Loading...
HomeMy WebLinkAboutM09-0005NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT mww 000 Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 4640 MEADOW DR VAIL Location.....: BUILDING 10, UNIT 19 Parcel No...: 210112405019 OWNER KARPA, MICHAEL P. & LEE A. - 01/07/2009 SUZANNE H. - WADDINGTON, IAN PETER -JT 12 BUNKER HILL RD IPSWICH MA 01938 APPLICANT PLUMBING & HEATING DESIGN LL 01/07/2009 Phone: 970-376-7776 P.O. BOX 944 AVON CO 81620 License: 359-M CONTRACTOR PLUMBING & HEATING DESIGN LL 01/07/2009 Phone: 970-376-7776 P.O. BOX 944 AVON CO 81620 License: 359-M Desciption: REPLACE OLD BOILER & WATHER HEATER WITH A NEW BOILER & WATER HEATER SIDE ARM Valuation: $3,500.00 ***##**#*****#*********#####*####%*#****fi*************************#*#********##*FEE SUMMARY*****************..___....********#********#*##***********#*#*************************** Mechanical Permit Fee---> $80.00 Will Call ------------ > Plan Check ------------------- > $20.00 Use Tax Fee------ > Investigation-----------------> $80.00 Total Calculated Fees--> $4.00 Total Calculated Fees ---> $0.00 Additional Fees-----------> TOTAL PERMIT FEE---> $184.00 Payments-----------------> BALANCE DUE--------- > $184.OC $0 OC $184.OC $184.OC $O.Oc APPROVALS Item: 05100 BUILDING DEPARTMENT 01/14/2009 cgunion Action: CR incomplete submittal emailed applicant 02/09/2009 cgunion Action: AP APPROVED REVISED, CORRECTED PLAN CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED ALL TIMES Permit #: M09-0005 Project #: PRJ09-0007 Status ...: ISSUED Applied ..: 01/07/2009 Issued . .: 02/11/2009 Expires . .: 08/10/2009 m ech ca n i ca I_perm it_041908 MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. xxxxxx. xxxxxxxxxxxxxxxxxxxxxxxxx,exxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx .rxxxxxxxxxxxxxxxxxxxrwxxxxxxxxxxxxxxxxxxxrxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. Signature of Owner or Corgractorr 'Date I Print Name mechcanical_perm it_041908 Development Review Coordinator 75 South Frontage Road .. Vail, CO 81057 Phone, 970-479-2128 R Fax: 970-479-2452 Inspections: 970-479-2149 Tff V TOWN OF VAIL MECHANICAL PERMIT APPLICATION The followina items MUST be attached to this permit aoolication Mechanical Room Lavout drawn to scale to include: _ Mechanical Room Dimensions _ Combustion Air Duct Size and Location Flue, Vent and Gas Line Size and Location Equipment Cut / Spec Sheets Project Address i1 C) t qi T- CL-C45 inn Project #: AOl(/J CA • DL-0-1 Building Permit #: Contractor Information Company?A t) LIL. Mechanical Permit #: P ?L"" 6, Detailed Description of Work: R?_t7La.G c?Lb 60/(_? Company Address: i' U UX ?- 7 t- v-A-rc< 14CArert okJg.w' AoeILf tT? City: A vv A J State: CD Zip: _ &"2& ('?;?C S i t,?_ A Contact Name: Aict-14"L f'9 C'w0F7D^) Contact Ph:, Cell: "10-37y, )AA E-Mail: 1nv[.dC v''Qt LWMd Lf41( . CC - Town of Vail Contractor Registration No: X Contractor Signature (rewired) Property Information FF11 Parcel #: ? 10 t 1 1 ?11 V ?? CD Legal Description: Lot # Blk # Subdivision: Job Name: Jk A L ei_ r-ArzP `\ Owner Name: 104 A ? L _1- LY T 1<'A 0 P/? Mailing Address: ?? Ilt?n/?/l L bu, r?l 4 3 f? (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Architect () Designer () Engineer ( ) Name: Phone: Fax: E-Mail: (Use additional sheet if necessary) Complete Valuation for Mechanical Permit: Mechanical $ '??. ,',:; <2 _ ° o Work Class- New ( Addition ( ) Remodel ( ) Repair ( ) Other ( ) Boiler Location: Interior ( Exterior ( ) Other ( ) No/Type Existing Fireplaces: Gas Appliances( ) Gas Logs (?) Wood/Pellet ( ) No/Type Proposed Fireplaces: Gas Appliances( ) Gas Logs ( ) Wood/Pellet ( ) Building Type: Single-Family ( ) Two-Family ( ) Multi-Family lv? Commercial ( ) Townhome ( ) Other ( ) Date Received: N ., 6 2109 ?'';.a IR JA I__ TOWN OF VAIL, COLORADO Statement Statement Number: R090000146 Amount: $184.00 02/11/200902:14 PM Payment Method: Check Init: JLE Notation: 1285 PLUMBING & HEATING DESIGN Permit No: M09-0005 Type: MECHANICAL PERMIT Parcel No: 2101-124-0501-9 Site Address: 4640 MEADOW DR VAIL Location: BUILDING 10, UNIT 19 Total Fees: $184.00 This Payment: $184.00 Total ALL Pmts: $184.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 80.00 PF 00100003112300 PLAN CHECK FEES 20.00 PN 00100003153000 INVESTIGATION FEE (BLDG) 80.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 e W v1 g 7 #s o- o c? 1 t ?? 