PRE-OP / STAGE II
PACU
19 SEATS
26 UNITS - STACKED 15"X18"
62 UNITS - STACKED. 15"X18"
REDLINE
REDLINE
REDLINE
REDLINE
6'-6"
A B
A B
MATCHLINE
MATCHLINE
STORAGE
3063
HSKP
3057
1 - PATIENT
3023
2 - PATIENT
3022
3 - PATIENT
3021
4 - PATIENT
3020
5 - PATIENT
3019
6 - PATIENT
3018
7 - PATIENT
3017
8 - PATIENT
3016
9 -
PATIENT/PSP
3015
BAY 3 - FLEX
3032
CLEAN
SUPPLY
3027
PAT. TLT
3013
EQUIP.
STORAGE
3011
CONSULTATION
3003
PATIENT TLT
3028
PORTABLE
X-RAY
ALCOVE
3007
PATIENT TLT
3009
ALCOVE
NURSE
STATION
3029
MEDS
3026
SPECIMEN
FREEZER
3062
NOURISHMENT
CRASH CART
ALCOVE
STAFF TLT
3025
3-COR-8
BAY 1 - FLEX
3030
BAY 2 - FLEX
3031
BAY 4
3038
BAY 5
3037
BAY 6
3036
BAY 7
3035
BAY 8
3034
TLT/SHWR
3041A
STERILE
EQUIPMENTSTORAGE
3040
WOMEN'S
LOCKERS
3042
STAFF
LOUNGE
3043
CONFERENCE
3046
OFFICE
3048
OFFICE
3049
3-COR-9
OFFICE
3050
OFFICE
3051
TLT / SHWR
3042A
3-COR-7
OFFICE
3044
OR STAFF
EDUCATOR
3045
CLEAN ANTE
ROOM
3061
VESTIBULE
3052
OFFICE
3059
BREAK DOWN
3058
NON-STERILE
VENDORS
3053
STERILE
SUPPLIES /
CASE CARTS
3071
SPD - DIRTY
SIDE
3054
SPD - CLEAN
SIDE
3060
FAMILY TLT
3002
I.T.
3004
CONTROL /
SCHEDULER
3064
SURGERY
LOCKERS
WOMEN'S
3079
TLT/SHWR
3078A
SURGERY
LOCKERS
MEN'S
3078
ANESTHESIA
WORKROOM
3065
SCOPE
CLEANING
3056
ALCOVE
3055
ELECTRICAL
3008
STORAGE
ALCOVE
TLT/SHWR
3079A
WAITING
3001
HANGING
VEST
STORAGE
3080
STAFF TLT
3006
Aa
A
4.5
OFFICE
3005
3-COR-1
5
A223.1A
GREETER
ALCOVE
STORAGE
ALCOVE
MEN'S
LOCKERS
3041
TLT/SHWR
3042B
2
A221.1A
2
A300.1A
13
A226.1A
A.4
15
A227.1A
16
A227.1A
17
A228.1A
19
A229.1A
3
A222.1A
2
A301.1A
6
A224.1A
10
A225.1A
18
A228.1A
1
A200.1A
1
A200.1A
2
A200.1A
2
A200.1A
2.4 2.7
1.1
NURSE
STATION
3024
1.6
Aa.1
SOILED
HOLDING
3012
3-COR-3
3-COR-5
3-COR-4
3-COR-6
3-COR-2
HSKP
3010
14
A227.1A
11
A225.1A
12
A226.1A
9
A225.1A
8
A224.1A
7
A224.1A
1
A300.1A
20
A230.1A
21
A230.1A
1
A302.1A
1
A301.1A
1
A220.1A
4
A223.1A
ELEC CLOSET
3039
326 327 328
330 331
333 334 335
302
303 304 305 306 307
308
332
329
325
324
323
313
312 311
