manufacturer's requirements and those set forth in N.F.P.A. 17A, Standard for Wet chemical Extinguishing Systems. The activation device is allowed ~ to be mechanically or electrically operated. If electrical power is used, the system shall be connected to a standby power system and a visual means shall be provided to show that the extinguishing system is energized. Instructions for operating the fire extinguishing system shall be posted adjacent to manual activation devices. SECTION 610.2.5 -PORTABLE FIRE EXTINGUISHERS: Add Section 610.2.5, Portable fire extinguishers. A K-Class extinguisher shall be installed within 30 feet of commercial food heat processing equipment as measured along an unobstructed • path of travel in accordance with N.F.P.A. 10. Ordinance No. 4, Series of 2005 $ • SECTION 610.3 -OPERATIONS AND MAINTENANCE: Add Section 610.3, Operations and maintenance: The ventilation system in connection with hoods shall be operated at the required rate of air movement, classified grease filters shall be in place when equipment under a kitchen grease hood is used. If grease extractors are installed, they shall be operated when the commercial type cooking equipment is used. Hoods, grease removal devices, fans, ducts and otherappurtenancesshall be cleaned every six months, unless otherwise approved by the Chief, in writing. Cleanings shall be recorded, and records shall state the extent, time, and date of cleaning. A sticker or other indicating means shah be affixed to the hood. Cleaning records shall be maintained on the premises. Extinguishing systems shall be serviced at least every six months or after activation of the system. Inspections shall be by qualified individuals, and a Certificate of Inspection shall be both maintained on the premises and forwarded to the Chief upon completion. SECTION 610.4 -SKI SHOP REQUIREMENTS: Add section 610.4, Ski Shop Requirements, SECTION 610.4.1 SCOPE: Add section 610.4.1, Scope, as follows: This section shall apply to all commercial operations involving the processing, manufacturing, repair, waxing, preparation and associated functions with respect to snow skis, snow boards, snow boots, water skis, skate boards and other equipment with similar features. • SECTION 610.4.2 -EQUIPMENT: Add section 610.4.2, Equipment, as follows: All equipment used in the above operations shall be listed by an approved agency when the equipment uses heat, flame or power operations. Said equipment shall be maintained in good condition and used according to the manufacturer's recommendations. SECTION 610.4.3 -USAGE: Add section 610.4.3, Usage, as follows: Heat and flame producing devices shall be used only by qualified personnel and shall be equipped with a suitable base or holder. Said equipment shall not be used on work tables with combustible surfaces. SECTION 610.4.4 -ELECTRICAL: Add section 610.4.4, Electrical, as follows: All electrical appliances, fixtures and equipment shall be listed by an approved agency and shall be maintained in a safe and operable manner. Non-grounded extension cords and multi-plug receptacles are strictly prohibited. SECTION 610.4.5 -FLAMMABLE AND COMBUSTIBLE LIQUIDS: Add section 610.4.5, Flammable and combustible liquids, as follows: No more than one U.S. gallon (3.78 I) of flammable or combustible liquid shall be permitted on the premises at any time. All flammable liquids stored on the premise shall be stored in an approved container in a safe area. No flammable or combustible liquids shall be stored within 25 feet of any open flame or heat producing device capable of ignition. SECTION 610.4.6 -OPEN FLAME: Add section 610.4.6, Open flame, as follows: No open flame or heat producing device shall be left unattended while in operation. All • such devices shall be turned off, disconnected or extinguished if not in immediate use. Ordinance No. 4, Series of 2005 9 • SECTION 610.4.7 -VENTILATION: Add section 610.4.7, ventilation as follows: All shops in which toxic, flammable or poisonous gases or other vapors which are potential hazards shall be equipped with proper ventilation. Said ventilation systems shall be designed to have the capacity of providing 1.5cfm/ft2 per square foot of floor area. This mechanical system shall be provided by a method of supply and exhaust air. The amount of supply air shall be approximately equal to the amount of exhaust air. Said system shall be designed and installed in accordance to the International Mechanical Code, Chapter 6. Location of fans, hoods, when required by the Chief and ducts shall meet the approval of the Fire Department. SECTION 610.4.8 -INTERIOR FINISH: Add section 610.4.8, Interior finish, as follows: All ski shops shall have no less than one hour fire resistive assemblies for walls, ceilings and floors. Interior finish of the room shall be Class A, as tested in accordance to ASTM E 84. All work tables where the use of open flame or heat producing devices is permitted, shall be of non-combustible construction on the surface and all exposed surfaces adjacent to such production processes. SECTION 610.5 -TEMPORARY SKI REPAIR FACILITIES: Add section 610.5, Temporary ski repair facilities, as follows: Temporary ski repair facilities may be allowed under the following conditions: 1. Temporary ski repair facilities are defined as those designated and intended for less than 30 days use, and outlined in section 610.4.1. 2. Ventilation requirements for the immediate ski repair area may be waived, • provided the room or space in which the ski repair operation is located is provided with mechanical and/or natural ventilation sufficient to provide a minimum of six air changes per hour, or meets the International Building Code requirements for building usage. 3. Flammable liquid usage shall be limited to rooms equipped with automatic fire sprinkler systems. Maximum quantity shall not exceed one U.S. gallon. 4. Temporary ski repair operations shall not adversely affect the health or life- safety of the occupants of the building. 5. Temporary ski repair operations shall not be allowed to cause false alarms. It shall be the responsibility of both the building owner/manager and the operator of the ski repair operation to take appropriate measures to avoid false alarms (activation of fire detection system under non-emergency circumstances). 6. A frre extinguisher with a minimum rating of 2A40bc shall be provided for each 400 square feet of ski shop repair area. Such fire extinguisher shall be equipped with a service tag, provided by a licensed fire protection company, indicating that the extinguisher has been serviced and/or recharged within the last twelve months. 7. Temporary ski repair operations shall not be allowed within the residential portions, accommodation units, dwelling units, condominiums or sleeping rooms of buildings. Hazardous rooms shall not allow (i.e. -boiler rooms, HVAC, electrical rooms, rooms beneath stairs, non fire-rated attics, storage rooms and similar spaces). 8. All installations and features thereof are subject to the approval of the Fire Chief and Chief Building Official. • SECTION 804.1.1 -RESTRICTED OCCUPANCIES: Section 804.1.1, Restricted Ordinance No. 4, Series of 2005 ~ 0 occupancies, is hereby amended as. follows: Exception, Trees located in areas protected by an approved automatic sprinkler system installed in accordance with Section 901.3.1.1 or 901.3.1.2 shall not be prohibited in Groups R-1 and R-2. SECTION 902 -DEFINITIONS: Section 902, Definitions, is hereby amended to read as follows: Alarm Signal. Is an audible or visual signal or other device indicating the existence of an emergency fire condition. Audible devices maybe horns, chimes, speakers or similar devices. Voice alarms and pre-recorded messages shall be approved by the Chief. Sound pressure level of fire evacuation signals shall be no less than 15 dbA above ambient noise levels or 5 dbA above the maximum noise level lasting 60 seconds or more. Alarm System. Is a combination of approved compatible devices with the necessary electrical inter-connections and energy to detect smoke or fire conditions, and produce an alarm signal in the event of system activation. An alarm system shall be installed in an approved manner and shall conform to the following standards with respect to the type of fire alarm system; 1. National Fire Protection Agency (N.F.P.A.) Standard 72, 2002 edition. National Fire Alarm Code. 2. N.F.P.A. 90A, 2002 edition, Air Conditioning and Ventilation Systems. 3. N.F.P.A. 90B, 2002 edition, Warm Air Heating and Conditioning • Systems. 4. N.F.P.A. 13, 13D, 13R, 2002 editions, Installation of Sprinkler Systems. 5. N.F.P.A. 14, 2003 edition, Standpipe Systems. 6. N.F.P.A. 96, 2001 edition, Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equipment. 7. N.F.P.A. 101, 2003 edition, Life Safety Code. 8. N.F.P.A. 17A, 2003 edition, Standard for Wet Chemical Extinguishing Systems SECTION 907.1.1 - CONSTRCTION DOCUMENTS: 907.1.1, Construction documents, is hereby amended as follows: Delete entire section and replace with the following: Construction documents for fire alarm systems shall be submitted on reflected ceiling plans for review and approval prior to system installation. A minimum of/. inch per foot scale is preferred. CAD plans on 1/8 inch per foot scale may be allowed if sufficient clarity is shown and plans are submitted in black and white. Construction documents shall include, but not limited to, all of the following: 1. A floor plan which indicates the use of all rooms. 2. Locations ofalarm-initiating and notification appliances. 3. Alarm control and trouble signaling equipment. 4. Annunciation. 5. Power connection. 6. Battery calculations. 7. Conductor type and size. 8. Voltage drop calculations. • 9. Manufacturers, model numbers and listing information for equipment, devices and materials. Ordinance No. 4, Series of 2005 11 • 10. Details of ceiling height and construction. 11. The interface of fire safety control functions. SECTION 907.1.2 -EQUIPMENT: Section 907.1.2, Equipment, is hereby amended to include the following: Listing information regarding devices, control panels, batteries, wiring, back boxes and any other associated equipment shall be included for review. Additionally, where options are available, these shall be specified by device type and specific model number. SECTION 907.2 -WHERE REQUIRED-NEW BUILDINGS AND STRUCTURES: Section 907.2, Where required-new buildings and structures, is hereby amended as follows: Every hotel, motel, apartment building, condominium building and commercial building with attached residential occupancies having 3 or more stories, or with more than 11 units, classified under the Intemational Building Code, 2003 edition as Group A-1, A-2, A-2.1, A-3, A-4, B-2, R-1, R-2, R-3 and S-2 shall have a fire alarm system installed in accordance with Intemational Building Code Standards 2003 edition, and in accordance with N.F.P.A. 72, 2002 edition. Explanatory material: While the activation of a single flow switch will annunciate sprinkler flow, it should be noted a dry valve is allowed by code to protect an area in the range offorty-five thousand feet up to limitations imposed by system areas. This is not considered adequate in terms of identifying immediate location. In respect to life-safety, particularly for firefighters responding in these areas, it is in the best interest that these areas be further protected with the installation of heat or smoke • detection devices. Additionally, these devices shall be identified with specific addresses such that firefighters may locate more readily the activated device. 1. Double action manual fire alarm pull sta#ions shall be installed at each level of each egress, behind the bar in drinking establishments, at the front desk of a hotel and at locations required by the Chief. 2. Interior common corridors shall be equipped with system smoke detectors complying with U.L. 268, installed as per the listed spacing requirements. 3. All common public areas shall be equipped with system smoke detectors complying with U.L. 268, installed as per the listed spacing requirements. Exception: Areas not suitable for smoke detectors shall be protected by heat actuated or equivalent devices. 4. Each sleeping room shall have a smoke detector complying with U.L. 268. Device location shall be centrally located. 5. Audible signals shall be annunciated to all portions of the building upon activation of any manual or automatic fire detector. Exception: With permission of the Chief, alarm signals may be initially annunciated to portions of a building provided that the fire alarm control panel is equipped so as to allow the annunciation of a fire alarm signal to the entire building by manual activation. 6. An approved voice communication system shall be installed in all occupancies so as to enable the fire department to automatically or manually give verbal instructions to occupants of the building by selected zones and by • general alert. Exception: Occupancies with combined occupant loads of less than 500 persons. 7. Basement occupancies classified as Group A-1, A-2, Ordinance No. 4, Series of 2005 12 A-2.1, A-3, A-4, B-2, R-1 or R-2 underthe Intemational Building Code, 2003 edition, with an occupant load of 10 persons or more, shall have a fire alarm system installed in accordance to N.F.P.A. and Intemational Fire Code 2003 Standards. 8. Occupancies such as nightclubs, discos, dining and drinking establishments with live music, recorded music, or other similar sound producing equipment shall have an alarm actuated shunt trip to disconnect the source of music amplification, when the building is equipped with a fire alarm system. 9. Buildings classified as R-1 or with residential occupancies ingroup A-1, A- 2, A-3, A-4 or B-2, 3 stories or more shall be equipped with a fire alarm system in accordance with NFPA 72 (2002), as amended. 