HomeMy WebLinkAboutPreliminary Test and Balance Report 12-19-2007 C O N S SHAW T R U C T I O N JOB# 1674 H rco3 AT VAIL SQUARE PRELIMINARY TEST AND BALANCE REPORT December 19, 2007 The ArraBelle at Vail Square 675 Lionshead Place Vail, CO 81657 BTC SERVICES 3025 South 3600 West West Valley City, UT 84119 PH 801-974-5911 FAX 801-974-5913 SHAW 760 Horizon Drive Grand Junction,CO 81506 Office 970-242-9236 LETTER OF TRANSMITTAL 0 Fax 970-241-5618 CONSTRUCTIN Arrabelle At Vail Square Project No: 1674- PO Box 5086 Tel: 970-476-0454 Vail, CO 81658 Fax: 970-476-1219 DATE: 12/21/07 TRANSMITTAL No. 1343 TRANSMITTED TO: TRANSMITTED BY: Charlie Davis, Bryant Smith, Senior PM Vail, Town of Shaw Construction LLC 75 South Frontage Road Tel: 970-476-0454 Vail, CO 81657 Fax: 970-476-1219 Tel: 970-479-2142 Email: bryants @shawconstruction.net Fax: 970-479-2452 SUBJECT: Preliminary Test& Balance Report ITEM DOCUMENT COPIES REMARKS 1 copy of each 1 NOTES: Preliminary Test& Balance Report for your files Required accessable Parking & Shaw Staging Area Plans for your files SIGNATURE DATE CC: , t i cf' C ,........ 1 1 v 1 , vi ci kJ i , t... CY J N , - i k...,, , „--/ / 1 00 ‘ . ,iii , ..._ ..... ..... ,,,‘„, ,,,, s ,,,, / ,...2 ,,, , . ,,, ...;,.....„, - . .j . 71.= f' . \ ------i r- . , , ,''',/,-//i •.:4 -, { - - , _ .,_______ 1 T: -:-.• . : ____ .. , , jr---,, ‘ , X g' \ '4 Nil a i C \I. -; - ..... r --- - 1 -,- cr,. il I r - , — , .... I i 1 C .ZS• Cti c...1 --.-7.'' --'? It = 3,,....._, > ft\ V 1 i 1 MR 1 "- *- _i V ' t _,.: , _ i 1---- ';- — --_ : ' 4) iz . ,. • ., _ . ,7 1 Fh 1 t ..‹, t = I _., i 1 .... . _.• -, %W. /---11 C' ...............-. .. ( , ' T .,_ 14,. › 2----1 , ; a , . ,- , , , • ..-- 1 , i .--.. ..7--- —7-°-:a. .-- --.1-- —7'14 I--- 1 •" . 1 eass.p,esom.ga TI.,afomeolorge „wows I, § ,_- 1 i g _ 1 =1 , I i -- - --- i2 t ....3 ■3 FI ■-:, 1 _ 4 :..-.. , ., ti, z .1 in .1 --,...7 .--ft 0 7 -- 0 . 3. \.......," ...7..,-..' '=' •1 I, 3 1 '. 3 1 i i 1LT ---'L" 7. '.: L.....- .. I -.-= - --. ,1 T ll I, ; —i.;._. •.^..-4 - I I I 19 l.,1 1- 'r- . ,..': ...--,---,,-----...„ = j - - - - 0 ":7 ",,,,.........*:: • 3- - • ./ 1 I . — L _fj I 1 _ •,.,,,,I, o• p ° p C c' '''( (Si .• .... ,. C .P t- ._ i t . -........._ •--, .) ., ,,,,•.,;:,..5:-,,I- I: ,-.5.15, , '• c' 1 it- 1 .._ v, c5; ,;;;„ ,,,,,,, , 1:5.,,,' ti,i i.,..„. .,.; •555/;,;,,,, 1*-;___-'1W—_,-*1 ;,51 , •„,,,,, ,,,4).-, .., ",:-'1'.LL;Tot-,V;''' i rt \ * „•'. .:-..'.;:• •, 11,, kR3 L.,,,—..,_-•,..-,..1,..1 ,,,,..,,,, I i•• . 4 , - - ''',1-'4.• '.''!- *;,..4'11 -, ,, ' • ,, ... -,.'•!--; .,-...-- _,...._._,.--.:7,_-_7_ , l'i -:!!• .,,..-, - ?--, ,;•., . • :••--,,---„5 . _. '•55 ! • ■ . 5 . t, „ I:H. :: :- 1 ...i ..„ 1 ..,,, •- . - i ',.41 t' ".r-1 ' ' 'r • , .''' ;,' :,: i •, • .., ,l- . .7,.:4 ■ L............._.... -7--' , '',I ,L,.,..,,,-AL 71 1 -.......” 11,-.. L-:1 Ili". P.'''''' — "„,.., . F — A ; .A. 1•,:! i A 75, : - : tr‘- ri. ‹ .‘,1„---:, , , : t,„0 , ..-.71.:-:.,,, . ..,' ,,, / .,:', ,... / r Fr-,,•,:-. --7.i5i ----,1,- i.-- : .13 3>-----,-.---=;.=.------•••: , ' 1 ,, ', - /" r FtVi.J.: ::-. '''' •' 1 ' - .'''Irk''''':. g ' :=E: ..,.7., -, ,. -.1;', ..-i ,.-.74-,;ikil-'''il. -i I' '! P ,,,,, -:.--I''.;:::..f: .,---:,:.... t-.77-•.:Li....._:_ =,., -- ..7, -' il t-1 -' 1:'11---1,,.:,, I ::: -7---- -i.,-.....i. . (., ..-A .,7-'' ",..:: • , it , , . t , ,-,..,--, .. ..., .--,".1-Thp.L.:tr:' 1: : .,- i : , h. V.:,...,.:-..5,........:7,--...„,,,,' '---, .,. I ,.....,s,„ ,, , „,.,.. ... _ _. t , .,.._ ... ,....L___ _ ,...„ .,. i ..t ,.„: .f .,,.„,..1.—^ r"-7,.; ...-. ,, ..-- ‘,4•2 ... . • :, •-5.N. ,,,T.- - .-1 ''.' -- ..:-....,-..4 -......* F. , 1 pi,-• 1.,, •-,,, , --------t- , 5,•-•-- ':P '-..."-4' ------. - ---- •:!-z ;--7..i• 7 :.,4 ,, ',,t '. -t'c.-..,..2 "5... ,'''''''''''•-,-•-71 • '.\\,..., - .. i ;; -I. 1 .... •."/ . , f' ..::, , ..... s„......,. . 1 5 ir...._--, :,--; ;,,,,E.; 7; , , ;ic- ,1; I■ :.7”.r2. ' ].-L,,,....Si.:7771-'.., •-.. t. ';'' ''-'1 -... :;:."-...:! '''-t.,^.k 1 g : .: :- i •.•'''---i T.L.,if.... ...t.,,,, .:..-4- .-7 •ew ,--„: . ., L :-.. •—--:, ... : ,•,,—... , ., ,.,....::r. •,..k 1 11 I., 'y',,,,;/-7-'-',.71------,;-&--7,-___._„„, ..., '''.- -: -1_77.: c _.1" •:4;,', ',114',-ID-',„:::-......,,-t.:.-1.--': . I€"' , - ,-;..-„,,,.L,, 44. 1; ', ,...,:,;,; ...:.`....'..;--777-777-,*------7 ;''; -. ip, ,.,,,,,- ;,;' • th ';': ';.-1.-14.4-,-;iM!,--,,'•::- ; "1 i 1 - •- , ; -St...`i" :i L....., gi :- mi• ii ---,..:-.‘i-- -. -,...J -. „. : I a..7. -=' -------7.-- ' '/ \ , 3, r',ii E-4:71 :::::i,, e T_L:I t a• tt:i.---i'''''-''','''' '7.:77.TE7 ! ---':.-4 t; i 4 /,_.: .______, ,--14'i 1 '-, - —1 '1' - 1 1.; . *.1 ------ ]; - '17 -7,71-;;-,',' -,,, -"1 i : -,-,•,.,...., ,-;-,..:-.-:„...-.- - ..'::-.• •-.'..:,--:',---'- •.._.-- if ,g I :---.. r-- ,•' -,- ;,•-------------••L .........- r 1' ,..,,r,;.:. I-'''-, ,• 1 1'1'.=•”'. '.;t;':;;;;;:::::.-;.,';;;:',.::';'',"...; :"...,'"•,,Vr:;•- :;;; ;Y-e•;,,'%),;•';'.4:';;;;;;Til';';-,;;;;-1, , .. , . ; . ,,.2r..... ,, . ,.::, .., 1, - r ,‘...:. ,f-,•.:.,-:-,-,.,;" r..-,,,,,:-.,•z,.,,',' - .1.1;:vg.,-,;'0,-,.•P-7,-,"'"-',4: .. ' I ' - ' -- •-- - ', ;--• • 1 '- :'7:-•:-,,.-.,, In ly.;"'- ,...,,,,,f,r;,,,,,,,,,,. '.I :_". .,,:-,"„ _ rl; ''I . !r• ; , ' 1 . ' ; , •- : i ;;;;-''„',', -,;'..,...;-'•;''''; ''' 4:::.. ;., : =i., 0 1..;;VE2:N;,;•,..'..-;-•:'t•-;fr "L .;;i1, -; : --- --•.-------- - f!jirt TOWN OF VAIL V- Vail Fire&Emergency Services 42 West Meadow Drive Vail, Colorado 81657 970-479-2250 INSPECTION REPORT delL1-1. o / 6 .4 o 6'- 0)7 6 D A T E: 2 l °' PERMIT# : ©S _00/6 e0� _ 0/-6°7 BUILDING NAME: %e- ' ' -- ADDRESS: CONTACT NAME: 6 f COMPANY NAME: J 'i TYPE INSPECTION FIRE SPRINKLER ROUGH-IN FIRE ALARM ROUGH-IN HYDRO TEST FIRE ALARM FINAL FINAL / TCO CO OTHER AREA /SECTION INSPECTED / 4'/,, 6 :° �/6/�,' k-' d j s�`- /T. ./� j " /1— ,j,,,,, /4-- — fir.-zr'-. `,,, :,-,,V „,..2.0, -)..7;" �.., c.o .!`/�, .... ,5', " �= ✓ f .,sue �' j NOTES: INSPECTOR:. - �` '��4-- , TITLE ,27 Cl'''' TOWN OF VAIL - Vail Fire &Emergency Services 42 West Meadow Drive Vail, Colorado 81657 970-479-2250 INSPECTION REPORT DATE: �/L/ PERMIT# : X—C — 0'/" ' BUILDING NAME: >`'A--''fie ADDRESS: CONTACT NAME: 7#7 COMPANY NAME: `r TYPE INSPECTION FIRE SPRINKLER ROUGH-IN /FIRE ALARM ROUGH-IN HYDRO TEST IRE ALARM FINAL FINAL TCO CO OTHER AREA /SECTION INSPECTED NOTES: INSPECTOR: , TITLE -47/ :h.,aftat TOWN OF VAIL Vail Fire & Emergency Services 42 West Meadow Drive Vail Colorado 81657 970-479-2250 INSPECTION REPORT DATE: '74-7- 27 v PERMIT 8 : °ro,z_ BUILDING NAME: //X- '` '`' `" = ADDRESS: CONTACT NAME: (--ASe"eA� COMPANY NAME: TYPE INSPECTION FIRE SPRINKLER ROUGH-IN FIRE ALARM ROUGH-IN HYDRO TEST /IRE ALARM FINAL FINAL TCO CO OTHER AREA /SECTION INSPECTED NOTES: INSPECTOR: �"" .�.�— - -- , TITLE . '`" (-1:11(>/f ik, _AP TOWN OF VAIL - Vail Fire&Emergency Services 42 West Meadow Drive Vail, Colorado 81657 970-479-2250 INSPECTION REPORT DATE: /Z .�--/ PERMIT# : ,,` BUILDING NAME: /,'; �''� ADDRESS: ,--'' CONTACT NAME: ,.! ',%' -- `� COMPANY NAME: / � �'� i TYPE INSPECTION FIRE SPRINKLER ROUGH-IN FIRE ALARM ROUGH-IN 111YDRO TEST /FIRE ALARM FINAL FINAL / TCO CO OTHER AREA /SECTION INSPECTED ,/ NOTES: ` //�� '�--rte TITLE -O- 7�'r - INSPECTOR: �� /y TOWN OF IL VA Vail Fire & Emergency Services 42 West Meadow Drive Vail, Colorado 81657 970-479-2250 INSPECTION REPORT /L-----0‘ ao277 /= ©(' `-1`73e/ D A T E: Z Z:-/ PERMIT# : ` L. 6r / _-c6 do/vim BUILDING NAME: - ,"4e--' �-' ADDRESS: CONTACT NAME: —",=T7--- 67:-' 1' '' COMPANY NAME: X:7. - ` A TYPE INSPECTION FIRE SPRINKLER ROUGH-IN FIRE ALARM ROUGH-IN HYDRO TEST FIRE ALARM FINAL ✓� FINAL / TCO CO OTHER AREA /SECTION INSPECTED "7 V NOTES: INSPECTOR:.�%' ���`��"--- , TITLE .7 � '"" ,...„-J_ , ,,,,,, TOWN OF VAIL - Vail Fire&Emergency Services 42 West Meadow Drive Vail, Colorado 81657 970-479-2250 INSPECTION REPORT DATE: /2-. 2/ L? 7 PERMIT#1 : 427 0r/7/ BUILDING NAME: /y/':2 ADDRESS: CONTACT NAME: 72 / e /.4 --� COMPANY NAME: C TYPE INSPECTION FIRE SPRINKLER ROUGH-IN _ FIRE ALARM ROUGH-IN / HYDRO TEST / FIRE ALARM FINAL FINAL _ ,' TCO CO OTHER AREA /SECTION INSPECTED /j1 /2‘"/Czt/ ;17 / .5 7 NOTES: INSPECTOR: , TITLE _ 1 1 • no,eicy. Cf Mountain December 19, 2007 Terry Fleming B&B Electric 740 23 2/10 Road Grand Junction, CO 81505 Terry, —1-11 is letter is to confirm that we nit perform a 4 hour load bank test on the generator located at The AraBelle at Vail Square on 12-27-07. There will be a charge of$1,500.00 • F to perform this test. We had a teci-mician on site to perform this test on 12-6-07, however due,to the ncorrect 7r-11-nary re D-LI later-beLng L1E:tailed, this test cc aid not be completed at this time. Regards, //172 Melissa Guillen Power Gen Sales 51 1 Cummins Rocky Mountain WC 731 Scarlet Drive Grand Junction,CO 81505 Phone 970 242 5776 Fax 970 243 5494 Toll Free 800 564 6401 PRELIMINARY TEST & BALANCE REPORT ARRABELLE @ VAIL SQUARE VAIL, COLORADO BTC SERVICES 3025 SOUTH 3600 WEST WEST VALLEY CITY, UTAH 84119 PH (801)974-5911 FAX (801)974-5913 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG2-04 TECH: AREA: WAREHOUSE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1120 MODEL HBC TOTAL DESIGN CFM 1500 ESP 0.6 0.51 "RISE TOTAL OUTLET CFM 1875 MOTOR DATA MOTOR BALDOR HP 1/2 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/230 SF 1.25 NAMEPLATE AMPS 8.4/4.2 FRAME 56 ACTUAL VOLTS 120 ACTUAL AMPS 8.2 DRIVE DATA DRIVER 1VL40 SHEAVE x BORE 5/8 DRIVEN AK 54 SHEAVE x BORE 3/4 BELTS A 25 SIZE x QUANTITY 1 IN r OUT IFAN -0.39 "S.P. I 0.12 "S.P. I 0.51 I"RISE REMARKS: Page 1 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-01 TECH: KC AREA: LOCKERS FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200051645 TOTAL DESIGN CFM 1000 1080 ESP 0.06 0.55 "RISE TOTAL OUTLET CFM 1000 1080 MOTOR DATA MOTOR BALDOR HP 1/2 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/230 SF 1.25 NAMEPLATE AMPS 8.4/4.2 FRAME 56 ACTUAL VOLTS 120 ACTUAL AMPS 8.2 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK 54 SHEAVE x BORE 3/4 BELTS A 25 SIZE x QUANTITY 1 IN r OUT IFAN -0.35 "S.P. I 0.2 "S.P. I 0.551"RISE I REMARKS: Page 2 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/15/07 SYSTEM: FCU AG1-01 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G129.18 1-1 8" 1.00 250 250 290 116% 275 275 110% G116.01 1-2 8" 1.00 250 250 290 116% 275 275 110% G120.02 1-3 8" 1.00 250 250 280 112% 270 270 108% G118.02 1-4 8" 1.00 250 250 270 108% 260 260 104% REMARKS: Page 3 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-01 TECH: AREA: HOUSEKEEPING FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200051645 TOTAL DESIGN CFM 1000 898 ESP 0.06 0.22 "RISE TOTAL OUTLET CFM 900 898 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1-4.3 FRAME 56 ACTUAL VOLTS 118 ACTUAL AMPS 6.5 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE DRIVEN AK54 SHEAVE x BORE BELTS A 25 SIZE x QUANTITY IN r OUT FAN -0.37 "S.P. I -0.15 "S.P. I 0.22I'RISE REMARKS: Page 4 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU AG1-02 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING _ PLAN SITE AK CFM FPM FPM % FPM CFM 2-1 8" 9X9" 0.56 150 268 0 0% 265 148 99% G114.01 2-2 8" 8" 1.00 150 150 185 123% 145 145 97% G114.02 2-3 10" 10" 1.00 300 300 375 125% 300 300 100% G114.02 2-4 10" 10" 1.00 300 300 230 77% 305 305 102% REMARKS: NOTE: SMOKE DAMPER IS NOT OPEN Page 5 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-04 TECH: KC AREA: BUILDING MANAGER FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A 1120 MODEL HBC1200051645 TOTAL DESIGN CFM 1000 1070 ESP 0.6 0.51 "RISE TOTAL OUTLET CFM 1000 1070 MOTOR DATA MOTOR BALDOR HP 1/2 NAMEPLATE SPEED 1725 PHASE 11 NAMEPLATE VOLTS 115/230 SF 1.25 NAMEPLATE AMPS 8.4/4.2 FRAME 56 ACTUAL VOLTS 120 ACTUAL AMPS 8.2 DRIVE DATA DRIVER 1VL40 SHEAVE x BORE 5/8 DRIVEN AK 54 SHEAVE x BORE 3/4 BELTS A 25 SIZE x QUANTITY 1 IN [ OUT IFAN -0.39 "S.P. I 0.12 "S.P. I 0.51I"RISE I REMARKS: Page 6 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU AG1-04 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G114.05 4-1 6" 6" 1.00 100 100 125 125% 105 105 105% G114.06 4-2 10" 10" 1.00 275 275 385 140% 300 300 109% G114.06 4-3 10" 10" 1.00 275 275 375 136% 280 280 102% G114.04 4-4 6" 6" 1.00 100 100 125 125% 110 110 110% G114.03 4-5 6" 6" 1.00 100 100 135 135% 110 110 110% G114.07 4-6 8" 8" 1.00 150 150 170 113% 165 165 110% 1000 REMARKS: Page 7 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-05 TECH: KC AREA: LOCKERS FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200051646 TOTAL DESIGN CFM 1000 890 ESP 0.6 0.68 "RISE TOTAL OUTLET CFM 850 890 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1-4.3 FRAME 56.00 ACTUAL VOLTS 118 ACTUAL AMPS 7.3 DRIVE DATA DRIVER IVL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN OUT FAN -0.28 "S.P. 0.4 "S.P. I 0.681"RISE REMARKS: Page 8 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU AG1-05 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G106.03 5-1 8" 8" 1.00 250 250 270 108% 270 270 108% G106.03 5-2 8" 8" 1.00 250 250 300 120% 270 270 108% G102.13 5-3 8" 8" 1.00 350 350 340_ 97% 350 350 100% REMARKS: Page 9 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-06 TECH: AREA: STORAGE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC160005250 TOTAL DESIGN CFM 1500 1140 ESP 0.06 0.57 "RISE TOTAL OUTLET CFM 1150 1140 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.25 NAMEPLATE AMPS 3.4-3.4,1,7 FRAME 56 ACTUAL VOLTS 211,211,210 ACTUAL AMPS 2,2,2, DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK 64 SHEAVE x BORE 1 BELTS A28 SIZE x QUANTITY 1 IN r OUT FAN -0.35 "S.P. I 0.22 "S.P. I 0.57 "RISE I REMARKS: Page 10 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU AG1-06 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G106 6-1 8" 8" 1.00 250 250 0 0% 0 0 0% NOTE G107 6-2 8" 8" 1.00 100 100 52 52% 135 135 135% G102.09 6-3 8" 8" 1.00 150 150 45 30% 185 185 123% G102.10 6-4 8" 8" 1.00 100 100 60 60% 130 130 130% G102.11 6-5 