HomeMy WebLinkAboutE10-017309 -13 -2010 Inspection Request Re Page 13
9:09 am Vail, CO - City Of
Requested Inspect Date:
Assigned To:
Inspection Type:
Inspection Area:
Site Address:
A /P /D Information
Activity: B10 -0173
Const Type:
Owner: TOWN OF VAIL
Type: A -MF
Occupancy:
Contractor: ROOFING COMPANY, THE
Description: REPLACE ROOF
Requested Inspection(s)
Monday, September 13, 2010
CGUNION
BLDG
JLE
2189 ST MORITZ LN VAIL
GORE RANGE CONDOS
Sub Type: AMF
Use: VB
Status: ISSUED
Insp Area: JLE
Phone: (970)887 -0104
Item: 90 BLDG -Final Requested Time: 08:30 AM
Requestor: ROOFING PAN HE Phone: (970)887 -0104Comments: 485 -93
Assigned To: CGUNIO Entered By: JMONDRAGON K
Action: W Time Ex
Comment: FLUMBIOU V NT NEAR RIDGE ONwEbTSIDE NOT EXTENDED THROUGH ROOF (12" MIN) AT
1OOF JACK APPEARS MAY HAVE BEEN BROKEN OFF
SIDE TALL STEP FLASHING AT ROOF/WALL INTERSECTION AT LOWER ROOF BY STAIR EAST
3 COUNTER FLASH AT RAILING /ROOF INTERSECTION AT LOWER ROOF BY STAIR
AN SEAL NAILS IN FLASHING AT ROOFIWALL BACK LOWER ROOF AND CONTERFLASH AT WALL
2)
SHING
Inspection History
Item: 90 BLDG -Final
08/20/10
Comment:
Inspector: c Action: CR CORRECTION REQUIREDALUMBINGVENTNEARRIDGEONWESTSIDENOTEXTENDEDTHROUGH ROOF (12"1 P
2 IN STEPFLLASHATROOF/WALLLINTERSATLOWER ROOF BY STAIREASTSIDE
3 ) COUNTER FLASH AT RAILING /ROOF INTERSECTION AT LOWER ROOF BY STAIR
4 SEAL NAILS IN FLASHING AT ROOF/WALL BACK LOWER ROOF AND CONTERFLASH AT
2) ALL FLASHING
REPT131 Run Id: 11911