Loading...
HomeMy WebLinkAboutA224.1ALEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" K A502.1B 11 CONT. MTL. COPING CONT. WD. BLOCKING EXIST. BRICK VENEER ON EXIST. CONC. STRUCT. EXIST.BRICK EXIST. CONC. PANEL CUT OPENING INTO EXISTING WALL FOR ALUM. SF EXIST. BRICK VENEER ON EXIST. CONC. STRUCT. 5/8" GYP. BOARD ON 7/8" HAT CHANNELS ICU 1 OR (E) SURGICAL LAB EXIST. CONC. STRUCT. ALUM SF. WINDOW CANOPY CLG. RE: FINISH SCHED. MTL. DECK RE: STRUCT. A502.1B 10 A502.1A 8 EXIST. STRUCTURE 8'-0" 4'-0 3/8" EXIST. CLG EXIST.CONCRETE PAVING EXIST.CONCRETE SLAB ON GRADE 1'-2" 3'-2" EXIST. STRUCUTURE SALVAGED BRICK MASONRY WALL W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM A502.1B 14 A502.1B 13 8" 2'-8 1/8" SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401. STUD FURRING R1 - UL NO. P751, 1 HR. 20 20 JAMB BEYOND ROLLER SHADE 20 ROLLER SHADE 20 EXTERIOR WALL ASSEMBLIES LEGEND NOTE: REFER TO PLANS FOR DISTANCE FROM GRID TO STUDS MATERIALS WIDTH W1 - STUCCO GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 0 RIGID INSULATION/WEATHER BARRIER 2 INCHES ASPHALT IMPREGNATED CRAFT PAPER INCHES METAL LATH INCHES ASSEMBLY THICKNESS FT 10 0 INCHES W2 - STUCCO @ MECH. SHAFT STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES ASSEMBLY THICKNESS 0 FT 7 3/8 INCHES W3 - STONE VENEER GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 1 INCHES 3 1/2 INCHES STONE ASSEMBLY THICKNESS 1 FT 2 1/4 INCHES 5/8 INCHES 5/8 INCHES INCHES 1 INCHES 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES 3/4 METAL LATH INCHES 3/4 RIGID INSULATION/WEATHER BARRIER 2 AIR SPACE 1/2 W4 - STONE VENEER @ ELEVATOR SHAFT STUDS INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 1 INCHES 3 1/2 INCHES STONE ASSEMBLY THICKNESS 1 FT 5 5/8 INCHES RIGID INSULATION/WEATHER BARRIER 2 AIR SPACE 1/2 6 GYPSUM BOARD STUDS SHEATHING WEATHERED STEEL METAL PANEL ASSEMBLY THICKNESS Z-GIRTS W/ RIGID INSULATION/WEATHER BARRIER W5 - WEATHERED STEEL METAL PANEL ASSEMBLY 2 6 INCHES INCHES INCHES 1/4 W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM INCHES RIGID INSULATION/WEATHER BARRIER 2 3/4 INCHES INCHES FIBER CEMENT BOARD VERTICAL PANEL KNIGHT SYSTEM 1/2 ASSEMBLY THICKNESS 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING W7 - BRICK VENEER INCHES RIGID INSULATION/WEATHER BARRIER 2 INCHES BRICK VENEER (SALVAGED) 5/8 INCHES AIR SPACE 3/4 ASSEMBLY THICKNESS 1 FT 2 5/8 INCHES 3 1 0 0 0 0 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" K EXIST. WALL W/ BRICK VENEER ICU/ISO SURGICAL LAB EXIST. BRICK VENEER BEYOND EXISTING CONC. SPANDREL EXIST. ROOF ROOF BEYOND EXIST. CONC STRUCT. CONT. MTL COPING CONT. WD BLOCKING WINDOW CANOPY CLG. RE: FINISH SCHED. ALUM SF. EXIST. SOFFIT EXIST. CONC STRUCT. CONC. ON MTL. DECK RE: STRUCT. ALUM. SF BEYOND MTL. DECK RE: STRUCT. RI - UL NO. P741, 1HR EXIST. CEILING OFFICE (E) 5'-4" EXIST. CONC ON CONFORM A502.1A 8 A502.1B 10 A502.1B 18 SIM 10 3/8" FIBER CEMENT BOARD SYSTEM AND INSULATION ON EXISTING CONCRETE STRUCTURE. W6 - FIBER CEMENT BOARD PANEL SYSTEM 20 20 ROLLER SHADE 20 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 8 CONT. MTL COPING CONT. WD BLOCKING R1 -UL NO. P741, 1HR CONC. ON MTL. DECK RE: STRUCT. EXIST. CONC. STRUCT. EXTERIOR FACE OF EXISTING BUILDING EXIST. STANDING SEAM SIDING ON HAT CHANNELS. GYP. BOARD ON COL. ENCLOSURE EXIST. FLOOR EXISTING ROOM EXIST. 4" BRICK EXIST. CEILING EXIST. CONC. STRUCT. EXISTING ROOM EXIST. BRICK CAVITY WALL ASSEMBLY W/ INT. GYP. BOARD FINISH EXIST. WINDOW ICU 2 EXIST. STORAGE SURGICAL LAB CLG RE: FINISH SCHEDULE EXIST. CONC. STRUCT. CLG. RE: FINISH SCHED. 5/8" GYP. BOARD ON 7/8" HAT CHANNELS ALUM. SF. R-20 BATT INSUL. EXIST. CONC. STRUCT. STEEL BEAM RE: STRUCT. STEEL FRAMING RE: STRUCT. EXIST. ROOF 10" 4'-3 1/2" MTL. DECK RE: STRUCT. A502.1B 19 A502.1B 17 TIE-OFF RE: STRUCT. A502.1B 20 A502.1B 16 BEYOND BEYOND A502.1A 8 A502.1B 18 20 ROLLER SHADE 20 ROOF ASSEMBLIES LEGEND MATERIALS THICKNESS R1 - ROOF LEVEL 5, 6 - UL NO. P741, 1 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES R2 - ROOF LEVEL 2 - UL NO. D949, 2 HR RIGID POLYURETHANE INSULATION 5 INCHES VARIES TAPERED INSULATION MEMBRANE INCHES ASSEMBLY THICKNESS 0 FT 5 3/4 INCHES 1/4 3 1/2 1/4 3/8 0 CONCRETE DECK VARIES R3 - ROOF LEVEL 1 - UL NO. P741, 2 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES 3 1/2 1/4 3/8 0 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A BALLAST GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A 000 1' 2' 4' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/2" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 2/11/2016 10:37:20 AM A224.1A Checker Author WALL SECTIONS - C & S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/2" = 1'-0" 6 WALL SECTION @ 6/7 & K 1/2" = 1'-0" 7 WALL SECTION @ 8 & K 1/2" = 1'-0" 8 WALL SECTION @ 8/9 & J 2 ADDENDUM # 2 07.16.2015 5 ADDENDUM # 5 TOV: B15-0185 DFPC ID : 9667 10.20.2015 20 ASI #12 2.3.2016 AND FRAMING AND FRAMING AND FRAMING 01/04/17