8" 8" 1.00 100 100 30 30% 130 130 130% G102.02 6-6 8" 8" 1.00 150 150 30 20% 185 185 123% G102.02 6-7 8" 8" 1.00 150 150 30 20% 190 190 127% G102.02 6-8 8" 8" 1.00 150 150 0 0%, 185 185 123% REMARKS: NOTE:smoke damper is closed Page 11 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-07 TECH: KC AREA: MENS/WOMENS FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC1600052550 TOTAL DESIGN CFM 1500 1545 ESP 0.06 0.00 "RISE TOTAL OUTLET CFM 1440 1545 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.25 NAMEPLATE AMPS 3.3-3.0/1.5 FRAME 56.00 ACTUAL VOLTS 211, 211, 210 TYPE ACTUAL AMPS 2.4, 2.3, 2.3 SERIAL DRIVE DATA DRIVER IVL34 SHEAVE x BORE 5/8 DRIVEN AK64 SHEAVE x BORE 1 BELTS A25 SIZE x QUANTITY 1 IN r OUT IFAN "S.P. I "S.P. I 0.00 "RISE I REMARKS: Page 12 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU AG1-07 TECH: SIZE REQUIRED TEST 1 FINAL -G-102.12 ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % 7-1 8" 8" 1.00 120 120 580 483% 130 130 108% G106.05 7-2 8" 8" 1.00 120 120 160 133% 130 130 108% G106.04 7-3 8" 8" 1.00 180 180 65 36% 190 190 106% G106.04 7-4 8" 8" 1.00 180 180 580 322% 190 190 106% _G102.06 7-5 8" 8" 1.00 100 100 250 250% 105 105 105% G102.06 7-6 8" 8" 1.00 170 170 40 24% 185 185 109% G102.07 7-7 8" 8" 1.00 100 100 460 460% 105 105 105% _G102.07 7-8 8" 8" 1.00 170 170 445 262% 185 185 109% G102 7-9 8" 8" 1.00 300 300 50 17% 325 325 108% 1440 REMARKS: Page 13 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-10 TECH: KC AREA: CHILDERNS PROGRAM FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC1600052551 TOTAL DESIGN CFM 1500 1590 ESP 0.06 0.58 "RISE TOTAL OUTLET CFM 1500 1590 MOTOR DATA MOTOR GE HP 0.75 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208 SF 1.25 NAMEPLATE AMPS 3.6 FRAME 56.00 ACTUAL VOLTS 211 TYPE ACTUAL AMPS 2.1, 2.2, 2.2 SERIAL DRIVE DATA DRIVER IVL34 SHEAVE x BORE 5/8 DRIVEN AK64 SHEAVE x BORE 1 BELTS A25 SIZE x QUANTITY 1 IN _ OUT FAN -0.25 "S.P. _ 0.33 "S.P. 0.58 "RISE FILTER -0.1 "S.P. -0.15 "S.P. -0.05 "DROP COIL -0.15 "S.P. -0.25 "S.P. -0.10 "DROP REMARKS: UNIT IS MISSING DOOR Page 14 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU AG1-10 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING _PLAN SITE AK CFM FPM FPM % FPM CFM % G106.07 10-1 8" 8" 1.00 250 250 95 38% 265 265 106% G106.07 _ 10-2_ 8" 8" 1.00 250 250 95 38% 260 260 104% G106.07 10-3 8" 8" 1.00 250 250 80 32% 250 250 100% G106.07 10-4 8" 8" 1.00 250 250 90 36% 275 275 110% G106.07 10-5 8" 8" 1.00 250 250 85 34% 270 270 108% G106.07 10-6 8" 8" 1.00 250 250 75 30% 270 270 108% 1500 REMARKS: Page 15 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/9/2007 SYSTEM: FCU AG1-11 TECH: KC AREA: CHILDERNS PROGRAM FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC1600052550 TOTAL DESIGN CFM 1500 1570 ESP 0.06 0.54 "RISE TOTAL OUTLET CFM 1500 1570 MOTOR DATA MOTOR GE HP 0.75 NAMEPLATE SPEED 1725 PHASE 2, NAMEPLATE VOLTS 208-230/460 SF 1.25 NAMEPLATE AMPS 3.3-3.0/1.5 FRAME 56.00 ACTUAL VOLTS 211, 212, 210 TYPE ACTUAL AMPS 2.3, 2.0, 2.0 SERIAL DRIVE DATA DRIVER IVL34 SHEAVE x BORE 5/8 DRIVEN AK64 SHEAVE x BORE 1 BELTS A24 SIZE x QUANTITY 1 IN OUT FAN -0.24 "S.P. 0.3 "S.P. 0.54 "RISE -0.06 "S.P. 0 "S.P. 0.06 "DROP 0 "S.P. -0.24 "S.P. -0.24 "DROP REMARKS: Page 16 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/09/07 SYSTEM: FCU AG1-11 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G106 11-1 8" 8" 1.00 250 250 570 228% 245 245 98% G106 11-2 8" 8" 1.00 250 250 70 28% 270 270 108% G106 11-3 8" 8" 1.00 250 250 465 186% 270 270 108% G106 11-4 8" 8" 1.00 250 250 55 22% 265 265 106% G106 11-5 8" 8" 1.00 250 250 440 176% 260_ 260 104% G106 11-6 8" 8" 1.00 250 250 75 30% 260 260 104% 1500 REMARKS: Page 17 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-13 TECH: KC AREA: STORAGE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC2000051648 TOTAL DESIGN CFM 2000 2100 ESP 0.06 0.60 "RISE TOTAL OUTLET CFM 2000 2100 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.15 NAMEPLATE AMPS 14.4/7.2-7.2 FRAME 56Z ACTUAL VOLTS 211 TYPE ACTUAL AMPS 6.3 SERIAL DRIVE DATA DRIVER 1VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 1 BELTS A28 SIZE x QUANTITY 1 IN r OUT IFAN -0.49 "S.P. I 0.11 "S.P. I 0.60 "RISE REMARKS: Page 18 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/21/07 SYSTEM: FCU AG1-13 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G101 13-1 18/6 10" 1.00 375 375 75 20% 385 385 103% G101 13-2 18/6 10" 1.00 375 375 40 11% 395 395 105% G101 13-3 18/6 10" 1.00 375 375 650 173% 395 395 105% G101 13-4 18/6 10" 1.00 375 375 545 145% 380 380 101% G104.04 13-5 24/6 12" 1.00 500 500 150 30% 545 545 109% REMARKS: Page 19 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU AG1-14 TECH: KC AREA: STORAGE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A 1150 MODEL HBC1200051646 TOTAL DESIGN CFM 1000 1060 ESP 0.06 0.66 "RISE TOTAL OUTLET CFM 1000 1060 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1-4.3 FRAME 56.00 ACTUAL VOLTS 118 ACTUAL AMPS 6.9 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A 25 SIZE x QUANTITY 1 IN OUT IFAN -0.56 "S.P. 0.1 "S.P. I 0.661"RISE REMARKS: Page 20 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU AG1-14 TECH: kc SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G102.05 _ 14-1 18/6 8" 1.00 250 250 330 132% 255 255 102% G102.05 14-2 18/6 8" 1.00 250 250 315 126% 270 270 108% G102.05 14-3 18/6 8" 1.00 250 250 270 108% 275 275 110% G102.05 14-4 18/6 8" 1.00 250 250 185 74% 260 260 104% REMARKS: Page 21 ETC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-03 TECH: KC AREA: MANAGER FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HPY0800057529 TOTAL DESIGN CFM 500 510 ESP 0.5 0.46 "RISE TOTAL OUTLET CFM 500 510 MOTOR DATA MOTOR NO ACCESS HP NAMEPLATE SPEED N/A PHASE 1 NAMEPLATE VOLTS N/A SF 1.00 NAMEPLATE AMPS N/A ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE IN r OUT IFAN -0.24 "S.P. I 0.22 "S.P. I 0.461"RISE I REMARKS: Page 22 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-BG1-03 TECH: SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G129.01 03-1 8" 8" 1.00 250 250 345 138% 260 260 104% G129.02 03-2 8" 8" 1.00 250 250 315 126% 250 250 100% REMARKS: Page 23 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-04 TECH: KC AREA: RECEPTION FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200051645 TOTAL DESIGN CFM 1000 1055 ESP 0.6 0.54 "RISE TOTAL OUTLET CFM 1000 1055 MOTOR DATA MOTOR BALDOR HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/230 SF 1.25 NAMEPLATE AMPS 8.4/4.2 FRAME 56 ACTUAL VOLTS 119 ACTUAL AMPS 6.5 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN r OUT IFAN -0.32 "S.P. 0.22 "S.P. I 0.54 "RISE REMARKS: Page 24 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-BG1-04 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM _OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G128 04-1 8" 8" 1.00 250 250 280 112% 260 260 104% G128 04-2 8" 8" 1.00 250 250 250 100% 255 255 102% G125 04-3 8" 8" 1.00 250 250 250 100% 270 270 108% G125 04-3 8" 8" 1.00 250 250 340 136% 270 270 108% REMARKS: Page 25 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-05 TECH: AREA: CONFERENCE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 3 SPEED LOW MODEL HPY0800057529 TOTAL DESIGN CFM 250 275 ESP 0.5 0.67 "RISE TOTAL OUTLET CFM 250 275 MOTOR DATA MOTOR NO ACCESS HP NAMEPLATE SPEED N/A PHASE 1 NAMEPLATE VOLTS N/A SF 1.00 NAMEPLATE AMPS N/A ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE IN OUT IFAN -0.35 "S.P. 0.32 "S.P. I 0.671"RISE REMARKS: Page 26 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU-BG1-05 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G129.04 05-1 10" 10" 1.00 250 250 550 220% 275 275 110% REMARKS: Page 27 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-06 TECH: KC AREA: OFFICE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200056593 TOTAL DESIGN CFM 1000 1050 ESP 0.06 0.51 "RISE TOTAL OUTLET CFM 1000 1050 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 120/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1,4.3 FRAME 56 ACTUAL VOLTS 119 ACTUAL AMPS 6.6 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN r OUT IFAN -0.36 "S.P. I 0.15 "S.P. I 0.51 "RISE I REMARKS: Page 28 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-BG1-06 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G129.03 _ 06-1 _ 10" 10" 1.00 300 300 280 93% 310 310 103% G129.05 06-2 8" 8" 1.00 200 200 270 135% 205 205 103% G129.07 06-3 8" 8" 1.00 200 200 240 120% 215 215 108% G129.17 06-4 10" 10" 1.00 300 300 310 103% 320 320 107% REMARKS: Page 29 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-07 TECH: KC AREA: OFFICE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200056594 TOTAL DESIGN CFM 1000 1050 ESP 0.6 0.62 "RISE TOTAL OUTLET CFM 990 1050 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 120/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1,4.3 FRAME 56.00 ACTUAL VOLTS 119 TYPE ACTUAL AMPS 6.6 SERIAL DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN r OUT FAN -0.50 "S.P. 0.12 "S.P. I 0.621"RISE REMARKS: Page 30 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU-BG1-07 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G129-09 07-1 8" 8" 1.00 230 230 235 102% 235 235 102% G129-11 07-2 8" 8" 1.00 230 230 265 115% 250 250 109% G129-17 07-3 10" 10" 1.00 300 300 150 50% 330 330 110% G129-13 07-4 8" 8" 1.00 230 230 230 100% 240 240 104% REMARKS: Page 31 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-08 TECH: AREA: OFFICE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A 1120 MODEL HBC1200056594 TOTAL DESIGN CFM 1000 995 ESP 0.6 0.48 "RISE TOTAL OUTLET CFM 1000 995 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.25 NAMEPLATE AMPS 9.4/4.6-4.7 FRAME 56.00 ACTUAL VOLTS 120 ACTUAL AMPS 6.8 DRIVE DATA DRIVER IVL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN OUT FAN -0.28 "S.P. 0.2 "S.P. I 0.481"RISE REMARKS: Page 32 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/15/07 SYSTEM: FCU-BG1-08 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G126-03 08-1 8" 8" 1.00 300 300 215 72% 310 310 103% G129.08 08-2 8" 8" 1.00 300 300 225 75% 310 310 103% G123 08-3 8" 8" 1.00 200 200 290 145% 220 220 110% G123 08-4 8" 8" 1.00 200 200 280 140% 220 220 110% REMARKS: Page 33 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-09 TECH: AREA: OFFICE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM MODEL HBC1200056593 TOTAL DESIGN CFM 1000 1065 ESP 0.06 0.55 "RISE TOTAL OUTLET CFM 1000 1065 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 120/208-230 SF 1.25 NAMEPLATE AMPS 8.6/4.1,4.3 FRAME 56.00 ACTUAL VOLTS 119 TYPE ACTUAL AMPS 7.5 SERIAL DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN [ OUT IFAN -0.34 "S.P. I 0.21 "S.P. I 0.551"RISE REMARKS: Page 34 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/15/07 SYSTEM: FCU-BG1-09 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM _ OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G129.10 09-1 8" 8" 1.00 200 200 277 139% 220 220 110% G129.12 09-2 8" 8" 1.00 200 200 0 0% 210 210 105% G129.14 09-3 8" 8" 1.00 200 200 337 169% 210 210 105% G129.03 09-4 8" 8" 1.00 200 200 266 133% 210 210 105% G129.03 09-5 8" 8" 1.00 200 200 326 163% 215 215 108% REMARKS: Page 35 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-10 TECH: AREA: OFFICE FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 3 SPEED LOW MODEL HPY0800057529 TOTAL DESIGN CFM 500 525 ESP 0.5 0.30 "RISE TOTAL OUTLET CFM 500 525 MOTOR DATA MOTOR NO ACCESS HP N/A NAMEPLATE SPEED N/A PHASE N/A NAMEPLATE VOLTS N/A SF N/A NAMEPLATE AMPS N/A FRAME N/A ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE IN OUT [FAN -0.15 "S.P. 0.15 "S.P. I 0.30 "RISE REMARKS: Page 36 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU-BG1-10 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G129.15 10-1 8" 8" 1.00 250 250 330 132% 270 270 108% G129.15 10-2 8" 8" 1.00 250 250 320 128% 255 255 102% REMARKS: NOTE;LOW SPEED Page 37 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU BG1-13 TECH: KC AREA: ELEV CTRL RM FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 3 SPEED LOW MODEL HPY0800057529 TOTAL DESIGN CFM 500 650 ESP 0.5 0.25 TOTAL OUTLET CFM 500 650 MOTOR DATA MOTOR NO ACCESS HP N/A NAMEPLATE SPEED N/A PHASE N/A NAMEPLATE VOLTS N/A SF N/A NAMEPLATE AMPS N/A FRAME N/A ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE IN r OUT FAN -0.15 "S.P. I 0.1 "S.P. I 0.251"RISE REMARKS: Page 38 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/14/07 SYSTEM: FCU-BG1-13 TECH: KC SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G130 1 10/12 11"X 9" 0.68 500 735 1390 189% 950 646 129% REMARKS: Page 39 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU A1-06 TECH: KC AREA: RETAIL FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 890 MODEL HBC2000051647 TOTAL DESIGN CFM 2000 1995 ESP 0.6 0.51 TOTAL OUTLET CFM 2000 1995 MOTOR DATA MOTOR BALDOR HP 1 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/230 SF 1.15 NAMEPLATE AMPS 13.4/6.7 FRAME 56.00 ACTUAL VOLTS 205 ACTUAL AMPS 5.1 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK66 SHEAVE x BORE 1 BELTS A29 SIZE x QUANTITY 1 IN r OUT FAN -0.32 "S.P. I 0.19 "S.P. I 0.51 I"RISE REMARKS: Page 40 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/06/07 SYSTEM: FCU-A1-06 TECH: KC SIZE _ REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM P119 06-1 10" 1.00 400 400 385 96% 400 400 100% P119 06-2 10" 1.00 400 400 595 149% 400 400 100% P119 06-3 10" 1.00 400 400 685 171% 390 390 98% P119 06-4 10" 1.00 400 400 625 156% 405 405 101% P117 06-5 8" 1.00 200 200 285 143% 205 205 103% P118 06-6 8" 1.00 200 200 320 160% 195 195 98% 2000 REMARKS: Page 41 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU A1-07 TECH: KC AREA: KIDS SKISCHOOL REG. FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC2000051648 TOTAL DESIGN CFM 2000 1825 ESP 0.06 0.60 TOTAL OUTLET CFM 2000 1825 MOTOR DATA MOTOR GE HP 1 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.15 