321
322
309
10
A202.1A
10
A202.1A
16
A501.1A
3
A202.1A
3
A202.1A
8
A202.1A
8
A202.1A
9
A202.1A
9
A202.1A
25'-11 1/2" 26'-0" 26'-0" 11'-2" 13'-9 1/2" 10'-0 1/2" 24'-11 1/2" 24'-11 1/2"
5'-0" 2'-11" 5'-0" 2'-11" 5'-0" 4'-8" 5'-0" 2'-11" 5'-0" 2'-11" 5'-0"
13'-6 1/2" 2'-8 7/8"
3'-8 1/4" 5'-0" 3'-5 3/8" 5'-0" 3'-5 3/8" 5'-0" 3'-2 3/8" 34'-11 7/8" 7'-9 3/4" 21'-4 3/4"
9'-8"
25'-0" 25'-0" 25'-0" 24'-11 1/2" 10'-0" 20'-0" 4'-11 1/2" 13'-3 1/2" 6'-8 1/2" 12'-3" 6'-0" 5'-7 3/8" 19'-7 3/8" 12'-3"
12'-5"
4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 6'-8" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 1'-8" 4'-0" 2'-8" 4'-0" 4'-0" 4'-0" 9'-4"
4'-0"
3'-10 3/4"
5'-9" 4'-0" 2'-8" 4'-0" 2'-8" 4'-0" 4'-3 3/8"
27'-4 3/8"
2'-9 3/8"
8'-2 3/8"
4'-10" 5'-0" 2'-5"
TO GRID
1'-5 3/8"
3005
3003A
3008
3011
3070A
3063
3-COR-6
3023
3010
3027
3-COR-7
201BB
3-COR-3
3028 3003 3009
3025
3013
3042
3-COR-9
3-COR-8
3046
3048
3049
3050
3051
3041
3043
3042A
3045
3061
3057
3052
3052A
3058
3058A
3079B
3078A
3079C
3061A
3056
3074B
3079A
3078B
3004
3002
3006
3-COR-1
3065
3042B
3041A
3059
3060
3016
3012
3039
3-COR-2
B243
3-COR-14
3-COR-1A
3021
10 - PATIENT/
PSP
3014
76'-11"
TO GRID
2'-5 7/8"
TO GRID 2'-5 7/8"
6'-0" 7'-4" 6'-0" 4'-8" 5'-0" 2'-0 1/2" 6'-0" 2'-0 1/2" 5'-0" 4'-8" 6'-0" 7'-4 1/8" 6'-0" 4'-5" 6'-10 1/2"
TO GRID
1'-7"
TO GRID
3'-10 3/4"
TO GRID
8'-10"
TO GRID
1'-8 5/8"
TO GRID
4'-11 1/2"
TO GRID 2'-1 1/4"
TO GRID
1'-7"
TYP.
1'-5 1/8" 1'-9 3/8"
1'-3 1/4"
TYP.
11 7/8"
TYP.
11 7/8"
TYP.
2'-6"
TYP.
1'-10"
310
314
315
316
317
318
319 320
1.5
F.4
TO GRID 1'-4 3/8" TO GRID
1'-3 7/8" TO GRID
5'-6 7/8"
TO GRID
7"
3'-9 1/8" 5'-0" 3'-3 1/8" 5'-0" 3'-3 1/8" 5'-0"
1'-4"
4'-8"
TO GRID
1'-10"
4'-8" 7'-9"
OFFICE
ASSISTANT
3047
G1
A302.1A
2 SIM
6'-6 1/4"1'-11 1/8"
A503.1A
9
26'-7 3/8" 55'-8" 7'-9"
92'-11 3/4"
A300.1A
4 SIM
A301.1A
3 SIM
1'-2 7/8"
1'-9 7/8" 7'-9" 5'-10 5/8" 10'-6"
9'-6 7/8" 39'-7 3/8"
2'-9 1/2"
8 7/8"
A501.1A
5 OPP
A501.1A
18
Aaa
3-COR-8E
3044 3040
VEST.