10. Buildings under remodel where the fire or occupant load is increased, classified as R-1, A-2, A-2.1, A-3, A-4, B-2 or H, shall have a fire alarm system installed in accordance with NFPA 72 (2002), as amended. SECTION 907.2.1 -GROUP A: Section 907.2.1, Group A is hereby amended as follows: Delete exception eliminating manual pull stations. SECTION 907.2.1.1 -SYSTEM INITIATION IN GROUP A OCCUPANCIES WITH AN OCCUPANT LOAD OF 1,000 OR MORE: Section 907.2.1.1, System initiation in Group A occupancies with an occupant load of 1000 or more is hereby amended as follows: This section shall be amended to an occupant load of 500 persons as measured by square footage. • SECTION 907.2.2 -GROUP B: Section 907.2.2, Group B is hereby amended as follows: Manual fire alarm systems shall be installed in all Group B occupancies. Delete all exceptions. SECTION 907.2.3 -GROUP E: Section 907.2.3, Group E, is hereby amended as follows: Delete all exceptions. SECTION 907.2.4 -GROUP F: Section 907.2.4, Group F, is hereby amended as follows: A manual fire alarm system shall be installed in all Group F occupancies. Delete exception. SECTION 907.2.6.2.3 - (GROUP I-3) SMOKE DETECTORS: Section 907.2.6.2.3 (Group I-3), Smoke detectors, is hereby amended as follows: Delete all exceptions. SECTION 907.2.7 -GROUP M: Section 907.2.7, Group M, is hereby amended as follows: Manual fire alarm systems shall be installed in all Group M occupancies. Delete exception. SECTION 907.2.7.1- (GROUP M) OCCUPANT NOTIFICATION: Section 907.2.7.1 (Group M) Occupant notification, is hereby amended as follows: Delete entire section and replace with the following: Manual fire alarm systems shall not operate in lie of n au coati fire I rm st a time the buildin is occu led. The u a to c a s sy em t s g p emergency voice/alarm communication system shall not be allowed to be used for other announcements. • SECTION 907.2.8.1 - (GROUP R-1) MANUAL FIRE ALARM SYSTEMS: Section Ordinance No. 4, Series of 2005 13 . 907.2.8.1 (Group R-1 Manual fire alarm system, is hereby amended as follows: Delete all exceptions. SECTION 907.2.8.2 - (GROUP R-1) AUTOMATIC FIRE ALARMS: Section 907.2.8.2 (Group R-1) Automatic fire alarm system, is hereby amended as follows: Delete exception. SECTION 907.2.8.3 - (GROUP R-1) SMOKE ALARMS: Section 907.2.8.3(Group R- 1)Smoke alarms, is hereby amended as follows: Delete entire section and replace with the following: Smoke alarms shall be installed and be fully addressable, analog systems. They shall be monitored at a listed monitoring facility. SECTION 907.2.9 -GROUP R-2: Section 907.2.9, Group R-2, is hereby amended as follows: Item 3.The building contains more than 11 dwelling units or sleeping units. Delete all exceptions. SECTION 907.4.3 - (MANUAL FIRE ALARM BOXES) COLOR: Section 907.4.3, (manual fire alarm boxes), Color, is hereby amended as follows: Delete section in its entirety and replace with the following: Manual fire alarm boxes should be of contrasting color to the background on which they are mounted. SECTION 907.12 -DUCT SMOKE DETECTORS: Section 907.12, Duct smoke detectors is hereby amended as follows: Delete all exceptions. • SECTION 907.15 -MONITORING: Section 907.15, Monitoring is hereby amended as follows: Delete all exceptions. 10-1-6: AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE: The following amendments are hereby made to the International Mechanical Code, 2003 edition: SECTION 101.1- TITLE: Section 101.1, Title, is hereby amended as follows: These regulations shall be known as the Mechanical Code of the Town of Vail, hereinafter known as "this code". SECTION 101.2 -SCOPE: Section 101.2, Scope, is herby amended as follows: Delete exception 1 and 2 in their entirety. SECTION 106.5.2 -FEE SCHEDULE: Section 106.5.2, Fee Schedule, is hereby amended as follows: The construction fee schedule for the Town of Vail shall be on file and maintained in the office of the Community Development Department. SECTION 106.5.2 -FEE REFUNDS: Section 106.5.2, Fee refunds, Item 2 and Item 3, is hereby amended as follows: 2. Not more than 80% of the permit fee paid when no work has been done under a permit issued in accordance with this code. Item 3. Not more than 80% of the plan review fee paid when an applicant for a permit for which a plan review has been paid is withdrawn or canceled before any plan review effort has been expended. • SECTION 701.1.1- UNUSUALLY TIGHT CONSTRUCTION: Add Section 701.1., 1 Unusually Tight Construction, All habitable buildings within the Town of Vail Ordinance No. 4, Series of 2005 14 jurisdiction shall be considered unusually tight construction. SECTION 702 -INSIDE AIR: Section 702, Inside Air, is hereby amended as follows: Delete this section in its entirety. SECTION 704 -COMBINED USE OF INSIDE AND OUTSIDE AIR (CONDTION 1): Section 704.1, Combination of air from inside and outside, is hereby amended as follows: With approval of the building official, this section shall apply only to appliances located in confined spaces in existing buildings not of unusually tight construction. SECTION 705- COMBINED USE OF INSIDE AND OUTSIDE AIR (CONDITION 2): Section 705.1, General, is hereby amended as follows: With approval of the building official, this section shall apply only to appliances located in unconfined spaces in existing buildings of unusually tight construction. SECTION 802.7- SUPPORT OF VENTS: Section 802.7, Support of vents, shall hereby be amended as follows: Enclosure and Support of Vents. All portions of vents shall be adequately supported for the design and weight of the materials employed. All portions of venting systems which extend through occupied and storage spaces shall be enclosed to avoid contact or damage to the installation. SECTION 903.3 - UNVENTED GAS LOG HEATERS: Section 903.3, Unvented gas log heaters, shall hereby be amended as follows: Unvented gas log heaters are prohibited. • 10-1-7: AMENDMENTS TO THE INTERNATIONAL PLUMBING CODE: The following amendments are hereby made to the International Plumbing Code, 2003 edition: SECTION 101.1- TITLE: Section 101.1 Title, is hereby amended as follows: These regulations shall be known as the Plumbing Code of the Town of Vail hereinafter referred to as "this code.° SECTION 101.2- SCOPE: Section 101.2, Scope, is hereby amended as follows: Delete Exception 1 and 2 in their entirety. SECTION 106.6.2 FEE SCHEDULE: Section 106.6.2, Fee schedule, is hereby amended as follows: The construction fee schedule for the Town of Vail shall be on file and maintained in the office of the Community Development Department. SECTION 106.6.3 FEE REFUNDS: Section 106.6.2, Fee refunds, Item 2 and 3 are hereby amended as follows: Item 2. Not more than 80% of the permit fee paid when no work has been done under a permit issued in accordance with this code. Item 3. Not more than 80% of the plan review fee paid when an applicant for a permit for which a plan review has been paid is withdrawn or cancelled before any plan review effort has been expended. SECTION 412- FLOOR AND TRENCH DRAINS: Section 412, Floor and Trench Drains, are hereby amended by adding the following subsection: 412.5, Mechanical • Rooms, For heating or hot-water boiler applications, the boiler room shall be Ordinance No. 4, Series of 2005 15 • equipped with a floor drain or other means suitable for disposing of the accumulation of liquid waste incidental to cleaning, recharging and routine maintenance. SECTION 606.2- LOCATION OF SHUTOFF VALVES: Section 606.2, Location of shut off valves, Item 1, is hereby amended as follows: On the fixture supply to each plumbing fixture other than bathtubs, showers and concealed wall mounted faucets in one and two family residential occupancies, and other than in individual guestrooms that are provided with unit shutoff valves in hotels, motels, boarding houses and similar occupancies. SECTION 904.1 -ROOF EXTENSION: Section 904.1, Roof extension, is hereby amended as follows: All open vent pipes that extend through a roof shall be terminated at least 12 inches above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent shall be run a least 7 feet (2134mm) above the roof. SECTION 904.2 -FROST CLOSURE: Section 904.2, Frost closure, is hereby amended as follows: Every vent extension through a roof or wall shall be a minimum of 3 inches (76mm) in diameter. Any increase in size of the vent shall be made inside the structure a minimum of 1 foot (305mm) below the roof or inside the wall. 10-1-8 AMENDMENTS TO THE INTERNATIONAL FUEL GAS CODE: The following amendments are hereby made to the International Fuel Gas Code, 2003 edition: • SECTION 101.1- TITLE: Section 101.1, Title, is hereby amended as follows: These regulations shall be known as the Fue! Gas Code of the Town of Vail, hereinafter referred to as "this code". SECTION 101.2- SCOPE: Section 101.2, Scope, is hereby amended as follows: Exception 1 & 2 is deleted in their entirety. SECTION 106.5.2- FEE SCHEDULE: Section 106.5.2, Fee schedule, is hereby amended as follows: The construction fee schedule for the Town of Vail shalt be on file and maintained in the office of the Community Development Department. All work regulated by the Fuel Gas Code shall be subject to fees as designated in the construction fee schedule for mechanical permits. SECTION 106.5.3- FEE REFUNDS: Section 106.5.3, Fee refunds, Item 2 and 3 is hereby amended as follows: Item 2. Not more than 80% of the permit fee paid when no work has been done under a permit issued in accordance with this code. Item 3. Not more than 80% of the plan review fee paid when an applicant for a permit for which plan review has been paid is withdrawn or canceled before any plan review has been expended. SECTION 303.3- PROHIBITED LOCATIONS: Section 303.3, Prohibited locations, is hereby amended as follows: delete exception 2 and 3 in their entirety and renumber exception 5, number 3. • SECTION 303.4- PROTECTION FROM PHYSICAL DAMAGE: Section 303.4, Protection from physical damage, is hereby amended as follows: Appliances shall Ordinance No. 4, Series of 2005 16 not be installed in a location where subject to physical damage unless protected by substantial barriers approved by the building official. SECTION 304.1- GENERAL: Section 304.1, General, is hereby amended as follows: Air for combustion, ventilation, and dilution of flue gases for gas utilization equipment installed in buildings shall be provided from the outdoors. With prior approval from the building official, the methods prescribed in section 304.7 may be used in existing buildings. SECTION 304.5- INDOOR COMBUSTION AIR: Section 304.5, Indoor combustion air, is hereby amended as follows: Delete this section in its entirety. SECTION 305.6- CONSTRUCTION AND PROTECTION: Section 305.6, Construction and protection, is hereby amended as follows: In all occupancies other than R-3, boiler rooms and furnace rooms shall be protected as required by the International8uilding Code. in R-3 occupancies, rooms containing a boiler, central heating plant or hot water supply boiler in excess of 400,000 Btu per hour input shall be separated from the rest of the building by not less than 1-hour fire-resistive construction on the room side of the heating equipment. Opening protection shall be obtained by use of a tight fitting, smoke-and draft-control, self-closing assemblies having afire-protection rating of not less than 20-minutes. All spaces containing fuel- fired equipment located in under-floor (crawlspace) and above-ceiling (attic) areas shall be separated from the rest of the building by not less than 1-hour fire-resistive construction on the space side of the heating equipment regardless of Btu input. • Opening protection shall be obtained by use of a tight fitting, smoke-and draft- control, self-closing assemblies having afire-protection rating of not less than 20- minutes. All under-floor and above ceiling spaces shall also be detected and protected in accordance to Vail Fire Department standards. All mechanical rooms shall be provided with a floor drain as required by the Plumbing Code of the Town of Vail. SECTION 404.14.1- LIMITATIONS: Section 404.14.1, Limitations, is hereby amended as follows: Plastic pipe shall be installed outside underground only with a minimum depth below finished grade of 18 inches. Plastic pipe shall not be used within or under any building or slab or be operated at pressures greater than 100 psig (689 kPa) for natural gas or 30 psig (207 kPa) for LP-gas. SECTION 406.4.1 TEST PRESSURE: Section 406.4.1, Test pressure, is hereby amended as follows: This test shall include an air, carbon dioxide or nitrogen pressure test, at which time the gas piping shall withstand a pressure of not less than 10 psig (69 kPa). Forwelded pipe and for piping carrying gas pressure exceeding 14 inch water column, the test shall be at least 60 psig (414 kPa). SECTION 406.4.2- TEST DURATION: Section 406.4.2, Test duration, is hereby amended as follows: Test duration shall not be less than 15 minutes for threaded pipe. For welded pipe and piping carrying gas pressure exceeding 14 inch water column, the duration shall not be less than 30 minutes. SECTION 501.8 EQUIPMENT NOT REQUIRED TO BE VENTED: Section 501.8, • Equipment not required to be vented, shall be hereby amended as follows: Delete item 8, Room heaters listed for unvented use and renumber items 9, 10 and 11 as 8, Ordinance No. 4, Series of 2005 17 9, and 10. SECTION 603 (IFGC) LOG LIGHTERS: Section 603.1, General, shall hereby be amended as follows: Log lighters shall be prohibited to be installed in the Town of Vail. SECTION 621 (IFGC) UNVENTED ROOM HEATERS: Section 621, Unvented room heaters, shall hereby be amended as follows: Delete this section in its entirety. 