HomeMy WebLinkAboutB05-0016 Plans (volume 3, pages 101-149)© 2003 42140 ARCHITECTURE, INC. r �Q 1 �(6 � l� i r G _ ___(B MATCH LINE AREA D - K.7 �� = =��m =��= =(: MATCH LINE AREA A L.2 L M.6 - N.2 -o GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12,#12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. 1 ` > LUMINAIRE LOCATED ABOVE DOOR. <� INSTALL UPPER EXIT SIGN AT 1 -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL �3) CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. < 4 INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. l6> CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. \\ \\IIIliII►j REG 81 � o : mo ( ON PL '�t�►►►tlt ml \\iN OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGIN MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE r z n _J S I i I I 1 I � � I 1. 22 23 24 4.4 25.1 LEVEL 3 - LIGHTING PLAN - AREA A SCALE: 1/8"=V-0" J O C 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D A % => PRo,Ec N PROJECT KEYPLAN LIGHTING PLAN LEVEL 3 AREA A E213.A MATCH LINE AREA C MATCH 05.21.04 LINE AREA B (. / D x) 2 5 6 a 7 8 i Q 9 i 531 SF _ I 11 01 I' ! E ! 0 - -- -r �.wrTi7 cb�VRC, INU. �p REGj c OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD [ oi l ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CVIL ENGINEER ALPINE ENGINEERING, INC, VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 0 C) 0 N 0 N W s n N 0 0 0 N 0 a M N W 0 U W 0 0 i z w a 0 0 0 V O Q W N Z O J Q 1 r\ M N M O O N M O O vc:NC:MAL IN I C5: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION, CONSULT ARCHITECT/ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2'C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. \% LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6' MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8` FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. Q INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. / 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D PRO1Ecr N PROJECT KEYPLAN LIGHTING PLAN LEVEL 3 AREA B 2 i � � B8 I HOTEL 996 SF L—=J HOTEL 3N 533 SF 0 a _ HOTEL 500 SF HOTEL 3L 538 SF a — HOTEL 3K 657 SF U . MR HOT T 531 SF MATCH LINE AREA C MATCH LINE AREA B �11 HOTEL 5 � 7 R HOTEL HOTEL 3 3 * 4 — — — — — — — — — — — -- — — — — — - - - -_ — — — — — — — - --------------- 27 D� 27 IF 1 1 lll� 111 �Nl L - ELEV 10 --SLF2 CIRCUI TO S DP _j <x 7 _SLF2_ J L - - - - - - - -1 L - - - -1 L J L LF2 I 1� k LWPJ_ Z�_ FE L 1=3 --------------- --------------- -------------- --------------- --------- - - - it ----- - Xl 23 23 DW DW #25 I 25 OW DW 4 5 25 OW I I DW V27 I 27 DW I CIRC� 27 -- - - - - -- --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - *ESL 1 DW DW J2 DW #25 25 DW DW 27 2 s, DW I I ! J lt3 m DP FF 524 E: A T (C) r DW 0 OIL J 0 Xl 4 DW 77 1_ I 23 a . - ( J F _. -In .01-7 _0 231: CIRCUIT TO DW GE.NERAL_N0_TES,- C Q (D 1 REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. 23 3 B L J CONSULT ARCHITECT/ENGINEER FOR CLARIFICATIONS. sV # R l NC DW 48 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED ATEAS UNLESS OTHERWISE NOTED. L 141 3. WHERE EXPOSED CONDUIT IS ALLOWED, PA H EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. m. rsd UJI 0 DW =-I 21 21 7 DW - ------ 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS, 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. -Z LIGHTING PLAN NOTES: ! � � f j 1 I . REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. L_ _J 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH-IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 1 �� 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND/OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 10 I I I � I � I �If ! - = i a HOTEL 3 17 746 SF HOT TEL HOTEL HOTEL V HOTEL 3 3T 3 3 1 SF 5# isf- SF 60tw_ LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE L RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. CONDO 3N 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE*, COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. LEVEL 3 - LIGHTING PLAN - AREA C SCALE: 1/8"=V-0" ALL BRANCH CIRCUITING IS 2#12,#12G-1/2"C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. <� LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7'-6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4* FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL <� CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. <✓ CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO 'W-SERIES' DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. @ 2003 42140 ARCHITECTURE, INC. % cr N /111111 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT AVON,COILORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HARTIHOWERTON NEW YOM NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C." D B A mojEcr N PROJECT KEYPLAN K:1 LIGHTING PLAN LEVEL 3 AREA C E213.0 17 19 20 21 22 23 24 5. 26 I � I I I I I { I E { I I l ' I { I I I I I I 3 ( I I I ! ! I E i I � I I i { { r I I I I 0 ncg xozm���smwqj 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4, DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FIFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. �J LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 42140 ARCHITECTURE, INC. \ Oki j 11 i 11111 1 10 11 RED / �� �• •! BUG �� �� Ovt �p� FiS' z U' 81 = { C OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD *ARCHIT Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK E.2 - F.1 STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATO1 RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 0 r v J Y E a v c 0 J 2 -- F.9 - J.2 - K.1 MATCH LINE AREA D �— K. 7 ........ m m .■..w� = . ■s m m(: MATCH LINE AREA A ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 B A mo,� N PROJECT KEYPLAN LEVEL 3 - LIGHTING PLAN - AREA D SCALE: 1 8 " =1' -0" (c) 2003 42140 ARCHITECTURE. IN& I J �tp 1 �(6 �5 G 1 � __( MATCH LINE AREA D MATCH LINE AREA A L.2 L.9 M.6 - N.2 GENERAL NOTE 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED $O THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1 /2 "C. UNLESS OTHERWISE NOTED. DET AIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. G � LUMINAIRE LOCATED ABOVE DOOR. � INSTALL UPPER EXIT SIGN AT 7 -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. <� INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. 5� FUTURE FINISH AREA. <6> CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO 'W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. \\, �,WWiWlilttllrlrJ // REG �. �� _ ti. ��C° •'• .....• �� OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD PA . 1 04 t l J ARCx Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE s O Of W 0 O N O N O cr a t` O N In O O N \ O N O 0 O J a f I 22 23 24 4.4 25.1 LEVEL 4 - LIGHTING PLAN - AREA A a SCALE: 1 8 " =1' -0" O '\__0 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D PROJEcr N PROJECT KEYPLAN LIGHTING PLAN LEVEL 4 AREA A E214.A 1 1.1 i I I MATCH LINE AREA J �■ MATCH LINE AREA _ I 0 W a 0 N 0 D W E a 0 C 0 0 ii o 0 A"% !— \ t !— P'1 A I L I / \'T!— 0% LUNbUL I AKUiI I tG I /tNUINttK t VK GLAKIt K;A I IUNb. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. 2 5 6 (7J (8) (9) LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE% COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2#12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. m r" _r" A 1 1 ► I r% T r- r1 ' " 1 1 1 ^ e% 1 1 r— r— "T' _ �✓ LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8' FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. � CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. <� CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES* DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. E \ f - t r n 2003 42140 ARCHITECTURE. IN& \\it\\1 lI I I j,,,, /;� REGj /', s ' ••H �. 181. '.. : • e tc, - ONAL ,,, / /!I N f111 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD � i * AIC.1TECTURE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 s ' 05.21.04 004 PRICING PKG 06.21.04 005 I 2 -LANE LAP i I PERMIT /BID I POOL E i i A"% !— \ t !— P'1 A I L I / \'T!— 0% LUNbUL I AKUiI I tG I /tNUINttK t VK GLAKIt K;A I IUNb. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. 2 5 6 (7J (8) (9) LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE% COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2#12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. m r" _r" A 1 1 ► I r% T r- r1 ' " 1 1 1 ^ e% 1 1 r— r— "T' _ �✓ LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8' FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. � CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. <� CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES* DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. E \ f - t r n 2003 42140 ARCHITECTURE. IN& \\it\\1 lI I I j,,,, /;� REGj /', s ' ••H �. 181. '.. : • e tc, - ONAL ,,, / /!I N f111 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD � i * AIC.1TECTURE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 i i LIGHTING PLAN LEVEL 4 AR EA B C D D PRo N PROJECT KEYPLAN 8 9 10 11 12 13 I C � i I (D___ __ - - - - a -- - - B.8 ti GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LI GHTING PLAN NOTES: I. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2/12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. LUMINAIRE LOCATED ABOVE DOOR. < 2 INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. ''� CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE, REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. < 5 FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. Q 2003 42140 ARCHITECTURE, IN& U Cc: z000.= ��ittltlil{t \ \ \\ OWNER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD � 1 �J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEP.RING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE MATCH LINE AREA C -- = - MATCH LINE AREA B O 0 0 N O_ C N O w E C, 0 N O O N O N O O J a 0 O LEVEL 4 - LIGHTING PLAN - AREA C a SCALE: 1/8 " =1' -0" 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 j/ /' / B A PROJECT KEYPLAN � T - LIGHTING PLAN LEVEL 4 AREA C E214.0 I ( a7 2003 42140 ARCHITECTURE, IN& I i \00k titlfllllJt //! P Qp REG, -� 1 81 1 ac 6 2000 J//J JJ11111111 11 \ \\\ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J *A1r..1T Denver, Colorado 17 19 20 21 22 23 24 15.E 26 } i I t I ! I - -fl E.2 -- F_ 1 __ F_9 GENERAL NO TES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3, WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: I. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2/12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. <2> CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. 'S FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SI TFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 0 N U) O O N O N 0 W n C3 0 N N O O v N O H O J d - G.9 -- __(D K.1 MATCH LINE AREA D - ----e �� = m �� = m �� m m( MATCH LINE AREA A L_2 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 B A P ROJECT ' LEVEL 4 - LIGHTING PLAN - AREA D (YI SCALE: 1/8"=V-0" LIGHTING PLAN LEVEL 4 AREA D E214.D I I © 2003 42140 ARCHITECTURE, IN& I �s �5 r i G� ___8 MATCH LINE AREA D — — K.7 �� = m �� = 1. ■� ■. =( MATCH LINE AREA A L.2 0 M.6 N.2 0 GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4, DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FiRE SEAL ALL FiRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WiLL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4, IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 ° C. UNLESS OTHERWISE NOTED. DETAIL NOTES THiS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. <:j> LUMINAIRE LOCATED ABOVE DOOR. < 2 INSTALL UPPER EXIT SIGN AT 1 -6 MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8 FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. <, j CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. <� INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FiNiSH AREA. < 6 > CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO 'W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. Q O REGj CC = .il', IGt Ott / /1Ui l l i II\t OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARC}iITECTURE Denver, Colorado MASTER PLAT INER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE r O w N O O N O N O w O. C3 O O N O O O a E f i 1. 22 23 24 4.4 5.1 0 LEVEL 5 - LIGHTING PLAN - AREA A b SCALE: 1/8"=V-0' -o 0 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D B mojEcr N PROJECT KEYPLAN LIGHTING PLAN LEVEL 5 AREA A E215.A O w w K, 0 SZ uj 0 N O w E a In 0 (V c) O 0 N O 0 0 a I MATCH LINE AREA MATCH LINE AREA 0 --- O O i A'% r- & 1 r- r1 A I & 1 10% "w" r^ 0% i UJ(VJVLI AKU11It /tNUlNttK YUK GLAKINUAUUNS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. 