Loading...
HomeMy WebLinkAboutM01-0045TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Job Address: 400 E MEADOW DR VAIL Location.....: TYROLEAN CONDOS DRIVEWAY Parcel No...: 21 ( O1 Project No : U WNER BEN� TOBIN CO LTD 1101 HILLCREST DR HOLLYWOOD FL 33021 License: CONTRACTOR J S& M MECHANICAL P.O. Box 9338 41000 US Hwy. 6&24, Avon, CO 81620 License: 280-P APPLICANT AROSA CONSTRUCTION, 2648 AROSA DRIVE VAIL, CO 81657 License: 04/30/2001 Phone: Permit #: MO1-0045 Status . . . : I5SUED Applied . . : 04/30/2001 Issued . . : OS/10/2001 Expires . .: 11/06/2001 �I �� � � <l-� � s �_ � � � t ��� ` 04/30/2001 Phone: 970-390-1138 Unit 2, Eagle-Vail INC. 04/30/2001 Phone: 970-477-2611 Desciption: Tyrolean - replace concrete driveway with heated pavers Valuation: $14,000.00 Fireplace Information: Restricted: Y # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0 *r*a**s******************�***►*►*t*�***********r*s*►►***�s******►r*** FEE SUMMr1RY ■*r*****a***►*a*sa******arr*►*a:xa**a*****xaaa****r*►aass*r* Mechanical---> $280. 00 Restuarant Plan Review--> $0. 00 Total Calculated Fees---> $353 . 00 Plan Check---> $ 7 0. 0 o DRB Fee---------------------> $ 0. 0 o Additional Fees-----------> $ o. o 0 Investigation-> $0.00 TOTALFEES--------------> $353.0o TotalPerniitFee----------> $353.00 Will Call-----> $3 . 00 Payments-------------------> $353 . 00 BALANCE DUE---------> $ o. 0 0 ***as**+**s*rtt�*****ta*aa***a►***te*r**********�e**a*:�*xx**s***+t**x****ert�s.*s*******��**x***s**r*****�►a►r+.s******ss�**ax►s**rss******e*s****■ Item: 05100 BUILDING DEPARTMENT 05/03/2001 CDAVIS Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER SEC. 701 OF THE 1997 UMC, OR SECTION 701 OF THE 1997 IMC. Cond: 23 (BLDG.): INSTALLATION MUST CONFORM TO MAN[JFACTURES INSTRUCTIONS AND TO CHAPTER 10 OF THE 1997 UMC, CHAPTER 10 OF THE 1997 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 8 AND SHALL (BLDG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CHAPTER 3 AND SEC.10'll OF THE 1997 UMC AND CHAPTER 3 OF THE 1997 IMC. Con�: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): DRAINAGE OF MECHANICAL ROOMS CONTAINING HEATING OR HOT-WATER SUPPLY BOILERS SHALL BE EQUIPPED WITH A FLOOR DRAIN PER SEC. 1022 OF THE 1997 UMC, OR SECTION 1004.6 OF THE 1997 IMC. ***.**.*.***���*:*..**************�**��.•s*.*.■■*s*****«**:«**********.***.*■*****.********�*.*»***.**.*******************:*****,***.*.�*.�*.**** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2138 OR AT OUR OFFICE FROM 8:00 AM - 5 PM. �/I n 1 4 .�' � � SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNE ******************************************************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on OS-10-2001 at 09:55:47 OS/10/2001 Statement ******************************************************************************************** Statement Number: R000000722 Amount: $353.00 05/10/200109:55 AM Payment Method: Check Init: DF Notation: chekc # 4672 ----------------------------------------------------------------------------- Permit No: MO1-0045 �pe: MECHANICAL PERMIT Parcel No: 210108252001 Site Address: 400 E MEADOW DR VAIL Location: TYROLEAN CONDOS DRIVEWAY Total Fees: $353.00 This Payment: $353.00 Total ALL Pmts: $353.00 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111300 MECHANICAL PERMIT FEES 280.00 PF 00100003112300 PLAN CHECK FEES 70.