3070
3070
STEAM
STERILIZER
ENCLOSURE
3074B
OR(E)
SUB-STERILE
(E) SCRUB (E)
OR(E)
SOILED
UTILITY(E)
SURGERY
SUPPORT(E)
OR( E)
SCRUB(E) SUB-STERILE(E)
OR(E)
EVS (E)
SURGERY
SUPPORT(E)
SURGERY
SUPPORT(E)
3-COR-8E 3-COR-10E
3-COR-9E
OFFICE (E)
3053
STORAGE (E)
HALL
BL
3056A
BL
3056B
BL
3059A
BL
3059B
7'-7"
21'-11 3/4"
12'-4" 44'-6" 5'-2 1/2"
8'-0"
27'-1 1/2" 5'-0" 21'-2" 6'-0"
2'-0 1/4" 6'-3 1/2"
1'-1 3/4"
7'-9 3/4" 5" 9'-3 3/4" 6'-0 1/2"
1'-1 3/4" 8'-3 3/4" 5'-1 1/4" 2'-9" 5'-11 3/4" 7'-5" 3'-7" 6'-7" 8'-9 1/2"
4'-0" 22'-9" 1'-7 1/4" 5'-11 3/4"
13'-8 1/4" 12'-3 3/4" 11'-5 1/4"
12'-2" 12'-3 1/4" 11'-10 1/4" 12'-0" 12'-0 1/2"
2'-10" 8'-0" 9" 5'-4 1/4" 7'-2 1/2" 18'-1" 7'-9 1/4"
HOLD
8'-1" 5'-5 1/4" 2'-9" 9'-3 1/2" 10'-1" 12'-7" 4'-7 1/4" 8'-0" 2'-9 1/4"
CARTWASH RECESSED PIT, RE
STRUCTURAL AND EQUIPMENT
17'-5 1/4" 2'-3" 2'-0 1/2" 22'-10 1/4" 2'-0 1/4" 8'-2 1/2"
33'-2 3/4" 8'-2 1/2"
2'-1"
12'-8 3/4"
6'-11" 6'-10" 1'-3"
2'-10"
8'-0" 5" 8'-0" 2'-10" 13'-8 1/2" 11'-8 1/4" 11'-5 3/4"
13'-1 1/2"
9'-5"
HOLD
8'-1"
HOLD
8'-1"
7'-2 1/2" 9'-4 3/4"
HOLD 8'-0"
ALIGN
8" 21'-7 3/4"
7'-5"
15'-4 1/4"
R 10' - 10"
5'-8"
18'-0 1/2"
2'-5 1/4" 8'-0 1/2" 6'-5 1/2" 6'-0 3/4"
5'-7 1/4"
VIF
9'-3 1/4"
14'-11" 11'-8"
6'-0"
7'-11 1/2"
2'-2 1/2" 16'-5 3/4"
5'-0" 19'-6 3/4"
7'-4"
6'-1 3/4"
ALIGN
8'-11 3/4"
3'-0"
23'-11" 14'-9 1/4" 7'-3" 17'-7 1/4" 5'-0" 9'-3 3/4"
12'-7 3/4"
7'-4 3/4" 13'-3" 7'-6 1/4"
7'-4 1/4" 8'-4" 10'-1 1/2" 7'-0"
16'-10"
10'-1"
9'-9"
10'-9 1/4" 8'-0" 8'-9"
2'-10 3/4" 4'-10 1/2" 12'-6 3/4" 11'-7 1/2" 10'-11 3/4"
5'-0"
6'-0"
10'-6 1/2"
5'-0"
10'-11 1/2"
4'-0" 11'-2" 8'-0" 12'-11" 7'-7 1/4"
11'-9 1/4"
5'-8"
10'-0" 21'-3" 9'-10"
1'-7"
1'-4 3/4"
3'-11"
6'-0" FLOOR DRAIN, RE: PLUMBING AND
EQUIPMENT PLANS
1'-8 1/2"
7'-3 1/4"
2'-1" 9'-9 1/4" 2'-0" 11'-9"
21'-5 1/4" 1'-8 1/2"
