HomeMy WebLinkAboutA222.1AEXTERIOR WALL ASSEMBLIES LEGEND NOTE: REFER TO PLANS FOR DISTANCE FROM GRID TO STUDS MATERIALS WIDTH W1 - STUCCO GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 0 RIGID INSULATION/WEATHER BARRIER 2 INCHES ASPHALT IMPREGNATED CRAFT PAPER INCHES METAL LATH INCHES ASSEMBLY THICKNESS FT 10 0 INCHES W2 - STUCCO @ MECH. SHAFT STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES ASSEMBLY THICKNESS 0 FT 7 3/8 INCHES W3 - STONE VENEER GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 11 1/4 INCHES 5/8 INCHES 5/8 INCHES INCHES 1 INCHES 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES 3/4 METAL LATH INCHES 3/4 RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS # 15 FELT 0 W4 - STONE VENEER @ ELEVATOR SHAFT STUDS INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 1 FT 4 5/8 INCHES RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS #15 FELT 0 6 GYPSUM BOARD STUDS SHEATHING WEATHERED STEEL METAL PANEL ASSEMBLY THICKNESS Z-GIRTS W/ RIGID INSULATION/WEATHER BARRIER W5 - WEATHERED STEEL METAL PANEL ASSEMBLY 2 6 INCHES INCHES INCHES 1/4 W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM INCHES RIGID INSULATION/WEATHER BARRIER 2 3/4 INCHES INCHES FIBER CEMENT BOARD VERTICAL PANEL KNIGHT SYSTEM 1/2 ASSEMBLY THICKNESS 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING W7 - BRICK VENEER INCHES RIGID INSULATION/WEATHER BARRIER 2 INCHES BRICK VENEER (SALVAGED) 5/8 INCHES AIR SPACE 3/4 ASSEMBLY THICKNESS 1 FT 2 5/8 INCHES 3 1 0 0 0 0 0 INCHES MORTAR SCRATCH COAT 1/2" INCHES MORTAR SETTING BED 1/2" INCHES 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 1 MORTAR SCRATCH COAT MORTAR SETTING BED 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 0 INCHES 1/2" INCHES 1/2" INCHES 1 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" F G 1'-6" EXIST. CONCRETE STRUCT. EXIST. CONC. STRUCT. LOBBY VESTIBULE SPD - CLEAN SIDE PRACTICE DIRECTOR LOBBY RECEPTION HORIZONTAL DUCT SHAFT MECH. ROOM ALUM. STOREFRONT SYSTEM W/ ENTRY DOORS CONT. MTL. CONC. FOUND. WALL RE: STRUCT. CONCRETE PAVING RE. CIVIL W5 - WEATHERED STEEL METAL PANEL ASSEMBLY PROTECTION BOARD ON 2" RIGID INSUL. ON FLUID APPLIED WATER PROOFING CONC. FTG. RE: STRUCT. STL. BEAM RE: STRUCT. CLG. RE: FINISH SCHEDULE EXIST. MTL. PANEL ASSEMBLY, TO REMAIN EXIST. WINDOW, TO REMAIN EXIST. CONC. STRUCT. 3'-4" R3 - UL NO. P741, 2 HR R-1 - UL NO P741, 1 HR CLG. RE: FINISH SCHEDULE CONC. ON MTL. DECK RE: STRUCT. CLG. RE: FINISH SCHEDULE CONC. ON MTL. DECK RE: STRUCT. 3'-8" A501.1A 4 T.O. STEEL VESTIBULE 110' - 8" TERRACE T.O. STEEL TERRACE 112' - 11 1/2" 4'-1 1/2" CONT. WD BLOCKING STUCCO SOFFIT PRE-FINISHED 6" X 6" MTL. GUTTER W/ HEAT TRACE CONT. STUCCO 'V' REVEAL CONT. STUCCO 'V' REVEAL WINDOW GYP. BOARD COL. ENCLOSURE CONT. WD. BLOCKING CONC. FOUND. WALL RE. STRUCT. CONC. SLAB ON GRANULAR FILL RE: STRUCT. CONC. FTG. RE: STRUCT. EXIST. CONC. STRUCT. EXIST. CONC. SLAB STL. BEAM RE: STRUCT. CONC. ON MTL. DECK RE: STRUCT. 