HomeMy WebLinkAboutB08-0254NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
TOMOFVAIL
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD/ALT COMM BUILD PERMT
Job Address: 645 N FRONTAGE RD W VAIL
Location......:
Parcel No....: 210106316026
OWNER BUGBY, DALE R. 07/30/2008
645 N FRONTAGE RD W 13-C
VAIL
CO 81657
APPLICANT SAGEBRUSH SERVICES
PO BOX 752
GYPSUM
COLORADO 81637
License: 955-B
CONTRACTOR SAGEBRUSH SERVICES
PO BOX 752
GYPSUM
COLORADO 81637
License: 955-B
07/30/2008 Phone: (970) 524-1031
07/30/2008 Phone: (970) 524-1031
Permit #: B08-0254
Project #: b? -6 31(Y
Status .. : ISSUED
Applied . . : 07/30/2008
Issued...: 08/12/2008
Expires ...: 02/08/2009
Description:
COMMON ELEMENT: WILDLIFE-RESISTANT TRASH ENCLOSURE
Occupancy: U
Type Construction:VB
Valuation: $100,000.00
Total Sq Ft Added: 341
.................................................... .>.._.. ,.................. FEE SUMMARY ............,..,................................._...........................,
Building Permit Fee------ > $993.75 Will Cal Fee---- --------> $4.00 Total Calculated Fees-- > $3,443.69
Plan Check--------------------> $645.94 Use Tax Fee -------------> $1,800.00 Additional Fees------- ---> $0.00
Add'I Plan Check Hours- $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--- $3,443.69
Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00
Payments-- -----------------> $3,443.69
Total Calculated Fees--------> $3,443.69 BALANCE DUE -------------> $0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPEC*nr L BE M DE TWENTY- UR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM - 4:00 PM.
Signature of O tractorD to
Print Name +
bld_alt_construction_perm it_041908
APPROVALS
Permit #: B08-0254 as of 08-12-2008 Status: ISSUED
Item: 05100 BUILDING DEPARTMENT
08/12/2008 Martin Action: AP
Item: 05400 PLANNING DEPARTMENT
07/30/2008 Warren Action: AP
See the Conditions section of this Document for any that may apply.
bld_alt_construction_perm it_041908
CONDITIONS OF APPROVAL
Permit #: B08-0254 as of 08-12-2008 Status: ISSUED
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Entry: 08/12/2008 By: Martin Action: AP
Cond: 34
(BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE
A FOOTING INSPECTION WILL BE CALLED FOR.
bld_alt_construction_perm it_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R080001376 Amount: $3,443.69 08/12/200803:24 PM
Payment Method: Check Init: LC
Notation: #1790/SUN VAIL
CONDOMINIUM ASSOC
-------------------
Permit No: ---------------
B08-0254 ---------------------------
Type: ADD/ALT COMM BUILD ----------------
PERMT
Parcel No: 2101-063-1602-6
Site Address: 645 N FRONTAGE RD W VAIL
Location:
Total Fees: $3,443.69
This Payment: $3,443.69 Total ALL Pmts: $3,443.69
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
---
BP -----------------
00100003111100 ------------------------------
BUILDING PERMIT FEES ------------
993.75
PF 00100003112300 PLAN CHECK FEES 645.94
UT 11000003106000 USE TAX 4% 1,800.00
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
Town of Vail Development Review Coordinator
75 South Frontage Road
13 = n"' Vail, CO 81657
Phone: 970-479-2128
t Fax: 970-479-2172
Inspections: 970-479-2149
T '! VAA1 BUILDING PERMIT APPLICATION
Separate Permits are required for electrical, plumbing, mechanical, fireplace, etc.
Project# Wt U,?, l)?q `7'
Project Address
/ 2 ,? ` ? -17 I e n J DRB# .l l!'4?>0i6 070 1 ? .
Building Permit #: 13A )2,5q
Contractor Information(- /_
Company: 9? K f' k-%- k S S--a %r ?Y .Qr S C
Company Address: / ID d If r k, G i1 S I- (Ft 75.
Cit:-( o, YYl State: Pv Zip: /o 3
Contact Name: A q-, 5 H-LA-?u ?
