Loading...
HomeMy WebLinkAboutB08-0363NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 7OWNOFVAII? Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT MF BUILD PERMIT Permit #: B08-0363 Project #: PRJ08-0582 Job Address: 413 GORE CREEK DR VAIL Location......: SUITE 4 Parcel No....: 210108233005 OWNER BAILEY, JEFFREY M. - KEMMET, 10/10/2008 1735 VIEW POINT RD BOULDER CO 80305 APPLICANT BROWN-WOLIN CONSTRUCTION 10/10/2008 Phone: 970-949-4186 P.O. BOX 701 VAIL CO 81658 License: 100-A CONTRACTOR BROWN-WOLIN CONSTRUCTION 10/10/2008 Phone: 970-949-4186 P.O. BOX 701 VAIL CO 81658 License: 100-A Description: INTERIOR REMODEL Status .. : ISSUED Applied . . : 10/10/2008 Issued...: 10/3012008 Expires...: 04/28/2009 ,"OA L. vG Occupancy: R2 Valuation: $75,000.00 Type Construction:VA Total Sq Ft Added: 0 ##*#***#*##*###_______###„###*#************#***##*#**#**##*********#***###**#*#* FEE SUMMARY •##***####****#******# .***#*************#*****#*#*##*###******** Building Permit Fee------ > $818.75 Will Cal Fee--------------------- > $4.00 Total Calculated Fees ------------- > $2,654.94 Plan Check--------------------> $532.19 Use Tax Fee--------------------- > $1,300.00 Additional Fees ---------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--------------> $2,654.94 Investigation-----------------> $0.00 Recreation Fee > $0.00 Payments--- -----------------> $2,654.94 Total Calculated Fees--------> $2,654.94 BALANCE DUE------------------------ > $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHA L BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM (V?0/0 bld _alt_construction_perm it_041908 8:00 AM - 4:00 7.?/J/Ac &ZI- w Signature of Owner or Contractor Date t24ad 6rN?. ?J NtGv- Print Name APPROVALS Permit #: B08-0363 as of 10-30-2008 Status: ISSUED Item: 05100 BUILDING DEPARTMENT 10/10/2008 JLE Action: CR APPLICATION INCOMPLETE, NO PLANS SUBMITTED. CALLED APPLICANT. 10/29/2008 JRM Action: AP Item: 05400 PLANNING DEPARTMENT 10/15/2008 Warren Action: NA All changes are internal and do not affect GRFA. Item: 05600 FIRE DEPARTMENT See the Conditions section of this Document for any that may apply. b Id_a It_co n st ru ct i o n_pe rm it_041908 CONDITIONS OF APPROVAL Permit #: B08-0363 as of 10-30-2008 Status: ISSUED Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 40 (BLDG): (MFR/COMM) FIRE ALARM REQUIRED PER NFPA 72. b Id_a It_co n st ru cti o n_pe rm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080002078 Amount: $2,654.94 10/30/200808:32 AM Payment Method: Check Init: DDG Notation: Brown-Wolin 6718 ----------------------------------------------------------------------------- Permit No: B08-0363 Type: ADD/ALT MF BUILD PERMIT Parcel No: 2101-082-3300-5 Site Address: 413 GORE CREEK DR VAIL Location: SUITE 4 Total Fees: $2,654.94 This Payment: $2,654.94 Total ALL Pmts: $2,654.94 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 818.75 PF 00100003112300 PLAN CHECK FEES 532.19 UT 11000003106000 USE TAX 4% 1,300.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Date: 10/10/2008 Time: 01:19 pro Page: 1 of 9 CITY L Town of Vail ' Phone 110317639639 e(Z H E RR E of py I°ax 1 103;, 763 9686 E-Mail Lennie.Herron; Dcomcast.net Hazardous Materlals*Mold*Asbestos*Lead Paint Website www.HERROtI-En erprises.com Environmental Services*lndustriai Hvaienists 7261 W. Hampden Ave.. Lakewood. Colorad r 80227-5305 October 10, 2008 To: Brown-`Volin Construction, Inc./Mr. Rich Brown HERRON® Project No.: 1001081 Job No.: Verbal Location: `Single Family Dwelling', 413 Gore Creek, Vail, CO Date(s) of Service: October (13-06, 2008 Services Requested: Environmental Consultation/Limited Asbestos Building Inspection Scope of Work Per your request, and under the guidelines defined, HERRON* Enterprises USA, Inc. (HERRON*) hay co ii,b ided the Environmental Consultation/Limited Asbestos Building Inspection at the aforementioned property. Local, state and/or federal regulations, including but not limited to the Air Quality Control Division (AQCC) 1. ,-;ulation 8, OSHA 1926.1101, and EPA (NESHAP) 40 CFR Part 61 may require a comprehensive asbestos inspeGtiol prior to a renovation or demolition. This inspection requires an AHERA and State certified asbestos building inspector id tfifying and sampling any friable and non-friable asbestos containing materials which could be affected by the activity. HERRON* was contracted by the Client, to perform: a Environmental Consultation/Asbestos Services, Limited Asbestos Building