Loading...
HomeMy WebLinkAboutB05-0016 Plans (volume 2 mechanical M001-M111.D pages 51-100)PLUMBING LEGEND (Not oil symbols listed below ore used on these drowings) ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION CW — F — DOMESTIC COLD WATER PIPING Soo (D SURFACE CLEANOUT - HW FIRE SPRINKLER PIPING DOMESTIC HOT WATER PIPING FCO Q FLOOR CLEANOUT — - - — HWC — - - - — DOMESTIC HOT WATER CIRC. PIPING WCO 0-11 WALL CLEANOUT C -SW - - —SW- SOFTENED DOMESTIC COLD WATER PIPING COT 0 CLEANOUT TEE H -SW - - - -SW- SOFTENED DOMESTIC HOT WATER PIPING LCO PIV LINE CLEANOUT 140' HW - - - - 140 - DOMESTIC HOT WATER PIPING O TEMPERATURE SHOWN FIRE HOSE CABINET oc FIXTURE OR DRAIN P -TRAP V ----- - - - - -- VENT PIPING AD ® AREA DRAIN AV — AV — ACID RESISTANT VENT PIPING FO ® FLOOR DRAIN (ROUND GRATE) W — W — WASTE PIPING (ABOVE FLOOR IN BUILDING) FS ® FLOOR SINK (SQUARE GRATE) W -- W -- WASTE PIPING (BELOW FLOOR iN BUILDING) RD /OD Q ROOF DRAIN OR OVERFLOW DRAIN AW — AW -- ACID RESISTANT WASTE PIPING (ABOVE FLOOR IN BUILDING) — 4 GATE VALVE GAS PRESSURE REDUCING VALVE AW - AW -- ACiD RESISTANT WASTE PIPING (BELOW FLOOR IN BUILDING) VB _J _ ATMOSPHERIC VACUUM BREAKER GD — GO — GREASE DRAIN (WASTE LINE TO GREASE INTERCEPTOR) RPBFP --fir -- REDUCED PRESSURE BACKFLOW PREiIENTER IW IW INDIRECT WASTE PIPING SFP - 'v--TV-- DOUBLE CHECK BACKFLOW PREVENTER S -- S -- SANITARY SEWER PIPING (OUTSIDE BUILDING) SA BY SHOCK ARRESTOR W/ISOL.ATION VALVE ST -- ST -- STORM SEWER PIPING (BELOW GRADE OUTSIDE BUILDING) GC CV GAS SHUT -OFF VALVE —�— SSID -- SSD -- SUB- SURFACE DRAIN PIPING DAD HTJi STOP AND DRAIN VALVE SD SD STORM DRAIN PIPING (ABOVE FLOOR IN BUILDING) WH +}-- WALL HYDRANT SD - SO -- STORM DRAIN PIPING (BELOW FLOOR IN BUILDING) HB } - HOSE 8188 OD OD — OVERFLOW DRAIN PIPING (ABOVE FLOOR IN BUILDING) YH T P/r YARD HYDRANT OD -- OD -- OVERFLOW DRAIN PIPING (BELOW FLOOR IN BUILDING) MH PNEUMATIC- ELECTRIC CONTROL SWITCH MANHOLE A A — COMPRESSED AIR CI TEMPERATURE SENSOR CAST IRON G G NATURAL GAS PIPING VCP ELECTRICAL CONTRACTOR VITRIFIED CLAY PIPE *FIT FLEXIBLE PiPE CONNECTOR TCC CB TEMPERATURE CONTROL CONTRACTOR CATCH BASIN []T ST THERMOMETER KEC VTR KITCHEN EQUIPMENT CONTRACTOR VENT THRO ROOF �- PRESSURE GAUGE C IE COMMON INVERT ELEVATION --y - SIGHT GLASS NC PVC NORMALLY CLOSED POLYVINYL CHLORIDE ;` ; ; CEILING ACCESS PANEL NO R NORMALLY OPEN RSV —�-- PUMP D DUCT DROP TB FIPF PPnTFC.TION I F rF_N_n • • • (Not oil symbols listed below ore used on these drowings) — ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION F — F — FIRE SERVICE PIPING SEE DUCT TAKE —OFF DETAIL 90' TEE (RECTANGULAR) ♦ NEW SPRINKLER HEAD FS — FS — FIRE SPRINKLER PIPING 90 Et9 O EXISTING SPRINKLER HEAD WSP — WSP — WET STANDPIPE a RELOCATED SPRINKLER HEAD — HTWS — —IMF— O.S. &Y GATE VALVE W/TAMPER SWITCH HIGH TEMPERATURE HOT WATER RETURN PIPING D SIDEWALL SPRINKLER HEAD FS �— FLOW SWITCH SHEET RISER IS DRAWN ON D24 DRY SPRINKLER HEAD (SHAFT) PIV —Ill — POST INDICATOR VALVE FHC EQUIPMENT UNIT IDENTIFICATION FIRE HOSE CABINET —� FH i�i FIRE HYDRANT FVC EQUIPMENT UNIT NUMBER FIRE VALVE CABINET FDC < FIRE DEPARTMENT CONNECTION A/S DIFFUSER IDENTIFICATION DIFFUSER NECK DIAMETER DIFFUSER CFM AUTOMATIC FIRE SPRINKLER —04 - PRESSURE REDUCING VALVE CONDENSER WATER RETURN PIPING PTRV 1 PRESSURE AND /OR TEMPERATURE RELIEF VALVE FAN COIL UNIT DESIGNATION EQUIPMENT TYPE FCU 1 -0 AREA DESIGNATION (A,B,C, OR D) UNIT NUMBER LEVEL NUMBER (G2,G1,1,2,3,4,5,6 OR 7) ,A MECHANICAL GENERAL NOTES: 1. ALL NATURAL GAS PRESSURE REGULATORS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 2. INDEPENDENTLY VENT ALL PRESSURE REGULATORS REQUIRING VENTS OUTSIDE THE BUILDING. TH( REGULATORS EQUIPPED AND LABELED FOR UTILIZATION WITH VENT LIMITING DEVICES INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS DO NOT NEED VENT PIPING. 3. ALL DUCTS PENETRATING FIRE PARTITION WALLS SEPARATING THE CONDOMINIUMS /HOTEL ROOMS i CORRIDORS SHALL BE CONSTRUCTED OF STEEL NO LESS THAN 0.019 INCH THICK. PLUMBING GENERAL NOTES: 1. NO AIR ADMITTANCE VALVES SHALL BE USED ON THE PROJECT. DELETE ALL REFERENCE TO THE VALVES ON THE PLANS. 2. INDIVIDUAL AND BRANCH VENTS WITH A DEVELOPED LENGTH MORE THAN 40 FEET SHALL BE INCREASED ONE PIPE SIZE. 3. PROVIDE A CLEANOUT AT THE FOOT VENT OF ALL ISLAND VENTING SYSTEMS. 4. INDIRECT WASTES FROM BOILER RELIEF VALVES SHALL TERMINATE AT A FLOOR SINK WITH AN AIR G AS REQUIRED BY THE INTERNATIONAL PLUMBING CODE. 5. BRANCH PIPING TO FLOOR SINKS THAT RECEIVE DISCHARGE FROM BOILER RELIEF VALVES SHALL BE DUCTILE CAST IRON. Cotor, Ruma & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- MLI.DWG - M001 PLOT DATE: 04/25/2005 @ 4:49pm REV: 03/23/2005 CAD: marlane XREF: tb.dwg TB - A.DWG GENERAL LEGEND (Not oil symbols listed below are used on these drowings) ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION HWS - -- HWS -- SECTION DESIGNATION SEE DUCT TAKE —OFF DETAIL 90' TEE (RECTANGULAR) 3"M CAP ENO OF PIPE HWR A( X SECTION DRAWN ON THIS SHEET 90 Et9 XX PITCH DOWN IN DIRECTION OF ARROW HTWS X.X SECTION CUT ON THiS SHEET -X — PIPE ANCHOR — HTWS — X RISER DIAGRAM NUMBER HIGH TEMPERATURE HOT WATER RETURN PIPING 48F12 PiPE ALIGNMENT GUIDE = GINS Y -X SHEET RISER IS DRAWN ON UNION OR FLANGE —Ill — -- CWR -- UNIT EQUIPMENT UNIT IDENTIFICATION BACKORAFT DAMPER CONCENTRIC PIPE REDUCER —0-- COOLING COIL DRAIN PAN PIPING TCD EQUIPMENT UNIT NUMBER TEMP. CONTROL DAMPER - OPPOSED BLADE ---s►— ECCENTRIC PIPE REDUCER CONDENSER WATER SUPPLY PIPING N G DIFFUSER IDENTIFICATION DIFFUSER NECK DIAMETER DIFFUSER CFM PRY —04 - PRESSURE REDUCING VALVE CONDENSER WATER RETURN PIPING PTRV 1 PRESSURE AND /OR TEMPERATURE RELIEF VALVE (E) LPS EXISTING LOW PRESSURE STEAM SUPPLY PIPING Mw PLUG VALVE (N) UPC NEW GV — 4 GATE VALVE (R) RELOCATED —MPS— MEDIUM PRESSURE STEAM SUPPLY PIPING (16# - 600) VERTICAL PIPE VALVE (F) w SPIN -IN FITTING WITH M FUTURE GLV MEDIUM PRESSURE CONDENSATE RETURN PIPING GLOBE VALVE -- DUCT FIRE DAMPER HPS POINT OF CONNECTION, NEW TO EXISTING BFV FSO BUTTERFLY VALVE COMBINATION DUCT SMOKE a FIRE DAMPER HPC —i — DIRECTION OF FLOW IN PIPE BY i* BALL VALVE PC — PC DUCTWORK. PIPING AND EQUIPMENT TO BE REMOVED CV L CHECK VALVE DIA — BBD — DIAMETER DAD - -A— SOLENOID VALVE WAD — BF — WALL ACCESS DOOR --ITM BUTTERFLY SOLENOID VALVE NIC RL NOT IN CONTRACT REFRIGERANT LIQUID PIPING -}{I HOSE END DRAIN VALVE AFF REFRIGERANT SUCTION PIPING ABOVE FINISHED FLOOR P/T T P/r PRESSURE /TEMPERATURE TAP GC REFRIGERANT HOT GAS PIPING GENERAL CONTRACTOR 9_ PNEUMATIC- ELECTRIC CONTROL SWITCH STRAINER ---} -- MC MECHANICAL CONTRACTOR TEMPERATURE SENSOR I STRAINER W/ SLOWDOWN - EC UT ELECTRICAL CONTRACTOR F &T *FIT FLEXIBLE PiPE CONNECTOR TCC TEMPERATURE CONTROL CONTRACTOR IBT []T ST THERMOMETER KEC QH KITCHEN EQUIPMENT CONTRACTOR TCV �- PRESSURE GAUGE C COMMON --y - SIGHT GLASS NC NORMALLY CLOSED C A.P. ;` ; ; CEILING ACCESS PANEL NO R NORMALLY OPEN RSV —�-- PUMP D DUCT DROP TB ----` THRUST BLOCK l 1 %1 A n rnr ►11'1 nv/AC LGVGI (Not oil symbols listed below ore used on these drowings) ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION HWS - -- HWS -- HEATING WATER SUPPLY PIPING SEE DUCT TAKE —OFF DETAIL 90' TEE (RECTANGULAR) 3"M SUPPLY DUCT UP / SUPPLY DUCT DOWN HWR -- HWR -- HEATING WATER RETURN PIPING 90 Et9 pu RETURN/EXHAUST DUCT UP / RETURN/EXHAUST DUCT DOWN HTWS 45 ELB HIGH TEMPERATURE HOT WATER SUPPLY PIPING 579 9:D ROUND DUCT UP / ROUND DUCT DOWN — HTWS — HTWR - -HTWR -- HIGH TEMPERATURE HOT WATER RETURN PIPING 48F12 EEED INDICATES FLAT OVAL DUCTWORK GINS — CWS — CHILLED WATER SUPPLY PIPING FLEXIBLE DUCT CONNECTION CWR -- CWR -- CHILLED WATER RETURN PIPING BDD BACKORAFT DAMPER 0 D COOLING COIL DRAIN PAN PIPING TCD ® TEMP. CONTROL DAMPER - OPPOSED BLADE C C — CONDENSER WATER SUPPLY PIPING TCO ® TEMP. CONTROL DAMPER- PARALLEL BLADE CR - CR -- CONDENSER WATER RETURN PIPING 1 LOUVER WITH SCREEN LPS — UP — LOW PRESSURE STEAM SUPPLY PIPING Mw � MANUAL VOLUME DAMPER UPC -- LPC -- LOW PRESSURE CONDENSATE RETURN PIPING MOTOR OPERATED DAMPER MPS —MPS— MEDIUM PRESSURE STEAM SUPPLY PIPING (16# - 600) LED w SPIN -IN FITTING WITH M MPC -- MPC -- MEDIUM PRESSURE CONDENSATE RETURN PIPING FD 4 DUCT FIRE DAMPER HPS — HPS — HIGH STEAM SUPPLY PIPING FSO ® COMBINATION DUCT SMOKE a FIRE DAMPER HPC -- HPC -- HIGH PRESSURE CONDENSATE RETURN PIPING SD 0 DUCT SMOKE DAMPER PC — PC PUMPED CONDENSATE PIPING 1� DUCT SMOKE DETECTOR BBD — BBD — BOILER SLOWDOWN PIPING DAD ;' ; ; DUCT ACCESS DOOR BF — BF — BOILER FEED WATER PIPING TURNING VANES IN DUCT ELBOW RL — RL — REFRIGERANT LIQUID PIPING RS -- RS -- REFRIGERANT SUCTION PIPING EP ELECTRIC - PNEUMATIC CONTROL VALVE RHG — RHG — REFRIGERANT HOT GAS PIPING PE 9_ PNEUMATIC- ELECTRIC CONTROL SWITCH ® TEMPERATURE SENSOR TT ®Ti THERMOSTATIC STEAM TRAP UT WALL MOUNTED THERMOSTAT F &T *FIT FLOAT AND THERMOSTATIC STEAM TRAP UNIT MOUNTED THERMOSTAT IBT []T ST INVERTED BUCKET STEAM TRAP QH HUMIDISTAT - TCV - A W-- (2 OR 3 -WAY) TEMPERATURE CONTROL VALVE UNDERCUT DOOR --y - VENTURI METER LOUVER —�— CALIBRATED BALANCING VALVE R DUCT RISE RSV -- REFRIGERANT SERVICE VALVE D DUCT DROP OPS DIFFERENTAL PRESSURE SWITCH A.L. ACOUSTICALLY LINED DUCTWORK —®— MAY MANUAL AIR VENT TCOAD TEMPERATURE CONTROL OUTSIDE AIR DAMPER AAV AUTOMATIC AIR VENT TCRAD TEMPERATURE CONTROL RETURN AIR DAMPER FS FLOW SWITCH TCEAD TEMPERATURE CONTROL. EXHAUST AIR DAMPER EJ EXPANSION JOINT SP iN WC STATIC PRESSURE IN INCHES WATER COLUMN BJ ---� }— BALL JOINT EXPANSION COMPENSATOR SD Q SUPPLY AIR DEVICE CWS CWR/HWS HOUR _ SUPPLY & RETURN BRANCH PIPING TO TERMINAL UNIT RG Q RETURN/EXHAUST AIR DEVICE DOUBLE /SINGLE LINE DUCT LEGEND (Not oil symbols listed below ore used on these drowings) SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE SiNGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE 45' TEE ( R OUND) SEE DUCT TAKE —OFF DETAIL 90' TEE (RECTANGULAR) RIGID ( � W— FLEX �.. --►y FLEX DUCT 90 RADIUS EtB 45' TEE (RECTANGULAR) CONICAL TEE 9O' TEE (ROUNO) MANUAL VOLUME DAMPER 90 Et9 DUCT SPLIT `VOLUME DAMPER SPIN IN REDUCER 45 ELB I i © 2003 42140 ARCHITECTURE, INC. 1 �P� ) 1 '' �GLAS 34968 NA� V12 xz_ j "_ PRO)P,Cr N PROJECT KEYPLAN MECHANICAL LEGENDS "AL "A AIR HANDLING UNIT SCHEDULE SYSTEM MATERIAL BOILER SCHEDULE SEAL FAN DATA COIL DATA EVAPORATIVE COOLER DATA FILTER DATA SUPPLY AIR DOWNSTREAM GALVANIZED DESIG. MFR. SERVICE MODEL CFM TOTAL AT 8150' CFM O.A. AT 8150' TSP IN. W.C. AT S.L ESP IN. W.C. AT S.L. FAN WHEEL DIA. TYPE RPM MIN. HP SERVICE FACE AREA SF COIL CFM AT $150' AIR A P IN W.C. AT S.L. EAT LAT MBH GPM PROPYLENE GLYCOL % WATER IN W.C. AT S.L CELL DEPTH NET FACE AREA SF RECIRC GPM SAT. EFF. % AIR A P IN W.C. AT S.L. PUMP HP TYPE AREA SF % EFF. CONTROL REMARKS -_ F DB 7 O F WB O F DS OF WS MUA-1 TRANE WEST CONDOS T-SERIES SIZE 8 2000 2000 2.0 1.0 12" A.F. 2117 2 I HEATING NPT 2000 OF -19 - 70 - 142.6 7.1 30 0.18 21000 16800 2569 25 GORDON F18.2-G 2" 11.1 30% 160 200 30 1 1,2,4,5,6 DISHWASHER EXHAUST ALUMINUM -2" 1 NONE 1 GALVANIZED .2" C PLATT 75 STEEL 0.7 2.1 180 COOLING 1 7.5 2000 0.12 95 60 55 46 164.7 11.7 30 1.1 25 GORDON F18.2 -G 4'r 1 2 MUA-2 TRANE EAST CONDOS T-SERIES SIZE 8 2000 2000 2.0 1.0 12" A.F. 2117 2 HEATING 7.3 2000 0.03 -19 - 70 - 142.6 1. 7.1 30 0.18 4.2 55 30 TRANE 0.3 2" 11.1 30% 540 1.0 23 ROOM 65 75 14.4 1.0 0.7 180 30 BLR-3 HEATING BRYAN RW-1050 250 10500 8400 1266 is COOLING 7.5 2000 0.12 95 60 55 46 64.7 11.7 30 1.1 SA-10 ROOM LOBBY TRANE VCWF 14 MUA-3 TRANE LOWER HOTEL KITCHEN MCC SIZE 40 17800 17800 3.6 2.0" 25" A.F. 1631 20 HEATING 36.8 178001 0.07 -19 - 55 - 1055.0 55.4 30 6.4 1. PROVIDE BOILER FACTORY PIPED FOR TOP RETURN I LOW TEMPERATURE RETURN. ROOM A 2" 1 69.3 30% 2. GAS TRAIN AND BURNER SELECTIONS ARE BASED ON NATURAL GAS WITH A 1 OF 765 BTU /C.F. TT 1 30X12 1200 33.6 55 90 30 3. PROVIDE FM GAS TRAIN 0.3 T-STAT COOLING 37.8 17800 0.26 90 60 55 48 1 505.3 91.0 30 11.0 0.3 T-STAT MUA-4 TRANE UPPER HOTEL KITCHEN MCC SIZE 40 19530 19530 3.5 2.0 28 A.F. 1305 20 HEATING 36.8 19530 0.09 1 -19 - 55 - 157.6 60.8 30 7.7 0.3 0.3 T-STAT 2" 69.3 30% I 5558- TRANE TT COUPLES I0X8 200 5.6 55 90 30 I COOLING 39.3 19530 0.32 90 60 56 48 577.4 104.1 30 8.7 MUA-5 TRANE SE KITCHEN MCC SIZE 21 9000 9000 3.7 2.5 20" A.F. 1894 10 HEATING 20.8 9000 0.06 -19 - 55 - 633.4 28.0 30 0.7 2" 31.1 30% HC-12 TRANE 17 FITNESS 24x20 2200 61.6 55 90 30 4.4 0.3 T-STAT HC-13 TRANE TT TREATMENT I0X8 COOLING 20.8 9000 0.22 90 60 55 48 255.5 46.1 30 6.2 ROOM MUA-6 TRANE SE RETAIL MCC SIZE 25 11200 11200 3.9 2.6 20" A.F. 2095 15 HEATING 24.4 11200 0.08 -19 - 70 - 798.4 41.9 30 1.2 TRANE TT WOMENS I2x12 600 16.8 2" 38.9 30% 1.2 0.3 T-STAT LOCKERS COOLING 24.4 11200 0.18 90 60 70 54 181.7 32.8 30 1.3 0.3 T-STAT MUA-7 TRANE NE RETAIL MCC SIZE 25 11000 11000 3.6 2.2 20" A.F. 2040 15 HEATING 24.4 11000 0.08 -19 - 70 - 784.2 41.2 30 1.1 IA 0.3 T-STAT 2?r 31.1 30% I HC-18 TRANE TT SPA 18X12 1100 30.8 55 90 30 COOLING 24.4 110001 3200 0.17 90 60 70 54 178.5 32.2 30 1.3 MUA-8 TRANE NW RETAIL MCC SIZE 8 3200 3200 3.3 2.2 12" A.F. 2927 6 HEATING 7.5 0.11 mols -19 - 70 - 1 228.1 12.0 30 0.4 2" 11.1 30% HC-20 TRANE TT MENS 30X12 1400 39.2 55 90 30 2.8 0.3 T-STAT LOCKERS COOLING 1 7.5 3200 .15 90 60 70 54 51.9 9.4 30 0.4 TRANE TT HALLWAY 1202 600 16.8 MUA-9 TRANE BOILER ROOM MCC SIZE 57 25,000 25,000 2.6 1.2 32" A.F. 1077 20 HEATING 57.0 25000 0.07 -19 - 70 - 1782.2 93.6 30 3.3 1 2" 96.7 30% VFD ON SUPPLY FAN I 12" so 90% 0.3 1 112 COOLING MUA-10 NOT USED 2' 30% AHU -1 TRANE SPA MCC SIZE 25 11000 11000 4.7 3.0 20" A.F. 2194 16 HEATING 24.4 11000 0.07 -19 959.2 51.0 30 1.4 2" 38.9 30% 8" 22 71% 0.3 112 COOLING 24.4 11000 0.23 90 60 1 55 48 3123 56.3 30 7.3 AHU-2 TRANE BALLROOM MCC SIZE 35 15000 15000 4.9 3.6 25" A.F. 1694 20 HEATING 34.1 15000 0.06 -19 - 55 - 1922.8 48.5 30 1.4 2" 1 61.3 30% VFD ON SUPPLY FAN 1 COOLING1 32.8 16000 0.24 90 60 55 48 425.8 76.7 30 7.1 AHU-3 TRANE GREAT ROOM MCC SIZE 12 5000 1500 2.9 1.5 15" A.F. 2295 7.5 HEATING 12.3 5000 0.08 1 25 - 110 - 316.4 16.6 30 1.1 2" 16.7 30% T: LING COO 12.3 r 5000 018 90 1 60 1 55 48 14 1.9 25.6 30 i 4.7 OTES: MAKEUP AIR UNITS SERVING KITCHEN SPACES SHALL PROVIDE AIRFLOW EQUAL TO THE AMOUNT EXHAUSTED. CHILLED WATER EWT- LWT-57F, HEATING WATER EWTt18OF1LWT=I4OF PROVIDE SINGLE POINT ELECTRICAL CONNECTION ON ALL MUMS AND AHU'S S855-2 RAt DUCTWORK CLASSIFICATION SCHEDULE SYSTEM MATERIAL BOILER SCHEDULE SEAL INSULATION AREA SQUARE FEET CLASS CLASS REMARKS SUPPLY AIR DOWNSTREAM GALVANIZED +3## B I" LINER MBH MBH HEATING BURNER 1,2,5 OUTSIDE AIR BETWEEN MAU OR GAS TRAIN 2" C 2" WRAF AHU AND LOUVER OPERATING 28,394 DESIG. SERVICE MFR. MODEL BOILER INPUT OUTPUT SURFACE EWT LWT PROPYLENE WEIGHT REMARKS SLOWER MFG MODEL SIZE STD. PRESS. PSI MIN. MAX. I" LINER ISO STEEL 55 HP AT S. L. AT 8150' SO. FT. HP C I" LINER WITHIN 15' OF FAN NPT OF OF GLYCOL LBS GARAGE EXHAUST BLR-1 HEATING BRYAN RW2100 Soo 21000 16800 2569 25 GORDON F18.2-G 4" 1 2 160 200 30 36,770 1,2,4,5,6 DISHWASHER EXHAUST ALUMINUM -2" A NONE ALL OTHER EXHAUST SYSTEMS GALVANIZED .2" C PLATT 75 STEEL 0.7 2.1 180 ACID ROOM EXHAUST SCH 40 -2" C BLR-2 HEATING BRYAN RW-2100 Soo 21000 16800 2569 25 GORDON F18.2 -G 4'r 1 2 160 200 30 36,770 1,2,4,5,6 ROOM BALLROOM TRANE VCWF I 3600 I 1080 1.0 PLATT 31 55 HC-4 TRANE I TREATMENT I0X8 150 4.2 55 SUMMER 30 TRANE 0.3 0.3 T-STAT 900 540 1.0 23 ROOM 65 75 14.4 1.0 0.7 180 30 BLR-3 HEATING BRYAN RW-1050 250 10500 8400 1266 is GORDON 516.1-G 21/2" 1 2 160 200 30 22,895 1,2,3,4,5,6 30 SA-10 ROOM LOBBY TRANE VCWF 14 2500 PLATT 750 1.0 26 30 55 HC-6 TRANE TT TREATMENT NOTES: 150 4.2 55 90 30 0.3 0.3 T-STAT 1. PROVIDE BOILER FACTORY PIPED FOR TOP RETURN I LOW TEMPERATURE RETURN. ROOM A 2. GAS TRAIN AND BURNER SELECTIONS ARE BASED ON NATURAL GAS WITH A HIGHER HEATING VALUE OF 765 BTU /C.F. TT LOUNGE 30X12 1200 33.6 55 90 30 3. PROVIDE FM GAS TRAIN 0.3 T-STAT HC-8 TRANE TT TREATMENT lox$ 150 4.2 55 90 4. PROVIDE SINGLE POINT CONNECTION, KEYBOARD DISPLAY 0.3 0.3 T-STAT ROOM RELAYS FOR ALARM BELL: FLAME FAILURE, LOW WATER, HIGH LIMIT HC-9 TRANE TT HYDRO I0X8 DDC POINTS: REMOTE ALARM ENABLE / DISABLE 4.2 55 90 30 0.3 0.3 T-STAT THERAPY I 5558- RAt DUCTWORK CLASSIFICATION SCHEDULE SYSTEM MATERIAL PRESSURE SEAL INSULATION AREA SQUARE FEET CLASS CLASS REMARKS SUPPLY AIR DOWNSTREAM GALVANIZED +3## B I" LINER OF MAU OR AHU 59,248 88,872 2,962 1,2,5 OUTSIDE AIR BETWEEN MAU OR -STEEL GALVANIZED 2" C 2" WRAF AHU AND LOUVER STEEL 28,394 946 3,4,5 LOADING DOCK 5,479 8,219 274 I" LINER FOR RECTANGULAR DUC SUPPLY AIR FOR FCU GALVANIZED +111 C I" WRAP FOR ROUND DUCT 3. THE TRUCK YARD AND LOADING DOCK REQUIRES 29,213 CFM OF MAXIMUM VENITILATION. THESE AREAS STEEL 4. MINIMUM VENTILATION FOR THE TRUCK YARD AND DOCK IS 1220 CFM. EF-S PROVIDES MINIMUM VENTILATION VIA A VARIABLE FREQUENCY DRIVE AND OPERATES CONTINUOUSLY AT 7500 CFM. S. THE EXHAUST FANS CAN BE FOUND IN THE FAN SCHEDULE ON THIS SHEET. CONTROL SEQUENCES ARE RETURN AIR FOR FCU GALVANIZED .1" C I" LINER ISO STEEL 55 90 30 TOILET EXHAUST GALVANIZED -2" C I" LINER WITHIN 15' OF FAN 30 STEEL 1/2 ROOM MEETING ROOM GARAGE EXHAUST GALVANIZED 2" C NONE 330 STEEL 22 25 55 GREASE EXHAUST WELDED -3" A NONE 300 STEEL 55 90 30 DISHWASHER EXHAUST ALUMINUM -2" A NONE ALL OTHER EXHAUST SYSTEMS GALVANIZED .2" C NONE 75 STEEL 0.7 2.1 180 ACID ROOM EXHAUST SCH 40 -2" C NONE HC-3 PVC PIPE TT TREATMENT lox$ NOTE: 1. ALL DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR. SHEET METAL SIZES WILL BE LARGER THAN SHOWN ON PLAN FOR LINED DUCTWORK. DUCTWORK CLASSI FAM F I AU GARAGE VENTILATION CALCULATIONS DESIG. SERVICE MAX VENT MIN VENT INSIDE AREA SQUARE FEET (1.5 CFM/S.F.) (0.05 CFM/S.F.) REMARKS WATER A CFM CFM PROPYLENE GLYCOL % LOWER LEVEL PARKING 59,248 88,872 2,962 1,2,5 UPPER LEVEL PARKING 38,892 58,338 1,945 1,2,5 TRUCK YARD 18,929 28,394 946 3,4,5 LOADING DOCK 5,479 8,219 274 3,4,6 NOTES: 1. UPPER AND LOWER LEVEL PARKING REQUIRES 147,210 CFM OF MAXIMUM VENITILATION. THESE AREAS ARE SERVED BY EF-I THROUGH 4, WHICH ARE 37,000 CFM EACH, FOR A TOTAL OF 148,000 CFM 2. MINIMUM VENTILATION FOR THE PARKING AREAS IS 4907 CFM. EF-4 PROVIDES MINIMUM VENTILATION VIA A VARIABLE FREQUENCY DRIVE AND OPERATES CONTINUOUSLY AT 9300 CFM. 3. THE TRUCK YARD AND LOADING DOCK REQUIRES 29,213 CFM OF MAXIMUM VENITILATION. THESE AREAS ARE SERVED BY EF-S, WHICH PROVIDES 30,000 OF EXHAUST 4. MINIMUM VENTILATION FOR THE TRUCK YARD AND DOCK IS 1220 CFM. EF-S PROVIDES MINIMUM VENTILATION VIA A VARIABLE FREQUENCY DRIVE AND OPERATES CONTINUOUSLY AT 7500 CFM. S. THE EXHAUST FANS CAN BE FOUND IN THE FAN SCHEDULE ON THIS SHEET. CONTROL SEQUENCES ARE LOCATED IN SPECIFICATION SECTION 15975 HOT WATER DUCT HEATING COIL DESIG. SERVICE MFR. MODEL (HIGH RANGE) INSIDE CFM MAX. HEATING CFM AT 8150' MIN. PRIMARY CFM AT 8150' MIN. NLETS.P, IN W.C. AT S.L PROPYLENE WATER A AIR SUPPLY REGISTER PROPYLENE GLYCOL % DESIG. MFR. MODEL SYSTEM COIL AT MBH EAT LAT GLYCOL A P FT. GPM A P IN. CONTROL REMARKS 450 1.0 21 27 DIMENSIONS 8150' 12 DEG.F DEG.F % W.C. 24X24 W.C. TB2 MEETING ROOM HC -1 TRANE TT TREATMENT loxe ISO 4.2 55 90 30 75 0.3 0.3 T-STAT ISO 30 WHITE 1/2 ROOM MEETING ROOM TRANE VCWF 10 1100 550 330 1.0 22 25 55 HC-2 TRANE TT TREATMENT lox$ 300 8.4 55 90 30 TRANE 0.6 0.3 T-STAT 600 360 1.0 22 ROOM 55 75 9.6 0.7 2.1 180 30 SUPPLY GRILLE 272FL TS-6 PREFUNC71ON HC-3 TRANE TT TREATMENT lox$ ISO 4.2 55 90 30 75 0.3 0.3 T-STAT 180 30 K RELIABLE ROOM BALLROOM TRANE VCWF I 3600 I 1080 1.0 I 31 55 HC-4 TRANE TT TREATMENT I0X8 150 4.2 55 90 30 TRANE 0.3 0.3 T-STAT 900 540 1.0 23 ROOM 65 75 14.4 1.0 0.7 180 30 9 (2) 2" SLOT TS-8 BALLROOM HC-5 TRANE TT TREATMENT lox$ 150 4.2 55 90 30 75 0.3 0.3 T-STAT 180 30 SA-10 ROOM LOBBY TRANE VCWF 14 2500 1250 750 1.0 26 30 55 HC-6 TRANE TT TREATMENT I0X8 150 4.2 55 90 30 0.3 0.3 T-STAT ROOM HC-7 TRANE TT LOUNGE 30X12 1200 33.6 55 90 30 2.4 0.3 T-STAT HC-8 TRANE TT TREATMENT lox$ 150 4.2 55 90 30 0.3 0.3 T-STAT ROOM HC-9 TRANE TT HYDRO I0X8 150 4.2 55 90 30 0.3 0.3 T-STAT THERAPY I HC-10 TRANE TT COUPLES I0X8 200 5.6 55 