HomeMy WebLinkAboutP10-0173 (2)12 -15 -2010 Inspection Request Reporting Page 48
4:54 pm Vail, COO - City Of
Requested Inspect Date: Thursday, December 16, 2010
Inspection Area: JLE
Site Address: 3035 BOOTH FALLS RD VAIL
A/P /D Information
Activity: P10 -0073 Type: B -PLMB Sub Type: ASFR Status: ISSUED
Const Type: Occupancy: Use: Insp Area: JLE
Owner: ADAIR, KATHERINE D. & JOHN
Contractor: TROPICAL HEAT INC. Phone: 926 -3126
Description: ADDITION & REMODEL: INSTALL UNDERGROUND & ROUGH PLUMBING FOR TWO NEW BATHROOMS
Requested Inspection(s)
Item: 290 PLMB -Final
Requestor: TROPICAL HEAT INC.
Assigned To: JMONDRAGON
Action:Time Exp:
Requested Time: 11:00 AM
Phone: -or- 390 - 4222 - GEORGE
Entered By: SBELLM K
IL
WILL BE
REPT131 Run Id: 12302
Inspection History
Item:210 PLMB - Underground Approved07/02/10 Inspector: CG Action: COND APPROVED /CONDITIONS
Comment:ROLL -UP WYE AT TOILET DRY VENT TO ABOVE HALFWAY ON WASTE LINE
9 PSI AIR
Item:220 PLMB -Rou h /D.W.V. "* Approved "*
07/09/10 Inspector: Martin Action: AP APPROVED
Comment:
09/21/10 Inspector: mdenney Action: CR CORRECTION REQUIRED
Comment:washer box standpipe shall extend a min. of 18" or max. of 42" above the trap weir
DONE IN BACK OF CABINET AT FINISH.
Item:230 PLMB- Rough/Water ** Approved **
07/09/10 Inspector: Martin Action: AP APPROVED
Comment:
09/21/10 Inspector: mdenney Action: AP APPROVED
Comment:pressure tested with working ressure.
Item:240 PLMB -Gas Piping ** Approved
09/21/10 Inspector: MDENNEY Action: CR CORRECTION REQUIRED
Comment:GAS PIPING IN NEW ADDITION NEEDS A 10 PSI TEST.
09/22/10 Inspector: MDENNEY Action: AP APPROVED
Comment:10PS1
Item:250 PLMB -Pool /Hot Tub
Item:260 PLMB -Misc.
Item:290 PLMB -Final
WILL BE
REPT131 Run Id: 12302