Inspection, specifically tailorc d to Friable and Non-Friable Suspect Asbestos Containing Materials (ACM), associated with the aforement one 3 property, specifically; Client directed Limited Asbestos Building Inspection prior to a renovation of `Single Family Dwelling', 4 [3 1 or a Creek, Vail, CO as follows: White Drywall Walls/Ceilings throughout Attic Non-Destructive bulk sampling; Rush turnaround PLM Analyses; It was expressly advised that although this is a Limited Asbestos Building Inspection, it is comer-,hen s vz to the aforementioned materials. Only materials impacted requiring response actions have been instructed and it therized by the Client. Under the protocol of limited sampling whereas not `all' suspect materials outside of the response a;,ion areas were sampled, under local, state and/or federal regulations, including but not limited to WAQS&k2 R.elu -ation and OSHA 29 CFR 1926. 1101, a certain protocol for sampling, number of samples obtained, and assessment I's r,-.: lul'i ed. HERRON* was subsequently contracted by the Client, to perform: Rush turnaround PLM Point Count Analyses. HERRON" Project No. 1001081 Page No. - 1 ct * r 10, 2008 Limited Asbestos Building Inspection BUILDING PERMIT APPLICATION਍ഀ Separate Permits are required for electrical, plumbing, mechanical, fireplace, etc਍ഀ Project Address lit rt rT7 1 i Ali Plall 65 C,਍ഀ t! I ~ 6 ey-c, C ie "D~ a , it,'( v, Aal਍ഀ Contractor Information਍ഀ Company: G 0 WIYV - 9nJ ti i cw ~Ow l vti਍ഀ Company Ad~dyress: ~ r 0, 7 v x 701਍ഀ oY i਍ഀ City: V ~ State: Ctl Zip: 4 • ~lESi਍ഀ Contact Name: ' ~''`7 w਍ഀ Contact Ph: `)i196 Cell: 31 7a-਍ഀ E-Mail:਍ഀ Town of Vail ntractor ~jegistration No: 100 -A਍ഀ X ,਍ഀ Contractor Signature (required)਍ഀ Property Information਍ഀ Parcel Q 10 J 0 0 a "53 0o l਍ഀ Legal Description: Lot # ~ Blk #਍ഀ Subdivision: y`a i 'Fir. i (5 G Aa t4"਍ഀ Job Name: N I Q, V V a M,44 0_1" e V7 ,bra i) 0 C.਍ഀ Owner Name: Te-4- 3-, 1tv 4 Lo r', V e, mmeft਍ഀ Mailing Address: i y5 i;~z w(~~ wf r\~Ivu~rw' Cap ~a Dui਍ഀ (For Parcel # Contact Eagle Cou ty assessors Office at,970-328-8640 or਍ഀ visit www.eaglecounty.us/patie)਍ഀ Valuations (Labor & Material)਍ഀ -70 l10 U CC਍ഀ Building $ /਍ഀ Plumbing $ ryrK UOC1, 0਍ഀ Electrical $ 2, 000 .0o਍ഀ Mechanical $਍ഀ Total $ `75ooo, oo਍ഀ Project #਍ഀ DRB#਍ഀ Building Permit਍ഀ rr`V 71 `_j J7 r%c l lQ, . /-C 1 7....਍ഀ Detailed D cription of Work: ~ho~+mv14਍ഀ i' fi+•trvk਍ഀ 'tt ~t I~c;iYlC / r~llcrrtCtS t ~loarCOUf✓Ylnf r ~ir5 Cte਍ഀ L, A h ~A/u; 5 , V'u l0 col, aAc %a dSV ~ro~v. Acs਍ഀ /~1 n G~dS~t i^e{~Ct~wfrn /ae.e. VAX I cal6"Wtl਍ഀ MG C fi (n. 5 hJ t'U 1 l v.y~COelc ~kl( ~.C. tA Wd 1਍ഀ (Use additional heet if necessary) *)-61 S' 5 f"_਍ഀ Architect( ) Designer( ) Engineer( ) NA_਍ഀ Phone:਍ഀ Fax:਍ഀ E-Mail:਍ഀ Work Class:਍ഀ New ( ) Addition ( ) Remodel X) Repair ( ) Other ( )਍ഀ Work Type:਍ഀ Interior (y) Exterior( Both O਍ഀ Building Type:਍ഀ Single-Family ( ) Two-Family ( ) Multi-Family਍ഀ Commercial ( ) Townhome ( ) Other ( )਍ഀ # & Type of Existing Fireplaces: Gas Appliances (X)਍ഀ Gas Log ( ) Wood/Pellet ( ) Wood Burning ( )਍ഀ # & Type of Proposed Fireplaces: Gas Appliances ( )਍ഀ Gas Log ( ) Wood/Pellet ( ) Wood Burning ( )਍ഀ Does a Fire Alarm Exist Yes ( ) No(਍ഀ )਍ഀ Monitored Alarm: Yes ( ) No V)਍ഀ Does a Fire Sprinkler System Exist: Yes ( ) No k( )਍ഀ Date Received਍ഀ J~ ~`U%~ I-E਍ഀ Og is ~ j਍ഀ TOWN਍ഀ 141..&਍ഀ A"d਍ഀ tay਍ഀ Date: 10/10/2008 Time: 01:19 Pm Page: 2 of 9 Fax 1103) 763 9639 ERA x H E RRO N® Phone 86 Enterprises USA, Inc. ()03; 763 9686 E-Mail Lennie.He:rori{?comcast.net &hod ? Hazardous Materlals*Mold*Asbestos*Lsad Paint Webslte www.HERRON-En erprises.com Environmental Serviceeindustrial Hvalenists 7261 W. Hamoden Ave.. Lakewood. Colorad ) 80227-5305 Assumptions, and Limitations This Environmental Consultation/I-imited Asbestos Building Inspection is applicable in whole, not in part, 1) the entire contents of the document. HERRONe and this Environmental Consultation/Limited Asbestos Building Inspection make no repme eithtion or assumptions as to past and/or future conditions/occurrences of the spezific area(s) inspected. The results, conclu.'