90 30 I OA 0.3 T-STAT TREATMENT HC-11 TRANE TT VICHY lox$ 200 5.6 55 90 30 0.4 0.3 T-STAT ROOM HC-12 TRANE 17 FITNESS 24x20 2200 61.6 55 90 30 4.4 0.3 T-STAT HC-13 TRANE TT TREATMENT I0X8 ISO 4.2 55 90 30 0.3 0.3 T-STAT ROOM HC-14 TRANE TT OFFICE 12xI0 500 14 55 90 30 1.0 0.3 T-STAT HC-15 TRANE TT WOMENS I2x12 600 16.8 55 90 30 1.2 0.3 T-STAT LOCKERS HC-16 TRANE TT STAFF lox$ 150 4.2 55 90 30 0.3 0.3 T-STAT LOUNGE HC-17 TRANE TT NAIL I6xI2 700 19.6 55 90 30 IA 0.3 T-STAT SALON I HC-18 TRANE TT SPA 18X12 1100 30.8 55 90 30 2.2 0.3 T-STAT RETAIL HC-19 TRANE TT WOMENS 18x12 800 22.4 55 90 30 1.6 0.3 T-STAT POOL HC-20 TRANE TT MENS 30X12 1400 39.2 55 90 30 2.8 0.3 T-STAT LOCKERS HC-20 TRANE TT HALLWAY 1202 600 16.8 55 90 30 1 F1.2 0.3 T-STAT NOTES: HEATING COIL CAPACITY BASED ON 180 DEG F EWT. 30 DEG F DELTA T. S83o4 "AM TERMINAL BOX SCHEDULE A DESIG. SERVICE MFR. MODEL (HIGH RANGE) INLET DIA. (IN.) MAX. PRIMARY CFM AT 8150' MAX. HEATING CFM AT 8150' MIN. PRIMARY CFM AT 8150' MIN. NLETS.P, IN W.C. AT S.L DISCH. N.C. AT 1.0" S.P. RADIATED N.C. AT AT 1.0" S.P. A HEATING COIL DATA SUPPLY REGISTER PROPYLENE GLYCOL % CONTROL REMARKS EAT OF LAT OF MBH AT 8150' GPM AT 8150' WATER A P FT. W.C. EWT OF TB -1 MEETING ROOM TRANE VCWF 12 1500 750 450 1.0 21 27 55 75 12 0.9 0.7 180 30 24X24 SEE PLANS TB2 MEETING ROOM TRANE VCWF 10 1200 600 360 1.0 22 26 55 75 9.6 0.7 2.1 ISO 30 WHITE 1/2 TB-3 MEETING ROOM TRANE VCWF 10 1100 550 330 1.0 22 25 55 75 8.8 0.6 1.8 180 30 I SURFACE ALUMINUM TB-4 MEETING ROOM TRANE VCWF 10 1200 600 360 1.0 22 26 55 75 9.6 0.7 2.1 180 30 SUPPLY GRILLE 272FL TS-6 PREFUNC71ON TRANE VCWF 14 2500 1250 750 1.0 25 30 55 75 20 1.4 1.0 180 30 K RELIABLE TS-6 BALLROOM TRANE VCWF 16 3600 1800 1080 1.0 27 31 55 75 28.8 2.0 1.4 180 30 20 13 TB-7 BALLROOM TRANE VCWF 12 1800 900 540 1.0 23 29 65 75 14.4 1.0 0.7 180 30 9 (2) 2" SLOT TS-8 BALLROOM TRANE VCWF 12 1800 900 540 1.0 23 29 55 75 14.4 1.0 0.7 180 30 SA-10 TS-9 LOBBY TRANE VCWF 14 2500 1250 750 1.0 26 30 55 75 20 1.4 1.0 180 30 11. HEATING COIL CAPACITY BASED ON 30 DEG F DELTA T. FAS AIR DEVICE SCHEDULE DESIG. MFR. TYPE MODEL FRAME MATERIAL FINISH DAMPER TYPE FACE SIZE NECK SIZE REMARKS A TITUS SUPPLY REGISTER 2718 S& SURFACE STEEL WHITE OBD SEE PLANS LWT GLYCOL B TITUS RETURN GRILLE 23RL SURFACE STEEL WHITE OBD SEE PLANS 9 OF C TITUS SUPPLY DIFFUSER TMSA LAY-IN STEEL WHITE TRANE 24X24 SEE PLANS Soo D TITUS SUPPLY DIFFUSER TMSA-A LAY-IN ALUMINUM WHITE 18 24X24 TRANE 354.3 E TITUS RETURN GRILLE PAR LAY-IN STEEL WHITE 1/2 24X24 25.5 UH-3 F TITUS SUPPLY LINEAR ML-38 SURFACE ALUMINUM BLACK 7 (2) 3/4" SLOTS SEE PLANS T-STAT G TITUS RETURN LINEAR MLR-38 SURFACE ALUMINUM BLACK ? (2) 3/4" SLOTS SEE PLANS 1075 H TITUS EXHAUST 350FL SURFACE STEEL WHITE OBD SEE PLANS 0.15 36 I TITUS SUPPLY GRILLE 272FL SURFACE STEEL WHITE 28 SEE PLANS 24 ELBOW SILENCER i TITUS FLOWBAR FL-20-HT LINEAR 0.16 BLACK 48 (1) 2" SLOT SEE PLANS B K RELIABLE EXHAUST LFDXHD SURFACE STEEL WHITE OBD SEE PLANS SEE PLANS EF-I L TITUS RELIEF GRILLE 271RS SURFACE STEEL WHITE 18 SEE PLANS 20 13 M TITUS RETURN GRILLE 355R SURFACE STEEL WHITE 36,000 SEE PLANS 24 A N TITUS FLOWBAR FL-20-HT LINEAR 9 BLACK 9 (2) 2" SLOT SEE PLANS B REMARKS: A. NON -DUCTED S. PROVIDE INSULATED PLENUM C. DIFFUSER TO MATCH CEILING CURVE, PROVIDE HIGH THROW PATTERN CONTROLLER I S9 HOT WATER UNIT HEATER SCHEDULE DESIG. MFR. MODEL SERVICE CFM AT 8150' AIR A P IN W.C. AT S.L. HEIGHT (IN.) WIDTH (IN.) PROPYLENE INSERTION LOSS (DB) AT +2000 FPM REMARKS 63 HZ DESIG. MFR. MODEL MBH CFM GPM EWT LWT GLYCOL RPM HP CONTROL REMARKS 16 15.5 15.5 AT .L. 11 9 OF OF % 35 25 (6) REQUIRED SA2 UH-1 TRANE 60-S 27.4 Soo 3.0 ISO 160 30 1140 1/8 T-STAT 18 UH-2 TRANE 354.3 220 5500 22.6 180 160 30 1140 1/2 T-STAT 25.5 UH-3 OMARK MUHOS-41 5 K 350 28 35 25 (4) REQUIRED 1600 1/100 T-STAT 2. UH-4 TRANE 18-S 7.0 280 1.4 180 170 30 1075 1/50 T-STAT 16 NOTES: - ------ 1. REFERENCE PLANS FOR UNIT HEATER LOCATIONS 2. ELECTRIC UNIT HEATER, 460 V, 3 PHASE, UNIT MOUNTED THERMOSTAT, SERVES THE GLOCKENSPIEL S830-14 m SOUND ATTENUATOR SCHEDULE DESIG. MFR. MODEL SERVICE CFM AT 8150' AIR A P IN W.C. AT S.L. HEIGHT (IN.) WIDTH (IN.) LENGTH (IN.) INSERTION LOSS (DB) AT +2000 FPM REMARKS 63 HZ 125 HZ 250 HZ 500 HZ I OOO1HZ 2000 HZ 4000HZ 8000 HZ SA-1 COOK RCG-AT-18 EF-19, 22, 23, 24,25,29 1500 05.26.06 05.26.06 16 15.5 15.5 6 11 9 14 is 28 35 25 (6) REQUIRED SA2 COOK RGC-AT-22 EF -14, 15,16, 32 2400 16 19.5 19.5 5 11 9 14 18 28 35 26 (4) REQUIRED SA-3 COOK RGC.AT-28 EF- 17,18, 20, 21 4000 - 16 25.5 25.5 5 11 9 14 18 28 35 25 (4) REQUIRED SA-4 VISRON 24 EVRS MAU-4 19,530 0.2 48 36 60 4 10 17 30 28 26 23 16 ELBOW SILENCER SA-5 VIBRON 30EVRS MAU-5 10000 0.15 36 30 96 8 14 23 44 31 28 26 24 ELBOW SILENCER SA-6 VISRON 24EVRS MUA-6 11,200 0.16 24 48 96 6 9 20 46 30 27 24 22 ELBOW SILENCER SA-7 VIBRON 28 VRS EF-I 18,000 0.17 28 56 60 9 11 18 24 20 13 12 9 (2) REQUIRED SA-8 VISRON 24 VRS EF-2 36,000 0.16 24 96 36 5 7 12 16 9 7 9 5 SA2 VIBRON 22.5VRS EF-3 36,000 0.17 26 90 120 6 11 24 45 33 is 17 12 SA-10 AIR BALANCE AAC-86 EF-4 18,000 0.20 96 72 8 1 7 5 9 16 19 16 13 1ACOUSTICAL LOUVER (2) REQUIRED NOTES S920- OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON COLORADO ARCHITECT OF RECORD ■ ARC HI TECTURE A t Denver, Colorado MASTERPLANNER DESIGN ARCHITECT FLARTJHOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SI,IFERDESIGNS EDWARDS, COLORADO PROJECT NUMBER.- 20826.01 ISSUE REVISION DATE 023 ADDENDUM 14 07.29.05 147 ASI 126 04.10.06 148 119 PR 124R1 ASI 093 04.11.06 04.11.06 146 149 CCD 025 CCD 026 04.14.06 04.14.06 150 PR 134 04.17.06 154 PR 136 04.17.06 156 158 PR 137 CCD 029 04.24.06 04.26.06 171 173 CCD 031 ASI 144 05.10.06 05.11.06 177 183 CCD 033 CCD 033R1 05.17.06 05.26.06 189 CCD 41 05.26.06 185 191 CCD 40 ASI 159 05.26.06 05.26.06 RE. INDEX SHEETS FOR PREVIOUS ISSUE LISTINGS PRpjwr PROJECT KEYPLAN LAI kj N Cator, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P-MS1.DWG - M002-1 PLOT DATE: 05/25/2006 @3:33pm REV. 05/25/2006 CAD: hdy XREF: tb-c.dwg tb - smoke- defsubl.dwg tb.dwg tb-condo.dwg 1 1 M002.1 PUMP SCHEDULE ADDENDUM 14 07.29. DESIG. MFR. MODEL MAX. HOT WATER COI DATA TOTAL MOTOR DATA A 6 0 HZ EWT OF PROPYLENE SUCTION DISCHARGE GPM PROPYLENE DESIG. MFR. MODEL PUMP TYPE SERVICE OPER. TEMP. GPM DYNAMIC EFF. MIN. RPM GLYCOL SIZE SIZE CONTROL REMARKS 8150' MBH OF OF 308 OF SIZE HEAD FT. % HP OF % IN. IN. STAIR 8 EXPOSED 195 12.2 180 150 PRIMARY 30 3/4" FREE 1/30 120 1 900 BG1 -01 CW 03 15 CEILING PHWP4 B &G 1510 END HEATING 220 1120 A 50 72.8 25 1750 30 8 6 ELEVATOR 1 INVERTED 195 12.2 613C SUCTION WATER 30 314" FREE 1130 120 1 228 AG1 -01 CW 03 VESTIBULE EXPOSED 30 9 115 140 PRIMARY 40 24 DISCHARGE 1990 AREA C SNOW MELT CUH MODINE STAIR 6 INVERTED PHWP -2 B &G 1510 END HEATING 220 1120 50 72.8 25 1750 30 8 6 HOTEL EXPOSED AT405MHVN 449 613C SUCTION WATER 1 580 30 DISCHARGE 115 140 926 40 CUH MODINE HOTEL LOBBY INVERTED 790 64.3 180 150 PRIMARY 30 1" FREE (2) 120 1 81 -01 CW 12 VESTIBULE RECESSED PHWP -3 B &G 1510 END HEATING 220 560 50 82.5 15 1750 30 5 4 HOTEL ENTR. INVERTED 270 19.2 4BC SUCTION WATER 30 3/4" FREE 1120 120 1 B1 -02 CW 04 VESTIBULE RECESSED L -7 AIR BALANCE SECONDARY EF -37 60 DISCHARGE 4" 10.14 0.1 7200 CUH MODINE HOTEL ENTR. INVERTED SHWP4 B &G 1510 END HEATING 220 825 120 72.9 60 1750 30 8 6 VESTIBULE VARIABLE SPEED DRIVE 72 120 6G SUCTION WATER 17,800 DISCHARGE CUH MODINE REST. ENTR. INVERTED 790 64.3 180 150 SECONDARY 30 1" FREE (2) 120 1 81 -04 CW 12 VESTIBULE RECESSED SHWP -2 B &G 1510 END HEATING 220 825 120 72.9 60 1750 30 8 6 STAIR 9 VARIABLE SPEED DRIVE 195 12.2 6G SUCTION WATER 30 3/4" FREE 1/30 120 1 B1 -05 CW 03 AIR BALANCE CEILING MAU -8 48 36 4" DOM. WATER 0.1 3200 DISCHARGE CUH MODINE STAIR 7 INVERTED HWP -1 B &G 1510 END HEATER 220 343 50 76.2 10 1750 30 5 4 VESTIBULE VARIABLE SPEED DRIVE 3BC SUCTION DISH EXHAUST AIR BALANCE EL -445K DISCHARGE 12 12 4" 0.28 0.2 300 WOMENS EF-8 COOK A I DOM. WATER - 150 0.3 1500 - 47 W DIRECT CUH MODINE SKATE CONCEALED HWP -2 B &G 1510 END HEATER 220 343 A I 50 76.2 0 1750 30 4 3 A VARIABLE SPEED DRIVE EF-9 COOK 313C C SUCTION KITCHEN 600 DISCHARGE 1 1120 4937 0.25 BELT MOTORIZED - MENS 0.65 .09 480 ROOF SNOW MELT HOOD /DRYER CUH MODINE SKATE CONCEALED HWP-3 B &G 1510 END HEAT 220 940 40 82.0 20 1750 30 6 5 RESTROOM VARIABLE SPEED DRIVE EF -10 COOK 513C SUCTION EXCHANGERS 9000 DISCHARGE 1 1/20 7641 5 BELT CUH MODINE SKATE CONCEALED 800 36.2 180 150 SNOW MELT 30 314" FREE (1)1130 120 1 EL446K D1 -03 CW -08 VESTIBULE CEILING HWP-4 B &G 1510 END HEAT 220 940 40 82.0 20 1750 30 6 5 SKATE VARIABLE SPEED DRIVE 800 36.2 5BC SUCTION EXCHANGERS 30 3/4" FREE (1)1130 120 1 BELT D1 -04 CW -08 RENTAL CEILING L-20 AIR BALANCE EL -445K ELEVATOR 4/5 HOTEL 24 4" DISCHARGE 1 1/20 0 N OTES: 5830 SMP -1 B &G 1510 END SNOW 140 926 140 80.3 60 1750 40 6 5 48 36 EF -12 COOK 5G SUCTION MELT 5000 1.6 1828 8614 3 BELT NONE UP HOTEL AIR BALANCE EL -446K ELEVATOR 16 32 A 1 4" 3.24 - BLAST SMP -2 B &G 1510 END SNOW 140 926 140 80.3 &60 1750 40 6 5 A AIR BALANCE EF -13 COOK 5G SUCTION MELT 10 600 0.7 1919 5023 0.5 BELT NONE HORIZONTAL STAIR 5 60 72 4" 15.46 0.18 TOWN L -25 AIR BALANCE EL -445K ELEVATOR 8 VENT 24 52 4" 4.05 SMP-3 B &G 1510 END SNOW 140 577 140 74.0 50 1750 40 6 5 62,600 EF -14 COOK 5G SUCTION MELT 15" 2000 0.25 1106 0.75 BELT MOTORIZED - WITH SA -2 AIR BALANCE EL445K PARKING INTAKE ROOF TOWN 4" 93.1 .08 81,400 L -28 AIR BALANCE EL-446K ICE RINK INTAKE SMP-4 B &G 1510 END SNOW 140 577 140 74.0 50 1750 40 6 5 WITH SA -2 5G SUCTION MELT S932- CWP4 B &G 1510 END CHILLED 60 1385 130 81.6 100 1750 30 8 6 VARIABLE SPEED DRIVE EF -16 COOK 6G SUCTION WATER 16.5" 2400 0.25 853 0.75 BELT MOTORIZED - WITH SA -2 CWP -2 B &G 1510 END CHILLED 60 1385 130 81.6 100 1750 30 8 6 VARIABLE SPEED DRIVE 6G SUCTION WATER CP -I B &G 1510 END CONDENSER 95 2007 75 86.2 50 1750 - 8 6 WITH SA-3 6E SUCTION WATER CP -2 B &G 1510 END CONDENSER 95 2007 75 86.2 50 1750 -- 8 6 EF -18 COOK 6E SUCTION WATER 19.5" 4240 0.25 935 2 BELT MOTORIZED - WITH SA-3 CDR1 LITTLE VCMA -20 CONDENSATE CONDENSATE 120 1 10 - 1/30 -- - -- -- GIANT AREA D S640- CABINET UNIT HEATER SCHEDULE ADDENDUM 14 07.29. DESIG. MFR. MODEL LOW HOT WATER COI DATA MINIMUM MOTOR DATA A 6 0 HZ EWT OF LWT OF EWT LWT GPM PROPYLENE TYPE HP V PH DESIG. MFR./ LOCATION ARRANG. CFM AT SPEED RUNOUT REMARKS 30% MODEL 2 75 8150' MBH OF OF 308 GLYCOL% SIZE � A OF OF °F CUH MODINE STAIR 8 EXPOSED 195 12.2 180 150 1.0 30 3/4" FREE 1/30 120 1 900 BG1 -01 CW 03 15 CEILING 30 -22 14,914 CT -2 MARLEY NC- 8304EL1 1 DISCHARGE 75 900 82 65 CUH MODINE ELEVATOR 1 INVERTED 195 12.2 180 150 1.0 30 314" FREE 1130 120 1 228 AG1 -01 CW 03 VESTIBULE EXPOSED 30 9 115 140 577 40 24 DISCHARGE 1990 AREA C SNOW MELT CUH MODINE STAIR 6 INVERTED 195 12.2 180 150 1.0 30 3/4" FREE 1130 120 1 21.20 CG1 -01 CW 03 HOTEL EXPOSED AT405MHVN 449 134 190 150 1 580 30 DISCHARGE 115 140 926 40 CUH MODINE HOTEL LOBBY INVERTED 790 64.3 180 150 4.0 30 1" FREE (2) 120 1 81 -01 CW 12 VESTIBULE RECESSED EF-4 COOK 445 CPS -A UTILITY SET SE GARAGE 36,000 DISCHARGE 1/20 9436 25 BELT CUH MODINE HOTEL ENTR. INVERTED 270 19.2 180 150 1.0 30 3/4" FREE 1120 120 1 B1 -02 CW 04 VESTIBULE RECESSED L -7 AIR BALANCE LOADING EF -37 60 DISCHARGE 4" 10.14 0.1 7200 CUH MODINE HOTEL ENTR. INVERTED 270 19.2 180 150 1.0 30 3/4" FREE 1120 120 1 BELT B1 -03 CW 04 VESTIBULE RECESSED 72 120 4" 24.58 EXHAUST 17,800 DISCHARGE CUH MODINE REST. ENTR. INVERTED 790 64.3 180 150 4.0 30 1" FREE (2) 120 1 81 -04 CW 12 VESTIBULE RECESSED EF-6 COOK 330 CPSA UTILITY SET KITCHEN EL -445K 16,200 DISCHARGE 1/20 8734 10 BELT CUH MODINE STAIR 9 EXPOSED 195 12.2 180 150 1.0 30 3/4" FREE 1/30 120 1 B1 -05 CW 03 AIR BALANCE CEILING MAU -8 48 36 4" HOTEL 0.1 3200 DISCHARGE CUH MODINE STAIR 7 INVERTED 195 12.2 180 150 1.0 30 3/4" FREE 1/30 120 1 BELT C1 -01 CW 03 VESTIBULE RECESSED ROOF DISH EXHAUST AIR BALANCE EL -445K DISCHARGE 12 12 4" 0.28 0.2 300 WOMENS EF-8 COOK GC -320 CEILING FAN PUBLIC RR - 150 0.3 1500 - 47 W DIRECT CUH MODINE SKATE CONCEALED 800 36.2 180 150 3.0 30 3/4" FREE (1)1/30 120 1 L -13 D1 -01 CW -08 RESTROOM CEILING EF-9 COOK 100C3B CENTRIFUGAL KITCHEN 600 DISCHARGE 1 1120 4937 0.25 BELT MOTORIZED - MENS 0.65 .09 480 ROOF DISH EXHAUST HOOD /DRYER CUH MODINE SKATE CONCEALED 800 36.2 180 150 3.0 30 314" FREE (1)1130 120 1 5000 D1 -02 CW -08 RESTROOM CEILING EF -10 COOK 270 CPSA UTILITY SET KITCHEN 9000 DISCHARGE 1 1/20 7641 5 BELT CUH MODINE SKATE CONCEALED 800 36.2 180 150 3.0 30 314" FREE (1)1130 120 1 EL446K D1 -03 CW -08 VESTIBULE CEILING 24.0 0.13 16,000 I LEASED L -18 DISCHARGE 1 1120 ELEVATOR 16 72 48 CUH MODINE SKATE CONCEALED 800 36.2 180 150 3.0 30 3/4" FREE (1)1130 120 1 BELT D1 -04 CW -08 RENTAL CEILING L-20 AIR BALANCE EL -445K ELEVATOR 4/5 DISH EXHAUST 24 4" DISCHARGE 1 1/20 0 N OTES: 5830 0 M C WATER CHILLER SCHEDULE ADDENDUM 14 07.29. DESIG. MFR. MODEL CAP. TONS CHILLED WATER DATA CONDENSER WATER DATA KW INPUT KW PER TON EWT OF LWT OF GPM PROPYLENE GLYCOL A P FT. W.C. NO. OF PASSES EWT OF LWT OF GPM A P FT. W.C. NO. OF PASSES CH -1 TRANE CVHF 660 57 45 1385 30% 17 2 75 85 1807 19 2 308 0.461 A A � A COOLING TOWER SCHEDULE ADDENDUM 14 07.29. 147 ASI126 HEAT CONDENSER WATER AMBIENT AIR FAN SUMP HEATER 04.11.06 04.14.06 DESIG. MFR. MODEL NO. REMARKS NO. EWT LWT FAN TYPE PROPYLENE A P FT. EWT LWT MIN. PROPYLENE AP FT. MBH CELLS EWT LWT GPM DB WB MOTOR MOTOR KW AMB. GPM GLYCOL % W.C. OF OF °F °F W.C. OF OF HP RPM WATERSIDE OF AT8OMHVIV CT -1 MARLEY NC- 8304EL1 1 85 75 900 82 65 15 1200 30 -22 14,914 CT -2 MARLEY NC- 8304EL1 1 85 75 900 82 65 15 1200 30 -22 EF -2 NOTES: 445 CPS -A UTILITY SET 1. PROVIDE VFD FOR COOLING TOWER FAN. 36,000 HX 2 TOWN S711- PLATE AND FRAME HEAT EXCHANGER SCHEDULE ADDENDUM 14 07.29. 147 ASI126 HEAT WHEEL HOT SIDE COLD SIDE 119 146 OPER. 04.11.06 04.14.06 DESIG. SERVICE MFR. MODEL TRANSFER NO. EWT LWT FAN TYPE PROPYLENE A P FT. EWT LWT APPROX. PROPYLENE AP FT. MBH WEIGHT REMARKS CONTROL REMARKS SF AT S.L. AREA PLATES OF OF GPM GLYCOL % W.C. OF OF GPM GLYCOL % W.C. 0.1 LBS. EF -1 HX -1 WATERSIDE MUELLER AT8OMHVIV 5278 586 A 1 54 45 1385 A I 30 10 A51 42 49 1800 A S' 0 10 6090 14,914 A EXHAUST ECONOMIZER 4" 17.91 0.1 14,000 EF -2 COOK 445 CPS -A UTILITY SET NE GARAGE 36,000 HX 2 TOWN MUELLER AT405MHV 228 69 190 150 360 30 9 115 140 577 40 24 6875 1990 AREA C SNOW MELT L-4 AIR BALANCE EL -445K EF -27 72 60 4" 21.20 0.1 HX-3 HOTEL MUELLER AT405MHVN 449 134 190 150 1 580 30 1 9 115 140 926 40 24 11076 2693 AIR BALANCE Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- MSI.DWG - M002.2 PLOT DATE: 05/25/2006 @ 3: 33pm REV: 05/25/2006 CAD: hdy XREF: tb -a.dwg tb- smoke- defsubl.dwg tb.dwg tb- condo.dwg a x. m fi Arts FAN SCHEDULE ADDENDUM 14 07.29. 147 ASI126 OVERALL WHEEL CFM S.P. 119 146 TIP 04.11.06 04.14.06 149 150 DESIG. MFR. MODEL SERVICE DESIG. MFR. MODEL FAN TYPE SERVICE DIA. AT IN. W.C. APPROX. SPEED MIN, DRIVE DAMPER DISCHARGE CONTROL REMARKS SF AT S.L. 05.26.06 STYLE (INCHES) 8150' AT S.L. RPM (FPM) HP TYPE TYPE ARRANGE. 0.1 14 ,000 EF -1 COOK 445 CPS -A UTILITY SET NW GARAGE 36,000 2.0 810 9436 25 BELT NONE HORIZONTAL L -2 AIR BALANCE EL -445K AHU -1&2 EXHAUST 96 4" 17.91 0.1 14,000 EF -2 COOK 445 CPS -A UTILITY SET NE GARAGE 36,000 2.0 810 9436 25 BELT NONE HORIZONTAL 96 24 4" 33.29 0.1 25,000 EXH AREA C L-4 AIR BALANCE EL -445K EF -27 72 60 4" 21.20 0.1 BOTTOM EF-3 COOK 445 CPSA UTILITY SET SW GARAGE 36,000 2.0 810 9436 25 BELT NONE ANGULAR L -5 AIR BALANCE EL -445K MAU -5 &6 84 96 EXHAUST 28.94 0.1 20,200 UP AREA A EF-4 COOK 445 CPS -A UTILITY SET SE GARAGE 36,000 2.0 810 9436 25 BELT NONE UP BLAST 4" PROVIDE WITH VFD 0.1 11,000 EXHAUST AREA D L -7 AIR BALANCE LOADING EF -37 60 60 4" 10.14 0.1 7200 EF-S COOK 445 CPSA UTILITY SET DOCK 36,000 2.0 810 9436 25 BELT NONE HORIZONTAL EL -445K PROVIDE WITH VFD 72 120 4" 24.58 EXHAUST 17,800 AREA B A I HOTEL AHU-3 & EF-6 COOK 330 CPSA UTILITY SET KITCHEN EL -445K 16,200 2.0 1011 8734 10 BELT NONE UP BLAST AREA B GREASE EXHAUST 6 L -10 AIR BALANCE EL -445K MAU -8 48 36 4" HOTEL 0.1 3200 AREA C EF -7 COOK 100C3B CENTRIFUGAL KITCHEN 600 0.7 1886 4937 0.25 BELT MOTORIZED - ROOF DISH EXHAUST AIR BALANCE EL -445K EXHAUST 12 12 4" 0.28 0.2 300 EF-8 COOK GC -320 CEILING FAN PUBLIC RR - 150 0.3 1500 - 47 W DIRECT BACKDRAFT - L -12 NOT USED HOTEL L -13 AIR BALANCE EL -445K CONDO FCU 24 EF-9 COOK 100C3B CENTRIFUGAL KITCHEN 600 0.7 1886 4937 0.25 BELT MOTORIZED - 1.5 0.65 .09 480 ROOF DISH EXHAUST HOOD /DRYER L -15 AIR BALANCE LEASED CHILLER ROOM 24 96 4" 7.71 0.07 5000 EF -10 COOK 270 CPSA UTILITY SET KITCHEN 9000 1.7 1081 7641 5 BELT NONE UP EL -445K ELEVATOR 4/5 120 48 4" 20.28 GREASE EXHAUST 15,200 L -17 AIR BALANCE EL446K ELEVATOR 13114 BLAST 114 4" 24.0 0.13 16,000 LEASED L -18 AIR BALANCE EL -446K ELEVATOR 16 72 48 4" 12.00 0.13 7,600 EF -11 COOK 80 CPV UTILITY SET KITCHEN 10" 600 0. 1919 5023 0.5 BELT NONE HORIZONTAL L-20 AIR BALANCE EL -445K ELEVATOR 4/5 DISH EXHAUST 24 4" 4.46 - 0 VENT LEASED L -21 AIR BALANCE EL -445K ELEVATOR 13/14 48 36 EF -12 COOK 180 CPSA UTILITY SET KITCHEN 5000 1.6 1828 8614 3 BELT NONE UP GREASE EXHAUST AIR BALANCE EL -446K ELEVATOR 16 32 32 4" 3.24 - BLAST LEASED L23 AIR BALANCE EF -13 COOK 80 CPV UTILITY SET KITCHEN 10 600 0.7 1919 5023 0.5 BELT NONE HORIZONTAL STAIR 5 60 72 4" 15.46 0.18 DISH EXHAUST L -25 AIR BALANCE EL -445K ELEVATOR 8 VENT 24 52 4" 4.05 - - I AREA B L-26 AIR BALANCE EL -446K PARKING 240 84 4" 71.64 .08 62,600 EF -14 COOK 150 ACE -B CENTRIFUGAL TOILET 15" 2000 0.25 1106 0.75 BELT MOTORIZED - WITH SA -2 AIR BALANCE EL445K PARKING INTAKE ROOF EXHAUST 4" 93.1 .08 81,400 L -28 AIR BALANCE EL-446K ICE RINK INTAKE EF -15 COOK 150 ACE-B CENTRIFUGAL AREA B TOILET 15" 1680 i 0.25 976 0.75 BELT MOTORIZED - WITH SA -2 ROOF EXHAUST S932- AREA C EF -16 COOK 165 ACE -B CENTRIFUGAL TOILET 16.5" 2400 0.25 853 0.75 BELT MOTORIZED - WITH SA -2 ROOF EXHAUST AREA C EF -17 COOK 180 CPV UTILITY SET TOILET 18" 4000 0.5 1216 2 BELT MOTORIZED HORIZONTAL WITH SA-3 EXHAUST AREA A EF -18 COOK 195 ACE -B CENTRIFUGAL TOILET 19.5" 4240 0.25 935 2 BELT MOTORIZED - WITH SA-3 ROOF EXHAUST AREA D EF -19 COOK 135 CPV UTILITY SET TOILET 13.5" 1360 0.5 1341 1 BELT MOTORIZED HORIZONTAL WITH SA -1 EXHAUST AREA D EF -20 COOK 180 CPV UTILITY SET TOILET 18" 2080 0.5 877 2 BELT MOTORIZED HORIZONTAL WITH SA-3 EXHAUST AREA D EF -21 COOK 180 CPV UTILITY SET TOILET 18" 4550 0.5 1337 2 BELT MOTORIZED HORIZONTAL WITH SA-3 EXHAUST AREA A EF -22 COOK 135 ACE -B CENTRIFUGAL TOILET 13.5" 1040 0.25 914 0.5 BELT MOTORIZED - WITH SA -1 ROOF EXHAUST AREA D I EF -23 COOK 135 ACE -B CENTRIFUGAL TOILET 13.5" 1460 0.25 1095 0.5 BELT MOTORIZED - WITH SA -1 ROOF EXHAUST AREA A EF -24 COOK 135 CPV UTILITY SET TOILET 13.5" 1760 0.25 1362 0.5 BELT MOTORIZED HORIZONTAL WITH SA -1 EXHAUST AREA B EF -25 COOK 135 ACE-B CENTRIFUGAO TOILET 13.5" 880 0.25 847 0.5 BELT MOTORIZED - WITH SA -1 ROOF I EXHAUST EF -26 COOK 300 CPSA UTILITY SET SPA 30" 12,700 1.0 857 7.5 BELT MOTORIZED HORIZONTAL EXHAUST EF -27 COOK 365 CPV UTILITY SET BALLROOM 36.5" 15,000 1.5 725 7.5 BELT MOTORIZED HORIZONTAL WITH VFD EXHAUST EF -28 COOK 195 ACE -B CENTRIFUGAL CHILLER ROOM 21" 5000 1.0 1159 2 BELT MOTORIZED - ROOF EXHAUST AREA A EF -29 COOK 135 CPV UTILITY SET TOILET 13.5" 1200 0.5 1275 1 BELT MOTORIZED HORIZONTAL WITH SA -1 EXHAUST EF-30 COOK 180 CPV UTILITY SET ICE RINK 18" 3000 0.5 1009 1.5 BELT MOTORIZED HORIZONTAL EXHAUST EF-31 FAN TECH FX 6 IN -LINE DRYER - 197 0.4 2680 84 W BELT NONE - REFER TO PLANS BOOSTER FAN FOR QUANTITY AREA C EF -02 COOK 165 ACE -B CENTRIFUGAL TOILET 16.5" 2240 0.25 950 0.75 BELT MOTORIZED - WITH SA -2 ROOF EXHAUST EF-33 COOK 150 SON-B IN -LINE AREAA 15" 2200 0.4 1429 1 BELT NONE - RETAIL EXHAUST EF -34 COOK GC -144 CEILING TOILET - 80 0.4 934 80 W DIRECT BACKDRAFT REFER TO PLANS FAN EXHAUST FOR QUANTITY AREA D EF-35 COOK 180 CPV UTILITY SET ICE RINK TOILET 18" 3300 0.75 1176 2 BELT MOTORIZED HORIZONTAL WITH SA -1 RETAIL EXHAUST AREA D EF-36 COOK 150 SON-B IN -LINE RETAIL 15" 2710 0.4 1429 1 BELT NONE - EXHAUST EF-37 COOK 245 CPS UTILITY SET AREA A &B GEN EXH 24.5" 7130 2.0 1100 7.5 BELT MOTORIZED HORIZONTAL - EF-38 COOK 70 ACE-B CENTRIFUGAL WATER FEATURE 10" 250 0.5 1806 0.25 BELT MOTORIZED - - ROOF EXHAUST SQUARE EF-39 COOK 70 SQN -B CENTRIFUGAL ZAMBONI 10" 300 0.3 1976 0.33 BELT MOTORIZED SINGLE SIDE IN -LINE EXHAUST COMMERRIAL EF-40 EXHAUSTO BESB -250 BOX DRYER - 1000 1.0 1600 0.5 DIRECT NONE UP 1,2 VENTILATOR EXHAUST NOTES: WITH 2. PRODVIDE ODULATING FAN CONTROL (MODEL ESC 12), LISTED FOR UL 705 SUITABLE FOR VENTING LINT -LADEN AIR FROM DRYERS. LOUVER SCHEDULE ADDENDUM 14 07.29. 