Contact Ph: 9 70 '5;/y-//n0?31 Cell: Q 710 /3
E-Mail: ?? lr.? ??u.\?ItJ Ip2n"tt?r`i)".?I
Town /Vail ntrac r Registra ' n No:
X OPIO
-.,..?
Con Sig
ne (r wired)
Property Information
Parcel #: 21 V 1 d (0
Legal Description: Lot # 1? Btk # OP
Subdivision: P O`w`?rj P ca'I-C k
Job Name: .Va V'w-J CvC!M?_o `t?c`s 'err
Owner Name: ?Jv?tn 1rCZZQ Ga-SS d L
Mailing Address: ?t 3 5 " i`r P4 V
(For Parcel # Contact Eagle County assessors Office at 970-328-8640 or
visit www.eaglecounty.us/patie)
Valuations (Labor & Material)
Building $
Detailed Description of Work: )o-b c
n_ -J T AA41
(Use additional sheet if necessary)
Architect () Designer () Engineer ( )
Phone:
Fax:
E-Mail:
Work Class:
New ( ) Addition (-./) Remodel ( ) Repair () Other ( )
Work Type:
Interior ( ) Exterior t ) Both 04
Building Type:
Single-Family ( ) Two-Family ( ) Muiti-Family ( )
Commercial( ) Townhome ( ) Other X
# & Type of Existing Fireplaces: Gas Appliances ( )
Gas Log ( ) Wood/Pellet ( ) Wood Burning ( )
# & Type of Proposed Fireplaces: Gas Appliances ( )
Gas Log ( ) Wood/Pellet ( ) Wood Burning ( )
Does a Fire Alarm Exist: Yes ( ) No (
)
Plumbing $ Monitored Alarm: Yes ( ) No(
Electrical $ Does a Fire Sprinkler System Exist: Yes ( ) No ( )
Mechanical $ ? -I ti nn ?/7
Date Received ? ?? `?Z, L I \?!!
Total $ r? I y
,OD 00 0, Vo 1lnj Jul. 2.8 2008
^M_- O TOWN OF VAIL
A;
MiTek"
POWER TO PERFORM.'
Re: 07064-8
Sagebrush / Sun Vail Condo / Enclosure
7777 Greenback Lane
Suite 109
Citrus Heights, CA, 95610
Telephone 916/676-1900
Fax 9161676-1909
Town of Vail
The truss drawing(s) referenced below have been prepared by MO st ym ect upervision
based on the parameters provided by Alpine Truss-Montrose, CO.
Pages or sheets covered by this seal: R29141401 thru 829141402
My license renewal date for the state of Colorado is June 30, 2010.
?lV? J 1/?1 J?
e CZ" (? w
4000
Tingey, Palmer
MiTek Industries, Inc.
August 18,2008
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI-2002 Chapter 2.
t
Job Truss
07064-8 Al
Alpine Truss, Montrose, CO - 81401
-1.4-n I
1A-0
Truss Type Qty Ply Sagebrush / Sun Vail Condo / Enclosure
FINK 16 I 1 ? R29141401
lob Reference (notionan
7 060 s Aug 6 2008 MiTek Industries, Inc. Mon Aug 18 09:29.02 2008 Page 1
s-ze I 1an-n I 14.Q-1n -n-n I o1.e-n
5-26 4-9-1o 4-9-10 5-2-6 1-4-0
5.8 = Scale - 1.42.6
4
fo
6-Q.m
6-9-10
Plate Offsets (X.Y): f2.0-0-2.0-0-51.16:0-0-2.0-0-51.18:0-2-12,0-3-01
LOADING (psf) SPACING 2-0-0
TCLL 80.0 Plates Increase 1.00
(Roof Snow=80.0) Lumber Increase 1.00
TCDL 10.0 Rep Stress Incr NO
BCLL 0.0 Code IRC2006/TP12002
BCDL 10.0
LUMBER
TOP CHORD 2 X 6 SPF-S 165OF 1.5E
BOT CHORD 2 X 4 SPF-S 1650F 1.5E
WEBS 2 X 4 WW Stud
4.6
=
I tv2?