.ions and/or recommendations expressed in this Environmental Consultation/Limited Asbestos Building Inspection are based 4 0l dy on the conditions which were observed at the time of this Environmental Coniultation/Limited Asbestos Building Inspection. HERRON®'s inspection incorporated non-destructive sampling techniques and visual inspections in areas vliich were visible/accessible. Conditions and/or materials which were not inspected and/or commented on may very well differ from those which were inspected and/or commented on. Closure This report is provided for the use of the Client as it applies to the subject property. Its preparation has been in a c:;ordance with generally accepted practices in asbestos, and industrial hygiene. Thank you for the opportunity to be of service. Should you have any questions or comments regarding this repo 1, please do not hesitate to call HERRON" Enterprises USA, Inc. Sincerely, Billie J. Hw...,.:-Lusk Project Manager HERRON® Enterprises USA, Inc. Certified Asbestos Building Inspectors(s): Billie J. Herron-Lusk (Project Manager), and Robert A. Longmire HERRON® Project No. 1001081 Limited Asbestos Building Inspection Recommendations Page No. - 2 c ct,*.r 10.2008 Date: 10/10/2008 Time. 01:19 pro Page: 3 of 9 ERA HERRON" Enterprises USA, Inc. &hodHazardous Materials*Mold*Asbestos*Lead Paint Environmental Services*lndustrial Hvaienists The Client has advised that the project is a renovation. Phone { 3031 763 9639 Fax { 303; 763 9686 E-Mail Lennie. Herron( Dcomcast.net Website www.HERROPI-En erprtses.com 7261 W. Hampden Ave.. Lakewood. Cotorad ) 80227-5305 As the Drywall/Joint Compound Material is classified as a Category II non-friable ACM, then the ma te17 ,: l would be exempted from AQCC Regulation 8, if the material is not made friable during the renovation or demolitions. At a minimum, this material should be removed by trained personnel in accordance with 29 CFR 1926.1101 (CSS] L 1 i Class II Activities. The OSHA trained personnel should perform, at a minimum, an initial exposure assessment. HERRON* would recommend as a minimum Plan of Action: 1. Asbestos Abatement Summary of Work: coordinated with Owner should be developed in order to d rcct proper removal and disposal of Drywall/Joint Compound Materials would include 29 CFR 1926.1101 (OSFI.A ). If the Drywall/Joint Compound Material, which is Non-Friable, is in Good Condition (at time of the inspection) is removed in a wet, non-friable manner as a Class II Activity, then it is recommended that the material may be rcmovi, t by OSHA trained personnel and disposed of as `clean demolition'. 2. Asbestos Abatement (to facilitate renovation or demolition): coordinated with Client, should the matcria.l be required to be removed prior to a renovation or demolition activity. and/or 3. Asbestos Air Monitoring: Asbestos Air Monitoring of project on behalf of Client, i.e., compliance to local, state, and/or federal regulations, including but not limited to OSHA 1926.110 1, i.e., baseline air monitoring, pri -abatement visual containment inspection(s), removal air monitoring, OSHA. Compliance air monitoring, final visual ? entainment inspection(s), final clearance air monitoring, etc. HERRON® Project No. 1001081 Page No. - 3 ( clot -r 10, 2008 Limited Asbestos Building Inspection Date: 10/10/2008 Time: 01:19 pm Page: 4 of 9 ERA HERRQNO Enterprises USA, Inc. Hazardous Mlaterials*Mold*Asbestos*Lead Paint Environmental Services*lndustrial Hvoienists CuncCnsion Phone ( 1031 763 9639 Fax 1103) 763 9686 E-Mail Lennie. Herron( Dcomcast.net Website www.HERROIJ-En erprises.com 7261 W. Hamoden Ave., Lakewood, Colorad ) 8:1227-5305 Based on the information generated by this report, we conclude that the aforementioned property does haw 'Rc!gulated Asbestos Containing Material(s) (R.AChI) in accordance with local, state, and/or federal regulations for p ti-poses of a renovation or demolition (when conducted in accordance with local, state and/or federal regulations). Sample No. 100308-1 A 100308-I B 100308-1 C Homogeneous Material Description White Drywall/Joint Compound (Class II) Walls, Miscellaneous Materials (M), Non- Friable, Goed Condition (Current Condition), throughout Attic N Wall, 2' from Floor, 1' from E Wall, Sample 1 of 3 W Wall, 2' from Floor, 1' from N Wall, Sample 2 of 3 Ceiling, SE Corner, Sample 3 of 3 Approxi- mate Quantity' 'SF AHERA Asbestos Laye r? Rating2 Laboratory Physical Die cjription Results 0.0% 0.0% <1.0% C <1.0% C (point count) 0.0% 0.0% 0.0% 0.0% 4.0% C 2.0% C (point count) A: Whito plas ): r w/goldlwh to p dat B: Tan/white d: yw 111 w/white paint A: Whito Faint N Iv, hite plaster B: Tan/vihito rl, yw:dl A: White tape B: Gold/wl Cite 1-a .n: C: Tan/v&te (1, ywall D: Whito, plas r 'Quantification not within the scope of this inspection. ZAHERA Rating based on current usage, however, is like y to