10-1-9 AMENDMENTS TO THE NATIONAL ELECTRICAL CODE: The following amendments are hereby made to the National Electrical Code, 2002 edition: A. All electrical wiring in Groups A, B, E, F, H, i, M and S occupancies as defined in the International Building Code, shall be encased in conduits, raceways, or an approved armor. All wiring in Group R occupancies shall be encased in metal conduits, raceways, or an approved metal armored cable to the circuit breaker box for each unit. No aluminum wire or copper clad aluminum wire smaller than size 8 will be permitted within the Town. B. Persons engaged in the installation of remote control, low energy power, and signal circuits as defined in article 720 and 760 of this code, need not be licensed themselves pursuant to Title 12, Article 23, Colorado Revised Statutes, nor work under the supervision of such licensed electricians; however, all such persons shall register with the State Electrical Board. Proof of registration shall be produced by the registrant and an application for contractor registration shalt be provided to the Town of Vail Fire Marshal for review in accordance with the Town Code, section 42- 7. C. All such installations of remote control, low energy power and signal systems are subject to the permits and inspections set forth in 12-23-111 (24) C.R.S. Accordingly, all installations of remote control, low energy power and signal systems must be performed in accordance with the minimum standards set forth in the National Electric Code. 10-1-10: COPIES OF CODES AVAILABLE: Copies of all the codes adopted by this Chapter and all amendments thereto shall be available for inspection at the office of the Town Clerk. 10-1-11: PENALTIES: A. Any person who violates any of the provisions of the Codes adopted by this Chapter or fail to comply therewith, or who violates or fails to comply with any order made thereunder, or who builds in violation of any detailed statements, specifications, or plans submitted and approved thereunder, or any certificate or permit issued thereunder, or within the time fixed therein shall be guilty of a ' misdemeanor and subject to penalty as provided in Section 1-4-1 of this Code. The imposition of a penalty for any violation shall not excuse the violation or permit it to continue; and all such persons shall be required to correct or remedy such violation or defects within a reasonable time, and each day that the prohibited conditions are maintained shall constitute a separate offense. B. The Town may maintain an action for damages, declaratory relief, specific Ordinance No. 4, Series of 2005 1$ performance, injunction, or any other appropriate relief in the District Court in and for the County of Eagle for any violation of any of the provisions of this Chapter. (1997 Code: Ord. 25(1991) § 6) The building codes adopted in this ordinance shall be effective for all building permit applications received by the Town of Vail, Community Development Department, Building Safety & Inspection Services, after January 1, 2005. Section 2. The building codes adopted by this ordinance shall be effective for all building permit applications received by the Town of Vail, Department of Community Development, Building Safety and Inspection Services, on or after January 1, 2005. Section 3. If any part, section, subsection, sentence, clause or phrase of this ordinance is for any reason held to be invalid, such decision shall not effect the validity of the remaining portions of this ordinance; and the Town Council hereby declares it would have passed this ordinance, and each part, section, subsection, sentence, clause or phrase thereof, regardless of the fact that any one or more parts, sections, subsections, sentences, clauses or phrases be declared invalid. • Section 4. The Town Council hereby finds, determines and declares that this ordinance is necessary and proper for the health, safety and welfare of the Town of Vail and the inhabitants thereof. Section 5. The amendment of any provision of the Town Code as provided in this ordinance shall not affect any right which has accrued, any duty imposed, any violation that occurred prior to the effective date hereof, any prosecution commenced, nor any other action or proceeding as commenced under or by virtue of the provision amended. The amendment of any provision hereby shall not revive any provision or any ordinance previously repealed or superseded unless expressly stated herein. Section 6. All bylaws, orders, resolutions and ordinances, or parts thereof, inconsistent herewith are repealed to the extent only of such inconsistency. This repealer shall not be construed to revise any bylaw, order, resolution or ordinance, or part thereof, theretofore repealed. INTRODUCED, READ ON FIRST READING, APPROVED, AND ORDERED • PUBLISHED ONCE IN FULL ON FIRST READING this 1S` day of February, 2005, and a public Ordinance No. 4, Series of 2005 ~ 9 hearing for second reading of this Ordinance set for 6:00 pm on the 15~' day of February, 2005, in the Council Chambers of the Vail Municipal Building, Vail, Colorado. Rodney E. Slifer, Mayor ATTEST: ~ ~ r ,,_,k6rel~ Donaldson, Town Clerk INTRODUCED, READ, ADOPTED AND ENACTED ON SECOND READING AND ORDERED PUBLISHED in full this 15T" day of February, 2005. v ~ 7 • Rodney E. Slifer, Mayor Attest: ~ 1 rte. f ` Lorelei Donaldson, Town Clerk • Ordinance No. 4, Series of 2005 20 ? y /r ~~~p . ~ ~ 7 ~ ~ v ~ ~ N O O. Q ~ Q " y ° r.. r: ~ G ~ i'' - N ~ q) cpd O y ~ ~ ~ ~ ~ ~ ~ y ° ~ ~ C y t'`~ ~ ai ° 3 cd ¢ c6 < ~ N i.C y C3+ 0^ ~ c'~d ~C3 C W ~ c'a O v G ~ ~ ? ~ $ `T' c~ N N ecS ° d ~ ~ ~ .Q ~ ~'a O ~ W c°r 4? ° ~ 5.G' G Ny G N 7 1. ~ p 'b? ~ ~ ~ N ~ d ~ ~ ~ ~ id p~ ~ ~ N ~ 6a "O F H E N 7 ceS ~ N U "C~ y N~QO ~ ~ ~ 3 w ~ ~ ,~xy G Y co A ~ t ~ ~ a ~ C~, ~ Q' c' eS 3 ~ A 7 "~O r C~ r/' at « N e f + cn N ~ 3~'~~~nnv a ~ ~ ~ ~ o N ~ Y O ~ H ~ c bn ~ 7 c ~ ~ 'fl F" ~ ~ ~ U Tha Dsllr Claulllsds 970.845.9937 / vaildailv.com Tuesday. February 8. 2005 - Peas B4F ~ ~i ~ v~T 9 t.:; K ~ ~ r. ~ i ORDINANCE NO. 4 SERIEIIS OF 2005 AN ORDINANCE REPEALING AND REENACTING 10-1 3 AMENDMENTS TO INTERNATIONAL SECTION R301.2 4 FLOODPLAIN CONSTRUCTION nrgulati+tl under a natii molly ruCOgnizaU standard in W CHAPTER 10-1, OUILDING CODES. VAIL TOWN BUILDING CODE. Section 30124 Floodplain cpnslrucnnn is hereby upon any building, slruclure Or premises' ni CODE ADOPTING BY REFERENCE THE 2003 The lOtiowing amandmorns era nereby made to the mended as follows. Delete section In ns entirety antl specifically rnonnOned m rttic rode. br be defective nr • EDITIONS OF THE INTERNATIONAL BUILDING CODE. International Bantling Code, 2003 edition. replace' wnh Bonding and Siructurna cnnslructetl In unsafe sn es to rraala a hazard. Ina CDlel is authorized INTERNATIONAI RESIDENTIAL CODE. Ilootl hazard areas are suDleci In mCtlOn 1221-i OI the In Serve upon the owner nr the person having control nl INTERNATIONAL FIRE CODE, INTERNATIONAL SECTION 101 4 REFERENCED CODES Secllon Vail town Cntle Ih¢ property a wntlen nonce to repair or altar as MECHANICAL CODf INTERNATIONAL PLUMBING 101 4. Relerencetl Cotles, is hereby amentletl as +w;ssary and shall nMily any nlher aufhunly enlorcmG CODE, INTERNATIONAL FUEL GAS CODE. lollOws The other codes lisletl in 101.4.1 through SECTION - R3038 REOtIIRED HEATING. Section rOUes regulating 5urfl equipment Tne Cniel is INTERNATIONAL ENERGY CONSERVATION CODE, 101.4 7 and relarencetl elsewhere in this cotle shall not 303 B. Requvetl healing, Is hm¢by amended by adding auNUrizotl to affix a r nndemnahon lag prohibiting the 2002 EDITION OF THE NATIONAL ELECTRICAL be consideretl part of this cotle, unless specifically Ne following. Minimum winter tlesign temperature is - use Ihere0l until such repairs or alterations are made CODE. AND WITH REGARD TO THE ABDVE- adnplon 2D' F Heal Inv calculations .shall he required for all Wh¢n affixed, wch IaV shall only ha removed by Ina DESCRIBED CODES. ADOPTING CERTAIN tlwalling units order ul Ih0 Chiral when the hazartl to which the ortler APPENDICES, SETTING FORTH CERTAIry SECTION 105 1 I ANNUAL PERMIT Delete section in pertain:: has boon aliminatetl in an approved manner AMENDMENTS THERETO AND SETTING FOR its ennraty SECTION R3039 HEATING EQUIPMENT ROOMS Until remuvud, that starts nr Uevice which has caused DETAILS IN REGARD THERETO. Adtl Section R303 9, Healing pquipmeni rooms, as the hazard shall not be used or he permitted In de SECTION 105 2 WORK EXEMPT FROM PERMIT. follows In R-3 occupancies, rooms containing a boiler, used WHEREAS. publication nl the 1997 Uniform Builtling Section 1052, Wok exempt Irom permit, is nereby enirel heating plant or hot water Supply boiler M i Cotln IL1BC), es curranlly atlnpien by Iha Town of Vail. amentletl as follows c of 400.000 Btu per hour maul shall Du Whan soon an apparent structural hazard is caused by has bean disCOntinued. antl item 6 Decks, patios, sitlewalks antl dnvaways not separaletl from the rest 01 the building by nM IeSS than the faulty installaiiOn, operalipn or rtialipnction of any p~ re Than 30 Inches above gratle and not over any 1 ~nour fire-resistive construction on the room side of the Tha items nr tlevires lisletl in Inis section, the Chief shalt WHEREAS. the 2003 Etlrtions of the International basement or storage Oelow and which are not pert of healing equipment Opening prolnclion shall ba medialely nobly the building olhcal to investigate Builtlinq cotle (IBC), the Ini¢rnallOnal gesidenlial cotle an accessible route oblainetl by use of a light IiHing, smoke and t/raft- uch hazard anA cause sorb hazard IO De abatetl as (IRC), lee International Fire GotlP (IFC). the Item 11 Swings antl other playgrountl equipment conlrol. Sell-closing assemblies having a Ina Drolection requirutl by In¢ bantling code Internatronal Macnenroal GOtle (IMC), the lnlernauonai renng of not less than 20-minutes All Spaces Plumbing Code (IPC), Iha International Fuel Gas Cntle SECTION 106 2 SCHEDULE OF PERMIT FEES. onlaining brat brad equipment localen in under-floor SECTION 1 115 -STOPPING USES. EVACUATION (IFGC). the International Energy Conservation Code Section 1062, Schetlule of parmil lees. is amentletl as (crawlspace) antl above-Ceiling (albs) areas shall be ArW serlinn 111 S Stopping a evacuation Tne (IECC) and the 2002 Etlliion OI Iha National Eleclrir, billows. The construction fee schetlule for the Town of separatatl Irom the rest M the building by not lass than Ghiel is authnnzed t0 ortler ens Operation 0 Cntle (NEC) have been publlshetl, antl Vail Shell be on Irle antl maintainetl in [he office of the 1-hour fire-resisnva cnnsiruC.lipn nn Rte space side M slopped Or Ne evacualinn of any promises, builtling Or Communiry Development Department tea heating equlpm¢nl regardless of Btu input vehicle or pomnn Ih¢rebl which is a hie na:artl WHEREAS. the Bonding antl Fve Cntle Board Of Opening protection shall ba ohlainetl by use Of Bligfn appeals M the Town of Vail has reCOmmantletl SEC11pN 108.3 - BUILDING PERMIT VAWATION toting, smoke-and tlraft conlrol, selhclosing assemblies SECTION 202 - F FALSE ALARM Section 202. Fels dnption of the Interneiional Cotles. as set lorlh in this Section 108.3. 8unding permit valuation, is hereby having afire-protection rating OI not less Inan 20 alarm Is hereby amentletl as IollOws Delete False ordinance, antl has submitted its recommendation to mantletl as follows The valuation of building permits minutes. All untler floor antl a0ovn railing Spaces Shall alarm definition antl replace with Iha following The Thu Vail Town Council antl n the Town of Vail Shall be basetl nn the most recent have Smoke nr heal tlelecli0n antl aulomalic fire ariivation of a device or transmission of a alarm nsl figures. per square IOOI as shown in the sprinklers in accortlanc0 10 Vail Fire Daparimant signal. indn:anng an emergency exrsis nantl/Or WHEREAS, me Vail Town Council finds Thal Iha International Handing Safety Journal publishetl by the 5lantlards. essitaling response by the Vail Police Department prpposetl amendments furihar the tlevelopmeni International Code Council, a Copy OI which Shall be on or~rtlie Van Fire Department. where n0 emergency oblertives of the Town of Vail, antl file in the Department of Communiry Development of SECTION R305 CEILING HEIGHT. Section R30S 1, exists the Town of Vail. All construction shall be tleemetl Exception 2, Is hereby amended by deleting this WHEREAS, the Vail Town Council finds that the "gpotl" exception in its entirety SECTION 702 F FIRE CODE OFFICIAL Section 202 F antlmeWl~S pro ale Iha health. Safely, ingots. antl Frre f.Gde Official, r5 hereby amentletl da (dlpw5 general Ifare f the Town antl promote the SECTION R310 -EMERGENCY ESCAPE AND RESCUE Substitute Fve marshal for Fire cotle official OOrtlinetetl antl harmpnpus tlevelopment of the Town SECTION 110 -CERTIFICATE OF OCCUPANCY OPENINGS: Secllon R310 1, Emergency escape antl e mamnar that conserves antl enhances its natural Season 110.1, Use and occupancy, is hereby amended reSCUe requiratl, is hereby amentletl as follows. First SECTION 305 5 -GAS sAETERS AND PIPING. Atltl ant and its established character as a resort as-{dllpws. No building or slruclure shall be usetl or paragraph, lirsl sentence amentletl as follows. section 305 5. Cas metefy antl piping, M follows and resitleniial rommuniry of the highest quality ocpupied, and no change In Ina existing occupancy Basements antl every sleeping room shall nave at lees) AbnvO ground gas melera, legulelors. antl piping shall claBaiLCefion of a building pr structure Or poreon pee openeble emergency escape antl rescue opening he prtnectetl Irom tlamage by ice or srww, and if NOW, THEREFORE BE li ORDAINED BY THE 70WN thereat shall be made until Tne builtling official has expnsetl to vehicular tlemege tlue to proximity to COUNCIL OF THE TOWN OF VAIL, COLORADO, THAT issuetl a certificate of occupancy Therefor as providetl SECTION R403 1 4 i FROST PROTECTION. Section alleys, driveways or parking areas. Shell be protects~ herein Exception. Atldltions. alterations or repairs to R403.1.4.1, Frost protection, is hereby amentletl by Irom such damage in accortlance with section 312.1 0l Section 1 Chepler 10 1, Building Cotles. Vail Town existing Group R. Division 3 antl Group U tleleling this section In its entirety and replacing with Inis cotle Cntle, is hereby repealetl antl reenacletl to