2" RIGID INSUL. TUNNEL LINING CONC. SLAB ON GRANULAR FILL RE: STRUCT. ROOF DRAIN ENCLOSED COL. W/ STONE VENEER ENCLOSURE, BEYOND TO 4" ABOVE BOTTOM OF SOFFIT 3 1/2" DIA. RIVER ROCK ROOF COVER R2 - UL NO. D949, 2HR PAINTED EXTERIOR GYPSUM BOARD SOFFIT. STUCCO FINISH ON EXIST. BRICK R30 BATT INSUL. 2'-10" WINDOW 2'-0" 6 1/2" 8" STAIR LANDING LEVEL 1 107' - 0" EXIST. CONC. FOUNDATION WALL 9'-0" 2'-0" STANDING SEAM MTL ROOF ON MFG UNDERLAYMENT ON 5/8" GYP SHEATHING, ON MTL DECK, RE: STRUCT MTL. DECK RE:STRUCT. GYP. BOARD COL. ENCLOSURE GYP. BOARD COL. ENCLOSURE 2'-5" W6 - FIBER CEMENT BOARD PANEL SYSTEM W1 – STUCCO A502.1A 1 A502.1A 3 A502.1A 4 A502.1A 2 A501.1A 3 A501.1A 6 A500.1A 3 A500.1A 1 A501.1A 7 F.4 A501.1A 19 4" A500.1A 8 6" 4" ADHERED NATURAL STONE VENEER SAN MIGUEL ON 5/8" GYP BD. 6" x 54 MIL. MTL. STUDS @ 16" O.C. , RE:STRUCT. JOINT AT ALL COLUMN FACES, TYPICAL 2" ADHERED NATURAL STONE VENEER CAP (COLORADO BUFF) OVERHANG FIELD STONE 1" ALL AROUND CONT. MTL. ROOF EDGE, LAPPED OVER PARAPET STANDING SEAM MTL ROOF ON MFG. UNDERLAYMENT ON 5/8" GYPSUM DECK ON MTL. DECK SHEATHING, RE: STRUCT STL. TRUSS RE: STRUCT R30 ROCKWOOL BATT INSUL. (2) ROWS OF SNOW FENCE 1'-10 1/2" 8'-4" 7'-3 1/2" PREFINISHED 25GA BRAKE MTL. COLLECTOR COVER G.5 A500.1A 15 3 1/2" 6 7/8" 1'-6" 4'-1 1/2" CONFERENCE ROOM 6" 23 23 6" A501.1B 1 20 20 20 20 SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401 JAMB BEYOND 3'-4" ROLLER SHADE 20 ROLLER SHADE 20 8' - 8" 9' - 1" 37 2 PEICE PREFINISHED BASE AND COUTER FLASHING EXTEND ROOF MEMBRANE 10" MINIMUM UP VERTICAL SURFACE 4'-8" 37 37 37 ROOF ASSEMBLIES LEGEND MATERIALS THICKNESS R1 - ROOF LEVEL 5, 6 - UL NO. P741, 1 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES R2 - ROOF LEVEL 2 - UL NO. D949, 2 HR RIGID POLYURETHANE INSULATION 5 INCHES VARIES TAPERED INSULATION MEMBRANE INCHES ASSEMBLY THICKNESS 0 FT 5 3/4 INCHES 1/4 3 1/2 1/4 3/8 0 CONCRETE DECK VARIES R3 - ROOF LEVEL 1 - UL NO. P741, 2 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES 3 1/2 1/4 3/8 0 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A BALLAST GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A 000 1' 2' 4' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/2" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/15/2016 2:44:12 PM A222.1A Checker Author WALL SECTIONS - C & S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/2" = 1'-0" 3 WALL SECTION @ 1 & F/G2 2 ADD #2 07.16.2015 4 ADD #4 09.21.2015 5 ADD #5 TOV, DFPC 10.20.2015 20 ASI #12 02.03.2016 23 ASI #15 TBD 37 ASI #28 06.15.2016 37 37 01/04/17