Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutA005.1AWINDOW SCHEDULE
OPENING
NUMBER
OPENING
TYPE
GLASS
TYPE
FUNCTION NEW/EXIST COMMENTS
002
003
004
103
104
106
107
108
109
110
111
112
113
114
115
116
117
118
202
203
204
205
206
207
208
209
210
211 A/B
212 A/B
213 A/B
S1
S35
S2
S4
S3
S4
S5
S7
S8
S9
S10
S9
S8
S13
C1
C2
C1
FIXED
FIXED
FIXED
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
216
219 A/B
302 S31
305 S31
308 S31
311
314
214 A/B
215 A/B
217 A/B
218 A/B
220 S14
303 S15
304 S16
306 S16
307 S15
309
310 W2
312
313
315
316
NEW
NEW
NEW
NEW
NEW
NEW
NEW
319
322
325
328
317
318
320
321
323 S16
324
326
327
329 W1
330
333
331
332
334
335
HEAD JAMB SILL
WINDOW SCHEDULE
OPENING
NUMBER
OPENING
TYPE
GLASS
TYPE
FUNCTION NEW/EXIST COMMENTS
401
402
403
404
405
406
407
408
409
411
412
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
HEAD JAMB SILL
S23
S19
S24
S18
S19
S20
S23
S18
S29
W3
S33
S28
S28
S27
S21
S25
S22
S26
S21
C4
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
W3
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
W2
EXIST.
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
S34
NEW
S16
NEW
S16
NEW
S34
NEW
S16
NEW
NEW
W1
NEW
W1
NEW
W1
NEW
W1
NEW
W1
NEW
W1
NEW
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
CENTER
PIVOT
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
FIXED
DARK BRONZE ALUM.
STOREFRONT TO MATCH
ADJACENT EXIST.
STOREFRONT
MTL. PANEL BELOW TO
MATCH EXIST. (219)
REF. SHEET A130A.1A
IG-1
IG-1 / IG-3
IG-1 / IG-3
IG-1 / IG-3
IG-1 / IG-3
IG-3
IG-1
IG-1 / IG-2
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IG-2 / IMP
IG-1 / IMP
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
ADD ALTERNATE NO. 1
DARK BRONZE ALUM.
STOREFRONT TO MATCH
ADJACENT EXIST.
STOREFRONT
DARK BRONZE ALUM.
STOREFRONT TO MATCH
ADJACENT EXIST.
STOREFRONT
221 S12
NEW FIXED
IG-1
DARK BRONZE ALUM.
STOREFRONT TO MATCH
ADJACENT EXIST.
STOREFRONT
IG-1 / IG-3 / IMP
IG-1 / IG-3 / IMP
IG-1 / IG-3 / IMP
IG-1
IG-1 / IMP
IG-1 / IMP
IG-1 / IG-2 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1 / IG-2 / IMP
IG-1 / IMP
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1 / IG-2 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IMP
IG-1 / IG-3 / IMP
IG-1 / IMP
NEW
FIXED
NEW
FIXED
IG-1 / IMP
410 S41
NEW
FIXED
IG-1
S41
S41
413 S32
IG-1
IG-1
437 S41
NEW
FIXED
IG-1
438 S41
NEW
FIXED
IG-1
NEW
FIXED
111A S39
NEW FIXED
110A S38 NEW
FIXED
108A S38
NEW FIXED
107B S37
NEW
FIXED
107A S36
NEW FIXED
414A S30
NEW
FIXED
IG-1 / IMP
103A
NEW
FIXED
DARK BRONZE ALUM.
STOREFRONT TO MATCH
ADJACENT EXIST.
STOREFRONT
IG-1
S6
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
CENTER
PIVOT
5
5
5
5
IG-1 / IG-3
IG-1
IG-1 / IG-3
IG-1 / IG-3
IG-1 / IG-3
106A
106B
S1
NEW
FIXED
IG-1
S1
NEW
FIXED
IG-1
30
DELETED
DELETED
DELETED
5'-2 7/8"
3'-8"
4'-0" TYP. OF 5. RE: 21/A611.1A
W4
B
ONE WAY MIRROR WINDOW FILM-
SILVER, VISIBLE FROM
THERAPIST WORKSTATIONS;
REFLECTIVE FROM PHYSICAL
THERAPY TREATMENT AREA SIDE.
