Loading...
HomeMy WebLinkAboutA226.1ALEVEL 1 100' - 0" LEVEL 2 114' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" LEVEL 3A(1978) 121' - 0" A Aa.6 Aa.1 CONT. MTL. ROOF EDGE CONT. WD. BLOCKING EXIST. GUARDRAIL BEYOND WALL BEYOND 1/2" BITUMINOUS FIBER EXPANSION JOINT FILLER CONCRETE STEPS RE: CIVIL PAINTED EXTERIOR GYPSUM BOARD SOFFIT STL. FRAMING RE. STRUCTURE PARAPET OF EXIST. BUILDING STL. FRAMING RE. STRUCT. WEATHERIZED STEEL SOFFIT PANEL BY MFG. TO MATCH WALL ASSEMBLY MECHANICAL SHAFT MTL. DECK RE: STRUCT. DUCT. RE: MECH FACE OF EXTERIOR WALL @ EXIST. BLDG. STL.. STRUCT. BEYOND EXIST. ROOF DUCT. RE: MECH R1 - UL NO. P751, 1 HR. W1 – STUCCO W5 - WEATHERED STEEL PANEL ASSEMBLY W5 - WEATHERED STEEL PANEL ASSEMBLY A500.1A 6 A500.1A 1 A501.1A 9 WEATHERIZED STEEL SOFFIT PANEL BY MFG. TO MATCH WALL ASSEMBLY BELLOWS EXPANSION JOINT 3" T.O. CONC. 92'-0" A500.1A 6 HANDRAIL. 1/2" RADIUS NOSING TYPICAL. 1'-0" 1'-0" 3'-0" CORE DRILL & NON SHRINK GROUT VERT. POSTS, 8" EMBEDMENT TYP. CONCRETE PAVING RE: CIVIL 3'-0" TIE OFF. RE: STRUCT. 20 20 LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" Aa Aa.1 3'-4" 3'-2 1/4" WINDOW CANOPY ALUM SF CLG. RE: RCP STONE HEAD ALUM SF CONC. ON MTL. DECK RE: STRUCT. CONC. ON MTL. DECK RE: STRUCT. ZONE FOR HEATING PIPE ALUM SF CONC. ON MTL. DECK RE: STRUCT. PAINTED EXTERIOR GYPSUM BOARD SOFFIT. STL. STRUCT. RE: STRUCT. CURTAIN WALL GLAZING STONE SILL ADHERED NATURAL STONE VENEER TO CONC. FOUND. WALL 5/8" GYP. BOARD ON 3 5/8" MTL. STUDS @ 16" O.C. ON 2" RIGID INSUL. BRICK LEDGE, RE:STRUCT CONC. FOUND WALL RE: STRUCT. CONC. ON MTL. DECK RE: STRUCT. CONC. SLAB RE: STRUCT. STONE SILL PHYS OFFICE 5- PATIENT PATIENT ROOM 3 EXERCISE AREA CONT. WD. BLOCKING CONT. MTL. COPING STONE COLUMN ENCLOSURE BEYOND STONE CAP BEYOND CONFERENCE ROOM B CLG. RE: RCP 20'-8" 10" FLASHING R1 - UL NO. P751, 1 HR. W3 – STONE VENEER W6 - FIBER CEMENT BOARD PANEL SYSTEM A503.1A 7 A501.1A 2 A503.1A 2 11'-0" 5'-8" 5'-0" A502.1A 8 A502.1B 10 A500.1A 6 A501.1A 10 SIM A503.1A 8 4'-4" ADDITIONAL 6" STUDS TO RECESS STOREFRONT 6'-11" 5'-8 3/4" 3'-4" A503.1A 9 W5 - WEATHERED STEEL PANEL ASSEMBLY W5 - WEATHERED STEEL PANEL ASSEMBLY 3" 1'-10" 2'-1 3/8" ROLLER-SHADE CLG. RE: RCP 3'-0" Aaa 5'-0" LANDSCAPING 8" 3'-8" 7" 7" 1'-4" 10" 2" A500.1A 10 SIM A500.1A 9 SIM 2'-7 3/8" 7 3/8" 8" 2'-8" SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401 STUD FURRING 3'-4" SILL. ALIGN TOP SURFACE WITH BOTT OF MULLION. 