3'-0" 5'-6" 6'-1" 7'-8"
8'-1 1/4"
10'-8 1/2"
8'-1 1/4"
15'-7 1/4"
9'-6 1/2"
GYP BD. BULKHEAD
OVER EQUIP
HOLD
10'-10" 0"2'-5"0" 10'-10"
1'-4"2'-10" 8'-0" 2'-5" 8'-0" 2'-10"
3020 3019 3018 3017
3015
3014
3022
20
3-COR-2
3-COR-2B
G.5
2.3
3026
21
21
21
21
21
21 21
21
21
21
21
21
21
21
21 21 21
21
3'-4"
12
ELEV 7
ELEV 8
G.7
STAIR A
STAIR C
STAIR B
ELEV 5
ELEV 4
ELEV 3
8'-1"
11'-3 5/8" 8'-0" 9'-0 1/2"
11'-3"
11'-3" 11'-3" 11'-3" 1'-7 1/4" 11'-5 1/4" 8'-0" 9'-0"
2'-2 1/2" 8'-0" 4'-9 3/4" 4'-9"
11'-8 3/4" 1'-0"
1'-0"
11'-0 3/8"
11'-0 3/8"
2'-0" 1'-2" 2'-6"
2'-6"
2'-8"
2'-6"
2'-2 5/8"
2'-2 5/8"
10"
6'-0" 19'-8" HOLD
8'-1"
15'-9"
1'-0" 10'-6 1/4"
4'-3 1/2"
A613.1A
21
11'-8" REDLINE
4'-8 1/4"
HOLD
10'-2" 4'-0"
6'-4"
1'-0 1/2"
2'-3"
15
15
15
15
15
23
1'-10" 20'-10 1/2"
8'-10 1/2"
24
24
24 24
24
6 33
6
6
6 33
6
33
6
6
33
6
33 6
33
6
33
6
33
6
33
6
33
6 33
66
33
6
33
MIN
10'-8"
11'-11"
26
3080
3062
3-COR-15
3'-4"
33
32
7'-4" 3'-9"
23
33
33
2'-9 1/2"
8'-6"
2'-7" 2'-3"
3'-7" 5'-1"
4'-6" 4'-0 1/4"
10'-1 1/2"
10'-1 1/2"
3'-5 3/4"
3'-1"
3'-1"
3'-4"
33
3'-4"
33
3'-1" 3'-4"
33 3'-1"
33
33
3'-1"
3'-4"
33
33
33
33
5'-2 3/4"
7'-3"
33
1'-10"
33
33
33
1'-9 3/4" 37
37
37
4'-5"
37
A B C
D
E
GENERAL NOTES:
1. ALL DIMENSIONS ARE GIVEN TO FINISHED FACE OF SURFACES, CENTERLINES OF
DOUBLE DOORS, INTERIOR WINDOWS AND FIXTURES, OR HINGE SIDE OF SINGLE
DOORS, U.N.O.
3. WHEN TWO DIFFERENT PARTITION TYPES APPEAR ADJACENT TO EACH OTHER,
THEIR FINISHED WALL SURFACES MUST ALIGN UNLESS OTHERWISE NOTED.
4. PARTITION TYPE DESIGNATION SHALL BE CONTINUOUS UNTIL NOTED OTHERWISE;
CHANGES OCCUR AT WALL INTERSECTIONS AND/ORSTRUCTURAL ELEMENTS.
5. WHERE A RATED PARTITION IS INDICATED AND WHERE A RATING HAS BEEN GIVEN TO A
FLOOR/DECK ALL PENETRATIONS MUST BE PROPERLY FIRE/SMOKE SEALED WITH A U.L.