147 ASI126 OVERALL DIMENSIORS FREE AIR A P 119 146 ASI093 CCD 025 04.11.06 04.14.06 149 150 DESIG. MFR. MODEL SERVICE 04.17.06 156 158 PR 137 CCD 029 AREA IN W.C. CFM FRAME FINISH REMARKS 05.11.06 177 CCD 033 05.17.06 LENGTH HEIGHT DEPTH SF AT S.L. 05.26.06 STYLE i L -1 AIR BALANCE EL -445K AHU -1&2 60 96 4" 17.91 0.1 14 ,000 AREA C L -2 AIR BALANCE EL -445K AHU -1&2 60 96 4" 17.91 0.1 14,000 AREA C L-3 AIR BALANCE EL -445K MAU-9 96 24 4" 33.29 0.1 25,000 AREA C L-4 AIR BALANCE EL -445K EF -27 72 60 4" 21.20 0.1 15,000 AREA C L -5 AIR BALANCE EL -445K MAU -5 &6 84 96 4" 28.94 0.1 20,200 AREA A L-6 AIR BALANCE EL -445K MAU -7 84 60 4" 14.12 0.1 11,000 AREA D L -7 AIR BALANCE EL -445K EF -37 60 60 4" 10.14 0.1 7200 AREA B L-8 AIR BALANCE EL -445K MAU-3 72 120 4" 24.58 0.1 17,800 AREA B A I AHU-3 & L -9 AIR BALANCE EL -445K MAU -4 96 60 4" 28.71 0.1 21,300 AREA B 6 L -10 AIR BALANCE EL -445K MAU -8 48 36 4" 5.58 0.1 3200 AREA C ZAMBONI L -11 AIR BALANCE EL -445K EXHAUST 12 12 4" 0.28 0.2 300 AREA D L -12 NOT USED L -13 AIR BALANCE EL -445K CONDO FCU 24 12 4" SEE PLANS FOR QUANTITY RUSKIN ELF15J CONDO RANGE 20 12 1.5 0.65 .09 480 SEE PLANS FOR QUANTITY HOOD /DRYER L -15 AIR BALANCE EL -445K CHILLER ROOM 24 96 4" 7.71 0.07 5000 AREA A L -16 AIR BALANCE EL -445K ELEVATOR 4/5 120 48 4" 20.28 0.13 15,200 L -17 AIR BALANCE EL446K ELEVATOR 13114 56 114 4" 24.0 0.13 16,000 L -18 AIR BALANCE EL -446K ELEVATOR 16 72 48 4" 12.00 0.13 7,600 L -19 AIR BALANCE EL -445K STAIR 8 72 84 4" 21.20 0.13 16,500 L-20 AIR BALANCE EL -445K ELEVATOR 4/5 64 24 4" 4.46 - 0 VENT L -21 AIR BALANCE EL -445K ELEVATOR 13/14 48 36 4" 5.58 .. 0 VENT L -22 AIR BALANCE EL -446K ELEVATOR 16 32 32 4" 3.24 - 0 VENT L23 AIR BALANCE EL -445K ELEVATO 84 48 4" 11,000 L -24 AIR BALANCE EL -445K STAIR 5 60 72 4" 15.46 0.18 14,700 L -25 AIR BALANCE EL -445K ELEVATOR 8 VENT 24 52 4" 4.05 - - I L-26 AIR BALANCE EL -446K PARKING 240 84 4" 71.64 .08 62,600 INTAKE A L -27 AIR BALANCE EL445K PARKING INTAKE 264 84 4" 93.1 .08 81,400 L -28 AIR BALANCE EL-446K ICE RINK INTAKE 60 24 4" 4.20 08 3000 1 NOTE: 1. PROVIDE KYNOR FINISH COLOR SELECTION BY ARCHITECT. S932- ; ,_. @ 2003 42140 ARCHITECTURE, INC. OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J ARCHITECTURE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, N W YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO IIN'TERIORDESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 023 ADDENDUM 14 07.29. 147 ASI126 04.10.06 148 PR 124R1 04.11.06 119 146 ASI093 CCD 025 04.11.06 04.14.06 149 150 CCD 026 PR 134 04.14.06 04.17.06 154 PR 136 04.17.06 156 158 PR 137 CCD 029 0424.06 04.26.06 171 CCD 031 05.10.06 173 ASI144 05.11.06 177 CCD 033 05.17.06 183 189 185 CCD 033R1 CCD 41 CCD 40 05.26.06 05.26.06 05.26.06 191 ASI159 05.26.06 i i RD INDEX SHEETS FOR PREVIOUS ISSUE LISTINGS n o PROJECT KEYPLAN FAN COIL UNIT SCHEDUL DESIG. MFR. ! 1 MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM ! TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT LAT MBH GPM WATER © P FT. W.C. °F DB °F WB I °F DB °F WB FCU AG2 -01 TRANE BCHC -18 SNOWMELT MECH RM ( HORIZ 500 - ' 115 HEATING 70 - I .. 60 54 50 2.8 ( INTERNATIONAL MPY -06 COOLING 75 I 60 54 50 I 2.3 112 1 FCU AG2 -02 TRANE BCHC -72 SKI TUNING I HORIZ ( 2000 1 ! 2 1 HEATING 70 - 100 - 3.9 FCU A2-03 ' INTERNATIONAL MPY -06 CONDO i r ( 400 I J HEATING 70 1/20 C LING 75 COOLING 75 60 54 50 9.1 ; FCU AG2 -03 j I TRANE f BCHC -36 j VESTIBULE HORIZ. 1000 i i 50 (2) 1/8 HEATING 70 -- 100 -- CONDO 1 1.9 800 HEATING 40 1/5 LING 80 - 93 - 2.3 OOLING 75 6 54 50 9.1 60 FCU AG2-04 TRANE BCHC WAREHOUSE HORIZ I I 1500 INTERNATIONAL MPY -10 2 HEATING 70 - 100 -- -• 2.9 COOLING 75 60 54 50 I 6.8 FCU A2 -06 FCU AG2 -05 TRANE BCHC I WAREHOUSE HORIZ. 1500 ' 1/20 HEATING TO 75 2 n=ATING 10 - 10 -- 2.9 60 54 50 1.3 COOLING 75 60 54 50 I VERT. 6.8 FCU AG2 -06 TRANE BCHC -36 HOLDING COOLER HORIZ. 1000 ( (2) 118 HEATING { 70 - 100 -- 1.9 54 so 1.3 FCU A2 -08 INTERNATIONAL I MPY -06 CONDO VERT. COOLING 75 60 54 50 112 1 4.5 FCU AG2 -07 TRANE BCHC- OFFICE j HORIZ { 250 I 1/5 HEATING 70 ( - { 100 - I INTERNATIONAL CPY -06 CONDO HORIZ 400 i HEA F ING I I V 1/20 F COO LING 75 -- j 112 LIN 75 60 54 50 i 9.1 FCU BG2 -01 TRANE BCHC ELECTRICAL HORIZ. 2000 , 1 1.3 2 HEATING I 70 - 100 -- 800 3.9 HEATING 40 1/5 LIN -- 93 - 2.3 COOLING 75 60 1 54 50 9.1 FCU BG2 -02 j TRANE I BCHC -18 SKI CLUB { I HORIZ 500 CONDO VERT. 115 mr -A1ING ' 7u - lUU - - 1 1 1 60 CO 75 60 54 so i 2.3 MPY -10 FCU BG2 -03 TRANS BCHC -18 ! STAIR VESTIBULE ± HORIZ. 500 -- 93 115 - QLLN - 0 HEATING 70 - 100 -- 1 60 54 1 50 2 1 8 FCU A2 -13 COOLING 75 60 54 so ; 2.3 HEATING 70 1120 CO OLING 7 FCU BG2-04 TRANS BCHC- OFFICE HORIZ. 250 1/5 HEATING ' 70 - 100 -- 1.3 FCU 132 -01 INTERNATIONAL MPY -06 HOTEL VERT, 400 COOLING 75 60 54 50 1 FCU DG2 -01 TRANE BCHC- OFFICE HORIZ. 250 60 1/5 HEATING 70 - 100 - INTERNATIONAL MPY -06 HOTEL VERT, 400 ' 1/20 HEATING 70 75 -- 112 1 - COOLING 7 5 60 54 50 FCU AG1 -01 TRANE BCHC -72 LOCKERS HORIZ. 2000 I C��I Q2_n3 2 HEATING 70 - 100 ' - 3.9 COOLING ' 75 6Q 64 50 50 9.1 2.8 FCU AG1 -02 TRANE BCHC -36 HOUSEKEEPING HORIZ 1000 800 (2) 118 HEATING 70 -- 100 -- 1.9 I 60 54 50 COO LING 75 60 54 50 MPY -06 4.5 VERT. FCU AG1 -03 TRANE BCHC -36 PUMP ROOM HORIZ 1000 -- (2) 118 HEATING 70 - 100 - 1.9 1 60 1 54 50 1 1.3 FCU 132 -06 INTERNATIONAL MPY -06 COOLING 7 400 1/20 HEATING 70 COO LING 75 4.5 112 FCU er_1 ne TRANE BCHC -36 a [III nllurr MANAGER Uf%017 lnnn I ! oI 1tR � HEATING 1 70 - 100 - 1.9 FCU 132 -07 INTERNATIONAL I HOTEL I 400 ! 1/20 HEATING 70 COO LING 75 COOLING 75 60 54 50 4.5 FCU AG1 -05 TRANE BCHC -36 LOCKERS HORIZ 1000 54 1 50 (2) 1/8 HEATING 70 - 100 - HOTEL 1.9 400 HEATING 70 1/20 COOLING 75 -- 112 1 - 1 COOLING 75 60 54 50 4.5 60 FCU AG1-06 TRANE BCHC STORAGE HORIZ 1500 INTERNATIONAL MPY -06 2 HEATING 70 - 100 - -- 2.9 1 ' *54 COOLING 1 76 1 60 ' 54 1 50 1 1 6.6 FCU 132 -10 FCU AG1 -07 TRANS BCHC MIENS / WOMENS HORIZ 1500 HEATING 70 1/20 COO LING 75 2 HEATING 70 1 -- 100 - 2.9 60 64 so 1.3 COO LING f 75 60 54 50 VERT. 6.8 FCU AG1 -08 TRANE BCHC STORAGE HORIZ 1500 1 2 _CQO HEATING 70 - 100 - 2.9 54 50 1.3 FCU 132 -12 INTERNATIONAL MPY -10 CONDO VERT. COO LING 75 60 54 50 93 6.8 FCU AG1-09 FCU AG1 -10 TRANE _� TRANE BCHC BCHC- STORAGE CHILDRENS PROGRAM HORIZ HORIZ 1500 1500 2 2 HEATING 1 70 - 100 - 2.9 INTERNATIONAL , MPY -10 CONDO VERT. 800 1/5 HEATING 40 C -- 93 COOLING HEATING 1 75 1 70 60 - 54 100 50 6.8 2.9 FCU C1 -07 TRANE BCHC -72 RETAIL HORIZ, 2000 2.8 COOLIN 75 70 -- 100 - 6.8 3.9 FCU AG1 -11 TRANE BCHC- CHILDRENS PROGRAM HORIZ 1500 1 2 HEATING 70 - 100 - 50 2.9 9.1 50 FCU Dl -01 TRANE BCHC -36 RETAIL HORIZ 1000 HOTEL VERT. QLIN 75 70 -- 100 - 6.8 1.9 FCU AG1 -12 TRANE BCHC -72 ELECTRICAL HORIZ. 2000 2 HEATING 70 - 100 - 3.9 4.5 MPY -06 FCU D1 -02 TRANE BCHC -36 1 RETAIL HORIZ 1000 •- 112 COOLING 75 60 54 50 - 9.1 _ FCU AG1 -13 TRANE BCHC -72 _ STORAGE HORIZ 2000 1.3 2 HEATING 70 - 100 54 50 3.9 4.5 _ FCU D1 -03 TRANS BCHC -72 ! RETAIL HORIZ 2000 LIN 75 70 -- 100 - 9.1 3.9 FCU AG1 -14 TRANE BCHC -36 STORAGE HORIZ 1000 1 VERT. (2) 118 HEATING TO 1/20 HEATING TO 7 100 -- - 1.9 9 1 FCU D1 -04 TRANE BCHC-181 RETAIL HORIZ ! COO LING 7 70 -- 100 - 4.5 MPY -06 FCU AG1 -15 TRANS BCHC -36 TELECOM i HORIZ 1000 -- 112 (2) 1/8 HEATING 70 - 100 -- -50 1.9 2.3 _ FCU D1 -05 TRANE BCHC -72 RETAIL HORIZ. 2000 I COOLING 75 60 54 50 4.5 3.9 FCU BG1 -01 TRANE BCHC -36 CORRIDOR HORIZ 1000 (2) 118 HEATING 70 - 100 - 50 1.9 9.1 1.3 FCU D1 -06 TRANE BCHC -36 RETAIL HORIZ. 1000 I 400 COOLING 75 60 54 so 4.5 1.9 FCU BG1-02 TRANS BCHC -18 CORRIDOR HORIZ 500 1 60 7/5 HEATING 70 75 100 64 0 1 FCU DI -07 TRANE BCHC -72 RETAIL HORIZ 2000 - ( 2 (� 75 70 -- 100 ! - 2.3 3.9 FCU BG1-03 TRANE BCHC -18 MANAGER HORIZ 500 FCU C2 -09 1/5 HEATING 70 - 100 - 1 9.1 112 FCU D1 -08 TRANE BCHC -72 RETAIL HORIZ - 2000 54 50 COO LING 75 60 54 50 - 2.3 3.9 FCU BG1.04 TRANE BCHC -36 RECEPTION HORIZ. 1000 - (2) 1/8 HEATING 70 - 100 54 50 9.1 60 FCU D1 -09 TRANE BCHC -72 RETAIL HORIZ 2000 INTERNATIONAL MPY -10 COOLING 75 60 54 so - 4.5 3.9 FCU BG1 -05 TRANE BCHC- CONFERENCE HORIZ 250 1/5 HEATING 70 - 100 - 60 2.8 9.1 FCU C2 -12 FCU D1 -10 TRANE BCHC -36 RETAIL HORIZ. 1000 1 HEATING 40 1/5 COO LING CO LING 75 60 54 50 - 1.9 FCU BG1-06 TRANE BCHC -36 OFFICE HORIZ 1000 (2) 1/8 HEATING 70 - 100 54 50 1.9 4.5 FCU D1 -11 TRANE BCHC -36 RETAIL HORIZ 1000 1 DOLING 75 60 54 50 4.5 1.9 FCU BG1 -07 TRANE BCHC -36 OFFICE HORIZ 1000 INTERNATIONAL BCHC -36 (2) 118 HEA TING 7 - 100 - { 50 1.9 4.5 I { COOLING 75 60 54 50 4.5 4.5 FCU C2 -151 FCU BG1 -08 TRANE BCHC -36 OFFICE HORIZ. 1000 HEATILIN NG 70 (2) 1/8 COO LING 75 (2) 1/8 HEATING 70 100 _ _ 1.9 NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR4C(Nbff CFM /COIL CAPACITIES BASED ON (MEDIUM) SPEED OPERATION. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. S. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 40 % PROPYLENE GLYCOL. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. S830 -11(1 ST) Go 54 4.5 COO LING 75 60 64 50 HORIZ 4.5 FCU BG1-09 TRANE BCHC -36 I OFFICE I HORIZ 1000 1.9 (2) 118 HEATING 70 - 100 - 1.9 54 50 1 4.5 FCU C2 -17 { INTERNATIONAL BCHC -36 RETAIL HORIZ L-I RG 75 0 HEATING 70 (2) 118 COOLING 7 -- 100 4.5 FCU BG1 -10 TRANE BCHC I OFFICE HORIZ 600 1/5 HEATING 70 - 100 - FCU C2 -18 FCU D2 -01 1 BCHC -36 MPY -06 COOLING 75 60 54 50 -- 100 FCU EG1 -11 TRANE BCHC- TELECOM HORIZ 250 1/5 HEATING 70 - 100 - 4.5 1 60 54 50 COO LING 75 60 64 so MPY-06 CONDO__ VERT. FCU BG1 -12 TRANE BCHC- TELECOM HORIZ 250 - 1/5 HEATING 70 - 100 - ! � FCU D2 -03 ! INTERNATIONAL I CONDO 7 800 I so � 40 1/5 COOLING 80 -- 83 FCU CG1 -01 FCU CG1 -02 TRANE TRANE BCHC -18 BCHC -72 STORAGE PUMP ROOM HORIZ HORIZ 500 2000 1 1/5 2 HEATING 0 - 100 1 - 1 _ INTERNATIONAL CPY -06 CONDO HORIZ. 400 1120 HEATING 70 COOLING 75 COOLING HEATING 75 70 60 54 100 50 2.3 3.9 i : f : _ 60 54 50 �QQL I. NG ; 75 _ FCU D2.05 INTERNATIONAL f MPY -10 ( 9.1 VERT. j FCU CG1 -03 TRANE BCHC -18 TELECOM HORIZ. 500 - 115 HEATING 70 - 100 - { 1 60 54 50 2.8 FCU 132 -06 INTERNATIONAL MPY -10 I COOLING 7 800 ! HEATING 40 I 115 COO LING 80 2.3 93 FCU D01 -01 TRANE BCHC- ICE RINK REF. ROOM HORIZ 1500 2 HEATING 70 - 100 - 2.9 M _ INTERNATIONAL CPY -10 CONDO HORIZ. 800 1 I _ HEATING ! 40 1/5 C LIN 80 COOLING 75 60 54 50 6.8 FCU DG1 -02 TRANE BCHC- I ICE RINK REF. ROOM 1 HORIZ 1500 54 50 2 HEATING TO - 100 BCHC -72 _ 2.9 r2OOOT HEATING . 70 2 1 _ COOLING 75 -- 100 - 3.9 COOLING 75 60 54 so ! 6.8 60 FCU DG1 -03 TRANE BCHC- 1 I OFFICE HORIZ 250 TRANE BCHC -72 115 HEATING 70 -- 100 - -- 100 ! _ 3.9 _i T 54 SO 9.1 FCU D2 -101 TRANE I BCHC -72 � HORIZ, ( 2000 1 ; 2 HEATING 70 COO LING 75 - - 100 ! - 3.9 00 54 so 9.1 FCU D2 -11 TRANE BCHC -72 RETAIL HORIZ 2000 NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COJUSNiT CFWCOIL CAPACITIES BASED ON (MEDIUM) SPEED OPERATION. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 5. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 40 PROPYLENE GLYCOL. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. $830- 11(G2 &G1) FA N COIL UNIT SCHEDULE DESIG. ' MFR. { MODEL E SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL AT 8150' ESP I RPM {MOTOR! HP E SERVICE EAT LAT MBH GPM WATER 1 A P FT. I W.G. OF DB ' OF WB j OF I DB OF WB FCU Al -01I TRANE BCHC -36 ( RETAIL HORIZ. 1000 - (2) 1/8 HEATING 70 - 100 - 60 54 50 2.8 ( INTERNATIONAL MPY -06 COOLING 75 60 54 50 HEATING 70 ! 1120 COOLING 75 4.5 112 FCU Al -021 TRANE BCHC -72 RETAIL HORIZ. 2000 ! 2 HEATING 70 -- 100 - 3.9 FCU A2-03 ' INTERNATIONAL MPY -06 CONDO VERT. r ( 400 I J HEATING 70 1/20 C LING 75 COOLING 75 60 54 50 9.1 FCU Al -03 TRANS BCHC -72 RETAIL HORIZ. 2000 i 50 I 2 HEATING TO -- 100 -- CONDO 3.9 800 HEATING 40 1/5 LING 80 - 93 - 2.3 LIN 75 60 54 50 9.1 60 FCU Al -04 TRANS BCHC -72 RETAIL HORIZ. 2000 INTERNATIONAL MPY -10 2 HEATING 70 - { 100 -- -• 3.9 COO LING 75 60 54 50 1 9.1 FCU A2 -06 FCU Al -05 TRANE ! BCHC -72 l RETAIL HORIZ I 2000 ' 1/20 HEATING TO 75 2 HEAT iNG 70 -- i 00 - 3.9 60 54 50 1.3 COOLING 75 60 54 1 50 I VERT. 9.1 FCU Al -06 TRANE BCHC -72 RETAIL HORIZ 2000 ( 2 HEATING 70 -- 100 1 - 3.9 54 so 1.3 FCU A2 -08 INTERNATIONAL I MPY -06 CONDO VERT. C OOLING - 75 6 0 HEATING 70 1120 COOLING 75 50 112 9.1 FCU Al -07' TRANE BCHC -72 RETAIL HORIZ. 2000 i 2 HEATING 70 -- 100 - 3.9 INTERNATIONAL CPY -06 CONDO HORIZ 400 i HEA F ING I I V 1/20 F COO LING 75 -- j 112 COO LING 75 1 54 50 i 9.1 FCU Al -08 TRANE BCHC -36 RETAIL HORIZ. 1000 1.3 (2) 118 HEATING 70 . 60 -- 100 - 800 1.9 HEATING 40 1/5 LIN -- 93 - 2.3 I COOLING 75 60 54 50 4.5 FCU Al -09 I TRANE ( BCHC -36 RETAIL HORIZ. 1000 CONDO VERT. (2) 118 HEAiIi�NG ' 7u -- ivu - - i.y 1 1 60 COO LING 75 60 54 so i 4.5 MPY -10 FCU Al -101 TRANE BCHC -36 RETAIL HORIZ. 1000 -- 93 (2) 1/8 HEATING { 70 •- 100 60 54 1 50 2 1 8 FCU A2 -13 COO LINQ _ 75 60 54 i so ; 4.5 HEATING 70 1120 CO OLING 7 FCU B1 -01 TRANE BCHC -90 HOTEL LOBBY HORIZ. 3000 HEATING TO - 100 - 1.3 FCU 132 -01 INTERNATIONAL MPY -06 HOTEL VERT, 400 COOLING 75 60 54 50 1 FCU B1 -02 TRANE BCHC -90 HOTEL LOBBY HORIZ. 3000 60 54 HEATING 70 1.3 FCU B2 -02 INTERNATIONAL MPY -06 HOTEL VERT, 400 ' 1/20 HEATING 70 75 -- 112 1 - COOLING 7 FCU B1 -03 TRANE I BCHC -90 RESTAURANT HORIZ. 3000 C��I Q2_n3 1►JTEDA�ATt�W - Q • L HEATING 70 •- 100 - HEATING 115 COOLING 80 7 5 6Q 54 50 50 2.8 FCU B1 -04 TRANE BCHC -90 RESTAURANT HORIZ 3000 800 HEATING 70 -- 100 - 60 54 50 COO LING 75 60 54 1 50 MPY -06 HOTEL VERT. FCU B1 -05 TRANE BCHC -90 ! BAR HORIZ. 3000 -- 1 HEATING TO -- 100 1 - 1 60 1 54 50 1 1.3 FCU 132 -06 INTERNATIONAL MPY -06 COOLING T 400 1/20 HEATING 70 COO LING 75 -- 112 CCU C111 TRANE I QGHP-36 I f%IMIGE .0 { lnnn f HEATING 70 -- 100 -- 1.9 FCU 132 -07 INTERNATIONAL MPY -06 HOTEL VERT. 400 1/20 HEATING 70 COO LING 75 COOLING " 75 60 54 50 4.5 FCU C1 -02 TRANE BCHC -36 LOCKERS HORIZ. 1000 54 1 50 (2) 1/8 HEATING 70 -- 100 - HOTEL 1.9 400 HEATING 70 1/20 COOLING 75 -- 112 1 - 1 COOLING 75 60 54 50 4.5 60 FCU C1 -03 TRANE BCHC -36 LOBBY HORIZ 1000 INTERNATIONAL MPY -06 (2) 1/8 HEATING 70 -- 100 - -- 1.8 1 *54 COOLING 1 75 1 60 1 54 ' 60 1 1 4.5 FCU 132 -10 FCU C1 -04 TRANE BCHC -36 STAIR HORIZ. 1000 HEATING 70 1/20 COO LING 75 (2) 1/8 HEATING 70 1 -- 100 - 1.9 60 64 so 1.3 COO LING 75 80 54 50 VERT. 4.5 FCU C1 -05 TRANE BCHC -36 RETAIL HORIZ 1000 1 (2) 1/8 HEATING 70 -- 100 - 1.9 54 50 1.3 FCU 132 -12 INTERNATIONAL MPY -10 CONDO VERT. COOL ING 75 60 54 50 93 4.5 FCU Cl -06 TRANE BCHC -18 RETAIL HORIZ 500 1/5 HEATING 70 -- 100 - 1 INTERNATIONAL , MPY -10 CONDO VERT. 800 1/5 HEATING 40 C -- 93 COOLING 75 60 54 50 2.3 FCU C1 -07 TRANE BCHC -72 RETAIL HORIZ, 2000 2.8 2 HEATING 70 -- 100 - 400 3.9 HEATING 70 1/20 CO 75 •- 112 -- 1 LING 75 60 54 50 60 9.1 50 FCU Dl -01 TRANE BCHC -36 RETAIL HORIZ 1000 HOTEL VERT. (2) 1/8 HEATING 70 -- 100 - - 1.9 1 1 60 COO LING 75 60 1.3 FCU C2 -02 4.5 MPY -06 FCU D1 -02 TRANE BCHC -36 1 RETAIL HORIZ 1000 •- 112 I (2) 1/8 HEATING 70 -- 100 - 1.9 60 54 so 1.3 FCU C2 -03 COOLING 75 60 54 50 4.5 . 75 1/20 HEATING 70 COO LING 75 FCU D1 -03 TRANS BCHC -72 ! RETAIL HORIZ 2000 2 HEATING 70 -- 100 - 54 3.9 1.3 FCU C2 -04 INTERNATIONAL MPY -06 HOTEL VERT. ! 400 COO LING 1/20 HEATING TO 7 - r 112 - 9 1 FCU D1 -04 TRANE BCHC-181 RETAIL HORIZ 500 1/5 _ TING 70 -- 100 - INTERNATIONAL MPY -06 HOTEL VERT. 400 ! -- 112 - COOLING 7 -50 2.3 _ FCU D1 -05 TRANE BCHC -72 RETAIL HORIZ. 2000 I 2 HEATING 70 VERT. 400 3.9 -- 112 - 1 COOLING 75 60 54 1 50 50 9.1 1.3 FCU D1 -06 TRANE BCHC -36 RETAIL HORIZ. 1000 I 400 (2) 118 HEATING 70 -- 100 1 1.9 60 54 50 COOLIN 75 60 64 0 MPY -06 4.5 VERT. FCU DI -07 TRANE BCHC -72 RETAIL HORIZ 2000 - ( 2 (� HEATING 1 70 -- 100 ! - 3.9 60 54 50 1.3 FCU C2 -09 INTERNATIONAL MPY -06 COOLING VERT. 60 54 HEATING 1 TO 1/20 1 LM 75 9.1 112 FCU D1 -08 TRANE BCHC -72 RETAIL HORIZ - 2000 54 50 2 HEATING 70 - - 100 - CONDO 3.9 800 j ( j HEATING 40 1/5 COOLING 80 •- 93 - 2.3 QQLIN 75 60 54 50 9.1 60 FCU D1 -09 TRANE BCHC -72 RETAIL HORIZ 2000 INTERNATIONAL MPY -10 2 HEATING 70 -- 100 - •• 3.9 - 2.3 COOLING 75 60 2.8 9.1 FCU C2 -12 FCU D1 -10 TRANE BCHC -36 RETAIL HORIZ. 1000 1 HEATING 40 1/5 COO LING (2) 1/8 HEATING TO -- 100 - 1.9 2.8 COOL ING 75 60 54 50 VERT. 4.5 FCU D1 -11 TRANE BCHC -36 RETAIL HORIZ 1000 1 (2) 1/8 HEATING 70 -- 100 1.9 54 50 1.3 FCU C2 -14 INTERNATIONAL BCHC -36 RETAIL HORIZ. COOLING 75 60 54 50 100 4.5 I 4.5 FCU C2 -151 INTERNATIONAL BCHC -36 RETAIL HORIZ. 1000 HEATILIN NG 70 (2) 1/8 COO LING 75 -- 100 1.9 _ _ NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR4C(Nbff CFM /COIL CAPACITIES BASED ON (MEDIUM) SPEED OPERATION. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. S. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 40 % PROPYLENE GLYCOL. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. S830 -11(1 ST) FAN COIL UNIT SCHEDULE DEIGG. j MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM AT 8150'1 ESP RPM MOTOR EAT HP SERVICE OF ° F DB WB LAT MBH I GPM WATER I G P F T T. I W.C. °F DB °F WB FCU A2 -01 INTERNATIONAL CPY -10 CONDO HORIZ. 800 HEATING 40 115 COOLING 80 - 93 - 60 54 50 2.8 FCU A2 -02 INTERNATIONAL MPY -06 I CONDO VERT. 400 HEATING 70 ! 1120 COOLING 75 -- 112 - 1 60 54 50 1.3 FCU A2-03 ' INTERNATIONAL MPY -06 CONDO VERT. r ( 400 I J HEATING 70 1/20 C LING 75 -- 112 - 1 60 54 50 1.3 FCU A2 -04 INTERNATIONAL MPY -10 I CONDO ( VERT. 800 HEATING 40 1/5 LING 80 - 93 - 2.3 60 54 1 1 2.8 FCU A2 -05 INTERNATIONAL MPY -10 CONDO VERT. 1 800 I HEA T iNG 1 40 I 115 I I COOLING I 80 -• 93 60 54 50 2.8 FCU A2 -06 INTERNATIONAL MPY -06 CONDO VERT. 400 ( ' 1/20 HEATING TO 75 -- 112 - 1 60 54 50 1.3 FCU A2-07 I +' MPY -06 ' CONDO I VERT. 400 _QQQ HEATING 70 1120 COOLING 75 -- ( 112 - 1 1 6Q 54 so 1.3 FCU A2 -08 INTERNATIONAL I MPY -06 CONDO VERT. 400 HEATING 70 1120 COOLING 75 -- 112 - 1 I 60 54 50 1.3 FCU A2 -09 INTERNATIONAL CPY -06 CONDO HORIZ 400 i HEA F ING I I V 1/20 F COO LING 75 -- j 112 1 60 I 1.3 FCU A2 -10 INTERNATIONAL MPY -10 CONDO VERT. 800 j HEATING 40 1/5 LIN -- 93 - 2.3 2.8 FCU A2 -11 INTERNATIONAL MPY -06 CONDO VERT. 400 " j i HEATING 70 1/20 COOLING 75 -- 112 - 1 1 60 54 50 1.3 FCU A2 -12 INTERNATIONAL MPY -10 CONDO VERT. 800 HEATING 40 115 COOLIN 80 -- 93 - 2.3 60 54 1 50 2 1 8 FCU A2 -13 INTERNATIONAL MPY -06 CONDO VERT. 400 ; HEATING 70 1120 CO OLING 7 •- 112 - 1.3 FCU 132 -01 INTERNATIONAL MPY -06 HOTEL VERT, 400 HEATING 1 70 1/20 - COO LING 75 -- 112 - 1 60 54 50 1.3 FCU B2 -02 INTERNATIONAL MPY -06 HOTEL VERT, 400 ' 1/20 HEATING 70 75 -- 112 1 - 1 60 54 50 1.3 C��I Q2_n3 1►JTEDA�ATt�W - Q • L MCV__tA G�.I:D.�. V I AnA � HEATING 115 COOLING 80 60 54 50 2.8 FCU 132 -04 INTERNATIONAL MPY -10 CONDO VERT. 800 HEATING 40 1/5 CO OLING 80 - 93 60 54 50 2.8 FCU 62 -05 INTERNATIONAL MPY -06 HOTEL VERT. 400 1/20 HEATING TO COOLING 1 75 -- 112 -- 1 1 60 1 54 50 1 1.3 FCU 132 -06 INTERNATIONAL MPY -06 CONDO VERT. 400 1/20 HEATING 70 COO LING 75 -- 112 - 1 60 54 50 1.3 FCU 132 -07 INTERNATIONAL MPY -06 HOTEL VERT. 400 1/20 HEATING 70 COO LING 75 -- 112 1 60 54 1 50 1.3 FCU B2 -08 INTERNATIONAL MPY -06 HOTEL VERT. 400 HEATING 70 1/20 COOLING 75 -- 112 1 - 1 60 1.3 FCU 82 -09 INTERNATIONAL MPY -06 HOTEL VERT. 400 1/20 HEATING 70 LIN 75 -- 1 *54 1.3 FCU 132 -10 INTERNATIONAL MPY -06 HOTEL VERT. 400 HEATING 70 1/20 COO LING 75 -- 1 60 64 so 1.3 FCU 82 -11 INTERNATIONAL MPY -06 CONDO VERT. 400 1/20 HEATING TO COOLING 75 -- 112 - 1 60 54 50 1.3 FCU 132 -12 INTERNATIONAL MPY -10 CONDO VERT. 800 HEATING 1 40 1/5 QLIN - 93 - 2.3 2.8 FCU 62 -13 INTERNATIONAL , MPY -10 CONDO VERT. 800 1/5 HEATING 40 C -- 93 - 2.3 so 2.8 FCU 82 -14 INTERNATIONAL MPY -06 CONDO VERT. 400 HEATING 70 1/20 CO 75 •- 112 -- 1 60 54 50 1.3 FCU C2 -01 INTERNATIONAL MPY -06 HOTEL VERT. 400 HEATING 70 1/20 75 -- 112 - 1 1 60 1.3 FCU C2 -02 INTERNATIONAL MPY -06 HOTEL VERT. 400 HEATING 70 1/20 COOLING •- 112 - 1 60 54 so 1.3 FCU C2 -03 INTERNATIONAL i MPY -06 HOTEL VERT. 400 . 