HomeMy WebLinkAbout500D Updated for all colors 11-29-2016
PREPARED AND CHECKED BY AUTHORIZED BY
FOR FITI FOR FITI
YUN JUN, SONG MOON-OK NOH
QUALITY MANAGER PRESIDENT
※ Report Verification No.: QBPY-KP68-G2K3 ※
(You can see the authenticity of your test report through the above "Report Verification No." at FITI homepage.)
TEST REPORT
APPLICANT : REPORT NO. : T214-15-00188
SAMPLE RECEIVED DATE : 2015-01-22
TEST STARTED DATE : 2015-01-22
REPORT ISSUED DATE : 2015-01-28
PAGE : 1 OF 3
SAM SUNG DYEING CO., LTD.
SAMPLE DESCRIPTION : ONE(1) PIECE OF SUBMITTED CUTTING SAID TO BE WOVEN FABRIC.
======================================================================================================
ITEM : POLY 500D
======================================================================================================
TEST CONDUCTED : AS REQUESTED BY THE APPLICANT, FOR DETAILS PLEASE SEE ATTACHED PAGES.
======================================================================================================
REPORT NO. : T214-15-00188
PAGE : 2 OF 3
TEST CONDUCTED TEST RESULT
======================================================================================================
(01) FLAMMABILITY ( CPAI 84, SECTION 6 WALL & TOP MATERIAL : 1995 )
#1
AS RECEIVED
AFTER FLAME TIME(s)
- WARP 0 0 0 0 // 0
- WEFT 0 0 0 0 // 0
DRIP BURN(s)
- WARP 0 0 0 0 // 0
- WEFT 0 0 0 0 // 0
DAMAGED LENGTH(mm)
- WARP 133 130 126 135 // 131
- WEFT 130 136 122 125 // 128
NOTE) CONCLUSION : BASED UPON THE RESULTS OF THE TEST REPORT, THE SUBMITTED SAMPLE MEETS
THE PERFORMANCE REQUIREMENTS FOR WALL AND TOP MATERIAL AS STATED IN CPAI 84,
SECTION 6.
ACCEPTANCE CRITERIA : FABRIC WEIGHT (g/㎡) : MORE THAN 200 BUT NOT MORE THAN 270
DAMAGED LENGTH : Max.Avg. 165 mm Max.Ind. 255 mm
AFTER FLAME : Max.Avg. 2.0 s Max.Ind. 4.0 s
DRIP BURN : Max.Avg. 0 s Max.Ind. 0 s
TEST WAS CONDUCTED ONLY IN THE ORIGINAL STATE BY THE CLIENT'S REQUEST.
(02) FLAMMABILITY ( CPAI 84, SECTION 5 : 1995 )
#1
AS RECEIVED
PASSED SPECIMENS (EA) 4
FAILED SPECIMENS (EA) 0
CHAR LENGTH(mm) 28 30 26 33
NOTE) REQUIREMENT : NO SPECIMEN SHALL BE DAMAGED WITHIN 25 mm OF THE EDGE OF THE HOLE
IN THE FLATTENING FRAME.
CONCLUSION : THE SUBMITTED SAMPLE MEETS THE REQUIREMENTS OF CPAI-84 SECTION 5
FOR FLOORING MATERIAL WHEN TESTED IN ITS ORIGINAL STATE.
REPORT NO. : T214-15-00188
PAGE : 3 OF 3
TEST CONDUCTED TEST RESULT
======================================================================================================
(03) FLAMMABILITY ( NFPA 701, TEST METHOD 2(FLAT MATERIAL) : 2010 )
SAMPLE NO. AFTER FLAME TIME(s) DRIP BURN(s) CHAR LENGTH(mm)
1 0 0 283
2 0 0 295
3 0 0 299
4 0 0 265
5 0 0 268
6 0 0 311
7 0 0 267
8 0 0 278
9 0 0 281
10 0 0 295
AVG. 0 0 284
NOTE) ㆍCONCLUSION : BASED UPON THE RESULTS, THE SUBMITTED SAMPLE MEETS PERFORMANCE
REQUIREMENTS AS STATED IN NFPA 701 TEST METHOD 2 (2010)
ㆍACCEPTANCE CRITERIA
AFTER FLAME TIME(s) DRIP BURN(s) CHAR LENGTH(mm)
MAX. IND. <2 MAX. IND. <2 MAX. IND. <435
ㆍTEST WAS CONDUCCED ONLY IN THE ORIGINAL STATE BY THE CLIENT'S REQUEST.
======================================================================================================