1/2" OVERHANG. RE: 19/I401 W1 – STUCCO W5 - WEATHERED STEEL PANEL ASSEMBLY 20 20 R30 BATT INSULATION 20 JAMB BEYOND JAMB BEYOND STUD FURRING ROLLER SHADE 20 ROLLER SHADE 20 ROLLER SHADE 20 PAINTED GYP BD. SOFFIT 20 PAINTED GYP BD. SOFFIT ROLLER SHADE 8" 37 37 1'-5" EXTERIOR WALL ASSEMBLIES LEGEND NOTE: REFER TO PLANS FOR DISTANCE FROM GRID TO STUDS MATERIALS WIDTH W1 - STUCCO GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 0 RIGID INSULATION/WEATHER BARRIER 2 INCHES ASPHALT IMPREGNATED CRAFT PAPER INCHES METAL LATH INCHES ASSEMBLY THICKNESS FT 10 0 INCHES W2 - STUCCO @ MECH. SHAFT STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES ASSEMBLY THICKNESS 0 FT 7 3/8 INCHES W3 - STONE VENEER GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 11 1/4 INCHES 5/8 INCHES 5/8 INCHES INCHES 1 INCHES 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING 3-COAT STUCCO INCHES 3/4 METAL LATH INCHES 3/4 RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS # 15 FELT 0 W4 - STONE VENEER @ ELEVATOR SHAFT STUDS INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING INCHES 0 INCHES 2.5 LB METAL LATH ASSEMBLY THICKNESS 1 FT 4 5/8 INCHES RIGID INSULATION/WEATHER BARRIER 2 2 LAYERS #15 FELT 0 6 GYPSUM BOARD STUDS SHEATHING WEATHERED STEEL METAL PANEL ASSEMBLY THICKNESS Z-GIRTS W/ RIGID INSULATION/WEATHER BARRIER W5 - WEATHERED STEEL METAL PANEL ASSEMBLY 2 6 INCHES INCHES INCHES 1/4 W6 - FIBER CEMENT BOARD VERTICAL PANEL SYSTEM INCHES RIGID INSULATION/WEATHER BARRIER 2 3/4 INCHES INCHES FIBER CEMENT BOARD VERTICAL PANEL KNIGHT SYSTEM 1/2 ASSEMBLY THICKNESS 0 FT 10 1/2 INCHES GYPSUM BOARD 5/8 INCHES STUDS 6 INCHES 5/8 INCHES SHEATHING W7 - BRICK VENEER INCHES RIGID INSULATION/WEATHER BARRIER 2 INCHES BRICK VENEER (SALVAGED) 5/8 INCHES AIR SPACE 3/4 ASSEMBLY THICKNESS 1 FT 2 5/8 INCHES 3 1 0 0 0 0 0 INCHES MORTAR SCRATCH COAT 1/2" INCHES MORTAR SETTING BED 1/2" INCHES 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 1 MORTAR SCRATCH COAT MORTAR SETTING BED 1 1/2" NOMINAL FULLY ADHERED NATURAL STONE VENEER 0 INCHES 1/2" INCHES 1/2" INCHES 1 ROOF ASSEMBLIES LEGEND MATERIALS THICKNESS R1 - ROOF LEVEL 5, 6 - UL NO. P741, 1 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES R2 - ROOF LEVEL 2 - UL NO. D949, 2 HR RIGID POLYURETHANE INSULATION 5 INCHES VARIES TAPERED INSULATION MEMBRANE INCHES ASSEMBLY THICKNESS 0 FT 5 3/4 INCHES 1/4 3 1/2 1/4 3/8 0 CONCRETE DECK VARIES R3 - ROOF LEVEL 1 - UL NO. P741, 2 HR METAL DECKING INCHES 5 INCHES RIGID POLYURETHANE INSULATION TAPERED INSULATION VARIES DENSDECK INCHES MEMBRANE INCHES ASSEMBLY THICKNESS FT 9 INCHES 3 1/2 1/4 3/8 0 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A BALLAST GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A GYPSUM SHEATHING INCHES 5/8 SELF-ADHERING AIR BARRIER AND VAPOR RETARDER N/A 000 1' 2' 4' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/2" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/15/2016 2:44:50 PM A226.1A Checker Author WALL SECTIONS - C & S 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/2" = 1'-0" 12 WALL SECTION @ Aa.6 & 8 1/2" = 1'-0" 13 WALL SECITON @ Aa & 6/7 2 ADD #2 07.16.2015 5 ADD #5 TOV, DFPC 10.20.2015 20 ASI #12 02.03.2016 37 ASI #28 06.15.2016 37 37 01/04/17