1 1 1T1L 1/"1 MI A \ I L 1/1 r Lnrw r VIN LA^k. I mvVIN I 111 LVLn IIVi`1.7 Vr UL VILLJ MI '4U LVMI[NmIRLJ. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 ° C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. G�> LUMINAIRE LOCATED ABOVE DOOR. <-> INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. < 4 INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. G6> CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES' DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. I I i i r n 2003 42140 ARCHITECTURE, IN& \ ktlliiill/// /�J `� REra�s% � p�.o • •FJ;.. ullnlr» OWNER/DEVEI.OPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS,COLORADO PROJECT" NUMBER: 20826.01 ISSUE REVISION DATE 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 LICHTING PLAN LEVEL 5 AREA B I C D A PRO)ECr N PROJECT KEYPUN 1 1.1 2 5 (6 ) 7 8 (9) 14 11 12 13 I � I k I � I I I r I i i i i a B_8 �J G ENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3, WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. 00 NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. <> LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. < � CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. !�4 > INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. 1 �> CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. CcZ 2003 42140 ARCHITECTURE. IN& Ilrtl .U; - �U c OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ii ARCHIT'ECT'URE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL. ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DEN WER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE MATCH LINE AREA C - - -- - - ---- MATCH LINE AREA B O 0 N O O W E n v 0 N t! J O O N O O 0 O J a a_ LEVEL 5 - LIGHTING PLAN - AREA C p SCALE: 1 8 " =1' -0" 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 i% B A N PROJECT KEYPLAN LIGHTING PLAN LEVEL 5 AREA C E215.0 O cr W 0 N 0 0 W >r a 0 N C) 0 0 0 C> 0 0 J CL 17 19 20 21 22 23 24 5. 26 LEVEL 5 - LIGHTING PLAN - AREA D SCALE: 1/8"=V-0" 0 — E.2 F.1 F9 — G.9 — J.4 — K.1 MATCH LINE AREA D - ---e �� m = �� = m �� m m( MATCH LINE AREA A L.2 GE NERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3, WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: I. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE, COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. 9 LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. �3 CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. < ' INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 42140 ARCHITECTURE, IN& I PC) RE G U _ '. JANj TGG6 = Al- - Lt1 '�J�1t111it1lt� OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD �j ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 D A PRo,WT N PROJECT KEYPLAN LIGHTING PLAN LEVEL 5 AREA D E215.D © 2003 42140 ARCHITECTURE, IN& J 1 1 J �(6 � �F �F 1 G1 O Qf ui 0 0 N 6 N O W (r it O C) O O N O N O H O J a I i � I I 1. 22 23 24 4.4 25.1 - - - K.1 L.2 - L.9 - N.2 C o o MATCH LINE AREA D �� m m �� m = �� = =(: MATCH LINE AREA A GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3, WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRi, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON °FFE LUMINAIRE SCHEDULE', COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER, ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 ° C. UNLESS OTHERWISE NOTED. DETAIL NO TES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. �-' LUMINAIRE LOCATED ABOVE DOOR. <T> INSTALL UPPER EXIT SIGN AT 7-6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8° FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. l4� j INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. �6 CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. ,` ���1111ititrrrtJ J " Pi p REGI Q 781 C s lltiil C D B PROJacr N PROJECT KEYPLAN LEVEL 6 - LIGHTING PLAN - AREA A b SCALE: 1/8"=1 -0 LIGHTING PLAN LEVEL 6 AREA A E216.A 0 10 b O b C'4 U.1 E rgi 0 cv 0 0 N \ O N O 0 0 a \ 11 MATCH LINE AREA C MATCH LINE AREA B i Cam' o _ I � i 2 5 (6 } 7 i 0 0 (I D6 GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT/ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON 'FFE LUMINAIRE SCHEDULE% COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12,##12G- 1/2'C. UNLESS OTHERWISE NOTED. P'1 r- - r A I I h 1 e% T r- ^ T i 11^ ^ i I r- r'' _ <2> LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6' MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8' FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4' FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. <� INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO 'W SERIES' DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. i i s I .i i i i © 2003 42140 ARCHITECTURE, INIL .,��•<`�SS,...... R; ON ION RL OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERT UT /BID 02.15.05 LIGHTING PLAN LEVEL 6 AREA B C D !A m0 N PROJECT KEYPLAN 8 12 13 i E i o (D_ - - - - - B_$ o GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON ° FFE LUMINAIRE SCHEDULE', COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. l�,1,> LUMINAIRE LOCATED ABOVE DOOR. <✓ INSTALL UPPER EXIT SIGN AT 7' -6' MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. 3 CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED NTH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. <, CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W-SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. Q 2003 42 140 ARCHITECTURE, INIL iiiitri! /j/ REG�s�; 7 w = Vic, Q . 0NA /, 11111111 0 � OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE MATCH LINE AREA C MATCH LINE AREA B 0 N 0 0 N O_ N O W a M O fv ,C1 O O N O N O O J a LEVEL 6 - LIGHTING PLAN - AREA C �l SCALE: 1/8"=1'-0" 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 i B A mqwr PR OJECT "' LIGHTING PLAN LEVEL 6 AREA C E216.0 17 19 20 21 22 23 24 5. 26 i i f i 0 - - C.9 GEN ERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2#12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. < � LUMINAIRE LOCATED ABOVE DOOR. � INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. 5� FUTURE FINISH AREA. < � CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 4240 ARCHITECTURE, INS RE �jsT''% 197 ' C o AN 2 2oos .'` `\ ��l \ \ \ � OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado E.2 - ___ -__ F 1 MASTERPLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGDMERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIDER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE O Of W CD 0 0 N 0 0 W E CL N O N a 0 0 0 N O 0 O J CL LEVEL 6 - LIGHTING PLAN - AREA D p SCALE: 1/8"= —0 -- - J.4 - - - K.7 MATCH LINE AREA D MATCH LINE AREA A 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C B c I A PROJEcr i PROJ LIGHTING PLAN LEVEL 6 AREA D E216.D .r- r r f/ �{6 E \ E l l f I I I I I I 46�> LEVEL 1. 22 23 SCALE: 1 8 =1 7, r� G� GENERAL N OTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PL NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7, FOR ALL LUMINAIRES ON ° FFE LUMINAIRE SCHEDULE COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 ° C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHE NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. :> LUMINAIRE LOCATED ABOVE DOOR. 2� INSTALL UPPER EXIT SIGN AT 7' -6° MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4' FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL �3J CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. G � INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. FUTURE FINISH AREA. 6� CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 4240 ARCHITECTURE, IN& RE%N% ; E _ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD E � ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE r=- l � wm__9Kejm=N�_ - K.1 K.7 L.2 L.9 M.6 N.2 c ___E) _\ —<D -C MATCH LINE AREA D �� = = �� m m �Mll m ml(: MATCH LINE AREA A 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PICG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 :r. r- \ PROJECT KEyp �r Cator, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTG7.DWG — E217.A PLOT: 02/10/2005 @ 2:02pm REV: 02/10/2005 CAD: iro XREF: Itg7.dwg tb.dwg xbg— ucsnotes.dwg L5— C— Z— ROOF.dwg bg7.dwg o— fp- 17.dwg L7— C —L.dwg L7— C —M.dwg L7— C —W.dwg A— CR- 07.dwg L7— C —J.dwg clg7.dwg S— GRID.dwg kplon —o.dwg kplan —b.dwg kplon—c.dwg kplon — d.dwg A— FP— RF.dwg A— CR— RF.dwg xltg7— units— Ida. dwg A— MACH— LINE— 6 -7.dwg C D B ,,, A:rl,,:; MATCH LINE ARE, IN �� m _= d1111111111111111 MATCH LINE ARE, O� 0 -- 0 © 2003 42140 ARCHITECTURE, INIL c siON Al ir J�fr ilul ttt��� OWNER/DEVELOPER 0 0 ( D o // L� LIGHTING PLAN N OTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEIUNG PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR RENEW PRIOR TO ROUGH —IN. 3, ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTG7.DWG — E217.8 PLOT: 02/10/2005 @ 2:01pm REV: 02/10/2005 CAD: iro XREF: Itg7.dwg tb.dwg xbg— ucsnotes.dwg L5— C— Z— ROOF.dwg bg7.dwg o— fp- 17.dwg L7— C —L.dwg L7— C —M.dwg L7— C —W.dwg A— CR- 07.dwg L7— C —J.dwg clg7.dwg S— GRID.dwg kplon —o.dwg kplon — b.dwg kplon — c.dwg kplon A — FP RF.dwg A — CR RF.dwg xltg7 units Ido.dwg A — MACH — LINE 6 - 7.dwg 1 �{2 l �G �G 1 i VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART ( HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL EAIGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIl.ENGII3EER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D i/ , v np N PROJECT KEYPLAN LIGHTING PLAN LEVEL 7 AREA B E217.B O 1.1 O 5 6 7 8 9 I i � I CONTINUED ON AREA "C" i 8 9 10 11 12 13 `✓ o 0 o I t � i I � � E i ( t I ( � ( i i 0 B_8 o_ o -. GENE RAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. 00 NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON ° FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 ° C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6 MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8 FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. n FUTURE FINISH AREA. - CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 4240 ARCHITECTURE, IN1Z � \ P \\ � %„REiGj,` T 1 81 ' cc = ' 4j / t /l1tlliiVll��� OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT' OF RECORD ARCkITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 o_ MATCH LINE AREA C MATCH LINE AREA B CONTINUED ON AREA ° B ° LEVEL 7 - LIGHTING PLAN - AREA G p SCALE: 1/8"=V-0" ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 %�%%f D B C A ] PROJECT KEYPLAN LIGHTING PLAN LEVEL 7 AREA C Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTG7.DWG — E217.0 PLOT: 02/10/2005 ®2:00pm REV: 02/10/2005 CAD: iro XREF: Itg7.dwg tb.dwg xbg— ucsnotes.dwg L5— C— Z— ROOF.dwg bg7.dwg a— fp- 17.dwg L7— C —L.dwg L7— C —M.dwg L7— C —W.dwg A— CR- 07.dwg L7— C —J.dwg cig7.dwg S— GRID.dwg kplon —o.dwg kplon —b.dwg kplon —c.dwg kplan —d.dwg A— FP— RF.dwg A— CR— RF.dwg xitg7— units— Ida.dwg A— MACH — LINE- 6 -7.dwg E 2 17. C 17 19 20 21 22 23 24 5. 26 I I ! i � 3 s I I I i 1 ( I I ( I I I I I i { i I ( I I ( I I I ( i I ► ( L GENER NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: I. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. � LUMINAIRE LOCATED ABOVE DOOR. < INSTALL UPPER EXIT SIGN AT 7-6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. 3,. CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. < ✓ FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS, REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. Q 2003 42140 ARCHITECTURE, IN& ��'Ppfl BEG /ST %% t� (� 1z UJF ON N\- lf1111110 \ \\ OWNTER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD FA ARCHITECTURE Denver, Colorado LEVEL 7 - LIGHTING PLAN - AREA Q b SCALE: 1/8"=V-0" MASTER PLANNER DESIGN ARCHITECT HART { HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 -o -- F.9 ISSUE REVISION DATE - - -- J.2 - J.4 - K.1 - K.7 - L.2 MATCH LINE AREA D ® = ®� m m awe m( MATCH LINE AREA A Cator, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTG7.DWG — E217.D PLOT: 02/10/2005 0 1:59pm REV: 02/10/2005 CAD: ira XREF: Itg7.dwg tb.dwg xbg— ucsnotes.dwg L5— C— Z— ROOF.dwg bg7.dwg o— fp- 17.dwg L7— C —L.dwg L7— C —M.dwg L7— C —W.dwg A— CR- 07.dwg L7— C —J.dwg cig7.dwg S— GRID.dwg kplan—o.dwg kplan—b.dwg kplan —c.dwg kplan —d.dwg A— FP— RF.dwg A— CR— RF.dwg xltg7— units— ido.dwg A —MACH— LINE- 6 -7.dwg 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C B A Mo)� N PROJECT KEYPLAN LIGHTING PLAN LEVEL 7 AREA D E217.D � � V s' i G� I I I I i i 1. 