NAMEPLATE AMPS 14.4/7.2-7.2 FRAME 56Z ACTUAL VOLTS 205 ACTUAL AMPS 7.0 DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 1 BELTS A28 SIZE x QUANTITY 1 IN r OUT IFAN -0.45 "S.P. I 0.15 "S.P. j 0.601"RISE REMARKS: Page 42 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/06/07 SYSTEM: FCU-A-07 TECH: KC SIZE _ REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM P103.01 07-1 4'12S 4'/2S 1.00 1000 1000 645 65% 900 900 90% P103.01 07-2 4'/2S 4'/2S 1.00 1000 1000 950 95% 925 925 93% REMARKS: Page 43 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU A1-09 TECH: KC AREA: FLOOR 1 FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC1200051646 TOTAL DESIGN CFM 1000 980 ESP 0.6 0.60 TOTAL OUTLET CFM 1000 980 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.15 NAMEPLATE AMPS 8.6/4.1-4.3 FRAME 56 ACTUAL VOLTS 120 TYPE ACTUAL AMPS 7.0 SERIAL DRIVE DATA DRIVER 1VP34 SHEAVE x BORE 1/2 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN r OUT FAN -0.54 "S.P. I 0.06 "S.P. I 0.601"RISE REMARKS: Page 44 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/06/07 SYSTEM: FCU-A1-09 TECH: KC SIZE _ REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % P103.04 09-1 10" 10" 1.00 300 300 290 97% 300 300 100% P103.05 09-2 10" 10" 1.00 300 300 330 110% 310 310 103% P119 09-3 10" 10" 1.00 400 400 360 90% 370 370 93% REMARKS: Page 45 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU Al-10 TECH: KC AREA: RETAIL FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1725 MODEL HBC1200051646 TOTAL DESIGN CFM 1000 905 ESP 0.06 1.06 TOTAL OUTLET CFM 1000 905 MOTOR DATA MOTOR GE HP 0.5 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115/208-230 SF 1.15 NAMEPLATE AMPS 8.6/4.1-4.3 FRAME 56 ACTUAL VOLTS 118 TYPE ACTUAL AMPS 7.8 SERIAL DRIVE DATA DRIVER 1 VL40 SHEAVE x BORE 5/8 DRIVEN AK54 SHEAVE x BORE 3/4 BELTS A25 SIZE x QUANTITY 1 IN r OUT (FAN -0.32 "S.P. 0.74 "S.P. I 1.061"RISE REMARKS: Page 46 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-B4-01 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 3 speed LOW MODEL HPY0600057520 TOTAL DESIGN CFM 400 530 SERIAL NUM 961457-60-4 ESP 0.27 0.18 MOTOR DATA MOTOR NO ACSSES HP N/A NAMEPLATE SPEED NO ACSSES PHASE 1 NAMEPLATE VOLTS NO ACSSES SF 1 NAMEPLATE AMPS NO ACSSES ACTUAL VOLTS 120 ACTUAL AMPS 1.7 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 335 168% 270 270 135% 2 8/6 1.00 200 200 290 145% 260 260 130% Page 93 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-B4-03 TECH: FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL RPY06115 TOTAL DESIGN CFM 400 405 SERIAL NUM 961458-220-1 ESP 0.27 0.22 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 119 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM olo FPM CFM % 1 10/10 1.00 400 400 625 156% 405 405 101% Page 94 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-B4-04 TECH: FAN DATA DESIGN ACTUAL MAKE FAN RPM 3 speed LOW MODEL HPY0600057520 TOTAL DESIGN CFM 400 540 SERIAL NUM 961457-60-4 ESP 0.27 0.20 MOTOR DATA MOTOR NO ACSSES HP N/A NAMEPLATE SPEED NO ACSSES PHASE 1 NAMEPLATE VOLTS NO ACSSES SF 1 NAMEPLATE AMPS NO ACSSES ACTUAL VOLTS 120 ACTUAL AMPS 1.7 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 10/10 1.00 400 400 650 163% 540 540 135% Page 95 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/15/07 SYSTEM: FCU-B4-05 TECH: kc FAN DATA DESIGN ACTUAL MAKE FAN RPM 1075 HIGH MODEL MPY10115 TOTAL DESIGN CFM 800 905 SERIAL NUM 961454-110-2 ESP 0.27 0.25 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 2.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 250 250 230 92% 260 260 104% 2 8/6 1.00 150 150 285 190% 165 165 110% 3 10/10 1.00 300 300 300 100% 320 320 107% 4 8/6 1.00 150 150 195 130% 160 160 107% Page 96 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-B4-08 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1075 LOW MODEL MPY10115 TOTAL DESIGN CFM 800 820 SERIAL NUM 961458-100-3 ESP 0.27 0.19 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 120 ACTUAL AMPS 2.5 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 385 96% 410 410 103% 2 8/6 1.00 100 100 230 230% 110 110 110% 3 8/6 1.00 100 100 245 245% 110 110 110% 4 8/6 1.00 200 200 235 118% 190 190 95% Page 97 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-01 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 405 SERIAL 961452-240-2 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 117 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 520 130% 405 405 101% Page 98 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-02 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RMY06115 TOTAL DESIGN CFM 400 395 SERIAL 961452-180-2 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 395 99% 395 395 99% Page 99 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-03 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RPY06115 TOTAL DESIGN CFM 400 415 SERIAL 961452-150-1 ESP 0.27 020 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 415 104% 415 415 104% Page 100 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-04 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RPY06115 TOTAL DESIGN CFM 400 420 SERIAL 961452-160-2 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 420 105% 420 420 105% Page 101 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-05 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A MED MODEL RPY06115 TOTAL DESIGN CFM 400 430 SERIAL 961452-150-2 ESP 0.27 0.21 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 480 120% 430 430 108% Page 102 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-06 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MSY06115 TOTAL DESIGN CFM 400 360 SERIAL 961452-150-1 ESP 0.27 0.19 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 360 90% 360 360 90% Page 103 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-08 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RPY06115 TOTAL DESIGN CFM 400 405 SERIAL 961452-160-C ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS L3 ACTUAL VOLTS 121 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 560 140% 405 405 101% Page 104 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10-09-07 SYSTEM: FCU-C2-09 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 410 SERIAL 961452-250-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 118 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 410 103% 410 410 103% Page 105 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/09/07 SYSTEM: FCU-C2-10 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MSY10115 TOTAL DESIGN CFM 800 850 SERIAL 961452-130-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 118 ACTUAL AMPS 2.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/6 1.00 300 300 345 115% 310 310 103% 2 12/6 1.00 300 300 460 153% 330 330 110% 3 8/6 1.00 200 200 250 125% 210 210 105% Page 106 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/09/07 SYSTEM: FCU-C2-11 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MSY10115 TOTAL DESIGN CFM 800 910 SERIAL 961452-100-1 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 115 ACTUAL AMPS 3.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/6 1.00 275 275 410 149% 300 300 109% 2 12/6 1.00 275 275 475 173% 320 320 116% 3 6/6 1.00 100 100 25 25% 110 110 110% 4 8/6 1.00 150 150 250 167% 180 180 120% Page 107 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/09/07 SYSTEM: FCU-C2-12 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A MED MODEL MPY10115 TOTAL DESIGN CFM 800 850 SERIAL 961452-70-2 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 122 ACTUAL AMPS 3.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 250 125% 220 220 110% 2 8/6 1.00 200 200 190 95% 220 220 110% 3 8/6 1.00 200 200 285 143% 200 200 100% 4 8/6 1.00 200 200 230 115% 210 210 105% Page 108 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/09/07 SYSTEM: FCU-C2-13 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A HIGH MODEL MPY06115 TOTAL DESIGN CFM 400 365 SERIAL 961452-20-2 ESP 0.27 0.30 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 121 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 365 91% 365 365 91% Page 109 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-01 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A HIGH MODEL RSY06115 TOTAL DESIGN CFM 400 370 SERIAL 961454-200-1 ESP 0.27 0.30 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 121 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 370 93% 370 370 93% Page 110 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-02 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY06115 TOTAL DESIGN CFM 400 405 SERIAL 961452-30-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 117 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 590 148% 405 405 101% Page 111 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-03 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RMY06115 TOTAL DESIGN CFM 400 430 SERIAL 961452-180-1 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 430 108% 430 430 108% Page 112 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-04 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A HIGH MODEL MPY10115 TOTAL DESIGN CFM 800 860 SERIAL 961452-70-1 ESP 0.27 0.25 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.38 ACTUAL VOLTS 119 ACTUAL AMPS 2.6 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 210 105% 215 215 108% 2 8/6 1.00 200 200 200 100% 220 220 110% 3 8/6 1.00 200 200 250 125% 215 215 108% 4 8/6 1.00 200 200 225 113% 210 210_ 105% Page 113 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-05 TECH: JD FAN DATA DESIGN ACTUAL MAKE !EC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 460 SERIAL 961452-240-3 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 770 193% 460 460 115% Page 114 BIC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-06 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY06115 TOTAL DESIGN CFM 400 420 SERIAL 961452-10-1 ESP 0.27 0.19 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 121 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 420 105% 420 420 105% Page 115 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/01/07 SYSTEM: FCU-C3-07 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A MED MODEL MPY06115 TOTAL DESIGN CFM 400 450 SERIAL 961452-10-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 118 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM 1 12/12 1.00 400 400 530 133% 450 450 113% Page 116 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/05/07 SYSTEM: FCU-C8-08 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A MED MODEL MPY06115 TOTAL DESIGN CFM 400 440 SERIAL 961452-30-2 ESP 0.27 0.21 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 119 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 550 138% 440 440 110% Page 117 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C3-09 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY10115 TOTAL DESIGN CFM 800 965 SERIAL 96145-270-3 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 120 ACTUAL AMPS 3.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 270 135% 250 250 125% 2 8/6 1.00 200 200 255 128% 250 250 125% 3 8/6 1.00 200 200 235 118% 235 235 118% 4 8/6 1.00 200 200 230 115% 230 230 115% Page 118 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/04/07 SYSTEM: FCU-C3-10 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RPY06115 TOTAL DESIGN CFM 400 400 SERIAL 961452-160-3 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 560 140% 400 400 100% Page 119 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/05/07 SYSTEM: FCU-C3-11 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 390 SERIAL 961452-730-1 ESP 0.27 0.22 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 121 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 390 98% 390 390 98% Page 120 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/05/07 SYSTEM: FCU-C3-12 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RMY06115 TOTAL DESIGN CFM 400 365 SERIAL 961452-200-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 119 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 365 91% 365 365 91% Page 121 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08-07 SYSTEM: FCU-C3-13 TECH: JD FAN DATA DESIGN ACTUAL MAKE !EC FAN RPM N/A LOW MODEL RMY06115 TOTAL DESIGN CFM 400 400 SERIAL 961452-190-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 121 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 400 100% 400 400 100% Page 122 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-14 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 410 SERIAL 961452-220-1 ESP 0.27 0.21 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 410 103% 410 410 103% Page 123 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-15 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 405 SERIAL 961452-210-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 620 155% 405 405 101% Page 124 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-16 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL RSY06115 TOTAL DESIGN CFM 400 440 SERIAL 961452-260-1 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 460, 115% 440 440 110% Page 125 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-17 TECH: JD FAN DATA DESIGN ACTUAL MAKE !EC FAN RPM N/A LOW MODEL RPY06115 TOTAL DESIGN CFM 400 410 SERIAL 961452-160-1 ESP 0.27 0.19 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 122 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 410 103% 410 410 103% Page 126 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-18 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY10115 TOTAL DESIGN CFM 800 820 SERIAL 961452-60-1 ESP 0.27 0.19 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 120 ACTUAL AMPS 3.