4 J ` - V V lzac F(61/28/2009) Greg Denckla - Permit M09-0005 Vail Racquet Club Building 10 unit 19 Karpa Boiler installation Page 1 From: Greg Denckla To: mpcvail@hotmail.com Date: 01/28/2009 12:15 PM Subject: Permit M09-0005 Vail Racquet Club Building 10 unit 19 Karpa Boiler installation CC: Chris Gunion; Martin Haeberle Michael, This e-mail is to recap our field meeting yesterday. The mechanical permit is not approved at this time. The boiler installation does not meet minimum code requirements, or the boiler installation instructions for clearances to combustible construction or maintenance requirements. Also the combustion air is inadequate for the size of the boiler. I order for the permit to be approved and issued compliance with all applicable code and installation requirements is required. The floor finish is of a non-combustible material, it is concrete. The stated clearances in the installation instructions are minimum clearances from combustible construction and also for inspection and maintenance. Only the manufacturer can approve reduced clearances. The vent connector requires a minimum 6 inch clearance to combustibles see International Fuel Gas Code sections 503.10.5, 503.7.7, and Table 503.7.7. The combustion air opening has to be verified that it is to the exterior of the building and that there is enough area for 125,000 btu's. In this instance we would allow an combination of air by infiltration and outside combustion air. As I calculated air by infiltration alone would require 6,250 cubic feet. Combustion air from one opening at one square inch per 3000 btu located high would be 41 square inches. What we need from PDH LLP Plumbing and Heating is a detailed mechanical plan showing compliance with all code and installation requirements. Our meeting is not an approval of any installed non-complying conditions. Greg Denckla Town of Vail Senior Building Inspector p:970-479-2321 f:970-479-2452 (01/21/2009) Chris Gunion - M09-0005 From: Chris Gunion To: mpcvail@hotmail.com Date: 01/14/2009 8:29 AM Subject: M09-0005 CC: Jennifer Eliuk Michael, We received a mechanical permit application for a new boiler and water heater storage tank at the Vail Racquet Club building 10, unit 19. In order to process the application there are a couple of items still needed. (2) copies of plans and specifications are required. 1. Please include a floor plan view of the mechanical room draw to scale. Show clearances from walls to the boiler, and working clearances in front for boiler. Include entry door location and size. 2. Include equipment sheet on the water storage tank proposed 3. Include combustion air duct sizes and location 4. Include b-vent size and gas line sizes 5. Show location of floor drain and indicate in mechanical room floor is combustible, or non-combustible. thanks Chris Gunion I.C.C Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2369 cgunion@vailgov.com Page 1 Development Review Coordinator 75 South Frontage Road Vail, CO '8 657 97 Ph Fax P9-479-2128 1U1f11.UL 11ti,, .>? Inspections: 970-4792149 mmnpn??)rntt?? ??tttt ? , ..,.? L Transmittal Form Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: Attention: [A01- 0 0r`? rA i f ( _?> () Revisions ( Response to Correction Letter j _attached copy of correction letter () Deferred Submittal () Other Project Address: t , Contact Information Company: %L..i'•;l =-t7`Z i v . ?`.>J? j G AJ Company Ph:°, 1 7 7" ''l 6 Fax: Contact Name: 1 C ?. -( A£ C- Contact Ph: Cell: E-Mail: Town of Vail Contractor Registration No: Signature (required) Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building $ Plumbing $ Electrical $ Description / List of Changes: (Use additional sheet if necessary) Mechanical $ Fire Sprinkler/Alarm $ Total $ 0.00 Date Received: L i JAN 2 0 2009 TOWN OF VAIL y1 02-25-2009 Inspection Request Re orting Page 15 4:08 Dm Vail, Cpl-Of Requested Inspect Date: Thursday, February 26, 2009 Inspection Area: XX Site Address: 4640 MEADOW DR VAIL BUILDING 10, UNIT 19 A/P/D Information Activity: M09-0005 Type: B-MECH Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: XX Owner: KARPA, MICHAEL P. & LEE A. - FORKUSH, Contractor: PLUMBING & HEATING DESIGN LLP Phone: 970-376-7776 Description: REPLACE OLD BOILER & WATHER HEATER WITH A NEW BOILER & WATER HEATER SIDE ARM Reauested Insoecx#dKilsl ,Item. 390 MECH-Final ,i Requested Time: 03:30 PM Re?uestor: PLUMBING & HEATING DESIGN ! LP Phone: 970-376-7776 Co ments: we 376-7776 r - -? Assign : JMONDRAQD ----- Entered By: JMONDRAGON K Action: Time Exp: Comment: proviae arart stop for B vent. bond csst per manufacturer's instruction or replace with approved materials. insulate first five feet of hot water per IECC. (4 A Insoection History ` I Item: 200 MECH-Rough Item: 315 PLMB-Gas Piping Item: 390 MECH-Final 02/24/09 Inspector: shahn Action: CR CORRECTION REQUIRND - `/ Comment: provide draft stop for B vent. bond csst per manufacturer's instruction or replace with approved materials. f? insulate first five feet of hot water per IECC. 1 ? s r I I ?i REPT131 Run Id: 9257