6-4-13
5r6 =
>aan
6-9-10
CSI DEFL in (loc) I/deft L/d PLATES GRIP
TIC 0.42 Vert(LL) -0.11 8-9 >999 360 MT20 169/123
BC 0.63 Vert(TL) -0.18 8-9 >999 180
WB 0.82 Horz(TL) 0.08 6 n/a n/a
(Matrix) Wlnd(LL) 0.02 9 >999 240 Weight: 86 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins.
BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation auide.
REACTIONS (lb/size) 2=2235/0-5-8, 6=2235/0-5-8
Max Hor7 2=47(LC 6)
Max Uplift2=-70(LC 7), 6=-70(LC 8)
Max Grav2=2274(LC 2), 6=2274(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/151, 2-10=-3290/3, 3-10=-3001129, 3-11=-2738125, 4-1 1=-2461148, 4-12=-2461149, 5-12=-2738/25, 5-13=-3001/29,
6-13=-3290/3, 6-7=0/151
BOT CHORD 2-9=0/2688, 8-9=011867, 6-8=012688
WEBS 3-9=-913/94, 4-9=-1/1060, 4-8=-1/1060, 5-8=-913/94
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.00 plate grip DOL=1.00
2) TCLL: ASCE 7-05; Pf=80.0 psf (flat roof snow); Category 11, Exp B; Partially Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 80.0 psf on overhangs non-concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 2 and 70 lb uplift at joint 6.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
???,D O Ll??, f
"".•v•ese 1{
ra, r,
s s
0P1 A L
August 18,2008
esign valid for use only with and ek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of components responsibility of budding designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the MiTei k
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding rQw.n +? r•a.uwM.
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criferla, DSB-89 and BCSII Building Component 7777 Greenback Lane, Suite 109
Safety Information available from Truss Plate Institute, 583 D'Onofno Drive, Madison, WI 53719.
Citrus Heights. CA. 95610
5X72 = - - 5.12 =
1
Job Truss
07064-8 A1LG
Alpine Truss, Montrose, CO - 81401
-1-
1-4-0
Truss Type
GABLE
m-n-n
10-0-0
6
N4 It
6.00 12 2x4 It 5
4
214 u
3
214 II 2s
Qty Ply Sagebrush / Sun Vail Condo / Enclosure
829141402
4 1
.Inh Refere7ae (Qptionah
7.060 s Aug 6 2008 MiTek Industries, Inc. Mon Aug 18 09:29:03 2008 Page 1
5x5 =
7
214 It
2x4 II
e
in-an
10-0-0
2x4 II
9
2e4 II
10
2xq II
17
26 2.4 II
12
I >t-4.n
t-4-o
stele = 1.38 s
1
,t
^x-?? -
d
' ? it Jx
°-</ XX
'r
ex
'
,
x
314 % D14 II 2x4 II 214 II 2x4 li 2x4 II 214 II 2x4 II 2x4 II 5a5 = 214 II 2x4 It 3.4
7n-n-n
20-0.0
I
Plate Offsets fX.Y): f16:0-2-8.0-3-01
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 80.0
(Roof Snow=80.0) Plates Increase 1.00 TC 0.10 Vert(LL) n/a n/a 999 MT20 169/123
TCDL 10.0 Lumber Increase 1.00 BC 0.07 Vert(TL) n/a n/a 999
BCLL 0
0 Rep Stress Incr NO WB 0.16 Horz(TL) 0.00 13 n/a n/a
.
