Loading...
HomeMy WebLinkAboutA105A.1AUP UP UP H H H M M M MH H H H P P P P P 1 3 4 5 6 7 8 F E D C B G H J K H.3 A B A B MATCHLINE MATCHLINE J.2 Aa 4.5 5 A223.1A 2 A221.1A 13 A226.1A A.4 15 A227.1A 16 A227.1A 17 A228.1A 19 A229.1A 3 A222.1A 2 A301.1A 6 A224.1A 10 A225.1A 18 A228.1A G.4 2.4 2.7 H.1 1.6 Aa.1 14 A227.1A 11 A225.1A 12 A226.1A 9 A225.1A 8 A224.1A 7 A224.1A 20 A230.1A 21 A230.1A 1 A301.1A 1 A220.1A 4 A223.1A CANOPY BELOW 56'-8" 1'-2" MECHANICAL EQUIPMENT PAD 9" CONC. TOPPING ON STL. DECK RE: STRUCT. ROOF DRAIN AND OVERFLOW DRAIN, TYP. RE: PLUMBING STAIRS AND LANDING TO AHU ENCLOSURE RE: STRUCT. STAIRS AND LANDING TO AHU ENCLOSURE RE: STRUCT. MECHANICAL EQUIPMENT PAD 9" CONC. TOPPING ON STL. DECK RE: STRUCT. STAIRS AND LANDING TO AHU PLATFORM RE: STRUCT. 54'-2" 27'-10" 3'-10 1/2" 37'-5 1/2" 11'-2" 8'-1 1/2" 3'-10 1/2" 3'-3" 4'-5" 2'-1 1/2" 18'-6" 23'-6" 33'-10" 10'-6" 3'-8" MECH. SCREEN W/ WEATHERIZED METAL PANEL SYSTEM FASTENED TO GALV. MTL. STUDS ON POST FASTENED TO STRUCTURAL BEAM. DETAIL 7/500.1A TIE-OFF POST ANCHORED TO ROOF, TYP. RE: STRUCT. POST FOR DAVIT SYSTEM ANCHORED TO ROOF, TYP. RE: STRUCT. ALIGN CENTER OF ANCHORS WITH EDGE OF WINDOW CANOPY TIE-OFF POST TIE-OFF POST TIE-OFF POST DAVIT SYSTEM POST DAVIT SYSTEM POST DAVIT SYSTEM POST 6'-0" 2'-3 1/2" 3'-4 7/8" 45° TIE-OFF POST DAVIT SYSTEM POST 6'-0" DAVIT SYSTEM POST 1'-11" 1'-7 7/8" TIE-OFF POST DAVIT SYSTEM POST MECH. SCREEN /STUCCO SYSTEM, ALIGN FACE WITH EXTERIOR FACE OF ADJACENT MECH SHAFT, DETAIL 19/A501.1B 7'-8 3/8" MANSARD ROOF STANDING SEAM MTL. ROOF ON EXT. SHEATHING ON 3" MTL. DECKING ON STL. FRAMING RE: STRUCT. CONTINUOUS 6"x6" GUTTER AT PERIMETER OF MANSARD ROOF W/ HEAT TRACE MANSARD ROOF STANDING SEAM MTL. ROOF ON EXT. SHEATHING ON 3" MTL. DECKING ON STL. FRAMING RE: STRUCT. TIE-OFF POST DAVIT TIE-OFF TO MECHANICAL SCREEN DAVIT SYSTEM POST 8'-0 7/8" 2'-0" 37'-10 3/4" 5'-0" CHILLER RE: MECH. MECH. EQUIP. SCREEN - FIBER CEMENT BOARD ON MTL. DECK-DETAIL 6/A502.A1 WINDOW CANOPY DETAIL RE:___ 20'-1 1/4" 6'-0" 2'-3 1/2" 18'-0" 4'-0" 6'-0" 1'-2" 2'-7 1/8" 6'-0" 45° 45° WINDOW CANOPY WINDOW CANOPY 12'-2 3/8" 26'-6" 9'-5 1/2" AIR HANDLING UNIT MECHANICAL PENTHOUSE 7'-11 7/8" MECHANICAL PENTHOUSE AIR HANDLING UNIT RIDGE 10" INSUL. TYP. RIDGE 1'-1" INSUL. 1'-3" INSUL. 1'-2" INSUL. VERT. LADDER, SEE DETAIL 5/A302.1A ROOF OF EXIST. BLDG. BELOW RIDGE 1'-1" INSUL. . . 10" INSUL. RIDGE10" INSUL.. . 