Loading...
HomeMy WebLinkAboutA302.1AF.V.C. (E) REF. UP F.E. UP UP LEVEL 1 100' - 0" LEVEL 2 114' - 0" LOWER LEVEL 86' - 0" LEVEL 3 127' - 4" LEVEL 4 140' - 8" LEVEL 05 153' - 5 1/2" 8 Ae2001 T.O STEEL 164' - 0" EXISTING STAIR CONFERENCE EXIST. ROOF PHYSICAL THERAPY OFFICE EXIST. FURRING TYP. @ CONC. STAIR WALL DRESSING STAIR LANDING 7" CONC. ON MTL.DECK EQUIP. STOR. ON CALL LIBRARY STAFF LOUNGE 13'-4" NEW MTL. PAN STAIR W/ CONC. INFILL 12R. @ 7" = 6'-11 1/2" 12 R. @ 7" = 6'-4 1/2" 13'-4 1/2" NEW MTL. PAN STAIR W/ CONC. INFILL 5/8" GYP. BD. ON MTL STUD 12 R. @ 7" = 6'-11 3/4" 6'-4 3/4" 5/8" GYP.BD. ON MTL. STUD W1 – STUCCO W1 – STUCCO R1 - UL NO. P751, 1 HR. 8'-8" R1 - UL NO. P751, 1 HR. WALL BEYOND T.O STL. @ ELEVATOR 166' - 9" REPLACE EXIST GYP BD ON FURRING AS REQUIRED BY STAIR EXTENSION A501.1A 9 OPP A501.1A 1 SIM 8 E D C Ae2001 20 A230.1A 21 A230.1A 1 A302.1A 1'-1" 4 1/4" UP VIF 5'-0" 2" ELEVATOR #5 ELEVATOR #2 STAIR C EXISTING 2 HR RATED PARTITION 8" 8 E D C Ae2001 20 A230.1A 21 A230.1A 1 A302.1A 3'-11 1/2" 3'-11 1/2" 5'-0" ELEVATOR #5 HOUSE KEEPING STAIR C 8'-0 1/2" 2" 6'-11 1/2" 22'-10 1/2" 6 3/8" 2" 10'-8 5/8" 1'-3 3/8" 11'-11 3/8" STAFF LOUNGE 2 HR RATED WALL 3 5/8" STUD WITH 2 LAYERS OF GYP. BD. EA. SIDE W1 – STUCCO ALIGN INTERIOR FACE OF GYP BD WITH INSIDE FACE OF EXIST GYP. BD. BELOW. 7 A302.1A SIM 8 E D C 20 A230.1A 21 A230.1A 1 A302.1A 10" ELEVATOR MACHINE ROOM ELEVATOR CONTROLLER 1'-1" 12'-0" 3'-0" 5'-1" 10" DASHED LINES INDICATE LINE OF HOISTWAY BELOW SLAB EDGE 8'-10 1/2" 2" 10'-7" 19'-10" 10 T. @ 11" = 9'-2" 11 T. @ 11" = 10'-1" 7" 6 1/2" VERTICAL LADDER STAIR C DN 7 A302.1A W1 – STUCCO 6 A302.1A WALL MOUNTED HANDRAIL LEVEL 05 153' - 5 1/2"3'-6" 2'-0" 3'-0" 6 A302.1A LEVEL 05 8200' - 4 1/4" C LEVEL 05 153' - 5 1/2" T.O STEEL 164' - 0" STAIR LANDING WALL BEYOND 3'-6" 1'-0" TOP OF RUNG FLUSH W/ ROOF LEVEL 05 8200' - 4 1/4" 8 8 1'-5" THRESHOLD SET IN BED OF SEALANT ROOF MEMBRANE RIGID INSULATION OVER 5/8" EXTERIOR GRADE GYPSUM ON 3" METAL DECK RE: STRUCT. EDGE SEALANT METAL FLASHING CONCRETE CURB 7" CONC. ON 3" DECK RE: STRUCT. WALKWAY ROOF PAD MEMBRANE FLASHING THRESHOLD SET IN BED OF SEALANT PTD. HOLLOW METAL DOOR 154' - 0 1/2" T.O. CONCRETE 153' - 5 1/2" T.O. STEEL NEW METAL PAN STAIR 000 2' 4' 8' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/4" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 10/22/2015 12:55:07 PM A302.1A Checker Author ENLARGED PLANS & SECTIONS - VERTICAL CIRCULATION 05/28/2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1/4" = 1'-0" 1 SECTION @ SOUTH(C) STAIR 1/4" = 1'-0" 2 ENLARGED SOUTH(C) STAIR & ELEVATOR #5 PLAN - LEVEL THREE 1/4" = 1'-0" 3 ENLARGED SOUTH(C) STAIR & ELEVATOR #5 PLAN - LEVEL FOUR 1/4" = 1'-0" 4 ENLARGED SOUTH(C) STAIR & ELEVATOR PLAN - LEVEL FIVE 1/4" = 1'-0" 5 TYP. VERTICAL LADDER - ELEVATION 1/4" = 1'-0" 6 TYP. VERTICAL LADDER - SECTION 1 1/2" = 1'-0" 7 DOOR SILL @ SOUTH STAIR ROOF ACCESS 2 ADDENDUM # 2 07.16.2015 5 ADDENDUM #5 TOV: B15-0185 DFPC ID : 9667 10.20.2015 01/04/17