22 23 24 4. 5.1 ROOF - LIGHTING PLAN - AREA A �vJ SCALE: 1/8"=V-0" Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- LTGR.DWG - E218.A PLOT: 02/10/2005 ®1:58pm REV: 02/10/2005 CAD: iro XREF: Itgr.dwg tb.dwg bgr.dwg xbgl - usc.dwg o- fp- rf.dwg S- GRID.dwg kplon -o.dwg kplon - b.dwg kplon -c.dwg kplon - d.dwg A- CR- RF.dwg A- MACH - LINE- 6 -7.dwg - K.1 - K.7 L.2 ____e -- o _o n MATCH LINE AREA D �� m = �t m m to a m(: MATCH LINE AREA A GE NERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEIUNG TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET. NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. LUMINAIRE LOCATED ABOVE DOOR. INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. <�3�,, CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. < 4 INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. 5� FUTURE FINISH AREA. <�> CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W-- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. © 2003 42140 ARCHITECTURE, IN%, cr _ Lit �'- Asi* ttttlii\ C D PRO , �r LIGHTING PLAN ROOF AREA A I I © 2003 42140 ARCHITECTURE. INQ, I I MATCH LINE ARE) MATCH LINE AREi Q __ - o _ A © REGI = 1971 cc- �� /J /t!tlllil\i \1 OWNER/DEVELOPER 0 + S �G �G 1 l LIGHTING LAN NOTES: G : C7 S 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5. LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1 /2'C. UNLESS OTHERWISE NOTED. VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12,04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 C D PRo,Ecr N PROJECT KEYPUN LIGHTING PLAN ROOF AR EA B Cotor, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTGR.DWG — E218.B PLOT: 02/10/2005 @ 1:58pm REV: 02/10/2005 CAD: ira XREF: Itgr,dwg tb.dwg bgr,dwg xbgl— usc.dwg o— fp— rf.dwg S— GRID.dwg kplon —o.dwg kpion —b.dwg kplan —c.dwg kplon —d.dwg A— CR— RF.dwg A— MACH — LINE- 6 -7.dwg i i 1 1.1 2 5 6 7 8 9 10 11 12 13 a a I l � I 1 a ---- 6.8 O o-- 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT /ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOT 1. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH -IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT -OF -HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. U LUMINAIRE LOCATED ABOVE DOOR. \°/ INSTALL UPPER EXIT SIGN AT 7 -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4' FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. < 3 CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. \'/ INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. �-' FUTURE FINISH AREA. f�6 > CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W- SERIES" DRAWINGS - LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR, Q 2003 42140 ARCHITECTURE, INIL 00 iREjGs / /J/ i Z 0WNER(DILI MWPER VAIL RESORT'S DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 MATCH LINE AREA C m m • m I �-- — - — — MATCH LINE AREA B � ROOF - LIGHTING PLAN - AREA C p SCALE: 1 8 " =1' -0" ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 B A N PROJECT KEYPLAN LIGHTING PLAN ROOF AREA C Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- LTGR.DWG - E218.0 PLOT: 02/10/2005 @ 1:58pm REV: 02/10/2005 CAD: iro XREF: Itgr.dwg tb.dwg bgr.dwg xbgl- usc.dwg o- fp- rf.dwg S- GRID.dwg kpion -o.dwg kplan -b.dwg kpion -c.dwg kpion -d.dwg A- CR- RF.dwg A- MACH - LINE -6- 7.dwg E218-C 17 19 20 21 22 23 24 5. 26 I f I I k I I — C.9 GENERAL NOTES: 1. REVIEW ALL CONTRACT DOCUMENTS FOR SUPPLEMENTAL DESIGN INFORMATION. CONSULT ARCHITECT/ENGINEER FOR CLARIFICATIONS. 2. INSTALL RACEWAY SYSTEM CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. 3. WHERE EXPOSED CONDUIT IS ALLOWED, PAINT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA UNLESS OTHERWISE NOTED. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 6. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: I. REFER TO ARCHITECTURAL AND INTERIOR DESIGNER ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. WHERE LUMINAIRE LOCATIONS NEED TO BE ADJUSTED, PROVIDE DOCUMENTATION OF PROPOSED REVISION TO ARCHITECT /ENGINEER FOR REVIEW PRIOR TO ROUGH —IN. 3. ALL LAMPS WILL BE 2500K COLOR TEMP, WITH MINIMUM 82 CRI, UNLESS OTHERWISE NOTED. 4. IN FRONT —OF —HOUSE AREAS, SWITCHES AND CONTROL PANELS SHALL BE CONCEALED AND /OR LOCATED BY ARCHITECT OR INTERIOR DESIGNER. 5, LUMINAIRES IN ELEVATOR PIT OR MACHINE ROOM, CONNECTED TO THE SERVICE RECEPTACLE IN THE SAME PIT OR ROOM, SHALL BE CIRCUITED SO THAT RECEPTACLES ARE NOT SWITCHED. 6. COORDINATE ALL CEILING TYPES AND LUMINAIRE TRIMS WITH ARCHITECT AND INTERIOR DESIGNER. 7. FOR ALL LUMINAIRES ON "FFE LUMINAIRE SCHEDULE ", COORDINATE WEIGHT OF LUMINAIRE AND MOUNTING REQUIREMENTS WITH INTERIOR DESIGNER. ALL BRANCH CIRCUITING IS 2 #12, #12G- 1/2 "C. UNLESS OTHERWISE NOTED. DETA NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED THIS SHEET. \% LUMINAIRE LOCATED ABOVE DOOR. <� INSTALL UPPER EXIT SIGN AT 7' -6" MINIMUM TO BOTTOM OF LUMINAIRE HOUSING. LOWER EXIT IS REMOTE CIRCUITED TO UPPER EXIT, VIA AC POWER. INSTALL LOWER LUMINAIRE AT MAXIMUM 8" FROM FLOOR TO BOTTOM OF HOUSING, AND MAXIMUM 4" FROM DOOR TO SIDE OF HOUSING IF LOCATED ADJACENT TO EXIT STAIRWELL. ,> CIRCUIT NIGHT LIGHT (NL) LUMINAIRE AHEAD OF SWITCH LEGS AND CONTACTORS. �4} INDICATES LIGHTING CONTROL ZONE. REFER TO CONTROL SCHEDULE ON DRAWING E002.3. EACH HOMERUN TO DIMMING PANEL SHALL BE INSTALLED WITH A DEDICATED NEUTRAL CONDUCTOR. C4 FUTURE FINISH AREA. CIRCUITS FOR POOL /TUB WET NICHE LIGHTS. REFER TO "W— SERIES" DRAWINGS — LUMINAIRES INSTALLED AND CIRCUITED BY WATER FEATURE CONTRACTOR. Q 2003 42140 ARCHITECTURE, IN& BE ' pct d _ 6 2u0 ' ��••'' . C? � A- 11111111%\ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado E2 F.1 f= . 9 MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE ROOF - LIGHTING PLAN - AREA D a SCALE: 1/8 " =1' -0" — G.9 J.2 _ ._.. J_4 - K.1 — K.7 L2 MATCH LINE AREA D MATCH LINE AREA A 002 DD FROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 C $ A Mo,WT N PROJECT KEYPLAN LIGHTING PLAN ROOF AREA D Cator, Rumo & Assoc. FILENAME:P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— LTGR.DWG — E218.D PLOT: 02/10/2005 ®1:57pm REV: 02/10/2005 CAD: iro XREF: Itgr.dwg tb.dwg bgr.dwg xbgl— usc.dwg o— fp— rf.dwg S— GRID.dwg kplan —a.dwg kplon — b.dwg kplon —c.dwg kplon —d.dwg A— CR— RF.dwg A- -MACH— LINE- 6 -7.dwg 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210-52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL Bi SEPARATED LATERALLY BY NO LESS THAN 12' IN SE PARATE # CAVITIES SEPARATED BY A V ER11CAL STU EACH ELECTRICAL BOX SHALL BE 10OX SEALED WITH A FIRE RATED (ASTME 814, UL BA CKING 1479) PUTTY ! HAVING A MINIMUM STC RATING O BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E-500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH—IN FOR LOW V OLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK LOCK-OFF - it 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL • !! UNIT LI AN D LOCATIONS O 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECE 7. REFER T O REFERENCE ELECTRICAL PLANS F OR LOCATION OF ! i♦ UNIT PANE 8. WRING DEVICE f UNTING HEIGHTS SHALL BE TYPICAL AS FOLLO RECEPTA TO CENTER !` • T O CENTER •i T WERE ADJACENT TO BED C. ` • TO D RECEPTACLE AND TH MOUNTING H E I GHTS I ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND/OR THERMOSTATS SHALL M a► F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS, � i t 1. THESE NOTES SHALL APPLY TO HOTEL ROOMS 224, 226, AND 228 FOR ADA ACCE SSIBILITY , AND SHALL BE USED IN CONJUNCTION OTHER GENERAL AND DETAIL N07ES • ON DR AWING. 2. REFER TO ARCHITECTURAL PLAN A054 FOR ARCHITECTURAL CHANGES IN ACCESSIBLE UNITS. LOCATION FOR ALL WRING DEVICES SHOWN SHALL BE ADJUSTED TO ACC OMMODA TE 3. M OUN71NG HEIGHTS FOR DEVICES SHALL BE MODIFIED TO MEET CU ADA STANDARDS AND GUIDELINES. 4. PROVIDE UNSWITCHED DUPLEX RECEPTACLE AT UNIT TELEPHONES FOR TTY PHONE. REFER TO T SERIES DRAWINGS FOR LOCATION OF TELEPHONES. CIRCUIT TO ADJACENT UNSWITCHED RECEPTACLE CIRCUIT. PHONE SHALL BE PROVIDED WITH VISUAL RING ANN OUNCEM ENT (• 5. PROVIDE 120V CIRCUIT FROM NEAREST UNSWITCHED RECEPTACLE FOR DOORBELL DOORBELL TO BE SPECIFIED BY INTERIOR DESIGNER. PROVIDE AND INSTALL DESK TOP RECOVER AND STROBE TO ANNUNCIATE DOOR BELL — ONE FOR SLEEPING ROOM AND ONE •- BATHROOM EQUIPM ! BY PHONE • OR APP ROVED EQ .A t � • MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC:. VAIL, COLORADO INTERIOR DESIGN SLIEER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.41 ISSUE REVISION DATE OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OE RECORD ■ J Denver, Colorado 002 N N OT N # O N 04.1.2.04 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN DD FROG 2 CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR 004 MAT AND PROGRAMMABLE THERMOSTAT JNTG5110. REFER TO ELECTRIC FLOOR MAT 06.21.04 DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. CD FROG SET PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MULn—SERmCE FLOOR 006 BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOiCE/DATA OUTLETS. FLUSH 02,15.05 COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. PERMIT REV PROVIDE JUNCTION BOX FOR SINGLE POINT CONNEC11ON OF GAS FIREPLACE 008 (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNEC11ON REQUIREMENTS WITH 04.07.05 FIREPLA i• TO ROUG ADDENDUM 4 PROVIDE 24OV, 3OA/,3P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. 012 VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO 05.27.05 `- <§> PROVIDE MEDIA CENTER AT +8'-6* A.F.F. TO BOTTOM AND (2) 2w C. TO TR ROOM 019 DESIGNATED BY ZONES ON *T-100' SERIES DRAWINGS THIS FLOOR. 07.07.05 OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION AD 14 WITH INTERIORS DRAWINGS PRIOR TO ROUGH—IN. <�> PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO RAT SCREEN T.V. 12 -15 -05 C ONFIRM • i i' TO -! <�> RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO .• PROVIDE JUNCTION BOX FOR 120V CONNEC11ON TO THERMOSTAT. PROVIDE C ONTROL • i TO ASSOC HVAC UNIT REFER TO MEC HANICAL F OR CONTROL WRING CONNECTIO PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY i EXHAUST HOOD SUPPLIER PRIOR TO `• M OUNTING PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48* A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH—IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION ! UNIT POW O NLY. INSTALL ELECTRONIC TimER SWITCH IN—LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. 11ME RANGE SHALL BE 0-180 MINUTES FOR LIVING ROOM FIREPLACE AND 0-60 MINUTES FOR BEDROOM FIREPLACES. VERIFY M OUNTING I INT DRAWINGS PRIOR TO -• PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCA11ON WITH INTERIORS DRAWINGS PRIOR TO ROUGH—IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY .j PROVIDE N DOOR F OR CLOSET LIGHTING #••- IS OPEN AND * OFr WHEN ! #•• IS CL OSED . CE ! ai LUMINAIRE FURNISH WITH FF&E PA CKAGE , i1 BY ELECTRICAL C ONTRACTOR . PROVIDE HALF-SWITHALF-SWITCHED DUPLEX RECEPTAC PAP PROVIDE - MAS1ER SWITCH FOR CONTROL OF GUEST ROOM LiGHTiNG AND SWITCHED • ` TACLES (EXCLU BATH ROOM AND BALCONY REFER T O WRING DIAGR THIS SHEET. MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC:. VAIL, COLORADO INTERIOR DESIGN SLIEER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.41 ISSUE REVISION DATE OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OE RECORD ■ J Denver, Colorado 002 DD FROG 1 04.1.2.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02,15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD FROG. 2 05.27.05 017 CD FROG. 2R 07.01,05 019 ADDENDUM 10 07.07.05 02 AD 14 07.29.05 045 ASI057 12 -15 -05 058 ASI058 12 -13 -05 m K ILI ail mod• ENI A R GED HOTEL # Cotor, Rumo & Assoc. FILENAME: P:' PROJECTS \200312003 -237 VAIL LipNSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— QELEC2— H— CDE.DWG — E451 PLOT: 12/15/2005 0 4 :01pm REV: 11/29/2005 CAD: nj XREF: gelec2— h— cde.dwg tb.dwg bg2— h— cd.dwg bg2— h— ef,dwg xitg2— hotels— Ida- 151.dwg xltg2— hotels— Ida- 152.dwg furn2.dwg bg2— h— ab.dwg 12— h— ed.dwg 12— h— ef.dwg 12— h— ab,dwg H- 07.dwg (� grA�e _s _n GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 003 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE 004 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 005 CONCRETE SLAB (HATCHED AREA). 01.14.05 2 PERMIT /BID 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. G > 4. PROVIDE ARC INTERRUPTING CIRCUITS IN G GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ALL BEDROOMS PER NEC 210.12(8). ON E- . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL PROVIDE MEDIA CENTER AND (2) 1 C. TO OF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6 OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. d NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL <8 r RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. ��� '�'� NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <0> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. <a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. p m M RECEPTACLE. :D JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED VIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) JLLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO LOCATION. N BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM ARCHITECT PRIOR TO ROUGH -IN. ION BOX FOR 120V CONNECTION TO THERMOSTAT. !ON BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY :QUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. i _ � • > X 81 CC= NOV t14 ONA �� /1 l!ltlfiiWlW 0 OWNER /DEVELOPER NAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado : 1 ?N -7 MASTER PLANNER DESIGN ARCHITECT' HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE ll 2ND & 3RD FLOOR ENLARGED CONDO E ZrAI F• 1 4 =v_n 282/382) TYPICAL PLANS FL OOR ENL SCALE: 1A I N 002 DD FROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 mrwT N PROJECT KEYPLAN ENLARGED CONDOS E & N SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM ' ^ ^ "' " "­ ARCHITECT PRIOR TO ROUGH -IN. P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— QELEC2— C— EN.DWG — E461 PLOT: 02/10/2005 ® 1:57pm REV: 02/10/2005 USER: iro 1 1 E461 L LOCAL LOCAL SWITCHING SWITCHING CIRCUIT HOMERUN MASTER SWITCH MASTER SWITCH W NO SCALE 10 -18 -05 2003 -237 2N D FLOO ENL ARGED CONDO D J � REFE LOAD CENTER NOTE: R EFERENCE PL i CON UN L CENTER LOC 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12 IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM SIC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12 A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42" A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54" A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. i sm • NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET `�.✓' PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MULTI - SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE /DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT_ FLOORING INSET BY FLOORING CONTRACTOR. 3 PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH -IN. \T/ PROVIDE 240V, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH -IN. ' S PROVIDE MEDIA CENTER AT +8' -6 A.F.F. TO BOTTOM AND (2) 2 C. TO TR ROOM DESIGNATED BY ZONES ON "T -100" SERIES DRAWINGS THIS FLOOR. Q OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. /:7 PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN TV. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH -IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48 A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. i INSTALL ELECTRONIC TIMER SWITCH IN -LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. PROVIDE - DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE - ON - MEN DOOR IS OPEN AND - OFF - WHEN DOOR IS CLOSED. <a> CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF - SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH-IN AND MAKE ADJUSTMENTS AS NECESSARY. PROVIDE - MASTER SWITCH FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING PROVIDE HORIZONTALLY MOUNTED CLOCK TYPE RECEPTACLE FOR ELECTRONICS SYSTEM EQUIPMENT. COORDINATE EXACT HORIZONTAL AND VERTICAL LOCATION WITH THE OWNER'S ELECTRONICS CONSULTANT PRIOR TO ROUGH -IN. 2 00 A 2 00A MTG.: FLUSH NEW MAIN CIRCUIT BREAKER VO LTAGE Bus PHASE I PH tip AMPERE SHORT RATED PANEL ii 1 PROVID PR OVID E '_CCT___PH ____CCT .. �KPANELL Refer to Drawing E6 0 0 A for food summar based on NEC ri GENERAL N OTES: PR OVIDE UPDATED DIRECTORIES • INCLUDED PROJECT • f f• s O NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL , S■ PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 081 PR 0063BC 02.01.06 # e i .�� P t 1 , ENLARGED CONDO D Q 2003 42140 ARCHITECTURE, INC. I I OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NffW YORK, NEW YORK STRUCTURALENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, PUMA, AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER DRAQC ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLUZER DESIGNS EDWARDS,COIORADO P: \ARRABELLE \CONDO OWNER REVS \2005 -315 UNIT 274 -2D \CAD \ELEC \P— OELEC2— C —D.DWG — E461B PLOT: 07/24/2006 0 9:15om REV: 07/24/2006 USER: JH 11 E461B 2D -3 2D -3 ZU -1 GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 003 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2, BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE 004 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 005 CONCRETE SLAB (HATCHED AREA). 01.14.05 006 PERMIT /BID 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. ��FLUSH \"/ 4. PROVIDE ARC INTERRUPTING CIRCUITS IN 4 GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION ALL BEDROOMS PER NEC 210.12(8). DETAIL ON E- . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL '�.,.:-�' PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. <6� OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. ^ <✓ NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL < RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <g> 120V CONNECTION FOR RANGE EXHAUST HOOD_ CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18° A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. < g> SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <a> FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. < � HALF SWITCHED RECEPTACLE. <a> CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2" C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. G PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. ,\ oWWWN I l u►1t���� R E f 1 81 cc = ._ X0 0 i r r n I I i W0� OWINER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO .ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIM ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE ° 2D -1" "2D-l' 2ND FLOOR ENLARGED CONDO D 274 PLAN a SCALE: 1 4 =V -0 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 moper N PROJECT KEYPLAN ENLARGED CONDO D P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C -D.DWG - E461B PLOT: 02/10/2005 0 1:56pm REV: 02/10/2005 USER: iro 1 1 E461B P: \ARRABELLE \CONDO OWNER REVS \2005 -318 UNIT 282 -2E \CAD \ELEC \P— QELEC2- C —E.DWG — E461 PLOT. 07/24/2006 0 10:34arn REV. 03/08/2006 USER: JH 2 ND FLO ENLARGED CONDO E (282) PLAN N ai LOAD CENTE REFER TO REFERENCE PLANS O. • i• UNIT LOAD CENTER LOCATIO r/ A MAIIN CIRCUIT BREAKER VOLTAGE / 17 // PR PR OVIDE ARC FAULT TYPE CIRCUIT BREAKER PER NEC 210 .12(B). WrG.: FLUSH 1 0 , 000 AMPERE SHO DESCRIPTION DESCRIPTION I� • : • • . , rte® ®����� i��� ®- �®iYYiiii i � i �® � i �� g,,, �� f.!• 71-/. � 1 .7.yiel.t; ���� ®� t;i��: ���IIII�� ■•. • ■i��T.i�►Til� �AT1��`'i �� T"r' ��i • ' ` i iL"{�. on PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. M 4 lk A RA rel m 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHAH. BE SEPARATED LATERALLY BY NO LESS THAN 12' IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH —IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12' A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42' A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54' A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. = GFCI DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 1 ` PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. ., 2 PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MUL1I— SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE/DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. ` PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH —IN. PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH —IN. PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2' C. TO TR ROOM DESIGNATED BY ZONES ON 'T -100" SERIES DRAWINGS THIS FLOOR. '�✓ OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. '7 PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. '{ PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH —IN. 1 PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48" A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENT'S PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN —LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION NTH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH —IN. PROVIDE "DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE 'ON' WHEN DOOR IS OPEN AND 'OFF' WHEN DOOR IS CLOSED. CEILING MOUNTED LUMINAIRE FURNISHED WITH FF&E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF — SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN AND MAKE ADJUSTMENTS AS NECESSARY. PROVIDE 'MASTER SWITCH' FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING p gC DIAGRAM, THIS SHEET. PROVIDE CONNECTION TO LIGHTOLIER #6351 UNDERCABINET TRACK. PROVIDE ALL NECESSARY ACCESSORIES FOR A COMPLETE INSTALLATION. VERIFY THE QUANTITY AND TYPE OF TRACK FIXTURES WITH OWNER'S INTERIOR ARCHITECT`S PRIOR TO ROUGH —IN. REFER TO INTERIOR ARCHITECT DETAILS FOR ADDITIONAL INFORMATION. PROVIDE WIREMOLD #20GB612 OR EQUAL PLUG STRIP WITH RECEPTACLES AT 12' OC. VERIFY FINISH COLOR WITH INTERIOR ARCHITECT PRIOR TO PURCHASE. INSTALL ON THE UNDERSIDE OF OVERHEAD CABINETS. REFER TO INTERIOR ARCHITECT`S DETAILS FOR ADDITIONAL INFORMATION. PROVIDE WIREMOLD #20GB612 OR EQUAL PLUG STRIP WITH RECEPTACLES AT 12' OC. VERIFY FINISH COLOR WITH INTERIOR ARCHITECT PRIOR TO PURCHASE. INSTALL UNDER THE EDGE OF THE COUNTERTOP. REFER TO INTERIOR ARCHITECT'S DETAILS FOR ADDITIONAL INFORMATION. PROVIDE TIVOH #71010CLLEDWWI DIRECTIONAL LED LIGHT TUBING MOUNTED IN COVE. PROVIDE (1) TRANSFORMER, TIVOLI #SLD- 60- 112V —FC, PER CIRCUIT INDICATED ON PLAN. INSTALL THE TRANSFORMER BEHIND THE COVE MOLDING AND BELOW THE COVE LIGHTS. PROVIDE ALL HARDWARE AND ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION. REFER TO INTERIOR ARCHITECT'S COVE DETAILS FOR ADDITIONAL INFORMATION. PROVIDE ADD ALTERNATE PRICING FOR PEGASUS LIGHTING JPNDSC -4 XENON COVE LIGHT STRIP WITH (4) 5 WATT EXTRA LONG LIFE XENON LAMPS PER FOOT. PROVIDE (1) 600 WATT TRANSFORMER PER CIRCUIT INDICATED ON PLAN (MAXIMUM RUN LENGTH OF 30` -0' PER TRANSFORMER) — LIVING ROOM COVE (2E- 34,36). DINING ROOM COVE (2E- 38,40), BEDROOM COVE (2E- 42,44). PROVIDE ALL HARDWARE AND ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION. REFER TO INTERIOR ARCHITECT`S COVE DETAILS FOR ADDITIONAL INFORMATION. INCREASE WIRE SIZE AS NECESSARY FOR VOLTAGE DROP FOR REMOTE TRANSFORMER INSTALLATION. 2 003 M ARCHITECTURE, hk �vK k Eh l} 44 4. S': R h OWNER /DEVELOPER V.A..IL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RI.CORD J xFtCNLIEC:tLJRE Denver, Colorado MASTER PLANNER DESIGN ARCIIITECr HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO AI RP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER,COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIIER DESIGNS EDWARDS, COLORADO PROJECT NUMBER 20826.01 ISSUE REVISION DATE 102 PR 0084BC 02.17.06 Y".,OJEiGT N PROJECT KEYPLAN P:\ARRABELLE\CONDO OWNER REVS \2005 -231 UNIT 217 -2N \CAD \ELEC \P— OELEC2— C —N.DWG — E461 PLOT: 08/03/2006 0 11:06om REV: 03/17/2006 USER: jh NEMA 14 -50R 2N -8,10 2N -2 ELEV 16 E216 I I F LOOR ENLARGED CONDO N (217) PLAN N f r" 1111111111 ► 111111111 !► ,► ► raud- 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12" IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM SIC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500,6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4, PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7, REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12" A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42' A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54' A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. t � • i NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE WHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. }2 PROVIDE HUBBELL 0SFBSS OR EQUAL RECESSED METALLIC MUL11- SERVICE FLOOR, BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE /DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. '3 PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH -IN. 4,y PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH -IN. PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2' C. TO TR ROOM DESIGNATED BY ZONES ON 'T -100' SERIES DRAWINGS THIS FLOOR, OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. 8. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT: REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH -IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48' A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN -LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES, VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH -1N. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. PROVIDE "DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE "ON" WHEN DOOR IS OPEN AND 'OFF" WHEN DOOR IS CLOSED. a> CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF - SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN AND MAKE ADJUSTMENTS AS NECESSARY. <�> PROVIDE "MASTER SWITCH' FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET, A PR, 941 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD �j ARCHTECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART } HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON COLORADO MEPENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVILENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NU.Mt BER: ISSUE REVISION 20826.01 DATE 111 PR 0094BC 03,03.06 1 130 PR 0094BC -R1 03.17.06 PROJECT KEYPLAN JI '2F -; < > SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. < FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> HALF SWITCHED RECEPTACLE. `� CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1/2' C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCA11ON WITH ARCHITECT PRIOR TO ROUGH -IN. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. 1 `> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. ap RED; , Q -V3 2006 NAL OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado '2F -34' MASTER PLANNER & DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGNEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 NECESSARY. NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL < ' RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <a> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. \Y MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18' A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. 2ND & 3RD FLOOR ENLARGED CONDO a SCALE:1 4 " =1' -0" PRO)SCr N PROJECT KEYPLAN ENLARGED CONDO F F (284 /384) TYPICAL PLAN GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE <D> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. CONCRETE SLAB (HATCHED AREA). z 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. < � > � GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). \T/ DETAIL ON E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL <'> PROVIDE MEDIA CENTER AND (2) 1° C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL < ' RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <a> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. \Y MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18' A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEV LLOPMENT \CAD \DDS \ELEC \P- QELEC2- C -F.DWG - E462 PLOT: 02/10/2005 ® 1:56pm REV: 02/10/2005 USER: iro 11 E 4 62 GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD FROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. <� PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD PROG SET 01.14.05 006 CONCRETE SLAB (HATCHED AREA). 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. � < ' 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). <�> GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. < �> PROVIDE MEDIA CENTER AND (2) 1 C. TO IDF ROOM THIS FLOOR. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT <✓> OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. Q NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR <� RECEPTACLE MOUNTED HORIZONTALLY, 6 BELOW FINISHED COUNTER TOP. RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. <, 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH -IN. <a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18 A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. � SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <� FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> HALF SWITCHED RECEPTACLE. <� CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2" C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. <a FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. �!✓ PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS MATH TUB MANUFACTURER PRIOR TO ROUGH -IN. AA AAAkill 1 1iiiji lil QO RE�s`' %,,� 1 • •• % Lr 2 Nov J (vA \ ' ��� 1 1lf1lllti \ \ \ � \ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ,GFI ARCHITECT OF RECORD -1 a - I ii » 2G -1 I I Denver, Colorado MASTER PLANNER DESIGN ARCHPIT.CI' HART HOWERTON ,GFI NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 2ND & 3RD FLOOR ENLARGED CONDO G b SCALE:1 4 =1' -0" 287/387) TYPICAL PLAN Pkojwr N PROJECT KEYPLAN ENLARGED CONDO G P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C -G.DWG - E463 PLOT: 02/10/2005 ® 1:56pm REV: 02/10/2005 USER: iro GENERAL NOTES: DETAIL NOTES THIS SHEET: I . PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD PROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2, BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE 06.21.04 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD PROG SET SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 006 CONCRETE SLAB (HATCHED AREA). 02.1 5.05 Q 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. Q PROVIDE � GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON E- 4. ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. ��� \v/ OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN_ MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS ��� NECESSARY. `�:--' NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL <g> RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. � NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <g> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. <� MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. <✓ SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. \% FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. HALF SWITCHED RECEPTACLE. <- CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION MATH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2" C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <: > PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <� PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. REGj �_103� �� VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCM;LAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.1 5.05 2ND FLOOR ENLARGED CONDO J b SCALE: 1 4" =1' -0" 1• • N � 272) PLAN ENLARGED CONDOS C & J P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C- CJ.DWG - E464 PLOT: 02/10/2005 ® 1:55pm REV: 02/10/2005 USER: iro 11 E464 b/ 2ND, 3RD & 5TH FLOORS ENLARGED CONDO L 243/343/543 GENERAL NOTES: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. DETAIL NOTES THIS SHEET: NOTE; NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). FLUSH DUPLEX FLOOR RECEPTACLE. 3 � GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION "3> DETAIL ON E- < 5� > PROVIDE MEDIA CENTER AND (2) 1 C. TO IDF ROOM THIS FLOOR. <6 > OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. NOT USED. RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. <, NOT USED. <0> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH -IN. `a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. <1 SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <g> FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. `1> HALF SWITCHED RECEPTACLE. Q CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2" C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. 1 PROVIDE JUNCTION BOX FOR 120V CONNEC11ON TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. \\��tii1u �rri,rrrrr /rr Op REGj %, "iioiC� •••'` ..... • ` ENLARGED CONDO TYPICAL PLAN P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C -L.DWG - E4648 PLOT: 02/10/2005 ® 1:55pm REV: 02/10/2005 USER: iro 1 1 E 4 6 4B GENERAL NOTES; DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD FROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE '1 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD PROG SET SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 006 CONCRETE SLAB (HATCHED AREA). 02.15.05 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. � PROVIDE Q GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLA11ON DETAIL ON E- 4. ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(6). . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL PROVIDE MEDIA CENTER AND (2) 1" C. TO OF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. < 6 > OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. � <:> NOT USED. 7. PROVIDE SWITCH ON WAIL ADJACENT TO RESTROOM LIGHT SN TCH(ES) FOR CONTROL <, RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <t 120V CONNEC11ON FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. � TO ROUGH -IN. i MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18' A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <a> FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. HALF SWITCHED RECEPTACLE. CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. \% FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. \ \\\\P i `R G,s : gip • �,:�+; -0 7 /// OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado 14-50R "2M- 8,10" MASTER PLANNER DESIGN ARCHITECT HART ! HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVII, ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 i �u 2ND FLOOR ENLARGED CONDO K SCALE: 1/4"=V- -0 255) PLAN NENA 14 -30R, +36' '2M- 16,18' +36" "2M- 16,18" AC,GFI - DW "2M -1" "2M -1" "2M -1" "2M-l' "2M -1' 2ND FLOOR ENLARGED CONDO M (229) PLAN p SCALE: 1/4"=V-0" ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 PROJEa N PROJECT KEYPLAN ENLARGED CONDOS K & M P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C- KM.DWG - E465 PLOT: 02/10/2005 0 1:54pm REV: 02/10/2005 USER: irc 11 E465 NEW PANEL 2K 00 A MAIN CIRCUIT BREAKER VOLTAGE 120 1 240 V 00 A BUS PHASE I PH Panel Notes: WIRE 4 W 11. PR CIRCUIT BREAKER. PR 10, 000 AMPERE SHORT RATED �►I:ii7ilSiZlLiLl:iLi s • • �iLii3i'f��1:f,��iii3i�Yi�� • • • r i�di�� ®� •r v s • ® ® ® ®�� �� iS ®���� • • IMr� - I Lk summary based on PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. P: \ARRABELLE \CONDO OWNER REVS \2005 -232 UNIT 255 -2K \CAD \ELEC \P— OELEC2— C —K.DWG — E465 PLOT: 08/03/2006 0 11:07om REV USER: jh = GF ' =Sl NOTE: i�! Iii 1 i i• i• i i•! ! i •. R EFER 2ND FLOOR ENLARGED' CONDO K (255) PLAN SCALE: 1A LOAD CENTER NOTE: T P L A NS i. C ONDO UNIT LOAD CENTER LOCATIO 1 ENEFxAL NOTES, 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12' IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH —IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS, 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12' A.F.F. TO CENTER, HORIZONTAL, B. SWITCHES AT +427 A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54' A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. DETAIL NO TES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MUL11— SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE /DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH —IN. PROVIDE 240V, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH—IN. `�✓` PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2" C. TO TR ROOM DESIGNATED BY ZONES ON "T -100" SERIES DRAWINGS THIS FLOOR. "�-- OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. �7 PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP, VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH —IN, PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH —IN. -' PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48' A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH 1N —LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH —IN. PROVIDE 'DOOR JAMB' SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE "ON" WHEN DOOR IS OPEN AND 'OFF' WHEN DOOR IS CLOSED. 1� CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF — SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN AND MAKE ADJUSTMENTS AS NECESSARY. 