Loading...
HomeMy WebLinkAboutM09-0273Oct -osgt- 6& Cc 08 -04 -2010 Inspection Request Reporting Page 19 4:04 pm Vail, CO - City Of Requested Inspect Date: Assigned To: Inspection Type: Inspection Area: Site Address: ThursdaJMONDRAGONust 05, 2010 JRM MEC 4470 TIMBER FALLS CT VAIL UNIT 1502, TIMBER FALLS A/P /D Information Activity: M09 -0273 Type: B -MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: JRM Owner: 1502 TIMBERFALLS Contractor: CRYTON INC Phone: 303 - 789 -2740 Description: INSTALL GAS FIREPLACE, GAS PIPING FOR FIREPLACE AND OUTDOOR GAS GRILL Requested Inspection(s) Item: 390 MECH -Fina Requested Time: 11:30 AM Requestor: CRYTON IN Phone: 303 - 789 -2740 Comments: 303 -503 -2 Assigned To: JMONDRAGON Entered By: JMONDRAGON K Action: Time Exp Comment: IP AT EXTERIOR VVACE7 FFI REPLACE GAS LINE 2 CAP GAS LINE AT BBQ, OR INSTALL QUICK DISCONNECT Inspection History Item:200 MECH -Rough12/21/09 Comment: Inspector: CG Action: CR CORRECTION REQUIRED 1) FIREPLACE VENT NOT INSTALLED, REFER TO INSTALLATION MANUAL FOR VENTING INSTRUCTIONS Item:315 PLMB -Gas Piping12/17/09 Comment: Inspector: cg Action: CR CORRECTION REQUIRED 1 PROVIDE SUPPORT EVERY 6' ON CENTER FOR PIPE 23 PAINT BLACK PIPE ON EXTERIOR EXPOSED TO WEATHER 3 NEED 10 PSI AIR TEST ON GAS PIPE 12/21/09 Inspector: CG Action: CR CORRECTION REQUIRED Comment:1) COMPLETE ITEM 2 FROM PREVIOUS LIST 30 PSI AIR TEST OKAY ON PIPE Item:340 MECH -Misc. Item:390 MECH -Final 07/07/10 Inspector: c Action: CR CORRECTION REQUIRED PIPE AT EXTERIOR WALL AT FIREPLACE GAS LINEComment:1) CAULK GA%2 CAP GAS LINE AT BBQ, OR INSTALL QUICK DISCONNECT REPT131 Run Id: 11795