Loading...
HomeMy WebLinkAboutB06-035608 -09 -2010 Inspection Request Reporting Page 3 7:13 am Vail, CO _ Citr Of Requested Inspect Date: Mondayy Au ust 09, 2010AssignedTo: JMOND 2AGN Inspection Type: BLDG Inspection Area: CG Site Address: 184 BEAVER DAM RD VAIL 184 BEAVER DAM ROAD A/P /D Information Activity: B06 -0356 Type: B -BLD Sub Type: NDUP Status: ISSUED Const Type: 103 Occupancy: Use: V -B Insp Area: CGOwner: WHITE ROCK BEAVER DAM LLC Architect: RESLOCK & SULLIVAN LLC Phone: 303 - 773 -9578 Contractor: WHITE ROCK Phone: (914) 260 -9070 Description: NEW CONSTRUCTION OF A NEW PRIMARY /SECONDARY RESIDENCE Requested Inspection(s) Item: 90 BLDG -Final Requested Time: 10:00 AM Requestor: Phone: Comments: 390 -7303 Assigned To: JMONDRAGON Entered By: MHAEBERLE KAction: Time Exp:Comment: Partial Cof or b side onlyComment: 1. Mech final approval. 2. Need PW approval. 3. East stairs max 7 3/4" rise and no more than 3/8" difference between treads. 4. 2nd bedroom guard shall have max 4" openings in guardrail. 5. west stairs max 7 3/4" rise. 6. step in garage shall have max 7 3/4" rise.Comment: repair steps to garage. 1 t Inspection History Item: 10 BLDG - FOOTING "Approved" 08/09/07 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: 10/05/07 APPROVED FOOTINGS, NO PADS IN PLACE PATIO LEVEL NOT READY Inspector: shahn Action: PI PARTIAL INSPECTION Comment:WEST SIDE "B" FOUNDATION AND 3 PADS OK FOR REBAR. 10/23/07 Inspector: shahn Action: PA PARTIAL APPROVAL Comment:FOUNDATION REBAR AS NOTED ON PLANS. 07/11/08 Inspector: JGG Action: PA PARTIAL APPROVAL Comment:Footings and piers ready for concrete. Steel OK per plan. 07/31/08 Inspector: JGG Action: PA PARTIAL APPROVAL Comment:Footing steel is OK. UFER bars shown on both sides. 11/12/08 Inspector: GCD Action: DN DENIED Comment:NO PLANS ON SITE NO ONE FROM 3J ON SITE LEFT MESSAGE WITH JEFF. 11/13/08 Inspector: GCD Action: PI PARTIAL INSPECTION Comment:UNIT A EAST SIDE WINDOW WELLS 06/02/09 Inspector: JRM Action: AP APPROVED Comment:APPROVED FOOTERS FOR HOT TUB /SPA AREA Item: 20 BLDG - Foundation /Steel "" Approved "" 09/14/07 Inspector: GCD Action: DN DENIED Comment:COMPLETE SET OF APPROVED PLANS REQD TO BE ON SITE 09/21/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: WEST SIDE FOUNDATION WALL AS NOTED ON PLANS 10/16/07 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: PARTIAL APPROVED AS NOTED IN YELLOW ON FILED SET OF PLANS 11/18/08 Inspector: JGG Action: AP APPROVED Comment: Foundation walls for window wells are OK. 06/04/09 Inspector: JRM Action: AP APPROVED REPT131 Run Id: 11812