change dependent on the use of the property. Materials that contain <=1.0% Asbestos are not considered Asbestos Containing Materials by NESHAPSi or E )A but may still be covered by OSHA. OSHA regulations may apply during potential disturbance activities. Although a material may have been determined to contain <-1.0% Asbestos, or during a demolition, if the car tpo 3ition of drywall/joint compound (when the joint compound does not cover the entire surface) has been determined to ,oul ain 1.0% Asbestos, this document serves as a Hazard Communication and should be followed during an activity such as, renovation or demolition, to ensure that an exposure does not occur. The Maximum Allowable Asbestos Level (MARL) ntay not be exceeded at `any' time in accordance with local, state, and/or federal regulations, including but not limite- l tc AQCC Regulation 8 (State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61 EPA (N-E, SIIAP), and 40 CPR 763 EPA (<' I1T, 'A). Suspect materials which were sampled and determined to contain <=1.000 Asbestos (refer to Attachments), by 'l:,M and/or PLM Point Count analysis are: None detected. HERRON® Project No. 1001081 Page No. - 4 ( clot` .r 10, 2008 Limited Asbestos Building Inspection Date: 10/10/2008 Time: 01:19 pm Page: 5 of 9 ec(iZ ® Phone ( )031763 9639 H ERRON Enterprises USA, Inc. Fax i iua; 763 9686 E-Mail Lennie. He:ron(D:omcast.net Hazardous Materlals*Mold*Asbestos*Lead Paint Website www.HERROIJ-Erg erprises.com Environmental Services*Industrial Hvaienists 7261 W. Hampden Ave., Lakewood, Colarad ) 80227-5305 Suspect materials which were not within the Scope of Work at the time. of the inspection were: 1. `All' EPA suspect Materials not requested. 2. `Any' confirmed or suspect ACM which may have been concealed at the time of the inspection 3. During a normal inspection, and more specifically when non-destructive sampling techniques are cmpflcn a d. it is not within the scope of the inspection to remove surface materials to inspect the structures and/or materi.al?; w.l ii;h. may be under the surface, i.e., within or under concealed areas such as under carpet, under sub-floors, within cl ases, walls, crawlspaces, tunnels, etc., to remove suspect Asbestos Containing Material(s), to move and/or sample rlec ri:,al wiring which has not been 'locked out', etc. All said areas are to be assumed as containing >1.0% Asbestos, until such a time that these areas are made accessible, and/or rendered safe so that sampling can be performed. 4. IIERRON", recommends extreme caution during a renovation o1 lemolidun of these areas in the t11ai all area which was not suspect, visible, accessible and/or specified during the inspection, is discovered to contair or s suspected of containing an Asbestos Containing Material (ACM). Under local, state and/or federal regulations, sho ald such an event occur, the Client and or Contractor is required to cease operations which may effect this (these) rnateri; l(s) until an inspection is concluded and a determination is made by an AHERA and State Certified Asbestos Building Ins r: cror. 5. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is compreh,e 1sive to the af,,.QI,.entioned materials. Only materials impacted requiring response actions have been instructed and al tl iorized by the Client. Under the protocol of limited sampling whereas not `all' suspect materials outside of the responso a;,t:ion areas were sampled, under local, state and/or federal regulations, includi°Ig but not limited to WAQS&R R.et. u',a tion and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained, and assessment is r-, luired. 6. Disturbance of these areas could create a potential health haz?xd Suspect materials which were visually inspected and determined to be NOn•ACM materials at the time of the insp c tion were: None detected. HERRON® Project No. 1001081 Page No. - 5 ( ct A er 10, 2008 Limited Asbestos Building Inspection Date: 10/10/2008 Time: 01:19 pm Page: 7 of 9 RE1 LAB Reservoirs E" 'w October 6, 2008 Lennie Herron Herron Enterprises, USA, Inc. 7261 W. Hampden Ave. Lakewood CO 80227 Dear Customer, Laboratory Code: Subcontract Number: Laboratory Report: Project Description: RES NA RES 162227-1 1001081 None Given 1ilf 7C_ Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial H; g ene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVL.AP , Lab Code # 101896 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy F'L\A) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Geri: flcz:te #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient it both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as pE'.l ycur request. The analysis has been completed in general accordance with the appropriate methodolc g,/ as stated in the attached analysis table. The results have been submitted to your office. RES 162227-1 is the job number assigned to this study. This report is considered highly confident al and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of thin study with personnel other than those of the client. The results described in this report only apply to the sa Tip!es analyzed. This report must not be used to claim endorsement of products or analytical results b,/ IJVL AP or any agency of the U.S. Government. This report shall not be reproduced except in full, without e it ttan approval from Reservoirs Environmental; Inc. Samples will be disposed of after sixty days unless I Dnc)er storage is requested. If you have any questions about this re port, please feel free to call 303-964-19'. 5. Sincerely, Jeanne Spencer Orr President Analyst(s): Paul D. LoScalzo Wenlong Liu Paul F. Knappe Rich Wegrzyn Michael Scales Adam Humphreys Nancy R. Adams Scott Klaus P: 303-964-1986 5801 Logan Street, Suite 100 Denver, CO 80216 1-8(36-F E:SI-ENV F: 303-477-4275 bANm.r Wah com Page 1 of 2 Time: 01:19 Om Page: 8 of 9 Date: 10i10?2008 • uo •• C)O 0 0) LO O C ° Q ?. O ? D N .F ? d E O U O is N LO p O O p N Lr) p 0) 43 o 0 7 °o CIO 0 m c 3 : -0 1 •- o (D LL fl c 16 ? A" ZZ Z b N j3 C3 Cl ZZZ w m v o. E N ?. W w fi O U O u en ... w Z? fi c V a ? o U OL t o o O 00 0 d V Z Q ? tv7 C d R Z m ? C ? N O 9 O V 1 G d CL ZM c Z at ° 3 m OC O c m m ? •= '= c somas a ? g w < Q m 4co ?¢rw O ? U w ? ao a ? N D D { C d C N ?- ?y 2 E T OD ap r Z N W ?- L W ? app(' ?fn ?? Cl) ? th ? Z OC Z W ? W u ea OaNO a W=r W a Z t1 J O Q Z Q a 4 - n > C V/ L Z O Ay Y E V V W 0 N d 7 N N [] Q T m T r ° `n ° ^ d ° W q.. a rn m Q = ac o ?. U) c M O N i cv c O J C O W G N .. C a Q ?UUU?Q?- Ll t17Z `r H Date: 10/10/2008 Time: 01:19 pm Page: 9 of 9 N I N b T? in. Ll I D_ O ??vP C) ? f5 IL 4 H i z v 1 1.) Fk ! W ? E 3 91 ixl It II tl R Im E U 1 t7 0 st G' w m aM L4 ? ®1 ti ,}?> ' jQ Ij A C c e +' : rr : ? I s 'oS = . ru aPoJ ?leW &KW n B-V ! ?' ) atunlOA aldLUBs 4Ye t 6? •W u C+ e< ? a? U 0 s, 3t W G 0 :3 :3 00 Y cry _. ... a3w.o abc 088) O-OZB e.A rMS SOINVONO U4'Iti Stk'321ty altifla ?UICJ18ft/i l' :I f3 t': E']N WaAruy - glNL3w LLI a;rnjidvas, jvj,1 IStl41 ? V1,S'IJ ?I]t?9 VOGDL NYad'. {? -- uer `l+ Q3j 'L5}tr (; gana"t V6--j Yp31 Itin?;lnad j?i?slbu;z'? 'jNX{c`IIY)0lJG?' w Vdld 6 u jr o,= i' Z SL F ?p 0 : -0 CL 40 .? y -fi m G LU -VS 10 ca V .. _ U ?q F Yt M su A R £ :S R a rt m rn v ? f 1 0 ¢ 6 ? m ? t , F , p E I: l ' m a I. , g O 3 r ? . E o G ` t O ? I v nF T S9 ?y G t ( Q Q r 11`St 9 N ro L ? Z ?C IF w C: {G r U y I u a I E w ?` I .. fY m I 4 G7 a I T, z J ? f, li I., I. s' 9) c! Ewingr L'neineerine. inc. P. O. Box 2526, Vail, Colorado 81658 (970) 949 - 5153 phone & fax Town of Vail 0% Ipm am Ll P 01; C Aft UNI- '' ?1'0= L P Brown-Wolin Construction P.O. Box 701 Vail, Colorado 81657 (970) 949-4186 (970) 949-6847fax October 14, 2008 ?Sr -o3L? RE: Bailey Residence Remodel, #4 Vail Trails Chalet, 413 Gore Creek Drive, Vail, Colorado 81657 T.W.I.M.C.. This letter is to confirm that the wall sections that Mr. Brown is planning to replace with a railing are non-load bearing walls. The wall sections involved are located at right angles to each other. They are located on the "creek" side of the unit between the kitchen and a loft closet/storage area. A four foot section of one wall and a six to eight foot section of the adjoining wall are to be removed and replaced with a metal railing. The wall sections that are to be removed are approximately five and one-half feet tall. The railing is to be thirty-six inches tall leaving approximately two and one-half feet of open space above the top of the new rail system and the existing sloped ceiling of the building. If there are any further questions, please feel free to call me. Submitted by: Albert N. Ewing,' Colorado P.E. 1 1 2 s. ? ??:rs• NC ?' O `nF c'C1?o+? Q O r 0 E ti ?... > A 1 ?.1 Ci U) S CI 7 p crr 0 3 r?? 6J1 X 1 'o MBA P x ? -ddft /bo? _.A7JA3 `i f. ?a t? oZir +J W ti ti r et 1 Q C cG ..._-? --?- G..J Y ? M V " fl` .r, O ? Q Cs3' ? V' n ~``? o? lJJ ty ?- P .ors a ? n Co ? W V 0 a oa ? ?rp t- t C' h r NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWNOFVn>i Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0267 . 