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 300 300 385 128% 315 315 105% 2 8/6 1.00 300 300 385 128% 310 310 103% 3 8/6 1.00 200 200 220 110% 195 195 98% Page 127 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/08/07 SYSTEM: FCU-C3-19 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY10115 TOTAL DESIGN CFM 800 860 SERIAL 961452-50-1 ESP 0.27 0.18 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 3 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/6 1.00 275 275 290 105% 295 295 107% 2 12/6 1.00 275 275 285 104% 290 290 105% 3 6/6 1.00 100 100 135 135% 110 110 110% 4 8/6 1.00 150 150 200 133% 165 165 110% Page 128 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 09/04/07 SYSTEM: FCU-C3-20 TECH: JD FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM N/A LOW MODEL MPY06115 TOTAL DESIGN CFM 400 380 SERIAL 961452-20-1 ESP 0.27 0.21 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 380 95%, 380 380 95% Page 129 BTC SERVICES DIRECT DRIVE FAN TEST REPORT NO POWER PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C3-21 TECH: FAN DATA DESIGN ACTUAL MAKE FAN RPM MODEL TOTAL DESIGN CFM 2500 SERIAL NUMBER ESP 0.27 MOTOR DATA MOTOR HP NAMEPLATE SPEED PHASE NAMEPLATE VOLTS SF NAMEPLATE AMPS FRAME ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 14/6 350 #DIV/0! #DIV/0! 0 0% 2 14/6 350 #DIV/0! #DIV/0! 0 0% 3 14/6 350 #DIV/0! #DIV/0! 0 0% 4 14/6 350 #DIV/0! #DIV/0! 0 0% 5 14/6 350 #DIV/0! #DIV/0! 0 0% 6 14/6 350 #DIV/0! #DIV/0! 0 0% 7 14/6 350 #DIV/0! #DIV/0! 0 0% Page 130 BTC SERVICES DIRECT DRIVE FAN TEST REPORT NO POWER PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-C3-22 TECH: FAN DATA DESIGN ACTUAL MAKE FAN RPM MODEL TOTAL DESIGN CFM 800 SERIAL NUMBER ESP 0.27 MOTOR DATA MOTOR HP NAMEPLATE SPEED PHASE NAMEPLATE VOLTS SF NAMEPLATE AMPS FRAME ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 150 #DIV/0! #DIV/0! 0 0% 2 8/6 150 #DIV/0! #DIV/0! 0 0% 3 8/6 150 #DIV/0! #DIV/0! 0 0% 4 8/6 150 #DIV/0! #DIV/0! 0 0% 5 8/6 100 #DIV/0! #DIV/0! 0 0% 6 8/6 100 #DIV/0! #DIV/0! 0 0% Page 131 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/15/07 SYSTEM: FCU-C4-01 TECH: kc FAN DATA DESIGN ACTUAL MAKE FAN RPM 1040 MED MODEL MPY16115 TOTAL DESIGN CFM 400 440 SERIAL 961453-10-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM 1 12/12 1.00 400 400 485 121% 440 440 110% Page 132 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C4-04 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1075 MED MODEL IPY10115 TOTAL DESIGN CFM 800 845 SERIAL 961453-80-1 ESP 0.27 0.22 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 2.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 470 118% 440 440 110% 2 8/6 1.00 200 200 280 140% 185 190 95% 3 8/6 1.00 200 200 235 118% 220 220 110% Page 133 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C4-05 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL RPY06115 TOTAL DESIGN CFM 400 425 SERIAL NUMBER ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 675 169% 425 425 106% Page 134 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C4-06 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL MPY06115 TOTAL DESIGN CFM 400 440 SERIAL 961453-10-3 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 119 ACTUAL AMPS 1.3 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 12/12 1.00 400 400 565 141% 440 440 110% Page 135 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-C4-07 TECH: FAN DATA DESIGN ACTUAL MAKE FAN RPM 1075 MED MODEL IPY10115 TOTAL DESIGN CFM 800 850 SERIAL 961453-80-2 ESP 0.27 0.25 MOTOR DATA MOTOR GE HP 01/05/07 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 2.2 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 260 130% 220 220 110% 2 8/6 1.00 200 200 215 108% 220 220 110% 3 8/6 1.00 200 200 200 100% 200 200 100% 4 8/6 1.00 200 200 230 115% 210 210 105% Page 136 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-C4-08 TECH: FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL MPY06115 TOTAL DESIGN CFM 400 455 SERIAL 961458-30-5 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 119 ACTUAL AMPS 1.3 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 200 200 120 60% 225 225 113% 2 8/6 1.00 200 200 335 168% 230 230 115% Page 137 STC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: FCU-C4-09 TECH: FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL RPY06115 TOTAL DESIGN CFM 400 405 SERIAL NUMBER 961453-250-3 ESP 0.27 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 FRAME ACTUAL VOLTS 119 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 615 154% 405 405 101% Page 138 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 1 8-Dec-07 SYSTEM: FCU-C4-11 TECH: kc FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1040 LOW MODEL RPY06115 TOTAL DESIGN CFM 400 410 SERIAL NUMBER 961453-230-1 ESP 0.27 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 FRAME ACTUAL VOLTS 119 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 620 155% 410 410 103% Page 139 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-C4-13 TECH: FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1075 LOW MODEL MSY10115 TOTAL DESIGN CFM 800 870 SERIAL NUMBER 961453-200-1 ESP 0.27 0.22 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF NAMEPLATE AMPS 3.3 ACTUAL VOLTS 120 ACTUAL AMPS 2.7 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 445 111% 415 415 104% 2 8/6 1.00 150 150 205 137% 170 170 113% 3 8/6 1.00 150 150 350 233% 170 170 113% 4 8/6 1.00 100 100 150 150% 115 115 115% Page 140 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C4-14 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM LOW MODEL RPY06115 TOTAL DESIGN CFM 400 440 SERIAL 961453-250-1 ESP 0.27 MOTOR DATA MOTOR GE HP 1/15 NAMEPLATE SPEED 1040 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 1.3 ACTUAL VOLTS 120 ACTUAL AMPS 1.1 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 400 400 610 153% 440 440 110% Page 141 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: FCU-C4-15 TECH: FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1075 LOW MODEL MPY10115 TOTAL DESIGN CFM 800 830 SERIAL 961453-110 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 2.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 300 300 355 118% 310 310 103% 2 10/10 1.00 300 300 445 148% 300 300 100% 3 8/6 1.00 200 200 305 153% 220 220 110% Page 142 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/07 SYSTEM: FCU-C4-16 TECH: KC FAN DATA DESIGN ACTUAL MAKE IEC FAN RPM 1075 LOW MODEL MPY10-115 TOTAL DESIGN CFM 800 905 SERIAL 961453-100-1 ESP 0.27 0.20 MOTOR DATA MOTOR GE HP 1/5 NAMEPLATE SPEED 1075 PHASE 1 NAMEPLATE VOLTS 115 SF 1 NAMEPLATE AMPS 3.3 ACTUAL VOLTS 119 ACTUAL AMPS 2.4 DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 10/10 1.00 275 275 460 167% 310 310 113% 2 10/10 1.00 275 275 475 173% 310 310 113% 3 8/6 1.00 100 100 210 210% 115 115 115% 4 8/6 1.00 150 150 245 163% 170 170 113% Page 143 BTC SERVICES DIRECT DRIVE FAN TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/20/07 SYSTEM: FCU-C4-19 TECH: KC FAN DATA DESIGN ACTUAL MAKE ECI FAN RPM 3 speed med MODEL HPY0800052661 TOTAL DESIGN CFM 800 915 SERIAL 961455-110-1 ESP 0.27 0.20 MOTOR DATA MOTOR NO ACCESS HP NAMEPLATE SPEED PHASE NAMEPLATE VOLTS SF NAMEPLATE AMPS FRAME ACTUAL VOLTS 120 TYPE ACTUAL AMPS 2 SERIAL DIRECT DRIVE SIZE REQUIRED TEST 1 FINAL OPENING PLAN AK CFM FPM FPM % FPM CFM % 1 8/6 1.00 100 100 175 175% 110 110 110% 2 8/6 1.00 100 100 185 185% 110 110 110% 3 8/6 1.00 100 100 155 155% 120 120 120% 4 8/6 1.00 100 100 145 145% 115 115 115% 5 8/6 1.00 100 100 80 80% 110 110 110% 6 8/6 1.00 100 100 140 140% 120 120 120% 7 8/6 1.00 100 100 130 130% 115 115 115% 8 8/6 1.00 100 100 100 100% 115 115 115% Page 144 BTC SERVICES AIR BALANCE DATA PROJECT: ARRABELLA DATE: 12-06-07 SYSTEM: STAIR 3 TECH: KC floor pressure BG 0.04 B1 0.04 B2 0.05 B3 0.05 B4 0.06 B5 0.06 B6 0.07 ROOF 0.07 REMARKS: Page 145 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-8 TECH: KC AREA: STAIR 3 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 985 MODEL 245QMXS TOTAL DESIGN CFM 10500 10094 SIZE ESP 0.5 0.45 "RISE JOB SERIAL NUMBER 1825904923-00/0012701 MOTOR DATA MOTOR A.O. SMITH HP 5 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 12.8/6.4 FRAME S184T ACTUAL VOLTS 210,211,210 TYPE MOGB ACTUAL AMPS 8.5,8.6,8.4 SERIAL STARTER DATA STARTER CUTLER HAM MODEL SIZE NEMA 1 CLASS THERMALS H2012B RATING 14 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP50 SHEAVE x BORE 1 1/8 DRIVEN 2TB94 SHEAVE x BORE 1 5/8 BELTS A70 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.29 "S.P. 0.16 "S.P. I 0.45 "RISE REMARKS: VELGRID: 118"X 24" = 19.6'SQ X 515 FPM= 10094 CFM Page 146 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: AHU-1 TECH: AREA: SPA FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM 1960 MODEL XTI-069X081- TOTAL DESIGN CFM 11000 12230 MODEL HALA046A ESP 3 0.00 "RISE O.S.A. CFM 11000 SERIAL NUMBER ACRMXT0171 TOTAL OUTLET CFM 11150 MOTOR DATA MOTOR BALDOR HP 15 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 41-38/19 FRAME 254T ACTUAL VOLTS 485,486,486 ACTUAL AMPS 12.8,13.2,12.9 STARTER DATA STARTER SQUARED MODEL SIZE CLASS THERMALS ADJUSTABLE 17-25 RATING SET TO 19 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP 75 SHEAVE x BORE 1 5/8 DRIVEN 2B 56 SHEAVE x BORE 2 3/16 BELTS AX 93 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER "S.P. "S.P. 0.00 "DROP HEAT COIL "S.P. "S.P. 0.00 "DROP COOL COIL "S.P. "S.P. 0.00 "DROP FAN "S.P. "S.P. 0.00 "RISE REMARKS: TEST 1 VELGRID COIL ,SIZE;55"X 69"= 26.3'SQ.X 546 FPM= 14360 CFM(2105RPM) TEST 2 VELGRID COIL ,SIZE;55"X 69"= 26.3'SQ.X 465 FPM= 12230 CFM(1960RPM) Page 147 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/20/2007 SYSTEM: AHU-2 TECH: kc AREA: BALLROOM FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM n/a 1800 MODEL XTI-078X078- TOTAL DESIGN CFM 15000 17409 MODEL JAMA046A ESP 3.5 3.29 "RISE O.S.A. CFM 15000 17409 SERIAL NUMBER ACRMXTO172 TOTAL OUTLET CFM 17335 16975 MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 485,486,487 ACTUAL AMPS 18.7,18.8,18.6 STARTER DATA STARTER YORK VFD MODEL SIZE CLASS THERMALS ELECTRONIC RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B 70 SK SHEAVE x BORE 1 5/8 DRIVEN 2B 70 SK SHEAVE x BORE 2 7/16 BELTS BX 108 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -0.44 "S.P. -0.62 "S.P. -0.18 "DROP HEAT COIL -0.62 "S.P. -0.83 "S.P. -0.21 "DROP COOL COIL -0.83 "S.P. -1.29 "S.P. -0.46 "DROP FAN -1.28 "S.P. 2.01 "S.P. 3.29 "RISE REMARKS: VELGRID COIL ,SIZE;65"X 62"= 27.9'SQ. X 624 FPM = 17409 CFM Page 148 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/20/07 SYSTEM: AHU-2 TECH: kc SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G146 TB-1-1 4'/2S 4'/2S 1.00 250 250 350 140% 255 255 102% G146 TB-1-2 4'/2S 4'/2S 1.00 250 250 350 140% 275 275 110% G146 TB-1-3 472S 4'/2S 1.00 250 250 360 144% 270 270 108% G146 TB-1-4 4'/2S 472S 1.00 250 250 400 160% 250 250 100% G146 TB-1-5 4'/2S 4'/2S 1.00 250 250 55 22% 255 255 102% G146 TB-1-6 472S 472S 1.00 250 250 50 20% 275 275 110% Address Duct dia Cooling Heating Min CAL Setpoints 45 0.78 1500 750 450 2.23 G145.03 TB-2-1 4'/2S 4'/2S 1.00 200 200 165 83% 195 195 98% G145.03 TB-2-2 4'/2S 4'/2S 1.00 200 200 155 78% 185 185 93% G145.03 TB-2-3 4'/2S 4'/2S 1.00 200 200 100 50% 190 190 95% G145.03 TB-2-4 4'/2S 4'/2S 1.00 200 200 90 45% 195 195 98% G145.03 TB-2-5 472S 4'/2S 1.00 200 200 190 95% 195 195 98% G145.03 TB-2-6 4'/2S 4'/2S 1.00 200 200 135 68% 195 195 98% Address Duct dia Cooling Heating Min CAL Setpoints 46 0.54 1200 600 360 2 G145.02 TB-3-1 4'/2S 4'/2S 1.00 185 185 30 16% 190 190 103% G145.02 TB-3-2 4'/2S 4'/2S 1.00 185 185 60 32% 190 190 103% G145.02 TB-3-3 472S 4'/2S 1.00 185 185 305 165% 175 175 95% G145.02 TB-3-4 472S 4'/2S 1.00 185 185 55 30% 185 185 100% G145.02 TB-3-5 4'/2S 4'/2S 1.00 185 185 230 124% 175 175 95% G145.02 TB-3-6 472S 4'/2S 1.00 185 185 295 159% 180 180 97% Address Duct dia Cooling Heating Min CAL Setpoints 47 0.54 1100 550 330 2 G145.01 TB-4-1 4'/2S 4'/2S 1.00 200 200 180 90% 195 195 98% G145.01 TB-4-2 4'/2S 472S 1.00 200 200 190 95% 195 195 98% 6145.01 TB-4-3 4'/2S 4'/2S 1.00 200 200 60 30% 205 205 103% G145.01 TB-4-4 4'/2S 4'/2S 1.00 200 200 150 75% 200 200 100% G145.01 TB-4-5 4'/2S 4'/2S 1.00 200 200 230 115% 190 190 95% G145.01 TB-4-6 4'/2S 472S 1.00 200 200 75 38% 200 200 100% Address Duct dia Cooling Heating Min CAL Setpoints 48 0.54 1200 600 360 2.2 G145 TB-5-1 4'/2S 4'/2S 1.00 250 250 245 98% 240 240 96% G145 TB-5-2 4'/2S 4'/2S 1.00 250 250 80 32% 245 245 98% G145 TB-5-3 4'/2S 4'/2S 1.00 - 250 250 275 110% 235 235 94% G145 TB-5-4 4'/2S 4'/2S 1.00 250 250 275 110% 235 235 94% G145 TB-5-5 4/2S 4'/2S 1.00 250 250 335 134% 240 240 96% G145 TB-5-6 4'/2S 4'/2S 1.00 250 250 80 32% 250 250 100% G145 TB-5-7 4'/2S 4'/2S 1.00 250 250 270 108% 250 250 100% G145 TB-5-8 4'/2S 4'/2S 1.00 250 250 80 32% 260 260 104% G145 TB-5-9 4'/2S 4'/2S 1.00 250 250 290 116% 235 235 94% G145 TB-5-10 472S 4'/2S 1.00 250 250 325 130% 250 250 100% Address Duct dia Cooling Heating Min CAL Setpoints 49 1.06 2500 1250 750 1.99 REMARKS: Page 149 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/20/07 SYSTEM: AHU-2 TECH: kc SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G148.01 TB-6-2 4'/2S 4'/2S 1.00 300 300 270 90% 270 270 90% G148.01 TB-6-3 4'/2S 4'/2S 1.00 300 300 300 100% 270 270 90% G148.01 TB-6-4 472S 4'/2S 1.00 300 300 345 115% 280 280 93% G148.01 TB-6-5 4'/2S 4'/2S 1.00 300 300 290 97% 270 270 90% G148.01 TB-6-6 4'/2S 4'/2S 1.00 300 300 295 98% 280 280 93% G148.01 TB-6-7 4'/2S 4'/2S 1.00 300 300 240 80% 290 290 97% G148.01 TB-6-8 4'/2S 4'/2S 1.00 300 300 175 58% 290 290 97% G148.01 TB-6-9 4'/2S 472S 1.00 300 300 325 108% 305 305 102% G148.01 TB-6-10 4'/2S 4'/2S 1.00 300 300 145 48% 285 285 95% G148.01 TB-6-11 4'/2S 4'/2S 1.00 300 300 290 97% 270 270 90% G148.01 TB-6-12 4'/2S 4'/2S 1.00 300 300 325 108% 275 275 92% Address Duct dia Cooling Heating Min CAL Setpoints 50 1.39 3600 1800 1080 1.61 G148.02 TB-7-1 4'/2S 4'/2S 1.00 300 300 120 40% 315 315 105% G148.02 TB-7-2 4'/2S 4'/2S 1.00 300 300 360 120% 280 280 93% G148.02 TB-7-3 4'/2S 4'/2S 1.00 300 300 450 150% 295 295 98% G148.02 TB-7-4 4'/2S 4'/2S 1.00 300 300 