Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A225.1A
LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 8 CONT. MTL COPING CONT. WD BLOCKING REMOVE EXIST. ROOF ASSEMBLIES AND PARAPET WALL FLASHING 5/8" GYP. BD BOTH SIDES 3 5/8" MTL STUDS OFFICE EXISTING PASSAGE SURGERY LOCKERS MENS TOILET CORRIDOR 1-COR-1 ALUM SF EXISTING COLUMN COVER R1 - UL NO. P741, 1 HR MTL. DECK RE: STRUCT. STL. FRAMING RE: STRUCT. EXISITING FLOOR EXISITING FLOOR EXISTING CEILING EXISTING CEILING EXISTING CEILING EXISTING CONCRETE SLAB EXISTING CONCRETE STRUCUTURE EXISTING CONCRETE STRUCUTURE CEILING RE: FINISH SCHEDULE EXISTING ROOF A502.1B 22 A502.1A 8 A502.1B 17 CLG RE: RCP 10" EXISTING SHAFT WALL EXISTING ROOF EXISTING PARAPET FIBER CEMENT SOFFIT W6 - FIBER CEMENT BOARD PANEL SYSTEM 7'-9" 4'-11 1/2" TIE OFF. RE: STRUCT W6 - FIBER CEMENT BOARD PANEL SYSTEM W6 - FIBER CEMENT BOARD PANEL SYSTEM 20 20 20 ROLLER SHADE 20 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 8 CONC. PAVING, RE:CIVIL EXIST. FLOOR EXIST. CONC. STRUCT. CONC. ON MTL. DECK RE: STRUCT. CONC. FOUND. WALL RE: STRUCT CONC. SLAB ON GRANULAR FILL RE: STRUCT. 9'-4" EXIST. ROOFING EXIST. STL. STRUCT. EXIST. SOFFIT TO REMAIN EXIST. FLOOR EXIST. STL. STRUCT. EXIST. STL. STRUCT. EXIST. CMU WALL MTL. DECK RE: STRUCT. STL. FRAMING RE: STRUCT. CLG. RE: RCP ALUM STOREFRONT CONT. MTL. COPING CONT. WD. BLOCKING EXIST. CONC. STRUCT. CLG. RE: RCP CLG. RE: RCP CONC. FTG. RE: STRUCT. EXIST. DOOR BEYOND 8" CONC. ON MTL. DECK RE: STRUCT. 5/8" GYP.BOARD ON 2 1/2" MTL. FURRING CONCRETE COLUMN BEYOND CEILING RE: RCP PHYSICAL THERAPY ROOM PROJECT ROOM PATIENT TOILET EXISTING EXISTING R1 - UL NO. P741, 1 HR STUCCO 6'-11" EXIST. GYP BD. ON MTL FURRING EXIST. CEILING EXIST. GYP BD. ON MTL FURRING OPEN TO STRUCTURE, PAINTED FLASHING A501.1A 8 FLASHING W1 – STUCCO A502.1A 8 STUCCO ON 2" RIGID ON CONC. WALL 2" RIGID INSUL. 4" DIA PERFORATED PLASTIC DRAIN PIPE IN ENVELOPE OF PROPERLY GRADED SAND AND GRAVEL WRAPPED IN FILTER FABRIC. DRAIN TO SUMP PUMP OR GRAVITY DISCHARGE. 1'-5" MD STAFF W1 – STUCCO PATIENT / PSP A501.1A 3 A501.1A 4 A501.1A 1 SIM 20 20 20 20 20 20 20 ROLLER SHADE 20 EXTERIOR WALL ASSEMBLIES LEGEND NOTE: REFER TO PLANS FOR DISTANCE FROM GRID TO STUDS MATERIALS WIDTH W1 - STUCCO GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 0 RIGID INSULATION/WEATHER BARRIER 2 INCHES ASPHALT IMPREGNATED CRAFT PAPER INCHES METAL LATH INCHES ASSEMBLY THICKNESS FT 10 0 INCHES W2 - STUCCO @ MECH. SHAFT STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES ASSEMBLY THICKNESS 0 FT 7 3/8 INCHES W3 - STONE VENEER GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 11 1/4 INCHES 5/8 INCHES 5/8 INCHES INCHES 1 INCHES 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES 3/4 METAL LATH INCHES 3/4 RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS # 15 FELT 0 W4 - STONE VENEER @ ELEVATOR SHAFT STUDS INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 1 FT 4 5/8 INCHES RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS #15 FELT 0 6 GYPSUM BOARD STUDS SHEATHING WEATHERED STEEL METAL PANEL ASSEMBLY THICKNESS Z-GIRTS W/ RIGID INSULATION/WEATHER BARRIER W5 - WEATHERED STEEL METAL PANEL ASSEMBLY 2 6 INCHES INCHES INCHES 1/4 