reatl as Occupancies. Issuance of a ceruhcaie of occupancy Tne lollowing Foundation walls. piers end Other loll[rvs shall not be construed es en approval of a violehpn of permanent supports shall be protected irtnl host by SECTION 50B 6 5 CLEAR SPACES AROUND CHAPTER 1 the prOVisbns of this code Or of other brtlinanpe5 of the Droviding e m nrmum tlapth of 4P" me95uratl from HYDRANTS Section 506 5 5, Clear spaced arountl juri5tliclion. Certificates presuming to give euMOrity to finishetl grades to the bottom of the fooling. Where hydrants, shell nereby be amentletl as tplloWS Delete BUILDING CODES violate or ranrel the provisions of this cotle or other applicable, the tlapth of the footing shall also conform entire Section and replace with. A char antl SECTION urduiancas Of Nc lunsdlrtion sl sell nn1 ha valid l0 Sections A403 1 4 1 through R403 1 A 7 unoDetrucletl space shell by mamtainetl around a Lm 10-1-1 Preamble hydrant with the lollOwing minimum distances stool 10-1~2 Cotles Adopted By Ralerence SECTION 1025 ~ EMERGENCY ESCAPE AND SECTION 8403 2 FOO T IN(~S FUR WOULD t.. tool, rear 4 iret sitles ]leer Frt¢ hytlranis shall 10-1-3. Amentlmenis to International Builtling Coda RESCUE Section 1025.1, General, s hereby FOUNDATIONS Section R403.2 Frntings for wootl be instelletl antl mamleined fo provide a minimum of 36 101-4. Amantlments to Infernalional Resitlential mantled as lollOws. Exception 18 4, delete in iheu loundalions, Is hereby amentletl by adding the nches of clearance between the Canters of Hie WII~. Code entirety, following. Fountlalions shall be tlesignetl by a raps antl finish gratle 5lantlards sal Iorih by leer 10.1 ~5 Anlentlments lO International Fire Cntle regisferetl Colnratlo Engineer antl approved by the agencies inclutling the water tlisvici, may De 10-1.6 Amantlments to Infernalional Mechanical cotle SECTION 1608 SNOW LOADS Section 1608 2, Ge0lecnnlcal Engineer relerencad antl enlaced providing (tie most rastricbve t0-1-7 AmantlmentE to International Plumbing Coda Grountl snow loads. is hereby amentletl as follows shall apply 10-1-8 Amendments tO lnlernetional Fuel Gas Code Designs for roof Snow tootle shall be as follows. Roof SECTION R403 3 -FROST PROTECTED SHALLOW • 10-1-9 Amendments to National Elecrical Cntle pitches of less Than a 4.12, shall be tlesignetl to carry FOUNDATIONS. Section R403.3, Frost proecteU SECTION 610 -COMMERCIAL KITCHEN HOODS 10-1-10. Copies of Cotles Available a 100 pountl per square Idol (psi) snow load antl root shallow fountlatinis, is hereby amentletl by adtling the Secllon 610. Commercial Kitchen HontlS. shall hereby 10-1-11' Penalties pitches of 4.12 antl greater shall De tlesignetl to tarry following: Fnuntlations shall be tlesignetl by a D¢ amentletl as follows Delete enlve section in ns an BD pountl per square foot (pets snow loatl There is regisferetl GOIOratlO Engineer and apprnvetl by (tie entirety and replace with 10-1-1. PREAMBLE no allowance Inc pitch retluction nor Is there a Geoiechnical Engineer The Charter of the Town of Varl antl the statutes of the requirement fo increase tootling due to wind, valleys or SECTION 610 1 -VENTILATION HOOD AND DUCT Stale of Colorado provide sties slantlartl codes may be type of roof Covering. Any motli(icalion for snow loatl CHAPTER 12 -CHAPTER 42 Delete in (heir entirety SYSTEMS SeCUnn 610 1 Venillation Hoed antl Ducl atlnpted by reference wah amendmenisi antl the Town tleegn shell be accomptishetl using section 104 1 t. antl reference other rotles adopletl by refeencv Systems A venthaling noon antl duct system shell De of Vail wishes to atlopi Iha 2003 etlitions OI the respectively providetl in accortlance wile Imernatronal McChanical Inlernationai Building Cntle, Ne International SECTION 34031- E%ISTING BUILDINGS OR Cntle Inr commercial type food heai~prOge55ing Resitlential cotle, Ne Inlernahonal Fire cotle, the STRUCTURES SeclrOn 3403.1, Existing buildings or 10-15. AMENDMENTS TO THE INTERNATIONAL FIRE equipment that produces greaxe laden vapors International Mechanical Code, the International stiucWres, is here by a endetl by atltling Inn CODE. Plumbing cotle, the International Fuel Gas cotle, the following Every contlominium association or owner of a The following apwndrtrenfs are hereby made l0 ttie SECTION 610 1 2 -FIRE E%iINGUSHING SYSTEMS International Energy Conservation Code. antl the 2002 Duiltling or slruclure built before 1991 shall within 18 Inlernahonal Fire Cntle, 7003 etlnion Atltl B¢chnn 610 1 2 Fire~Extinguisning Systems atlilipn OI the National Electric cotle months nl the atloplion of this coda, provitle to the Where a Type I hnotl is requrr¢tl in De inslilletl a fire Town of Vail a copy of a Fire Posk Assessment (ERA). SECTION 103 DEPARTMENT OF FIRE PREVENTION exliiiguisniny system shall also be requvetl 10 7 ~7 CODES ADOPTED BV REFERENCE. Ttie FRA Shall be developed by tea Town of Veil's Fne Section 103. Department Of Frre Preveininn shall be Prevention antl Fire Marshal's Office The FRA shall hereby amentletl as follows Title shall be changed in SECTION fi107 ~ WHERE REQUIRED Section 6102 A BuilUing GndO. Tha Infernalional Bwlding cotle, Contain necessary elements and De in suificieni detail Foe Prevention Bureau. Where Requir¢A. Approved auinmatic hie 2W3 etlnion, inclutling Appendiz Chepler J antl the as In provide a basis for tletermining applicability of extinguishing systems shall De provitled for ins Intarnafional Resrtlentiel cotle, 2003 edition, inclutling relroaclive application of cotle provisions Minimum SECTION 103 1 -GENERAL Secfinn f03 1, General p.olecfion nl crsnmercial type cooking egwpment Appendix G, Is hereby atlnpted by reference The Components shall comply with the atlnpted Town of Vail shall hereby be amentletl as lollpws. Delete section in Inlernati0nal Builtling cotle, 2003 etlltion and Iha Stantlartls its entirety antl replace with A hie prevention bureau SECTION 610.2.1 -TYPE OF SYSTEMS Atltl Section International R¢sltlential Code. 2003 edition, Is established within the fire tlepartmenl untler Ina 61021. Type n/ Systems The system usetl for tea publishetl by the International cotle Counpl, 4051 Bwldings subject 10 Inis req uvemenl tlvection of the Chief shall consist of hie tleparimenl protection nl cnmrtrerciel type cOOking equipment shoo West FloSamoor Roatl. Country Club Hills. II 60d7B include personnel assignetl thereto Dy Iha Chief Tne function he either a system lisletl for appticauon wittl such 5795 Group A, A. E F H, 1 antl 5 of (his bureau Shall be to assist Tne Cniel in the equipment or an automatic lira exbngui5hing system Group M with more than one llmr, atlminisiralion antl enforcement 01 the provisions of this that is specAically tlesignetl for such application B Fre Code. The International Fire Code, 2003 etlrtion, Group R-1 antl R-2 with more than Iwo stories, more cotle Systems inslalletl shall meet nr exceetl U L 300 is hereby adopletl by reference The Inlernatinnal Fire than 12 accgrtlmbtldiion units, or tlwelling units. requirements. antl shall ba installed in accprtlanCe with Cntle. 2003 etlition, is publlshetl by the International Group R-3 over Mree stories, exclutling Group R-3 SECTION 103 1 I - FIRE MARSHAL Atltl Section Manufacturers spacilicatipns antl mstructipn5 Cntle CounGl. 4051 Wesl Flossmoor Road, Country regulaletl by the International Restlentiel cotle, 1031 1, Fire Marshal. The Chief is aulhpriz¢tl to f Club Hills. II 604785795 Any building or slruclure more Inan SOI)0 square feet of tleaignate a member of the fire tlepartmenl to exercise SECTION 610 2 2 ~ E%1ENT OF PROTECTION Adtl Floor area, per floor [he powers and perform the duties of fire prevention section 610 2 7 Extent of protection. C. Mechanical cotle The International Mechanical Any builtling or sluclure where all points of the Firs[ engineer as set forth in this cotle Tne fire prevention The aulOmalic hre axtingursning system used to protect cotle, 2003 etlition. Inclutling Appendix A, is hereby story are mo a than 150 feel hem a single point of engineer may also be known as the (ire marshal antilalinq hinds and tlucls antl rooking apPlianCes atlnpted by reference Tne Infernalional Mechanical approved firertleparlment access snail be installed In inclutle conking surfaces, tleap Ial Coda. 7003 edition, Is publisnetl Dy Iha International SECTION 104.1 1 -FIRE PREVENTION BUREAU AND livers gndtll¢s. upngnl nr0rlers rnarbroilers. rangy Cone Council, 40.51 West FlOSSmoor Roatl, Country Upon submission of lee FRA, the Town will evaluate Tne PEACE OFFICERS. Atltl Section 104 I 1 Fire Ines antl grills PrOlernon shall also be provided for the Club Hills. II 60478-5795 esults and determine appllcabltity of relrofil provisions prevention bureau and peace oHlcers. The Chief and nrlnserl plenum space wiHiln the hootl above fillers in accnrtlance with Tne Town of Vail Design Guitlelines members of the hie prevention bureau shall have the antl exhaust duels serving ins bond Plumbing Code. The International Plumbing cotle, pnWers nl a peace office, (as detinetl per C R S 18 1- 20(13 edninn. is hereby adopted by reference Tha 10~1~4 AMENDMENTS TO INTERNATIONAL 901, 3(I) (III) in performing their Julies untler ibis code SECTION 610 2 3 -AUTOMATIC POWER FUEL AND International Plumbing cotle 2003 etliiron, rs puDhshetl RESIDIENTIAL CODE VFNTILA710N SHAFT AUU Serirpn F f0 2 3. Automaiu: by the Intarnafional Code Council, 4051 H045mOOr Tha following amantlments a ¢ nereby made to the When requestetl In d0 so by the Chief the chief of Power fuel antl venlnatipn shall Automatic lirrL Roatl, Country Club Hills, II 60478-5]95. International Resrtlential Cotler20031tlitbn police is aufhorizetl to assign such available peace extinyuishinq systems shall be inten:onneCtetl to me officers as negessary to assist the lire tleparimenl in fuel o eel supply for sinking equipment. The E Imernalional Fuel Gas Code The Irnernatianal Fuel SECTION R102 -APPLICABILITY Section R102.4, enforcing the provisions of this rode nr ~ ¢clinn shall he arrangetl In automatically soul Gas Code 2003 edition, is hereby adopletl by Referencetl Cotles antl slantlartls. Is nereby amentletl nit •alln c~nking rquipmenl anti elecincal receptacles reierenOa Tne Infernalrona! Fuel Gas cotle. 2003 by adtling Tne louowrng Reference to other codes such SECTION 1062. t INSPECTION REQUESTS Ad<I wfnc+i are located under tea hood when me system is P.tlition, is published by Tne Infernalonal Code Council, as Plumbing, Mechanical antl Electrical shall refer only Seetien 106.2 1. Insperfion requests I[ shall be Ihr aclualetl. Snutnll valves or switches shall be of a Type 4051 Flossmoor Roatl. Country Club Hills, II 60478- l0 the Currently adopletl code of shat Type. tluly of the person performing the work autt10nzetl by a that reVuires m ual npereiion to r eel HOOo 5795. parmil to no[Ily the Chief Thal Tne work is ready for nnlnation syslemn shah remain operalinnal upon F Energy cotle. The International Ener Conservation SECTION R105 PERMITS Section 105 2, Work nsp¢ction The Chief is authnnzeU In require Inat every arlivation of system. unless authnnzed t0 perform gy exempt Irom parmil. is nereby amentletl as Inllows request Inr inspection bo IrIFlU not less than onr: ¢rw ¢ by Iha Chiral Artivanon nl a aulnmaliC r~ Code 7IX13 etlilion, rs hereby atlnpted by reference working tley helorn such mspe,:tien is desiretl Sutra exlinqu Wining .system soon Van.Srtu1 an alarm to the The Infernalional Energy Conservation Cntle. 2003 Item 1 One-story Jerached accessory structures used requests may be in writing nr by lel¢phone al the option bonding !ire alarm sYStem edition, is published by Tne Inlernaiional cotle Council, as tool shetl5, Storage shetls, playhouses and similar of th0 Chief. 4051 Flossmnor ROatl. Country Cluh Hills. es provided the Moor 2rea tloes not excentl 170 CFCTON 610 2 4 - MANI)AL SYSTEM OPERATION square leas SECTION 11013 - UNSAFE HEATING OR Pdd Snclion fi10?4. Manual syslfni rrneration A G Eleciriral Code Tne Nalinnal Elecincal Code, 2002 ELECTRICAL EDDIPME NI AND STRIIGTIIRAI. earliiy arra~sibl¢ m noel n.-. ivalir,ii dcvire shall be edninn, is nereby adnpfetl by reference The National Item 5 Decks, patios. sitlewalks and dnvaways not HA2AR05 Adtl 8¢ctinn 110 1 3, Unsala heating nr iii. rallaJ ar nnlancn i with Man~,rlacturer s EI .I Cal Code s pubs sh¢tl by the. Nai noel Fre more Inan 30 ncnes abrrve grade antl not over any el¢Clr cal equ'pm t tl f 1 I I d Wh fh I r - d h 1 1. rt N EPA. 17A; • P 1 ..lion Assoc at On Inc ~ On¢ Ballerymarch Pdrk basemen) or sinrage below and whch are not Parl of Ch el deems any h y, k t ,k. t F T n f d I W .I .h I E 1 9 i. h q SY to Tha Ou cy. Ma 02269 an across tile, route tic neralnr, lurn.r y Ih . h . I I d t v t f . II tl t t h ally or elerlr r, f x[ura or any appurlnnan .a innrel r or anyih nq rr.t n ly operate f II ¢ ertr cal power s setl, Tne BZ8 - Tuesday. February 8. 2005 Tlr DtM4f ClauNhds 970.845.9937 / vaildaflv.com system shell Do connected to a stantlby power system repelr operation to take appropriate measures to avoid system smoke detectors complying with U L 268, and a visual means shall De provWed to show that the Isles elerma (activation of lire detection system under installetl as per the listed spacing regwrements. SECTION 101.1 TITLE Secuon 701.1, Title, is hereby extinquishirp system Is anerpixetl. Instructions for non-emergency circumstances). 