BCDL 10.0 Code IRC2006IfP12002 (Matrix) Weight: 881b
LUMBER BRACING
TOP CHORD 2 X 6 SPF-S 16501' 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF-S 165OF 1.5E BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 WW Stud MiTek recommends that Stabilizers and required cross bracing be
installed during truss erectto n, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=249/20-0-0, 13=249/20-0-0, 19=230/20-0-0, 20=260/20-0-0, 21=269120-0-0, 22=270120-0-0, 23=1190120-0-0,
24=523/20-0-0, 18=260/20-0-0, 17=269/20-0-0, 16=270120-0-0, 15=190/20-0-0, 14=523/20-0-0
Max Horz 1=-46(LC 5)
Max Uplift2 I =-6(LC 8), 22=-11(LC 7), 23=-16(LC 7), 24=-37(LC 7), 17=-7(LC 8), 16=-12(LC 8), 15=-16(LC 8), 14=-37(LC 8)
Max Grav1=249(LC 1), 13=249(LC 1), 19=230(LC 1), 20=336(LC 2), 21=361(LC 2), 22=356(LC 2), 23=253(LC 2), 24=527(LC 2 )
, 18=336(LC 3), 17=361(LC 3), 16=356(LC 3), 15=253(LC 3), 14=527(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-125/79, 2-25=-129/29, 3-25=-37135, 3-4=-115/43, 4-5=-115/59, 5-6=-121/75, 6-7=-114/83, 7-8=-114/83, 8-9=-121/76,
9-10=-115/59, 10-11=-115/39,11-26=-37/19, 12-26=-129/13,12-13=-125179
BOT CHORD 1-24=0145, 23-24=0145, 22-23=0/45,21-22=0/45, 20-21=0/45, 19-20=0145, 18-19=0/45, 17-18=0/45,16-17=0/45, 15-16=0/45,
14-15=0/45,13-14=0145
WEBS 7-19=-203/0, 6-20=-309/7, 5-21=-336/22, 4-22=-323/28, 3-23=-249/29, 2-24=-453161, 8-18=-309/3, 9-17=-336/22,
10-16=-323/28, 11-15=-249/29, 12-14=-453/61
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.Opsf; BCDL=6.Opsf; h=25ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left
and right exposed ; end vertical left and right exposed; Lumber DOL=1.00 plate grip DOL=1.00
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable
End Details as applicable, or consult qualified building designer as per ANSI/TPI 1-2002. P9 0 LlC
3) TCLL: ASCE 7-05; Pf=80.0 psf (flat roof snow); Category 11; Exp B; Partially Exp.; Ct= 1 ?? jI
?
4 Unbalanced snow loads have been considered for this design. ? + . ?
R? rJ
+
5) Gable requires continuous bottom chord bearing. Ca
4
*,
+
6) Gable studs spaced at 1-4-0 oc. ,.
4
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. : p s
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 Ib uplift at joint 21, 11 Ib uplift al joint,32, 15Ib
_Io
{,[
c
uplift at joint 23, 37 Ib uplift at joint 24, 7 Ito uplift at joint 17, 12 Ito upliff at joint 16, 16 Ib uplift at joint 15 and 37 Ib uplift at joint 14. %;]
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
August 18,2008
??
Design valid for use only with Wei, connectors. This design is based only upon parameters shown and is for an individual building component.
Applicability of design poromenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity, of the i? k
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. Fo, general guidance regarding Fow?+ro.4n.on.x
fabrication, quality control, storage, delivery. erection and bracing, consult ANSI/TPII Quality Crifedo, DSO-89 and BCSII Building Component 7777 Greenback Lane, Suite 109
Safety Information available from Truss Plate Institute, 583 D'Onofno Nye, Madison. WI 53719. Citrus Heights. CA. 95610
w
D w
CL. rn
D
-_v
rt
C) nw0-°Za
c.N fl fl n
O :-c
,
:n D0-Clb•ro- a
O
(D 5 n
??o(a NOQ CSC a;
-
mpg nQ:O
a. 0 3 (D (D 3{
0
s -. o a
?aa-0a-
(a ?
00 5. "D O a. a ?, 5 n 0 00
Q(aa(o'ro cD ?n
CD N n. --, a Q. 0 a; n '
n CQ < (D
a Q 0 O O
CD 3 p a s
?2 (D
(a ?. C a
n C 6
? _' C
-`
O
O
? O (a
3 't
F
7I! !?
7
ro
ro t
7 3 (D
A } I
n
ro ?
N
ro
ro
3
V
w
I V
O
O
D`
F
A,
(fl
A
(D
a
06Q
n
Q ? X a
m c -. a-
amm?
K
-0
°CT
map
3 (a
ono
oo?
s'Q
Q°a
?• 3 0
(D ,
m
X N
m
m ° a
5(Da3
? p c m
oa.Oo
7Z 3 (D
o (D -a 3
O (D
O O Qa
r o
,Cm
R
,0Z °mn n x
?MIr n o
p A W W N C
ao ,o
V P (D 70 0
pZ?m is n
'A O v
° u C, m
ao. °. w
Q, - v cn D
v ?