50y" AMF Job Address: 413 GORE CREEK DR VAIL Location.....: SUITE 4 Parcel No...: 210108233005 OWNER BAILEY, JEFFREY M. - KEMMET, 10/29/2008 1735 VIEW POINT RD Status ... Applied .. Issued . . . Expires. .: PRJ08-0582 ISSUED 10/29/2008 10/30/2008 04/28/2009 BOULDER CO 80305 APPLICANT JOHNNY ELECTRIC 10/29/2008 Phone: 970-376-1463 CELL # P.O. BOX 3968 Avon CO 81620 License: 137-E CONTRACTOR JOHNNY ELECTRIC 10/29/2008 Phone: 970-376-1463 CELL # P.O. BOX 3968 Avon CO 81620 License: 137-E Desciption: ADDING CANS AND SM OKE DETECTORS FOR INTERIOR REMODEL Valuation: $3,500.00 Square feet: 800 FEE SUMMARY *«*„«*«*«**«*«*««*....*..,.*.....«*.**.**«.**«*«*,.,.,?...*..*.**.«* Electrical Permit Fee--------- > $51.75 Total Calculated Fees--> $55.75 Investigation Fee--------------> $0.00 Additional Fees ---------- > $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee------------------- > $0.00 TOTAL PERMIT FEE---> $55.75 Total Calculated Fees ------- > $55.75 Payments-----------------> $55.75 BALANCE DUE---------- > $0.00 APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 10/29/2008 JGG Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. It)— 30 -03 S' ature of Owner or Contractor Date n?`2 2 C' "K0 h S Print Name Project #: elec_prm_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080002080 Amount: $55.75 10/30/200810:20 AM Payment Method: Check Init: DDG Notation: Johnny Electric 4367 Permit No: E08-0267 Type: ELECTRICAL PERMIT Parcel No: 2101-082-3300-5 Site Address: 413 GORE CREEK DR VAIL Location: SUITE 4 Total Fees: $55.75 This Payment: $55.75 Total ALL Pmts: $55.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 51.75 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 'I0 wN OVIAdg?` Development Review Coordinator 75 South Frontage Road Vail, CO, 81657 Phone: 970-479-2128- Fax: 970-479-2172 Inspections: 970-479-2149 ELECTRICAL PERMIT APPLICATION Project Address IOG l rQ < <5 (f l a (S t',(k r 7 i X113 G?*e.C'ree4 ?r?vc? jfa?l (rclla5? Contractor Information Company: . lahh ?j?? Sri C, l ?L?. Company Address: Pe --7, 10/ if City: State: Co Zip: ! G Contact Name: ?T-Qj i"k,,il crO.S .51 Contact Ph: Cell: `,''7l E-Mail: 'VCC(2cril?: > GN-L? 7Yl Ater Town of Vail Contractor Registration No: ?9! 7 X Contr or Signature (required) Property Information Parcel #:a) o / o8?;z X3.3 -00,5 Legal Description: Lot # q Blk # Subdivision: Y" -( k ?1a; h` Job Name: I )PL-65?' pielEA4AfEtRF-,Aa L Owner Name: TC4t Da?Z at"i /_e-r`. eC m 171??v/?err?4 /?e'.; a+?(der ?a a Mailing Address: 1075 (For Parcel # Contact Eagle County Issessors Office at 97d-328-8640 or visit www.eaglecounty.us/patie) Architect( ) Designer( ) Engineer( Name: Phone: Fax: E-Mail: Project #: /i'G?lJJ?tl /oZ r Building Permit #: Electrical Permit #: Detailed Description of Work: Add C0_',ci OQ teC1r'?,5 (Use additional sheet if necessary) COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Material) Amount of SQ Ft tJ®d S1 Electrical $ _?SOO ehc> Work Class: New ( ) Addition ( ) Remodel (jn Repair ( ) Other ( ) Building Type: Single-Family ( ) Two-Family ( ) Multi-Family ?Y) Commercial ( ) Townhome ( ) Other ( ) Date Received: DI _ `?I ?`rv ? ? S .. SRS T??J1i OF VAIL- s r NOTE: THIS PERMIT MUST BE POSTED ON JOBSI TE AT MWNO VY Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 ALL TIMES X03 - D SG=s MECHANICAL PERMIT AMF Job Address: 413 GORE CREEK DR VAIL Location.....: SUITE 4 Parcel No...: 210108233005 OWNER BAILEY, JEFFREY M. - KEMMET, 12/08/2008 1735 VIEW POINT RD BOULDER CO 80305 APPLICANT BLACK DIAMOND FIREPLACE LLC 12/08/2008 Phone: (719) 293-0481 PO BOX 7 LEADVILLE COLORADO 80461 License: 410-M CONTRACTOR BLACK DIAMOND FIREPLACE LLC 12/08/2008 Phone: (719) 293-0481 PO BOX 7 LEADVILLE COLORADO 80461 License: 410-M Desciption: INSTALL GAS FIREPLACE Valuation: $1,842.00 Permit #: M08-0312 Project #: PRJ08-0582 Status ...: ISSUED Applied ..: 12/08/2008 Issued. .: 12/1512008 Expires . .: 06/13/2009 ***************rt*****rt*******************#***********************##**# -FEE SUM Mechanical Permit Fee---> $40.00 Will Call ------------ > $4.00 Total Calculated Fees ---> $54.00 Plan Check ------------------- > $10.