RATED FIRE STOPPING ASSEMBLY PER THE ASSIGNED RATING REQUIREMENTS.
6. AT ALL COLUMNS SHOWN FURRED OUT, USE PARTITION TYPE C-- UNLESS OTHERWISE
NOTED.
7. FOR CURVED/ARCHED WALLS PROVIDE STUD FRAMING PER UNITED STATES GYPSUM
(USG) RECOMMENDATIONS PER GYPSUM BOARD THICKNESS.
8. REFER TO LIFE SAFETY PLANS FOR GENERAL SMOKE AND/OR FIRE RATING
INFORMATION AND SPECIAL STRUCTURAL FIRE PROOFING AREAS.
9. REFER TO "FIRE RESISTANCE DESIGN MANUAL," LATEST EDITION PUBLISHED BY THE
GYPSUM ASSOCIATION FOR ADDITIONAL INFORMATION. THE DESIGN MANUAL'S
GENERAL EXPLANATORY NOTES PERMIT MODIFICATIONS AND SUBSTITUTIONS
WITHOUT DEGRADING THE FIRE RESISTANT RATING, RESULTING FROM INCREASING
STUD DEPTHS, STUD GAUGES, WALLBOARD THICKNESS, NUMBER OF LAYERS, AND
CHASE WALL DIMENSIONS.
10. AT ALL STRUCTURAL STUD FRAMED EXTERIOR WALL CONDITIONS, INTERIOR FINISH
GYP SHALL EXTEND CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE AND SEALED
SMOKE TIGHT AT ALL LEVELS.
11. USE DIRECT ATTACHED SYSTEMS FOR UL TESTED FIRE RATED WALLBOARD SYSTEMS.
2. REFER TO THE LIFE SAFETY PLANS SHEETS AND FLOOR TAG PLAN SHEETS FOR
PARTITION TYPE LOCATIONS. ALL NEW WALLS TO BE TYPE A - A UNLESS OTHERWISE
NOTED.
12. WATER RESISTANT GYPSUM BOARD SHALL BE USED IN LIEU OF STANDARD
GYPSUM BOARD AT WALLS WITH TILE OR STONE VENEER FINISH. AT WET WALLS
USE CEMENTITIOUS BACKER IN LIEU OF STANDARD GYPSUM BOARD.
13. PROVIDE BLOCKING AND SUPPORT FOR ALL WALL MOUNTED EQUIPMENT AND
ACCESSORIES.
14. AT ALL INTERIOR DOOR FRAMES AND CASED OPENINGS 48" WIDE OR LESS PROVIDE
(2) 20 GA STUDS FULL HEIGHT TO STRUCTURE EACH SIDE. AT ALL DOOR FRAMES
AND CASED OPENINGS LARGER THAN 48" WIDE AND ALL LEAD LINED DOORS
PROVIDE (2) 16 GA STUDS EACHSIDE WITH 16 GA FRAMED BOX HEADER.
15. PATCH EXISTING FIRE PROOFING AS REQUIRED TO CONFORM TO FIRE RATING
REQUIREMENTS. VERIFY EXTENT OF PATCHING.
16. AT LEVEL 4 EXTERIOR WALL PLATFORM FRAMED STRUCT. STL. STUDS, PROVIDE
SHOP DRAWING/SUBMITTALS ON STUD LAYOUT IN ORDER TO COORDINATE WITH
KNIGHT SYSTEM AND FIBER CEMENT BOARD SYSTEM LAYOUT. PROVIDE DOUBLE
STUDS AT ALL INSIDE AND OUTSIDE CORNERS.
17. PATCH AND REPAIR TO MATCH EXISTING WALLS, FLOORS, AND CEILINGS DUE TO
INSTALLATION OF MEP & IT SYSTEMS ABOVE.
18. DOOR ASSEMBLIES IN INTERIOR PARTIONS ARE 6" FROM FINISHED FACE OF
ADJACENT PERPENDICULAR PARTITION TO EDGE OF DOOR LEAF, UNLESS NOTED
OTHERWISE.