A ?' O
C) '
W p
o
o
0
0
cc
3
3m
A G
C w
W ?
? n
n
3
m
0
0
C)
O 9 v
3D p
(
a 3s
oap
v_ (D
n
cpO a
p (D
o n7
O
xn =-A0 co
30 07
r^Z?
"vD
NY ?rn
r Z m M
O -m
cm
N N V
M A Z
?c
m 03
> rn
M y m my
m
v
5 A r
Ao
m
a
O v?
m
O
P?
ID
(a ? a
O ON
p
? n
O O0
D- n
(D
TOP CHORD
c(-e
n ti
m
m
w2-7
O
Z-
n
O
A
N y
P W
M N
r
`?.
rn
-
O
h
W O
A s .?
Z N
a ?m Z
a? ? CD v
Q-O
mQ?mQ rn
3?a5, m` Z
(D 0 (D D
asIgo
S Im-O
CD Z
?((DD?• m
(D
o (D x
+ C I
o
CO
N a
3 ?•
m
. '^
30
a ?
c
7
O
w o3
tD K-
tD
ro
3
TOP CHORD
-- p w N -
N
m 6 f. ^ a a
w nav ? ? noaN ?a
_
o r W N NC 3j ?mN
-° D n m m p
m n3 fl
°. 4 m o ?- qty =? -•Q
o
3 m 3 m Il N 7 O
fl o
_
o m
Z8 ?c7 n ° oa m° 3 0-
3 03 f.? n ?n S-0 m n o'0
3C'v 7
°
fl ?3m 3<° fl ?o ? ?3 S m?° ?aV mx
?a ?? n3? m
m? oa 3Q°3 04
z
0 m o -
=
?
o w m
_. no
w
a
a
F o
T
m
o -
mn
n c
Q .
a Hof ?
? °
a
m 0 -
y D? °a
0 ?a ° a
°
m N
m o m
m 3?
m
` ma
w a a°o 0m m
-6.Q 5'a
m
ro
?? a ?
o
o° a n 3
m° nN
mo m
a
?.o aN a
fl
o ??
ao : a
nK3 m c N
g o-o °
ate 0. m
?R<m n o
.
p3 Oa m °-? a
' o
7°- o ? m
a6
fl
cr
o ?c
3 o
om aem om
m
a
n ?
=L m
N
m2
t .
m?
a0 1
-
o
n on
nm v- m
<
p 5 7 mro
7 5 ?n m
_.C O ?„ o
m , n n
C-.. an a oa n
O w
n
cr o
7
N 9
C p c
m
m n 7
O
0? bon
o n
rn„ f
N a m 00o 3o aq
-03m o o '5 .3 a=
u
S° ? 3 q <°m
>Y " o z
°m
0 °p
m n, a3 co
o a
g
N
no ry0 O Sa O m O ? m9 S 57 On ,
ma m co f n
? n V
0 6
?c m pO? 3 0
j m m
c-0 ?m a?
Q a mm
-0 ?n 5,oo
(01
7 ' o C? 3j?
m ?? -aN
of "' o 0
N NO v°
fl3 mn
n -0
?•
3
a
n
Q O
c
N
1
N
N n p
W O NN
MOV 6? NQ
?n n
N K
N? j
ff
O
n7
am
j
N.
,
<
m n
CD
> > o m n
33 n o
s.n 'mo
,
mo om 9,0 m m
C) ° o
n 16 a?
a n? 3
Nm
O -" n 0
<
o n: -0 v' lQ 7 ' nj
0 o (O
n (D p D O
3n
_ O '-• -- o S 7 3 `
??
o o m a 7
a 3 7?
m N cn
,
n
o ?
n w ma 6
o n
m ?
S° 'a n ma n
' o m
o.-o n 5 3 n 9
n m
C.
3.
n
° m 6 m_ N o 3 ° a o n c
o
V;- OL < o o
-
?°F
n o °
? n '
m
?
n
CD 0 on S -
o
o o ° a ° ?