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $54.00 Total Calculated Fees--> $54.00 Payments-----------------> $54.00 BALANCE DUE--------- > $0.00 ***********#**##***#************#*###***#***********###*#*****************######******#**********##**#*#*********#**#**#**************###**#*#************#**##*#*###*##******#********#* APPROVALS Item: 05100 BUILDING DEPARTMENT 12/08/2008 JLE Action: AP NEED CUT SHEET BEFORE ISSUANCE CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. ***************#i**rtrtrt**************_.......?n...k********************#..._._..?......k*****************rt***rt*************** .k************. .k**********************rt**rt****************** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FO INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM -4PG SignatuOwner or Contractor Date Print Name mechcan ical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080002357 Amount: $54.00 12/15/200812:38 PM Payment Method: Check Init: SAB Notation: 3061 BLACK DIAMOND FIREPLACE ---------------------------------------------------------------- Permit No: M08-0312 Type: MECHANICAL PERMIT ------------- Parcel No: 2101-082-3300-5 Site Address: 413 GORE CREEK DR VAIL Location: SUITE 4 Total Fees: $54.00 This Payment: $54.00 Total ALL Pmts: $54.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ - MP 00100003111100 MECHANICAL PERMIT FEES ----------- 40.00 PF 00100003112300 PLAN CHECK FEES 10.00 WC 00100003112800 WILL CALL INSPECTION FEE ---------------------------------------------------------------- 4.00 ------------- 2000-12-08 11:42 Black Diamond Firepl 719-293-0481 >> nks1 Room ( WSVL*m ?rrr to scab ?Juds: -to Mechanical Room Dimensions Combustion Air Duct Size and Location Flue, Vent and Gas Line Size and Location - Heat Loss Calculations Equipment Cut / Spec Sheets Pro)aot Address %0 aim AAW!ie & ,dc! ConOwA for Inbtmatikm Company: `Mt7v1 .??, C'e ? 1 Company Address: --p• d. . City: Lfadjavlv- Stater Zip: 9&A 6. Contact Name' 'all Contad Ph: Coll: E-11AaIL- r > . Town of ntra r Regi No: 0 amr 8ignatu (required) r . p" irdbrrnadon Parosl # d? l6 LO R- 3 3 5 Leo De*Wptlon: Lot * Blk # Subdivision: Job Name: Owner Nsme: ^M6l0/ M .Rlkf? Mwft.Address: f33s' , , -1 I?.Q &"flw & s'A2 (For 0amel p Corded Fagin County essassors Office at 870-3264640 or vial www.Ngiscounty.ux> *tie) Architect () Designer( ) Engineer( ) Name: Phone: Fax: E-Mall: N Project MPAN ?Q - &Mp Building Permit * A a tg -d3ib-z?. Mechanical Permit M: I -1 N 031 Detslled Descriptlon of Work: I)S{IWI Ram,.,i rva S;aRre`_ (Use additional sheet K . „; saary) Complete Valuation for Mechanical Permit: Mechanical $ i P 111 Work Class: New () Addition ( ) Remodel M Repair ( ) Other ( ) Boller Location: Interior ( ) Exterior ( ) Other ( )? Nolryps Hulstlng FlrWaam., Gas AppliencesXGas Loge ( ) Wood/Pellet ( ) NoR'yps Proposed Fireplsow: Gas Applipnces()d Gas Loge ( ) WoodlPellet ( ) Building Type: Single-Family ( ) Two-Family O Muid-Famlly Commercial( Townhome ( Other( ) Date Received: DEC o 8 2008 TOWN OF VAIL T owW1-4Mj 1AUST be atthed ho this t?nR11t eoollc en NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Too *V Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 PLUMBING PERMIT Permit #: P08-0143 AMF Project #: PRJ08-0582 Job Address: 413 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: SUITE 4 Applied ..: 10/29/2008 Parcel No...: 210108233005 Issued . .. 10/30/2008 Expires . .: 04/28/2009 OWNER BAILEY, JEFFREY M. - KEMMET, 10/29/2008 1735 VIEW POINT RD BOULDER CO 80305 APPLICANT BAIN BROTHERS P & H INC. 10/29/2008 Phone: (970) 625-5550 PO BOX 1924 RIFLE COLORADO 81650 License: 369-P CONTRACTOR BAIN BROTHERS P & H INC. 10/29/2008 Phone: (970) 625-5550 PO BOX 1924 RIFLE COLORADO 81650 License: 369-P Desciption: REPLACE SHOWER CONTROLS AND DRAIN, BATH TUB CONTROLS, KITCHEN SINK & FAUCET Valuation: $2,000.00 *****#. ..... k**#. .k**************************. k*# ............-..****** FEE SUMMARY *********._. ..----- ------ .....************..... k***. **********************? Plumbing Permit Fee---> $30.00 Will Call ----------> $4.00 Total Calculated Fees ---> $71.50 Plan Check ---------------- > $7.50 Use Tax Fee------------ > $0.00 Additional Fees ------------ > $0.00 Investigation ---> $30.00 TOTAL PERMIT FEES--> $71.50 Total Calculated Fees--> $71.50 Payments ------------------- > $71.50 BALANCE DUE > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 10/29/2008 JLE Action: AP #*##########*#**##***#*#####*#*#****##**#####**#****######******#****#*******************************************#*#*#***#**#******#*********#***********************************##****** CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL E MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0t