75 1/20 HEATING 70 COO LING 75 -- 1 112 -- I 1 60 54 50 1.3 FCU C2 -04 INTERNATIONAL MPY -06 HOTEL VERT. ! 400 1/20 HEATING TO 7 - r 112 - 1 1.3 FCU C2 -05 INTERNATIONAL MPY -06 HOTEL VERT. 400 HEATING 70 1120 COOLING 75 -- 112 - 1 60 54 50 1.3 FCU C2 -06 INTERNATIONAL MPY -06 CONDO VERT. 400 HEATING TO 1/20 COOLING 75 -- 112 - 1 60 54 50 1.3 FCU C2.071 INTERNATIONAL MPY -06 CONDO VERT. 400 1/20 HE ATING 70 COOLING 75 -- 112 - 1 60 54 50 1.3 FCU C2 -08 INTERNATIONAL MPY -06 CONDO VERT. 40 f HEATING 70 1120 COOLING 75 •- 112 - 1 60 54 50 1.3 FCU C2 -09 INTERNATIONAL MPY -06 CONDO VERT. ( 400 1 HEATING 1 TO 1/20 1 LM 75 -- 112 - 1 60 54 50 1.3 FCU C2 -10 INTERNATIONAL MPY -10 CONDO VERT. 800 j ( j HEATING 40 1/5 COOLING 80 •- 93 - 2.3 60 54 _ 50 2.8 FCU C2 -11 INTERNATIONAL MPY -10 CONDO VERT. 800 HEATING 40 1/5 COO LING •• 93 - 2.3 2.8 FCU C2 -12 INTERNATIONAL MPY -10 CONDO VERT. 800 I HEATING 40 1/5 COO LING -- 83 - 2.3 2.8 FCU C2 -13! INTERNATIONAL MPY -06 CONDO VERT. 400 HEATING 70 1/20 DOLING 75 1 •- 112 -- 1 1 6C 54 50 1.3 FCU C2 -14 INTERNATIONAL BCHC -36 RETAIL HORIZ. 1000 HEATING 70 (2) 118 75 -- ( 100 4.5 FCU C2 -151 INTERNATIONAL BCHC -36 RETAIL HORIZ. 1000 HEATILIN NG 70 (2) 1/8 COO LING 75 -- 100 1.9 _ _ Go 54 4.5 FCU C2 -16 INTERNATIONAL BCHC -36 RETAIL HORIZ 1000 } (2) 118 HEATING TO DOLING 75 -- 100 - 1.9 60 54 50 1 4.5 FCU C2 -17 { INTERNATIONAL BCHC -36 RETAIL HORIZ 1000 HEATING 70 (2) 118 COOLING 7 -- 100 - 1.9 4.5 FCU C2 -18 FCU D2 -01 INTERNATIONAL INTERNATIONAL BCHC -36 MPY -06 RETAIL I CONDO HORIZ VERT. 1000 400 HEATING 70 (2) 118 - COOLING 75 HEATING 70 1/20 COO LING - 75 -- 100 1.9 .. 54 1 112 .. 4.5 1 60 54 50 1.3 FCU D2 -02 INTERNATIONAL MPY-06 CONDO__ VERT. 400 f HEATING 70 1/20 4- � HEATING -- _ 112 - 1 � FCU D2 -03 ! INTERNATIONAL I MPY -10 1 CONDO VERT. 1 800 I � 40 1/5 COOLING 80 -- 83 1 2.3 { _ 60 54 50 2.8 FCU D2 -04 I INTERNATIONAL CPY -06 CONDO HORIZ. 400 1120 HEATING 70 COOLING 75 - 112 - 1 i : f : _ 60 54 50 1.3 FCU D2.05 INTERNATIONAL f MPY -10 ( CONDO VERT. j 800 1 HEATING 40 1/5 COOLING 80 -- 83 - 2.3 60 54 50 2.8 FCU 132 -06 INTERNATIONAL MPY -10 I CONDO VERT. 800 ! HEATING 40 I 115 COO LING 80 -- 93 - 2.3 60 1 54 50 2.8 FCU D2 -07 INTERNATIONAL CPY -10 CONDO HORIZ. 800 1 I _ HEATING ! 40 1/5 C LIN 80 -- 93 I - 2.3 ��- 60 C 54 50 2.8 FCU D2 -081 TRANE BCHC -72 RETAIL HORIZ r2OOOT HEATING . 70 2 1 _ COOLING 75 -- 100 - 3.9 ! 60 54 _ 50 9.1 FCU D2 -08 TRANE BCHC -72 RETAIL HORIZ. 2000 HEATING TO 2 COO LING 75 -- 100 - 3.9 54 SO 9.1 FCU D2 -101 TRANE I BCHC -72 RETAIL HORIZ, ( 2000 ; 2 HEATING 70 COO LING 75 - - 100 ! - 3.9 00 54 so 9.1 FCU D2 -11 TRANE BCHC -72 RETAIL HORIZ 2000 HEATING 1 70 2 COOLING 1 75 -- 100 - 3.9 60 54 50 1 9.1 FCU D2 -12 TRANE BCHC -72 RETAIL HORIZ 2000 1 HEATING 1 70 2 _ 75 - 100 - 3.9 54 50 9.1 FCU D2 -13 TRANE BCHC -72 RETAIL HORIZ. 2000 ---COO HEATING 70 2 75 -- 100 - 3.9 so 9.1 __CQO LING ; NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR4CMIL%r CFM /COIL CAPACITIES BASED ON (MEDIUM) SPEED OPERATION. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. S. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 40 % PROPYLENE GLYCOL. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. S830- 11(2ND) n 203 42140 ARCHITECTURE, IN4L ov' G`LAS YojF�``o , 3496 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART 1 HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIVBID 02.15.05 N PROJECT KEYPLAN MECHANICAL SCHEDULES Cator, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- MSI.DWG _ M002.3 PLOT DATE: 02/10/2005 @ 9:49om REV: 02/10/2005 CAD: lisal XREF: tb.dwg (( If () 1 II _L T1v'v .✓•K_P FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT LAT MBH GPM WATER A P FT. W.C. OF DB I O I WB O DB OF WB FCU A3-01 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 CONDO 1/20 HEATI G 70 . - 1 - 13.4 -- 1.7 1 1 13.4 1 1.7 01-17-06 085 PR 067BC 02-13-06 111 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-02 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 - 112 13.4 1 1.7 NOWDUCTED 1 COOLNG 75 60 54 50 7.0 1.3 1.4 FCU A3-03 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1.7 1 1 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 I 115 HEATING 40 - 93 - 33.9 2.3 11.7 1COOLING 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A3-05 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 11.7 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A3-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 .. 112 _. 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-07 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - 112 .. 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-08 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 1 -- 112 - 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-09 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 -- 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A3-10 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-11 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 . HEATING ..... 70 112 - 13.4 1 1.7 NOWDUCTED 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3-12 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 -- 33.9 2.3 11.7 P 1 LING 60 54 50 17.2 2.8 10.1 FCU A3-13 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU A3-14 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 I 1/20 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A3 -15 INTERNATIONAL CPY-08 CONDO CORRIDOR HORIZ. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.9 10.1 FCU A3-16 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 H RATRZ 70 - -- 93 - 33.9 _T5_ 1 1.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 133-01 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 -- 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU 133-02 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 - 112 - 13.4 1 1.7 NOWDUCTED 1 1 CO LING 75 1 60 54 50 7.0 1.3 1.4 FCU 133-03 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 -- 33.9 2.3 11.7 NOWDUCTED COOLING so 6 54 so 17.2 2.8 10.1 FCU B3-04 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1._3 1.4 FCU 133-05 INTERNATIONAL MPY-04 CONDO VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED _T_ COOLING, 75 60 54 so 7.0 1.3 1.4 FCU B3-06 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATI 70 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 so 7.0 1.3 1.4 FCU B3-07 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 1-15AIT 70 - 11 2 13.4 i - 1.7 NOWDUCTED COOLING ONLY - COOLING 75 60 54 so 7.0 1.3 1.4 FCU B3-08 INTERNATIONAL MPY-04 HOTEL VERT. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU B3-09 INTERNATIONAL MPY-04 HOTEL VERT. 400 0.27 1/20 HEATING 70 .. 112 1 -- 13.4 1 1.7 - COOLING 75 60 54 so 7.0 3 1.4 FCU B3-10 INTERNATIONAL MPY-04 HOTEL VERT. 400 0.27 1/20 HEATING 70 - 112 - 13.4 1 1.7 1 COOLING 75 60 54.. §Q 7.0 3 1.4 FCU 133-11 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 ._&Q 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 so 7.0 1.3 1.4 FCU 133-12 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU B3-13 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 - 33.9 2.3 11.7 NOWDUCTED 1 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 133-14 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 INOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU B345 NOT USED MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 1 1 COOLING 75 60 54 so 7.0 1.3 1.4 FCU B3-16 NOT USED MPY-08 CONDO VERT. $00 0.27 115 HEATING 40 93 -- 33.9 2.3 11.7 1 COOLING 80 60 54 so 17.2 2.8 10.1 FCU B3-17 NOT USED MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 .. 112 -- 13.4 1 1.7 21 . 1 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU B3-18 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 NOWDUCTED COOLING 80 60 54 50 17.2 1 2.8 10.1 FCU B3-19 TRANE BCHC-54 CONDO CORRIDOR HORIZ. 1500 0.27 1045 3/4 HEATING 70 - 90 _fO _0 --- 34.8 2.4 0.1 NOWDUCTED 1 COOLING COOLING 75 60 54 50 24.0 4•3 1.2 FCU C3-01 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 HEATING 1/20 HEATING 70 -- 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 HEATING 1/20 HEATING 70 .. -- Tf2 - " ­­'.. - 13.4 1 1.7 1 80 COOLING 75 00 54 so 7.0 1.3 1.4 FCU C3-03 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 HEATING 1/20 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED 1 COOLING 75 COOLING 75 60 54 50 7._0 2.8 1.4 FCU C3-04 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 HEATING 115 HEATING 40 93 2.3 33.9 2.3 11.7 NOWDUCTED COOLING 80 COOLING 80 §Q 4 so 17.2 2.8 10.1 FCU C3-05 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 HEATING 1/20 HEATING 70 93 2.3 1 13.4 1 1.7 NOWDUCTED 60 64 50 17.2 2.8 10.1 FCU CS-17 NOT USED COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-06 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED FCU C5-18 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-07 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 80 60 54 so 17.2 2.8 10.1 FCU C5-19 INTERNATIONAL r Z5 60 54 50 7.0 1.3 1.4 FCU C3-08 INTERNATIONAL MPY-04 HOTEL VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 80 60 54 50 17.2 2.8 10.1 FCU D5-01 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU C3-09 INTERNATIONAL MPY-08 HOTEL VERT. $00 0.27 1/5 HEATING 46 -- 93 33.9 2.3 11.7 75 60 54 so 7.0 1 1.4 FCU D5 -02 INTERNATIONAL COOLING 80 0 9A 50 17.2 2.8 10.1 FCU C3-10 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1 1.7 NON-DUCTED 60 54 so 7.0 1.3 1.4 FCU D5-03 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU C3-11 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING- 70 - 112 -- 13.4 1 1.7 NON-DUCTED 60 54 50 17.2 2.8 10.1 FCU D5-04 INTERNATIONAL COOLING 75 60 54 60 7.0 1.3 1.4 FCU C3-12 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 .. 112 - 13.4 1 1.7 NOWDUCTED 60 54 50 17.2 2.8 10.1 FCU DS-05 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-13 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 �4 1 2 13.4 1 1.7 NOWDUCTED 60 54 50 7.0 1.3 1.4 FCU D5-06 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-14 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 - 112 - 13.4 1 1.7 NOWDUCTED 60 54 so 17.2 2.8 10.1 FCU D5-07 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-15 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 NOWDUCTED 1/20 HEATING 70 112 1 13.4 1 1.7 NOWDUCTED 60 54 50 7.0 1.3 1.4 FCU D5-08 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-16 INTERNATIONAL MPY-04 HOTEL VERT. 400 0.27 1120 HEATING- 70 112 -- 13.4 1 1.7 NOWDUCTED 60 54 50 17.2 2.8 10.1 FCU D5-09 INTERNATIONAL COOUNa.-..-- 75 60 54 50 7.0 1.3 1.4 FCU C3-17 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 NOWDUCTED 1120 HEATING 70 -- 112 13.4 1 1.7 NOWDUCTED 60 54 50 7.0 1.3 1.4 FCU D540 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU C3-18 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 NOWDUCTED 1/5 HEATING 40 93 33.9 2.3 11.7 75 60 54 50 7.0 1.3 1.4 FCU D541 1 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU C3.19 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 11.7 NOWDUCTED 60 54 50 17.2 2.8 10.1 FCU D5-12 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU C3-20 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 1 60 54 50 7.0 1 1.4 FCU DS-13 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU C3-21 TRANE BCHC-90 HOTEL LOBBY HORIZ. 2500 0.6 1100 11/2 HEATING 70 - 00 56.6 4 0.1 75 60 54 50 7.0 1.3 1.4 FCU DS-14 INTERNATIONAL COOLING 75 60 54 so 40.3 7.3 2.1 FCU C3-22 INTERNATIONAL CPY-08 CONDO CORRIDOR HORIZ. $00 0.27 1/5 HEATING 40 -- 93 -- 33.9 2.3 11.7 75 60 54 so 7.0 1 1.4 FCU DS-15 1 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D3-01 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 112 -- 13.4 - 1 - 1.7 NOWDUCTED 60 54 50 17.2 - 2.8 10.1 FCU D546 INTERNATIONAL COOLING 75 60 54 50 7.0 - 17 - 1.4 FCU D3-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - .......... 1 2 ;� _f3_ _4 2.3 1.7 75 60 54 50 7.0 1.3 1.4 FCU D5.17 COOLING COOLING 75 60 54 50 7.0 1,3 1.4 FCU D3-03 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 1/20 HEATING 70 112 112 13.4 1 13.4 1 1.7 75 60 54 50 7.0 1.3 1.4 FC D5-18 COOLING COOLING 75 60 54 50 7.0 1.3 1.4 FCU 133-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1120 I 115 HEATING 40 112 93 13.4 33.9 2.3 11.7 - ;z^ - 60 54 so 7.0 1.3 1.4 1 ri 7- if � COOLING $o 60 54 50 17.2 2.8 10.1 FCU 133-05 INTERNATIONAL I MPY-08 LOCK OFF I VERT. 800 0 AEW AMON 1/5 HEATING 40 93 - 33.9 2.3 11.7 NOWDUCTED NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. OCT 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. Kffwpmw� 4. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30 % PROPYLENE GLYCOL. S830-11(5TH) a COOLING 80 60 54 50 17.2 2.8 10.1 FCU D3-06 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 112 .. 13.4 1 1.7 NOWDUCTED COOLINrg 75 60 54 50 7.0 1.3 1.4 FCU D3-07 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1120 HEATING 70 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 so 7.0 1.3 1.4 FCU D3-08 INTERNATIONAL MPY-04 HOTEL VERT. 400 0 1/20 HEATING 70 .. 1 12 - 13.4 1 1.7 NOWDUCTED COOLING 5 60 54 50 7.0 1.3 1.4 FCU D3-09 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 7 60 54 50 7.0 1.3 1.4 FCU D340 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 77 AO -- 112 13.4 1 1.7 NOWDUCTED COOLING 1 75 60 54 50 7.0 1.3 1.4 FCU D341 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 6J 54 50 7.0 1.3 1.4 FCU D3-12 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 so 17.2 2.8 10.1 FCU D3-13 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D3-14 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 1 41 FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL ESP RPM MOTOR HP SERVICE mr EAT LAT MBH GPM WATER A P - FT. OF 7r, O An O S4 OF Nn FCU D3-15 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 CONDO 1120 HEATING 70 . - 112 - 13.4 1 1.7 1 1 13.4 1 1.7 01-17-06 085 PR 067BC 02-13-06 111 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D3-16 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 1 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D3-17 INTERNATIONAL MPY-04 CONDO 1 CORRIDOFO& VERT. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1.7 1 1 1 I COOLING 75 60 1 54 1 50 7.0 13 1.4 FCU D3-18 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 I 115 1 HEAT 40 - 93 -- 33.9 2.3 11.7 1COOLING 1 COOLING 80 60 54 1 50 1 17. -2.8 1 10.1 NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. A 4. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30% PROPYLENE GLYCOL. A FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT LAT MBH GPM WATER A P FT. W.C. OF DB OF WB OF DB OF WB FCU A4-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 f CONDO 1120 HEATING 70 AST 058 112 HEATING 13.4 1 1.7 1 1 13.4 1 1.7 01-17-06 085 PR 067BC 02-13-06 111 COOLING 75 60 1 54 so 7.0 1.3 1.4 FCU A4-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A4-03 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 - 93 33.9 2.3 11.7 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A4-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 -- 33.9 2.3 11.7 1COOLING 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A4-05 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 - 93 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A4-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 -- 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A4-07 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 its HEATING 40 - 93 .. 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A4-08 INTERNATIONAL CPY-04 CONDO HORIZ, 400 0.27 1/20 HEATING 70 1 -- 112 - 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A4-09 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 - 33.9 2.3 11.7 ICOOLING 80 60 1 54 50 17.2 2.8 10.1 FCU A4-10 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU A4-11 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 - 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A4-12 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 1 93 -- 33.9 2.3 1 11.7 P 1 'ng- CjNeN-0__ FCU A4-13 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU A4-14 INTERNATIONAL CPY-08 CONDO CORRIDOR HORIZ. 800 0.27 I 115 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A44 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 134-01 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 - 112 13.4 1 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU 134-02 NOT USED MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU 134-03 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 - 112 - 13.4 1 1.7 NOWDUCTED 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU 134-04 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU 134-05 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 1 60 54 50 17.2 2.8 10.1 FCU B4-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED _T_ COOLING 75 60 54 50 7.0 1.3 1 1.4 FCU B4-07 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU 134-08 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 11.7 - COOLING 80 60 54 50 17.2 2.8 1 10.1 FCU B4-09 INTERNATIONAL CPY-08 CONDO CORRIDOR HORIZ. $00 0.27 115 HEATING 40 - 93 33.9 2.3 1 11.7 COOLING 80 60 54 so 17.2 2.8 10.1 FCU 134-10 NOT USED MPY-04 CONDO VERT. 400 0.27 1/2 HEATING 70 .. 112 1 -- 13.4 1 1.7 - COOLING 75 60 54 so 7.0 1.3 1.4 FCU C4-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU C4-02 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1.7 NON-DUCTED COOLING 75 60 54 50 1 7.0 1.3 1.4 FCU C4-03 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 g2.3 1.4 FCU C4-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 1 11.7 NOWDUCTED 1 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C4-05 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 13.4 1 1.7 INOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU C4-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 1 1 COOLING 75 60 54 so 7.0 1.3 1.4 FCU C4-07 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 115 HEATING 40 93 -- 33.9 2.3 11.7 1 COOLING 80 60 54 so 17.2 2.8 10.1 FCU C4-08 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 .. 112 -- 13.4 1 1.7 21 . 1 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C4-09 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 so 7.0 1.3 1 1.4 FCU C4-10 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 I HEATING 70 112 13.4 1 1.7 NOWDUCTED 1 COOLING COOLING 75 60 54 50 7.0 1.3 1.4 FCU C441 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 HEATING 1/20 HEATING 70 -- 112 - 13.4 1 1.7 NOWDUCTED COOLING 75 COOLING 76 60 54 so 7.0 1.3 1.4 FCU C4-12 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 HEATING 1/20 HEATING 70 - 112 - 13.4 1 1.7 80 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C4-13 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 HEATING 1/5 HEATING 40 93 1 33.9 2.3 11.7 1 COOLING 75 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 0444 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 HEATING 1/20 HEATING 70 112 2.3 13.4 1 1.7 NOWDUCTED COOLING 80 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C4-15 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 HEATING 1/5 HEATING 40 93 2.3 1 33.9 2.3 11.7 80 60 64 50 17.2 2.8 10.1 FCU CS-17 NOT USED COOLING 80 60 54 50 17.2 2.8 10.1 FCU C4-16 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 FCU C5-18 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU C4-17 NOT USED 93 33.9 2.3 11.7 1 COOLING 80 60 54 so 17.2 2.8 10.1 FCU C5-19 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 115 HEATING FCU C4-18 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 1/5 HEATING 40 93 - 33.9 2.3 11.7 80 60 54 50 17.2 2.8 10.1 FCU D5-01 INTERNATIONAL COOLING 80 60 54 so 17.2 2.8 10.1 FCU C4-19 INTERNATIONAL CPY-08 CONDO CORRIDOR HORIZ. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 75 60 54 so 7.0 1.3 1.4 FCU D5 -02 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 75 60 54 so 7.0 1.3 1.4 FCU D5-03 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU D4-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 - 112 - 13.4 1 1.7 80 60 54 50 17.2 2.8 10.1 FCU D5-04 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU D4-03 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 .. 93 .• 33.9 2.3 11.7 80 60 54 50 17.2 2.8 10.1 FCU DS-05 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 75 60 54 50 7.0 1.3 1.4 FCU D5-06 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-05 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 - 112 - 13.4 1 1.7 A) 60 54 so 17.2 2.8 10.1 FCU D5-07 INTERNATIONAL COOLING 75 60 1 54 50 7.0 1.3 1.4 FCU D4-06 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 NOWDUCTED 115 HEATING 40 93 1 33.9 2.3 11.7 441. 60 54 50 7.0 1.3 1.4 FCU D5-08 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-07 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 -- 13.4 1 1.7 NOWDUCTED 60 54 50 17.2 2.8 10.1 FCU D5-09 INTERNATIONAL COOLING, 75 60 54 50 7.0 1.3 1.4 FCU D4-08 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 NOWDUCTED 1/5 HEATING 40 -- 93 33.9 2.3 11.7 75 60 54 50 7.0 1.3 1.4 FCU D540 INTERNATIONAL COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-09 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 NOWDUCTED 1/20 HEATING 70 112 13.4 1 1.7 75 60 54 50 7.0 1.3 1.4 FCU D541 1 INTERNATIONAL COOLING 75 60 54 50 7.0 1.3 1.4 FCU D4-10 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED 60 54 50 17.2 2.8 10.1 FCU D5-12 INTERNATIONAL COOLING 75 60 1 54 50 7.0 1.3 1.4 FCU D4-11 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 z HEATING 40 93 33.9 2.3 11.7 1 60 54 50 7.0 1 1.4 FCU DS-13 INTERNATIONAL OLING5 80 60 54 50 17.2 2.8 10.1 FCU D4-12 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 HEATING 70 -- 112 13.4 1 1.7 75 60 54 50 7.0 1.3 1.4 FCU DS-14 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU D4-13 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 H E AT ING 70 112 -- 13.4 1 1.7 75 60 54 so 7.0 1 1.4 FCU DS-15 1 INTERNATIONAL C OOLING OOLING 75 60 54 50 7.0 1.3 1.4 FCU D4-14 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 80 60 54 50 17.2 - 2.8 10.1 FCU D546 INTERNATIONAL COOLING 75 60 54 so 7.0 1.3 1.4 FCU D4-15 1 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 1 HEATING 40 - 93 33.9 2.3 11.7 75 60 54 50 7.0 1.3 1.4 FCU D5.17 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D4-16 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1.7 1120 HEATING 70 -- 112 -- 13.4 1 1 1.7 COOLING 1 75 60 54 50 7.0 1.3 1.4 FC D5-18 COOLING 75 60 1 54 50 7.0 1.3 1.4 FCU D447 INTERNATIONAL MPY-04 CONDO nrinnanrin VERT. 400 0.27 i I 1120 I HEATING 70 112 - 13.4 1 1.7 COOLING - ;z^ - 60 54 so 7.0 1.3 1.4 1 ri 7- if � . A A A I 4x i i pg) A 4k 4�k A A, A 0 Cator, Ruma & Assoc. FILENAME: P: \PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P-MS1.DWG - M002.4 PLOT DATE: 03/03/2006 0 9: 24om REV. 03/03/2006 CAD: mmg XRER tb-o.dwg tb-smoke-defsubl.dwg tb.dwg tb-condo.dwg ♦ ki A FAN COIL UNIT SCHEDULE DESIG. MFR. DESIG. MFR. MODEL SERVICE eeiimpeii ARRANG. FAN DATA CFM TOTAL AT 8150' COIL DATA RPM REMARKS CFM TOTAL ESP RPM MOTOR HP SERVICE eeef:!Nrz EAT LAT MBH 7.9 GPM q.3 WATER A P FT. --4-+- O :F6 OF 69 OF 54- OF so FCU D4-18 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 AST 058 1120 HEATING 70 11 112 - 13.4 1 1.7 01-17-06 085 PR 067BC 02-13-06 111 COOLING 75 60 54 I COOLING 75 1 60 54 1 50 7.0 1 1.3 1 1.4 NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. A 4. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30% PROPYLENE GLYCOL. 400 S830-11(4TH) FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT LAT MBH GPM WATER A P FT. W.C. OF DB OF - WB OF DB OF WB FCU A5-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 045 1/20 HEATING 70 AST 058 112 - 13.4 1 1.7 ASI 070 01-03-06 078 PR 052 01-17-06 085 PR 067BC 02-13-06 111 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A5-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 1 112 13.4 1 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A5-03 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU AS-04 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 1/5 HEATING 40 - 93 -- 33.9 2.3 11.7 1COOLING 1 1 80 60 54 50 17.2 2.8 10.1 FCU A5-05 INTERNATIONAL MPY-08 CONDO VERT. 800 1 0.27 115 HEATING 40 - 93 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A5-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 1 7.0 1.3 1.4 FCU A5-07 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU AS-08 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 1 -- 112 - 13.4 1 1 1.7 COOLING 75 60 54 1 50 7.0 1.3 1.4 FCU A5-09 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 - 1 33.9 2.3 11.7 COOLING 80 60 54 so 17.2 2.8 10.1 FCU A5.10 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 - 13.4 1 1 1.7 NOWDUCTED COOLING 75 60 54 so 7.0 1.3 1.4 FCU A5-11 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 1 HEATING 70 112 1 -- 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A5-12 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 115 HEATING 40 93 -- 33.9 2.3 11.7 'ng- CjNeN-0__ FCU A5-13 INTERNATIONAL MPY-04 CONDO 1 VERT. T. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 75 60 54 50 7.0 1.3 ;11.4 Xq FCU A6-14 INTERNATIONAL MPY-08 CONDO LOFT VERT. 800 0.27 1/5 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A5-15 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 115 HEATING 40 93 33.9 1 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 135-01 INTERNATIONAL CPY-04 CONDO HORIZ. 400 I 0.27 1/20 HEATING 70 - 112 13.4 1 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU B5-02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 - 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU B5-03 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 1/5 HEATING 1 40 - 93 N54 33.9 1 2.3 11.7 C O OLING 80 60 50 17.2 2.8 10.1 FCU B5-04 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU BS-05 NOT USED I FCU B5-06 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 13.4 1 1.7 NOWDUCTED _T_ COOLING 1 5 60 54 50 7.0 1.3 1.4 FCU B5-07 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 - 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU 135-08 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 Its HEATING 40 .. 93 33.9 2.3 11.7 - COALING 80 60 54 so 17.2 2.8 10.1 FCU B5 -09 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 11.7 COOLING 80 60 64 50 17.2 2.8 10.1 FCU C5-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/2 HEATING 70 .. 112 1 -- 13.4 1 1.7 - COOLING 75 60 54 so 7.0 1.3 1.4 FCU C64112 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 64 50 7.0 1.3 1.4 FCU C5-03 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 .. 1 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C5-04 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C5-05 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 I 1/20 I HEATING 1 70 112 13.4 1 1.7 NOWDUCTED 1 1 1 COOLING 1 75 60 54 50 7.0 1.3 1.4 FCU C5-06 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C5-07 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 1 HEATING 40 93 33.9 2.3 11.7 1 80 60 54 50 17.2 2.8 10.1 FCU C5-08 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 -- 13.4 1 1.7 COOLING 75 60 54 50 7.0 1 1.3 1.4 FCU C5-09 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1 HEATING 70 112 13.4 1 1.7 NON-DUCTED ,4 . COOLING 75 60 64 so 7.0 1.3 1.4 FCU CS-10 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C5-11 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 64 50 7.0 - 1 - .3 FCU C5-12 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 HEATING 70 112 13.4 1 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C5 -13 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 Its HEATING 40 93 - 33.9 2.3 11.7 - COOLING 80 60 54 50 17.2 2.8 10.1 FCU C5-14 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1120 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU C5.15 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 its HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C5-16 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 1 11.7 COOLING 80 60 64 50 17.2 2.8 10.1 FCU CS-17 NOT USED FCU C5-18 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 1 COOLING 80 60 54 so 17.2 2.8 10.1 FCU C5-19 INTERNATIONAL CPY-08 CONDO HORIZ. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D5-01 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 1 112 - 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU D5 -02 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU D5-03 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 1 -- 93 - 33.9 2.3 11. COOLING 80 60 54 50 17.2 2.8 10.1 FCU D5-04 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU DS-05 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D5-06 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 so 17.2 2.8 10.1 FCU D5-07 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 1 -- 13.4 1 1 1.7 NOWDUCTED 1 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D5-08 INTERNATIONAL MPY-08 CONDO VERT. $00 0.27 115 1 ICOOLING HEATING 40 93 33.9 2.3 11.7 80 60 54 50 17.2 2.8 10.1 FCU D5-09 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 HEATING 70 - 1 112 13.4 1 1.7 NOWDUCTED 1 1 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D540 INTERNATIONAL MPY-04 LOCK OFF VERT. 400 0 1/20 I HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU D541 1 INTERNATIONAL MPY-08 CONDO VERT. 800 1 0.27 115 HEATING 40 93 - 33.9 2.3 11.7 1 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D5-12 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU DS-13 INTERNATIONAL CPY-04 CONDO HORIZ. 400 0.27 1120 HEATING 70 112 - 13.4 1 1.7 1 0_LING 1 75 60 54 50 7.0 1.3 1.4 FCU DS-14 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 MATING 70 112 13.4 1 1.7 COOLING 75 60 54 so 7.0 1.3 1.4 FCU DS-15 1 INTERNATIONAL MPY-08 CONDO VERT. 800 0.27 - 115 HEATING 40 .. 93 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 - 2.8 10.1 FCU D546 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D5.17 INTERNATIONAL MPY-04 CONDO VERT. 1 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 1 75 60 54 50 7.0 1.3 1.4 FC D5-18 INTERNATIONAL MPY-04 I CONDO CORRIDOR VERT. 400 - 0.27 HEATING 1 70 112 .. 13.4 1 1.7 - COOLING 75 60 54 so 7.0 1.3 1.4 1 1 AEW AMON ne NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. OCT 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. Kffwpmw� 4. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30 % PROPYLENE GLYCOL. S830-11(5TH) a 1�§C L S L Es OWNER/DEVELOPER IL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD I p 'A Itj *AKH Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HARTIHOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEV ELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION BATE 002 003 004 DD FROG 1 DD FROG 2 PRICING PING 04,12.04 05.21.04 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT/BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD FROG. 2 05,27.05 017 CD FROG. 2R 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDENDUM 14 07,29.05 045 ASI 057 12-15-05 058 AST 058 12-13-05 059 ASI 062 12-19-05 068 ASI 070 01-03-06 078 PR 052 01-17-06 085 PR 067BC 02-13-06 111 PR 094BC 03-01-06 PROJ= N PROJECT KMIAN Elm 11111110901211=114 FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA _. COIL DATA REMARKS CFM TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT LAT MBH GPM WATER d P FT. W.C. OF DB °F WS °F DS °F WB FCU A6 -01 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 317 1/5 HEATING 40 - 93 ET -2 33.9 2.3 11.7 - HEATING WATER 12 3500 ET-3 BELL AND GOSSETT B -1000 264 COOLING 80 60 54 54 17.2 2.8 10.1 FCU A6 -02 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 ET-5 1/20 HEATING 70 112 SNOWMELT 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU A6 -03 INTERNATIONAL CPY -04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 -- 13.4 1 1.7 COOLING 1 75 60 54 50 7.0 1.3 1.4 FCU A6-04 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 1 COOLING 80 60 54 50 17.2 2.8 10.1 FCU A6 -05 INTERNATIONAL CPY -04 CONDO HORIZ. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1 1.4 FCU A6 -06 INTERNATIONAL CPY -08 CONDO CORRIDOR HORIZ. 800 0.27 0.27 1/5 HEATING 40 70 93 112 1 33.9 2.3 11.7 COOLING 80 60 54 50 1 17.2 2.8 10.1 FCU 86 -01 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 0.27 1/20 HEATING 70 -- 112 93 1 13.4 1 1.7 COOLING 1 75 60 54 50 7.0 1.3 1.4 FCU 86 -02 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 0.27 1/5 HEATING 1 40 70 93 112 33.9 2.3 11.7 COOLING 1 80 60 54 50 17.2 2.8 10.1 FCU 86 -03 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 0.27 1/5 HEATING 40 70 93 112 33.9 2.3 11.7 COOLING 80 1 60 54 50 17.2 2.8 10.1 FCU B6 -04 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 0.27 1120 HEATING 70 -- 112 -- 13.4 1 1.7 COOLING 75 60 1 54 50 7.0 1.3 1.4 FCU B6 -05 NOT USED INTERNATIONAL CPY -06 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 1 COOLING 75 60 I 54 50 1.3 FCU 86 -06 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 0.27 1120 HEATING 70 40 112 - 13.4 1 1.7 COOLING 75 60 1 54 50 7.0 1.3 1 1,4 FCU 86 -07 INTERNATIONAL CPY -04 CONDO HORIZ. 400 0.27 0.27 1120 HEATING 70 -- 112 93 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU 136 -08 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 0.27 1/5 HEATING 40 40 93 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU 86 -09 INTERNATIONAL CPY -08 CONDO CORRIDOR HORIZ. 800 0.27 0.27 1/5 HEATING 40 70 93 112 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -01 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 0.27 1120 HEATING 70 40 112 93 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C6 -02 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU C6 -03 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6-04 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13A 1 1.7 NOWDUCTED COOLING 75 60 64 50 7.0 1.3 1.4 FCU C6 -05 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -06 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 1 13.4 1 1.7 NON - DUCTED 1 COOLING 75 60 54 50 1 7.0 113 1.4 FCU C6 -07 INTERNATIONAL MPY -08 CONDO VERT., 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -08 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C6 -09 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1120 HEATING 70 1 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 1 7.0 1.3 1.4 FCU C6 -10 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU G6.11 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 115 HEATING 40 1 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -12 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 1 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU C6 -13 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -14 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 •- 93 -- 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -15 INTERNATIONAL CPY -08 CONDO HORIZ. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU C6 -16 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1 1.3 1.4 FCU C647 INTERNATIONAL CPY -08 CONDO CORRIDOR HORIZ. 800 0.27 115 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6 -01 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D6 -02 INTERNATIONAL CPY -04 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 1 75 60 1 54 50 7.0 1.3 1.4 FCU D6 -03 INTERNATIONAL MPY -08' CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6-04 INTERNATIONAL MPY-04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D6 -05 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 -• 13.4 2.3 11.7 , & PR C COOLING 80 60 54 50 7.0 2.8 10.1 FCU D6 -06 INTERNATIONAL MPY -08 LOCK OFF VERT. 800 0 1/5 HEATING 40 93 33.9 2.3 1 11.7 NOWDUCTED COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6 -07 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 60 17.2 2.8 10.1 FCU D6 -08 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 1 7.0 1.3 1.4 FCU D6 -09 NOT USED FCU D6 -10 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1/20 HEATING 70 112 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7,0 1.3 1.4 FCU D6 -11 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6 -12 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6 -13 INTERNATIONAL MPY -04 LOCK OFF VERT. 400 0 1/20 HEATING 70 -• 112 -- 13.4 1 1.7 NOWDUCTED COOLING 75 60 54 50 7.0 1.3 1.4 FCU D6 -14 INTERNATIONAL MPY -04 CONDO VERT. 400 0.27 1120 HEATING 70 112 13.4 1 1.7 COOLING 75 60 54 50 7.0 1.3 1.4 FCU D6.15 INTERNATIONAL MPY -08 CONDO VERT. 800 0.27 1/5 HEATING 40 - 93 33.9 2.3 11.7 COOLING 80 60 54 50 17.2 2.8 10.1 FCU D6 -16 INTERNATIONAL MPY -04 CONDO CORRIDOR VERT. I 400 I 0.27 1/20 HEATING 70 112 13.4 1 1.7 COOLING 1 75 60 54 1 50 7.0 1.3 1.4 I NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. 4. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30 % PROPYLENE GLYCOL. 5830 11(6TH) A P R55R 1 A PR, 5550 C 11 01 A I 0 1 01 11 FAN COIL UNIT SCHEDULE DESIG. MFR. MODEL SERVICE ARRANG. FAN DATA COIL DATA REMARKS CFM TOTAL AT 8150' ESP RPM MOTOR HP SERVICE EAT EAT MBH GPM WATER d P FT. W.C. °F DB °F WB °F DB °F WB FCU C7 -01 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 317 1/20 HEATING 70 3500 112 ET -2 BELL AND GOSSETT 1 317 - HEATING WATER 12 3500 ET-3 BELL AND GOSSETT B -1000 264 COOLING 75 60 54 50 ET-4 1.3 04 -19 -06 FCU C7 -02 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 ET-5 1120 HEATING 1 70 112 SNOWMELT 1 COOLING 75 60 54 50 1.3 FCU C7 -03 INTERNATIONAL MPY40 CONDO VERT. 800 0.27 115 HEATING 40 93 2.3 COOLING 1 80 1 60 54 50 2.8 FCU C7-04 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 1120 HEATING 70 112 1 COOLING 75 60 54 50 1.3 FCU C7 -05 NOT USED HEATING COOLING FCU C7 -06 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 1/20 HEATING 70 112 1 COOLING 75 60 54 50 1.3 FCU C7 -07 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 115 HEATING 40 93 2.3 COOLING 80 60 54 50 2.8 FCU C7 -08 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 1/20 HEATING 70 112 1 COOLING 75 60 54 50 1.3 FCU C7 -09 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 1120 HEATING 70 112 1 COOLING 75 60 54 50 1.3 FCU C7 -10 INTERNATIONAL MPY -06 CONDO VERT. 400 0.27 1/20 HEATING 70 -- 112 -- 1 COOLING 75 60 54 50 1.3 FCU 137 -01 INTERNATIONAL CPY -06 CONDO HORIZ. 400 0.27 1/20 HEATING 70 112 1 COOLING 75 60 I 54 50 1.3 FCU 137 -02 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 1/5 HEATING 40 93 2.3 COOLING 1 50 2.8 FCU D7 -03 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 115 HEATING 40 93 2.3 COOLING 80 60 54 50 2.8 FCU D7 -04 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 115 HEATING 40 93 2.3 COOLING 80 60 54 50 2.8 FCU D7 -05 INTERNATIONAL CPY -06 CONDO HORIZ 400 0.27 1/20 HEATING 70 112 1 COOLING 75 60 54 50 1.3 FCU D7 -06 INTERNATIONAL MPY -10 CONDO VERT. 800 0.27 115 HEATING 40 93 2.3 COOLING 80 60 54 50 2.8 NOTES: 1. EXTERNAL STATIC PRESSURE DOES NOT INCLUDE UNIT CASING, FILTERS OR COILS. 2. HEATING COIL CAPACITY BASED ON 180 °F EWT, AND 30 °F DELTA T. 3. CHILLED WATER COOLING COIL CAPACITY BASED ON 45 °F EWT, AND 12 °F DELTA T. 5. HEATING AND COOLING COILS SELECTIONS BASED ON A SOLUTION OF 30 % PROPYLENE GLYCOL. 