3. All common public areas shall be equipped with amended es fdloes: Ttlese regulations shau be known operating the lire eztinpdehinp system shall De posted A lire extinguisher with B minimum rating d 2AIObc system smoke detectors complying with u.L 268, as the Mechanical Code of the Town d Veil, neremanar adjacent to manual activation devices. shell De providetl for each 400 square teal of ski shop installed as per the listed spacing requrements known as "tms Coda" repair area. Such hre extinguisher shall be equippetl Exception. Areas not suitable la smoky tletectnrs shall SECTION 610.2.5 -PORTABLE FIRE EXTINGUISHERS. with a service lag. provitletl by a licensed fire be protected by heat actuated a equivalent tlevices SECTION 701 2 SCOPE. Section 701 2. Scope, is Adtl Secuon 610 2 5, Portable lire extinguishers. A K~ protection company, indicating roar the extinguisher 4 Each sleeping room shall have a smoke tleteclor heihy amended as lollows Delete exception 1 and 2 in Class ¢xlinguisher shall be Installed wNmn 30 teal of has been serviced and/or recharged within Ifre last Complying with U L 266 Device location Shall be Theo entirety commercial food heat processing equipment as Twelve rronms centrally locatetl. measuretl along an unobstructed pain of travel in Temporary ski report operations shall not be allowed 5 Audible signals snail be annunciated to all portions SECTION 106 5 2 FEF SCHEDULE Section 10fi 5 2, acrnrtlance wim NFPA. 10 wimin the residential portions. accommotletion units, of the builtling upon acfivatron of any manual or Fee Schedule, is hereby amendetl as lollows. The • dwelling units, contlomimums or sleeping rooms of automatic fire detector Exception With permission of construction lee schedule for the Town of Vail shall be SECTION 610 3 ~ OPERATIONS AND MAINTENANCE. builtlinps. Hazardous rooms shall not allow (i.e. -boiler the Chief, alarm signals may be Initially annunciated to on hie and mainleinad In the o8ice of the Community Add Section 610 3, Operations and mainlenenr.6 Tne rooms, HVAC. electrical rooms, rooms beneath stairs, portions of a Duiltling providetl that the lire alarm Development Department vanlilatipn 9yslemi In Connection With hoods shall h0 non Ilia-retetl attics, storage rooms antl similar control panel is equippetl so as 1o allow the operated at the required rate of air movement, spaces). ennuncietion of a fire alarm signal to the entire Duiltling SECTION 106.5 2 -FEE REFUNDS: Section 106.5 2. classihetl grease fillers shall be in place when All Instasatlons and features thereof are subject to the by manual activation. Fee refunds, Item 2 and Item 3, is hereby anrended as equipment under a kitchen grease hottl is usetl. If approval d the Fire Chief end Chief Building Official. 6. An approved voice cpmmunicaton system shall be follows 2. Not more then BO% of the permit lee d grease extractors are installetl, they shall he operaletl installetl in all occupancies so as to enable Nie Ilre when no wok ties been tlone under a permit issued in when the commercial type cocking equipment is used SECTION 804 1. t - RESTRICTED OCCUPANCIES department m aummalicaNy a manually give verbal accordance wth this code Item 3 Nor more roan BD% Hoods, grease removal devices, fans, ducts antl other Section a04.1.1, Resbicled occupancies, i6 hereDy insiruplions to occupants of me building by selepmA of IhB plan review lee paid when an applicant br e appurtenances shall be cbenatl every six months, amentletl as fellows. EzceDUOn, Trees locetetl In areas zones Bnd by general alert. Exception Occupancies permit for which a plan re w has been paltl is unless otherwise approved by the Chief, In writing proteced by an approvetl automatic sprinker system with comDinetl occupant tootle of less Than 500 wimtlrawn a canceled betas Bny plan review eeort Cleanings shall be recatletl, antl records shall slate installetl In accordance with Section 901.3.1 1 or persons. 7 8esenrent occupancies clessllied ac has been expended In¢ extern, time. antl tlale of cleeninp. A slicker a 901.3 1.2 shell not be prohlbltetl in Groups R-1 and R- Group A-t, M2, A-2.1, A3, A-1, B-2. R-t a R-2 under dher mdiceting means shell be affixetl tv the hood. 2. the Inernational Building Code, 2003 edition, wim an SECTION 701.1 1- UNUSUALLY TIGHT Cleaning recortls shall De maintained on the premises occupant load of 10 persons a more, shell have a fire CONSTRUCTION. Atltl Section 701 1 I UnusuaNy Extinguishing systems sheN be serviced et least every SECTION 902 DEFINITIONS. Section 902, Definitions, alarm system installed in accatlance to N.F.P.A. and Tight Construction, All habitable Duiltlings within the six months or after activation of the system Is hereby ismentletl to reetl es lollows International Fire Code 2003 Stantlerda. Town d Veil jurisdiction shall be consitleretl unusualy Inspeatione shall De by quallliatl intlivitluals, antl a 6. Occupancies such aB nigMCluDs, tlisaos, tllninp antl IIpM construction. Cerbhcate of Inspection shall be DoM mamtametl nn Alarm Signal. Is en audible a visual signal a other tlrinking estaDlishmenls wile tlve music, receded xxi. 702 -INSIDE AIR Section 702, Insitle Air, is the premises antl forwarded to the Chief upon device indicating the ezislBnce of an emergency lire music, or other simaar swntl producing egdprttenl hereby amentled es lollows. Delete mis section in Ns completion. cmtllHgn. Autlible devices may be horns, chimes, shall have an alarm acluatetl shun) trip to tliscomect entirety. speakers or similar tlevices. Voice alarms eMl Dre- the source of music ampliflcadon, when the Duiltling is SECTION 6104 -SKI SHOP REQUIREMENTS: Atltl recadatl messages shell Da approvetl Dy me CNeI equippetl wim a hre alarm system. SECTION 704 -COMBINED 115E OF M161DE AND section 610 4. Ski Shop Requirements, SourM~lsasure level of fke evacuation siprlels allall be 9. Buildings classified as R-t or with recitlentl9l OUTSIDE A111 (CONDTIQN i): Secton T01.1, no lase Than 15 dbA above ambient nolsa levels a 5 occupancies In group A-1, A-2. A-3, A-4 or B-2, 3 C. , d sir Irom inside erld outside, is hrsroby SECTION fi10.4.1 SCOPE: Add saclion 610.41, tlbA above the maximum noise level leering 60 stories or more shall be equipped wim B lire alarm arnentlsd 8a Idkwrs Witty approval of the Duiltling Scope, es fdbws: This section shall apply to all seconds a more. system in eccortlance with NFPA 72 (2002), as pfflciel, Mla section shall eppry mly to appliances commercial operations involving the processing. amended. locetetl b cmlined spaces in existlng buildings nd of manufecturinp, repair, waxing, preparation and Alarm Syslam. Is a combination of approvetl 10 Buildings under remotlel where the hre or unususiry tight consvuctian associated lunctkxla win respect ro snow skis, stew compalWle devices with Ms necessary electrical inter- occupant loetl is increased, classified as R~ I, A-2, A- boartls. snow hoots, waUr skis, skate boards and other conneotlma antl energy to tlelect smoke or fire 2.1, A-3, A-/, B-2 or H, shell have a hre alarm system SECTION 705- COMBINED USE OF INSIDE AND equipment wim sknller leetures. amdMOr15, and produce an alarm signal in NN event of installetl In eccortlance with NFPA 72 (2002), as OUTSIDE AIR (CONDITION 2) Sedan 705.1, General, sYSIMI acMation. An elwn system shall ba mstalletl amended. is nareby amended as fosows: Wim approval d Vie SECTION 6t0A.2 -EQUIPMENT Adtl secton 610.4.2, in M approved manrlw antl shell codortn to the builtling oMCial, this section shall apply only to Equipment, as IoNOwa. All equlgnenl usetl in Tne aDOVe 1d1owMlp atantlards wile respect id Tne type d lire SECTION 807.2. t -GROUP A. Section 907 2.1. Group spolancea boated m uncoMinad spaces in existklq Operations shall De listetl by an approved agency when alarm system, q is nareby amentletl as follows: Delete exception Duiltlings c unusually pght constructon. me equipment uses heel Name a power operations eliminatlnp manual pull stations. Seitl equipment anal be meinteinatl In pootl contlition Natianel Fire Protection gpsncy (N.F PA) Stentlertl 72, SECTION 802.7- SUPPORT OF VENTS. Sectim 802.7, and used according to the menufacturer'a 2002 adifbn. National Fke Nerm Cotle. SECTION 907,2 1 1 -SYSTEM INITIATION IN GROUP Support d vela, G1ell hereby be Itmendetl es fellows: racommendativna. N.F.P.A. 90A. 2002 edition, Air Cgntlitbning and A OCCUPANCIES WITH AN OCCUPANT LOAD OF Enclosure end Support of Yenta. AN portions of vents VentileBOn Systems 1,000 OR MORE Section 907.2.1.1, System irktlatim in shall !b edequatety supported tar Tne design antl SECTION fi104.3 USAGE: Atltl saclion 610.4.3, NFPA, 908, 2002 edition, Warm Air Nesting antl Group AOCCUpancies with an occupant loatl of 1000 or walpM c me materials employed. All porlims of Usage, as follows. Heat antl flame protlucing devices Condtioninp Systems. more I5 hereby amended as follows. This section shall venting syalems which extentl Mrough occupied antl shall be used only by qualilletl personnel antl shall be NFPA. 13. 13D, 13R, 2002 etlitions, Installation of be amentled to an occupant bad of Si'Xl persons as steeps spaces snail be enclosed to avoid contact a equipped with a suileDle base or holder. Seitl Sprinkbr Systems. measured by square tentage. tlamape m me installation. equipment shell nd Da used on wOlk tables wim NFPA. 14. 2003 edition, Standpipe Systenw. combustible surfaces. N.F.P A. O6, 2001 edition, Rertrovel of Smoke and SECTION 907.2.2 -GROUP B. saclion 907.2 2, Coup SECTION 903 3 UNVENTED GAS LOG HEATERS: Grease laden Vapors Irom Commercial Cooking B is nareby amendetl as fdlowa. Manual fire alarm Secttm 90.3.3, Unvented gas kip heaters, shall hereby SECTION 610,4.4 -ELECTRICAL', Atltl section 610.4.1. Equipmera. systems shall be installed In eN Group B occupancies. ba errlerltlad as Idlows. Unvametl 9aa Iqp Malere era Electrical, as lollows: All electrical appliances, liztures NFPA. 101, 2003 etlihOn, Life SefeN Cotle. Delete all exceplione prolliltifstl. and equipment shah De kebtl by en approvetl agency N.F.PA 17A, 2003 edition, Stentlertl for Wet Chemk:el end shall ba maintained in a sale antl operahle Expnguiahirip Systems SECTION 907 2.3 GROUP E Ssclwn 907.2.3, Group 10-1-7 AMENDMENTS TO THE INTERNATIONAL manner. Non-grounded ezlension catls antl multi-plug E, is nareby aniended as lollows. Delete all PLUMBING CODE. receptacles ere strictly prohibited, SECTION 907 1.1 - CONSTRCTION DOCUMENTS. exceptons. Ths IWlawinp amendments are hereby made to me 907 1.1, Construction tlocumems, is hereby amentled International Plumbing Cotle, 2003 edtbn. SECTION 610.4.5 FLAMMABLE AND COMBUSTIBLE as 1011owe. Delete entire saclion and replace wim the SECTION 907.2.4 -GROUP F' saclion 907.2 4, Group LIOUlDS Atltl section 610 4 5, Flammable antl following Construction documents fa fire alarm F is hereby amendetl as Idkxvs A manual Ina alarm SECTION fOt 1- TITLE Section 101.1 title, is nareby combustible hquitls, as foNOwe: No more than one U S systems shall be submittetl on reflectetl ceiling plans system shall he installed in all Group F occupancies. amended es follows. These repulelions shall De krawn gallon (3.781) d Bemmeble a comWstiDle liquitl shall for review and approval prier to system installatan. A Delete exception as me Pkunbirp Cotle c the Tarn d Vail hereinaher • be Permittetl an the Premises at any time All minimum d ?Inch Per foot scale is preferred. CAD referred m ao 'tde code Ilammable liquids storetl on the premise shall ba stored plans on tre inch per foot scale may be allowetl If SECTION 907 2.6 2.3 - (GROUP I-3) SMOKE in an approvetl container in a sale arse No flammable sufficient clarity is shown and plans are submidetl in DETECTORS: Secuon 907.2 6 2 3 (Group I-3), Smoke SECTION 101 2- SCOPE Section 101 2. Scope, is or combustible hquitls shall be storetl within 25 feet of Mack and white. Consvuction documents shall include, tletectnrs, is hereby amentletl as follows. Delete ell hereby amended as follows Dvleta Exception I and 2 any open (lame or heat protlucing device capable of but not limrtetl lo, all of the following. ezceptivns. In Meir entirety igneian. 1. A Noor plan which intlicales the use of all rooms SECTION 907 2.7 - GROUP M Section 907 2.7, Group SECTION 106.fi Z FEE SCHEDULE Section 106.6.2, SECTION 610.4.6 - OPEN FLAME. Add section 2. Locations of alarm-initiating and notification M, is hereby amentled as follows. Manual hre alarm Fee schedule, is hereby amentled as fellows Tne fi 104.6, Open flame, as fellows No open Neme or heel appliances systems sheN be installetl in all Group M a:cupancies. consbuctbn fee schedule far ms Town of Vail soak oe protlucing device shall De IeN unaffentlatl while in 3. Alarm control and (rouble signaling equipment Delete exception. on file antl mamteinetl in Iha Office d the Community operation. All such devices shall be turned oft, 4. Annunciation. Development Department. tlisconnecletl or extinguished if not In Immediate use. 5 Power connection SECTION 907.2.7 1 - (GROUP M) OCCUPANT 6. Battery calculations NOTIFICATION: Secflon 907 2 7 1 (Group M) SECTION 106 6 3 FEE REFUNDS. Section 106.6.2, Fee SEC7tON 610 4 7 VENTILATION. Add saclion 7 Contluclor type antl size Occupant notification, is hereDy amended as follows. refunds, Item ?antl 3 are nerepy amendetl as follows 610.4 7, ventilation as follows All Shops in which Toxic, 6. Voltage drop calculations. Delete Bnlire section antl replace vim the (dlowing. Item 2 Not more than 80% of me permit lee paid when Nammable a poisonous gases or other vapors which 9 Manufacturers, motlel numbers and hating Manual lire alarm systems shall not operate in lieu of an work has been done under a permit issued in are potential hazards shall ba equippetl with proper Information for equipment, devices antl materials automatic fire alarm system at times the builtling is a~cortlance with Inis code. Item 3. Nol more than 80% ventilation. Said ventilation systems shall be tlesigned 10. Details of ceiling height and construction. occupied. The emergency voice/alarm communication of the plan review fee paitl when an applicant fa a Ia have the capacity of providing 1.Scfm/II2 per square 11 The interlace of hre sefaN control functions. system shell not be allowed to be used fa other permit fa which a plan review has bean Dad is 1001 o/ floor area Tnis mechanical system shall De announcements wimtlrewn or cencalled before any plan review effort provided by a memod d supply antl exhaust air. The SECTION 907 1 2 - EQUIPMENT Section 907 t 2, has been expendetl. amount of supply au shall