10" INSUL. RIDGE 10" INSUL. . . 10" INSUL. 10" INSUL. 1'-1" INSUL. ROOF TOP FANS, RE: MECH. (TYP.) RIDGE1'-1" INSUL. .R.D. O.D. 10" INSUL. AHU MECH. PENTHOUSE R.D. O.D. R.D. O.D. 1'-1" INSUL. AT DOOR SILL 1'-1" INSUL. R.D. O.D. 4" INSUL. MIN. AT DRAINS ROOF TOP FAN RE: MECH. (TYP.) R.D. O.D. 10" INSUL. 10" INSUL. R.D. O.D. SLOPE 1/4" PER 1'-0" MIN. 10" INSUL. RIDGE 1'-1" INSUL. TYP. 11" INSUL. 1'-0" INSUL. 1'-3" INSUL. 1'-3" INSUL. ALIGN STUCCO ON SHAFT W/ STUCCO ON MECH. EQ. SCREEN RIDGE 1'-3" INSUL. VEST. ROOF BELOW CONT. MTL. ROOF EDGE R.D. O.D. RIDGE 10" INSUL. TYP. ROOF TOP FANS RE: MECH. (TYP.) VERT. LADDER, SEE 5/A302.1A R.D. O.D. 10" INSUL. RIDGE 1'-2" INSUL. R.D. O.D. RIDGE 10" INSUL. 1'-1" INSUL. 6'-0" R.D. O.D. 10" INSUL. COVER EDGE OF CONC. W/ TAPERED INSUL. TO MATCH ADJOINING SLOPE OF ROOF, TYP. RIDGE 12" INSUL. RIDGE 10" INSUL. ALIGN FACE OF MTL. PANEL ON MECH. SCREEN W/ MTL. PANEL ON SHAFT ENCLOSURE MTL. COPING 6"x6" MTL. GUTTER W/ HEAT TRACE ROOF WALKWAY 2' x 2' EPDM PADS, TYP. VERT. LADDER, SEE DETAIL X SCUPPER W/ SPLASH BLOCK BELOW 1.5 F.4 SPLASH BLOCK SPLASH BLOCK CONT. MTL. ROOF EDGE 10" INSUL. 10" INSUL. 1'-0" INSUL. 3" 10" INSUL. 10" INSUL. RIDGE 10" INSUL. 11" / 1'-0" 10" INSUL. SCUPPER W/ SPLASH BLOCK BELOW WALKWAY PADS RE: SPECS A302.1A 4 TIE-OFF POST TIE-OFF POST G1 Aaa 3 A105A.1A 5'-0" 12'-0" 2'-10 3/4" STAIR C 3 A105A.1A SIM 3 A105A.1A SIM 2 4'-0" 4'-10" ROOF DRAIN TYP. ROOF DRAIN TYP. ROOF DRAIN TYP. DOWNSPOUT TYP. DOWNSPOUT TYP. 4'-0" A B C D E CONT. MTL ROOF EDGE SCUPPER SPLASH BLOCK VERTICAL LADDER SCUPPER SPLASH BLOCK VERTICAL LADDER SEE DETAIL 5/A302.A TIE-OFF POST TIE-OFF POST 2 DUCTS TO CLEAR ROOFING BY 2'-0" TO ALLOW FOR FUTURE REAPAIR @ ROOF ROOF PLAN GENERAL NOTES 1. 2" DIA GALVANIZED PIPE FRAME GALVANIZED LANDING OPEN STL. GRATING GALVANIZED HANDRAIL GALVANIZED STL. STRINGER GALVANIZED METAL STAIR TREAD, OPEN STL GRATING GALVANIZED STAIR FOOTING ROOF MEMBRAIN RUBBER MEMBRAIN PROTECTION PADS FLEXIBLE ROOF FLASHING (4) CORNERS @ LANDING PENETRATE ROOF DECK 4'-0" 3'-6" 3'-6" VARIES 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/19/2015 5:32:37 PM A105A.1A Checker Author ROOF PLAN - LEVEL FIVE - ZONE A MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 ROOF PLAN - LEVEL FIVE - ZONE A SCALE: 1/8" = 1' - 0" KEY PLAN N.T.S 2 ADDENDUM # 2 07.16.2015 1/4" = 1'-0" 3 TYP. STAIR @ ROOF TOP MECH. UNIT 2 6-2-2015 07.16.2015 08/11/15