5830- 11(7TH) FINTUBE E5 A F%^DIATION SCHEDULE BTUH/ GPM/ ELEMENT ENCLOSURE DESIG. MFR. MODEL NO. LF LF PIPE SIZE FIN SIZE FINS/ HEIGHT DEPTH REMARKS ROWS ELEMENT ELEMENT MATERIAL MATERIAL FT IN. IN. FTR -1 VULCAN DURAVANE 1 800 0.1 1.114" COPPER .02" ALUM 48 10 6 PEDESTAL NO � ,1. HEATING WATER 30 GLYCOL SOLUTION. HVAC EXPANSION TANK SCHEDULE DEF. SUB. 04.05.06 CAPACIT PRE- CHARGE OPER. ACCEPT. TANK DESIGNATION MANUFACTURER MODEL SERVICE PRESSURE WEIGHT REMARKS VOL. VOL. PSIG LBS ET -1 BELL AND GOSSETT B -1200 317 - HEATING WATER 12 3500 ET -2 BELL AND GOSSETT B -1200 317 - HEATING WATER 12 3500 ET-3 BELL AND GOSSETT B -1000 264 PR 055BC CHILLED WATER 12 3000 03 -08 -06 ET-4 BELL AND 04 -19 -06 TOWN SNOWMELT 12 GOSSETT RESORT 12 ET-5 BELL AND GOSSETT SNOWMELT 5120-1 ROOF HOOD SCHEDULE HOOD DESIG. MFR. MODEL SYSTEM SERVICE THROAT DAMPER FREE AREA REMARKS LOCATION DIM, SF RH -1 GREENHECK FABRA HOOD ROOF ELEVATOR 8 18x24 GRAVITY 3 A RH -2 GREENHECK FABRA HOOD ROOF ELEVATOR 10 18x24 GRAVITY 3 5932-4 Cotor, Ruma & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- MS1.DWG - M002.5 PLOT DATE: 04/28/2006 @ 11: 33am REV: 04/28/2006 CAD: hdy XREF: tb -a.dwg tb- smoke- defsubl.dwg tb.dwg tb- condo.dwg MIN W. FAI 01 Aku SMOKE CONTROL GENERAL NOTES: SMOKE CONTROL SYSTEM RESPONSE TIME SHALL BE SUCH THAT FULL OPERATIONAL MODE BE ACHIEVED BEFORE THE CONDITIONS IN THE SPACE EXCEED THE DESIGN SMOKE CONDITION AS REQUIRED BY IBC 909.17. ALL DEVICES, EQUIPMENT, COMPONENTS AND SEQUENCES SHALL BE INDIVIDUALLY TESTED TO DETERMINE THEIR FUNCTION, SEQUENCE AND APPLICABLE CAPACITY PER IBC 909.18. A COMPLETE REPORT OF TESTING SHALL BE PREPARED BY THE DESIGNATED SPECIAL INSPECTOR OR AGENCY. THE RESPONSIBLE DESIGNER SHALL REVIEW SUCH REPORT AND PROVIDE HIS SIGNATURE, SEAL AND DATE 0 N THE REPORT. A COPY OF THE FINAL REPORT SHALL BE FILED WITH HE BUILDING OFFICIAL AND AN IDENTICAL COPY MAINTAINED IN AN APPROVED LOCATION AT THE BUILDING. IBC 909.18.8.3. PPRA L IN 2 @ 2003 42140 ARCHITECTURE, INC. I OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OR RECORD P A RC M Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 001 DEF. SUB. 04.05.06 074 PR 055BC 02 -10 -06 083 PR 065BC 03 -08 -06 153 PR 5581 04 -19 -06 PR O J E CT �r t I MILITA I I TEMPERATURE CONTROL MATRIX •t ANALOGIND CL CL z O _ O z Q c� O �' z Z W W O POINTS LIST: z o n Q Q I- a a co x v w REMARKS OUTSIDE AIR DB TEMP 2 X X X NORTHISOUTH CCD 41 OILERS (8-1, B2 AND B-3) CA4 START /STOP C641 3 X OT WATER SUPPLY TEMPERATURE 3 X X EACH BOILER AND HEADER OILER ALARM 3 X X X AIR HANDLING UNIT (AHU 2) CCD 41 SUPPLY FAN STARTISTOP 1 3 X X � � F � 149 150 CCD 026 PR 134 X X V 04.17.06 "� PR 137 A CCD 41 1 z X z 3 X ,'E z SQ 05.11.06 05.17.06 183 05.26.06 1 a X 191 SUPPLY FAN VFD SPEED 1 _ -1 X X X cod CHILLER (CH -1) CCD 41 1 X X 2 fa X START /STOP 1 C1 X X X � % X IL 10 m D OMESTIC WATER HEATER PUMPS (HWP4,2) 2 U W REMARKS ON/OFF STATUS CCD 41 1 X X X START /STOP CWR TEMP i X X X X ( III X X CWS TEMP 1 2 X X X X X X CR TEMP 1 X X X X X X CCD 41 CS TEMP 1 X X X SNOWMELT PUMPS (SMP4,2,3,4) X X X CHILLED WATER FLOW RATE AND PROOF OF FLOVY 1 X X X X X STARTISTOP 4 X DELTA P TRANSMITTER CONDENSER WATER FLOW RATE AND PROOF OF LOW 1 X X X X X P UMP STATUS 4 DELTA P TRANSMITTER CWS BYPASS VALVE 1 X X X X I SOLATION VALVE POSITION CONTROL AND I NDICATION 2 X X X X END SWITCH COOLING CONTROL VALVE 1 X X X COOLING TOWERS (CT -1 AND CT 2) 1 X C HILLED WATER PUMPS (CWP -1, 2) X HARD WIRED AN START /STOP 2 X START /STOP CCD 2 X VFD SPEED 2 X X X X 41 VFD FAILURE 2 X X X 2 CR TEMP 2 X X X X X X X DELTA P CS TEMP 2 X X X X X X CT-5 AND PLANT HEADER SUMP TEMP 1 VFD FAILURE X 2 X X X X NOTE 1 SUMP WATER LEVEL 2 X X PRESSURE DIFFERENTIAL 1 X X X SOLATION VALVE POSITION CONTROL AND NDICATION 2 X X X END SWITCH SUMP MAKE -UP WATER VALVE 1 X X CCD C ONDENSER WATER PUMPS (CP -1,2) WATERSIDE ECONOMIZER PLATE & FRAME HEAT E XCHANGER (HX -1) I SOLATION VALVE POSITION CONTROL AND � I NDICATION CCD 41 2 X X X X END SWITCH CS TEMP 1 X 2 X X CR TEMP 1 X X X CWS TEMP C 41 1 X CWR TEMP 1 X h B LDG WATER HEATING PUMPS (SHWP -1, 2) CCD 41 OILERS (8-1, B2 AND B-3) CA4 START /STOP C641 3 X OT WATER SUPPLY TEMPERATURE 3 X X EACH BOILER AND HEADER OILER ALARM 3 X X X AIR HANDLING UNIT (AHU 2) CCD 41 SUPPLY FAN STARTISTOP 1 3 X X � � F � 149 150 CCD 026 PR 134 X X V 04.17.06 "� PR 137 E XHAUST FAN START /STOP (EF 27) C641 1 z X z 3 X ,'E z SQ 05.11.06 05.17.06 183 05.26.06 1 a X 191 SUPPLY FAN VFD SPEED 1 _ -1 X X X cod SUPPLY FAN VFD FAILURE 1 X X 2 fa X EXHAUST FAN VFD SPEED (EF -27) CCD 41 1 C1 X X � % X IL 10 m D OMESTIC WATER HEATER PUMPS (HWP4,2) 2 U W REMARKS EXHAUST FAN VFD FAILURE (EF 27) 1 X X START /STOP R.A. TEMP 1 X X X X S.A. TEMP 1 2 X X X X .A. TEMP 1 X X X X CCD 41 O.A. DAMPER POSITION 1 X X X SNOWMELT PUMPS (SMP4,2,3,4) X R.A. DAMPER POSITION 1 X X X X STARTISTOP 4 X E .A. DAMPER POSITION 1 X X X P UMP STATUS 4 X 1___ CD 41 C X X EATING CONROL VALVE 1 X X COOLING CONTROL VALVE 1 X X X CCD 41 1 X C HILLED WATER PUMPS (CWP -1, 2) X HARD WIRED AN ISOLATION DAMPER 9 X START /STOP CCD 2 X STAIRWELL DIFF. PRESS. SENSOR 8 X X 41 EXHAUST FANS 8 X LOW RATE 2 FILTER STATUS 1 X X X X X X X DELTA P SMOKE DETECTOR 1 X X X X X STATIC PRESSURE 1 VFD FAILURE X 2 X X X X NOTE 1 AIR FLOW MEASURING STATIONS 2 X X PRESSURE DIFFERENTIAL 1 X FREEZE STAT SAFETY 1 AHU -7 CWS VALVE HARD WIRED ;O OILER PUMPS (PHWP -1,2 AND 3) START /STOP 2 3 E- X � � F � 149 150 CCD 026 PR 134 X X V 04.17.06 "� PR 137 SUPPLY DUCT HIGH LIMIT RELATIVE HUMIDITV ice-• z z P UMP STATUS z 3 X ,'E z SQ 05.11.06 05.17.06 183 05.26.06 1 a X 191 WATER CONTROL VALVE ..11 _ -1 O 0 X cod P UMP STATUS CCD 41 2 X 2 fa POINTS LIST: z C1 4 Q � % I C IL 10 m D OMESTIC WATER HEATER PUMPS (HWP4,2) 2 U W REMARKS BOILER ROOMMAKE -UP AIR UNIT (MAU -9) ITITIES) START /STOP 2 1 X X X X FAN ONIOFF STATUS P UMP STATUS ON 2 X X X DAMPER CONTROL 9 X X CCD 41 S.A. TEMP i X X X SNOWMELT PUMPS (SMP4,2,3,4) X D ISCHARGE AIR TEMP X X STARTISTOP 4 X A X X P UMP STATUS 4 X CCD 41 X X EATING CONTROL VALVE 1 X X CCD 41 9 X FREEZE STAT SAFETY 1 X C HILLED WATER PUMPS (CWP -1, 2) X HARD WIRED AN ISOLATION DAMPER 9 X START /STOP CCD 2 X STAIRWELL DIFF. PRESS. SENSOR 8 X X 41 EXHAUST FANS 8 X LOW RATE 2 START /STOP 36 X X X X VFD SPEED 36 2 X X X VFD FAILURE 2 X X PRESSURE DIFFERENTIAL 1 X M ISCELLANEOUS METER POINTS AHU -7 CWS VALVE TU METER CCD C ONDENSER WATER PUMPS (CP -1,2) 41 STARTISTOP 2 X C 9 N /OFF STATUS 2 X X TOWN SNOWMELT GLYCOL FEEDER LOW 1 X X LEVEL ALARM A h B LDG WATER HEATING PUMPS (SHWP -1, 2) START /STOP 2 X VFD SPEED 2 X X X VFD FAILURE 2 X X PRESSURE DIFFERENTIAL 1 X C 9 SNOW MELT PUMPS (HWP -3,4) START /STOP 2 X LOW RATE 2 X X X CCD 41 VFD SPEED 2 X X X VFD FAILURE 2 X X PRESSURE DIFFERENTIAL 1 X WS /HWR TEMP. 2 X 3 -WAY CONTROL VALVE 1 X DOLING TOWER SUMP FILTER PUMP START /STOP 1 X N /OFF STATUS 1 X X CURRENT SWITCH FILTER CHANGE OUT 1 X X DELTA P D OMESTIC HOT WATER HEATERS W TEMP 1 X X W TEMP 4 X X X X W CIRC TEMP 7 X X ONE PER SYSTEM CC0 4 1 P UMP START /STOP (HWP -1,2, CP -1 THRU CP -7) 9 X P UMP STATUS (HWP -1,2, CP 4 THRU CP -7) 9 X X - 3 -WAY CONTROL VALVE 1 X ( X Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— MSI.DWG — M002.6 PLOT DATE: 05/25/2006 Q 3:35pm REV: 05/25/2006 CAD: hdy XREF: tb —o.dwg tb— smoke— defsubl.dwg tb.dwg tb— condo.dwg TEM PERA TU R E O R O M ATR IX P TYPE I ANALOG • '_ u I,.l /_ u. _. V—'t, lL f o i _ :ail SPACE R.H. 2 � E- � � � F � 149 150 CCD 026 PR 134 X X V 04.17.06 "� PR 137 SUPPLY DUCT HIGH LIMIT RELATIVE HUMIDITV ice-• z z Q z 0 05.10.06 ,'E z SQ 05.11.06 05.17.06 183 05.26.06 1 a 05.26.06 05.26.06 191 WATER CONTROL VALVE ..11 _ -1 O 0 X cod P UMP STATUS CCD 41 2 X 2 fa POINTS LIST: z C1 4 Q � % I C IL 10 m 2 U W REMARKS BOILER ROOMMAKE -UP AIR UNIT (MAU -9) ITITIES) AN STARTISTOP 1 X X X FAN ONIOFF STATUS 1 X X DAMPER CONTROL X X CCD 41 S.A. TEMP i X X X X D ISCHARGE AIR TEMP X X A X X EXCEPT COMMON AREAS CCD 41 EATING CONTROL VALVE 1 X X CCD 41 9 X FREEZE STAT SAFETY 1 X X HARD WIRED AN ISOLATION DAMPER 9 X STAIRWELL DIFF. PRESS. SENSOR 8 X X EXHAUST FANS 8 X NOTES 1, 2 START /STOP 36 X ON /OFF STATUS 36 X X M ISCELLANEOUS METER POINTS TU METER CCD 41 C 9 TOWN SNOWMELT GLYCOL FEEDER LOW 1 X X LEVEL ALARM A h I,.l /_ u. _. V—'t, lL f o i _ :ail SPACE R.H. 2 07.29.05 04.10.06 148 11 X 04.11.06 04. 146 X 04.14.06 149 150 CCD 026 PR 134 X X PR 136 04.17.06 156 PR 137 SUPPLY DUCT HIGH LIMIT RELATIVE HUMIDITV 2 CCD 029 04<26.06 X CCD 031 05.10.06 X ASI144 CCD 033 05.11.06 05.17.06 183 X 05.26.06 189 185 CCD 41 CCD 40 05.26.06 05.26.06 191 WATER CONTROL VALVE 2 X X P UMP STATUS CCD 41 2 X TERMINAL UNITS (REFER TO DWGS FOR QUM ITITIES) SPACE TEMP X X AIR FLOW X DAMPER CONTROL X X REHEAT VALVE X X D ISCHARGE AIR TEMP X X SET POINT ADJUSTMENT X X EXCEPT COMMON AREAS SMOKE MANAGMENT (SMF4 THROUGH SMF-9 AN START /STOP 9 X AN STATUS 9 X X CURRENT SWITCH AN ISOLATION DAMPER 9 X STAIRWELL DIFF. PRESS. SENSOR 8 X X STAIRWELL RELIEF DAMPER 8 X NOTES: 1. PROVIDE LOW LIMIT STATIC SENSOR FOR FANS ABOVE 3000 CFM. SEE DRAWING SCHEDULES FOR QUANTITY. 2. REFER TO DRAWINGS FOR QUANTITY. OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OP RECORD J ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATE$, CO. DENVER, COLORADO CIVILENGINEER ALPINE ENGINEERING, INC. VAU,COLORADO INTERIOR DESIGN SLIDER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 023 147 ADDE 14 ASI126 07.29.05 04.10.06 148 11 PR 124R1 A S I 093 04.11.06 04. 146 CCD 025 04.14.06 149 150 CCD 026 PR 134 04.14.06 04.17.06 154 PR 136 04.17.06 156 PR 137 04.24.06 158 CCD 029 04<26.06 171 CCD 031 05.10.06 173 177 ASI144 CCD 033 05.11.06 05.17.06 183 CCD 033R1 05.26.06 189 185 CCD 41 CCD 40 05.26.06 05.26.06 191 ASI159 05.26.06 RE: INDEX SHEETS FOR PREVIOUS ISSUE LISTINGS MOJ= N PROJECT KEYPLAN MECHANICAL SCHEDULES ffutillim ® 2003 4240 ARCHITECTURE, INC. I I PLUMBING FIXTUR S CHEDULE DESIG. FIXTURE TRAP ` RAP ARM SIZE VENT CW HW REMARKS WC WATER CLOSET 4" f j 2" 1 " - 1/2" CW FOR TANK TYPE UR URINAL 2" 1 1 /2" 3/4" - WEIGHT L LAVATORY 1 1/4" 1 1/2" 1/2 1/2" SIZE S SINK i 1 1/2" ( 1 1/2" 1/2 1/2" 14 MSB MOP SERVICE BASIN 3" I 2" 1/2" 1 /2 11 HWG -3 SH SHOWER 2" 1 1/2" 1/2" 1/2" SERIES 80 IN -LINE ES EMERGENCY SHOWER - - 1 1/4" _ 40 DF /EWC DRINKING FOUNTAIN /ELECTRIC WATER COOLER 1 1/4" 1 1/2" 1/2" - 4810 HB /WH HOSE BIBB AND WALL HYDRANT - - 3/4" - ST -12 WWB WASHER WALL BOX 2" 2" 1/2" 1/2" SEE DETAIL N_ OTES: 1. 2" MINIMUM WASTE AND VENT BELOW GRADE. 2. ALL P- TRAPS, TRAP ARMS, STRAINERS, FLEX TUBES AND ANGLE STOPS ARE FURNISHED AND INSTALLED BY M.C. PUMP SCHEDULE DESIGNATION MANUFACTURER MODEL EXPANSION TANK SCHEDULE SERVICE MAX. OPER. WEIGHT (LB S TANK GPM TANK VOL. PRE-CHARGE OPER, DISCHARGE DESIGNATION MANUFACTURER MODEL VOL. /GAL. MODEL SERVICE PRESSURE WEIGHT REMARKS DYNAMIC EFF. MIN. RPM SIZE SIZE PSIG LBS WW3E +17 DET -1 AMTROL ST -30V -C 14 'F DOMESTIC 40 150 HP 'LOW PRESSURE SYSTEM i HWG -3 Q N. WW3E +20 40 WATER LOW PRESS B & G 1-1/2 X 1-1/2 X 9 -1/2 SERIES 80 IN -LINE DET -2 AMTROL ST -30V -C 14 25 DOMESTIC 40 150 1 1 /2 CONTINUOUS TOWER A 190 138 4810 WATER HIGH PRESS 2 I 80 HIGH PRESSURE SYSTEM DET -3 AMTROL ST -12 4,5 110 DOMESTIC 40 150 CP -2 B& G 1 -1/2 X 1 -1/2 X 9 -1/2 SERIES 80 IN -LINE DOM. HW RECIRC. 120 WATER LOW PRESS. 60 I 20 3 1750 1 1 / 2 1 1 / 2 CONTINUOUS TOWER D S120-1 PUMP SCHEDULE DESIGNATION MANUFACTURER MODEL CAPACITY SERVICE MAX. OPER. WEIGHT (LB S TOTAL GPM TANK VOL. WS -1 SUCTION DISCHARGE 240 _ DESIG. MFR, MODEL PUMP TYPE SERVICE OPER. TEMP GPM DYNAMIC EFF. MIN. RPM SIZE SIZE CONTROL REMARKS WW3E +17 ASI -3 140 77 190 'F 3792 HEAD FT. 9; HP 'LOW PRESSURE SYSTEM i HWG -3 Q N. WW3E +20 40 CP -1 B & G 1-1/2 X 1-1/2 X 9 -1/2 SERIES 80 IN -LINE DOM. HW RECIRC. 120' 17 60 25 3 1750 1 1 /2 1 1 /2 CONTINUOUS TOWER A 190 138 4810 ( 185 2 I 80 HIGH PRESSURE SYSTEM EWH -1 STATE S86 120 6 IFE 40 110 -- -- ALL BRONZE CP -2 B& G 1 -1/2 X 1 -1/2 X 9 -1/2 SERIES 80 IN -LINE DOM. HW RECIRC. 120 12 60 I 20 3 1750 1 1 / 2 1 1 / 2 CONTINUOUS TOWER D ALL BRONZE CP -3 B& G 1 -1/2 X 1 -1/2 X 9 -1/2 SERIES 80 IN -LINE DOM. HW RECIRC. 120 10 60 20 3 1750 1 1 2 / 1 1/2 / CONTINUOUS TOWER B ALL BRONZE CP -4 B &G 1-1/2 X 1-1/2 X 9 -1/2 SERIES 80 IN -LINE DOM. HW RECIRC. 120' 10 60 20 3Q 1750 1 1 /2 1 1/2 CONTINUOUS TOWER C ASI-30 ALL BRONZE CP -5 B & G 1-1/2 X 1-1/2 X 9-1/2 SERIES 80 IN -LINE DOM. HW RECIRC, t 20' 29 55 40 2 1750 1 1 /2 1 1 /2 CONTINUOUS LOWER 120'F ALL BRONZE CP -6 B & G 1-1/2 X 1-1/2 X 7 SERIES 60 IN -LINE DOM. HW RECIRC t 40• 4 45 20 1 -1 /2 1750 1 1 /2 1 1 /2 CONTINUOUS LOWER 140'F ALL BRONZE CP -7 B & G NRF -9F /LW IN -LINE DOM. HW RECIRC 11 2 6 -- 40 WATTS 2800 3/4" 3/4" CONTINUOUS ICE RINK ASI ALL BRONZE SE -1 WEIL 2503 SUBMERS. SEWAGE 80" (2)250 60 53 (2)10 1750 9 4 MERCURY DUPLEX FLOAT ASI -30 SE -2 WEIL 2505 SUBMERS. SEWAGE 80' (2)405 40 55 (2)10 1750 9 4 MFLOATY DUPLEX ASD ASI - 30 ASI - 3 SP -1A WEIL '*_� 530 SUBMERS. SUMP 80• 825 60 63 25 1150 13 6 MERCURY FLOAT SP -18 WEIL 2530 SUBMERS. SUMP 80' 825 60 63 25 1150 13 6 MERCURY FLOAT SP -1C WEIL 2530 SUBMERS. SUMP 80• 825 60 63 25 1150 13 6 MERCURY FLOAT SP -11) I WEIL 2530 SUBMERS. SUMP 80' 825 60 63 25 1150 13 6 MERCURY FLOAT SP -2 WEIL 1405 SUBMERS. ELEVATOR 80' 10 24 -- 1/3 1750 51/4 1 1/4 DIFFERENTIA SUMP FLOAT I WATER SOFTENER SCHED DESIGNATION MANUFACTURER MODEL CAPACITY SERVICE SYSTEM OPER. WEIGHT (LB S REMARKS GPM TANK VOL. WS -1 CULLIGAN HS 2004 / HI -FLO 50E 240 _ DOMESTIC HOT WATER LOW PRESSURE WW3E +17 1 0 WS -2 CULLIGAN HS 2004 / HI -FLO 50E 240 _ DOMESTIC HOT WATER HIGH PRESSURE 30 O HWG -2 AERCO WW3E +17 40 140 77 190 142 3792 O ASME, METER INITIATED, BRINE RECLAIM VATH 60 "0 X 60"TALL TANK. S120-1 HOT WATER HEATER SCHEDULE DESIG. MFR. MODEL SHELL SIDE (DOMESTIC WTR.) TUBE SIDE (BOILER WTR.) HW CIRC. GPM REMARKS EWT LWT GPM EWT LWT MBH GPM MAX. AP HWG -1 AERCO WW3E +17 40 140 77 190 142 3792 158 2 30 LOW PRESSURE SYSTEM HWG -2 AERCO WW3E +17 40 140 77 190 142 3792 158 2 30 'LOW PRESSURE SYSTEM i HWG -3 AERCO WW3E +20 40 140 97 190 138 4810 185 2 80 HIGH PRESSURE SYSTEM HWG -4 AERCO WW3E +20 40 ( 140 97 190 138 4810 ( 185 2 I 80 HIGH PRESSURE SYSTEM EWH -1 STATE S86 120 6 IFE 40 110 -- -- -- -- -- -- 2 1 2 O1 6 KW, 3 ELEMENTS, 109 GPH 0 100 DEGREE RISE FIRST HOUR. �2 PROVIDE DOMESTIC WATER STORAGE TANK, STATE MO. PV- 120 -OORT, 119 GALLONS CAPACITY, GLASS LINED VERTICAL, JACKETED AND FACTORY INSULATED. PROVIDE CP -7 RECIRC PUMP. S458 -2 BAG FILTER SCHEDULE DD PROG 1 04.12.04 003 DD PROG 2 INLET OUTLET FLOW FILTER PRESS. CD PROG SET DESIG. MFR. MODEL HEADER HEADER RATE MATERIAL RATING REMARKS 04.07.05 SIZE SIZE GPM GPM PSIG BF -1 ROSEDALE I M- 6- 30- 5- 6F- 3- 210- S- 8-PB -C 6" 6" 450 POLYPROPYLENE 200 ASME, 304 SS, BUNA COVER GASKETS. 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDENDUM 14 07.29.05 032 25 MICRON 10.20.0 S458 -2 0 Ian, Raw o\o � P pp RE61S c� . o�`ao•,Fo . F . . . Al O WN ERJD EV ELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J ARC,�rt�cruas Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART ( I IOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MI EP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS,COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD FROG. 2 05.27.05 017 CD FROG. 2R 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDENDUM 14 07.29.05 032 ASI -30 10.20.0 ?..zgzcr N =, PROJECT BEYPLAN PLUMBING SCHEDULES Cator, Ruma & Assoc. FILENAME: H: \04119 \01 -09 -05 DRAWINGS \P- MS2.DWG - M002.4 PLOT DATE: 10/06/2005 0 4:38pm REV: 09/30/2005 CAD: KKR XREF: tb.dwg 11 M002o7 Q 2003 4240 ARCHITECTURE, INC. ��o REG /j JGW O �Q o° •e ea�o��� 0 , o 0 \\ k t � s t! I c ! I i I i `\ tt „ bIr i' i i 4 i S i 7 i 2 ?.� i, I ' _ _ - - -- I1 L i LIONSWAFE PLUMBING SITE PLAN N SCALE: NONE TOTAL SITE DEMAND STORM DRAINAGE = 111,000 , 7.71 CFS, 3460 GPM FLAT ROOF AREA - 54,000 SF SLOPED ROFF AREA - 21,000 SF PLAZA AREA - 36,500 SF SANITARY SEWER - 4070 FIXTURE UNITS DOMESTIC WATER = 450 GPM NATURAL GAS = 71,225,000 BTUH INPUT FIRE PROTECTION = 6 FIRE MAIN KEY NOTES Ot 6" FIRE MAIN. 2O 6" WATER MAIN. 3 8" SANITARY SEWER, TOWER "B ", I.E.= 8123' -6 ", 405 GPM, ASI— ® 12" STORM SEWER, 3.06 CFS, I.E.- 8122' -0 ". Q 6" SANITARY SEWER, TOWER "C ", I.E.= 8131' -1 ", 85 GPM. © 8 "SANITARY SEWER, TOWER "D I.E.= 8130' -0 ", 426 GPM. �7 6 "STORM SEWER, TOWER "D ", I.E.- 8132'6 ", 0.31 CFS. ® 8 "STORM SEWER, TOWER "A", .52 CM I.E.= 8122' -6 ", ® 6 "SANITARY SEWER, TOWER "A ", I.E.- 8120' -0", 281 GPM. 1 10 6 "SANITARY SEWER, TOWER "C ", I.E.= 8126 -0 . 72 GPM. 11 15 'STORM DRAIN, PUMP DISCHARGE, 3500 GPM (POSSIBLE), I.E.= 8122' -2 ". 12 8 0 SANITARY SEWER, TOWER "A" AND PUMP DISCHARGE, I.E.- 8108' -9 250 GPM. 13 12"NATURAL GAS SERVICE, 2 PSIG. GENERAL NOTES 1. THIS DRAWING IS SCHEMATIC IN NATURE. REFER TO FULL SIZE DRAWINGS FOR EXACT LOCATIONS. A7 0 f l s V i $ � } t `h F iy7. C€ d x ytt a �t , S f h.Y d rs ya k 0%X`N ER /DEV ELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J w�c�cru� Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NFWELL ENGINEERS, INC AVON. COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO hNTERIOR DESIGN SLIVER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISI DA'I`S 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERNIIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD PROG. 2 05.27.05 017 CD FROG. 2R 07.01.05 019 ADDENDUMi 10 07.07.05 023 ADDENDUM 14 07.29.05 032 ASI -30 1 2D 0 5 C D B A N ? PROJECT KEYPI AN PLUMBING SITE PLAN Cotor, Ruma & Assoc. FILENAME:H: \04119 \01 -09 -05 DRAWINGS \P— PSITE2.DWG — M003 PLOT: 10/06/2005 0 4:35pm REV: 09/30/2005 CAD: KKR XREF: tb.dwg bgsite.dwg PROP— DRAINAGE.dwg bg— gl.dwg o— fp— gl.dwg S— GRID— MATCHLINE.dwg a— cr— gl.dwg bg— g2,dwg a— fp— g2.dwg G2— RAMP.dwg A— CR— G2.dwg GARAGE— LIMITS.dwg Ih— site.dwg xbg— g2— fs5.dwg S— GRID— GARAGE.dwg A— CL— G2.dwg s— grid.dwg xbg —gl— fsl.dwg xbg— gl— fs2.dwg Gl— GONDOLA.dwg A— CL— G1.dwg iii A i' i i 4 i S i 7 i 2 ?.� i, I ' _ _ - - -- I1 L i LIONSWAFE PLUMBING SITE PLAN N SCALE: NONE TOTAL SITE DEMAND STORM DRAINAGE = 111,000 , 7.71 CFS, 3460 GPM FLAT ROOF AREA - 54,000 SF SLOPED ROFF AREA - 21,000 SF PLAZA AREA - 36,500 SF SANITARY SEWER - 4070 FIXTURE UNITS DOMESTIC WATER = 450 GPM NATURAL GAS = 71,225,000 BTUH INPUT FIRE PROTECTION = 6 FIRE MAIN KEY NOTES Ot 6" FIRE MAIN. 2O 6" WATER MAIN. 3 8" SANITARY SEWER, TOWER "B ", I.E.= 8123' -6 ", 405 GPM, ASI— ® 12" STORM SEWER, 3.06 CFS, I.E.- 8122' -0 ". Q 6" SANITARY SEWER, TOWER "C ", I.E.= 8131' -1 ", 85 GPM. © 8 "SANITARY SEWER, TOWER "D I.E.= 8130' -0 ", 426 GPM. �7 6 "STORM SEWER, TOWER "D ", I.E.- 8132'6 ", 0.31 CFS. ® 8 "STORM SEWER, TOWER "A", .52 CM I.E.= 8122' -6 ", ® 6 "SANITARY SEWER, TOWER "A ", I.E.- 8120' -0", 281 GPM. 1 10 6 "SANITARY SEWER, TOWER "C ", I.E.= 8126 -0 . 72 GPM. 11 15 'STORM DRAIN, PUMP DISCHARGE, 3500 GPM (POSSIBLE), I.E.= 8122' -2 ". 12 8 0 SANITARY SEWER, TOWER "A" AND PUMP DISCHARGE, I.E.