De approximately equal to Equipment, is nareby amended to inclutle the SECTION 907.28 1 - (GROUP R-1) MANUAL FIRE the amcanl of exhaust air Seitl system shall be following: Listing iformaton regertling devices, control ALARM SYSTEMS Section 907 2.8 1 (Group R-1), SECTION 412- FLOOR AND TRENCH DRAINS. Section tlesigned and installetl in accordance to the panels, bettenes, wiring, beck boxes and any Omer Manual fire alarm system, is hereby amendetl as 412. Floor antl Trench Drains, are hereby amentled by Inlernalional Mechanical Cotle, Chapter 6. Location of associatetl egWpmenl shell be incNded for review folows Delete all ezcepllons atldmg the loliowing subsection 412 5, Mechanical fans, hoods, when requited by the Chief and ducts Adtlitionally, where options are available, these snail be Rooms, Fa heating or horwater boiler apphcauons, shall meet the approval of the Fire Department specified Dy tlevice type and specific model number SECTION 907 2.8 2 - (GROUP R-I) AUTOMATIC FIRE the Dollar room shall ba equipped with a Roar drain or ALARMS. Section 907 2 B 2 (Group R-1) Automatic fire other means suitable for disposing d the accumulation SECTION 610 4 8 -INTERIOR FINISH. Adtl section SECTION 907.2 ~ WHERE REQUIRED-NEW alarm system, is hereby amendetl as follows Delete of liquid waste 'incidental to cleaning, recharging and 610 4.8, Inlenor finish. as fdk>ws All ski shops shah BUILDINGS AND STRUCTURES. Section 907.2, Where exception routine mainlenanre nave no less man one hour Iva resistive assemblies for requiretl-new buildings and structures. is hereby walls, reihngs antl floors Interior finish OI the room amendetl as lollows: Every hotel, motel, apartment SECTION 907 2 B 3 - (GROUP R-11 SMOKE ALARMS. SECTION 606.2- LOCATION OF SHUTOFF yALVES. shall be Class A, as testetl in accordance to ASTM E builtling, condominium hulltling and commercial Section 907.2.8.3(Group R-1) smoke alarms, is hereby Section 606.2, Location of shut oft valves. Item 1, is B4. All work tables where me use of open Name or heat builtling wim attached resitlential occupancies having amentletl as follows Delete entire section and replace hereby amendetl as follows On the fixture supply to producing tlevices is pBrmitietl, shall be of n 3 or more Blaies, or with rtiOre than 1 t units, classified with Tne following'. Smoke alarms shall be installed antl each plumbing lixlure other man bathtubs. showers combustible ponsbuclion on the surface and nett under the Inlernalional Building Cotle, 2003 atlilion as be lull y atldressable, analog systems They shall be antl coneaaletl waN mounletl leucet5 b me and Iwo exposed surfaces adjacent to such production Group A-1, A~2, A-2.I, A 3, A 4, B-2, R-t, R-2. R-3 antl monitored at a listed monitoring lacdity family residential occupancies. antl other than in processes. S 2 sheN have a lira alarm system Installed i indivitlual gueslrooms Thal are provitled with unit eccortlance with International Building Cotle SECTION 907.2.9 - GROUP R-2 Section 907 29, shutoff valves in hotels, motels. boarding houses antl SECTION 610 5 - TEMPORARY SKI REPAIR Stantlards 2003 edllion, and in accordance wth Group R-2, is hereby amended as follows Item 3 The similar occupancies FACILITIES. Add section 6105. Temporary ski repair NFPA 72, 2002 etlition builmng contains m e than 1t dwelling units or fac4ities, as Igllgws. Temporary ski repair facAities may sleeping units Delete all exceptions SECTION 904 I ROOF E%TENSION Section 90a 1 ho alloweo under the fdlowmg conditions: Explanatory malenat. While the activation of a single Rcaf extension, is nareby amendetl as follows. All open TemDaary ski repair facilities Are tlelinetl as those fbw switch will annunciate sprinkler flay, II should be SECTION 907 4.3 - (MANUAL FIRE ALARM BO%ES) vent pleas that extend through a cool shall De tleaignaled antl intended for !ps man 30 days use, ndetl a tlry valve is allowatl by cotle to prdect an area COLOR. Secflon 907 4.3, (manual fire alarm boxes), terminated et least 12 Inches shove the rod, except and outlined in section 610.4.1. in the range of lorry: five thousand feet up b Ilmitations Color, is hereby amendetl as follows Delete section in met where ¦ cool ie to be usetl for any purpose ether Veniil9lan requirements fp me immediate ski repair imposed by system areas Tnis is not considered its solitary end replace wiM me following: Manual I've than weather protection, !Ire vent Snell be run a least 7 area may be warvatl, pra/itletl the roam a space in adequate in Terms of identifying Immediate location. In alarm boxes should be of contrasting cola Ia Me Teel (2134mm) above the tool welch the ski repair operation is located is provided respect to rife-safety. particularly for firefighters backgrountl on which they are mountetl. with mechanical and/or natural ventilation sufficient to respontling in these areas, it is in the best interest that SECTION 904.2 -FROST CLOSURE. Section 904.2, provitle a minimum of siz air changes per hour, or these areas De further profsctetl with the Installation of SECTION 907 12 DUCT SMOKE DETECTORS. Frost closure, is hereDy amended as follows. Every meals the International Building Cotle requirements for hest or smoke detection devices Section 907 12, Duct smoke defectors is hereby vent extension miough a roof o wall shall be a builtlmg usage amendetl as follows D¢leta all exceptions nimum d 3 inches (76mm) in diameter Any increase Flammable liquid usage snail he limitetl ro roans AtltlitionaNy, these devices shall be itlenlifled with n size of the vent shall Da matle inside the structure a equippetl with automatic fire sprinkler systems specific atltlresses such that firelighters may locate SECTION 907 t5 MONITORING. Section 907 15, imum d 1 loot (305mm) below me root or inside Tne Maximum quantity shall not exceed one U 5. gallon. more rBatlily Ih¢ aolivafetl device Monitonng is hereby amentled as follows. D¢Ieie all wall Temporary ski repair operations shall not adversely exceptions. aN¢cl the nealih a life-safety d lee occupants of lee 1 Double action manual hre alarm pull Slali0r15 shall 161 ~8 AMENDMENTS TO THE INTERNATIONAL FUEL Duiltling. be installed at each level of each egress, behind the 10-1-fi AMENDMENTS TO THE INTERNATIONAL GAS CODE. Temporary ski repair operations shall not be allowed to bar In tlnnbng establisnmenls, at the front desk of a MECHANICAL CODE The IoNOwing amendments are hereby made b the • cause false alarms. It shall be the responsibillry of both hotel antl at locations required by the Chief. the following amendments are hereby made to the International Fuel Gas Cotle 2063 edition Tne building owner/manager and the operator of the ski 2. Interior common corndors shall De equipped with International Mecharcal Cotle, 2003 etlition. The DeiIC ClaealBeds 970.845.9937 / vaildailv.com Tuesday. Februarv.8. 2005 - Pe4e B27 • ~ SECTION 101.1 TITI E Sn t n 101 1, i II f My smoke and c1 all-.n I ol, self .I 'ng a snmhl ns Cndn. shall h2 encased 'n rnnnl is racnwdys, nr an CPCTnn 2. TI e. hu Id nq cMSNS dA<,p1etl Dy Ihrs onttetl a i II- TI t -.g 1' t .1 Il . k ,wn hav ng a Ire-protect pn rat'rg nl not IessS Ihnn 20 apprpved armor. qll w r ng n G(nllp R nGrl panr''as ortl n' n 'I all he .II . 1 a Inc dll Du If1f g permit as Ir0 F of J Gds Cnr 1-~. f It E Tnwn ul Vail her - tiler m notes All spaces epnla'n nq teal Bred ego pmenl shall be Encased n metal cnndu'IS raceways, nr 2n Hppl ' I s - eive 1 t y 11 ~ Town ni V rl pepartmenl rnferrP. cl In a.s "HIIS cnr l~ located in under-Ilrbr (orewlspace) and above calling approved mP,tal arrrutmd cehlq tee the nircnii breaker nt (;pmmunny Devebpmr;nt. F3u~.lrlinq Saieiy and (attic.) aroas shall be separated Irom the rest of NE box Ipr narh unn. Nn aluminum wire nr copper fled Insprrnon $eIV11:eS, nn or alter January f 7005 SEC710N 101.7- SCOPE Section 1012, SrnpE, is building by not less than 1-hour Ilre~resisnve aluminum wrre smaller than size B will be pr;r milled hemhy Amended as lollnws Exneptinrl 1 8 2 is cloleied onstrilcnnn nn the space srde of In0 treating wrthrn the Town. Surhnn 3 H ,any pall, section. su6sRrlinn, sentence, in their enarEly. oglripmenl mgardless of Btu input. Opening protection r,lause or phrase pt Ibis ordinance is for any reason .sliAll he obtained by usE of a tight titling, smoke dntl a. Persons eng Rged in Ion inslAllHtlnn of n mole bald to Ue'. invalid. such derision shall nnl eHecl the `;f CTt)N IOf - F CE SCHEI)ILF SC t'on tllLi 5 7 draft-enniml sets clos np assembl os hav ng a ire- control low energy power antl s goal r. rru I5 8s vat n ry of Iha ran a any pull ohs of [h s oM nBncE antl F : 1 I ~ 1 t y '1'.d Inflows the pmmcl on cal ng of nnl less Ihnn 2(1 m n.lfes All r ,der del ned n art CIE 720 and 760 M Ih rUd, ,Feel 1 ho II e. li,wn Cr nc I h . t y naclares t wJ01d helve 1~ r i nn I, .I r.rl le. for the I ]wn r f Val shall he Ilnor and above ce I ng spares shall also he delecled Icensetl Iltemselves pursuant in 1 II 12. A I I 74 I , 'ec1 Ih s nN n U Par.n part. sPC!lon I I : anti i n'h nr 11 a nff'ca t f the Cnmmun ly and prolECled n aCinfdanOE to VA I F re Deparln Ert Colnratln RAV'SP.d Statutes nn h d tl DsBrl on, 5enlEnce rTause nr phrase IhelEnl, Dnvolnpmeni Department All work regplAied Dy IhE slandartl5 All mer.haninal rooms Shall be prnv den w Ih Suparv5 on M such Icenu'tl cleric r. ens', however. all regardlESS of Iha. tact tool any one nr mn a parts, Fuel Gas Cune shall ha subject in fees as de&ignaled a Ilpor drain a6 regwreU by the Plumbing Code of the such persons shall ragrsmr wish do Stale ElPCincAl sxbm,S, srh5pnirnn5, senlances, clauses or phrases n the cnnslructlon lee schedule Irn mechanical Tnwn of VBII Boartl Proof of rogistrefion shall DA prnducEd by [hE hn cleclan:d invalid porn ins rP.gislranl end an appbcalion for conlmnlnr registration SECTION AOA 14.1 LIMITATICINS SHl'.ti(Nl 404141. Shall be prpvided 1n the Tnwn hf Vail Flre Marshal inr SECliori 4. lhP Tnwn Council hereby rinds, tlelermines SECTION 106 5 3 FFE BEHINDS. $flCilnn 106.h 3. Limitations, is hemby amentleo es follows Plaslie pipe re ew in ecchrdanre wish the Town Conn. sertlon 4-2 and dnclaros Thal Iles ordinAnce I5 necessary and Hrn lelunhs, Item 1 Anil 7 rs hereby a ended a shell be installed outside untlergrpund Only with a 7 vi prnpP.r Inr Iho health, safely anti wellarE of the Town of 4,Ilowti Item P Nnl n n Ihnn d0°G M flrnrrpermn rue minirnrrn, cIPINh holrrvr innshed glade. M 1P mrhras Vail ann ion inhabilanls' IhOrenl paid wh,•n li„ work has h~!<iri don. under a pr~rnirl Plaali~. pipe shall not Ud r Secl williin nr uritlOr any C All such installalpps of re ,nIP. rnnHnl low energy InU ni Ar r.~rtndnrri whit Iles rode Vern .3 Nnl morn bull Uiny rn slab or be operaietl al p(a.$SnmB gmater powor dntl signal systems are subject to Iho parents Sc0lion Th.•. a IendmP.nl nl any Flrovisron o1 ine tl4rn tl;l°t.,d the. plan rnv,r:w leo paid whm, an Appbcant than inn psig (6n9 keel) for natural gas ur 30 pslg (707 and inspections snl lorlh in t7-73-t t t (24) CRS Tnwn Cncia as provided in this ordinange shall not Inr a prrmR for which plan roviaw Irds been pAitl is keel) far LP-gas. Accordingly, All insta118iions nl remolF. control, low allEC:l airy rlglil which has arc ued, any tluty imposed. withdrawn n canrolotl before Any plan rpviow lie- energy powor and signal System;: must he pork rtinecl any vudannn Thal orcuned prior ID Ilia eflechve dale been nxpenrlnd SECTION 40ti41 ZEST PRFSSLIRE Snrtion 4()6A 1 maccordanrA w4li Ilrn rtrinirnum .lnnnyrns sal inr Rt in hnrunl arty prnsrnuhon r eneacl. our any nlner Tes( pn'ssure, is hereby amennnn a< lollnws. 71ns IECI Iho Naapnal fl0i Iris. Code :ICiinn Or prnraadincl as cnmm need under nr by virtue SFCII(1N .11137- PROHIBITED LGCAIIONS Snclinn shell incluclo a carbon tlwxlde n nitrogen <~t Ate provision a ended ThA ar andmoni nl Any IT.i' . Pri ~l I 1 1 I I n 1 -t y Art ended as pmssun lost Pf 1'nY ( p the gas piping shall 10 1-10' COPIES OF CODES AVAILABLE prhv.' n -t y sl all nut rev ve eny prov's on or any It ,l~b rt. r { I n, y ld { n Ir car not roly And W II stand a prr; s. u e I not IC55 than 10 ps g (60 kPa). Cop es of all the. codas Adnpied by Ibis Chaplor and all ,rt1 n' I usly «'pealed nr supersodP,tl unless n rulnhr:r i~xi'nption S ninnhnr 7 For weldaU pipe and Inr piping carrying gas pressna Andmenis thereto shell he availAble Inr nisperiinn at expressly .staled lurr Pin "oading I4 In. h WAIEr Column, the 1A91 shall he at mE nHicP 01 Ille Town Dlelk SECTION .7U3-4- PROTE CIION FROM PHYSICAL IP.ASI ti0 prig (414 kPa) Section 6 All bylaws, orders. esalulrons and DAMAGE Section 3(1.44. Ptolocllon Irom physical 10 1 11 PENALTIES ordinances, or pads Ihemol inrnnsislenl herewntr are tJ;trnaga, Is herruby arnandod a5 lollnws Appliances SECTION A06 4 2- TEST DURATION Soctlnn 4Uf 4 2. A Any porson who vinlAlps any nl Iho prnvrsiuns of the u~pealod In Itie Extent only nl .ui;h incnnustancy This .I'll nnl D. I'll 1 A locator whir. bj .1 In Tosl h rAlnn h eny amended as loll ~w5 Tf!SI Cntles acfnpteU by Ih.s ChApler n[ 1811 rn conµrly « pnalet (hall nn1 h0 cnnslruvU in YEV Se any bylaw, pt y=nr nl Ua ago ul I,.s prnirr .Ind Uy ; rh SldnlrAl d Irabnn shall nM 1 Irs.s Than 1S mrnulns inr Ihreadad IhnrEwrth, ttt wl t vrnlalns nr (a IS In rnmply w Ih any r rdnr Snlul nn n ofd na r,e, ,Ir (art Illerenl lrarnors approved Dy Iho bottling ollral pipe Far WElded pipe and piping carrying gas order made thereunder, nr who builds m vinldlon of any rhera.InlorE «~pealeU r pressure exneeding IA Inch w81P.r column. the duration detailed ctalnmPnls, spP.c.lirr.afi<Ins, nr plAns snbmiNen SECTION 304 1-GENERAL Section .904 1, General, is shell not he less Than 30 nnnutes and approvod thereunder, n any corhhC.ale or permit INTRODUCED, READ ON FIR51 READING. harndy ann~ndetl as lollnws. Air Inr cnmhuslion, issued Ihereuntler, nr within Inc nmo fixed Iharein Shell APPROVED, AND ORDERED PUBLISHED ONCE IN rnililalinn, dntl dlluiinn nl Ihie Itasas inr gas ulili]Alinn SECTION Sot A EQUIPMENT NOT BEOl11RED 10 BE ba gorily of a misdomeannr antl suhlnrl in penally A5 FULL ON IIHST REAf71NG Ilru 1st day nl Febn cnr y, rquipmenl installed m Inulnings shall hr prnydCd front VENTED Secann 601 P Equiprr eel nnl required In he. provided in Se,:linrr 14 1 of Ifns l:nde lha imposition "'(I(I6, and a potter. heannq Inr >ECnnd reading Ol this II r Ian. r. W If nr v app I I the Du Id ng nt 1 shell h t t y fended aS follows Ocleia nl a pnnAlly fur any v'nlAt'nr : h II I xi use IY a Ord'r I Inr 6'00 pn n Iha 15th day nl Fattmary, II r. al Ile m,:lh rds presr.nh<: 1 . t r.linn 3114 ? play fEm R Rnom h alt.ts 1 6tet) for 1 A trod t Ap and VnIAI nn or perm t i to runt nt e antl all h~persons 7llfl5 II ('Door I CI do hrrs nl 11 e Va I Mun ripal bu use•n in exisiln4_ hnlldings. nnumbnr hams 9, 10 drd 11 as 8. Rnand 1U shall be requimtl In correct or mmady such viulanun or Building. Vail Colorado nelerls wilhinarrasnnahle lllnn Grin eanti day thAl the SE C;I IQN 704 6 IND( N7R COMBUSTION AtR Snrtion SEC710N Crl r7 (IFCiC) f.OG ! IGHiERS SRrlrnn (i(17 i, prnhihilnd cnnUilnns are rtian n.f~nrd shall cr~nslifuie a .IUA h, Indoor rhmbuslnn ai is hereby amandnU as General, shall hnreliy hn emended as follows Log sepuralo offense lollt,~ws Dubin Ibis suction in its entirely lighters shall ha. prnlahnetl In he in-slalleU in the T wn - - of VAII B. ThA Town may n ainidin e ai:lion fur damages, SECIIQN 3n6 f OONSTRlIC1lON AND declaratory relict, spenific. perlormanca, miunclon, n Rrrtlnny E Sllnr Mayor {'HUTLCI IQN Snrtion 7115 6, Consl nrCllOn and SECTION 671 (IFGCI UNVENTED ROOM HEATERS Any other apprr,pnata rebel m InE Dislncl Cnu» yr and pnilnClinn, is huruny amended as lollnws In all Section f71 UnvP.nled rn<xn heature, shall hereby he for Iho County of Eagle fa any vrelalinn of any nl the Ai TEST. cupanr:ies plher Ihan fl~3, bettor moms ann fumacE dmentled as lullows DEIPIe Ibis section in its entirety. Vmvisions nl this Cliapler (1097 CndE Ord. 75(1591) shall ba prnicclEd required by the 6 Inlomahonal Bolding Cnne. In R-3 n cupancles. 