1 } PROVIDE "MASTER SWITCH" FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET. PROVIDE WEATHERPROOF JUNCTION BOX AT +18' AFF FOR CONNECTION OF FUTURE HOT TUB. ROUTE 1" CONDUIT FROM JUNCTION BOX TO CONDO UNIT LOAD CENTER. PROVIDE RECESSED CLOCK TYPE RECEPTACLE HORIZONTALLY MOUNTED ABOVE FIREPLACE FOR CONNECTION OF TV. COORDINATE MOUNTING HEIGHT OF RECEPTACLE AND TV OUTLET WITH INTERIOR ARCHITECT PRIOR TO ROUGH —IN. OWNBR/DEVELOPER R ESORTS VAIL COMP !I AVON OF • . *A11:.1r Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK„ NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVILENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SIMPER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 111 PR 0094BC 03.03.06 130 PR 0094BC -R2 03.17.06 nojwr PROJ K • �r M ENL NN�, 3RD FLOOR P NINE 11 ik 01,21111 �01`11 : rougg 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12' IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTMS 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. B. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12" A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42" A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54" A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. yawam - E 0 9 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET /tom` PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MUL11- SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE/DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. < PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH -IN. < 4�, > PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH -IN. PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2 C. TO TR ROOM DESIGNATED BY ZONES ON ° T -100' SERIES DRAWINGS THIS FLOOR. OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. '`�✓' RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH -IN. g` PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH -IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48 A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN -LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. PROVIDE "DOOR JAMB' SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE "ON" WHEN DOOR IS OPEN AND "OFF" WHEN DOOR IS CLOSED. > CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF- SWITCHED DUPLEX RECEPTACLE. < > PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN AND MAKE ADJUSTMENTS AS NECESSARY. PROVIDE 'MASTER SWITCH'" FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET. .,, • 00 NEW MAIN CIRCUIT BREAKER VOLTAGE , ll AMPERE SHORT RATED P PR PR OVID E ' ®I� • • • ' ��Yiiiiil� ' ' �iiii�i�® r • ®fi�iii��� ��,����r���� ����••��,•��� I I IT 1-7711 • r Refor to D rawing N OTES: GENERAL P ROVI DE •t• r PANEL DIRECT ORIES •' PANELS THAT ARE INCLUDE IN THIS P ROJECT . PROVIDE r D ESCRIPTIONS NEW CIRCUITS BEING INSTALLE IND ICATE ACCESS Val N O NEW LOAD A DDED TO THIS UNIT'S !'# CENTER PANEL SCHE SH OWN i' INFORMATION ONLY ` T O TYPICAL LOAD CALCULATIO SHEET E 600 . 4 , ISSUED UNDER BA BUILDING • `t DO CUMENTS. OWNER/DEVELOPER NAIL RESORTS DEVELOPMENT COMPANY .AVON, COLORAD ARCHITECT OF RECORD r , ARCHITECTURE Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL,, COLORADO INTERIOR DESTGN SLSFER DESIGNS EDWARDS, COLORADO ISSUE REVISION DATE 111 PR 0094BC 03.03.06 PROJ N P: \ARRABELLE \CONDO OWNER REVS \2005 -233 UNIT 372 -3C \CAD \ELEC \P— QELEC3— C —C.DWG — E466 PLOT: 08/03/2006 0 11:07om REV: 03/17/2006 USER: ih U E 466 - C -V,VI I P\V,VI 7 1___j GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD PROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE 06.21.04 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD PROG SET SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 006 CONCRETE SLAB (HATCHED AREA). 02.15.05 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. ^ 4. PROVIDE ARC INTERRUPTING CIRCUITS GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON E- IN ALL BEDROOMS PER NEC 210.12(6). . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL n PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. � NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL �8�} RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. <2> NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <g> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. Q MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <a> FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. \Y' HALF SWITCHED RECEPTACLE. i b CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2" C NTH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. <9> FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <' > PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. ti` '�` • UG �` : ;� v: 9-7 ; oC (ON 4t � �Illltt1111! OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL. ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SAFER DESIGNS EDWARDS, COLORADO PROJECT" NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 "3D -40" ,30 AC,GFI �u 3RD FLOOR ENLARGED C >CALE: 1 4" =1' -0" ENLARGED CONDOS D P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC3- C -D,DWG - E467 PLOT: 02/10/2005 ® 1:54pm REV: 02/10/2005 USER: iro 11 E467 P: \ARRABELLE \CONDO pWNER REVS \2005 -227 UNIT 382 -3E \CAD \ELEC \P— pE�EC3— C —E.pWG _ E467 PLOT: 02j0Ij2p06 a9 2:42pm REV: 02jpt /2p06 USER: � 3E -15 3E -17 AC,GF1 FX��3 k 0 11 3E -3 EX'1 /A481 3E -7 ENTRY ..378.01 3E -23,25 4 -- - -- -__ -15 11 3E -19,21 RFL4 3 15 E - b FI !H 3E -13 PR5 8 SDL3 SDL3 RFL1 3E - ��t 4 E -17 3E -17 I 3L-17 0 3E -17 a r� » _ RFi CLOSET 382.33 E3 3E f .C.0 Tj 3E-17 r CLOSET ..382.35 3E_g 3E -26 -3E --t5- _ 3E -13 PR5 8 SDL3 SDL3 RFL1 3E - } E -17 3E -17 I 3L-17 0 3E -17 _ RFi CLOSET 382.33 E3 3E f .C.0 Tj 3E-17 -.. rim 17 1 17 j L AC,GFI ( 3E -30 3E -32 3E -32 l 0, RFL1 j 3E -32 3E -30 I El ' II _i 1 4 3E -28 4 t RFL1 } 3E -33 7 : 3E -2 3E -26 . S a N - � 3E -32 RFL1 X1 3E -32 3E IN ISN Vw PERM RFL1 �r RFL1 3E- I, Ott wit �Yar�1�l i �A_ •, 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12' IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814,. UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.5. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS. A. RECEPTACLES AT +12' A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42' A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54' A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. RALI 3E -7 GUEST ROO 3E -9 3E -5 !ik i ll i l! Iki kli i ll ikk ii ill ki RAL2 r 3E -7 • �4 i 3E -5 E -9 tr 3E -9 IA NOTE. NOT ALL NOTES MAY BE USED ON EACH SHEET 1^ PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. PROVIDE HUBBELL #3$FBSS OR EQUAL RECESSED METALLIC MULTI- SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE/DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. �> PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH -IN. <r. > PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH -IN. 'C'" PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2 C. TO TR ROOM DESIGNATED BY ZONES ON "T -100" SERIES DRAWINGS THIS FLOOR. Q OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V: CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE JUNC11ON BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. <a> PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH -IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48' A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN -LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. 'i PROVIDE FLUSH JUNCTION BOX AND 120Y CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. G PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN. PROVIDE 'DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE "ON" WHEN DOOR IS OPEN AND 'OFF' WHEN DOOR IS CLOSED. CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF - SWITCHED DUPLEX RECEPTACLE. 1 PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN AND MAKE ADJUSTMENTS AS NECESSARY. q> PROVIDE 'MASTER SWITCH' FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET. PROVIDE RECESSED CLOCK TYPE RECEPTACLE ABOVE FIREPLACE FOR CONNECTION OF TV. REFER TO INTERIORS PLANS FOR MOUNTING HEIGHT AND ADDITIONAL INFORMATION. PROVIDE ROUGH -IN, INCLUDING BACK 80X, WIRING, AND CONTROLS, FOR WALL SCONCE. REFER TO INTERIORS DRAWINGS FOR EXACT LOCATION AND MOUNTING HEIGHT. SCONCE FURNISHED BY OWNER. COORDINATE RECEPTACLE LOCATION AND MOUNTING HEIGHT WITH ELECTRONICS EQUIPMENT LOCATION PRIOR TO ROUGH -IN AND MAKE ADJUSTMENTS AS NECESSARY. COORDINATE WITH OWNER'S ELECTRONICS SYSTEM INSTALLER. PROVIDE CEILING MOUNTED RECESSED CLOCK TYPE RECEPTACLE FOR CONNECTION OF A/V EQUIPMENT. COORDINATE EXACT LOCATION WITH OWNER'S ELECTRONICS CONSULTANT PRIOR TO ROUGH -IN. L LOCAL LOCAL SWITCHING SWITCHING CIRCUIT HOMERUN MASTER SWITCH t �► tit BREAKER ACCESSORIES PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. PROVIDE TYPED DESCRIPTIONS OF * = GFCI NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL " LOAD CENTER NOTE: REFER TO REFERENCE PLANS FOR CONDO} UNIT LOAD CENTER LOCATIONS. OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J 1 �j ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRIUTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR.R AND ASSC'CIAATF,S Cq DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUNMER: 20826.01 ISSUE REVISI DATE 075 PR 0056BC 02.01.06 0. • : �1. �.. . ♦ �...' 0 .01 r. � �'i-r 1J�.�► .. '� 7'iT�'� /�[�� �i,�W�1...�11�1 . / \'llllll�,��' a,�i.`� ®_��� ® O.r h. �. i�I1111�r��ll�i�r l.Y.rlr�.itrrliilt� L��Fi��� ®�® � OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD J 1 �j ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRIUTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR.R AND ASSC'CIAATF,S Cq DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SUPER DESIGNS EDWARDS, COLORADO PROJECT NUNMER: 20826.01 ISSUE REVISI DATE 075 PR 0056BC 02.01.06 0. GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. CONCRETE SLAB (HATCHED AREA). 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. <i> 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). �� <. > GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL <�> PROVIDE MEDIA CENTER AND (2) 1 C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -1N. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. Q NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SNTCH(ES) FOR CONTROL < RECEPTACLE MOUNTED HORIZONTALLY, 6 BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. �9J NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. �'' 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH -IN. <a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18 A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. HALF SWITCHED RECEPTACLE. <a> CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2 C WITH PULLSTRING FOR POWER AND (1) 1/2 C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. \% FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <� PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. 3RD FLOOR ENLARGED CONDO L SCALE: 1/4"=V-0" N(% D r 1 cc IN' ! littt1111W \ \� ENLARGED CONDO L Cotor, Rumo & Assoc. FILENAME: P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— QELEC3— C —L.DWG — E468 PLOT: 02/10/2005 @ 1:53pm REV: 02/10/2005 CAD: iro XREF: H- 07.dwg gelec3— c —l.dwg tb.dwg bg3— c —I.dwg 13— c —i.dwg LO— closet.dwg MB- 04.dwg furn3.dwg 11 E468 "3K -40' GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD PROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE <> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD PROG SET SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 006 CONCRETE SLAB (HATCHED AREA). 02.15.05 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH —IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL NEC 210.12(6). ON E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. ��� < > OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH —IN, MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. <�> NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCHES) FOR CONTROL RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <� 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH —IN. <g> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18 A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. �1 FLUSH JUNCTION BOX FOR 120V CONNECTON TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. HALF SWITCHED RECEPTACLE. CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. < 9> FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. Q PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <'✓ PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN. 0 111l1l11111// =U; -0 71 Cr= 2 � t tttllillllWW W �� ` OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 PRo,W-r N PROJECT KEYPLAN ENLARGED CONDO K P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC3- C -K.DWG - E4688 PLOT: 02/10/2005 ® 1:53pm REV: 02/10/2005 USER: iro 11 E4 68B Po+ GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. CONCRETE SLAB (HATCHED AREA). 