AM -4 PM. 11?6 '4 6 Signature of Owner or Contractor Dark Print Name plmbpermtl_041908 ******************************************************************************************** TOWN OF VAIL, COLORADO Statement Statement Number: R080002077 Amount: $71.50 10/30/200808:30 AM Payment Method: Check Init: DDG Notation: Brown-Wolin 6717 - - - -------- -------------- ------------------- Permit No: ----------------------------- - -- - P08-0143 Type: PLUMBING PERMIT Parcel No: 2101-082-3300-5 Site Address: 413 GORE CREEK DR VAIL Location: SUITE 4 Total Fees: $71.50 This Payment: $71.50 Total ALL Pmts: $71.50 Balance: $0.00 ******************************************************************************* ************* ACCOUNT ITEM LIST: Account Code Description C urrent Pmts ------- ----------------- PF 00100003112300 --- ------------------------------ - PLAN CHECK FEES ---- 7.50 PN 00100003153000 INVESTIGATION FEE (BLDG) 30.00 PP 00100003111100 PLUMBING PERMIT FEES 30.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Development Review Coordinator 75 South Frontage Road Vail, CO 81657 Phone: 970=479-2128 Fax, 970-47972172 m Inspections: 970-479-2149 TOWN OF VAIL PLUMBING PERMIT APPLICATION Project Address: 0A t'-#y? ra+l5 C'Aa)e'13 LJ 1 C?ov e. Cwt;c(,G k?v Its / Vat 1 V1 t1 ? Project #: 'FeWD F;-05$? Building Permit #: z: O ?V?(0 *; Plumbing Permit #: F" () 1 `l Contractor Information..,! Company: &'m 6rvrt ,ev- P4-14 , Z'vtd; Company Address: 1 / 9 City: K z ? l' State: CO zip: 9l -s0 Contact Name: 13a ; VN Contact Ph: 770 A-')'5 ° S 550 Cell: 770-170 ° e131 ?L _BMA; 1-wz6 s e ,II'd.SAj„ GC1!?+t E-Mail: yL Town of Vail Contractor egistration No:? - F X / Ile Contractor Signature (required) Plumbing Valuation (Labor & Material) ?n Plumbing $ Architect () Designer () Engineer ( ) Name: Phone: Fax: E-Mail: Detailed Description of Work:ne-,z )4,1{, ???5flvt? 5 6 d-rt- rls 4 d Pa (y, Is-, (Use additional sheet if necessary) Work Class: New ( ) Addition ( ) Remodel ()4 Repair ( ) Other ( ) Property Information Building Type: Single-Family ( ) Two-Family ( ) Multi-Family 00 Parcel #: o'? 10 10$a 35 00-5 Commercial ( ) Townhome ( ) Other ( ) Legal Description: Lot # U 0 7 Blk # Subdivision: f / a ? i 1 r ? Is ot Date Received: Job Name: .6AJ 9q , if?41 /0IFT 9 Q,Mo -0 Vt- r Owner Name: -v) e-4 B a t (W d- Z a f i V L in kvlt_t LG d Mailing Address: /?;7 5 V, ft,,,P dint (7dZeauev-} 4 s 70 n0 =G I! (For Parcel # Contact Eagle County assessors Office at 970-328-8640 br visit www.eaglecounty.us/patie) w r' TOWN OF:' tql 50 01-05-2009 Inspection Request Reporting Page 6 4:25 Dm Vail, CO - City Of A/P/D Information Requested Inspect Date: Tuesday, January 06, 2009 Inspection Area: JRM Site Address: 413 GORE CREEK DR VAIL SUITE 4 Activity: B08-0363 Type: A-MF Const Type: Occuppa?nc??rr: Owner: BAILEY, JEFFREY M. - KEMMET, LORI -JT Contractor: BROWN-WOLIN CONSTRUCTION Description: INTERIOR ?tEh Reauested Insoecti ln(?) i Item' 9 BLDG-Fi Requests B OWN-WC Comme ts: Ipck box I M Assigned l o: ,1MONDRAG Ac ion: i N CONSTRUCTION Sub Type: AMF Use: VA Phone: 970-949-4186 Time Exp: f ? l ?r r. j `f Requested Time: Phone: Status: ISSUED Insp Area: JRM 01:00 PM 970-949-4186 -or- 376- 1872 Entered By: DGOLDEN K Inspecti on History I j Item: 30 BLDG-Framing Approved 11/04/08 Inspector: GCD Ac ion: NO NOTIFIED Comment: CLURTESY WALK THRU REGARDIN EET METAL DUCTS THAT APPEAR TO BE BATH FANS, KITCHEN EXHUST ETC. FIER OP 2 DUCTS THAT COME THROUGH THE WALL, GUARD AT STORAGE SPACE REQD TO BE 42" THE STORAGE SPACE DOESN'T HAVE HEAD HEIGHT NO ACCESS OR OCCUPANCY ALLOWED. FLOOR JOISTS AND LVL APPR 11/11/08 Inspector: JRM Action: AP APPROVED Comment: 11/14/08 Inspector: GCD Action: AP APPROVED Comment: Item: 50 BLDG-Insulati on Item: 60 BLDG-Sheetrock Nail 11/07/08 Inspector: GCD Action: PI PARTIAL INSPECTION Comment: SHOWER VALVE BACK BOX. Item: 70 BLDG-Misc. Item: 90 BLDG-Final REPT131 Run Id: 8911 P08 -0143 : Entries for Item:290 - PLMB -Final 11:18 01/22/2013 Action Comments By Date Unique_ Key AP Kitchen sink, 2 bath sinks and showers are JGG 12/17/2008 A000121 OK. 101 Total Rows: 1 Page 1 E08 -0267: Entries for Item: 190 - ELEC -Final 11:19 01/22/2013 Action Comments By Date Unique_ Ke AP SHAHN 12/16/2008 A000121 093 Total Rows: 1 Page 1 M08 -0312: Entries for Item-.390 Action Comments AP Gas fireplace was operational Total Rows: 1 - MECH -Final 11:19 01/22/2013 By Date Unique_ Key JGG 12/17/2008 A000121 100 Page 1