N o m
?o
3
3 Q
m a
? D
CD m
o
n 3
6
or
m
3 0
D
r'
m
D
r
00
D
n
Z
O
n
O
Z
0 -n
0
C
Q W
(D O
O -In
-5 O
O
O
O n
O
Q Q
? Q
C
(D
O
O
0
Q
n
r?7
m?m
?V
N
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MWN0FV1A '
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149
ELECTRICAL PERMIT Permit #: E08-0281
ACOM
Job Address: 645 N FRONTAGE RD W VAIL
Location.....: SUN VAIL
Parcel No...: 210106316026
OWNER BUGGY, DALE R. 11/18/2008
645 N FRONTAGE RD W 13-C
VAIL
CO 81657
APPLICANT D. JENSEN ELECTRIC INC.
P. O. BOX 1221
GYPSUM
CO 81637
License: 135-E
CONTRACTOR D. JENSEN ELECTRIC INC
P. O. BOX 1221
GYPSUM
CO 81637
License: 135-E
11/18/2008 Phone: 970-904-7065
11/18/2008 Phone: 970-904-7065
Desciption: WIRING FOR WILDLIFE-RESISTANT TRASH ENCLOSURE
Valuation: $1,500.00 Square feet: 0
Project #:
Status...:
Applied .. :
Issued .. .
Expires. .:
PRJ08-0344
ISSUED
11/18/2008
11/18/2008
05/17/2009
**..*....***«„*****«,,«„*«„*«.«*,«««„«..««.,*.,.******* FEE SUMMARY *««««,..*.**..***.**.*«**..«*.«*«,,.,.*...*....**.***.*«**
Electrical Permit Fee--------- > $57.50 Total Calculated Fees--> $61.50
Investigation Fee--------------> $0.00 Additional Fees ---------- > $0.00
Will Call Fee--------------------> $4.00
Use Tax Fee------------------- > $0.00 TOTAL PERMIT FEE---> $61.50
Total Calculated Fees ------- > $61.50 Payments-----------------> $61.50
BALANCE DUE---------- > $0.00
APPROVALS
Item: 06000 ELECTRICAL DEPARTMENT
11/18/2008 JLE Action: AP
CONDITIONS OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that
all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state
laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and
Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR
OFFICE FROM` 0 A - 4 PM.
Signature of Owner or Contractor Date
P _ J e 11 12
Print Name
elec_prm_041908
TOWN OF VAIL, COLORADO Statement
Statement Number: R080002215 Amount: $61.50 11/18/200801:51 PM
Payment Method:Credit Crd Init: JLE
Notation: DONALD C
JENSEN JR
-----------------------------------------------------------------------------
Permit No: E08-0281 Type: ELECTRICAL PERMIT
Parcel No: 2101-063-1602-6
Site Address: 645 N FRONTAGE RD W VAIL
Location: SUN VAIL
Total Fees: $61.50
This Payment: $61.50 Total ALL Pmts: $61.50
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 57.50
WC 00100003112800 WILL CALL INSPECTION FEE 4.00
T 0 W N OVARL*
Development Review Coordinator
75 South Frontage Road
Vail, CO 81657
Phone 970-479-2128
Fax: 970-479-2452
Inspections: 970-479-2149
ELECTRICAL PERMIT APPLICATION
Project Address
Contractor Information
Company:
Company Address: -4O?6 1Z z-
City: State: cPr zip: Contact Name:
Contact Ph: Cell:
E-Mail:
Town of Vail tractor R ' tration No:
X 77:
Contract6fr?gnature (req d)
Property Information
Parcel #:
Legal Description: Lot # Blk #
Subdivision:
-??
Job Name:
Owner Name:
Mailing Address: ??Z f iZ?n?fr r1 ???
(For Parcel # Contact Eagle County assessors`dffice at 970-328-8640 or visit
www.eaglecounty.us/patie)
Architect () Designer () Engineer ( )
Name:
Phone:
Fax:
E-Mail:
V '1 q 25
?oI.SU
py?t?
q-v-.?n?-000g? ltd
Project #: T RJ (1 r)--:; 44
Building Permit #:_9 ?y
Electrical Permit #: LOS ` ( 1 n
Detailed Description of Work: ?lz .,?z.Y--
(Use additional sheet if necessary)
COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND
VALUATION OF WORK (Labor & Material)
Amount of SQ Ft
Electrical $
Work Class:
New 0 Addition ( ) Remodel ( ) Repair ( ) Other ( )
Building Type: -
Single-Family ( ) Two-Family ( ) Multi-Family ( )
Commercial ( ) Townhome ( ) Other (>'?