10 1 9 AMENDMENTS TO fHE NATIONAL onlainlnq A bnJnr tpnlrAl heaingrpla nl or Ifni EI ECTRICAL CODE 6) Toe builtling codes anhpled in Ibis nNinani.E shall Lorelei Drnraldsnn Town Cksk water supply Dniler in s nl 400,000 Birl Mr Dnur The follnwrng A entlmunls a e hereby made [n Ilse he eltnrlive inr all buJdrng pnrnlil dpplratipns input shall De supaleledxlroni Iho rest cl the building by National Eleeiriral Cntle;. 2002 ndaipn reserved by the Tnwn of Vail, Cnrnniunity Davulopmonl not loss than 1-hour Inc resistive cnnslruction on Ilse Deparlmonl, Building SA(eiy R Inspection Services. >itte. of the heating oquipmenl. Opening A. All elr•.cirical wiring in Groups A, 8, E, F H. I. M antl abet January 1, 20D.S prnler.Ann shall be nhldined by use nl a IigM biting S oncupancies as tlehned in the International Building Published In Ifltl Vall Daily Frhnlary R, ?Orr; TOWN OF MINTURN, COLORADO ORDINANCE NO.1 - SERIES tW° ' AN ORDINANCE AMENDING THE E%ISTING SERVICE CONTRgCT WITH EAGLE RIVER WA- • TER AND SANITATION FOR TOWN WIDE WA- TER AND TRASH BLLING SERVICE AND AU- THORIZING THE MAYOR TO SIGN THE CON TRACT iHE tOWN OF MINTURN. COLORADO. OR~ GAINS THIS ORDINANCE, READ BY TITLE. ENACTEp AND ORDERED PUBLISHED BY TI- TLE ONLY ON SECOND READING THIS 1ND DAY OF FEBRUARY y105 MAYOR • ATEST JAY BRUNVAND. TOWN CLERK Jay Bru ana, CMC ~ OlerkRreasuror T n of M'tnlurn OBica. 9]OIB2]~A645 Fea user BZmnuan 6 r i9 i orp Publisnetl in the Vail belly Tuesaey February B. 2005 a , a ' HAS BEEN DONATED ° a e e ° ~ a' to charities by ° ' ° ~ Colorado Mountain News Media from your advertisements placed in . I ~ The sw~?p Ask for the new p ~ ~ ~4 r C h a rity~ Yellow Background aspentimes.com postindependent.com when placing your classified ad! s u m m l td a i fy. e o m• va i l d a i fy. c o m • 845.9937 Keep placing those Swap ads... we'll keep donating! - a 'c y } ~ w ~ ~ ; ~ ~ ~ O ~ d a~i A G ~ ~x N A yN . ~ ~ O O `a vj ~ e~ yq m O• O A H , r yC1+ y end ~ e? 4 Gi v' cad ~ ~ ~ ~ t'~. 'z, o ~ ~ o. H T~ ~ y 3 v \ ~ ~w Go ,a C/1 ~ ;j N "O 'd ~ O , v N ~ v~~ w N v ~ N~_ U 0 ~ > ~ c ~ HOC 3 ~ ~ ° a ~ ~ ~ a ~ ~ ~ ~ ~ ~ at ~t~ y,+ N y u ''a"' Cd ~ p ' V ~ y~~~ a ~ y g O A G ~ cU4 ~ c'a A N a~ ~ 3 N OG Q, G v`3i e a ' ~ g Q,,H U ~ ~ ~ ~ U A s _ ~ , ~ ' ~ c+i ,p ~ ~ ~ ~ _ o w~ m ~n o r iri d ~ U ~ m a pi a ~r E Y c>v z c° ~ m ro r- cn m m m va Uj ; ~ m . ~ ~ ri ~ ~ cp .c ~ m tL ~ 3 s w ~ ~ m o `o O ~ o ~ t .n ' L f•- .c - ~ COL ~ C.m r 4~~rCaa E..-._ ~ ~ U m m ~ t- ~ m' ° . m~.- W ~ o~U a LL ~ ~m U..: o ~ cv, mc~ym~y. _i~~o.ai~ W~.°'~i~~'6 r>~'° 2~ ~ m n ~ O m ro ~ y°- ro t d n m c > n n c as ~ Q. Fc w a a~ ~ro O _ :-roro~U ~•E~ zm°crop~ wn~oo 3 ~o w~g>, C"#~^ H m n ti.; m ~ m C n "a. V) L i 40 Q;C1] y , m ~ ~ ~ p O O y.., x . .--ff•,'i3'~" ~ a'~ fA~ ~ m., - tiro ~ ~ c > C~ m ~ m L ~ LJl ~ (R, m O C G3 C d m C_ C ~ O F-b?~~L ~ E•Cf yO E it .II U~ _ CQ~ O- cn n a~" mac, w`~°o ~ ~ mc~~cmv'E~y ~ ww°'E ,n ~m ~ r!•~-u 5 ti: Qom: ~ m ,'~`'~...~mc~•~ aU~aa~`m~ m}.m Um~- ~ o LLZ ro wL z0~~ ~~n ~i'E~ ~ ~ cn a. ~ m Q ~ ~ o w v m a. u. a2 • o: o ~ mo ar ~ ~L m ~ ov c+~ ~cna U~> `Z~m I• mL `t =m ammo rm ~ o- ~~o>~ op ao~ma, w I.t ~,~o m' a m `~mo_ m ~'w~ ~ me o ~ O ~ I m° ~s ~m - c~+"~~.,cs~v~U`~~. ''•momm~m. ~an,`~~o `orom N4~ 1`' n ~.ly T~Tron~ T y. dZ O1 O L.O <G O.Q ~ @ mm Or O O.wb''C CtO.m ~.s..~-~,~:,~'[:""`. ~ ~S1Tjca n~ aC:: ~ra ,-L::;r.-~M••~.rom• o""'.ONp Z LL U. m~.~ -m•C... o Z ~ ¢ ~ m- F'-'; ~ ~ w U o z,-. n = m n c d u. f.. c c ° c ~ L a OQ fl.~.~ a °`f` ~ ° Z o @ , ~3 ~ q•Q-~ O m m ~.x. Z o a•~ o Z _n.. mm ~c u~ wc~aa y om cN~.~ ~ mn O~m-ter _cc amm m°~ F->m ro ~mm w..~m ~•o ova~'_° ~ ~~m= m~ m aaoi d m Tim Uw>mm Uc~°-a.cEia-a UUtQ~'c0 Uc~`-cm.~ °~m mamas Un=~ C wa~Q.C ='*m oZ.c~ WcL-mi._-~o w®m~mOtrC' W mOmL co::..til~~.-~. L mm 0 wn~° ro uam~ ro mww U m ~ ,--1-... cnaarto mC7D ;=-a m ro cncn ron ~Zs" ~m.-~ 4~c%~ c~ ~ o a.n v cnd m 3 v ,En c mam'• o_~ ~ mm; Qc ='isoia~ off; o~'' Z~u1L~q o~ m mE. o•~ m LoY 3~ m° o ro _c3,... CZ a ~ ° m c7 ~ n ~ m ` ~ ~ ~ m v g E o ~ m m• ~ . ~ a c> IZ_•- m c. m O ro- ~g ~ ~m ~ 9 C ro m ~ d € , . ~'a O ~•j V ro.w ,..'C C - (__1 0'~.` Ca l^ J; ~ .L+.. ~ O ~ a to d ~ m 0.t ~ ~ - ~ N. ~ ~v'' ~ f.~ . ; O ~ ~q ~ 'LY ~ of OO tL, W4-~y GeV ~ ~ m cv,~' U°U~ c ~m3 w W'N m~QQ~~ CC ro~.: wv mB1 C L ~ p .rro+'C X ~ (0 i0 - E ~ 2;: ~ m . ~ ~L m 4. 6 n ~'3 ~ ~ a~ w N N ~ U ~ ~ O C o_r o q m._ ~ m d~E c: m~ mo-w m ~ , ~ ~.5 .-n ~er. ~ ~ o Q m~ a mQ v;c ~Q~ ~U V.1°EuoiLm ~ ~~:Q, m~- c°~~~~w- Imo a T m $ ~ ° L r ~ u. ~ O ' u, is uJ .o ~ ~ m v E „>a O O C) L w . E i~ - 3 a` f- v, w m n w vi ~ :a: e m ~`a m ,n°~a:; °c Eon m w~om cn me catoro•mo~° F'~, n_~~ .wm~•~ ~°T~mo' m~~,. a~~ E as ~~~`°,v _cro_c t- _ du>,o-m ro L.~m o°~mEm -a °n vi ~ mY a~~, roc•- ZL~1E°-~' ~o+-~, m_ TS=~ `yu mm o~ ar~ta O v! N E - 3 ~ _O ° m w Q C ro I 'O ~ U. w E m O C ~ U~ ~ ~ ~ W. U ~ Cj ~ C . =m v ~m mn m m E va. m v S. tt= v ~Q°~ m~ Zo ~ Nc~£w urm Nro~~; ro c ..~'=~"m'. o~-a ro emu' X13 ~al~om ~UE- $ a m z c.-.~~ ch 3 ~ ~ C O ~ ~ C - m om orocc`muo y~ Q ~4~00• °®~o~•°va m~ m~m~'' v;~~~ IOvaCNroL°Z, ~Lt47~ I'.17 ~.-C C?~ C a ul d ro ¢rom m mw 0?+ Lro ~OOCtl~O i+0~ ro o u ga >.ro• ~ Z~ c z u° Z'^ m u} Q Z m c~h- Z n aE ~ ~ L ~ ar ~ w ~ r m w o. m ~ us ~oa ~y ~`m~ ~ ~gm O_ cc- ~ _ O_cm T~ Q 4 R 4 '7 a O m ro. C [2 W 7 -a ~ C n ~ g m va ? ~ Gi ~ O ~ m « 7 ~ C I-" N A L m I"' ~ ~ ~f1 ca 0 F,. cn m ~ ro E... a c ~,~E ~~Ec~ ocn~~.Y>.«•~ ~mm~ ,-'v~cm- Uom,a.2°~ Um ~yc UZ~m~° U~m ..o'c cmc~' > caw. m w•-mmm $ m m > ~ c°y?~, .~t~pU E ~C7rsC?d m,Q~ ~ w`~' ~t~~~. cn~.ccc~ c~. r~'~~"" _~~~5, ~ ~ b' ca~ ci~UO c°~Om' ~ uwic~ i " f6 m of ~ a o ; A N C J. T C 'p n a; - ~ L , i-= ~ m F_- = ~.a ~~~~.`!-c.~vE mmm~~` ~ ®~ro Z m~ wmavm ! O o fur ~~c n o"mva cmc• on-° a fj no U`mmc~y~ m ~ ~n'~ o m mo prm ~.~~U~U. m-cLy wrwn mho@. row. OLwEm 0 u-.. ~ ~ w~'a;~E w4- a Cl. C~ n ua _O y ~ 7 - ~ a.U O ~ I- E'O -U W ~ m C Q,. ~ SY ~C T 0:.` . C E LL ° C,~ •~j O m m ~ Ll_ m t0 C a•°' ° ~ ~ ¢ m m ~ O n I-- ~ •a y ro U O - W .R U ~C 3.- R C O v! ~ N (aC <f1. ro ~ a (h Q ~ U ro. ~ n' m (ri t7 ~ LL E O O C ma"'"~ oc'ro'-o~ c ~~E w wNo m?± pr ~xm;~ca3o Om~~U C7 >.`m~?-' us°os m°~ in-° c c 3 F, m~ U m °'a~ ~ w LLI,,~,1~ 4 0,- ai °'c- Z'~. 4 y N ~ n U 2 U I.L = N n c a: ~G m • w w ~~E •nti ro F-- c~= o mam ~ Zo w~oNm~:°m _woom«-. Dm (s ~ E ~ (3 C ~ ~ ~ = m_A.~ 7` m ~ ~i"• " m N' w C.7 r ro C t~ O ~C y' ' O .G. U L J mroL - m m ° UCO Cnn? mw ro ~ ro'~" ~ U: ca m ` n M m.c c-° m m~ c= c~ m m oU mL- ~.m', O~ ~U o~ Q ~ a#i~ A t ~ pUpm C ~ v1 p'U mn ° O L U L ro C m v L t/i- Z. m,v O'i1f "F3 Z F-> m 4 m 0 t1j LL m N m O H~ F- t? CC a) W U L va O N L U c y~ L m L N' C7~ O ro m ~ (n m C ~ C F-'." ~l1 'a'8! W~ C. U. U p~ m r m ~ y ~ ~ ~ @ ~ F- ~ N ro 7 ~ C F- ~ m O m. ui ~ u] ` m. N (!3 fh N' ° ~ ( C r~ p~,, Q7 n r 'a m, O tl U 3 c ' IL- g ti'7>-` ~ ro •C3 m U C O ~ ~ O Z - I w i%! O -sL" I 1ti r C O U cV 3 O c c m U o~ go m ~,+'r~;t~i.o~ , o-~~U ~n m•~ °-U g acipop- 3L ~ a of I ° o~'~:.c~ ~ m w m n oio ~vm 'oc~', w vmo w cvc E1cC~jmcc• c~~3F"'.. ° -c~ ai - U o m •o d E - as o ~ m oo m ~`n~ m•~'=v roLL mn c U~•...U ~ ro mL TcN-.. z0 ro ro o oLn r c ~n;,,$. E ro'$ mr .c ? o~ ~c~v`O E pLOO cEcmm° c3° ~'t7 o wOrna o~v,occ°i oat. om,~racmo~. °.acv'p....E~ r- ' O C - m c9 O U C O O C C ~ c O ro ~ ~ t6 Z ooi~o~ ,o~°mco o>•ro~m-`° ~~~-~°~dC'3'3c Z''n c Zrn'~j`f'flm..~ Zmn~'~~. ZO 6 n = .~roro~U cZ~°Zmo dN° as ZoL m m~ Z._ 4s>,aTm. m C,? m c a: m O c -Q t O O E O cn a O i7 m c ~ C7 ~ w m .r m L E w m ~-'3 ei p 3 ~ t= o c v a t=. H- ~ ~ ° " o. E_ cn - F., En c''> n m--~ NaN"'m °'~-o`~ 3 ~c tnmmcm 2 - oOm~~~, aa~mmo o°o>,o. o~~ n~~ °'m wa°iEo~c~' w° ww~c~ ~~'ma- wwEc=,~m' wQ o`.U~ U w eLUO. ~m wU mUnu: ~U ~ qdQ tncq car m a cn m, v~pt o ro_ m cnu. ro ~ Ed rn> tD - N' ZZm20Od¢QC}7SMawwIU-Z E.n e c ~•°a~jtU-~°~-, `o mYY.oLm. m ~ ~ o m~'=. ar ==i d- F- ZZC7mF--emUZ o.an. aou.oq„"Uo ~n`o. c E ro e ~d p~ryLLOO00wwu.~~pw~ c m roc ~ ~ ~U~•-w m o y m ani m ~ o. t ° o o.va~-~ ui . 2 F.-~wZO 2 fi._ E c c ro mU"I~ = o E~ o m SF=p dd~w OUZUd on o onC7 m- m E m o.~ c~ ~ mti m m Z Z cn w I-` m ~ •Y v, ~ v, m Z m C7mam Zzw OdwaZ I~nm me°LLOCC °'omE3 -a> .a~•~>o->«.~ DO o4 ~ ~ Oct~Ct ~ a1 3 ¢ c` coU~U o ro o ~ o c m c m c m m c.p wZ U~ ~ S~C3~F~~"~--`d ram m mc~irnm .U~NUOaU :.=-g ;..~rov~me Z e ~ dod~zF~ZOwnw4>Zd~ m~ a = m c m ~ o oZ m m ma c Urn G v, v m Qa aim r.._ Z_ O- u~ L~ o.c ~~Um r~ roow3 c'~~ c~a~~o~' Wit- nm e~,t?4u~ iti F-d. OmdZ ~ m-E m ii.cUroo omr omt-c ~ro f7ltl~pp dZOUdI"'Q v~ c ~ o w "a--LF 6,C - o m o£'> m a Ow ~ ro ' Sm0 2- ZO ml-(7 0 0 - arom o cmro - U~ro UL c`-a• mm wUc~ppwOlwm~c~-~ wQZ m m ~ O c`o d ro> cpnj c,~~ c m~ E m m ro HF o. UDwduiQ Uw c° -aO - o o~._ c 3 ° ~L,~ m c ti v, wQZg. ft'aOZZOV= U~ wmU~~-mUom coiorom oYc o--aL.cRyrom wLL ~ ~ C7 c•C o m c ~ f- c H Ca ro~ t m o U23 U- Oar- cnp roUw cv _~-o>,•r.n ~caa -m3 -°m~Eo~°~ O.. . ZU.~ZJJ.J twjl""ZW FI-aW S~.roC~ O m~ C'LL ~W m 7 p ~ U ~ cC ~F~ R1 E~_ W. ~ c0 ~L ~JQ ~ US d I.-ddd Z ~06-mZm ° - ti7n m m ro c > mF-- m o » m > ° m'a ~ `mLm•, OU= 3 Q Z~ryJ ZZZQ~ . ~w1-00dw o--ma>~m, °C2~ ~ owor .Lm..Y~ ~•m ~ m~ Y a3 ~ e ua ~ZI'" ~.va o O . pzdwOOp 1- OIt 2 U -a E.•- rya ro c.`~•rCi o 2 t C-3 r:U m ~ > U I•- t= ~ U j _i d t- ui C1 o ui m m ca ~ cQi ~j uj a o a ~ vy m vo, uj c ~ .5 cn • ~ O p C? m pU WdddZ~ rrdQ C7dm d oc ~ alcU--L' as Q.mcZ `r m c m ~ ani E mn ~ n m wZ ZZZd- wzppuiZ m w w- o v, ~ w y $ cmi ~ ~ t2-U~ - ~ o ro Z ZwOwwwwwj~OOwOw2w a°i o~ m mn~ = ao~ ~ Y o.m = mn °~t ~ E ~ 3 ro ~~O ¢¢UmzzZ~a:UUZrrUcnr-m. 3m ~ ~mmUo~S mU mS ~ ~ ao ~ m mY o m m o z~~ inH°- o ' {J~iw j _ _ °-'yo°'~~ OQ~'amocm`oo~~f`oro-°c~Nmoroa~m'~m° .~?o~~roro ~jmoLU N~;ya ~o~y~ L L ~ w 0 3 ~rNY~n~ ?~roE~roroc~o~a~~'a°~ `Lc~v,~°m ao~'~~-p cno.'o r No3mo~'m ~ Q o O m m`om' m cm ~ro° c ro~ ro.-' m dam m m°c am mU m; m i-L ~t °a u, ro 3 aco L ~ a a~._ ~ m TL N o c- w~. ®~c ~?m•co?~vm•Eair~oo~°'U°roma,~~~~E ~~~m~~ cn$-o`o-o •~m`-°~cc°ia`~iaciE u' Q c"3ip am-otmam'` me m a>~ ro Ym a O ayi~ w~c~TO~~~an~~mmocE~~oa~L~ `°°~~~'m Z~ma.~N-iric°~cac~Em ~ S Cn C C 3 X Q5 m -O C O. w I ~ U mia gt,ar L ci- m ~._a a~ ~ c E r o-oL ma ro ? f!` y~ WQ~? m: 5, o~n<'~~y~m •a-ot ~goEca ~-~'~n'~a~ ga~O~. m~ O wZ coca: t o_,-roy,,,c•- $°m;g E ~-~o O c c w ~ QQ N•~ a~ ro N v ° ° ~'c m v ~ ~ m m o ma in i0 E- ~ ~ I-- o a~ N m o o ~ U _ o-oE m ~ a~o_o L rQ~m romp. -40 y v~ ro E ~nam ~•C~ N o ~Zr m ami•~ ti o o~ N C ro~ 0-ro ~j3 5'L O.~ j c N~=~ o oU:~ N~ w N c~ E c~:~;~-, ~ o~~` wccam-~' U:a~.~,o`om° m .ogmam m.-~~' NO) ~~moEL ~Ta~~ro a~ LL =i ro mCti'~• ~ gOm > O.m tnNOO U~- ~XL bLC ~ c~Y~• _O R7C _U J•n 9m.uaccV:: c~~UE~o~am`~>,m°ayi-n~~Lmmumi~~ocE°c ~~.T~rot~ ~~~ofl-.~ WmamroUmm a~m?~t. m ~~cmn•~-ta°>~m._c~N._~oL m cco~~o~ r-Qoroco w~ro~mxmE u. -o o mr wa QU o c cam m o To a m'o'o..- c m ~ ° ro ~ m- m~ m I N'N °mm TU ~ am Urom.~'OEjOL C~.-mm ro~...~ mLaCO U~ rZroa,~~ N- ro ~ 0 O. ~ . Y'.L ro m rQQ- mYL C ~L Ti.L--- U ro Y 0.f m~ C~ U L ~ of O ~.O O m,~ TTm N y oa c~ U~ ~ ro c ~ ro w'o~°c'~ wv,~=•~ a o•o c Z~ °roC o ~ N ~ ~.3.~ U.q? 3mo Z- c m cc-m._~~ m-o > Z- cm Z 7 m.N m O OSIL diL ~ m ro~ > to C 0.. = O C£ m m N'D N'n V N = roa OQ.m ~y 0 mw O of m y ~ U roY`om.°~c F=~-Qa"ic°y'o ~.-accroo:8:ra >ro°v; cmcm°o~ O mo~Ea~ci~ i 3 o UN- m ~ a~ c'~ m m- ~ G C OL C m v,?'_~ U ui m o o m.-.` ~ o Y ~ or5am~a w~¢°'LEca-°c aa~~~~s~~~°?t~amimrm Lcoc°CL~m w>N~>°' wm~~roE~"mX w , 3..m._a~o cnw2o~cnrom>>~naU....3~n~roarocn ~~..a ~UE._..roL cnw°omo cnw?w....m~>m cn ~o~ Zm~~°c~cY~m~c~om~°-~tm~wt•«`-?m o~ Zr~'acc~: Z~ `gtE~L~ p?o~~y E-m wiu c~->,cc•-v~.~w,~4=o•oE~ cnygE oa ¢°-ci~°°'°~ OE-mN~ ©~n c .c"3 ~m cmi•-`L~r~oa,m-°°o~~ca•~°acY>.Sm'roz mm wc~mo~~~m U=o~~ocL"~~.o0 3wv`°~°' I -.°0~'0>00o.°°'ca~~~'Q~O~EvEn. '~-o wm•~~u,m wur ~~`E.~rocN ca mw d .°~>,~~•'~..:m~ro'm~~soma°i~cnc~a~~ U ~Qmro~ ~'-~i°'~m~o~oa mpS".aGi~o ! mw woi3Da•a'°~m~ _co mom~o~~~N~m pmT w_o N~mro mo,G, ~~ra r u..+x-~ca 30° ro g~nE or,c > aca ~ a~ m > o.:.~~.. ~~rooc~ .o i N C7O O ° c a>,o;,-, o L g'G~ w T.. ~ ~ 3 ro m o o c..~.- cnty I ~ m O N O m O .O U w C in y m n).". E ro..