A223.1A
EXTERIOR WALL ASSEMBLIES LEGEND NOTE: REFER TO PLANS FOR DISTANCE FROM GRID TO STUDS MATERIALS WIDTH W1 - STUCCO GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 0 RIGID INSULATION/WEATHER BARRIER 2 INCHES ASPHALT IMPREGNATED CRAFT PAPER INCHES METAL LATH INCHES ASSEMBLY THICKNESS FT 10 0 INCHES W2 - STUCCO @ MECH. SHAFT STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES ASSEMBLY THICKNESS 0 FT 7 3/8 INCHES W3 - STONE VENEER GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 11 1/4 INCHES 5/8 INCHES 5/8 INCHES INCHES 1 INCHES 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES 3/4 METAL LATH INCHES 3/4 RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS # 15 FELT 0 W4 - STONE VENEER @ ELEVATOR SHAFT STUDS INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 1 FT 4 5/8 INCHES RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS #15 FELT 0 6 GYPSUM BOARD STUDS SHEATHING WEATHERED STEEL METAL PANEL ASSEMBLY THICKNESS Z-GIRTS W/ RIGID INSULATION/WEATHER BARRIER W5 - WEATHERED STEEL METAL PANEL ASSEMBLY 2 6 INCHES INCHES INCHES 1/4 W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM INCHES RIGID INSULATION/WEATHER BARRIER 2 3/4 INCHES INCHES FIBER CEMENT BOARD VERTICAL PANEL KNIGHT SYSTEM 1/2 ASSEMBLY THICKNESS 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING W7 - BRICK VENEER INCHES RIGID INSULATION/WEATHER BARRIER 2 INCHES BRICK VENEER (SALVAGED) 5/8 INCHES AIR SPACE 3/4 ASSEMBLY THICKNESS 1 FT 2 5/8 INCHES 3 1 0 0 0 0 0 INCHES MORTAR SCRATCH COAT 1/2" INCHES MORTAR SETTING BED 1/2" INCHES 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 1 MORTAR SCRATCH COAT MORTAR SETTING BED 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 0 INCHES 1/2" INCHES 1/2" INCHES 1 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 3 4 2'-0" GYP BD COLUMN ENCLOSURE ZONE FOR RADIANT HEATING PIPES BIOMOTION LAB9'-0" CLG. RE: FINISH SCHEDULE CONC. ON MTL. DECK RE: STRUCT. EXIST CONC STRUCT EXIST CONC STRUCT EXIST MTL PANEL ASSEMBLY TO REMAIN EXIST WINDOW TO REMAIN EXIST CONC STRUCT EXIST CONC FOUNDATION ALUM STOREFRONT CONC COL FOUNDATION AND FOOTING RE: STRUCT CLG RE: FINISH SCHED CONC. ON MTL. DECK RE: STRUCT. R-1 - UL NO P741, 1 HR A501.1A 6 ICU/LSP (E) EXIST CLG A501.1A 7 T.O. STEEL TERRACE 112' - 11 1/2" 3'-8" CONT. MTL. ROOF EDGE, LAPPED OVER PARAPET CONT. WD BLOCKING STUCCO SOFFIT PRE-FINISHED MTL. GUTTER W/ HEAT TRACE CONT STUCCO 'V' REVEAL CONT. STUCCO 'V' REVEAL WINDOW STL. TRUSS, RE: STRUCT PRE-FINISHED 25GA BRAKE MTL. COLLECTOR COVER WINDOW 4" EXIST CLG GYP BD COL ENCLOSURE PAINTED EXTERIOR GYPSUM BOARD SOFFIT. R30 BATT INSUL. 1'-6" 4'-1 1/2" 3'-4" 6'-0" 4'-0" 7'-4" EXIST CLG 8" 8" ENCLOSED COL. W STONE TO 4" ABOVE BOTTOM OF SOFFIT STUCCO ON EXIST. BRICK 5/8" GYB BD ON MTL FURRING CORRIDOR OFFICE 5/8" GYP BD ON 7/8" MTL HAT CHANNELS STERILE SUPPLIES/ CASE CARTS EXIST. OR STANDING SEAM MTL ROOF ON MFG UNDERLAYMENT ON 5/8" GYP SHEATHING, ON MTL DECK, RE: STRUCT STANDING SEAM MTL ROOF ON ICE & WATER SHIELD ON MFG. UNDERLAYMENT ON 5/8" GYPSUM DECK ON MTL. DECK, RE: STRUCT R30 ROCKWOOL BATT