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 ----------------------------------------------------------------------------- M01-0045: Entries for Item:390 - MECH-Final 15:47 02/27/2013 Action Comments By Date Unique_ Ke AP Snow melt boiler in operation, finaled today. JGG 01/28/2009 A000122 333 Total Rows: 1 Page 1 ' "� _ ' APPLICATION W a�-B CEPTED IF INCOMPLETE OR UNSIGNED Project #: _ p��l - d I C� 9 6,(� �G� �' Building Permit #: 3� Mechanical Permit #:1'V101- O � � � i� S � 970-479-2149 (Inspections) T n W N U F Y A I L TOWN OF VAIL MECHANICAL PERMIT APPLICATION 7 5 S. Fron t age R d. Permit will not be accepted without the following: Vail, Colorado 81657 Provide Mechanical Room Layout drawn to scale to include: ❑ Mechanical Room Dimensions aU ❑ Combustion Air Duct Size and Location ❑ Flue, Vent and Gas Line Size and Location ��� f ❑ Heat Loss Calcs. � ❑ Equipment Cut/Spec Sheets CONTRACTOR INFORMATION Mechanical Contractor: Town of Vail Re�. No.:��/� Contact and Phone #'s: JS & M MECHANICAL, INC. -� M�flp°'U" � KANDI SMITH 390-5514 Contractor Signature: . �?� COMPLETE VALUATION FOR MECHANICAL PERMIT (Labor & Materials) MECHANICAL: $� 14 , 0 0 0. 0 0 Contact Eag/e County Assessors Office at 970-328-8640 0� visit www eaale-countv com for Parce/ # Parcel #(Required if no bldg. permit # is provided above) � �� r�� �S� � � j Job Name: TYROLEAN SNOWMELT Job Address: 400 E. MEADOW DR . Legal Description I Lot: Block: I Filing: I Subdivision: Owners Name: Address: Phone: Engineer: I Address: Phone: �iled description of work: INSTALL SNO4dMELT IN DRIVEWAY AND INSTALL BOILER IN MECHANICAL ROOM Work Class: New ( ) Addition ( ) Alteration ( ) Repair ( ) Other (X ) Boiler Location: Interior ( X) E�erior () Other () Does an EHU exist at this location: Yes () No () Type of Bldg: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial ( � Restaurant (X ) Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/Type of Fireplaces Existinq: Gas Appliances () Gas Loqs () Wood/Pellet () Wood Burninq () No/Type of Fireplaces Proposed: Gas Appliances () Gas Logs () Wood/Pellet () Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes () No (� ************************FOR OFFICE USE ONLY***************************** Other Fees: Planner Si n-off• Acce ted B• DRB Fees� i Date Received: F: /everyone/forms/ mechperm ►o 's -� o�+� i � �e, �� �t � �� �— U� �� —� �'�� .� �'�i� � •�r M. F � �� ��� `� �� � � �� . °�0� � � cx.���;de t�.�a E � \�i �o�- c.�at� 130� I�` 14• 3 ='" T 3a" ��, � � ��� �� �� � 5l) ow Ike t f a� �� �v i � E � E �� 3 CF ,r. .��,� � v`c , a�' x' �` �� i F-- 14; 5 � �6�1,�� �- � � � 1�.�5T � �� � ��/ ��� � � C � ./ �� v�O��Ll���" ��c71 % � � ; .:� � } �� y�,'" �/ � � � � ��:�� � � a _ � , , � � � vocu►u K o r �cv �1/1 6 l.G CL��9�1lC�S 6 � � 0 � � � �: � . n :' , ,! � � . t. � 1 ' t: ���'�.L._t._�e��.l�i� �1 S(� FT �Spp �3"[ITH ! 8AQ00 Hf3II.ER lN�'I1T 13TLH 3�07�1 �'T OF 7GBE Z�p LOOP I II+�GTF! 13U A� Cl�' 1�(][)PS g T�O�['�L IiPM i2.3 G�7yi PQt LC�l7P t .5 �' (�7'j �.QQP 11 � t�'? �S � S11+Ot. l2 Q 'CCfT.�L P[7►(�''I; �3 � SMS � 3iVtR Pi,F'� S17.� 1 lf�" � ARE.A TIJBE SPACiNG 10" r t9 TUElNU PtPE 517.E = 5111 �• Z W ❑ } � CC Q m � � c7 � � � O � � M 1 � w Q