- 8108' -9 250 GPM. 13 12"NATURAL GAS SERVICE, 2 PSIG. GENERAL NOTES 1. THIS DRAWING IS SCHEMATIC IN NATURE. REFER TO FULL SIZE DRAWINGS FOR EXACT LOCATIONS. A7 0 f l s V i $ � } t `h F iy7. C€ d x ytt a �t , S f h.Y d rs ya k 0%X`N ER /DEV ELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J w�c�cru� Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NFWELL ENGINEERS, INC AVON. COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO hNTERIOR DESIGN SLIVER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISI DA'I`S 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERNIIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD PROG. 2 05.27.05 017 CD FROG. 2R 07.01.05 019 ADDENDUMi 10 07.07.05 023 ADDENDUM 14 07.29.05 032 ASI -30 1 2D 0 5 C D B A N ? PROJECT KEYPI AN PLUMBING SITE PLAN Cotor, Ruma & Assoc. FILENAME:H: \04119 \01 -09 -05 DRAWINGS \P— PSITE2.DWG — M003 PLOT: 10/06/2005 0 4:35pm REV: 09/30/2005 CAD: KKR XREF: tb.dwg bgsite.dwg PROP— DRAINAGE.dwg bg— gl.dwg o— fp— gl.dwg S— GRID— MATCHLINE.dwg a— cr— gl.dwg bg— g2,dwg a— fp— g2.dwg G2— RAMP.dwg A— CR— G2.dwg GARAGE— LIMITS.dwg Ih— site.dwg xbg— g2— fs5.dwg S— GRID— GARAGE.dwg A— CL— G2.dwg s— grid.dwg xbg —gl— fsl.dwg xbg— gl— fs2.dwg Gl— GONDOLA.dwg A— CL— G1.dwg iii i } t(j) i 77 i i i i i I ' I 1 �r 1 t : , 1 ! MAN -R1 _" �_t.7 r _- _ -__ -� 1 I I 1 1 I EXCHANGER IN 80II.ER 1 F ROOM, SEE M210.2C I 2 P ®., MA 0 1 rul AN -R LJONSHEAD CENTER _ -- - - - - -- ° i _ _ - - - - MAN -T16 1800 9 245 140 115 18.9 220 26 MAN -T22 2 2000 1 SUPPLYfRETURH C✓RM TAP 245 1 140 1 115 2 REFER TO SCHEDULE I 26 +..,zzLLx FOR QUANTITY I 5YS - _ ------------------ . -------------------- --------------------- - - - - -- ---- --- -- -- - - - - -° - i �� ° ° - r' - MAN -T16 NOT USED TOWN OFF VAIL MANIFOLD DETAIL - PLAN VIEW SCALE: NONE A4A AA. uAMFa.o By oTT+ERs MAN -T23 2 2000 1 10 2 245 1 140 1 115 2 21 2 244 2 26 1. SNOW MELT CONTROLS SHALL BE A SINGLE TEKMAR CONTROLLER FOR THE MAN -T24 N NOT USED R C D D029 C S A"_Y/%EA RN dRCUIT 7AP 9 C CCDO29 1 MAN -T17 2400 12 245 140 115 25.2 293 26 SENSOR ON THE NORTHWEST SIDE OF EACH SYSTEM. PROVIDE TWO SPARE MAN -T25 N X_ Z I- L_ Tt SCHEDULE �+n IIM C1 L SENSORS AND CONDUITS FOR EACH SYSTEM LOCATED IN ALTERNATE Sw �, _1 POOR LOCATION. MAN T26 2 2383 1 SmS MAN T18 2400 12 245 140 115 25.2. 293 ' . 26 �J� PLAN KE Y : BALAMM VAL* : REFER TO PLAN MAN -T19 2200 11 245 140, 115 23.1 269 26 FOR SZES . I -50HT MANIFOLD DETAIL MAN -T20 2400 12 245 140 115 25.2 293 26 P AN VIEW MAN T21 1800 9 245 140 115 18.9 220 26 SCALE: NONE A 12 24 1 5 40 115 25.2 293 26 NOTE 3 2_ REFER TO THE 1 SCALE UPPER LEVEL GARAGE PLANS (DRAWINGS M210.2A THROUGH M210.20 AND M400.1) FOR THE SNOW MELT SUPPLY AND RETURN MAN-T27 BELOW THE PLAZA. 27 1400 7 245 140 115 14.7 171 26 C 9 3. FURNISH AND INSTALL BUBBLE /FOIL /BUBBLE INSULATION (ULTRA CBF) 47912 =499.758 5639 MANUFACTURED BY TVM BUILDING PRODUCTS, INC. UNDER ALL TOWN OF VAIL SNOWMELT_ NOTES: 1. ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 3. MANIFOLD SHALL BE INSTALLED NOW, CIRCUIT PIPING SHALL BE ADDED IN 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. THE FUTURE. 4. PROVIDE CAPPED CIRCUITS IN MANIFOLD TO ALLOW FUTURE EXTENSION TO SNOW MELT STAIRS & SIDE WALK TO CONCERT HALL CONDOMINIUMS SNOWMELT Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT\ CAD \DDS \MECH \P- MSITE- SNOWMELT.DWG _ M004 PLOT: 05/25/2006 4 3: 48pm REV: 05/25/2006 CAD: lisol XREF: tb.dwg bgsite.dwg tb -o.dwg Ih- dimension.dwg Ih- groding.dwg Ih- poving.dwg GARAGE- LIMITS.dwg Ih- site.dwg xbgsite- TOV.dwg dhm- NO- Melt.dwg no SNWMLT AREA UTILS.dwg xbgsite -plozo inlets.dwg LH -CORE- PROPLINE.dwg rte ' e \ SNOW MELT ZONE SCHEDULE - RESORT AVERAGE MANIFOLD MAXIMUM MANIFOLD APPROXIMATE NUMBER OF LENGTH PER EWT LWT FLOW RATE MSH PRESSURE REMARKS AREA (SO.FT.) CIRCUITS CIRCUIT ( +F) { +F} GPM DROP (FI) MAN.R1 600 3 245 140 115 6.3 73 26 MAN14U 2400 12 245 140 115 252 293 26 MANiR3 2400 12 245 140 115 25.2 293 26 MAN-R4 2400 12 245 140 115 252 293 26 MAN415 2400 12 245 140 115 25.2 293 26 MANAIN 2700 14 245 140 116 29A 342 26 MAN-R7 1066 6 245 140 115 12.6 146 26 MAN4R8 2800 14 245 140 115 29A 342 26 MAN4t9 1990 10 245 140 115 21 244 26 MAN -RIO 2000 10 245 140 115 21 244 26 MAN -1111 2200 11 245 140 115 23.1 269 26 MAN -R12 2400 12 245 140 115 25.2 293 26 MAN4R13 2400 12 245 140 115 25.2 293 26 MAN.1114 2000 10 245 140 115 21 244 26 MAN -R15 1800 9 E CDOW5 140 115 1819 220 CD029h MAN -R16 1000 5 245 140 115 10.5 122 26 MAN -RI7 800 4 245 140 115 8.4 98 26 f MAN -R18 2000 10 245 140 115 21 244 26 MAN -R19 1800 9 245 140 115 18.9 220 26 MAN -R20 600 3 245 140 115 6.3 73 26 MAN -1121 600 3 245 140 115 6.3 73 26 MAN4t22 400 2 245 140 115 4.2 49 26 MIAN­R23 2400 12 245 140 115 252 293 26 MAN4R24 2000 10 245 140 115 21 244 26 MAN4R25 1800 9 245 140 115 18.9 220 26 MAN -1126 1800 9 245 140 115 1819 220 26 MAN -1127 1200 6 245 140 115 12.6 146 26 MAN-R28 1600 8 245 140 115 16.8 195 26 MAN4t29 1800 9 245 140 115 18.9 220 26 MAN -R30 2000 10 245 140 115 21 244 26 MAN -1131 2400 12 245 140 115 25.2 293 26 MAN 41132 2400 12 245 140 115 252 293 26 MAN -1133 2400 12 245 140 115 252 293 26 MAN -1134 2400 12 245 140 115 252 293 26 MAN -1135 1800 9 245 140 115 18.9 220 26 M4N -R36 1800 9 245 140 115 18.9 220 26 MAN-R37 2400 12 245 140 115 252 293 26 MAN -1138 2188 11 245 140 115 2&0 267 26 MAN -1139 2400 12 245 140 115 252 293 26 MAN,R4O 2400 12 245 140 115 252 293 26 MAN -R41 1600 8 245 140 115 16.8 195 26 MAN -1142 800 4 245 140 115 8.4 98 26 SEE M217.B MAN -1243 2600 13 245 140 115 27.3 317 26 SEg 14.8 MAN -R44 1800 4 245 140 115 18.9 220 26 SEE M212.S MAN -R45 1000 5 245 140 115 10.5 122 26 SEE M216.A MAN -1146 1400 7 245 140 115 14.7 171 26 SEE M210.2S MAN -1147 2105 11 245 140 115 22.1 257 26 MAN -R48 2040 10 245 140 115 21.4 249 26 89288 I 940 10929 N OTES* ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. SNOWMEL OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD F , C' ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK i STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGIN MERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 02 ADDENDUM 14 0 147 ASI 126 04.10.06 10 ,Rii 12481 bkl:ftw 119 ASI093 04.11.06 146 CCD 025 04.14.06 149 CCD 026 04.14.06 150 PR 134 04.17.06 154 PR 136 04.17.06 156 PR 137 04.24.06 158 CCD 029 04.26.06 171 CCD 031 05.10.06 173 ASI144 05.11.06 177 CCD 033 05.17.06 183 CCD 033R1 05.26.06 189 CCD 41 05.26.06 185 CCD 40 05.26.06 191 ASI159 05.26.06 i i RE. INDEX SHEETS FOR PREVIOUS ISSUE L ISTINGS SNOW MELT SITE P LA N «gym PROMWE LNE -SIZE. FLU PM BALL VALVE, CAPABLE � FUG ELLCI W A I MAMW 8Y OTHINS MAN -T22 2 2000 1 SUPPLYfRETURH C✓RM TAP 245 1 140 1 115 2 REFER TO SCHEDULE I 26 +..,zzLLx FOR QUANTITY I 5YS 8ALNY.'NC YALE IOU F Sim TOWN OFF VAIL MANIFOLD DETAIL - PLAN VIEW SCALE: NONE A4A AA. 12 24 1 5 40 115 25.2 293 26 NOTE 3 2_ REFER TO THE 1 SCALE UPPER LEVEL GARAGE PLANS (DRAWINGS M210.2A THROUGH M210.20 AND M400.1) FOR THE SNOW MELT SUPPLY AND RETURN MAN-T27 BELOW THE PLAZA. 27 1400 7 245 140 115 14.7 171 26 C 9 3. FURNISH AND INSTALL BUBBLE /FOIL /BUBBLE INSULATION (ULTRA CBF) 47912 =499.758 5639 MANUFACTURED BY TVM BUILDING PRODUCTS, INC. UNDER ALL TOWN OF VAIL SNOWMELT_ NOTES: 1. ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 3. MANIFOLD SHALL BE INSTALLED NOW, CIRCUIT PIPING SHALL BE ADDED IN 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. THE FUTURE. 4. PROVIDE CAPPED CIRCUITS IN MANIFOLD TO ALLOW FUTURE EXTENSION TO SNOW MELT STAIRS & SIDE WALK TO CONCERT HALL CONDOMINIUMS SNOWMELT Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT\ CAD \DDS \MECH \P- MSITE- SNOWMELT.DWG _ M004 PLOT: 05/25/2006 4 3: 48pm REV: 05/25/2006 CAD: lisol XREF: tb.dwg bgsite.dwg tb -o.dwg Ih- dimension.dwg Ih- groding.dwg Ih- poving.dwg GARAGE- LIMITS.dwg Ih- site.dwg xbgsite- TOV.dwg dhm- NO- Melt.dwg no SNWMLT AREA UTILS.dwg xbgsite -plozo inlets.dwg LH -CORE- PROPLINE.dwg rte ' e \ SNOW MELT ZONE SCHEDULE - RESORT AVERAGE MANIFOLD MAXIMUM MANIFOLD APPROXIMATE NUMBER OF LENGTH PER EWT LWT FLOW RATE MSH PRESSURE REMARKS AREA (SO.FT.) CIRCUITS CIRCUIT ( +F) { +F} GPM DROP (FI) MAN.R1 600 3 245 140 115 6.3 73 26 MAN14U 2400 12 245 140 115 252 293 26 MANiR3 2400 12 245 140 115 25.2 293 26 MAN-R4 2400 12 245 140 115 252 293 26 MAN415 2400 12 245 140 115 25.2 293 26 MANAIN 2700 14 245 140 116 29A 342 26 MAN-R7 1066 6 245 140 115 12.6 146 26 MAN4R8 2800 14 245 140 115 29A 342 26 MAN4t9 1990 10 245 140 115 21 244 26 MAN -RIO 2000 10 245 140 115 21 244 26 MAN -1111 2200 11 245 140 115 23.1 269 26 MAN -R12 2400 12 245 140 115 25.2 293 26 MAN4R13 2400 12 245 140 115 25.2 293 26 MAN.1114 2000 10 245 140 115 21 244 26 MAN -R15 1800 9 E CDOW5 140 115 1819 220 CD029h MAN -R16 1000 5 245 140 115 10.5 122 26 MAN -RI7 800 4 245 140 115 8.4 98 26 f MAN -R18 2000 10 245 140 115 21 244 26 MAN -R19 1800 9 245 140 115 18.9 220 26 MAN -R20 600 3 245 140 115 6.3 73 26 MAN -1121 600 3 245 140 115 6.3 73 26 MAN4t22 400 2 245 140 115 4.2 49 26 MIAN­R23 2400 12 245 140 115 252 293 26 MAN4R24 2000 10 245 140 115 21 244 26 MAN4R25 1800 9 245 140 115 18.9 220 26 MAN -1126 1800 9 245 140 115 1819 220 26 MAN -1127 1200 6 245 140 115 12.6 146 26 MAN-R28 1600 8 245 140 115 16.8 195 26 MAN4t29 1800 9 245 140 115 18.9 220 26 MAN -R30 2000 10 245 140 115 21 244 26 MAN -1131 2400 12 245 140 115 25.2 293 26 MAN 41132 2400 12 245 140 115 252 293 26 MAN -1133 2400 12 245 140 115 252 293 26 MAN -1134 2400 12 245 140 115 252 293 26 MAN -1135 1800 9 245 140 115 18.9 220 26 M4N -R36 1800 9 245 140 115 18.9 220 26 MAN-R37 2400 12 245 140 115 252 293 26 MAN -1138 2188 11 245 140 115 2&0 267 26 MAN -1139 2400 12 245 140 115 252 293 26 MAN,R4O 2400 12 245 140 115 252 293 26 MAN -R41 1600 8 245 140 115 16.8 195 26 MAN -1142 800 4 245 140 115 8.4 98 26 SEE M217.B MAN -1243 2600 13 245 140 115 27.3 317 26 SEg 14.8 MAN -R44 1800 4 245 140 115 18.9 220 26 SEE M212.S MAN -R45 1000 5 245 140 115 10.5 122 26 SEE M216.A MAN -1146 1400 7 245 140 115 14.7 171 26 SEE M210.2S MAN -1147 2105 11 245 140 115 22.1 257 26 MAN -R48 2040 10 245 140 115 21.4 249 26 89288 I 940 10929 N OTES* ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. SNOWMEL OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD F , C' ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK i STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGIN MERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 02 ADDENDUM 14 0 147 ASI 126 04.10.06 10 ,Rii 12481 bkl:ftw 119 ASI093 04.11.06 146 CCD 025 04.14.06 149 CCD 026 04.14.06 150 PR 134 04.17.06 154 PR 136 04.17.06 156 PR 137 04.24.06 158 CCD 029 04.26.06 171 CCD 031 05.10.06 173 ASI144 05.11.06 177 CCD 033 05.17.06 183 CCD 033R1 05.26.06 189 CCD 41 05.26.06 185 CCD 40 05.26.06 191 ASI159 05.26.06 i i RE. INDEX SHEETS FOR PREVIOUS ISSUE L ISTINGS SNOW MELT SITE P LA N «gym MAN -T22 2 2000 1 10 2 245 1 140 1 115 2 21 2 244 2 26 GENERAL NOTES: 44 I I Z Z 114 G MAN -T23 2 2000 1 10 2 245 1 140 1 115 2 21 2 244 2 26 1. SNOW MELT CONTROLS SHALL BE A SINGLE TEKMAR CONTROLLER FOR THE MAN -T24 N NOT USED R C D D029 C CCDO 9 9 C CCDO29 1 SENSOR ON THE NORTHWEST SIDE OF EACH SYSTEM. PROVIDE TWO SPARE MAN -T25 N NOT USED C C1 L SENSORS AND CONDUITS FOR EACH SYSTEM LOCATED IN ALTERNATE POOR LOCATION. MAN T26 2 2383 1 5 40 115 25.2 293 26 NOTE 3 2_ REFER TO THE 1 SCALE UPPER LEVEL GARAGE PLANS (DRAWINGS M210.2A THROUGH M210.20 AND M400.1) FOR THE SNOW MELT SUPPLY AND RETURN MAN-T27 BELOW THE PLAZA. 27 1400 7 245 140 115 14.7 171 26 C 9 3. FURNISH AND INSTALL BUBBLE /FOIL /BUBBLE INSULATION (ULTRA CBF) 47912 =499.758 5639 MANUFACTURED BY TVM BUILDING PRODUCTS, INC. UNDER ALL TOWN OF VAIL SNOWMELT_ NOTES: 1. ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 3. MANIFOLD SHALL BE INSTALLED NOW, CIRCUIT PIPING SHALL BE ADDED IN 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. THE FUTURE. 4. PROVIDE CAPPED CIRCUITS IN MANIFOLD TO ALLOW FUTURE EXTENSION TO SNOW MELT STAIRS & SIDE WALK TO CONCERT HALL CONDOMINIUMS SNOWMELT Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT\ CAD \DDS \MECH \P- MSITE- SNOWMELT.DWG _ M004 PLOT: 05/25/2006 4 3: 48pm REV: 05/25/2006 CAD: lisol XREF: tb.dwg bgsite.dwg tb -o.dwg Ih- dimension.dwg Ih- groding.dwg Ih- poving.dwg GARAGE- LIMITS.dwg Ih- site.dwg xbgsite- TOV.dwg dhm- NO- Melt.dwg no SNWMLT AREA UTILS.dwg xbgsite -plozo inlets.dwg LH -CORE- PROPLINE.dwg rte ' e \ SNOW MELT ZONE SCHEDULE - RESORT AVERAGE MANIFOLD MAXIMUM MANIFOLD APPROXIMATE NUMBER OF LENGTH PER EWT LWT FLOW RATE MSH PRESSURE REMARKS AREA (SO.FT.) CIRCUITS CIRCUIT ( +F) { +F} GPM DROP (FI) MAN.R1 600 3 245 140 115 6.3 73 26 MAN14U 2400 12 245 140 115 252 293 26 MANiR3 2400 12 245 140 115 25.2 293 26 MAN-R4 2400 12 245 140 115 252 293 26 MAN415 2400 12 245 140 115 25.2 293 26 MANAIN 2700 14 245 140 116 29A 342 26 MAN-R7 1066 6 245 140 115 12.6 146 26 MAN4R8 2800 14 245 140 115 29A 342 26 MAN4t9 1990 10 245 140 115 21 244 26 MAN -RIO 2000 10 245 140 115 21 244 26 MAN -1111 2200 11 245 140 115 23.1 269 26 MAN -R12 2400 12 245 140 115 25.2 293 26 MAN4R13 2400 12 245 140 115 25.2 293 26 MAN.1114 2000 10 245 140 115 21 244 26 MAN -R15 1800 9 E CDOW5 140 115 1819 220 CD029h MAN -R16 1000 5 245 140 115 10.5 122 26 MAN -RI7 800 4 245 140 115 8.4 98 26 f MAN -R18 2000 10 245 140 115 21 244 26 MAN -R19 1800 9 245 140 115 18.9 220 26 MAN -R20 600 3 245 140 115 6.3 73 26 MAN -1121 600 3 245 140 115 6.3 73 26 MAN4t22 400 2 245 140 115 4.2 49 26 MIAN­R23 2400 12 245 140 115 252 293 26 MAN4R24 2000 10 245 140 115 21 244 26 MAN4R25 1800 9 245 140 115 18.9 220 26 MAN -1126 1800 9 245 140 115 1819 220 26 MAN -1127 1200 6 245 140 115 12.6 146 26 MAN-R28 1600 8 245 140 115 16.8 195 26 MAN4t29 1800 9 245 140 115 18.9 220 26 MAN -R30 2000 10 245 140 115 21 244 26 MAN -1131 2400 12 245 140 115 25.2 293 26 MAN 41132 2400 12 245 140 115 252 293 26 MAN -1133 2400 12 245 140 115 252 293 26 MAN -1134 2400 12 245 140 115 252 293 26 MAN -1135 1800 9 245 140 115 18.9 220 26 M4N -R36 1800 9 245 140 115 18.9 220 26 MAN-R37 2400 12 245 140 115 252 293 26 MAN -1138 2188 11 245 140 115 2&0 267 26 MAN -1139 2400 12 245 140 115 252 293 26 MAN,R4O 2400 12 245 140 115 252 293 26 MAN -R41 1600 8 245 140 115 16.8 195 26 MAN -1142 800 4 245 140 115 8.4 98 26 SEE M217.B MAN -1243 2600 13 245 140 115 27.3 317 26 SEg 14.8 MAN -R44 1800 4 245 140 115 18.9 220 26 SEE M212.S MAN -R45 1000 5 245 140 115 10.5 122 26 SEE M216.A MAN -1146 1400 7 245 140 115 14.7 171 26 SEE M210.2S MAN -1147 2105 11 245 140 115 22.1 257 26 MAN -R48 2040 10 245 140 115 21.4 249 26 89288 I 940 10929 N OTES* ALL ZONES HAVE 5/8" TUBING SPACED 10" ON CENTER. 2. FLOW RATE PER CIRCUIT IS 2.1 GPM. SNOWMEL OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD F , C' ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK i STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGIN MERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 02 ADDENDUM 14 0 147 ASI 126 04.10.06 10 ,Rii 12481 bkl:ftw 119 ASI093 04.11.06 146 CCD 025 04.14.06 149 CCD 026 04.14.06 150 PR 134 04.17.06 154 PR 136 04.17.06 156 PR 137 04.24.06 158 CCD 029 04.26.06 171 CCD 031 05.10.06 173 ASI144 05.11.06 177 CCD 033 05.17.06 183 CCD 033R1 05.26.06 189 CCD 41 05.26.06 185 CCD 40 05.26.06 191 ASI159 05.26.06 i i RE. INDEX SHEETS FOR PREVIOUS ISSUE L ISTINGS SNOW MELT SITE P LA N «gym OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD F , C' ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK i STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGIN MERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 02 ADDENDUM 14 0 147 ASI 126 04.10.06 10 ,Rii 12481 bkl:ftw 119 ASI093 04.11.06 146 CCD 025 04.14.06 149 CCD 026 04.14.06 150 PR 134 04.17.06 154 PR 136 04.17.06 156 PR 137 04.24.06 158 CCD 029 04.26.06 171 CCD 031 05.10.06 173 ASI144 05.11.06 177 CCD 033 05.17.06 183 CCD 033R1 05.26.06 189 CCD 41 05.26.06 185 CCD 40 05.26.06 191 ASI159 05.26.06 i i RE. INDEX SHEETS FOR PREVIOUS ISSUE L ISTINGS SNOW MELT SITE P LA N «gym RE. INDEX SHEETS FOR PREVIOUS ISSUE L ISTINGS SNOW MELT SITE P LA N «gym © 2003 42 ARCHITECTURE, INC. E AREA D = m � m E( E AREA A KEY NOTES: T ALL KEY N S OF PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION IN A BREAK —GLASS TYPE ENCLOSURE PROVIDING ON —ONLY CONTROL. 0 PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF —ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. 3 PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND SYSTEMS. O ��UO R E G, ST� o �, °��GLAS yo • •F� 3496:8 n> A V yj_ N4� O� OWNER/DEVELOPER VAIL RESORTS COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART ( HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE U,U I- I- <t <t LOWER LEVEL GARAGE - HVAC PLAN - AREA A p SCALE:1 8 =1' -0" e 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 HVAC PLAN i LOWER LEVEL GARAGE AREA A Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- HVNG2.DWG - M1101A PLOT: 04/27/2005 @ 8:08am REV: 04/27/2005 CAD: morlone XREF: HVNG2.dwg tb.dwg xbg1- usc.dwg bg- g2.dwg o- fp- g2.dwg A- CR- G2.dwg G2- RAMP.dwg kpion- go.dwg kpion- gb.dwg kpion- gc.dwg kpion - gd.dwg S- GRID- MATCHUNE.dwg pwrg2.dwg elecg2.dwg Iii 1 10 Q 2oos 4214o ARCHREC7URE, INC. I I 21mr o� GAR LOWER LEVEL HV PL/-kN - ♦ / ♦ 1 ;. INE AREA 1 AREA 1 1 — tiD — — ---<D Cator, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG2.DWG — M110.1A PLOT: 04/04/2006 0 1:00pm REV-. 04/03/2006 CAD: christina XREF: HVNG2.dwg tb.dwg xbgl— use.dwg bg— g2.dwg a— fp— g2.dwg A— CR— G2.dwg G2— RAMP.dwg kplan—go.dwg kplan — gb.dwg kpion— gc.dwg kplan—gd.dwg S— GRID— MATCHLINE.dwg xbg— g2— fs5.dwg S— GRID— GARAGE.dwg tb —a.dwg tb— smoke— defsubl.dwg tb— llX17.dwg pwrg2.dwg elecg2.dwg N OT # TO THIS S PROVIDE CLEARLY ra ar SWIT F OR EMERGENCY -r E VENMILATI # IN A BREAK-MASS TYPE ENCLOSURE PROVIDING ON-ONLY CONTROL PROVIDE CLEARLY I DENTIFIED SWIT OF CLASS TYPE PROVID OFF—O OFF—ONLY CONTROL OF ELECTRICALLY ENER GIZED EQUIPM VATHI THE R EF RI GERANT M k a• R • CATE SWITCHES IMM EDIATE LY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EAT. P ROVIDE "i ar EM ERGENCY S CHARTS i • ACC ORD AN WITH THE INT ERNATIONAL CODE # • REFRI r S� AIITA & OWNER /DEVELOPER V AIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD IO U Denver, Colorado MASTERPLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURALENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER 20826.01 ISSUE REVISION DATE 001 DER SUB. 04.05.06 HVAC PLAN LOWER LEVEL GARAGE AREA A" GSif[1�i /1 f4 16 18 20 f 25 26 1 I i I T F © 2003 42140 ARCHITECTURE, INC. MATC H -- -- MATC H 24/20 DROP ALONG WALL TERMINATE DUCT 1' A.F.F WITH 1/4 MESH SCREEN OPENING. (TYP) KEY NOTES: ALL KEY N S �j PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATON IN A BREAK —GLASS TYPE ENCLOSURE PROVIDING ON —ONLY CONTROL. O PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF —ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. /7\ PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE V WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND i p REGI, LAS y ;pFO 0 N At OWNER/DEVELOPER REFI SEN AND EQU OPE VAIL RESORTS n fTX TR T CIT)'N M' N7T` LL V l 't .1J \J1 1.v.1111 N A COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART ( HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE LOWER LEVEL GARAGE - HVAC PLAN - AREA B b SCALE: 1/8"=V-0" Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG2.DWG — M110.18 PLOT: 04/27/2005 0 8:07om REV: 04/27/2005 CAD: morlone XREF: HVNG2.dwg tb.dwg xbg1— usc.dwg bg— g2.dwg o— fp- 92.dwg A— CR— G2.dwg G2— RAMP.dwg kplon— go.dwg kpion— gb.dwg kplon— gc.dwg kplon— gd.dwg S— GRID— MATCHLINE.dwg pwrg2.dwg elecg2.dwg A 002 DD PROG 1 Ulu DD PROG 2 05.21.04 Q Q 06.21.04 005 LOWER LEVEL GARAGE - HVAC PLAN - AREA B b SCALE: 1/8"=V-0" Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG2.DWG — M110.18 PLOT: 04/27/2005 0 8:07om REV: 04/27/2005 CAD: morlone XREF: HVNG2.dwg tb.dwg xbg1— usc.dwg bg— g2.dwg o— fp- 92.dwg A— CR— G2.dwg G2— RAMP.dwg kplon— go.dwg kpion— gb.dwg kplon— gc.dwg kplon— gd.dwg S— GRID— MATCHLINE.dwg pwrg2.dwg elecg2.dwg A 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 KEY NOTES: T ALL KEY N S �j PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATIOD IN A BREAK -GLASS TYPE ENCLOSURE PROVIDING ON -ONLY CONTROL. O PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF -ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. (� PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND , © 2003 42140 ARCHITECTURE, INC. R E o 6 i I OWNER/DEVELOPER VAIL RESORTS nTF'NTRT (IT)ATUXT'r 1./ V 1_J11 V 1 a.ItLJl N 1 COMPANY AVON, COLORADO ARCHITECT OF RECORD 1 ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER. COLORADO CIVIL ENGINEER ALPINE. ENGINEERING, INC. VAIL, COLORADO IN'IERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE AN 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PER:tiIIT /BID I 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 I I I I i HVAC PLAN LOWER LEVEL GARAGE AREA C Cotor, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG2.DWG — M1101C PLOT: 04/27/2005 ®8:07am REV: 04/27/2005 CAD: morlone XREF: HVNG2.dwg tb.dwg xbg1— usc.dwg bg— g2.dwg a— fp— g2.dwg A— CR— G2.dwg G2— RAMP.dwg kplon — ga.dwg kplon—gb.dwg kplon— gc.dwg kplon gd.dwg S— GRID — MATCHUNE.dwg pwrg2.dwg elecg2.dwg M110.1c Q 2003 42140 ARCHITECTURE, INC. . • 1, # 9 2 z N w•kii VM; Wn It) I MID, k' Mir? I WAW#. z I IN01 m ia� PROVIDE APPROVED EMERGENCY SIGNS� CHARTS, AND LABLES IN ACCORDANCE VATH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UN17S AND SYSTEMS. OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD "* XA AR.CHrM"1 1 Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORI NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUIN AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC, VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER- 20826.01 Cator, Ruma & Assoc. FILENAME:P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P—HVNG2.DWG — M110.1C PLOT. 04/04/2006 01:01pm REV. 04/03/2006 CAD: christina XREF. HVNG2.dwg tb.dwg xbgl—uso.dwg bg—g2.dwg a—fp—g2.dwg A—CR—G2.dwg G2—RAMP.dwg kpion—ga.dwg kplan—gb.dwg kpIan—gc.dwg kplan—gd.dwg S—GRID—MATCHLINE.dwg xbg—g2—fs5.dwg S—GRID—GARAGE.dwg tb—a.dwg tb—smoke—defsubl.dwg tb—llX17.dwg pwrg2.dwg eleag2.dwg h , lu"A'm FV 1800 �F-�ZMP J Li Mg 2 3 2006 ISSUE REVISION DATE 001 DEF. SUB. 04-05-06 T T © 2003 4240 ARCHITECTURE, INC. KEY NOTES. ALL KEY N S Oj PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION IN A BREAK -GLASS TYPE ENCLOSURE PROVIDING ON -ONLY CONTROL. O PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF -ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. (T\ PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE V WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND i IS ° OF 56" 5' -8" -368 s fOW 7�z 7 05 OWNER /DEVELOPER VAIL RESORTS T TR'_XF T n13Ajf1:7NT Av v u uvi 1rilJ1 v t COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCf1ITECi' HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUIViBER: 20826.01 ISSUE REVISION DATE + LOWER LEVEL GARAGE - HVAC PLAN - AREA D, N E AREA D E AR EA A R e 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERNET /BID 02.15.05 007 PERTNET REV 03.24.05 008 PERTMIT REV 04.07.05 HVAC LOWER GARAGE PLAN LEVEL AREA D M110.1D Cotor, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG2.DWG — M110.1D PLOT: 04/27/2005 @ 8:07om REV: 04/27/2005 CAD: morlone XREF: HVNG2.dwg tb.dwg xbgl — usc.dwg bg— g2.dwg o— fp— g2.dwg A— CR— G2.dwg G2— RAMP.dwg kpion— go.dwg kpion— gb.dwg kplon— gc.dwg kplon — gd.dwg S— GRID — MATCHLINE.dwg pwrg2.dwg elecg2.dwg 7YFF ERS 02 0 1 50 250 1 12X6 i 1 1 I e UH m 1Q MGMT. LOCKERS & SKI STORAGE TUNNEL G104 UPPER LEVEL GARAGE - HVAC PLAN - AREA A wj SCALE: 1 /8 =1 -0 Cator, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNG1.DWG — M110.2A PLOT: 04/27/2005 ®7:53om REV: 04/27/2005 CAD: morlone XREF: HVNG1.dwg tb.dwg bg— gl.dwg a— fp— gl.dwg a— cr— gi.dwg xbgl— usc.dwg kplon— gb.dwg kplan— gb.dwg kpion — gd.dwg S— GRID — MATCHLINE.dwg tb —o.dwg xbg— gl— loundry.dwg elecgl.dwg i LINE AREA D -- - - -•• - I LINE AREA A KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET Q GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. Q LOUVER IS LOCATED BELOW ESCALATORS ON FLOOR ABOVE. J PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION /- IN A BREAK -GLASS TYPE ENCLOSURE PROVIDING ON -ONLY CONTROL. Q PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF -ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND YSTEMS. e © 2003 42140 ARCHITECTURE, INC. i �-r OWNER/DEVELOPER VAIL RESORTS TII--T TIC !lT)A fiT, T'Tf 1JL V L' ! .V1`1VLL.1V t COMPANY AVON,COLORADO ARCHITECT OF RECORD ■ J AACHITEGTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR RUMA AND ASSOCIATES, CO. DEiW ER, COLORADO CIVIL ENGINTFFR ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUNMER: 20826.01 ISSUE REVISION DATE HVAC PLAN UPPER LEVEL GARAGE AREA A M1 10.2A 002 DD PROG 1 04.12.04 003 Db PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 MATCH MATC H KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET Q GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. O LOUVER IS LOCATED BELOW ESCALATORS ON FLOOR ABOVE. YS) PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION IN A BREAK —GLASS TYPE ENCLOSURE PROVIDING ON —ONLY CONTROL. O PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF —ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT/DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND © 2003 42140 ARCHITECTURE, INC. /S� 496 m to NAt OWNER /DEVELOPER VAIL RESORTS nF.VF.T .QPIUTF.NT COMPANY AVON,COLORADO ARCHITECT OF RECORD ■ J Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE UPPER LEVEL GARAGE - HVAC PLAN - AREA B (v� SCALE: 1/8 ° =1' -0 Cator, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- HVNG1.DWG - M110.2B PLOT: 04/27/2005 ®7:52om REV: 04/27/2005 CAD: morlone XREF: HVNG1.dwg tb.dwg bg- gl.dwg a- fp- gl.dwg a- cr- gl.dwg xbgl- usc.dwg kplon- go.dwg kplan- gb.dwg kplon- gd.dwg S ° GRID- MATCHLINE.dwg tb -o.dwg xbg- 91- loundry.dwg elecgl.dwg m,Q Q Q W W ry ry Q Q L1� W z z Ulu Q Q e 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERIIIIT REV 04.07.05 HVAC PLAN UPPER LEVEL GARAGE AREA B M1 10.2B o tow 42140 ARcHrrmuim INC. e MATCH m m M M ATCH KITCHEN HOOD SIZING, FIRE SU` AND CLEARANCES ARE THE RESPONSIBILITY OF THE KITOiEK CONSULTANT AND WLL APPEAR KITCHEN PLANS 70 BE SUBMITE; 0 7 ------ ------ ------ DA UPPER LEVEL GAFNMGE - HVAP PLAN - AREA B scA 8 =1 _u - — - — - — - — - — --- - — - — - — - — - 7 — - 1011 aft"i NOT ALL KEY NOTES APPLY TO THIS SHEET GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. LOUVER IS LOCATED BELOW ESCALATORS • FLOOR ABOVE. PROVIDE CLEARLY IDENTIFIED SIMTCH FOR THE EMERGENCY PURGE VENTILA11ON IN A BREAK-MASS TYPE ENCLOSURE PROVIDING ON-ONLY CONTR- - -• s CLEARLY IDENTIFIED SMTCHES OF 13REAK GLASS TYPE PROVIDING OFF-ONLY CONTROL • ELECTRICALLY ENERGIZED EQUIPMENT/bEVICES VATHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCIiES IMMEDIATELY ADJACENT TO AND OUTSIDE • EACH REFRIGERANT MACHINERY ROOM EXT. PROVIDE APPROVED EMERGENCY SIGNS, C D LABLES IN ACCORDANCE VATH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND SYSTEMS. ICU UNPII '.' E Ain- P An t Vvnl MAY 2 3 2006 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART IHOWERTON NEW YORIC, NEW YORK STRUCTURAL ENGINEER MONROE & NE)XIELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIDER DESIGNS EDWARDS, COLORADO PROJECT NUI\MER. 20826.01 ISSUE REVISION DATE 001 DEF. SUB. 04-05.06 HVAC PLAN UPPER LEVEL GARAGE AREA B Cator, Ruma & Assoc. FlLENAME-P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P—HVNG1.DWG — M110.2B PLOT. 04/04/2006 0 1:03pm REV. 04/04/2006 CAD: christino XREF. HVNG1.dwg tb.dwg bg—gl.dwg a—fp—gl.dwg a—cr—g1.dwg xbgl—use.dwg kplan—ga.dwg kplan—gb.dwg kpion—gd.dwg S—GRID—MATCHUNEdwg tb—c.dwg kpIon—gc.dwg xbg—gl—fsl.dwg xbg—gl—fs2.dwg GI—GONDOLA.dwg S—GRID—GARAGE.dwg tb—smoke—defsubl.dwg xbg—gl—pumpeq.dwg elecgldwg 11 M 1 1 0,2B (� © 2003 42140 ARCHITECTURE, INC. KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET tU GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. Q LOUVER IS LOCATED BELOW ESCALATORS ON FLOOR ABOVE. Al O PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION IN A BREAK —GLASS TYPE ENCLOSURE PROVIDING ON —ONLY CONTROL. O PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF —ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. O PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND SYSTEMS. OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD ■ J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO NEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD PROG. 2 05.27.05 017 CD PROG. 2R 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDENDUM 14 07.29.05 HVAC PLAN UPPER LEVEL GARAGE AREA C Cator, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNGI.DWG — M110.2C PLOT: 08/08/2005 Q 9:19om REV: 08/08/2005 CAD: CRA XREF: HVNG1.dwg tb.dwg bg— gl.dwg a— fp— gl.dwg o— cr gl.dwg xbgl — usc.dwg kplan— gb.dwg kplon— gb.dwg kplon— gd.dwg S— GRID— MATCHLINE.dwg tb —a.dwg kplon— gc.dwg xbg— gl— fsl.dwg xbg— gl— fs2.dwg G1— GONDOLA.dwg S— GRID — GARAGE.dwg elecgl.dwg r. <� OGL S s o - . o ilAN 2 6 44NI 01 RAt M1 10.2C v -- (0 - -- ---- - 11 2003 42140 ARCHITECTURE. IM <D GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. (D LOUVER IS LOCATED BELOW ESCALATORS ON FLOOR ABOVE tz! PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE. CODE FOR THE REFRIGERA71ON UNITS AND SYSTA'As, OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ [ IOU AItC 1,111.1, I'll., ''I Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFERDESIGNS, EDWARDS, COLORADO Cator, Ruma & Assoc. FlLENAME:P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P—HVNG1.DWG — M110.2C PLOT 04/04/2006 01:04pm REV. 04/04/2006 CAD: christina XREF- HVNG1.dwg tb.dwg bg—gl.dwg a—fp—gl.dwg a—cr—gl.dwg xbgl—usc.dwg kplan—go.dwg kplan—gb.dwg kpion—gd.dwg S—GRID—MATCHLINE.dwg tb—a.dwg kplan—gc.dwg xbg—gl—fsl.dwg xbg—gl—fs2.dwgG1—GONDOLA.dwg S—GRID—GARAGEdwg tb—smoke—defsubl.dwg xbg—gl—pumpeq.dwg elecgl.dwg PROJECT NUMBER. 20826.01 ISSUE REVISION DATE 001 DEF. SUB. 04.05.06 1 n a /nn u � vr� in • �n n� �nr /30 UP KEY NOTE NOT ALL KEY NOTES APPLY TO THIS SHEET (D GREASE DUCT PITCHES TO GREASE TRAP IN MIDDLE OF RUN. Q LOUVER IS LOCATED BELOW ESCALATORS ON FLOOR ABOVE. PROVIDE CLEARLY IDENTIFIED SWITCH FOR THE EMERGENCY PURGE VENTILATION IN A BREAK -GLASS TYPE ENCLOSURE PROVIDING ON -ONLY CONTROL. ® PROVIDE CLEARLY IDENTIFIED SWITCHES OF BREAK GLASS TYPE PROVIDING OFF —ONLY CONTROL OF ELECTRICALLY ENERGIZED EQUIPMENT /DEVICES WITHIN THE REFRIGERANT MACHINERY ROOM. LOCATE SWITCHES IMMEDIATELY ADJACENT TO AND OUTSIDE OF EACH REFRIGERANT MACHINERY ROOM EXIT. PROVIDE APPROVED EMERGENCY SIGNS, CHARTS, AND LABLES IN ACCORDANCE WITH THE INTERNATIONAL FIRE CODE FOR THE REFRIGERATION UNITS AND YSTEMS. © 2003 4240 ARCHITECTURE, INC. ao o�w 4 oti "opUG 'on r' 27 L/ OWNER/DEVELOPER VAIL RESORTS TIUTTIu T nT)N fUXT'T" l.l1Li V .LiLI./1 lVl_"lN 1 COMPANY AVON, COLORADO ARCHITECT OF RECORD F , I ■ ARCHITECTURE Denver, Colorado MASTERPLA'NER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVII, ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE UPPER LEVEL GARAGE - HVAC PLAN - AREA D p SCALE: 1 /8 " =V -0" Cotor, Ruma & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- HVNG1.DWG - M110.2D PLOT: 04/27/2005 @ 7 :51om REV: 04/27/2005 CAD: morlone XREF: HVNG1.dwg tb.dwg bg- gl.dwg a- fp- gl.dwg o- cr- go.dwg xbgl- usc.dwg kplan- go.dwg kplon- gb.dwg kplon-gd.dwg S- GRID- MATCHLINE.dwg tb -a.dwg xbg- g1- laundry.dwg elecgl.dwg LINE AREA D s a = r� = m( LINE AREA A 0 A 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERNUT REV 03.24.05 008 PERiVIIT REV 04.07.05 HVAC PLAN UPPER LEVEL GARAGE AREA D M1 10.2D C, v V �� ` MATCH LINE AREA Q MATCH LINE AREA D T III 400 CF � T /F 7 FCU V �' `� 1-0 t 400 400 CFM OA YN 24 (N T DRE"N'S p 1 04- C FCU 0 - ICU CFM OA 2001 18/ 2 i I C i 01 CFM 0 0 1000 CF 2 � 30 DO 96/96 LOUVER fJ W� J 4k 80 1 %.q — - " p , 1�1 i OA 40 n, v i it V 90/36 E i 0 0 H 0 500 6FM 1 3800 CFM F6k D SKI SCRODI 36/24 MAKEUP 0 26X 0 1 � AIR DUCT DOWN C14 3900 24/20 GREAS EXHAUST CFM 12*0 DISH LU 400 ' OA EXHAUST 241 AKEUP-11 OA CUH ---------- ---- - --- --- K; A - FL 25 S 1 25 y � A �� � I , -- _- I I I l i l A Cu /FCU CFM OA 7 C) <1 00 a 1000 CFM V \ E) r LEVEL 1 - HVAC PLAN - AREA A SCALE: 1/8"1 '-0 Cator, Ruma & Assoc. FILENAME:P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P-HVN1.DWG M111.A PLOT: 04/25/2005 @3:46pm REV: 04/07/2005 CAD: morione XREF: HVN1.dwg tb.dwg bgl.dwg xbg-ucsnotes.dwg a-fp-Il.dwg A-CR-Ol.dwg L1-GONDOLA.dwg L1-NE.dwg L1-NW.dwg L1-SE.dwg L1-SW.dwg xbgl-usc.dwg Itgl.dwg S-GRID.dwg kplon-o.dwg kplan-b.dwg kplon-c.dwg kpion-d.dwg o-rcp-11.dwg L1-RAMP.dwg tb-c.dwg KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET GREASE DUCT PITCHED TO (2) GREASE TRAPS IN DUCT RUN. DISHWASHER EXHAUST. HOTEL LOBBY AND RESTAURANT HAVE GYP CEILINGS. SUPPLY AND RETURN GRIL ES WILL BE HIDDEN IN ARCHITECTURAL FEATURES IN THE CEILING. O SPA IS ALL GYP CEILING. PROVIDE ACCESS DOORS FOR REHEAT COILS. SUPPLY AND EXHAUST GRILLES WILL BE HIDDEN IN ARCHITECTURAL FEATURES. PROVIDE HYDRONIC RADIANT PANEL IN EACH TREATMENT ROOM ABOVE THE MASSAGE TABLE. A .A2 @ 2003 42140 ARCHITECTURE, INC. w L i OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD ■ ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC A MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERART REV 03.24.05 008 PERMIT REV 04.07.05 C D B go n0jerr N PROJECT KEYPLAN HVAC PLAN LEVEL 1 AREA A M1 11.A I I @ 2003 4240 ARCHITECTURE, INC. I I I �EGIS,7, Qj AIR INTAKE, B4x120 LOUVER - FOR BOILER COMBUSTION AIR 10 H OU 72/30 DUCT HAS ELBOW INTO BACK WALL OF INTAKE LN7- DOWN 01 rml to Pg*WlKjrl 0-- LOUVER V~ v 72x30 OA DUCT FOR BOILER ROOM '00 /1 001, — Q < V S T ,4' 8 MATCH LINE 'AREA C m A2 M* OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINT-ER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. D&N COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS , COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 0 PRICING PKG LOUVER V~ v 72x30 OA DUCT FOR BOILER ROOM '00 /1 001, — Q < V S T ,4' 8 MATCH LINE 'AREA C m A2 M* OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINT-ER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. D&N COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS , COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERINUT/B11) 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 C D FROJEcr N PROJECT KEYPLAN HVAC P LAN LEVEL 1 AREA B Cator, Rumo & Assoc. FILENAME:P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\DDS\MECH\P—HVN1.DWG — M111.13 PLOT: 04/25/2005 @3:47pm REV: 04/07/2005 CAD: marlone XREF: HVN1.dwg tb.dwg bgl.dwg xbg—ucsnotes.dwg o—fp—Il.dwg A—CR-01.dwg L1—GONDOLA.dwg L1—NE.dwg L1—NW.dwg L1—SE.dwg LI—SW.dwg xbgl—usc.dwg Itgl.dwg S—GRlD.dwgkp1on—c.dwg kplon—b.dwg kplan—c.dwq kplon—d.dwg a—rcp—Il.dwg L1—RAMP.dwg . tb—o.dwg m 1 • B KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET O GREASE DUCT PITCHED TO (2) GREASE TRAPS IN DUCT RUN. O DISHWASHER EXHAUST. 0 HOTEL LOBBY AND RESTAURANT HAVE GYP CEILINGS. SUPPLY AND RETURN GRILLES WILL BE HIDDEN IN ARCHITECTURAL FEATURES IN THE CEILING. ® SPA IS ALL GYP CEILING. PROVIDE ACCESS DOORS FOR REHEAT COILS. SUPPLY AND EXHAUST GRILLES W1LL BE HIDDEN IN ARCHITECTURAL FEATURES. PROVIDE HYDRONIC RADIANT PANEL IN EACH TREATMENT ROOM ABOVE THE MASSAGE TABLE. a 1.1 -- 1-- 71- G I � I. l i © 2003 42140 ARCHITECTURE, INC. 1 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ■ J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART J HOWERTON NEW YORK, NEW YORK STRUCTURAL FNIGIN'RER MON ROE & NEW ENGIINTIERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO IN DESIGN SLIFER DESIGNS EDWARDS,COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERI'v1IT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD PROD. 2 05.27.05 017 CD PROG. 2R 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDENDUM 14 07.29.05 D B A 'N r PROJECT KEYPLAN HVAC PLAN LEVEL 1 AREA C Cotor, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL UONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVNI.DWG — M111.0 PLOT DATE: 08/08/2005 @ 9:06om REV: 08/08/2005 CAD: hdy XREF: HVN1.dwg tb.dwg bgl.dwg xbg— ucsnotes.dwg a— fp— I1.dwg A— CR- 01.dwg L1— GONDOLA.dwg L1— NE.dwg L1— NW.dwg U— SE.dwg Ll— SW.dwg xbgl— usc.dwg Itgl.dwg kplan- -o.dwg kplon —b.dwg kplan —c.dwg kplon —d.dwg a— rcp— I1.dwg L1— RAMP.dwg tb —a.dwg xbgl— fs3.dwg xbgl— fs4.dwg xbgl— fs5.dwg L1 —NW perimeter.dwg S— GRID.dwg xbgl— A133.dwg xbgl— A132.dwg m 111 s C I ■ try i f f KEY NOTES: N OT • TO THIS SHEET jo- GREASE DUCT PITCHED TO (2) GREASETRAPS IN DUCT RUN. DISHWASHER at HOTEL LOBBY AND RESTAURANT HAVE GYP CEILINGS. SUPPLY AND RETURN GRILLES t IN ARCHITECTURAL FEATURES IN 1HE CE ILING. SPA IS ALL ' CEILING P M h. DOORS FOR REHEAT CO ILS. SUPPLY AND EXHAUST GRILI.ES WILL BE HIDDEN IN ARCHITECTURAL FEATURES. PROVIDE H)DRONIC RADIANT PANEL IN EACH TREATMENT ROOM ABOVE THE MAS 0 - - -•- - — u — 0 - -- - - - V — — OWNERIDEVELOPF.R VAIL RESORTS DEVELOPMENT COMP AVON, COLORADO ARCHITECT OF RECORD ARC!"ifElGiUtE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER .ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS ED4YJARDS, COLORADO PROJECT NUMBER 20826.01 4:1._. — — — - 72/30 ELBOW WALL O PLENUM LOUVER -------------- G � I I i I I f I i 0 u off a:�s a t 4a:. a c.,n xe„•�`a � sww„�.a ssp'a.b8 �. #�« "�' I SSUE RE V I SION DATE 001 DER SUB. 04.05.06 1 r _ } A EPA A P i LEVEL 1 AREA Ci Cator, Ruma & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P- HVNI.DWG - M111.0 PLOT DATE: 04/04/2006 0 1:05pm REV: 04/03/2006 CAD: christina XREF. HVN1.dwg tb.dwg bgl.dwg xbg- ucsnotes.dwg a- fp- il.dwg A- CR- 01.dwg L1- GONDOLA.dwg L1- NE.dwg Ll- NW.dwg Ll- SE.dwg Li- SW.dwg xbgl- usc.dwg itgl.dwg kpion -a.dwg kplon -b.dwg kpian -c.dwg kplan -d.dw a -rc -I1.dw Ll- RAMP.dw tb -a.dw xb 1- fs3.dw xb 1- fs4.dw xb 1- fs5.dw L1 -NW eri e - - 9 P g 9 9 g 9 9 9 9 9 p m ter dwg S GRID.dwg xbg1- A133.dwg xbgl- At32.dwg tb -smoke defsubl.dwg I I m 111 .0 C I I1 2 {f b i T E i IO fi u i'31 f�21 LE IN wJu I__ CONNF C I I T T Q 2003 4240 ARCHITECTURE, INC. 17 i f � as a� f i i � LEVEL 1 - HVAC PLAN - AREA D b SCALE: 1/8";; -0 B A PROJECT N PROJECT KEYPLAN HVAC PLAN LEVEL 1 AREA D KEY NOTES: NOT ALL KEY NOTES APPLY TO THIS SHEET Q GREASE DUCT PITCHED TO (2) GREASE TRAPS IN DUCT RUN. O DISHWASHER EXHAUST. 3O HOTEL LOBBY AND RESTAURANT HAVE GYP CEILINGS. SUPPLY AND RETURN GRILLES WILL BE HIDDEN IN ARCHITECTURAL FEATURES IN THE CEILING. V SPA IS ALL GYP CEILING. PROVIDE ACCESS DOORS FOR REHEAT COILS. SUPPLY AND EXHAUST GRILLES WILL BE HIDDEN IN ARCHITECTURAL FEATURES. PROVIDE HYDRONIC RADIANT PANEL IN EACH TREATMENT ROOM ABOVE THE MASSAGE TABLE. r OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT <E HART HOWERTON s NEW YORK, NEW YORK STRUCTURAL ENGINEER - -- -- - Fa MONROE NEWELL ENGINEERS, INC MEP ENGINEERS CATOR RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS 0.t EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE v 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 A' 007 PERIYIIT REV 03.24.05 0 008 PERMIT REV 04.07.05 INE AREA D Cator, Ruma & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \MECH \P— HVN1.DWG _ M111.D PLOT DATE: 04/25/2005 ®3:50pm REV: 04/07/2005 CAD: morione XREF: HVN1.dwg tb.dwg bgl.dwg xbg— ucsnotes.dwg o— fp— 11.dwg A— CR- 01.dwg Li— GONDOLA.dwg L1— NE.dwg L1— NW.dwg L1— SE.dwg L1— SW.dwg xbg1— usc.dwg Itg1.dwg S— GRID.dwg kplon —a.dwg kplon —b.dwg kplon —c.dwg kplon —d.dwg o— rcp— 11.dwg L1— RAMP.dwg tb —o.dwg mi 1 LD 1 �.:/ O a C:J I m 8 N A 1- 1 91 10�� ttt �a b b� HVAC PLAN - AREA D LEVEL 1 SCALE 1/8 NOT ALL KEY N07ES APPLY TO THIS SHEET GREASE DUCT PITCHED TO (2) GREASE TRAPS IN DUCT RUN. DISHWASHER EXHAUST. HOTEL LOBBY AND RESTAURANT HAVE GYP CEILINGS. SUPPLY AND RETURN GRILLES Y&L BE HIDDEN IN ARCHITECTURAL FEATURES IN THE CEILING. SPA IS ALL GYP CFJLJNG. PROVIDE ACCESS DOORS FOR REHEAT COIM SUPPLY AND EXHAUST GRILLES WILL BE HIDDEN IN ARCHITECTURAL FEATURES. PROVIDE HYDRONIC RADIANT PANEL IN EACH TREATMENT ROOM ABOVE THE MASSAGE TABLE. DOWN \ 0 F ; I VAL ftrAY 2 Cator, Ruma & Assoc. FILENAME VAIL LIONSHEAD CORE REDEVELOPMENT\CAD\D,DS\MECH\P—HVN1.DWG — M111.D PLOT DATE: 04/04/2006 01:06pm REV- 04/03/2006 CAD: christino XREF. HVN1.dwg tb.dwg bgl.dwg xbg—ucsnotes.dwg a—fp-11.dwg A—CR-01.dwg Ll—GONDOLA.dwg L1—NE L1—NW.dwg Ll—SE.dwg Ll—SW.dwg xbgl—use.dwg Itgl.dwg kp1an—a.dwgkp1an—b.dwg kplan—c.dwg kpion—d.dwg a—rcp—I1.dwgL1—RAMP.dwg tb—a.dwg xbgl—fs3.d xbgl—fs4.dwg xbgl—fs5.dwg L1—NW —GRID.dwg xbgl—Al33.dwg xbgl—Al32.dwg tb—smoke—defsubl.dwg 0 2003 42140 ARCHITECTURE, INC. OWNER/DEVELOPER NAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO .ARCHITECT OF RECORD ■ V [oi rTE"1171 IF F Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO C D B K� A] PROJECT N -1� PROJECT IMUN