W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM INCHES RIGID INSULATION/WEATHER BARRIER 2 3/4 INCHES INCHES FIBER CEMENT BOARD VERTICAL PANEL KNIGHT SYSTEM 1/2 ASSEMBLY THICKNESS 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING W7 - BRICK VENEER INCHES RIGID INSULATION/WEATHER BARRIER 2 INCHES BRICK VENEER (SALVAGED) 5/8 INCHES AIR SPACE 3/4 ASSEMBLY THICKNESS 1 FT 2 5/8 INCHES 3 1 0 0 0 0 0 INCHES MORTAR SCRATCH COAT 1/2" INCHES MORTAR SETTING BED 1/2" INCHES 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 1 MORTAR SCRATCH COAT MORTAR SETTING BED 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 0 INCHES 1/2" INCHES 1/2" INCHES 1 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 8 7 3/4" 3 3/4" CONC. FOOTING RE: STRUCT. 2" RIGID INSUL. CONC. PAVING BEYOND ADHERED NATURAL STONE VENEER ON CONC. EXIST. DOOR BEYOND. EXIST. WINDOW TO REMAIN, BEYOND EXIST. WEATHERED STEEL TO REMAIN, BEYOND CONC. ON MTL. DECK RE: STRUCT. GYP. BD. COLUMN ENCLOSURE CONC. ON MTL. DECK RE: STRUCT. STL. BEAM RE: STRUCT. DUCTS RE: MECH 2HR SHAFTWALL (UL NO. U415 B) 2 1/2" 20GA. C-H STUDS MTL. DECK RE: STRUCT. PAINTED EXTERIOR GYPSUM BOARD SOFFIT CONC. SLAB ON GRANULAR FILL RE: STRUCT. CONC. FOUND. WALL RE: STRUCT. CONT. MTL. GRAVEL STOP CONT. WD. BLOCKING WEATHERIZED METAL PANEL SOFFIT PATIENT ROOM 5 PHYSICAL THERAPY GYM MECH SHAFT 4 3/8" STL. PLATES WELDED TO BEAM FLANGE AND STUDS RE: STRUCT. CLG. RE: RCP R1 - UL NO. P741, 1 HR R30 BATT INSULATION CONC. COLUMN BEYOND BOARD ROOM / TRAINING 5/8" GYP.BD. ON 2 1/2" MTL. STUDS CONC. ON MTL DECK CONC. COL. BEYOND CEILING RE: RCP PHYS OFFICES DRAINAGE BOARD ON 2" RIGID INSULATION ON FLUID APPLIED WATER PROOFING CONC. ON MTL. DECK RE: STRUCT. EXIST. WINDOW TO REMAIN, BEYOND CEILING RE: FINISH SCHED. EXIST. EFIS TO REMAIN 8 PATIENT CLG. RE: RCP W5 - WEATHERED STEEL PANEL ASSEMBLY W1 – STUCCO T.O. STL. 163' - 1 1/2" A500.1A 1 ACCESS LADDER A500.1A 1 A500.1A 6 11 1/8" 3" CONC. PAVING, RE:STRUCT. 2'-8 1/2" 4" DIA PERFORATED PLASTIC DRAIN PIPE IN ENVELOPE OF PROPERLY GRADED SAND AND GRAVEL WRAPPED IN FILTER FABRIC. DRAIN TO SUMP PUMP OR GRAVITY DISCHARGE. 6" R1 - UL NO. P751, 1 HR. W3 – STONE VENEER 20 20 20 20 20 20 20 MIN 2" 37 37 ROOF ASSEMBLIES LEGEND MATERIALS THICKNESS R1 - ROOF LEVEL 5, 6 - UL NO. P741, 1 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES R2 - ROOF LEVEL 2 - UL NO. D949, 2 HR RIGID POLYURETHANE INSULATION 5 INCHES VARIES TAPERED INSULATION MEMBRANE INCHES ASSEMBLY THICKNESS 0 FT 5 3/4 INCHES 1/4 3 1/2 1/4 3/8 0 CONCRETE DECK VARIES R3 - ROOF LEVEL 1 - UL NO. P741, 2 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES 3 1/2 1/4 3/8 0 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A BALLAST GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A 000 1' 2' 4' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/2" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/15/2016 2:44:39 PM A225.1A Checker Author WALL SECTIONS - C & S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/2" = 1'-0" 9 WALL SECTION @ 8/9 & F 1/2" = 1'-0" 10 WALL SECTION @ 4 & A.4 1/2" = 1'-0" 11 WALL SECTION @ 8 & A/Aa.6 2 ADD #2 07.16.2015 5 ADD #5 TOV, DFPC 10.20.2015 20 ASI #12 02.03.2016 37 ASI #28 06.15.2016 37 37 01/04/17