= y 2 D } U V W-..O L O_ F-- m C RJ C'3 CM m ~ ~ Zm ~ c ~L ~ m ma ° o roa v m mL aGir ~ a~ U o> C7 m N Zm ~ ~ m ~ b.m ° ~ E EL=~ Z~ E~U mLm,~m =omc3n-o~m•~ron°-ro>..EyO°~rno>a°ia~ ~mc ~ a°ro~'m ~wo•~'oa~no~s~~ OaCLLL~ u 0 0'~~ °'-oo roc~o.. irico-nE i orm aa' o O m ° m ~ o-,c~ ~ ¢ ~E"'.~ amn w c w ro.._moT La~E~oY u'°~no~,~ m~ m i m o~p m ro o-o~.- m o g o~ o a p roa ~ Ucv o gZ Ana o ~ rLL O~" ~ o~ o c ~ o c•`A maa~ q~~`~ELOmmLm-oc0m -oLmamv°'IIm-° i ca w_o_macio~m d:,-~~Lwyo~.r m~;- 0 1 -`a°m~ cp~ao~g°oE~Lm'ro~•~c~cco.mro~m~~.wms~ oaX ~~~a`E°~~ o~~~~°EYm~,.~ `'ocn~o`° 7 T C Q.Q y C. 0 0 0 L y L~ a~ cd L V C `p O m C'7 m m M O C m m m d' CO T C .ro O' c Z a °w~, mrov,~~ov,o o•-ma.-roo-o=OOmc m°w m moy oC0 -°~°~v oCOcm~ i ~.naio Z c•~a.--or'mcE~NQc°aum,~n°-uic~u~oiy wY ~Ea~°i~.m ~~roL~~,E.~¢ ~=-°L ' me °mcao~-cm cm -a Z Zwcro Z a-m oo~ ZQO"a -o m E E w~-m-moo-°E.Y O -m OJp~Taci>roo~ po-mo~ o00 0 ~c gc~o F-Oa~~a`~im~Ea°io'm~-o3=°Ymo.~Q-~aNicro rc cc vi ~ I=-Z c ° _ U 3 o ro ° aN w ~ ~o ro c >'c c Uo ~ Utn m a~ a m m U ~ m-n= °'o- ao U~ oa ~n wO~omxm~'o.°.=~~~°LTG~mt°~=mad wcom wwEm~cati wmEcrommrmm wOoam tn[C m oL m ~ ~ a.,_ ro-:.=,,.u,a o ~a:~Qt ° ~ cnma cnmwL:~: ro o n cnv~ ro m 3~a..acn cnw 3 roa i m ro mL~C ~ T~ m O'.-. O C OSLO C c O O m ? m~ ca m- Eaa O ro~ ca S ATE ~ m- m NQ C O m ELro~c~o•-o a°LCC roYo-- s Z om~~roccc com pc.n>°~roL._m > I ~ -~°o Zmoc~mrom•`~-m~,~o>.-no Qm°a ocro~QNO~m3rom wa~co•~»- ~ ~o o...on>roT E~ ¢ o•-= mm a"- o= cn•-m•-°oo ._m,°._ro w at m°-o~Lmorom -o Oc wmr cn ~NNr m~o:~=a C7"aE v,c^~mL wa ' O in S.WymA ro'~.-- a'-U mr~OU- WCC E vo wCOin Q -O m,J o~ina? ~c croE~ mC7Y-oc'~L~,m Qmo rom~u~ oom~, oo Z ma ~3¢>F-cL~ ! ~ c_~ocwTUo U•-.oro ma mo>>~rLn UO'... TamaocH'-~Eo D _Ecoo1°-va ro , i _ t o__ o 0 oa a `o c m c cn m cii m o ca ~ c° `pa >,ro Jr ro v mE m~-' c cmiY.`0 O N~CNNUf-Q pC~O C-m> m c/)OYm00 wrU ? roCL ~"OC C ~ChT C .L..c3~Cm"' mro~~~~ro~_ Oaacos.noo~ oQo> o `nw ¢Omoy^=°roo n~Qm moa co Eo o G ro to } N L O C T "n r 0 F- 0 m a 'n m C 7 E (0 w G- a ~ U m d.- U m O CO ~ U O J .N C w !n'Q U- p~ O~ M~~ 'j U m cq E i ~mY a_.G> F•-~~ro,~o~ mco L0 ~ Z''~ri N~o.-o;',..roc- C7 m>aS~~'~m°~E>, co a._ o m m° •c w e ui w- - o ° o'c m Z r w L m m I ocEo me4o Qo°-a~,mmm~,:m~'~° C74o ~-o°.~°oa°c~-mL t=G~_n m''>rnam a-= rm c~•U ~nm ~ oc a•-~ rooo a >rn o E~yELEam3•oLL~Z.~mL~ ro~~ ro°7am woo ~o ~,mac~'mmo ~O v~`o3¢aaroro°~ ~ om~Lm,`~oUmf°-°o~`°vi~'~cL`ouia~~o~'~,~~ ~in~,~ ~3°L~m.°~v,=mpm - wa"i~~~Lai~a~uiv,~ I .•oa~c`~~;,ro£Y~w~oc°io~roa~o~~-ino~~o w ro~ ~~~U-o~ciY=o~~ TcaUO3v,oQ~~~ma ~m~vo,r .o.c -°U?-oco°m= -mo u~ -o •c Ewa 'a--.~-o om> m-m ~°?'3a~~(?mom t _°oQao~~°, .~>Lma~cmi N -om °•°•`~o° o°a~ ocii`oo~~~m-ncm Lam.~~•- Eor ° m c ocm m m u-aG C Or C~ > O.n O-"'"O~^'p-mC ~~W OrL.,. mCm m N a O Q O m O m N U cm*"O U 07 N ro mm O`?S C._ OO m rom -nom romp cmm*-r oar o m rom"-c oYc~~ ro Z._o ~ mN cU C7•o~o0~ E E~ ~~r;cNL mm~ ~ o o,-~c S Occ~~~ooEaaZ'.'~°o~-6co mcm morn Zwroc ZC7;;.°~~'~°E`o3a°i Zf-`~ °c°~°oc.E Qo~Qacro,po~~oa~°'~'~a~a°1aa>o~mo O~T'm _ON-°oa`~iam~roE~~m OU~o~~~oTLCU~E ?min-~•ac-~-t-._c-•-~ra~m:-°°°m•`m ~ I-U~m F"'co0o-n"ro~'3'Sai~m i=-?a~o..o-o~'>-~a~ I J» ~ ~~-d> m >roU o m m ~ ~n ° o N ° o o.a m._ Ucn Uo.«-~•- o c U[C =-o v~- o °Q m ro~-r L>»mam~LU,U,L~~cwni~mLU,axi`o~owaxi0om°USo> cn¢t~ cwi~`°mro~~o>am~'>°~ cwi~vi-i~m~-a~mwd~r°na m ro mro ~ ro, m ~~y°mcnL`°moro nc~«~oamt~'.~~i ~o~~'.~rri c°°c'°'o-mo.'-T. c -p c ~ ro c:..,., c c ao m G o~ c._ c.- °o o c 'D O o~ p 1] C~ O •n 3~ O C O C7 R O ~ N O~ C C S N = ~ "O C O m:J m - w ro O O c G NNU O ce U•m E m o ~ m mL roa Z m jL t m ot~ ai o o~ m ~ E ° m ~ ° ~ c•N m c m mZ U mU m c-°~U ° m °~-U ~ c o ~ ~U c ~ ~ LL ~ a ti w Y ~ 3 o m~i c m w ro.X o u, `m ro m mU o ~ ~ mU ~ c m~ oa m c c m m m -c Uc oL oC caU'-c ma>, U a` c -T°~m m o o ° o ~ -a m m .mc cU~ ~ ~ a~°C7 ooU c ~ ~mU c oaU OCC a mo m m .ro m `c°-mo oyoE..o~o ~ ~a~ LYN o WT°o-o t~mmm m ~ ~ _m _m Z > j OL C O rower C C O } ~ ~~~F- oU CLN OU I- m O C C O .n C C Y C C p ~ O a-n 30 ~ m m C~ ~ W `Q ? C •.Cn m m U ro ro ro~ m ro m m ~ ~ L~ y ~ O C. O~ O O ~ m Ca O C O ro C ro m L ro O_UO ro c~ c p 0 00 Tm >'OQ~j ,n m' t~"O ~ ~ U F~ OII~a ro U m ON ~ ~ C CQ CN'C.C ~•nU C UN ~gS~LL~ N CL.-g O ~ O C m `5 a ~ C mC N N E Wmpro.nm~''L"mN ? NC~Om ~ O m O.: 'Nm-m~° Q~©CQOC C ~ gpOL roNa C~OC~ W (")-0 Y3~~D~+L"~ H~w~O.• UIIO~~~~~ 'cU~- ~ U m U m m E ~ac w L m T,~J o mroU- a ? o~ ~ °~U ro~tirn -mnt m~LLrn ,c mQ c Q.a= a ~ Oa m.- x ui ~aUa CQ cQ Q Q Uri a E Ey o-, o m~ ~U ~ a~°o~Lm.. c•n or.G°--.. m m~ U.~ c m mm ~ G-o rN(~J V m~(O ro^ ~ O.- ..L Ua C ro~ .U N p a c m C roL3~ C mL?~~ ro C C C'U= , U:=,~ r~~~.-r Ur~r-Omr-err r m.L..-O m O~a m E~"O U ma cCO p~ N~~AO u-'~ 47~iC10 U 2m W O00 O m00 m0 00 °O 000 OL.~ O Ea ] 0.. ~ o p N O O -O -n 7"" 7QC0 -0 CO(D m QLa ~ j c~rrrUrmrr~rUrUrUrr rF- o ° ro romU ~.aUUw r QU-~ m rom5 o_~r= m m ~ av= U~Qi- mUU !I I f r EOC-yc,yn Via, Ly°NNN~Y-Of ~.E~0>.a p.V NOrD LOI.=~`° N~°~.C in ~n 1J~ .".,ilL~ Ou~JOSLCOO ~°C'-~O~ Op TOy m3 Amy y: DC O` °y C ~ O1 am ~ ;...~...2 N~~ _O Zwo c> , Un~i. G.d~ and O ...7- c O. °'a pU~ C 2 a>. j aC o° ~ O ya Y' C p NcD~ OW.__. ° v. u,y_ 7y ONm ~00 . JN> UmvD a. E o A aEUN m _DyyNVOO~ y,u '~oc° a-N~ U°' -~~E`oo mU m~m =2o"om cma m_3v vc not ~ - to~~mc ~ °o_~mm wm mN v..a vLC mam ms c NV ym°A y mE m o ° u moues; EN`o. a ooh ms -L ¢7~c °'P N c m ¢ a 3 o c E o = o U f- y o ~ r m SL m~ n~` n ' m ~v c N°1 ~-m NL am a~> >s r. a'°" jc c _ E °n'o o-ON`m a - > a n y ~ Q .0 3 D m 2 c a c~_ U m N m_ O 0 1~ ~ O Tp N h y_ y Gl O Ul O. ~ gy m' C- e p c 0> ~ ~ D O N Z_ V U C m ~y¢ ctv Ea ¢ y ~c - m E ° c.Ea g ay E y m Em ~~?~m a mss jc>= y _~ao m cr,c m ° v a=0 y °-_v ° ¢wpp~c t0 r V° b_EU ~n a,oo ofi°`co~3mD °L~a~..o ~m N v,wDCO tom, ~L C°~,So~ c~rc ~LL~omai~_N `.~"`°mL u'¢w noon ~ m ~ ~,Eo woy >°c a.?N.:o o- - °~i:m ~~c_ o°yEm ° _ ~=~v c ='c>.-' z ¢ cE~E = pp mam °°~Sm ~'°~2vwE~o_ >'oa '•m ~v>Ea - `c° ^„c> c?;~m`°' cy-J°v L==mam_ O¢r mO oNCy y U t- `>,o o~~raoy=m amE o--Lm~ ~ w _ a?°womr V u,- > Lc-rc> o~,o may Tf ~ ~ a:w a.'O m3a um'~= mO° nm~'--~° ~ymOC,.> n_~m3-nVy ~n~>°_'oa =ate `~mNo, paO¢m^mam m V E-m Oocr w o£.c- ~mtm oc_ma vv, - U ag'mU-°o noot_ _`m°>.m 3ui _ - ~~aN y ~¢-i-N L]LL > w aD a D E m r m - U a r m v v E- E~ - a y _ o B.:° 3 y ~ ~ o ,v o ¢ z'n o ~ Omm~~ =0 wmE-c FOL Q3 TypmNmn,p 'Uy° -~OmN yt_C,`.iUNNL ~.°nF, ~~,Omy`°CaD >,NN - ~ - QOS mLLL y r No 3~ a-cr a~_O>,a naLL CF- v°C~~3 yUW a~ n v D~, a ? ~ Lcj woam O wNC Ol °i ~ O 6 wao n v,y~mQ F= m~T° - m.: ~j ua~~L Ca m~°-°c p>>^moN o oaf ~c U_°E aay°E°nc>oc o o, vo ~ n v y _ c ayr U ¢ E o m m N-°o 3 a ~ oa ° 2'o c= E a mam ww'i md>, n o~c o~-n o° ovay _U oa. cmi0~ Emm c o nv a oo mco >Z° yo _ mn~n ~°y u~mm mam E y ~-°'E a'o oo c ~ c c3oE Eoo ~ rc `nm UO danaa u~-i Sr ~ c mN3v _ m o _ _ on m ° _o°ac LE Um~y_ ro O¢wy m yy ,t pOa aw oQ Et nnm our °L v e ~o _o"m -E ~°>.n .o a ~.aZ ..mco Nmmm_ n mmn~u,o>= v U nay y yo vm - v oyo ¢n.UwotEo w m5~.c -Um~ °a nc~c Ear `v,m~nm5 $N cno apmm in mctc p1o noc3£v,=~v °c°~mn2m ~n ocE°o E' ?aObH=UU a V _ Q1 _ ~ S a p r~ Q d y Z c m~ a¢ ~ c a m y 5 OI,C m ~ ~ N C O~ N taco Old y C a ~Ly- O n D J L N J ti J L~ e=~ o S _ 2 p m y ~ ~ O U O ~ d~~ a `O L~ a ~ m 7o vo ~c am_m~ m cc-a aoE o ~~c= oa `oo m o y ~"oo Z a LL v~ Ja D a ~uE zc oyE`_ -isoam~oc on a mo.. yon s Ua u~aS~ u~a i0n y Occ~ ~nn^ ¢dy O ~ =OU~3 Oyo n ca tv rn c ~ c_ ~ s n z >°oQCE~°y °'oOS= E .c- 'a - ov Ot~N° a E,° `m'gt >,tE ~ cc'o ~m °`yo 4°aa y `'ao ~ ~U wE. ¢ tma°,bn ¢ w~°i ¢E~ wo.. Z a m~°c' ` N ~9E E:°c° mo Uc°~mmamn a E 'o a+°" a°'am> Dm OcroE i~ uOi mnvya Omy.°vo Ow ty ~mo Zo3 w ~N a'"~°a>'°y-m-°E O o~U a~~ > y a s v- ~o x co c_ ma°°~ o ONL ~UO~.. O1y0 ~ w_y vN~c°'-d~, °~'oW rW-~a y,w w°?_n3°Jm ¢m 3~ z aEi On >-a r yo aoc n~`n"~" ° a~m°aon_ Uny ~cq n vim Q~mrSovDOOCyi-o-~ i.E_ a~,._ E _v- m ¢ -o oNw Zmo6 E- _ ~N ¢o vvtN ¢ m z~° ¢o `o. c a~~t~y mm~'.:acac mw~y`ma ,anmvmLL Or my zNno W~~ O - omy~°~icZ wEomoocm mop UO°m~m~-°_o3nm'N my ~~QO'o E' LO_°'m >n nE-°°s' ~ mm°ac v,~ wN~~.a nL w~y.a'n'O aoLU, coE ~=y> UOm N cU cm~moa d~ = C7 mN nwaa poy ~ cam°LmdyLOamy ~o`o.o o°a aLT c'v_ m 3oyv t- a m w.=. Ec o pN°T E- m Uo oS' v ZO; ~ _ y y o n °roNyy° v3mo$m ca_ o° n5 a v Umy ~-cEm zpy~ no, ¢°Ec OIC N ~ W~~N` (J yN 3 LLtO N- W CU m ~ n _ mDD a0 tp°yvromE OL:_d~a Ofj ca NLD y _a p _ ~ yC_tvp y,na O W Chi U mm°no ,n-o ~`L~ g°o t-m-cv ~ _ `m a co n>~smo mayO'>`.~ oi0mmo~r mya = o _o m._ ~O ; o>~amroa c mt>ym~m~ e,n °zy°E~ `coot-NSr~a~`mt yp~ay-6~may PENOy3° m on oca~Ur. ~Da`m., mpw y~y° mO1m ~ ~m ZU10w o°m'~9E~c n any ax °mam O'mo°mm o o'- n-m`oao4o_iLm Q= ~m-a aryam .lmy' U s - - °~wpjo oa>wy ~j m w-im cm_ ~ 2 N ° ~ o E o n... a ~ y c E m N~ °m N N n y c s_` ° y _ d ~ r °'n° r=' m S= ma y z o y c t0 c o t E a c h m m O c E D ^ ~ d > ° ° oy°ma _n ~ca F°ac a~i F~~nN=nO1~m.coNmEc ?QOL~m°o~~>t~o ~va o~~~~~o Opa mt ~3°. ONyma~c' Owmo°-c'oi pOW~ OwLC ~~0~ yN ro..cD yt U ' ° o ~ UQO n ma w o. atm Uv 3c vmE c~jm3b vm U~oL° U¢-~ ~U-°2 ammo O1~ °s , a wdom'Lmm wNE~~ w¢~°o~L°m~md$°' HmOa-'c`mit „-a~ymd~ °m3 woooLO a m-ovo'~_ wo=°. dmo wO~m>c wo- wwt° o~tt .-o: na ~n C7U °~n'3E ° rn <n my v>¢ao..-_oc _ a:c m ~:~~,nn o°i a-c=a m°E `a r°- ~nv_ o.-c onx ~n°o °ii~_ oc n fnv °E o.3 ch ~nr m o m cnm°~ <n2ym w~... ¢~£u3dmt Of y~ W O N E mom` C NO Na "m N~ W O ~ yw 'N C c- L ~ °3 ~ ~o5~t a.o omi~m oDOCt ~.E Nm m<"m ~o gm=5 ommmnr omo~= - omc.._ t0cu 4w°EC- 0 0 o" ~ ~ = m m~ 3 a v o- Z m LL ~ O_ 3 ~c c D a° N a 2 E g 5 aop o °c'O o - y om y'3 _ ='m'o d o E °mL amd ¢ya .v; S`_°m ~ ,v=~ °4°`mam °ooENO3 ~ oo v-'m ov ° 8v E v c ~ ° m-°~ E~ ~ gym Ana-mo cncrL ._m n` ¢ co 0~-° ac c 30 ~n o Ana E'c E ~3 " 'nc ri~o °cammc ut - y~~ v c O~oE macic x o- Nam cm'ov E o mO m°LL - am- oo Nw a~- m- m w co;_an ca°'- _,>FS y ~~~om .m°-"c ~w oid m- °om- ac O.~o v > m~msp°aca 2 S _ oym~ Z oc ro _oo ~ - ac yU b.. a o - ~v- - Ev n ~ w~ mE vi vs d mE0 omo`o oa9: v .U t¢u ° o oEooL°y O ¢m°'m=~ ~ ?'o o vU o~ n'mvr a`y' oa yin ~OL~ a O c ocn z aEE m ~Nm O Em w y a ~ ~ LEp"a o0 ~o° O ~ ocL mE m ?~NaT z-oE3ommy,N wv--QL O4a- io°om m- N off..- OtN p o zDE3N~ c n p oO w _ O oom ° y ¢ °ro mn 3nNC _ nm zy"_m`m O~c`c°mc O - ym` ow w~v°i ~O >~~y 7 =mm z~U ~~~m ; xLyroc wN2cct nLO ~-v `o - ZO o~`o`vm~Ec K~ - - U~ _ o Uva orC7~ m.'~mm wNZc~r ` cno N mm~ ¢ Nm~._ ?~acmn°3 o so m w a3~ov so`_'NV,3o ~n cn '0 ~j v o Nt ~v myo ¢ m zmc °i Noa~ m ~ °'~~na zamocny ¢ °c -vq vm yo bo ray N~° ~ y ..E~_ Ec~id?d ' mom why o v wa w~ o o w=mam m v ac n oa U n - r > v o my_cm Ey wO y w°' o Eaiov °'E 3,>no m m ~O E~ m a`_ w yn oU LL _o ya .>m ~-OC ¢ `O ~ m,°o m pco v>. y N o O oc c O~y ~.u ~ w or e a ~ w ...o od- LL v yE pJ"c°~ m c Ovv ° m' ~ O ~ Ev_Q o Oo nnyy wE w°-' U =v- nc m vUi Nd,-°~~ 'O3 v o nN m Jmt aNmnoc~ ¢ .v -t °'cm ZLL"mm r_ Oom =y s=v a -o o m w a o. A m y ~v ~ _ a t Z c c m n O o a _ y o m ~ o r m w d U N a y~ i o~- N n E 2 . omL m _ .3m 3 o~ a Lm v n>y Noc ww L`°r tea= ~c - 3 20 Lo ga'E°~ ~ ND ~,N Ny oa'RNanmc LLLL°Q `oy~o~ °.y__ wyH ~z`v°' > .u>~~~ n ~aEm ~v ~ Noy- y~ o~~" uyi=y az °~o aD3° m o S E ~N y`u-? v~~ vc-0oc_y aZcO a; ~ ~c£ ~ Oa o~- ~ r mo, O ° o mL- Enmov ocm °m° ° °=om- Simms ~E Omo o y°c omc N - - Nyv ¢om zms> 2>.~ zLLr>°'d zii9 da-.mr ° ZvmoooEm` zmmxc _o~ma °o=yv ow~¢ E F.3c Esj ~ ~ v~y~=~ mE ~z-v O 'o O N Oc~i Oni mnma- m - c ` om - L m.m 'O z¢a r oo E zLL - a ° ~ z ro z zLL~ g ZLLn ma ai ¢o~ m °o~ m r Oc Q"rE.E ~w 'Emo _ _L=Dw m - nom. m_d Eyo~ a°~m F-mm do a co F-iq oc v 3; c~mc _ N oN O NE O o ¢z=v O o O O~v ~ooc Ovi o am> w`t3~ w=m Uoo3yn U~o yS °1 - ~o U`uE c U~>` _->5> Uvo°>om Uac=mE~ ~w~~ U~- v Ut Umo no E Vu'crv w yoN rv m3o a c6=; 2r~ u>L V, ~n cn~_°~_o uwi-°m'o L°~5 °~>'o3m uwi ~nr cn°o`mu ~>>O `c s°_'SN° ~a~,c ~°c_ vwi°rn °3~n° °?ti= ~c cv,i-°D ~.N rwi~°~~S~USa vwi~moa5 ~ _ O mE~EtEd ~a U~~ wvm ~=v c~ X01 mcyi me om ° -yt N= yc`c murmN~ r.-m= y w or=o2~ N 3c `m i- t jmv ¢o ~o~ un oms m z `o yo-,~ v o ,c~a, o~ rc_. o x my ac O.~N ym_ ~o a y N m a 0 Z N p`~ Q E N;'- i~ a-~ a -O n° O ~ a 9 N ~ L E U L O y N- 3 _ N Uf U O1 Ly' ~nN ~(nOONm yN ~D yl]O ~ N,n N Oa N UOC 6 '~D °~my ~ ~ Nro ZN ac N~dN y0 aO,nO O ~ Nom. °~N N~~ y arc a W s O ~L E Nm r ND"mO NEE `O Oa c °.C 1- ~°pNN Z[Aa 00~ N c7y a_-ao gm. ~ r-o ^!3-~>.D to aE y ya m Ow a mam S yvEy _E3 ~mm o ov a..m3o _ p'-Edwo m--~o ~ ~ 7~j '"¢ov m._ `~'~m ¢E ~mm`om w ~ ~0.~ yrj c w~a~ m °mcO a ~ a2 p OPcoN c_= ON jm -maw= ~v ¢.om° GNV ¢joJm ¢ w~ „mba o__°n _mam ~~U °s,- ion w cED Za `o ccm~~ <"'.-o.. Wz myo~ wz n avi ~tiomEo°c c a w°_' r[m= a ° L m awa ~ m v E y y_ _ y m w•_ a~ Na T LL mz car rm j°- -=~~mo NOOy2~o ~nO ~y m jn `m ''"E ~cnEm a w OO m; 7v°m ar mc-a,~ Oom ~ my UQ v~ A ay x ~ y c wo'w 3m°im; E' N om ..NO 7~'-m= p Omtmm~°~E~ O ~ O Q~o Eo O` Oo m ~yy ZU Vc "3 U v ¢ yO pN.>t 00 0!-°0~ pp ¢ m °o m~n~d OSE° U y ¢L O1a a O d zO s.o zy, ~n 3.;; c° aLV '~L y_c t3LNE c.> z °f~m Z,`-ov° Z i am C7 m~ C?~y ¢`ynm "n;omv>~o Uy~m ~c ° fact c ~n` wy -E w~O¢-gcmnn O.°y Ta ZO D~o yo ZO = o E O ~o>. a mE y c,N E°J UNp ~m~ p2 ~ ~ y LL a E cony c;_w mU-vo°- m i ~c°8 ymoa-aai r- y rye ~Et O zwE~ °v_ ~ °.°U yZ3mv a m m ~.roE U y~ c_ m; .-fn - m moa Nno in°-O O ~ a ~ m ryc LL° °AV ~md~r~a nmy par O¢ c`°~ O- m c~~°m'm ~ymo N E~ c =_v N¢t. u~mr 3 ~~mm - N Ny ry E Ua U~`°'~ `m Uam 9n°~ U¢ ti(n c' c~mu N~ y y v¢Uy ,_3 _NQO aW .~,`u N N__ o~ ~~mt " ~Z.-c_cZ ~ o- m z. ugc o E <n _ mm onM ~O Esc co r_-° c zm° oc? o~° `8 no _°-'N°m ~~Of c-oN Oaya~io ° Q~ rnOcyOC~v E>,nc Si¢-~ °m¢UO rnNroEv,-a o~ y rnO ~°-'-vo S.~m m m O°'c oyo- ~ ~ ~~y-~° >03~30~ UAL °-'o~~ rg in o`~T°' ^~n N a-p'~-o_v i°~ U U -cc oa ~ ~ v ° >>,3 vc ~ mo_cy zp2 o m. z zg_j z~y my~ = y; z ~°v ~ zsy Z ~ a3_ zm`> z ~ ,w~>;E z"~~y >ai z¢ 9z`_ z~~ z5 oLL oa o o - o o-~ of _ _ tom _ ~ _ ;`o om ayo cmm na a ° ~y"yv cn =o Oc Z _ O 'o O O~i ON moo.^m mt Ormo~~O= 00 v yo 00 U U~Go~°=ymm woo ¢E a° wxE~c o' ~ w8 U we O U~ Uoa Uu e'-yn U cEt_°_ Zmao~u,o r-p~oo u? O °_b >,aN w¢<jE w~5- w¢~-c E~ w'~=0~ O - - o ~5 3 w c_j v w`$ p0'=o U U U no.°r dm v:ZO_a ~ m ~n LL_.m cnLLam ~nammu~ E ~n S~°~,"u ~nmm?3~`..° ~n u>m ;~c~._ ~n_vr ~n ~n %n ~.=~=~o ~n-L°m o3 aa3m in OU~a'n vwiam ,~'¢°'oA mn in¢ 1