KEYNOTE:
1. TOOTH-IN BRICK AT DEMOLISHED CURTAINWALL OPENING. AT EXPOSED EXTERIOR
SPACE BETWEEN 1 STOREY ADDITION AT LEVEL 1 AND LEVEL 3 ADDITION EXTEND
BRICK FROM CONCRETE ROOF DECK AT LEVEL 1 ROOF TO 1'-0" ABOVE EXTERIOR
SOFFIT. REFERENCE TAG PLANS AND SHEET A301.1A FOR ADDITIONAL PARTITION
INFORMATION.
3. TIE-OFF. INSULATED WALL MOUNTED TIE-OFF BY TRACTEL WELDED TO STEEL PLATE
PROVIDED BY STRUCUTRAL, RE:20/S305. WELDED CONNECTION DESIGN BY TRACTEL.
4. WALKWAY PAVERS
5. ABOVE EXISTING STOREFRONT SYSTEM, PROVIDE STUCCO ON MTL. LATH, ON ASPHALT
IMPREGNATED PAPER ON 5/8" SHEATHING, ON 7/8" FURRING CHANNELS, 16" O.C. FROM
WINDOW HEAD TO 6" ABOVE SOFFIT. REFER TO WALL SECTIONS
6. WINDOW SILL.
2. STUCCO PILASTER ON 6" HIGH CONC. BASE. PROVIDE STUCCO, ON METAL LATH, ON
SLIP SHEET, ON RIGID INSULATION/WEATHER BARRIER, ON 5/8" SHEATHING, ON 3 5/8"
MTL. STUDS.
7. PROVIDE CONT. 3 1/2 RIVER ROCK IN RIVER TYPE PATTERN. RIVER PATTERN TO BE
DARKER ROCK.
8.
9. MOVEABLE PARTITION
10. MIRRORS
11. WALL MOUNTED GYM EQUIPMENT PROVIDE IN WALL BLOCKING FULL LENGTH AND
WIDTH OF WALL
12. RELOCATED EXISTING CASEWORK AND/OR PLUMBING FIXTURE
13. PROVIDE NEW FLOOR SLAB TO MATCH EXISTING WHERE DEMOLISHED.
14. 18"x18"x18" SUMP PIT WITH REMOVABLE COVER. COVER MUST WITHSTAND 1500 POUNDS
MINIMUM
15. 4" CMU INFILL. ALIGN WITH OUTSIDE FACE OF EXISTING CONCRETE WALL.
16. PROVIDE ACCESS DOOR AT EXISTING OPENING, FIELD VERIFY OPENING HEIGHT.
PROVIDE 4"
CMU INFILL TO ESTABLISH 3'- 4" ROUGH OPENING. ALIGN WITH OUTSIDE
FACE OF EXISTING CONCRETE WALL.
17. REMOVE EXISTING GLAZING. INSTALL/REPLACE WITH SPANDREL GLASS.
18. PROVIDE FURRING/BLOCKING BETWEEN NEW STUD AND WINDOW MULLION. SCRIBE
GYPSUM BD TO AND ALIGN WITH OUTER EDGE OF VERTICAL MULLION.
19. PROVIDE OPAQUE FILM OVER EXISTING GLAZING ON WEST SIDE OF GLASS.
20 PATCH AND REPAIR STAIR LANDING AS REQUIRED.
INFILL OPENING TO MATCH EXISTING ADJACENT WALL. MATCH ADJACENT BASE.
21 CEILING MOUNTED CUBICLE CURTAIN TRACK (CCT)
22 SHOWER CURTAIN ROD
23 PATCH AND REPAIR WALL AND OR BULKHEAD AS REQUIRED.
24 PLAM SHELF AND HANG ROD
25 PROVIDE METAL STUD WITH BATT INSULATION AND (1) LAYER TYPE X GYPSUM BOARD
INFILL PARALLEL TO 4" CMU INFILL AT DOOR HEAD. ALIGN WITH INTERIOR FACE OF
CONCRETE WALL AND RETURN TO 4" CMU AT HEAD. INSTALL NEW DOOR AND FRAME.