INSUL. W6 - FIBER CEMENT BOARD PANEL SYSTEM W1 – STUCCO (2) ROWS OF SNOW FENCE A502.1A 1 A502.1A 3 A502.1A 4 A502.1A 2 A501.1A 2 A501.1A 3 A501.1A 4 2" ADHERED NATRUAL STONE VENEER CAP (COLORADO BUFF) OVERHANG FIELD STONE 1" ALL AROUND CONC BASE STUCCO ON METAL LATH, SLIP SHEET, 2" RIGID INSUL. ON 5/8" SHEATHING ON 3 5/8" MTL STUDS ADHERED NATURAL STONE (SAN MIGUEL) ON 5/8" GYP. BD. SHEATHING 6" X 118 MIL. @ 8" O.C MTL. STUDS, RE:STRUCT @ H/3 & V/3 8'-3 3/8" 1'-10 1/2" 11" 1'-0" 7'-4" STONE ELEMENT 4" VALET A500.1A 1 BIOMOTION LAB CONT. MTL. R3 - UL NO. P741, 2 HR MTL. DECK RE: STRUCT. CONT. WD. BLOCKING 3 1/2" DIA. RIVER ROCK ROOF COVER RECESSED FLOOR @ BIOMOTION LAB R2 - UL NO. P949, 2 HR W5 - WEATHERED STEEL PANEL ASSEMBLY A500.1A 3 A500.1A 15 9 1/4" 4 1/2" OFFICE ADMIN OFFICE TERRACE 23 6" 6" 20 23 20 20 23 20 SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401 JAMB BEYOND ROLLER SHADE ROLLER SHADE 20 20 37 37 37 4'-8" LEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" J J.2 EXIST. BRICK, BEYOND ZONE FOR RADIANT HEATING PIPES STUCCO SOFFIT EXIST CONC STRUCT REUSE EXISTING BRICK CLG. RE: FINISH SCHEDULE CLG, RE: FINISH SCHED CONC. ON MTL. DECK RE: STRUCT. 8" 9'-0" PAINTED EXTERIOR GYPSUM BOARD SOFFIT R30 BATT INSUL. 2" 4'-1 1/2" F.O.S 8" 8" 6 1/2" CONT. STUCCO 'V' REVEAL BIOMOTION W1 – STUCCO W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM (2) ROWS OF SNOW FENCE CONC. ON MTL. DECK RE: STRUCT. A502.1A 1 A502.1A 4 A502.1A 3 A502.1A 2 A501.1A 2 A501.1A 3 A501.1A 4 A501.1A 6 SALVAGED BRICK ROWLOCK SOLDIER COURSE 6" CONCRETE BASE STERILE SUPPLIES/ CASE CARTS BOARD ROOM / LIBRARY 3'-4" 4'-1 1/2" 3'-4" 4'-0" STUCCO ON METAL LATH, SLIP SHEET, 2" RIGID INSUL. ON 5/8" SHEATHING ON 3 5/8" MTL STUDS 11" 1'-0" 8'-4" 7'-4" 1'-10 1/2" CONT. MTL. CONT. WD. BLOCKING 3 1/2" DIA. RIVER ROCK ROOF COVER R2 - UL NO. P949, 2 HR W5 - WEATHERED STEEL PANEL ASSEMBLY 8" 1'-6" A500.1A 3 20 20 20 SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401 JAMB BEYOND 3'-4" 20 ROLLER SHADE ROLLER SHADE 20 20 30 A231.1A 16 SIM ROOF ASSEMBLIES LEGEND MATERIALS THICKNESS R1 - ROOF LEVEL 5, 6 - UL NO. P741, 1 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES R2 - ROOF LEVEL 2 - UL NO. D949, 2 HR RIGID POLYURETHANE INSULATION 5 INCHES VARIES TAPERED INSULATION MEMBRANE INCHES ASSEMBLY THICKNESS 0 FT 5 3/4 INCHES 1/4 3 1/2 1/4 3/8 0 CONCRETE DECK VARIES R3 - ROOF LEVEL 1 - UL NO. P741, 2 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES 3 1/2 1/4 3/8 0 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A BALLAST GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A 000 1' 2' 4' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/2" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/15/2016 2:44:24 PM A223.1A Checker Author WALL SECTIONS - C & S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/2" = 1'-0" 4 WALL SECTION @ 3 & H/J 1/2" = 1'-0" 5 WALL SECTION @ 4 & K/J.2 2 ADD #2 07.16.2015 4 ADD #4 09.21.2015 5 ADD #5 TOV, DFPC 10.20.2015 20 ASI #12 02.03.2016 23 ASI #15 TBD 30 ASI #21 04.25.2016 37 ASI #28 06.15.2016 37 37 01/04/17