Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A200.1A
LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 1 2 3 4 5 6 7 8 4.5 1.1 1.6 0.7 7 A500.1A 12 A500.1A 9 A503.1A 13 A503.1B 1.5 3 A503.1A 4 A503.1A 5 A503.1A 6 A503.1A 12 A503.1B T.O STL. @ ELEVATOR 166' - 9" 24 A503.1C WEATHERED METAL PANEL TO MATCH EXISTING EXISTING WEATHERED MTL PANEL TO REMAIN WEATHERED METAL PANEL TO MATCH EXISTING HARDIE PANEL SYSTEM DARK BRONZE ALUM. ENCLOSURE ADHERED NATURAL STONE VENEER DARK BRONZE ALUM. STOREFRONT SYSTEM OFF-RED STUCCO TO MATCH EXISTING CENTRAL BUILDING APPLIED TO EXIST. CONC. SPANDREL EXISTING MTL MANSARD ROOF TO REMAIN EXISTING CONCRETE TO REMAIN EXISTING WINDOW & METAL PANEL SYSTEM TO REMAIN ADHERED NATURAL STONE VENEER BEYOND WEATHERED METAL PANEL TO MATCH EXISTING WEATHERED METAL PANEL BROW MTL. MANSARD ROOF TO MATCH EXISTING CENTRAL BUILDING TAN STUCCO TO MATCH EXISTING CENTRAL BUILDING ADHERED NATURAL STONE VENEER DARK BRONZE ALUM STOREFRONT SYSTEM WEATHERED METAL PANEL TO MATCH EXISTING ADHERED NATURAL STONE VENEER HARDIE PANEL SYSTEM TAN STUCCO BEYOND AT STAIR AND ELEVATOR EXTENSION STONE ELEMENTS STONE ELEMENTS TAN STUCCO BEYOND EXISTING WINDOW & METAL PANEL SYSTEM TO REMAIN WEATHERED METAL PANEL SCREEN WALL DARK BRONZE ALUM. CURTAIN WALL SYSTEM MECH SHAFT BEYOND CJ CJ CJ TYP CJ TYP CJ TYP. CJ CJ CJ CJ 3'-6" CJ SCREEN WALL BEYOND STONE ELEMENTS STONE ELEMENTS RED STUCCO ON EXISTING BRICK TAN STUCCO TO MATCH EXISTING CENTRAL BUILDING MTL GUTTER AND PIPE LEADER BOX ENCLOSURE EXISTING METAL PANEL EQ EQ ALIGN HORIZONTAL PANEL JOINTS WITH EXISTING ADJACENT WEATHERED METAL PANEL. 2.3 MECHANICAL VENT EQ EQ EQ EQ 8" 10" 10" 7 7/16" 5 5 15 A501.1A T.O.S. 163' - 5 1/2" 32 32 32 7 A132A.1A 8 A132A.1A 10 A132A.1A 10 A503.1A 37 47 47 47 47 47 47 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" F E D C B G H J K H.3 J.2 Aa A Aa.6 A.4 G.4 H.1 Aa.1 2 A502.1C 3 A502.1C 14 A501.1A 5 A502.1A 5 A501.1A OPP F.4 23 A503.1C 22 A503.1C WEATHERED STEEL PANEL TO MATCH EXISTING AT ELEVATOR SHAFT HARDIE PANEL SYSTEM ADHERED NATURAL STONE VENEER TAN STUCCO TO MATCH EXISTING CENTRAL BUILDING ADHERED NATURAL STONE VENEER MTL MANSARD ROOF TO MATCH EXISTING CENTRAL BUILDING EXISTING BRICK TO REMAIN STONE COLUMN BASE TYP. TAN STUCCO APPLIED TO EXISTING BRICK TO MATCH EXISTING CENTRAL BUILDING CANOPY ADHERED NATURAL STONE VENEER DARK BRONZE MTL ENCLOSURE ALUMINUM LOUVER TO MATCH TAN STUCCO COLOR REMOVE EXIST. BRICK AND APPLY WEATHERED MTL PANELS STONE SILL TAN STUCCO TO MATCH EXISTING CENTRAL BUILDING HARDIE PANEL SYSTEM MTL MANSARD ROOF TO MATCH EXISTING CENTRAL BUILDING WEATHERED MTL. PANEL TO MATCH EXISTING ASHLAR STONE TO MATCH EXISTING STONE HEAD & SILL/ TYPICAL TAN STUCCO APPLIED TO EXISTING BRICK TO MATCH EXISTING WEATHERED MTL. PANEL BROW WEATHERED MTL. PANEL BROW BEYOND MECH. SHAFT TAN STUCCO TO MATCH EXISTING CENTRAL BUILDING CJ CJ STONE ELEMENT CJ CJ CJ CJ CJ CJ REUSE EXISTING BRICK CJ CJ MTL GUTTER AND PIPE LEADER BOX ENCLOSURE STONE ELEMENTS DK BRONZE COLUMN ENCLOSURE CJ EXISTING METAL PANEL G1 Aaa MTL GUTTER AND PIPE LEADER BOX ENCLOSURE REUSE EXISTING BRICK 22 A501.1B SIM 5'-0" 17'-0" 5'-0" 7'-7" G.5 G.7 FIRE DEPARTMENT CONNECTION 8" 8" 6 1/4" EQ 7 7/8" 8" 8" EQ 5" 5 5 15 A501.1A 7 A501.1A 23 T.O.S. 163' - 5 1/2" 32 32 30 33 37 37 47 47 47 OFF-RED STOREFRONT TO MATCH EXISTING 47 000 4' 8' 16' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/27/2016 2:23:40 PM A200.1A Checker Author OVERALL BUILDING ELEVATIONS - SOUTH & WEST - C&S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/8" = 1'-0" 1 SOUTH BUILDING ELEVATION - ZONE A - C&S 1/8" = 1'-0" 2 C&S - WEST BUILDING ELEVATION - ZONE A NOTE: EXTERIOR STRUCTURAL STUD LAYOUT MUST BE COORDINATED WITH FIBER CEMENT BOARD VERTICAL PANEL SYSTEM JOINTS. PROVIDE SHOP DRAWINGS SIMULTANEOUSLY. 2 ADD #2 07.16.2015 5 ADD #5 TOV, DFPC 10.20.2015 23 ASI #15 TBD 30 ASI #21 04.25.2016 32 ASI #23 04.08.2016 33 ASI #24 05.20.2016 37 ASI #28 06.15.2016 47 ASI #35 06.27.2016 01/04/17