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. \ GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). DETAIL ON E- . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL <5 PROVIDE MEDIA CENTER AND (2) 1 C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. ��� < " > OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. <�> NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCHES) FOR CONTROL <�> RECEPTACLE MOUNTED HORIZONTALLY, 6' BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <g> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18' A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. <1 SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <> FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. HALF SWITCHED RECEPTACLE. CEILING MOUNTED JUNCTION BOX FOR POWER CONNEC1ON TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2 C WITH PULLSTRING FOR POWER AND (1) 1/2 C FOR CONTROLS BACK TO 3RD, 4TH & 5TH FLOOR ENLARGED CONDO M & N SCALE: 1/4"=V-0 Y '3M -12' 50R VowlII tIi111l /1121 =U; - 97 CC = • ;, t�lt3,: w • o ���lillIIIIV1�t`� ENLARGED CONDO M & N 329/429/529) TYPICAL PLANS P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC3- C- MN.DWO - E469 PLOT: 02/10/2005 0 1;53pm REV: 02/10/2005 USER: iro 11 E469 i N OTES 1. THESE • CONDO ! FOR •i } SHALL BE } • r i } r NO • t • R 2- REFER T O ARCHITECTURAL PLAN A056 FOR ARC H17ECTURAL UNITS. LOCATION FOR ALL WRING DEVICES SHOWN SHALL BE ADJUSTED TO ACC OMMODATE ARCHITECTURAL CHANG 3. MOUNTING HEIGHTS FOR ALL WRING DEVICES SHALL BE MODIFIED TO MEET CURRENT A DA STANDARDS AND GUID ELINES. 4. PROVIDE UNSWITCHED DUPLEX RECEPTACLE s - • F OR TTY PH O NE. REFER T T SERIES DRAWNGS FOR LOCATION OF s • C • AD JACEN UNSWITCHE RECEPTACLE C i P R OVI DE D WTH VISUAL RING ANN OUNCEMENT • E QUIPMENT 5. PROVIDE 120V CIRCUIT FROM NEAREST UNSWTCHED RECEPTACLE FOR DOORBELL. DOORBELL TO BE SPECIFIED BY INTERIOR DESIGNER. PROVIDE AND INSTALL DESK RECEIVER AND STROBE TO ANNUNCIATE DOOR BELL — ONE FOR EACH SLEEPING ROOM, ONE FOR GREAT ROOM, AND ONE FOR MASTER AND SECONDARY } • MERCHANTS i OR -• BATHROOM. I EQ UAL 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12" IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED NTH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM, REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH —IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12" A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42' A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54' A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E- WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. p � I - 0 m m -, IA fmill I milk Egg am gifflOrm NOTE. NOT ALL NOTES MAY BE USED ON EACH SHEET <.'. -' PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT JINTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. <�> PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MULTI — SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE/DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER), VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH —IN. 4 PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH —IN. 5 PROVIDE MEDIA CENTER AT +8' -6' A.F.F. TO BOTTOM AND (2) 2' C. TO TR ROOM DESIGNATED BY ZONES ON 'T -100' SERIES DRAWINGS THIS FLOOR, ' 6 OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH —IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48" A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH —IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SNATCH IN—LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH —IN. PROVIDE "DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE 'ON' WHEN DOOR IS OPEN AND 'OFF" WHEN DOOR IS CLOSED. CEILING MOUNTED LUMINAIRE FURNISHED WITH FF&E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF — SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB, VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN AND MAKE ADJUSTMENTS AS NECESSARY. PROVIDE "MASTER SWITCH" FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO HARING DIAGRAM, THIS SHEET. OV`NER /DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT" OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORE, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS,COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE Dim i& F i P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P— QELEC3— C —U.DWG — E469B PLOT, 12/15/2005 0 4 :24pm REV: 11/30/2005 USER: nj 3RD FLOOR ENL ARGED CONDO U Mi7M L OAD CENTER NO TE: . •- 0 al IN 0 , 1 1 , 111 a .. •. W41 61, 4 11 !• iNVER ! a • • 0 002 DD PROG 1 04.12.04 003 DD FROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 007 PERMIT REV 03.24.05 008 PERMIT REV 04.07.05 011 ADDENDUM 4 05.27.05 012 CD FROG. 2 05.27.05 017 CD PROD. 2R 07.01.05 019 ADDENDUM 10 07.07.05 023 ADDEND 14 07.29.0 045 AS1057 12 -15 -05 058 ASI058 12 -13 -05 PROJECT 4 ' �r ENLARGED CONDO U BALCONY BALCONY 330.62 1 330.63 OWER RECEPTACLE. GHTED MIRROR. CONFIRM IECTION TO MOTORIZED 3OR TO ROUGH -IN. PROVIDE (1) ' C FOR CONTROLS BACK TO _AT SCREEN T.V. CONFIRM THERMOSTAT. WHIRLPOOL TUB. VERIFY ER PRIOR TO ROUGH -IN. , , ` ,,lillititIII,, // PO REGIsA�''% 19 81 .A � � � /llIi111 OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER DESIGN ARCHTIECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS 4 GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON IN ALL BEDROOMS PER NEC 210.12(6). E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL <�> PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. G 6] OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. ^ �/ 2ND FLOOR ENLARGED CONDO Y 201 PLAN b SCALE: 1 4 " =1' -0" moJacr N PROJECT KEYPLAN ENLARGED CONDO Y GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52, NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE \�% PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. CONCRETE SLAB (HATCHED AREA). 2 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS 4 GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON IN ALL BEDROOMS PER NEC 210.12(6). E- 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL <�> PROVIDE MEDIA CENTER AND (2) 1" C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. G 6] OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. ^ �/ NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL < 8 > RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. �g� NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET <a> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. <fj> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. P:\PROJECTS\2003\2003-237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC2- C -Y.DWG - E470 PLOT: 02/10/2005 ® 1:52pm REV: 02/10/2005 USER: iro 11 E470 GENERA NOTES: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210A2(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SwTCH(ES) FOR CONTROL OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNEC11ON TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). FLUSH DUPLEX FLOOR RECEPTACLE. 3 GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION Q DETAIL ON E- �5''` PROVIDE MEDIA CENTER AND (2) 1° C. TO IDF ROOM THIS FLOOR. <� OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. Q NOT USED. � RECEPTACLE MOUNTED HORIZONTALLY, 6' BELOW FINISHED COUNTER TOP. <'> NOT USED. 'a> 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH -IN. MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18 A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. \% SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. <'✓ FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> HALF SWITCHED RECEPTACLE. 1�5 CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1d2' C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. <a FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. REGj :CC= ���f��rr111►�1������ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON,COLORADO ARCHITECT OF RECORD Denver, Colorado MASTERPLANNER DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NU\BER: 20826.01 ISSUE REVISION DATE 3RD FLOOR ENLARGED CONDO Y )GALE. 1/4"=1 '_0 301) PLAN 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 ENLARGED CONDO Y P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC3- C -Y.DWG - E471 PLOT: 02/10/2005 ® 1:52pm REV: 02/10/2005 USER: iro 11 E471 NEMA 1 +36 +3E 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12" IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE €00% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM SIC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(B). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8. WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS: A. RECEPTACLES AT +12" A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42" A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54" A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. SE m -- 1. THESE NOTES SHALL APPLY TO CONDO UNIT 3B/368 FOR ADA ACCESSIBILITY, AND SHALL BE USED IN CONJUNCTION WITH OTHER GENERAL AND DETAIL NOTES LISTED ON DRAWING. 2. REFER TO ARCHITECTURAL PLAN A056 FOR ARCHITECTURAL CHANGES IN ACCESSIBLE UNITS. LOCATION FOR ALL WIRING DEVICES SHOWN SHALL BE ADJUSTED TO ACCOMMODATE ARCHITECTURAL CHANGES. 3. MOUNTING HEIGHTS FOR ALL WIRING DEVICES SHALL BE MODIFIED TO MEET CURRENT ADA STANDARDS AND GUIDELINES. 4 • PROVIDE UNSWITCHED DUPLEX RECEPTACLE AT UNIT TELEPHONES FOR TTY PHONE. REFER TO T SERIES DRAWINGS FOR LOCA11ON OF TELEPHONES. CIRCUIT TO ADJACENT UNSWITCHED RECEPTACLE CIRCUIT. PHONE SHALL BE PROVIDED WITH VISUAL RING ANNOUNCEMENT (BY OWNER). 5- PROVIDE 120V CIRCUIT FROM NEAREST UNSWITCHED RECEPTACLE FOR DOORBELL. DOORBELL TO BE SPECIFIED BY INTERIOR DESIGNER. PROVIDE AND INSTALL DESK TOP RECEIVER AND STROBE TO ANNUNCIATE DOOR BELL - ONE FOR EACH SLEEPING ROOM, ONE FOR GREAT ROOM, AND ONE FOR MASTER AND SECONDARY BATHROOM. EQUIPMENT MANUFACTURED BY PHONE MERCHANTS, NUTONE, OR APPROVED EQUAL. u'111TiFT'i7:Ct , t'it 4L NOTES: )E NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. PROVIDE TYPED DESCRIPTIONS OF w GFCI OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD ARCHITECTURE Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART' HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VATL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUTMBER: 20826.01 N O NEW L OAD ADDED TO THIS UNIT'S LOAD CENTER. PANELBOARD SCHEDULE SHOWN F OR INFORMATION ONLY • T O TYPICAL LOAD CALCULATIO SHEET E 600 . 4 , ISSUED UND BUIL DING i 'A Di ISSUE REVISION DATE 111 PR 0094BC 03.03.06 P: \ARRABELLE \CONDO OWNER REVS \2005 -308 UNIT 472 -4C \CAD \ELEC \P- OELEC4- C -C.DWG - E472 PLOT. 06/03/2006 0 11:09om REV: 03/17/2006 USER: jh L OAD CENTER NOTE: REFER T F OR C ONDO UNIT LOAD CENTER LOCATIO pLAN REVIEW APPROVAL PR9 Q u mmmommum NEW PANEL 4C 200 A MAIN CIRCUIT BREAKER VOLTAGE 120 1 240 V 200 A BUS PHASE 1 PH WIRE 4 W E: !.:FLUSH 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) NOTE_ NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. ,2 PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MUL11— SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE /DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH —IN. < 4 > PROVIDE 240V, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH —IN. PROVIDE MEDIA CENTER AT +8' -6" A.F.F. TO BOTTOM AND (2) 2° C. TO TR ROOM DESIGNATED BY ZONES ON "T -100' SERIES DRAWINGS THIS FLOOR. �-' OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. <:2> PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH —IN. \Y PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48" A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH —IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN -LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH -IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH —IN. PROVIDE - DOOR JAMB" SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE "ON" WHEN DOOR IS OPEN AND "OFF" WHEN DOOR IS CLOSED. `-' CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF — SWITCHED DUPLEX RECEPTACLE. PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN AND MAKE ADJUSTMENTS AS NECESSARY. PROVIDE "MASTER SWITCH" FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET. Panel Notes: 1. PROVIDE GFCI CIRCUIT BREAKER. 