3'-0" 3'-8"
8'-0"
W7
A
3'-8" 3'-0" 5'-0"
W8
A
3'-0"
3'-0" 3'-0"
W10
A
3'-6" 5'-0"
5'-0"
W11
A
3'-6" 4'-0"
W13 3'-0"
48
A.S.
3'-0" 4'-0"
3'-0"
W14
A
4'-0"
3'-6" 3'-0"
W12
48
A.S. 2"
HOLLOW METAL WINDOW JAMB
A SCALE: 1 1/2" = 1'-0"
STOREFRONT METAL WINDOW MULLION
BSCALE: 1 1/2" = 1'-0"
GLAZING
HM FRAME
SEALANT
DOUBLE METAL
STUD AT HEAD AND
SILL
C
DOUBLE 20 GA. STUDS
AT JAMB, TYP.
MTL. STUDS W/ SOUND
ATTENUATION BLANKET. SEE
PARTITION TYPES
CONT. SEALANT EA. SIDE. ALUM
FRAME AT DRYWALL
SHIM AS REQUIRED BY MANUF.
GYP. BD RETURN
ALUMINUM CHANNEL JAMB
D SCALE: 1 1/2" = 1'-0"
SOFFIT OR HEADER ABOVE RE:
INTERIOR ELEVATIONS
CONTINUOUS ALUMINUM
FRAME (MATCH VERSATRAC)
GLAZING SEALANT TO ALUM
FRAME, CONT. BOTH SIDES
1/4" TEMPERED GLASS PANEL
GYP. BD. WRAPPED HEAD,
SILL, AND JAMBS, TYP.
SEALANT, ALUMINUM
FRAME AT DRYWALL
JAMB (CONTINUOUS
BOTH SIDES)
EQ EQ
ALUMINUM CHANNEL SECTION
SCALE:
1 1/2" = 1'-0"
1/2" TEMPERED GLASS
HOLD
2"
ROOM SIDE
ROUND EDGE OF EXPOSED
GLASS SMOOTH.
GLAZING
SPLAYED MULLION
ALUMINUM STOREFRONT
2"
LEAD LINED WINDOW FRAME
A.S. SCALE: 1 1/2" = 1'-0"
RADIATION SHIELDED
GLASS
VOICE PASSAGE
DOUBLE METAL STUD
AT HEAD AND SILL
CONTROL ROOM SIDE
LEAD SHIELDING AT INSIDE OF
FRAME PROFILE, CONTINUOUS
AROUND OPENING
WINDOW FRAME
RADIATION ROOM SIDE
LEAD-BACKED DRY WALL
48
CURVED SOLID SURFACE TOP, 1/2"
OVERHANG BOTH SIDES
SHIM
RUNNER TRACK
METAL TUBE HORIZONTAL
WELDED TO POSTS
METAL 3"X3" TUBE POST
BACKER ROD & SEALANT
STOREFRONT
SATIN ANODIZED "J" CHANNEL
5/8" GYP. BD
6" METAL STUD
EXPANSION ANCHORS
STEEL BASE PLATE
RUNNER TRACK
BACKER ROD & SEALANT
SHIM
STOREFRONT
LATERAL BRACE ABOVE CEILING
CEILINGS, RE.
REFLECTED CEILING
PLANS AND FINISH
SCHEDULES
ALUMINIUM STOREFRONT
SPLAYED MULLIONS
BACKER ROD AND SEALANT
SHIM
HALF WALL RE: PARTITION
METAL STUD
5/8" GYP. BD WRAP
N
This document is the property of Heery International, Inc. and Heery International Inc. retains all
rights therein, including copyrights. It may only be used in a manner consistent with Heery
International Inc.'s rights while Heery International, Inc. is providing services for the specific project
identified or referred to herein or extensions thereto. It may not be used for any other purpose
except with the express written agreement of, and compensation to, Heery International Inc.
Copyright © 2013 by Heery International, Inc. all rights reserved.
WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42"
drawn by checked by
sheet number
sheet title
item date
date
issued for
seal/signature
consultants/construction managers
owner's project number
project number
Heery International
555 17th Street, Suite 500
Denver, CO 80202
720.946.0276
OWNER'S PROJECT NUMBER
TOV:
C&S PRJ14-0157 B15-0185 (ADD#5)
TI PRJ14-0157 B15-0461 E15-0043 (ADD#6)
DFPC:
C&S 9667 (ADD#5)
TI TBD
7/27/2016
10:13:22 AM
A005.1A
Checker
Author
STOREFRONT AND
CURTAIN WALL
02/06/2016
CONSTRUCTION
DOCUMENTS
VAIL VALLEY
MEDICAL CENTER
PHASE 1 - WEST WING
181 WEST MEADOW DRIVE
VAIL, CO
HII-1302604
INTERIOR DESIGN:
Gallun Snow
1920 Market Street,
Suite 240,
Denver, CO 80202 720.407.6002
MECHANICAL, ELECTRICAL,PLUMBING, LOW
VOLTAGE:
Cator Ruma & Associates,Co.
896 Tabor Street,
Lakewood, CO 80401-4700 303.232.6200
CIVIL:
Martin/Martin
225 Main Street,
Unit C101,
Edwards, CO 81632 970.926.6007
LANDSCAPE:
Lime Green Design, Inc.
900 East Louisiana Avenue,
Suite 209,
Denver, CO 80210 303.733.7558
STRUCTURAL:
Structural Consultants Inc.
3400 East Bayaud Avenue,
Suite 300,
Denver, CO 80209 303.399.5154
WINDOW SCHEDULE - BORROWED LITE
OPENING
NUMBER
OPENING
TYPE GLASS TYPE HEAD JAMB SILL FUNCTION Comments
BL 1038 W4 1/4" VISION FIXED
BL 3056A W7 1/4" VISION FIXED
BL 3056B W8 1/4" VISION FIXED
BL 3059A W10 1/4" VISION FIXED
BL 3059B W11 1/4" VISION FIXED
BL 4063A W12 VISION, LEAD
SHIELDED
LEAD SHIELDED RE.
SHIELDING REPORT
LEAD SHIELDED RE.
SHIELDING REPORT
LEAD SHIELDED RE.
SHIELDING REPORT
FIXED LEADED GLASS RE. SHIELDING REPORT. LEADED
GLASS WINDOW AND TELESCOPING FRAME (48"X36")
WITH VOICE PASSAGE BAFFLE FEATURE. BASIS OF
DESIGN: RAY BAR, TSVW-VP. REFER TO SHIELDING
PLAN FOR SHIELDING REQUREMENTS. ALUMINUM
CLEAR ANODIZED BRUSH GRAINED FINISH.
BL 4063B W13 VISION, LEAD
SHIELDED
LEAD SHIELDED RE.
SHIELDING REPORT
LEAD SHIELDED RE.
SHIELDING REPORT
LEAD SHIELDED RE.
SHIELDING REPORT
FIXED LEADED GLASS RE. SHIELDING REPORT. LEADED
GLASS WINDOW AND TELESCOPING FRAME (48"X36")
WITH VOICE PASSAGE BAFFLE FEATURE. BASIS OF
DESIGN: RAY BAR, TSVW-VP. REFER TO SHIELDING
PLAN FOR SHIELDING REQUREMENTS. ALUMINUM
CLEAR ANODIZED BRUSH GRAINED FINISH.
BL 4105 W14 1/4" VISION FIXED
FF
FF
FF
1 1/2" = 1'-0"
BORROWED LITE WINDOW FRAME DETAILS
STOREFRONT H.M
H.M H.M H.M
H.M
H.M H.M
BL 1038 - SECTION DETAIL
1 1/2" = 1'-0"
01
BL1038 - CORNER DETAIL
6
6
20
33
33
33
33
33
48
2 ADD #2 07.16.2015
5 ADD #5 TOV, DFPC 10.20.2015
6 ADD #6 TOV, DFPC 11.16.2015
20 ASI #12 02.03.2016
30 ASI #21 04.25.2016
33 ASI #24 05.20.2016
48 ASI #37 07.27.2016
48
01/04/17