250 83% 280 280 93% G148.02 TB-7-5 4'/2S 4'/2S 1.00 300 300 360 120% 305 305 102% G148.02 18-7-6 4'/2S 4'/2S 1.00 300 300 305 102% 315 315 105% Address Duct dia Cooling Heating Min CAL Setpoints 51 0.79 1800 900 640 1.59 G148.03 TB-8-1 4'/2S 4'/2s 1.00 300 300 410 137% 320 320 107% G148.03 TB-8-2 4'/2S 4'/2s 1.00 300 300 385 128% 290 290 97% G148.03 TB-8-3 4'/2S 4'/2s 1.00 300 300 90 30% 300 300 100% G148.03 TB-8-4 4'/2S 4'/2s 1.00 300 300 415 138% 315 315 105% G148.03 TB-8-5 4'/2S 4'12s 1.00 300 300 140 47% 315 315 105% G148.03 TB-8-6 4728 4'/2s 1.00 300 300 395 132% 310 310 103% Address Duct dia Cooling Heating Min CAL Setpoints 52 0.79 1800 900 640 1.8 G143 TB-9-1 4'/2S 4'/2S 1.00 325 325 315 97% 315 315 97% G143 TB-9-2 4'/2S 4'/2S 1.00 325 325 315 97% 310 310 95% G143 TB-9-3 4'/2S 4'/2S 1.00 325 325 85 26% 315 315 97% G143 TB-9-4 4'/2S 4'/2S 1.00 325 325 170 52% 350 350 108% COATS TB-9-5 8" 8" 1.00 125 125 135 108% 130 130 104% G135 TB-9-6 10" 10" 1.00 400 400 205 51% 360 360 90% G136 TB-9-7 10" 10" 1.00 400 400 175 44% 360 360 90% G134 TB-9-8 4728 4'/2S 1.00 150 150 155 103% 140 140 93% G134 TB-9-9 4'/2S 4728 1.00 150 150 170 113% 135 135 90% G133 TB-9-10 8" 8" 1.00 100 100 80 _ 80% 110 110 110% Address Duct dia Cooling Heating Min CAL Setpoints 53 1.06 2625 1250 750 3.03 REMARKS: Page 150 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: AHU-3 TECH: KC AREA: GREAT ROOM FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 2810 MODEL XTI-054X054- TOTAL DESIGN CFM 5000 4812 MODEL HAJA046A ESP 2.9 1.64 "RISE O.S.A. CFM 1500 1654 SERIAL NUMBER ACRMXTO173 TOTAL OUTLET CFM 5005 4785 MOTOR DATA MOTOR BALDOR HP 7.5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 21.7-20/10 FRAME 213T ACTUAL VOLTS 484,488,486 ACTUAL AMPS 8.3,8.1,8.2 STARTER DATA STARTER SQUARE D MODEL SIZE CLASS THERMALS ADJUSTABLE 9-13 RATING SET TO 10 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VP75 SHEAVE x BORE 1 3/8 DRIVEN 1B 46 SDS SHEAVE x BORE 1 11/16 BELTS AX 72 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -0.75 "S.P. -0.86 "S.P. -0.11 "DROP HEAT COIL -0.86 "S.P. -1.03 "S.P. -0.17 "DROP COOL COIL -1.03 "S.P. -1.28 "S.P. -0.25 "DROP FAN -1.28 "S.P. _ 0.36 "S.P. 1.64 "RISE REMARKS: VELGRID COIL ,SIZE;42"X43"= 12.5'SQ. X 385 FPM = 4812 CFM TRAVRES OSA ;18"duct = 1.76'sq x 940 fpm = 1654 cfm Page 151 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/10/07 SYSTEM: AHU-3 TECH: kc SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G ROOM 3-1 24/8 24/8 1.00 385 385 315 82% 360 360 94% G ROOM 3-2 24/8 24/8 1.00 385 385 285 74% 350 350 91% G ROOM 3-3 24/8 24/8 1.00 385 385 370 96% 370 370 96% G ROOM 3-4 24/8 24/8 1.00 385 385 90 23% 350 350 91% G ROOM 3-5 24/8 24/8 1.00 385 385 350 91% 360 360 94% G ROOM 3-6 24/8 24/8 1.00 385 385 520 135% 380 380 99% G ROOM 3-7 24/8 24/8 1.00 385 385 460 119% 380 380 99% G ROOM 3-8 24/8 24/8 1.00 385 385 355 92% 370 370 96% G ROOM 3-9 24/8 24/8 1.00 385 385 360 94% 375 375 97% G ROOM 3-10 24/8 24/8 1.00 385 385 250 65% 360 360 94% G ROOM 3-11 24/8 24/8 1.00 385 385 560 145% 380 380 99% G ROOM 3-12 24/8 24/8 1.00 385 385 500 130% 370 370 96% G ROOM 3-13 24/8 24/8 1.00 385 385 505 131% 380 380 99% TOTALS 5005 4920 4785 REMARKS: Page 152 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-1 TECH: FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 835 MODEL 445 CPSA TOTAL DESIGN CFM 36,000 37680 SIZE 1825892900- ESP 2.0" 2.03 "RISE JOB 00/000701 TOTAL OUTLET CFM 36,000 37680 SERIAL NUMBER MOTOR DATA MOTOR RELIANCE HP 25 NAMEPLATE SPEED 1755 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 63/31.5 FRAME 284T ACTUAL VOLTS 488,489,487 ACTUAL AMPS 25,26,25 STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE CLASS THERMALS adjustable 15-37 RATING set to 31.5 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3TB 74 Q1 SHEAVE x BORE 1 7/8 DRIVEN 3TB154 Q1 SHEAVE x BORE 2 7/16 BELTS BX 112 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE IN OUT IFAN -1.31 "S.P. 0.72 "S.P. 2.03 "RISE REMARKS: DUCT TRAVERSE NOT AVAILABLE Page 153 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-2 TECH: KC PLAN M 110.1 C SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM cyo G2 EF-1-1 58 X 30" 58X30" 12.00 18000 1500 2020 135% 1640 19680 109% G1 EF-1-2 50 X 36 50X36" 12.50 18000 1440 1196_ 83% 1440 18000 100% REMARKS: Page 154 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-2 TECH: KC FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 830 MODEL 445 CPSA TOTAL DESIGN CFM 36,000 36479 SERIAL NUMBER 182S89900- ESP 2.0" 1.71 "RISE SERIAL NUMBER 00/0002001 TOTAL OUTLET CFM 36,000 36076 MOTOR DATA MOTOR RELIANCE HP 25 NAMEPLATE SPEED 1755 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 63/31.5 FRAME 284T ACTUAL VOLTS 488,489,487 ACTUAL AMPS 35,24,25 STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE CLASS THERMALS adjustable 12-37 RATING set to 31.5 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3TB 75 Q1 SHEAVE x BORE 1 7/8 DRIVEN 3TB154 Q1 SHEAVE x BORE 2 7/16 BELTS BX 112 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE IN OUT IFAN -1.48 "S.P. 0.23 "S.P. I 1.71 I"RISE REMARKS: DUCT TRAVERS; SIZE,96" X 24" =16.3'sq X 2238 FPM = 36479 CFM Page 155 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-2 TECH: KC PLAN M110 1B SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM ok G2 EF-2-1 96 X 24" 96X24" 16.00 24000 1500 1490 99% 1490 23840 99% G1 EF-2-2 22 X 50" 22X50" 7.60 12000 1579 1565 99% 1610 12236 102% REMARKS: Page 156 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-3 TECH: kc FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 830 MODEL 445 CPSA TOTAL DESIGN CFM 36,000 32883 SERIAL NUMBER 182S892900- ESP 2.0" 2.32 "RISE SERIAL NUMBER 00/0003301 TOTAL OUTLET CFM 36,000 32651 MOTOR DATA MOTOR RELIANCE HP 25 NAMEPLATE SPEED 1755 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 63/31.5 FRAME 284T ACTUAL VOLTS 488,489,487 ACTUAL AMPS 23,24,23 STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE CLASS THERMALS adjustable 15-45 RATING set to 31.5 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3TB 74 Q1 SHEAVE x BORE 1 7/8 DRIVEN 3TB154 Q1 SHEAVE x BORE 2 7/16 BELTS BX 112 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE IN OUT FAN -1.68 "S.P. 0.64 "S.P. 2.32 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: DUCT TRAVERS; SIZE,36"X 45" =11.25'sq X 2923 FPM = 29580CFM Page 157 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-3 TECH: KC PLAN M110.1A SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G2 EF-3-1 24 X 86" 24X86" 14.30 21000 1469 1740 118% 1320 18876 90% G1 EF-3-2 18 X 76" 18X76" 9.50 15000 1579 1050 67% 1450 13775 92% REMARKS: Page 158 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-4 TECH: kc FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM MODEL 445-CPSA TOTAL DESIGN CFM 36,000 32619 SERIAL NUMBER 182S89900- ESP 2.0" 2.02 "RISE SERIAL NUMBER 00/0006001 TOTAL OUTLET CFM 36,000 33615 MOTOR DATA MOTOR BALDOR HP 25 NAMEPLATE SPEED 1770 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 60/30 FRAME 284T ACTUAL VOLTS 488,488,489 ACTUAL AMPS 25,26,25 STARTER DATA STARTER DANFOSS VFD MODEL VLT 6000 SIZE CLASS THERMALS ELECTRONIC RATING SET TO 30 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3TB 70 Q1 SHEAVE x BORE 1 7/8 DRIVEN 3TB 154 Q1 SHEAVE x BORE 2 7/16 BELTS BX 112 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE IN OUT IFAN -1.18 "S.P. 0.84 "S.P. I 2.021"RISE REMARKS: DUCT TRAVERS; SIZE,80"X 30" =16.6'sq X 1965 FPM= 32619 CFM Page 159 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-4 TECH: KC PLAN M110.1D SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G2 EF-4-1 88X68" 88X68" 41.50 18000 434 395 91% 395 16393 91% G1 EF-4-2 88X68" 88X68" 41.50 18000 434 415 96% 415 17223 96% REMARKS: Page 160 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-5 TECH: KC FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 800 MODEL 445-CPSA TOTAL DESIGN CFM 36,000 32418 SERIAL NUMBER 182S89900- ESP 2.0" 1.83 "RISE SERIAL NUMBER 00/0007401 TOTAL OUTLET CFM 36,000 32781 MOTOR DATA MOTOR BALDOR HP 25 NAMEPLATE SPEED 1770 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 60/30 FRAME 284T ACTUAL VOLTS 488,488,489 ACTUAL AMPS 22.6,22.5,22.7 STARTER DATA STARTER DANFOSS VFD MODEL VLT 6000 SIZE CLASS THERMALS ELECTRONIC RATING SET TO 30 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3TB 70 Q1 SHEAVE x BORE 1 7/8 DRIVEN 3TB 154 Q1 SHEAVE x BORE 2 7/16 BELTS BX 112 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE IN OUT IFAN -0.97 "S.P. 0.86 "S.P. I 1.831"RISE REMARKS: DUCT TRAVERS; SIZE,90" X 26" =16.25'sq X 1995 FPM= 32418 CFM Page 161 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-5 TECH: KC PLAN M110.1A SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G2222 EF-5-1 50/14 50/14 4.86 7200 1481 1840 124% 1340 6512 90% G2222 EF-5-2 50/14 50/14 4.86 7200 1481 1555 105% 1350 6561 91% G2222 EF-5-3 50/14 50/14 4.86 7200 1481 1235 83% 1345 6537 91% G2222 EF-5-4 50/14 50/14 4.86 7200 1481 1090 74% 1360 6610 92% G2222 EF-5-5 50/14 50/14 4.86 7200 1481 1010 68% 1350 6561 91% REMARKS: Page 162 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-6 TECH: AREA: HOTEL KITCHEN GREASE EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1010 MODEL 330CPSA TOTAL DESIGN CFM 16,000 16028 ESP 2.0" 2.30 "RISE TOTAL OUTLET CFM 15,284 16028 SERIAL NUMBER 182S902212-1701 MOTOR DATA MOTOR RELIANT ELECT HP 15 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 37/18.5 FRAME ACTUAL VOLTS 485,482,481 TYPE P ACTUAL AMPS 11.6,10.8,11.2 SERIAL STARTER DATA STARTER CUTTLER HAMM MODEL SIZE 2 CLASS THERMALS H2013B RATING 18.7 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2TB62 X P1 SHEAVE x BORE 1 5/8 DRIVEN 2BK114 SHEAVE x BORE 1 15/16 BELTS BX80 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -2.20 "S.P. 0.1 "S.P. 2.301"RISE REMARKS: Page 163 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-7 TECH: KC AREA: HOTEL KITCHEN DISH EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1886 MODEL 100ACE TOTAL DESIGN CFM 600 SIZE ESP 0.7 "RISE JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-00/0021501 MOTOR DATA MOTOR MARATHON HP 1/4 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115 SF 1.35 NAMEPLATE AMPS 5 FRAME 48Y ACTUAL VOLTS ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL40 SHEAVE x BORE 1/2 DRIVEN AK27 SHEAVE x BORE 3/4 BELTS 4L190 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE FAN IN OUT "S.P. "S.P. I 0.00I"RISE REMARKS: Page 164 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-9 TECH: KC AREA: HOTEL KITCHEN DISH EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1725 MODEL 100ACE TOTAL DESIGN CFM 600 590 ESP 0.7 0.60 "RISE TOTAL OUTLET CFM 600 590 MOTOR DATA MOTOR MARATHON HP 0.25 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115 SF 1.35 NAMEPLATE AMPS 5 ACTUAL VOLTS 120 ACTUAL AMPS 4 STARTER DATA STARTER NO STARTER MODEL SIZE CLASS THERMALS IN MOTOR RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL40 SHEAVE x BORE 1/2 DRIVEN AK27 SHEAVE x BORE 3/4 BELTS 4L160 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT [FAN -0.50 "S.P. 0.1 "S.P. I 0.601"RISE REMARKS: DUCT TRAVERSE; 12"0 = 0.785'sq X 440 FPM = 354 CFM DUCT TRAVERSE; 12"(25 = 0.785'sq X 751 FPM = 590 CFM Page 165 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: TECH: KC PLAN KITCHEN FLOOR 1 SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM KITCHEN HOOD 210 X4" 210X4" 5.83 5588 958 873 91% 960 5597 100% KITCHEN HOOD 50 X 36 171x3" 3.50 4275 1221 1067 0% 1277 4470 105% TOTAL 1 DUCT' 48X20 48X20"1 6.66 98631 14811 12701 0%1 1570 104561 106% REMARKS: Page 166 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-12 TECH: KC AREA: LEASED KITCHEN GREASE EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1828 MODEL 180CPSA TOTAL DESIGN CFM 5,000 SIZE ESP 1.6 JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-01/0003801 MOTOR DATA MOTOR RELIANCE HP 3 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.15 NAMEPLATE AMPS 9.3, 8.4, 4.2 FRAME 182T ACTUAL VOLTS TYPE P ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER SHEAVE x BORE DRIVEN SHEAVE x BORE BELTS SIZE x QUANTITY SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 167 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-13 TECH: KC AREA: KITCHEN DISH EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1919 MODEL 80CPV TOTAL DESIGN CFM 600 SIZE ESP 0.7 JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-01/0002302 MOTOR DATA MOTOR MARATHON HP 1/2 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115 SF 1.25 NAMEPLATE AMPS 7.2 FRAME 48 ACTUAL VOLTS TYPE SS ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 1/2 DRIVEN AK26 SHEAVE x BORE 3/4 BELTS AX31 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 168 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-14 TECH: KC AREA: AREA B TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1107 MODEL 150 ACE TOTAL DESIGN CFM 2,000 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-00/0000701 MOTOR DATA MOTOR MARATHON HP 3/4 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.25 NAMEPLATE AMPS 2.7, 2.8, 1.4 FRAME 56.00 ACTUAL VOLTS TYPE TS ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AK41 SHEAVE x BORE 3/4 BELTS AP20 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 169 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-15 TECH: KC AREA: AREA B TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1519 MODEL 150ACE TOTAL DESIGN CFM 1,680 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-00/0002101 MOTOR DATA MOTOR MARATHON HP 3/4 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.25 NAMEPLATE AMPS 2.7, 2.8, 1.4 FRAME 56.00 ACTUAL VOLTS TYPE TS ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AL54 SHEAVE x BORE 3/4 BELTS A22 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 170 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-16 TECH: KC AREA: AREA C TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1000 