2. PROVIDE ARC FAULT TYPE CIRCUIT BREAKER PER NEC 210.12(B). mogrr PROJECT KEYPIAN GENERAL NOTES: DETAIL NOTES THIS SHEET: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. DD PROG 2 NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE 06.21.04 PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CD FROG SET SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6, 006 CONCRETE SLAB (HATCHED AREA). 02.15.05 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW FLUSH DUPLEX FLOOR RECEPTACLE. VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. Q PROVIDE ARC CIRCUITS GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION DETAIL ON E- 4. INTERRUPTING IN ALL BEDROOMS PER NEC 210.12(B). . 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL PROVIDE MEDIA CENTER AND (2) 1 C. TO IDF ROOM THIS FLOOR. CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT WITH ARCHITECT PRIOR TO ROUGH -IN. MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS < 7 NECESSARY. NOT USED. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCH(ES) FOR CONTROL <g> RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. NOT USED. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET �1�(S > 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. TO ROUGH -IN. < a> MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE. FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. HALF SWITCHED RECEPTACLE. t� CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1/2" C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. Q PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. tea'" PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. RE �sj''' cr- ` : off,. H(1g •'�'• �� , $ 1�{ w _ Off, ;.!Zz \ NA\ OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado NEN MASTER PLANNER & DESIGN ARCHITECT HART I HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON, COLORADO MEP ENGINEERS CATOR, PUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 "4C ISSUE REVISION DATE 002 DD PROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD FROG SET 01.14.05 006 PERMIT /BID 02.15.05 4TH & 5TH FLOORS ENLARGED CONDO E SCALE: 1/4"=V-0" 4TH & 5TH FLOORS ENLARGED CONDO D 476/576 TYPICAL PLANS G! SCALE: 1/4"=V-0" �N PROJECT KEYPLAN ENLARGED CONDOS D & E roffm P: \PROJECTS \2003 \2003 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \ELEC \P- QELEC4- C- DE.DWG - E473 PLOT: 02/10/2005 @ 1:51pm REV: 02/10/2005 USER: iro 11 q' � 11 ' 1 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED_ OPPOSING UNIT ELECTRICAL RECEPTACLE BOXES AND BOX PENETRATIONS SHALL BE SEPARATED LATERALLY BY NO LESS THAN 12' IN SEPARATE STUD CAVITIES SEPARATED BY A VERTICAL METAL STUD. EACH ELECTRICAL BOX SHALL BE 100% SEALED WITH A FIRE RATED (ASTME 814, UL 1479) PUTTY BACKING PAD HAVING A MINIMUM STC RATING OF 41 (STC -41). SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH —IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK —OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(6), 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. REFER TO REFERENCE ELECTRICAL PLANS FOR LOCATION OF CONDO UNIT PANELS. 8- WIRING DEVICE MOUNTING HEIGHTS SHALL BE TYPICAL AS FOLLOWS_ A. RECEPTACLES AT +12" A.F.F. TO CENTER, HORIZONTAL. B. SWITCHES AT +42` A.F.F. TO CENTER, EXCEPT WHERE ADJACENT TO BEDS. C. THERMOSTATS AT +54" A.F.F. TO CENTER. D. RECEPTACLE, SWITCH, AND THERMOSTAT MOUNTING HEIGHTS SHALL MEET ADA REQUIREMENTS IN ADA ACCESSIBLE ROOMS. E. WHEREVER POSSIBLE, LIGHT SWITCHES, RECEPTACLES, AND /OR THERMOSTATS SHALL BE STACKED VERTICALLY. F. REFER TO INTERIOR DESIGN DRAWINGS FOR MOUNTING HEIGHT OF SWITCHES LOCATED ADJACENT TO BEDS AND ANY OTHER SPECIAL CONDITIONS. A PR94 C 1' V— V ftW We ��J'- +�tttttit 3 Litt 1// 11111111t1 " "; OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AV COLORADO ARCHITECT OF RECORD ■ J ARCHITECTURE Denver, Colorado MASTER PLANNER DESIGN ARCHITECT HART (HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGINEER MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VA14 COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUINIBER: 20826.01 P: \ARRABELLE \CONDO OWNER REVS \2005 -309 UNIT 482 -4E \CAD \ELEC \P- OELEC4- C -E.DWG - E473 PLOT: 08/03/2006 0 11:09om REV: 03/17/2006 USER: jh i 4TH FLOOR ENL ARGED CONDO PUTUMNIUMW r ♦ , CENTER NOTE: r • T O R EFE R ENCE P • CONDO UNIT LOAD CENTER LOCATIONS. t � • NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET \% PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). PROVIDE NUHEAT OR EQUAL ELECTRIC FLOOR MAT AND PROGRAMMABLE THERMOSTAT #NTG5110. REFER TO ELECTRIC FLOOR MAT DETAIL, SHEET E500.2 FOR ADDITIONAL INFORMATION. '�✓ PROVIDE HUBBELL #3SFBSS OR EQUAL RECESSED METALLIC MULTI — SERVICE FLOOR BOX WITH FLUSH COVER DUPLEX RECEPTACLE AND VOICE/DATA OUTLETS. FLUSH COVER COLOR BY ARCHITECT. FLOORING INSET BY FLOORING CONTRACTOR. '`ter -> PROVIDE JUNCTION BOX FOR SINGLE POINT CONNECTION OF GAS FIREPLACE (ELECTRONIC IGNITION AND BLOWER). VERIFY CONNECTION REQUIREMENTS WITH FIREPLACE MANUFACTURER PRIOR TO ROUGH —IN. < 4 > PROVIDE 24OV, 3OA2P DISCONNECT SWITCH FOR CONNECTION OF STEAM SHOWER. VERIFY CONNECTION REQUIREMENTS WITH SHOWER MANUFACTURER PRIOR TO ROUGH —IN. -.�- -' PROVIDE MEDIA CENTER AT +8' -6 A.F.F. TO BOTTOM AND (2) 2 C. TO TR ROOM DESIGNATED BY ZONES ON "T -100' SERIES DRAWINGS THIS FLOOR. OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. VERIFY EXACT LOCATION WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE DUPLEX RECEPTACLE FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. 8 f RECEPTACLE MOUNTED HORIZONTALLY, ABOVE FINISHED COUNTER TOP. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL AND INTERIORS DRAWINGS PRIOR TO ROUGH —IN. g� PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE CONTROL CONNECTION TO ASSOCIATED HVAC UNIT. REFER TO MECHANICAL PLANS FOR CONTROL WIRING CONNECTION. \% PROVIDE JUNCTION BOX AND 120V CONNECTION FOR RANGE EXHAUST HOOD. VERIFY MOUNTING HEIGHT WITH EXHAUST HOOD SUPPLIER PRIOR TO ROUGH —IN. PROVIDE CARBON MONOXIDE DETECTOR AND BACK BOX ON WALL AT +48 A.F.F. REFER TO FIRE ALARM PLANS FOR EXACT LOCATION AND CONNECTION REQUIREMENTS PRIOR TO ROUGH —IN. PROVIDE CONDUIT AS REQUIRED ON FIRE ALARM DRAWINGS AND CONNECTION TO BUILDING FRCP FOR TROUBLE INDICATION AND UNIT POWER ONLY. INSTALL ELECTRONIC TIMER SWITCH IN —LINE WITH FIREPLACE IGNITION FURNISHED BY FIREPLACE MANUFACTURER. TIME RANGE SHALL BE 0 -180 MINUTES FOR LIVING ROOM FIREPLACE AND 0 -60 MINUTES FOR BEDROOM FIREPLACES. VERIFY MOUNTING HEIGHT WITH INTERIORS DRAWINGS PRIOR TO ROUGH —IN. PROVIDE FLUSH JUNCTION BOX AND 120V CONNECTION TO LIGHTED MIRROR. VERIFY EXACT LOCATION WITH INTERIORS DRAWNGS PRIOR TO ROUGH —IN. ,> PROVIDE MOTOR RATED DISCONNECT SWITCH FOR LAUNDRY EXHAUST FAN. VERIFY LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGH —IN. <;,> PROVIDE 'DOOR JAMB SWITCH FOR CLOSET LIGHTING. LUMINAIRE SHALL BE - ON - WHEN DOOR IS OPEN AND "OFF' WHEN DOOR IS CLOSED. <g> CEILING MOUNTED LUMINAIRE FURNISHED WITH FF &E PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE HALF— SWITCHED DUPLEX RECEPTACLE. \% PROVIDE JUNCTION BOX FOR CONNECTION OF JET (JACUZZI) TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH —IN AND MAKE ADJUSTMENTS AS NECESSARY. < g> PROVIDE 'MASTER SWITCH FOR CONTROL OF GUEST ROOM LIGHTING AND SWITCHED RECEPTACLES (EXCLUDING BATHROOM AND BALCONY LIGHTING. REFER TO WIRING DIAGRAM, THIS SHEET. 200 A 200 A TYPE: MTG.: FLUSH NEW MAIN CIRCUIT BREAKER VOLTAGE 120 1 240 BUS PHASE 1 PH WIRE 4 W 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) V PANEL 4E Panel Notes: 1. PROVIDE GFCI CIRCUIT BREAKER. 2. PROVIDE ARC FAULT TYPE CIRCUIT BREAKER PER NEC 210.12(8), NOTE DESCRIPTION LTG RECEPT MOTORS OTHER TOTAL BREAKER CCT PH CCT BREAKER TOTAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE AMP I P AMP / P REC - L.O. BATHROOM 0 20 / 1 1 A 2 20 1 1 0 REC - KITCHEN L.O. BATH LTG 0 20 1 1 3 B 4 20 1 1 0 DISPOSAL 2 REC - L.O. BEDROOM 0 20 1 1 5 A 6 20 1 1 0 DISHWASHER 2 LTG - L.O. BEDROOM 0 20 1 1 7 B 8 501 0 RANGE 2 RECILTG - BEDROOM 0 20 1 1 9 A 10 / 2 0 " REC -BATHROOM 0 20 1 1 11 B 12 20 / 1 0 IRANGE HOOD REG - MASTER BATHRM 0 20 / 1 13 A 14 20 1 1 0 REFRIGERATOR 1 MASTER BATH LTGIMATS 0 20 / 1 1S B 16 301 0 DRYER 2 REC/LTG - MASTER BED 0 20 1 1 17 A 18 1 2 0 " STEAM SHOWER 0 30 1 19 B 20 20 1 1 0 WASHER " 0 1 2 21 A 22 2011 0 MICROWAVE 1 WHIRLPOOL TUB 0 20 1 23 B 24 20 1 1 0 LTG - GENERAUDRY FAN 0 1 2 25 A 26 2011 01 REC - GENERAL SPARE 0 20 / 1 27 B 28 20 1 1 0 REC- GENERAL SPACE 0 1 29 A 30 2011 0 REC - GENERAL SPACE 0 1 31 B 32 20 / 1 0 RTG- GENERAL SPACE 0 / 33 A 34 2011 0 SPARE SPACE 0 1 35 B 36 2011 0 SPARE SPACE 0 1 37 A 38 1 0 SPACE SPACE 0 1 39 B 40 1 0 SPACE SPACE 0 i 41 A 42 1 01 SPACE PANEL LOADING SUMMARY Refer to Drawing E for bad summary based on NEC 220 (B) GENERAL NOTES: PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL BREAKER ACCESSORIES t = GFCI "= SHUNT TRIP NO NEW LOAD ADDED TO THIS UNIT'S LOAD CENTER. PANELBOARD SCHEDULE SHOWN FOR INFORMATION ONLY. REFER T O TYPICAL LOAD CALCULATIO SHEET E 600 . 4 , ISSUE UNDER B ASE BUIL DING • 'i DO CUMENTS. A P9994 REV PLAN 2006 ISSUE REVISION DATE 111 PR 0094BC 03.03.06 1 130 PR 0094BC -R1 03.17.06 nojwr PROJECT KEYPIAN GENERAL NOTES: 1. PROVIDE RECEPTACLE OUTLETS SPACED PER NEC 210 -52. 2. BACK TO BACK RECEPTACLES SHALL NOT BE ALLOWED. RECEPTACLES SHALL BE SEPARATED BY ONE STUD MINIMUM. REFER TO DETAIL ON E- 500.6. 3. REFER TO (LOW VOLTAGE SYSTEM) DRAWINGS FOR CONDUIT ROUGH -IN FOR LOW VOLTAGE SYSTEMS IN ALL HOTEL AND CONDO LOCK -OFF ROOMS. 4. PROVIDE ARC INTERRUPTING CIRCUITS IN ALL BEDROOMS PER NEC 210.12(8). 5. REFER TO INTERIOR DESIGN DRAWINGS FOR EXACT LOCATIONS AND TYPES OF ALL CONDO UNIT LIGHT FIXTURES AND LOCATIONS OF ALL FURNITURE. 6. REFEER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL CONDO UNIT MECHANICAL EQUIPMENT AND ADJUST LOCATIONS OF ELECTRICAL CONNECTIONS AS NECESSARY. 7. PROVIDE SWITCH ON WALL ADJACENT TO RESTROOM LIGHT SWITCHES) FOR CONTROL OF RESTROOM EXHAUST FAN IN ALL CONDO UNIT RESTROOMS. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR ALL EXHAUST FANS. 8. PROVIDE MOTOR RATED DISCONNECT SWITCH AS NECESSARY FOR LAUNDRY CLOSET EXHAUST FANS. VERIFY REQUIREMENTS WITH MECHANICAL DRAWINGS. DETAIL NOTES THIS SHEET: NOTE: NOT ALL NOTES MAY BE USED ON EACH SHEET PROVIDE JUNCTION BOX FOR 120V CONNECTION TO ELECTRIC FLOOR MAT IN CONCRETE SLAB (HATCHED AREA). FLUSH DUPLEX FLOOR RECEPTACLE. 3 GAS FIREPLACE IGNITION. ELECTRIC SNOWMELT. REFER TO TYPICAL INSTALLATION 4� DETAIL ON E- . `\> PROVIDE MEDIA CENTER AND (2) 1" C. TO OF ROOM THIS FLOOR. `v OWNER PROVIDED, CONTRACTOR INSTALLED LUMINAIRE. CONFIRM EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. NOT USED. RECEPTACLE MOUNTED HORIZONTALLY, 6" BELOW FINISHED COUNTER TOP. <� NOT USED. <V 120V CONNECTION FOR RANGE EXHAUST HOOD. CONFIRM MOUNTING HEIGHT PRIOR TO ROUGH -IN. <� MOUNT CARBON MONOXIDE DETECTOR ON WALL AT 18" A.F.F. PROVIDE CONNECTION TO BUILDING FACP FOR TROUBLE INDICATION AND UNIT POWER ONLY. `� SWITCH FOR INDIVIDUAL CONTROL OF FIREPLACE BLOWER RECEPTACLE <a FLUSH JUNCTION BOX FOR 120V CONNECTION TO LIGHTED MIRROR. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <� HALF SWITCHED RECEPTACLE. <a> CEILING MOUNTED JUNCTION BOX FOR POWER CONNECTION TO MOTORIZED DRAPERIES. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE (1) 1/2' C WITH PULLSTRING FOR POWER AND (1) 1/2' C FOR CONTROLS BACK TO MEDIA CENTER LOCATION. <a> FLUSH JUNCTION BOX FOR 120V CONNECTION TO FLAT SCREEN T.V. CONFIRM LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. <a> PROVIDE JUNCTION BOX FOR 120V CONNECTION TO THERMOSTAT. PROVIDE JUNCTION BOX FOR 120V CONNECTION TO WHIRLPOOL TUB. VERIFY CONNECTION REQUIREMENTS WITH TUB MANUFACTURER PRIOR TO ROUGH -IN. \ ��111 U 1111 U r1 /// REG /s' %,,� 1 �� `CC Fflt,.� r • Ott -: i s• , OWNER/DEVELOPER VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO ARCHITECT OF RECORD Denver, Colorado MASTER PLANNER & DESIGN ARCHITECT HART HOWERTON NEW YORK, NEW YORK STRUCTURAL ENGIN MONROE & NEWELL ENGINEERS, INC AVON,COLORADO MEP ENGINEERS CATOR, RUMA AND ASSOCIATES, CO. DENVER, COLORADO CIVIL ENGINEER ALPINE ENGINEERING, INC. VAIL, COLORADO INTERIOR DESIGN SLIFER DESIGNS EDWARDS, COLORADO PROJECT NUMBER: 20826.01 ISSUE REVISION DATE 002 DD FROG 1 04.12.04 003 DD PROG 2 05.21.04 004 PRICING PKG 06.21.04 005 CD PROG SET 01.14.05 006 PERMIT /BID 02.15.05 PRO)acr N PROJECT KEYPLAN ENLARGED CONDO F P: \PROJECTS \2003 \2043 -237 VAIL LIONSHEAD CORE REDEVELOPMENT \CAD \DDS \EIEC \P- QELEC4- C -F.DWG - E474 PLOT: 02/10/2005 @ 1:51pm REV: 02/10/2005 USER: Ira II E474 4TH FLOOR ENLARGED CONDO F (484) LOWER LEVEL PLAN b SCALE: 1 /4" =1' -0"