26 PROVIDE NEW DOOR AND FRAME. COORDINATE LOCATION WITH
MECHANICAL CONTRACTOR.
27 24"x24" DEEP SUMP PIT
28 2" CONCRETE WALKWAY PAVERS WITH SLIP SHEET.
29 2HR REMOVABLE PANEL FOR COIL PULL.
30 ALIGN FACE OF SHAFT WALL WITH FACE OF LANDING. RETURN STAIR
KNEE- WALL TO SHAFT WALL AND ALIGN.
REMOVE EXISTING SPANDREL GLAZING. INSTALL/REPLACE WITH
VISION GLASS.
31
PLAM SOFFIT (TO UNDERSIDE OF CEILING) ABOVE WARDROBE AND
FILLER PANELS, MATCH ADJACENT COLOR
32
000 4' 8' 16'
SCALE:
N
This document is the property of Heery International, Inc. and Heery International Inc. retains all
rights therein, including copyrights. It may only be used in a manner consistent with Heery
International Inc.'s rights while Heery International, Inc. is providing services for the specific project
identified or referred to herein or extensions thereto. It may not be used for any other purpose
except with the express written agreement of, and compensation to, Heery International Inc.
Copyright © 2013 by Heery International, Inc. all rights reserved.
WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42"
drawn by checked by
sheet number
sheet title
item date
date
issued for
seal/signature
consultants/construction managers
owner's project number
project number
1/8" = 1'-0"
Heery International
555 17th Street, Suite 500
Denver, CO 80202
720.946.0276
OWNER'S PROJECT NUMBER
TOV:
C&S PRJ14-0157 B15-0185 (ADD#5)
TI PRJ14-0157 B15-0461 E15-0043 (ADD#6)
DFPC:
C&S 9667 (ADD#5)
TI TBD
6/15/2016
2:43:19 PM
A103A.1A
Checker
Author
FLOOR PLAN - LEVEL
THREE - ZONE A
02/06/2016
CONSTRUCTION
DOCUMENTS
VAIL VALLEY
MEDICAL CENTER
PHASE 1 - WEST WING
181 WEST MEADOW DRIVE
VAIL, CO
HII-1302604
INTERIOR DESIGN:
Gallun Snow
1920 Market Street,
Suite 240,
Denver, CO 80202 720.407.6002
MECHANICAL, ELECTRICAL,PLUMBING, LOW
VOLTAGE:
Cator Ruma & Associates,Co.
896 Tabor Street,
Lakewood, CO 80401-4700 303.232.6200
CIVIL:
Martin/Martin
225 Main Street,
Unit C101,
Edwards, CO 81632 970.926.6007
LANDSCAPE:
Lime Green Design, Inc.
900 East Louisiana Avenue,
Suite 209,
Denver, CO 80210 303.733.7558
STRUCTURAL:
Structural Consultants Inc.
3400 East Bayaud Avenue,
Suite 300,
Denver, CO 80209 303.399.5154
FLOOR PLAN - LEVEL THREE - ZONE A
N.T.S
KEY PLAN
SCALE: 1/8" = 1' - 0"
2 ADD #2 07.16.2015
5 ADD #5 TOV, DFPC 10.20.2015
6 ADD #6 TOV, DFPC 11.16.2015
15 ASI #7 12.22.2015
20 ASI #12 02.03.2016
23 ASI #15 TBD
24 ASI #16 02.03.2016
26 ASI #19 02.26.2016
32 ASI #23 04.08.2016
33 ASI #24 05.20.2016
37 ASI #28 06.15.2016
**Issued as a sketch in original ASI
**