MODEL 165 ACE TOTAL DESIGN CFM 2,400 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-00/0003701 MOTOR DATA MOTOR MARATHON HP 3/4 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.25 NAMEPLATE AMPS 2.7, 2.8, 1.4 FRAME 56 ACTUAL VOLTS TYPE TS ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AL54 SHEAVE x BORE 3/4 BELTS A22 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 171 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-17 TECH: KC AREA: AREA C TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1216 MODEL 180 CPV TOTAL DESIGN CFM 4,000 SIZE ESP 0.5 JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-01/0005601 MOTOR DATA MOTOR A.O. SMITH HP 2 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 200, 230, 460 SF 1.15 NAMEPLATE AMPS 6.0, 5.6, 2.8 FRAME P145T ACTUAL VOLTS TYPE SCE ACTUAL AMPS STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL44 SHEAVE x BORE 7/8 DRIVEN AK49 SHEAVE x BORE 1 BELTS A41 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 172 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-19 TECH: KC AREA: AREA D TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1344 MODEL 135 CPV TOTAL DESIGN CFM 1,360 SIZE ESP 0.5 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-01/0007201 MOTOR DATA MOTOR MARATHON HP 1 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.15 NAMEPLATE AMPS 3.4, 3.2, 1.6 FRAME 56 ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AK39 SHEAVE x BORE 3/4 BELTS A31 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 173 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-20 TECH: KC AREA: AREA D TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 878 MODEL 180 CPV TOTAL DESIGN CFM 2,000 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-010008801 MOTOR DATA MOTOR A.O. SMITH HP 2 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 200, 230, 460 SF 1.15 NAMEPLATE AMPS 6.0, 5.6, 2.8 FRAME P145T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VP44 SHEAVE x BORE 7/8 DRIVEN AK71 SHEAVE x BORE 1 BELTS A44 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 174 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-21 TECH: KC AREA: AREA D TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1338 MODEL 180 CPV TOTAL DESIGN CFM 4,550 SIZE ESP 0.5 JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-01/0010401 MOTOR DATA MOTOR A.O. SMITH HP 2 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 200, 230, 460 SF 1.15 NAMEPLATE AMPS 6.0, 5.6, 2.8 FRAME P145T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL44 SHEAVE x BORE 7/8 DRIVEN AK61 SHEAVE x BORE 1 BELTS A41 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 175 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-23 TECH: KC AREA: AREA D TOILET EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1139 MODEL TOTAL DESIGN CFM 1,460 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-00/0008501 MOTOR DATA MOTOR MARATHON HP 1/2 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115 SF 1.25 NAMEPLATE AMPS 7.2 FRAME 48Z ACTUAL VOLTS TYPE SS ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 1/2 DRIVEN 1VL54 SHEAVE x BORE 3/4 BELTS A22 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 176 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-26 TECH: AREA: FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 898 MODEL 300CPSA TOTAL DESIGN CFM SIZE ESP JOB TOTAL OUTLET CFM SERIAL NUMBER 182S902212-01/0013601 MOTOR DATA MOTOR RELIANCE HP 7.5 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.15 NAMEPLATE AMPS 21.5, 19.4, 9.7 FRAME 213T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B40 SHEAVE x BORE 1 1/8 DRIVEN 2B80Q1 SHEAVE x BORE 1 15/16 BELTS BX67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 177 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-30 TECH: KC AREA: ICE RINK EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1008 MODEL 180CPV TOTAL DESIGN CFM 3,000 SIZE ESP 0.5 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-01/0018501 MOTOR DATA MOTOR BALDOR HP 1.5 NAMEPLATE SPEED 1740 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.15 NAMEPLATE AMPS 4.5, 4.2, 2.1 FRAME 145T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1 VP40 SHEAVE x BORE 7/8 DRIVEN AK54H SHEAVE x BORE 1 BELTS A41 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT IFAN "S.P. "S.P. I 0.00I"RISE REMARKS: Page 178 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-32 TECH: KC AREA: AREA C TOILET EXHAUSE FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 950 MODEL 165ACE TOTAL DESIGN CFM 2,240 SIZE ESP 0.25 JOB TOTAL OUTLET CFM SERIAL NUMBER 182590221200/0013101 MOTOR DATA MOTOR MARATHON HP 3/4 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.25 NAMEPLATE AMPS 2.7, 2.8, 1.4 FRAME 56 ACTUAL VOLTS TYPE TS ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AL54 SHEAVE x BORE 3/4 BELTS A22 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P, "S.P. 0.00 "DROP REMARKS: Page 179 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-35 TECH: KC AREA: AREA D EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1176 MODEL 180CPV TOTAL DESIGN CFM 3,300 SIZE ESP 0/5 JOB TOTAL OUTLET CFM 3,200 SERIAL NUMBER 1825902212-01/0020101 MOTOR DATA MOTOR A.O. SMITH HP 2 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 200, 230, 460 SF 1.15 NAMEPLATE AMPS 6.0, 5.6, 2.8 FRAME P145T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1 VL44 SHEAVE x BORE 7/8 DRIVEN AK54H SHEAVE x BORE 1 BELTS A41 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P. "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 180 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-36 TECH: AREA: AREA D EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1243 MODEL 150SQN TOTAL DESIGN CFM 2,710 ESP 0.4 TOTAL OUTLET CFM MOTOR DATA MOTOR marathon HP 1 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 3.4-3.2/1.6 FRAME 56.00 ACTUAL VOLTS ACTUAL AMPS NO POWER STARTER DATA STARTER N/A MODEL SIZE CLASS THERMALS IN MOTOR RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 5/8 DRIVEN AK44 SHEAVE x BORE 1 BELTS A44 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P, "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 181 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-38 TECH: KC AREA: WATER FEATURE EXHAUST FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM 1860 MODEL 70ACE TOTAL DESIGN CFM 250 SIZE ESP 0.5 JOB TOTAL OUTLET CFM SERIAL NUMBER 1825902212-00/0018101 MOTOR DATA MOTOR MARATHON HP 1/4 NAMEPLATE SPEED 1725 PHASE 1 NAMEPLATE VOLTS 115 SF 1.35 NAMEPLATE AMPS 5.0 FRAME 48Y ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VL34 SHEAVE x BORE 1/2 DRIVEN AK26 SHEAVE x BORE 3/4 BELTS 4L180 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN "S.P. "S.P. 0.00 "RISE "S.P, "S.P. 0.00 "DROP "S.P. "S.P. 0.00 "DROP REMARKS: Page 182 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: MAU-3 TECH: KC AREA: LOWER HOTEL KITCHEN FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 1650 MODEL XTI-072X114- TOTAL DESIGN CFM 17800 16954 SIZE HAMA046A ESP 2 2.03 "RISE O.S.A. CFM 17800 SERIAL NUMBER ACRMXTO175 TOTAL OUTLET CFM MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 486,487,486 ACTUAL AMPS 16.1,16.8,16.0 STARTER DATA STARTER SQUARE D MODEL SIZE CLASS THERMALS ADJUSTABLE 23-32 RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B 64 SDS SHEAVE x BORE 1 5/8 DRIVEN 2B 70 SK SHEAVE x BORE 2 7/16 BELTS BX63 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -0.77 "S.P. -0.9 "S.P. -0.13 "DROP HEAT COIL -0.90 "S.P. -1.06 "S.P. -0.16 "DROP COOL COIL -1.06 "S.P. -1.25 "S.P. -0.19 "DROP FAN -1.25 "S.P. 0.78 "S.P. 2.03 "RISE REMARKS: COIL VELGRID, SIZE;100" X 55"= 38.1'SQ X 445 FPM = 16954 CFM Page 183 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/08/07 SYSTEM: MAU-3 TECH: kc AREA: LOWER HOTEL KITCHEN SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % G130.01 3-1 6" 1.00 80 80 145 181% 75 75 94% G130.01 3-2 8" 1.00 160 160 260 163% 165 165 103% G130 3-3 10" 1.00 450 450 320 71% 420 420 93% G130 3-4 10" 1.00 450 450 320 71% 410 410 91% G130 3-5 10' 1.00 450 450 340 76% 430 430 96% G130 3-6 10" 1.00 450 450 340 76% 420 420 93% G130 3-7 10' 1.00 450 450 410 91% 420 420 93% G130 3-8 8" 1.00 400 400 445 111% 395 395 99% G130 3-9 8" 1.00 400 400 150 38% 425 425 106% G130 3-10 8' 1.00 150 150 240 160% 140 140 93% G130 3-11 HOOD 13.00 3200 246 232 94% 225 2925 91% G130 3-12 HOOD 13.50 3080 228 228 100% 210 2835 92% G130 3-13 HOOD 13.00 2850 219 162 74% 205 2665 94% G130 3-14 HOOD 13.50 3080 228 191 84% 205 2768 90% G139 3-15 8' 1.00 250 250 340 136% 260 260 104% G139 3-16 8' 1.00 250 250 300 120% 240 240 96% G139 3-17 8' 1.00 250 250 360 144% 240 240 96% G139 3-18 8' 1.00 250 250 340 136% 255 255 102% REMARKS: Page 184 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: MAU-4 TECH: KC AREA: UPPER HOTEL KITCHEN FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 1400 MODEL XTI-084X102- TOTAL DESIGN CFM 19530 18317 SIZE HAMA046A ESP 2 2.30 "RISE SERIAL NUMBER ACRMXTO176 O.S.A. CFM 19530 18317 TOTAL OUTLET CFM 17780 16957 MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 486,488,487 ACTUAL AMPS 17,18,18 STARTER DATA STARTER SQUARE D MODEL SIZE CLASS THERMALS ADJUSTABLE 23-32 RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B 52 SDS SHEAVE x BORE 1 5/8 DRIVEN 2B 68 SF SHEAVE x BORE 2 11/16 BELTS BX112 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -1.03 "S.P. 0 "SP. 1.03 "DROP HEAT COIL 0.00 "S.P. -1.28 "S.P. -1.28 "DROP COOL COIL -1.28 "S.P. -1.46 "S.P.. -0.18 "DROP FAN -1.46 "S.P. 0.84 "S.P. 2.30 "RISE REMARKS: COIL VELGRID, SIZE;69 X 90"= 43.1'SQ X 425 FPM = 18317 CFM Page 185 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/08/07 SYSTEM: MAU-4 TECH: kc AREA: UPPER HOTEL KITCHEN SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM P130 4-1a HOOD 109x20" 1.00 2230 2230 3140 141% 2160 2160 97% P130 4-1b HOOD 109x20" 1.00 2230 2230 3055 137% 2190 2190 98% P130 4-2a 44/34 14x24" 2.33 6000 2575 2250 87% 2380 5545 92% P130 4-2b 44/34 12x12" 1.00 2500 2500 2250 90% 2360 2360 94% P130 4-3 HOOD 174x20" 1.00 3420 3420 3380 99% 3320 3320 97% P130.02 FCU-B1-01 12" 12" 0.79 700 892 1340 150% 880 691 99% P130.02 FCU-B1-02 12" 12" 0.79 700 892 1260 141% 880 691 99% REMARKS: Page 186 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/24/2007 SYSTEM: MAU-5 TECH: kc AREA: RETAIL FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM NA 2010 MODEL XTI-051X075- TOTAL DESIGN CFM 10200 10929 MODEL HAKA046A ESP 2.5 2.63 "RISE O.S.A. CFM 9000 9882 SERIAL NUMBER ACRMXT0185 TOTAL OUTLET CFM MOTOR DATA MOTOR BALDOR HP 10 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 28.1-26.6/13.3 FRAME 215T ACTUAL VOLTS 486,487,488 ACTUAL AMPS 11.7,11.8,11.5 STARTER DATA STARTER SQUARED MODEL SIZE CLASS THERMALS ADJUSTABLE 12-18 RATING SET AT 13.3 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2JVS 230 (8") SHEAVE x BORE 1 3/8 DRIVEN 2874 SK SHEAVE x BORE 2 3/16 BELTS AX 98 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -1.40 "S.P. -1.45 "S.P. -0.05 "DROP HEAT COIL -1.45 "S.P. -1.55 "S.P. -0.10 "DROP COOL COIL -1.55 "S.P. -1.85 "S.P. -0.30 "DROP FAN -1.85 "S.P. 0.78 "S.P. 2.63 "RISE REMARKS: COIL VELGRID, SIZE;62 X 41"= 17.6'SQ X 621 FPM = 10929CFM Page 187 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/13/2007 SYSTEM: MAU-6 TECH: KC AREA: SE RETAIL FAN DATA DESIGN ACTUAL MAKE york FAN RPM N/A 2140 MODEL XTI-060X078- TOTAL DESIGN CFM 11200 10664 MODEL HALA046A ESP 2.5 4.15 "RISE O.S.A. CFM 11200 SERIAL NUMBER ACRMXT0166 TOTAL OUTLET CFM 11300 MOTOR DATA MOTOR BALDOR HP 15 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 41-38/19 FRAME 254T ACTUAL VOLTS ACTUAL AMPS STARTER DATA STARTER SQUARED MODEL SIZE CLASS THERMALS ADJUSTABLE 17-25 RATING SET-19 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP75 SHEAVE x BORE 1 5/8 DRIVEN B 56 SHEAVE x BORE 2 3/16 BELTS AX91 SIZE x QUANTITY SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -1.05 "S.P. -1.12 "S.P. -0.07 "DROP HEAT COIL -1.12 "S.P. -1.24 "S.P. -0.12 "DROP COOL COIL -1.24 "S.P. -1.35_"S.P. -0.11 "DROP FAN -1.35 "S.P. 2.8 "S.P. 4.15 "RISE REMARKS: COIL VELGRID, SIZE;66 X 47"= 21.5'SQ X 496 FPM = 10664 CFM Page 188 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/31/2007 SYSTEM: MAU-7 TECH: KC AREA: NE RETAIL FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM MODEL XTI-060X078- TOTAL DESIGN CFM 11000 10243 SIZE HALA046A ESP 2.2 2.54 "RISE O.S.A. CFM 11000 10243 SERIAL NUMBER ACRMXT0167 TOTAL OUTLET CFM MOTOR DATA MOTOR BALDOR HP 15 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 41-38/19 FRAME ACTUAL VOLTS 488,487,488 TYPE ACTUAL AMPS 10,9,10.8,10.9 SERIAL STARTER DATA STARTER SQUARE D MODEL SIZE CLASS THERMALS ADJUSTABLE 17-25 RATING SET AT 19 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER SJS 230-2 (8") SHEAVE x BORE 1 5/8 DRIVEN 2B 74 SK SHEAVE x BORE 2 3/16 BELTS AX98 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -1.90 "S.P. -2.01 "S.P. -0.11 "DROP HEAT COIL -2.01 "S.P. -2.12 "S.P. -0.11 "DROP COOL COIL -2.12 "S.P. -2.25 "S.P. -0.13 "DROP FAN -2.25 "S.P. 0.29 "S.P. 2.54 "RISE REMARKS: DUCT TRAVERS, SIZE;40" X 24" = 6.6' SQ X 1552 FPM =10243 CFM Page 189 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: MAU-8 TECH: KC AREA: NW RETAIL FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM 2825 NOT RUNNING MODEL XTI-036X048- TOTAL DESIGN CFM 3200 0 SIZE HAHA046A ESP 2.2 O.S.A. CFM 3200 SERIAL NUMBER ACRMXTO168 TOTAL OUTLET CFM 3725 MOTOR DATA MOTOR BALDOR HP 5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 14-13.8/6.9 FRAME 184T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER SQUARED MODEL SIZE CLASS THERMALS ADJUSTABLE 5.5-8 RATING SET AT 6.9 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VP 56 SHEAVE x BORE 1 1/8 DRIVEN AK 30 QT SHEAVE x BORE 1 3/16 BELTS AX 57 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER "S.P. "S.P. 0.00 "DROP HEAT COIL "S.P. "S.P. 0.00 "DROP COOL COIL "S.P. "S.P. 0.00 "DROP FAN "S.P. "S.P. 0.00 "RISE REMARKS: Page 190 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: MAU-9 TECH: AREA: BOILER ROOM FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 1030 AT 60 HZ MODEL XTI-090X120- TOTAL DESIGN CFM 25000 24420 MODEL JAMA046A ESP 1.2 1.00 "RISE O.S.A. CFM 25000 SERIAL NUMBER ACRMXTO169 TOTAL OUTLET CFM 25000 MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 486,488,489 ACTUAL AMPS 15.1,15.4,15.2 STARTER DATA STARTER YORK VFD MODEL SIZE CLASS THERMALS ELECTRONIC RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 3B 34 SH SHEAVE x BORE 1 5/8 DRIVEN 3B 80 SK SHEAVE x BORE 2 7/16 BELTS BX62 SIZE x QUANTITY 3 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -0.24 "S.P. -0.38 "S.P. -0.14 "DROP HEAT COIL -0.38 "S.P. -0.53 "S.P. -0.15 "DROP AIR WASH -0.53 "S.P. -0.68 "S.P. -0.15 "DROP FAN -0.68 "S.P. 0.32 "S.P. 1.00 "RISE REMARKS: DUCT TRAVERS , SIZE;34 X 70" =16.5'SQ X 1480 FPM = 24420 CFM AT 55HZ Page 191 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: MAU-1 TECH: AREA B CORR FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM 1862 MODEL XTO-036X048- TOTAL DESIGN CFM 2000 0 SIZE HAF-A046A ESP 1 0.00 "RISE JOB O.S.A. CFM 2000 SERIAL NUMBER ACRMXTO147 TOTAL OUTLET CFM 2000 MOTOR DATA MOTOR BALDOR HP 2 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 208, 230, 460 SF 1.15 NAMEPLATE AMPS 5.9, 5.6, 2.8 FRAME 145T ACTUAL VOLTS TYPE ACTUAL AMPS SERIAL STARTER DATA STARTER MODEL SIZE CLASS THERMALS RATING INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 1VP34 SHEAVE x BORE 7/8 DRIVEN BK30QT SHEAVE x BORE 1 3/16 BELTS AX53 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER "S.P. "S.P. 0.00 "DROP HEAT COIL "S.P. "S.P. 0.00 "DROP COOL COIL "S.P. "S.P. 0.00 "DROP FAN "S.P. "S.P. 0.00 "RISE REMARKS: Page 192 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-1 TECH: KC AREA: ELEVATORS 4/5 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1343 MODEL 245QMX TOTAL DESIGN CFM 15200 15862 SIZE ESP 0.5 0.43 "RISE JOB SERIAL NUMBER 182C904923- 00/0000701 MOTOR DATA MOTOR BALDOR HP 7.5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 23 FRAME 213T ACTUAL VOLTS 211,210,209 ACTUAL AMPS 17,18,17 STARTER DATA STARTER CUTTLER HAM MODEL SIZE NEMA 1 CLASS THERMALS H2013B RATING 23 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2BK44 SHEAVE x BORE 2 3/8 DRIVEN 2TB56 SHEAVE x BORE Q1-1 5/8 BELTS BX67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.22 "S.P. 0.21 "S.P. I 0.43 "RISE REMARKS: VELGRID:44"X 118"= 36.05'SQ X 440 FPM = 15862 CFM Page 193 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-2 TECH: KC AREA: STAIR 2 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 817 MODEL 245QMXS TOTAL DESIGN CFM 8100 8780 SIZE ESP 0.5 0.41 "RISE JOB SERIAL NUMBER 182590492- 002301 MOTOR DATA MOTOR CENTRA HP 3 NAMEPLATE SPEED 1765 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 8.6/4.3 FRAME S182J ACTUAL VOLTS 209,211,210 TYPE ACTUAL AMPS 5.7,5.8,5.8 SERIAL STARTER DATA STARTER CUTLER HAM MODEL SIZE NEMA 0 CLASS THERMALS H2O10B RATING 9.5 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP42 SHEAVE x BORE 1 1/8 DRIVEN 2AK64 SHEAVE x BORE 1 5/8 BELTS A67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.21 "S.P. 0.2 "S.P. I 0.41 "RISE I REMARKS: VELGRID 24"X 118" = 19.6'SQ X 448FPM= 8780CFM Page 194 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-3 TECH: KC AREA: ELEVATORS 13/14 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1406 MODEL 245QMX TOTAL DESIGN CFM 16000 14550 SIZE ESP 0.5 0.43 `RISE JOB SERIAL NUMBER 1825904923-00/0003901 MOTOR DATA MOTOR BALDOR HP 7.5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 23 FRAME 213T ACTUAL VOLTS 211,210,211 TYPE ACTUAL AMPS 18.5,18.6,18.4 SERIAL STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE NEMA SIZE 1 CLASS THERMALS H2013B RATING 23 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2TB36 SHEAVE x BORE P1-1 3/8 DRIVEN 2TB56 SHEAVE x BORE Q1-1 5/8 BELTS BX65 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.19 "S.P. 0.24 "S.P. I 0.43 I"RISE I REMARKS: VELGRID; SIZE 50"X 112" = 38.8 X 375 FPM = 14550 CFM Page 195 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-4 TECH: KC AREA: ELEVATORS 16 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 787 MODEL 245QMX TOTAL DESIGN CFM 7600 8229 SIZE ESP 0.5 0.41 "RISE JOB SERIAL NUMBER 182S904923-00/0005701 MOTOR DATA MOTOR BALDOR HP 3 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 9.4 FRAME 182T ACTUAL VOLTS 211,210,211 TYPE ACTUAL AMPS 7.3,7.4,7.6 SERIAL STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE NEMA 0 CLASS THERMALS 82010B RATING 9.5 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP40 SHEAVE x BORE 1 1/8 DRIVEN 2TB70 SHEAVE x BORE 1 5/8 BELTS A67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT I FAN -0.19 "S.P. 0.22 "S.P. I 0.41 'RISE REMARKS: VELGRID; SIZE 71"X 44" =21.6'X 381 FPM= 8229 CFM Page 196 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/30/2007 SYSTEM: SMF-5 TECH: KC AREA: STAIR 8 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1446 MODEL 245QMX TOTAL DESIGN CFM 16,500 16,082 SIZE ESP 0.5 0.42 "RISE JOB SERIAL NUMBER 1825904923-00/0007501 MOTOR DATA MOTOR BALDOR HP 7.5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 23 FRAME 213T ACTUAL VOLTS 210,211,212 TYPE ACTUAL AMPS 17.5,18.4,17.8 SERIAL STARTER DATA STARTER CUTLER HAMMER MODEL SIZE NEMA SIZE 1 CLASS THERMALS H2013B RATING ADJ 18.7-30 INSTALLED 3 THERMALS RATING SET AT 23 REQUIRED DRIVE DATA DRIVER 2TB36 SHEAVE x BORE P1-1 3/8 DRIVEN 2TB56 SHEAVE x BORE 1 5/8 BELTS BX65 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FAN -0.20 "S.P. 0.22 "S.P. I 0.421"RISE REMARKS: VELGRID; SIZE 83"X 65"= 37.4'X 430 FPM= 16082 CFM Page 197 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-6 TECH: KC AREA: ELEVATORS 10 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 913 MODEL 245QMX TOTAL DESIGN CFM 15200 SIZE ESP 0.5 JOB SERIAL NUMBER 182590492300/0009301 MOTOR DATA MOTOR BALDOR HP 3 NAMEPLATE SPEED 1725 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 9.4 FRAME 182T ACTUAL VOLTS 211,213,212 TYPE ACTUAL AMPS 8.7,8.4,8.5 SERIAL STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE NEMA SIZE 0 CLASS THERMALS H2O10B RATING 9.4 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP42 SHEAVE x BORE 1 1/8 DRIVEN 2AK64 SHEAVE x BORE 1 5/8 BELTS A65 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN „S.P. "S.P. I 0.001"RISE REMARKS: VELGRID 24"X 118"= 19.6'SQ X 0 FPM= 0 CFM FIRE DAMPER CLOSED Page 198 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-7 TECH: KC AREA: STAIR 5 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1304 MODEL 245QMX TOTAL DESIGN CFM 14700 13545 SIZE ESP 0.5 0.42 "RISE JOB SERIAL NUMBER 1825904923-00/0010901 MOTOR DATA MOTOR BALDOR HP 7.5 NAMEPLATE SPEED 1750 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 23 FRAME 213T ACTUAL VOLTS 212,213,211 TYPE ACTUAL AMPS 20.1,20.0,20.2 SERIAL STARTER DATA STARTER CUTLER HAMMEF MODEL SIZE NEMA SIZE 1 CLASS THERMALS H2013B RATING 23 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2TB40 SHEAVE x BORE 1 3/8 DRIVEN 2BK54 SHEAVE x BORE 1 5/8 BELTS BX67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.18 "S.P. 0.24 "S.P. I 0.42 I"RISE REMARKS: VELGRID; SIZE 58"X 65"= 26.1'X 519 FPM = 13545 CFM Page 199 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-8 TECH: KC AREA: STAIR 3 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 985 MODEL 245QMXS TOTAL DESIGN CFM 10500 10094 SIZE ESP 0.5 0.45 "RISE JOB SERIAL NUMBER 1825904923-00/0012701 MOTOR DATA MOTOR A.O. SMITH HP 5 NAMEPLATE SPEED 1745 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 12.8/6.4 FRAME S184T ACTUAL VOLTS 210,211,210 TYPE MOGB ACTUAL AMPS 8.5,8.6,8.4 SERIAL STARTER DATA STARTER CUTLER HAM MODEL SIZE NEMA 1 CLASS THERMALS H2012B RATING 14 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP50 SHEAVE x BORE 1 1/8 DRIVEN 2TB94 SHEAVE x BORE 1 5/8 BELTS A70 SIZE x QUANTITY 1 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.29 "S.P. 0.16 "S.P. I 0.45 "RISE REMARKS: VELGRID: 118"X 24" = 19.6'SQ X 515 FPM= 10094 CFM Page 200 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: SMF-9 TECH: KC AREA: ELEVATORS 8 FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1021 MODEL 245QMX TOTAL DESIGN CFM 11000 10736 SIZE ESP 0.5 0.40 "RISE JOB SERIAL NUMBER 182S904923-00/0014301 MOTOR DATA MOTOR BALDOR HP 5 NAMEPLATE SPEED 1740 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 16.1 FRAME 184T ACTUAL VOLTS 209,210,209 TYPE ACTUAL AMPS 11.0,11.2,11.1 SERIAL STARTER DATA STARTER CUTLER HAM MODEL SIZE NEMA 1 CLASS THERMALS H2012B RATING 16 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2VP50 SHEAVE x BORE 1 1/8 DRIVEN 2B70 SHEAVE x BORE 1 11/16 BELTS A65 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -0.20 "S.P. 0.2 "S.P. 0.40 f"RISE REMARKS: VELGRID: 82"X 43"=24.4'SQ X 440 FPM = 10736 CFM Page 201 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: PHWP-1 TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 1120 1150 MODEL 1510 HEAD (FT) 50 48.5 IMP. SIZE 8.25 SUCTION (PSI) N/A 55 SERIAL C014656-01060 DISCHARGE(PSI) N/A 76 NO FLOW HD(FT) N/A 66 RPM 1800 1775 MOTOR DATA MOTOR US ELECTRIC HP 25 NAMEPLATE SPEED 1775 PH 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 66-60/30 FR 284T ACTUAL VOLTS 25.1,25.0,25.1 ACTUAL AMPS 490,488,489 STARTER DATA STARTER CUTLER HAMMER MODEL THERMALS ADJUSABLE 12-37 RATING SET AT 30 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 8"TA BALANCING VALVE IS SET AT 5.5 AND READING 28'=1150 GPM Page 202 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: PHWP-2 TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 1120 1200 MODEL 1510 HEAD (FT) 50 48.5 IMP. SIZE 8.25 SUCTION (PSI) N/A 58 SERIAL C014656-02C60 DISCHARGE (PSI) N/A 79 NO FLOW HD (FT) N/A 65 RPM 1800 MOTOR DATA MOTOR US ELECTRIC HP 25 NAMEPLATE SPEED 1775 PH 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 66-60/30 FR 284T ACTUAL VOLTS 26.1,25.8,25.7 ACTUAL AMPS 489,490,490 STARTER DATA STARTER CUTLER HAMMER MODEL THERMALS ADJUSABLE 12-37 RATING SET AT 30 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 8"TA BALANCING VALVE IS SET AT 5.5 AND READING 30' =1200 GPM Page 203 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: PHWP-3 TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 560 590 MODEL 1510 BF HEAD (FT) 50 50.8 IMP. SIZE 8 SUCTION (PSI) N/A 57 SERIAL C014654-01B60 DISCHARGE (PSI) N/A 79 NO FLOW HD (FT) N/A 69.3 RPM 1800 1775 MOTOR DATA MOTOR US ELECTRIC HP 15 NAMEPLATE SPEED 1775 PH 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 41-39/19.5 FR 254T ACTUAL VOLTS 491,490,489 ACTUAL AMPS 14.4,14.5,15.0 STARTER DATA STARTER CUTLER HAMMER MODEL THERMALS ADJUSABLE 12-37 RATING SET AT 19.5 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 6"TA BALANCING VALVE IS SET AT 3.3 AND READING 40' =590 GPM Page 204 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: HWP-1 DOMESTIC WATER HEATER TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 343 0 NOTE-1 MODEL 1510 BF HEAD (FT) 50 62.3 IMP.SIZE 7.625 SUCTION (PSI) N/A 48 SERIAL CO14652-02B60 DISCHARGE(PSI) N/A 75 CAT.#: NO FLOW HD(FT) N/A 62.3 RPM 1800 1760 MOTOR DATA MOTOR EMERSON HP 10 NAMEPLATE SPEED 1760 PH 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 27.3-25.2/12.6 FR 215T ACTUAL VOLTS 489,488,489 ACTUAL AMPS STARTER DATA STARTER DANFOSS MODEL VLT 6000 SIZE N/A CLASS THERMALS ELECTRONIC RATING SET TO 12 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 6"TA BALANCING VALVE IS SET AT 3.3 AND READING 0'=0 GPM NOTE-1 DOMESTIC HOT WATER MAINTAINS PRESSURE UNTIL WATER IS USED Page 205 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: SYSTEM: HWP-2 DOMESTIC WATER HEATER TECH: PUMP DATA DESIGN ACTUAL MAKE B+G GPM 343 0 NOTE-1 MODEL 1510 BF HEAD (FT) 50 62.3 IMP.SIZE 7.625 SUCTION (PSI) N/A 48 SERIAL C014652-01B60 DISCHARGE(PSI) N/A 75 CAT.#: NO FLOW HD(FT) N/A 62.3 RPM 1800 1760 MOTOR DATA MOTOR EMERSON HP 10 NAMEPLATE SPEED 1760 PH 3 NAMEPLATE VOLTS 208-230/460 SF 1.15 NAMEPLATE AMPS 27.3-25.2/12.6 FR 215T ACTUAL VOLTS 490,489,488 ACTUAL AMPS STARTER DATA STARTER DANFOSS MODEL VLT 6000 SIZE N/A CLASS THERMALS ELECTRONIC RATING SET TO 12 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 6"TA BALANCING VALVE IS SET AT 3.3 AND READING 0'=0 GPM NOTE-1 DOMESTIC HOT WATER MAINTAINS PRESSURE UNTIL WATER IS USED Page 206 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: SHWP-1 HEATING TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 825 860 MODEL 1510 BF HEAD (FT) 120 115.5 IMP. SIZE 11.375 SUCTION (PSI) N/A 49 SERIAL C014653-01060 DISCHARGE(PSI) N/A 99 NO FLOW HD(FT) N/A 138 RPM 1800 1785 MOTOR DATA MOTOR EMERSON HP 60 NAMEPLATE SPEED 1785 PH 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 150/75 FR 364T ACTUAL VOLTS 490,489,488 ACTUAL AMPS 48.5,48.6,48.5 STARTER DATA STARTER DANFOSS MODEL VLT 6000 SIZE N/A CLASS THERMALS ELECTRONIC RATING SET TO 75 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: 8"TA BALANCING VALVE IS SET AT 12.0 AND READING 2.2' =860 GPM Page 207 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: SHWP-2 HEATING TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 825 860 MODEL 1510 BF HEAD (FT) 120 115.5 IMP. SIZE 11.375 SUCTION (PSI) N/A 49 SERIAL CO14653-02C60 DISCHARGE (PSI) N/A 99 NO FLOW HD (FT) N/A 138 RPM 1800 1785 MOTOR DATA MOTOR EMERSON HP 60 NAMEPLATE SPEED 1785 PH 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 150/75 FR 364T ACTUAL VOLTS 488,489,488 ACTUAL AMPS 49.3,49.5,49.4 STARTER DATA STARTER DANFOSS MODEL VLT 6000 SIZE N/A CLASS THERMALS ELECTRONIC RATING SET TO 75 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: Page 208 BTC SERVICES WATER TERMINAL TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/11/2007 SYSTEM: HEATING WATER TECH: KC FLOW REQUIRED TEST 1 FINAL STATION METER SIZE PD GPM PD GPM % PD GPM SET PT % MAU-1 T/A 1.5" 7.1 2 9.5 134% 3' 7.5 2.0 106% MAU-2 T/A 1.5" 7.1 0% 3' 7.5 2.0 106% MAU-3 T/A 2.5" 55.4 1.5' 75 135% 25' 55 3.0 99% MAU-4 T/A 2.5" 60.8 1.6' 80 132% 10' 62 3.5 102% MAU-5 T/A 2" 28 3' 43 154% 23' 26 1.5 93% MAU-6 T/A 2" 41.9 4' 50 119% 20' 41 2.0 98% MAU-7 T/A 2" 41.2 2' 37 90% 2' 37 4 (open) 90% MAU-8 T/A 1.5" 12 1' 15 125% 20' 11 1.0 92% MAU-9 T/A 3" 93.6 35' 175 187% 77' 90 3.0 96% AHU-1 T/A 3" 51 1' 90 176% 23' 51 3.0 100% AHU-2 T/A 2.5" 48.5 1' 64 132% 14' 48 3.0 99% AHU-3 T/A 2" 16.6 4' 50 301% 50' 15 0.5 90% REMARKS: Page 209 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/5/2007 SYSTEM: CWP-1 CHILLED WATER TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 1385 1300 MODEL 1510 BF HEAD (FT) 130 136 IMP. SIZE 11.75 SUCTION (PSI) N/A 55 SERIAL C014647 02C60 DISCHARGE (PSI) N/A 114 CAT. #: NO FLOW HD (FT) N/A 152 RPM 1800 1785 MOTOR DATA MOTOR EMERSON HP 100 NAMEPLATE SPEED 1785 PH 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 228/114 FR ACTUAL VOLTS 485,489,488 ACTUAL AMPS 65,66,65 STARTER DATA STARTER DANFOSS VFD MODEL VLT6000 SIZE CLASS THERMALS ELECTRONIC RATING SET AT 114 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: T/A 8" CIRCUIT SETTER;SET AT 12 TURNS OR OPEN READING 5.0'=1300 GPM Page 210 BTC SERVICES PUMP TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/5/2007 SYSTEM: CWP-2 CHILLED WATER TECH: KC PUMP DATA DESIGN ACTUAL MAKE B+G GPM 1385 1310 MODEL 1510 BF HEAD (FT) 130 135 IMP. SIZE 11.75 SUCTION (PSI) N/A 55 SERIAL C014647 01060 DISCHARGE(PSI) N/A 113.5 CAT.