Date Received:
C' jgs'e' J
03-02-2009
4:08 DIM
A/P/D Information
Activity: B08-0254
Const Type:
Owner: BUGBY, DALE R.
Inspection Request Reporting
Vail, CO - City Of
Requested Inspect Date: Tuesday, March 03, 2009
Inspection Area: JRM
Site Address: 645 N FRONTAGE RD W VAIL
Type: A-COMM Sub Type: ACOM
Occupancy: NA Use: VB
Contractor: SAGEBRUSH SERVICES Phone: (970) 524-1031
Description: COMMON ELEMENT: WILDLIFE-RESISTANT TRASH ENCLOSURE
Reauested Insoection(sl
IAIuzS
Page 5
Status: ISSUED
Insp Area: JRM
Item: 90 BLDG-Final C? Requested Time: 10:00 AM
Requestor: SAGEBRUSH SERVICES Phone: (970) 524-1031
Assigned To: JMONDRAGON Entered By: JMONDRAGON K
Action: Time Exp:
Comment: UU burrutU i NUSS REPORT STILL N=U ACCESS PANEL TO ATTIC AND TO VIEW TRUSSES/_ A
C.,Q Z? ? ?f
Inspection History
Item: 10 BLDG-FOOTING "Approved"
08/13/08 Inspector: GCD Action: CR CORRECTION REQUIRED
Comment: 1.THERE IS A LARGE THROUGH VOID INT HE WEST COLUMN CONCRETE. AN ENGINEERS
FIX IS REQUIRED.
2.FOUNDATION WALL IS SHOWN AS CONTINOUS AT SLAB LEVEL. FOUNDATION DOESN'T
&STRIP FOOTING APPEARS TO BE UNDERMINED.
4.STRIP ALL FORMS FOR BOTH ENCLOSURES RECALL INSPECTION.
10/08/08 Inspector: JGG Action: AP APPROVED
Comment: Footing was reinspected with foundation wall on 8/29/08.
Item: 20 BLDG-Foundation/Steel * Approved **
10/08/08 Inspector: JGG Action: AP APPROVED
Comment: Reinspection of foundation OK, corrections completed on 8/29/08.
Item: 30 BLDG-Framing ** Approved **
10/08/08 Inspector: JRM Action: APCR APPROVED/CORRECTION REQD
Comment: FRAMING APPROVED WITH CONDITIONS..
STAMPED TRUSS REPORT REQUIRED
ELECTRICAL INSPECTION REQUIRED
Item: 60 BLDG-Sheetrock Nail ** Approved **
12/31/08 Inspector: SHAHN Action: APCR APPROVED/CORRECTION REQD
Comment: SCREWS ARE APPROVED.
PROVIDE STAMPED TRUSS DRAWINGS AS NOTED ON FRAMING INSPECTION.
DID NOT LOCATE ATTIC ACCESS (REQUIRED IF ATTIC CLEAR SPACE IS 30 INCHES)
Item: 70 BLDG-Misc.
.
Item: 90 BLDG-Final
02/26/09
Comment: Inspector: JRM Action: DN DENIED
GC SUPPLIED TRUSS REPORT STILL NEED ACCESS PANEL TO ATTIC AND TO VIEW s
TRUSSES
Item: 537 PLAN-FINAL C/O ** Approved **
02/25/09 Inspector: Warren Action: AP APPROVED
Comment:
REPT131 Run Id: 9287
E08 -0281 : Entries for Item: 190 - ELEC -Final 14:54 01/24/2013
Action
Comments
By
Date
Unique_
Key
AP
CONTRACTOR CANCELLED DURING
MDENNEY
02/06/2009
A000122
PHONE CALL.
744
AP
TRASH ENCLOSURES.
MDENNEY
02/06/2009
A000122
774
Total Rows: 2