#: NO FLOW HD(FT) N/A 152 RPM 1800 1785 MOTOR DATA MOTOR EMERSON HP 100 NAMEPLATE SPEED 1785 PH 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 228/114 FR ACTUAL VOLTS 488,488,489 ACTUAL AMPS 66,67,66 STARTER DATA STARTER DANFOSS VFD MODEL VLT6000 SIZE CLASS THERMALS ELECTRONIC RATING SET AT 114 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DIRECT DRIVE REMARKS: T/A 8"CIRCUIT SETTER;SET AT 12 TURNS OR OPEN READING 5.2'=1310 GPM Page 211 BTC SERVICES WATER TERMINAL TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 04/07/04 SYSTEM: CHILLED WATER TECH: kc FLOW REQUIRED TEST 1 FINAL STATION METER SIZE PD GPM PD GPM % PD GPM SET PT % MAU-1 T/A 11/2" 11.7 0% 17' 11 1.0 94% MAU-2 T/A 1 1/2" 11.7 0% 5.0' 11 2.0 94% MAU-3 T/A 3" 91 1 98 108% 2.4' 95 6.0 104% MAU-4 T/A 3" 104.1 2.1 145 139% 7.0' 110 5.0 106% MAU-5 T/A 2" 46 4' 51 111% 7.0' 45 3.0 98% MAU-6 T/A 2" 32.8 2.6 40 122% 12' 32 2.0 98% MAU-7 T/A 2" 32.2 4.4 54 168% 15' 35 2.0 109% MAU-8 T/A 1 1/2" 9.4 2.5" 24 255% 20' 10 1.0 106% AHU-1 T/A 3" 56.3 1.8' 55 98% 6.5' 55 4.0 98% AHU-2 T/A 2 1/2" 76.7 1.2' 70 91% 1.2' 70 8 open 91% AHU-3 T/A 2" 25.6 6' 62 242% 21' 26 1.5 102% REMARKS: VFD SET AT 38 PSI DIF. AT PUMP Page 212 BTC SERVICES WATER TERMINAL TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/27/2007 SYSTEM: FCU GROUND LEVEL TECH: KC CHILLED WATER FLOW REQUIRED TEST 1 FINAL STATION METER SIZE PD GPM PD GPM % PD I GPM I.SET PT % AG2-01 N/A N/A 4.3 N/A N/A 0% NO CIRCUIT SETTER 0% AG2-02 B+G 3/4S 5.6 20' 10.2 182% 33' 15.9 126.0 105% AG2-03 N/A N/A 3.3 N/A N/A 0% NO CIRCUIT SETTER 0% AG2-04 B+G 3/4S 4.3 13' 8.25 192% 32' 4.2 34.0 98% AG2-05 B+G 3/4S 4.3 11' 7.5 174% 33' 4.6 32.0 107% AG2-06 B+G 3/4S 3.3 13' 8.25 250% 40' 3.6 40.0 109% AG2-07 N/A N/A 0.9 N/A N/A 0% NO CIRCUIT SETTER 0% BG2-01 N/A N/A 5.6 N/A N/A 0% NO CIRCUIT SETTER 0% BG2-02 N/A N/A 1.5 N/A N/A 0% NO CIRCUIT SETTER 0% BG2-03 N/A N/A 1.5 N/A N/A 0% NO CIRCUIT SETTER 0% BG2-04 N/A N/A 0.9 N/A N/A 0% NO CIRCUIT SETTER 0% BG2-05 N/A N/A 0.9 N/A N/A 0% NO CIRCUIT SETTER 0% DG2-01 N/A N/A 0.9 N/A N/A 0% NO CIRCUIT SETTER 0% AG1-01 B+G 1/2S 3.3 4' 2.5 76% 7' 3.2 0.0 97% AG1-02 B+G 1/2S 3.3 13' 4.2 127% 20' 3.3 14.0 100% AG1-03 B+G 1/2S 3.3 16' 4.6 139% 22' 3.4 14.0 103% AG1-04 B+G 1/2S 3.3 13' 4.2 127% 15 3.6 10.0 109% AG1-05 B+G 1/2S 3.3 14' 4.4 133% 24' 3.2 16.0 97% AG1-06 B+G 1/2S 4.3 14' 4.4 102% 14.8' 4.5 0.0 105% AG1-07 B+G 1/2S 4.3 17' 4.8 112% 21' 4.5 9.0 105% AG1-08 B+G 1/2S 4.3 16' 4.5 105% 16' 4.5 0.0 105% AG1-09 B+G 1/2S 4.3 16' 4.5 105% 16' 4.5 0.0 105% AG1-10 B+G 1/2S 4.3 20' 5.2 121% 32' 4.2 14.0 98% AG1-11 B+G 1/2S 4.3 18' 5 116% 21' 4.2 10.0 98% AG1-12 TA 1/2" 5.6 9' 6 107% 19' 5.6 3.2 100% AG1-13 B+G 3/4S 5.6 14' 7 125% 24' 5.5 22.0 98% AG1-14 B+G 1/2"S 3.3 17' 4.6 139% 26' 3.4 16.0 103% AG1-15 B+G 1/2"S 3.3 14' 4.4 133% 19' 3.4 12.0 103% BG1-01 B+G 1/2S 3.3 29' 6.5 197% 56' 3.4 22.0 103% BG1-02 B+G 1/25 1.5 15' 4.5 300% 40' 1.6 32.0 107% BG1-03 B+G 1/2S 1.5 17' 4.6 307% 40' 1.6 32.0 107% BG1-04 B+G 1/2S 3.3 16' 4.5 136% 25' 3.3 16.0 100% BG1-05 B+G 1/2S 0.9 17' 4.6 511% 45' 0.9 40.0 100% BG1-06 B+G 1/2S 3.3 20' 5.1 155% 31' 3.3 18.0 100% BG1-07 B+G 1/2S 3.3 15' 4.5 136% 26' 3.4 16.0 103% BG1-08 B+G 1/2S 3.3 20' 5.1 155% 30' 3.2 18.0 97% BG1-09 B+G 1/2S 3.3 16' 4.5 136% 25' 3.3 16.0 100% BGl-10 B+G 1/2S 1.5 21' 5.1 340% 38' 1.5 32.0 100% BG1-11 B+G 1/2S 0.9 25' 5.8 644% 60' 1 40.0 111% BG1-12 B+G 1/2S 0.9 25' 5.8 644% 55' 1 40.0 111% BG1-13 n/a n/a 1.5 n/a n/a 0% NO CIRCUIT SETTER 0% BG1-14 6+G 1/2S 3.8 21' 5.25 138% 27' 3.8 14.0 100% CG1-01 B+G 1/2S 1.5 12' 3.8 253% 27' 1.45 30.0 97% CG1-02 B+G 3/4S 5.6 14' 8.5 152% 20' 5.75 20.0 103% CG1-03 B+G 1/2S 0.9 14' 4.4 489% 40' 0.85 40.0 94% DG1-01 TA 1/2" 4.3 40' 4.2 98% 40' 4.2 2.5 98% DG1-02 B+G 1/2S 4.3 23' 5.5 128% 35' 4.3 14.0 100% DG1-03 N/A N/A 0.9 N/A N/A 0% NO CIRCUIT SETTER 0% REMARKS: VFD IS SET AT 38 PSI Page 213 BTC SERVICES WATER TERMINAL TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/27/2007 SYSTEM: FCU LEVEL 1 TECH: KC CHILLED WATER FLOW REQUIRED TEST 1 FINAL STATION METER SIZE PD GPM PD GPM % PD GPM SET PT % Al-01 B+G 1/2S 3.3 18' 5 152% 30' 3.6 16.0 109% A1-02 B+G 3/4S 5.6 14' 0.5 9% 34' 5.3 20.0 95% A1-03 B+G 3/4S 5.6 12' 8 143% 20' 5.7 20.0 102% Al-04 B+G 3/4S 5.6 15' 8.6 154% 40' 5.5 30.0 98% A1-05 B+G 3/4S 5.6 15' 8.6 154% 38' 5.4 30.0 96% A1-06 B+G 3/4S 5.6 10.6' 7.4 132% 17' 5.4 20.0 96% A1-07 B+G 3/4S 5.6 11' 7.5 134% 23' 5.75 22.0 103% Al-08 B+G 3.3 0% DOOR LOCKED 0% A1-09 B+G 3/4S 3.3 10.1' 7.2 218% 32' 3.2 40.0 97% A1-10 B+G 1/2S 3.3 20' 5.25 159% 39' 3.3 20.0 100% Al-11 B+G 1/2S 3.3 20' 5.25 159% 40' 3.3 20.0 100% B1-01 B+G 3/4S 8.1 4' 2.5 31% 10' 7.3 0.0 90% B1-02 B+G 3/4S 8.1 14' 8.5 105% 30' 7.3 18.0 90% B1-03 B+G 3/4S 8.1 15' 9 111% 24' 8 14.0 99% B1-04 B+G 3/4S 8.1 14' 8.6 106% 18' 8.2 10.0 101% B1-05 B+G 3/4S 8.1 15' 9 111% 28' 8 16.0 99% B1-06 B+G 1/2S 3.3 12' 4 121% 51 3.3 22.0 100% B1-07 B+G N/A 2.8 N/A N/A 0% NO CIRCUIT SETTER 0% C1-01 B+G 1/2S 1.5 21' 5.5 367% 36' 1.5 32.0 100% C1-02 B+G 3/4S 8.1 11' 7.6 94% 11' 7.6 0.0 94% C1-03 B+G 3/4S 5.6 9' 7 125% 19' 5.6 20.0 100% C1-04 NOT USED C1-05 B+G 1/2S 3.3 17' 4.8 145% 30' 3.3 18.0 100% 01-06 B+G 1/2S 1.5 20' 5.25 350% 29' 1.5 30.0 100% C1-07 B+G 3/4S 5.6 14' 8.5 152% 27' 5.75 24.0 103% D1-01 B+G 1/2S 3.3 20' 5.25 159% 30' 3.2 18.0 97% D1-02 B+G 1/2S 3.3 21' 5.25 159% 32' 3.3 18.0 100% D1-03 B+G 1/2S 5.6 20' 5.1 91% 20' 5.1 OPEN 91% D1-04 N/A N/A 1.5 N/A N/A 0% NO CIRCUIT SETTER 0% D1-05 B+G 3/4S 5.6 1.5' 2.8 50% BACKWARDS 0% D1-06 B+G 1/2S 3.3 17' 4.8 145% 38' 3.1 20.0 94% D1-07 B+G 3/4S 5.6 16' 9.25 165% 38' 5.5 30.0 98% D1-08 B+G 3/4S 5.6 15' 9 161% 35' 5.6 28.0 100% D1-09 B+G 3/4S 5.6 28' 12 214% 40' 5.6 30.0 100% D1-10 N/A N/A 3.3 N/A N/A 0% NO CIRCUIT SETTER 0% D1-11 N/A N/A 3.3 N/A N/A 0% NO CIRCUIT SETTER 0% D1-12 N/A N/A 3.8 _ N/A N/A 0% NO CIRCUIT SETTER 0% REMARKS: Page 214 BTC SERVICES WATER TERMINAL TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/27/2007 SYSTEM: FCU LEVEL 2 TECH: KC CHILLED WATER FLOW REQUIRED TEST 1 FINAL STATION METER SIZE PD GPM PD GPM % PD GPM SET PT C2-14 B+G 1/2S 3.3 8' 3.3 100% 8' 3.3 0.0 100% C2-15 B+G 1/2S 3.3 7.5' 3.2 97% 7.5' 3.2 OPEN 97% C2-16 B+G 1/2S 3.3 8' 3.3 100% 8' 3.3 0.0 100% C2-17 N/A N/A 3.3 N/A N/A 0% NO ACCESS 0% C2-18 N/A N/A 3.3 N/A N/A 0% NO ACCESS 0% D2-08 B+G 3/4S 5.6 8' 6 107% 10' 5.6 12.0 100% D2-09 B+G 3/4S 5.6 9' 6.9 123% 15' 5.5 18.0 98% D2-10 B+G 3/4S 5.6 8' 6 107% 10' 5.6 12.0 100% D2-11 B+G 3/4S 5.6 10' 7.3 130% 18 5.4 20.0 96% D2-12 B+G 3/4S 5.6 12' 8 143% 22' 5.6 22.0 100% D2-13 B+G 3/4S 5.6 12' 8 143% 20' 5.4 22.0 96% REMARKS: Page 215 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-10 TECH: KC PLAN commissary KITCHEN HOOD EXHAUST SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % KITCHEN broiler HOOD 144x3" 144x3.1" 3.10 4026 1299 1302 100% 1302 4036 100% KITCHEN kettle HOOD 155x3" 155x3.1" 3.30 3848 1166 1330 114% 1282 4231 110% KITCHEN fry HOOD 1440" 144x3.1" 3.10 3562 1149 1393 121% 1155 3581 101% KITCHEN oven HOOD 155x3" 155x3.1" 3.30 3848 1166 1307 112% 1267 4181 109% REMARKS: Page 216 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/08/07 SYSTEM: MAU-3 TECH: kc AREA: LOWER HOTEL KITCHEN SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM G130.01 3-1 6" 1.00 80 80 145 181% 75 75 94% G130.01 3-2 8" 1.00 160 160 260 163% 165 165 103% G130 3-3 10" 1.00 450 450 320 71% 420 420 93% G130 3-4 10" 1.00 450 450 320 71% 410 410 91% G130 3-5 10' 1.00 450 450 340 76% 430 430 96% G130 3-6 10" 1.00 450 450 340 76% 420 420 93% G130 3-7 10' 1.00 450 450 410 91% 420 420 93% G130 3-8 8" 1.00 400 400 445 111% 395 395 99% G130 3-9 8" 1.00 400 400 150 38% 425 425 106% G130 3-10 8' 1.00 150 150 240 160% 140 140 93% G130 3-11 HOOD 13.00 3200 246 232 94% 225 2925 91% G130 3-12 HOOD 13.50 3080 228 228 100% 210 2835 92% G130 3-13 HOOD 13.00 2850 219 162 74% 205 2665 94% G130 3-14 HOOD 13.50 3080 228 191 84% 205 2768 90% G139 3-15 8' 1.00 250 250 340, 136% 260 260 104% G139 3-16 8' 1.00 250 250 300 120% 240 240 96% G139 3-17 8' 1.00 250 250 360 144% 240 240 96% G139 3-18 8' 1.00 250 250 340 136% 255 255 102% REMARKS: Page 217 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12/18/2007 SYSTEM: EF-6 TECH: AREA: HOTEL KITCHEN GREASE EX FAN DATA DESIGN ACTUAL MAKE COOK FAN RPM N/A 1010 MODEL 330CPSA TOTAL DESIGN CFM 16,000 16,028 ESP 2.0" 2.30 "RISE TOTAL OUTLET CFM 15,284 16028 SERIAL NUMBER 1825902212-1701 MOTOR DATA MOTOR RELIANT ELECT HP 15 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 37/18.5 FRAME ACTUAL VOLTS 485,482,481 TYPE P ACTUAL AMPS 11.6,10.8,11.2 SERIAL STARTER DATA STARTER CUTTLER HAMM MODEL SIZE 2 CLASS THERMALS H2013B RATING 18.7 INSTALLED 3 THERMALS RATING REQUIRED DRIVE DATA DRIVER 2TB62 X P1 SHEAVE x BORE 1 5/8 DRIVEN 2BK114 SHEAVE x BORE 1 15/16 BELTS BX80 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE IN OUT FAN -2.20 "S.P. 0.1 "S.P. I 2.30 I"RISE REMARKS: Page 218 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: MAU-3 TECH: KC AREA: LOWER HOTEL KITCHEN FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 1650 MODEL XTI-072X114- TOTAL DESIGN CFM 17800 16954 SIZE HAMA046A ESP 2 2.03 "RISE O.S.A. CFM 17800 SERIAL NUMBER ACRMXTO175 TOTAL OUTLET CFM MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 486,487,486 ACTUAL AMPS 16.1,16.8,16.0 STARTER DATA STARTER SQUARE D MODEL SIZE CLASS THERMALS ADJUSTABLE 23-32 RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B 64 SDS SHEAVE x BORE 1 5/8 DRIVEN 2B 70 SK SHEAVE x BORE 2 7/16 BELTS BX63 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -0.77 "S.P. -0.9 "S.P. -0.13 "DROP HEAT COIL -0.90 "S.P. -1.06 "S.P. -0.16 "DROP COOL COIL -1.06 "S.P. -1.25 "S.P. -0.19 "DROP FAN -1.25 "S.P. _ 0.78_"S.P. 2.03 "RISE REMARKS: COIL VELGRID, SIZE;100"X 55"= 38.1'SQ X 445 FPM= 16954 CFM Page 219 BTC SERVICES AIR HANDLING UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/18/2007 SYSTEM: MAU-4 TECH: KC AREA: UPPER HOTEL KITCHEN FAN DATA DESIGN ACTUAL MAKE YORK FAN RPM N/A 1400 MODEL XTI-084X102- TOTAL DESIGN CFM 19530 18317 SIZE HAMA046A ESP 2 2.30 "RISE SERIAL NUMBER ACRMXTO176 O.S.A. CFM 19530 18317 TOTAL OUTLET CFM 17780 16957 MOTOR DATA MOTOR BALDOR HP 20 NAMEPLATE SPEED 1760 PHASE 3 NAMEPLATE VOLTS 230/460 SF 1.15 NAMEPLATE AMPS 50/25 FRAME 256T ACTUAL VOLTS 486,488,487 ACTUAL AMPS 17,18,18 STARTER DATA STARTER SQUARED MODEL SIZE CLASS THERMALS ADJUSTABLE 23-32 RATING SET AT 25 INSTALLED THERMALS RATING REQUIRED DRIVE DATA DRIVER 2B 52 SDS SHEAVE x BORE 1 5/8 DRIVEN 2B 68 SF SHEAVE x BORE 2 11/16 BELTS BX112 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE STATIC PRESSURE IN OUT FILTER -1.03 "S.P. 0 "S.P. 1.03 "DROP HEAT COIL 0.00 "S.P. -1.28 "S.P. -1.28 "DROP COOL COIL -1.28 "S.P. -1.46 "S.P. -0.18 "DROP FAN -1.46 "S.P. 0.84 "S.P. 2.30 "RISE REMARKS: COIL VELGRID, SIZE;69 X 90"=43.1'SQ X 425 FPM= 18317 CFM Page 220 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 11/08/07 SYSTEM: MAU-4 TECH: kc AREA: UPPER HOTEL KITCHEN SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM P130 4-1 a HOOD 109x20" 1.00 2230 2230 3140 141% 2160 2160 97% P130 4-1 b HOOD 109x20" 1.00 2230 2230 3055 137% 2190 2190 98% P130 4-2a 44/34 14x24" 2.33 6000 2575 2250 87% 2380 5545 92% P130 4-2b 44/34 12x12" 1.00 2500 2500 2250 90% 2360 2360 94% P130 4-3 HOOD 174x20" 1.00 3420 3420 3380 99% 3320 3320 97% P130.02 FCU-B1-01 12" 12" 0.79 700 892 1340 150% 880 691 99% P130.02 FCU-B1-02 12" 12" 0.79 700 892 1260 141% 880 691 99% REMARKS: Page 221 BTC SERVICES FAN UNIT TEST REPORT PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 12-13-07 SYSTEM: TECH: KC AREA: KITCHEN GREASE EXHAUST FAN DATA DESIGN ACTUAL MAKE GAYLORD FAN RPM 1732 MODEL RSPC2ESP- TOTAL DESIGN CFM 9,863 10456 MODEL 3X2500DWDO ESP 5.0" 5.50 SERIAL NUMBER GI0407050- TOTAL OUTLET CFM 9,863 10066 SERIAL NUMBER 88714 MOTOR DATA MOTOR BALDOR HP 15 NAMEPLATE SPEEC 1755 PHASE 3 NAMEPLATE VOLTS 200 SF 1.15 NAMEPLATE AMPS 44 FRAME 254T ACTUAL VOLTS 207, 207, 207 TYPE ACTUAL AMPS 39.5,39.2,39.5 SERIAL DRIVE DATA DRIVER 2B80 SHEAVE x BORE 1 5/8 DRIVEN 2B74 Q1 SHEAVE x BORE 1 15/16 BELTS BX67 SIZE x QUANTITY 2 SHEAVE CENTERLINE DISTANCE Page 222 BTC SERVICES AIR BALANCE DATA PROJECT: THE ARRABELLE AT VAIL SQUARE DATE: 10/29/07 SYSTEM: EF-10 TECH: KC PLAN KITCHEN FLOOR 1 SIZE REQUIRED TEST 1 FINAL ROOM OPENING PLAN SITE AK CFM FPM FPM % FPM CFM % KITCHEN HOOD 210 X4" 210X4" 5.83 5588 958 873 91% 960 5597 100% KITCHEN HOOD 50 X 36 171x3" 3.50 4275 1221 1067 0% 1277 4470 105% TOTAL DUCT 48X20 48X20"1 6.66 1 98631 14811 12701 0%1 1570 104561 106% REMARKS: Page 223